Loading...
HomeMy WebLinkAboutBuilding Permit # 1/18/2017 ` ~" No. Plans Submittedx Plans Waived❑ Certified Plot Plan,% Stamped Planse TYPE OF SEWERAGE DISPOSAL Public Sewer ❑ TanniugfMassagetBody Arc ❑ swimming Pools ❑ Welt ❑ Tobacco Sales ❑ Food Packaging/Sales ❑ Private(septic tank,etc. Permanent Dwnpster on Site ❑ THE FOLLOWING SECTIONS FOR OFFICE USE ONLY INTERDEPARTMENTAL SIGN OFF e U FORM PLANNING&DEVELOPMENT Reviewed On tJ L Si nature COMMENTS t�llj �LV� I6'1fl �I �� l CONSERVATION Reviewed on f /t J j 7 Signature COMMENTS r � f HEALTH Reviewed on � ' I� �UI� SignaiJ.��f� COMMENTS. LD Zoning Board of Appeals:Variance,Petition No: Zoning Decision/receipt submitted yes Planning Board Decision: Comments Conservation Decision: Comments Wafer&Sewer CenneGtlonlSignature&Date �� � t� Driveway Permit DPW Town Engineer:Signature: Located 384 Osgood Street SIRE DEPARTMENT Temp Qumpster onaite yes no �� a LQeated at 124 Main Street Fire Department s�gnaturetda#e .: COMMENTS ' Town of "°R " 6 Andover Q No. i7 - h * ver,Mass, !�� / ZD/ y_�Qq tocrci�Gw@w.cw 47' U BOARD OF HEALTH Food/Kitchen PERMIT T ILD n Septic System THIS CERTIFIES THAT 119.. .�.�� •• .............................. BUILDING INSPECTOR CV-61 )� Foundation has permission to erect..........................buildings on. ... .... ......�••�/ 1-0 t ///►►► '0 Rough tobe occupied as..... ......011....... ............................................................................. Chimney provided that the person accepting this permit shall in every respect conform to the terms of the application Final on file in this office,and to the provisions of the Codes and By-Laws relating to the Inspection,Alteration and Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR Rough VIOLATION of the Zoning or Building Regulations Voids this Permit. u�+ Final PERMIT EXPIRES I MONTHS ELECTRICAL INSPECTOR., LESS CONSTR Rough Service .. .. ..... .... .. .......... ...... Final BUILDING I ECTO GAS INSPECTOR occupancy Permit Required to Occupy Bu Rough Display in a Conspicuous Place on the Premises—Do Not Remove Final No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. Burner Street No. Smoke Det. Property HERS Unknown Rating Type: Projected Rating Certified Energy Rater: Eric Wilder 37 Wellington Way Rating Date: 1/17/2017 Rating Number: MARegistry IRatingw I s° � - �i��i�'iq°iati Estimated Annual Energy Cost N.Andover, : _ Projected, : uta �k Nam tit1� 14' �U �: �. use MMBtu cost Percent HERS Index: 52 _ _ Heating 37.8 $1191 46% Generallnformation � Cooling 6.9 $97 4% Hot Water 4.2 $215 8% Conditioned Area 2777 sq.ft. House Type Single-family detached Lights/Appliances 23.6 $896 35% Conditioned Volume 24378 cubic ft. Foundation More than one type photovoltaics -0.0 $-0 -0% Bedrooms 4 Service Charges $168 7% Total 72.5 $2567 100% Mechanical Systems Features Heating: Fuel-fired air distribution,Natural gas,96.0 AFUE. Criteria Cooling: Air conditioner,Electric,13.0 SEER. Water Heating: Instant water heater,Natural gas,0.97 EF,0.0 Gal. This home meets or exceeds the minimum criteria for the following: Duct Leakage to Outside 80.00 CFM25. Ventilation System Exhaust Only:60 cfm,21.0 watts. Programmable Thermostat Heat=Yes;Cool=Yes Building Shell Features Ceiling Flat R-37.0 Slab None Sealed Attic NA Exposed Floor R-30.0 Vaulted Ceiling R-32.5 Window Type U-Value:0.300,SHGC:0.280 Above Grade Watts R-21.0 Infiltration Rate Htg:3.00 Clg:3.00 ACH50 Foundation Walls R-0.0 Method Blower door test Eric Wilder CLEAResult Lights and Appliance Features 50 Washington St. Percent Interior Lighting 100.00 Range/Oven Fuel Natural gas Westborough,MA 01581 Percent Garage Lighting 100.00 Clothes Dryer Fuel Electric 508.328-2760 Refrigerator(kWh/yr) 557 Clothes Dryer EF 3.01 1998-184 Dishwasher(kWh/yr) 270 Ceiling Fan(cfm/Watt) 0.00 9901142 REM/Rate-lFestale n6 gar Energy Aaialysis andlRadng Saftware v'l 4.63 �J This information does not constitute any warranty of energy cost or savings.