DISPOSAL, WORKS CONSTRUCTION PERMIT
Permission is hereby granted Daigle-Enterprises, Inc. ---- -
to(Upgrade)an Individual Sewage Disposal System.
at No 45 BEECHWOOD DRIVE ------------------------------------
as shown on the application for Disposal Works Construction Permit No. BBP-2016-021 Dated June 28,2016
------------------------ ------------------------------
BOARD°------------ H ---------------
---------------
Issued On: Jun-28-2016 OF HEALTH
3
0 Application for Septic Disposal System
l�C U t
�...
TODAY'S DATE
Construction Permit -- TOWN OF
Rett
NORTH ANDOVER, MA 01845 $1 °o0-copy p
Important: Application is hereby made for a permit to:
When filling out ❑C nstruct a new on-site sewage disposal system*
forms on the
computer,use Repair or replace an existing on-site sewage disposal system'*
only the tab key
to move your El Repair or replace an existing system component–What?
cursor-do not
use the return A. Facility Information
key.
Address or Lot#
City/Town
!e`er 2.-*TYPE OF SEP IC SYSTEM*;
➢ ❑ Pump EgGravity(choose one)
***!f pump sy 4 tem, attach copy of electrical permit to application***
onventional System (pipe and stone system)
Infiltrator or Biodiffuser(Gravel-Less) (Attach a copy of your certification to install this type of system.)
Y ❑ Pressure Distribution S.A.S.(No D-Box)
Y ❑ Pressure Dosed(D-Box Present)S.A.S.
Y ❑,Does the system require an effluent filter? Yes No
If yes, does plan specify make and model of filter? YES =(no further info. needed)
NO=(installer must specify brand of filter before DWC issuance)
What is the Make? What is the Model?_..—-------
2. Owner Information
yf �
�r«ar )'L_.
Name
d M
– -- _---._.._..--
City/Town different from above) --. State Zip Code
Ad ress if �
Y
Email address Telephone Number
3, Installer Information i
Name N8 deoef6C_o_m�pany
Address Y __..__..-----___—
City/Town State Zip Code
',/c ` _ Z ' 41'3.;, -
Telephone Number(Cell Phone#if possible please)
4. Designer Information
Name� C1 4A �' -— Na
e of Company
Cc�t;�J w"+r'+it�t frJ1 as
Address
City/Town State Zip Code
&' 3 V3 ITS t,__c
Telephone Number(Best#to Reach)
Application for Disposal System Construction Permit•Page 1 of 2
Application for Septic Disposal System
TODAY'S DATE
Construction Permit - TOWN OF
$350.00-Full Repair
NORTH ANDOVER, MA 01845
$175.00-Component
PAGE 2 OF 2
A. Facility Information continued....
5. Type of Building: ❑Residential Dwelling orgpmmercial
B. Agreement
The undersigned agrees to ensure the construction and maintenance of the afore-described
on-site sewage disposal system in accordance with the provisions of Title 5 of the
Environmental Code, as well as the Local Subsurface Disposal Regulations for the Town of
North Andover. 1 understand that until a final Certificate of Compliance has been issued by
this Boa
,Mtof Health, the "ns led system is not approved.
�' 0 Na _ Date —
Ap i tion r d By: (Board of Health Representative),,,
e
ppl' ation Disapproved for the following reasons:
For Office Use Only:
Z Fee Attacheda Yes" No
2. PtojectManaget Ohligatiora Fotm Attached? Yes No
3. Purnp S sv tern? If so,Attach copy ofElec&c: it 'etxnit Yes No
Applicarst received copy of
"Electrical Inspection Notes for Septic Systems" Yes No
I-landout?
4. Reviewed approval letter, all paper-work received? Yes No
Missing._
5. Foundation As-Built?(new construction only). Yes No
(Same scale as approved plan)
6. Floor Plans?(new construction only): Yes No
Application for Disposal System Construction Permit-Page 2 of 2
SEPTIC SYSTEM INSTALLER PROJECT MANAGEMENT OBLIGATIONS
As the North Andover licensed installer for the construction for the septic system for the property at:
............. For pla -tx
(Address of septic system) i� / ns bv (Engineer)
Relative to the application of 416, <'
(Installer's name) And dated
qurigu i i(ate
Dated a L'9
date) With revisions dated 9, 46,
(Last revi"I'd date)
I understand the following obligations for management of this project:
1. As the installer, I am obligated to obtain all permits and Board of Health approved plans pj•ior to
performing any work on a site. I must have the approved plans and the permit on site when any work is
being done.
2. As the installer, I inust call for any and all inspections. If homeowner, contractor,project manager, or any
other person not associated with my company schedules an inspection and the system is not ready, then
item three shall be applicable.
3. As the installer, I am required to have the necessary work completed prior to the applicable inspections as
indicated below. I understand that requesting an inspection,without completion of the items in accordance
with Title 5 and the Board of Health Regulations may result in a $50.00 fine being levied against me and/or
my compapL.
a. Bottom of Bed—Generally, this is the first (1') inspection unless there is a retaining wall, which
should be done first. The installer must request the inspection but does not have to be present.
b. Final Construction InsDection---Engineer must first do their inspection for elevations, ties, etc.
As-built of verbal OK (or e-mail to: liealthdct)t((t),townoft-i(�)rtliandover.c(-)iii) from the engineer must
be submitted to the Board of Health, after which installer calls for an inspection time. Installer must
be present for this 'inspection. With a pump system, all electrical work must be ready and able to
cause pump to work and alarm to function.
c. Final Grade—Installer must request inspection when all grading is complete. Installer does not
have to be on-site.
4. As the installer, I understand that only I may perform the work (other than simple e,%vaiwfion)and I am required
to complete the installation of the system identified in the attached application for installation. I further
understand that work done by others unlicensed to install septic systems in North Andover can constitute
reasons for denial of the systein and/or revocation or suspension of my license to operate in the Town of
North Andover significant fines to all persons involved are also possible.
5. As the installer, I understand that I must be on-site during the performance of the following construction
steps:
a. Determination that the proper elevation of the excavation has been reached
b. Inspection of the sand and stone to be used
c. Final inspection by Board of I-Jealth staff or consultant.
d Installation of tank, D-Box,pipes, stone, vent,pump chamber, retaining wall and other
components.
6. As the installer, I understand that I am solely responsible for the installation of the system as per the
approved 12Tans. No instructions by the homeowner, aCwcral c(Atractor, or any other persons shall absolve
me of this obligation.
Undersigned Licensed Septic Installer: (I'oda) I..)atc
TT7"_t1n6--Print.-) (NatnV---Signed)