Loading...
HomeMy WebLinkAboutCertificate of Compliance - 73 RIVERVIEW STREET 12/5/2016 J • PUBLIC HEALTH DEPARTMENT Town of North Andover Community.and Economic Development Division CERTIFICATE OF COMPLIANCE As of: !, SN This is to certify that the individual subsurface disposal system received a SATISFACTORY INSPECTION of the: Repair of D-Box and risers By: John DiVincenzo At: 73 Riverview Street Ma p 072,0 Lot 0001 North Andover, MA 01845 'The Issuance of this,ce ificato shall not be construed as a guarantee that the system will f motion satisfactorily. 4ichele Grant = _=' Public Health Agent 120 Main Si.,North Andover,Massachusetts 01845 Phone 978.688.9540 Fax 978.688.9542 Web www.northandoverma.gov 1 RPM • 1 North Andover Health Department fommunity and Economic Development Division ONSITE WASTEWATER SYSTEM CONSTRUCTION NOTES LOCATION INFORMATION ADDRESS: 73 Riverview St. MAP: 072.0 LOT: 0001 INSTALLER: John DiVincenzo DESIGNER: PLAN DATE: BOH APPROVAL DATE ON PLAN: INSPECTIONS D-box & risers: DATE OF BED BOTTOM INSPECTION: `°' u.F DATE OF FINAL CONSTRUCTION INSPECTION: DATE OF FINAL GRADE INSPECTION: SITE CONDITIONS ❑ Contractor reports any changes to design plan ❑ Existing septic tank properly abandoned ❑ Internal plumbing all to one building sewer ❑ Topography not appreciably altered Comments: SEPTIC TANK ❑ Building sewer in continuous grade, on compacted firm base ❑ Cleanouts per plan ❑ Bottom of tank hole has 6" stone base ❑ Weep hole plugged ❑ 1500 gallon flank has been installed H-10 loading ❑ Monolithic tank construction ❑ Water tightness of tank has been achieved by visual testing ❑ Inlet tee installed, centered under access port ❑ Outlet tee installed, centered under access port (gas baffle/effluent filter) ❑ inch cover to within 6" of finish grade installed over one access port ❑ Hydraulic cement around inlet & outlet Comments: PUMP CHAMBER ❑ Bottom of tank hole has 6" stone base ❑ Weep hole plugged ❑ 1500 gallon Pump Chamber installed ❑ H-10 loading F-1 Monolithic tank construction ❑ Inlet tee installed, centered under access port ❑ Pump(s) installed on stable base ❑ Alarm float working ❑ Pump On/Off floats working F-1 Separate on/off floats ❑ Drain hole in pressure line ❑ cover at final grade installed over pump access port ❑ Water tightness of tank has been achieved by testing ❑ Hydraulic cement around inlet & outlet Comments: CONTROLPANEL F-1 Alarm & Pump are on separate circuits ❑ Alarm sounds when float is tripped ❑ Location of control panel: basement ❑ Alarm signal located inside: basement Comments: DISTRIBUTION-BOX ............ LF7j/ installed on stable stone base nV H-20 D-Box ,R Ej Inlet tee (if pumped or >0.08'/foot) /Hydraulic cement around inlet & outlets /Observed even distribution M Speed levelers provided (not required) ❑ hedule 40 PVC Pipe Comments: 0 V