(D 1985.2016 Noresco,Boulder,Colorado. The Home Energy Rating Standard Disclosure for this home is available from the rating provider. Enter construction cost for fee cal- North Andover Fee Calculation Construction Cost $ 295,000.00 m $ $ 3,540.00 Plumbing Fee $ 442.50 Gas Fee 100 comm. $ 100.00 Electrical Fee $ 442.50 Total fees collected $ 4,525.00 Foundation 100 37 Wellington Way 721-2017 on 1/M2017 single family home 'The Commonwealth of Massachusetts Department oflndusi ialAceidents v, 1 Congress street,suite 100 Boston,MA 02114-2017 www.mass gov/dia • Worliers'Compensation Insurance Affidavit:Builders/Contractors/Electricians/PIumbers. TO BE RILED WITH THE PERD4ITTING AUTHORITY. PleasePriut Legib Applicant Information /� ly Name(BusinessJorganintionnndividual): C� kl t-t )C�1 D��l'�.�,r °oc- Address: 5#11) rt1 'g4r– .,+ CitylState/Zip: t)— Phone N-0 Areyau au employer?Check the appivpriate box: Type of project(faquired): 1.�Sam aempIoyerwifh • employees(full and/or port-time}.* 7.-9Now construction 2.�T azn a sole proprietor or partuorshtp ardhave no employees working for me in S.l![A Remodeling any capacity.iNo workers'comp.insurance raquired.] 0. ❑Demolition 3.QlunahomeownerdoingaIlvorkmysel£INoworkers'carne.-insuracee quked.jt 10 Q Building addition 4.❑Ism a homeowner and will be hiring contractors in conduct all work an my property.Swill 11❑Electrical repairs or additions ensure that all contractors either have vrorkers'compensation insurance orate sole proarietors with no employces. 12:Q Plumbing repairs or additions 5.❑I am agenand contractor and Ihava hired the sub-contractors listed onthe attached sheet. 13:0 Roof repairs These sub_ccnha,,mrshave eiiaployees andhave workus'wrap.itarecace.t 14.Q Other - 6 We are a corporation and irs,officers have exercised theirright of'oxemption perMGS,n. X 153,§I{4},andwehavenq employap.[Iioworkers'cornp.hssumncerequired.] "Any applicantthat checks box#1 must also fill outthe sectionhelovishowing thsirwmrkers compensationpolicyinformation. t Idameawnerswfio sufimifkhis aff'tdaeit irdicatingthey ora doing all work end then biro autsido conhactoss must sgbmitanew affid vit indicating such. #Contractors that aheckthig box must atteciadan additional sheetshowingtire namo of the sub-contractors and state whether ornotthose entities have employecs.Sfiha sub-corilraclors hav n employces,lliey mast provide their workers'comp.policy number. - fain an employer Mat is pros lding ivorkers'compensation insurance for my employees.'Beloiv is tlzep'011 aIt job site information. Insurance Company Name: Policy#or Self-ins.Lic.#: Expnation Data. fob Site Address: City/StafelZip: Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to senate coverage as required under MGL a.152,y§25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the office of Investigations of the DIA for insurance coverage verification. ,T d0 lzel'eby CCFtIf Under'the pQins and peP2altieS O,f perjury that the infol'mat[on prowled ab V2 is trite and correct. Silrnature�+' t p hone Do not write in this area,to be completed by city or town afficiaL City or Town: - Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Trnvn Cleric 4.Electrical Inspector 5.Plumbing Inspector 6.Other Phone Contact Person: #: .....11lr11,y� \off— fConsumerAffarrs&Bus3nessEegiafi- i _ Massachusetts Department of Public Safety -� ... DME IMPROVEMENT CONTRACTOR Board of Building Regulations and Standards F– registration: 164829 Typo' License:CSFA-102931 cxpira0on: 1111912017, Private Corporation Construction Supervisor 1&2 `^ � Family , MESSINA DEVELOPMENT COMPANY INC. ROBERT A MESSINA 277 WASHINGTON ST ROBERT MESSINA GROVELAND MA 01834 -- 277 WASHINGTON ST g -� GROVELAND,MA 01834 - Underseeretarp nn,, Expiration: Commissioner 08131/2018 i71�1 Boise cescade Triple 1-314"x 11-114"VERSA-LAMO 2.0 2800 DF Floor BeamlFB01 Dry 1 span No cantilevers 10112 slope January 15,2017 19:10:30 BG CALCI Design Report Build 5684 File Name: New—Col-37—Wellington—Way Job Name: New Colonial Home Description:Designs1FB01 Address: Lot 6,#37 Wellington Way Specifier: Floor/Roof Support Beam City,State,Zip:North Andover,MA 01845 Designer: KK Customer: Company: KDK Design Code reports: ESR-1040 Misc: See Attic Floor Framing tz-as-oo 61 eo Total Horizontal Product Length=12-06-00 Reaction Summary(Down/Uplift)(lbs) Bearing Live Dead Snow Wind Roof Live BO,3-1/2" 4,81210 1,40710 81,3-1/2" 4,81210 1,407/0 Live Dead Snow Wind Roof Live Trib. Load Summary Tag Descri tionLoad Type Ref. Start End 100% 90% 115% 160% 125% 1 Attic Floor load Unf.Area(Ib/ft"2) L 00-00-00 12-06-00 30 10 07-00-00 2 Roof Load Unf.Area(Ib/V2) L 00-00-00 12-06-00 40 10 14-00-00 Controls Summary Value %Allowable Duration Case Location_ Pos.Moment 18,038 ft-lbs 69.3% 100% 1 06-03-00 End Shear 4,997 lbs 44.5% 100% 1 01-02-12 Total Load Deft. U382(0.378") 62.8% n/a 1 06-03-00 Live Load Defl. Ll494(0.297') 72.8% n/a 2 06-03-00 Max Defl. 0.378" 37.8°! n/a 1 06-03-00 Span/Depth 12.8 n/a n/a 0 00-00-00 %Allow I Allow Bearing Supports Dim,(Lx W) Value Support Member Material BO Post 3-1/2"x 3-112" 6,220 Has n/a 67.M. Unspecified 81 Post 3.1/2"x 3-1/2" 6,220 lbs n/a 67.7% Unspecified Cautions Member is not fully supported at post BO. A connector is required at this bearing. Member is not fully supported at post B1. A connector is required at this bearing. Notes Design meets Code minimum(0240)Total load deflection criteria. Design meets Code minimum(L/360)Live load deflection criteria- �SO Design meets arbitrary(T')Maximum total load deflection criteria. Calculations assume member is fully braced- Design based on Dry Service Condition. S#VC�o� OA 0�54�OF Page 1 of 2 {?1�t Boise Cascade Triple 1-3/4"x 11-1/4"VERSA-LAW 2.0 2800 DF Floor BeamlF13O1 '.. Dry 1 span I No cantilevers 0/12 slope January 15,2017 19:10:30 BC CALC@ Design Report Build 5684 File Name: New—Col-37 Wellington_Way Job Name: New Colonial Home Description:Designs1FB01 Address: Lot 6,#37 Wellington Way Specifier: Floor/Roof Support Beam City,State,Zip:North Andover,MA 01845 Designer: KK Customer: Company: KDK Design Code reports: ESR-1040 Misc: See Attic Floor Framing Connection Diagram Disclosure t�d Completeness and accuracy of input must b , be verified by anyone who would rely on a output as evidence of suitability for T particular.application.Output here based T • • an building code-accepted design c E - properties and analysis methods. i installation of Boise Cascade engineered e � o wood products must be in accordance with current installation Guide and applicable building codes.To obtain installation Guide or ask questions,please call a minimum=2" c=6-1/4" {800}232-0788 before installation. b minimum=3" d=24" BC CALCO,BC FRAMERO,AJS- e minimum=3" ALLJOISTO,BC RIM BOARDT",BCIV, Nailing schedule applies to both sides of the member. BOISE GLULAM SYSTEM,VERSA SIMPLE FRAMING -IAM®,VERSA-RIM Member has no side loads. PLUSS,VERSA-RIMQD, Connectors are:16d Sinker Nails VERSA-STRAND®,VERSASTUDO are trademarks of Boise Cascade Wood Products L.L.C. iii)Soise 0asrade Triple 1-314"x 8-114"VERSA-LAM(g)2.0 2800 DF Floor BeamlF1302 Dry 1 span No cantilevers 10/12 slope January 15,2017 19:15:53 BC CALC®Design Report Build 5684 File Name: New—Col-37—Wellington—Way Job Name: New Colonial Nome Description:Designs%FB02 Address: Lot 6,#37 Wellington Way Specifier: Floor Support Beam City,State,Zip:North Andover,MA01845 Designer: KK Customer: Company: KDK Design Code reports: ESR-1040 Misc: See Attic Floor Framing t3dt-W B1 BO Total Horizontal Product Length=13-11-00 Reaction Summary(Down/!Uplift)(lbs) Bearing Live Dead Snow Wind Roof Live BO,3-1/2" 2,923/0 1,061/0 B1,3-1/2" 2,923/0 1,061/0 Live Dead Snow Wind Roof Live Trib. Load Summary Tag Description Load Type Ref. Start End 100% 90% 115% 160% 126% 1 Attic Floor Load Unf.Area(1b/nA2) L 00-00-00 13-11-00 30 10 14-00-00 Controls Summary Value `y Allowable Duration Case Location Pos.Moment 12,961 ft-lbs 72.1% 100% 1 06-11-08 End Shear 3,375 lbs 36.6% 100% 1 01-00-12 Total Load Defl. L/265(0.61") 90.7% n/a 1 06-11-08 Live Load Defl. LJ361(0.448") 99.8% n/a 2 06-11-08 Max Defl. 0.61" 61% n/a 1 06-11-08 Span/Depth 17.5 n/a n/a 0 00-00-00 %Allow %Allow Bearing Supports Dim{Lx W) Value Support Member Material BO Post 3-1/2"x 3-1/2" 3,983 lbs n/a 43.4% Unspecified 61 Post 3-1/2"x 3-112" 3,983 lbs nla 43.4% Unspecified Cautions Member is not fully supported at post BO. A connector is required at this bearing. Member is not fully supported at post B1. A connector is required at this bearing. Notes Design meets Code minimum(U240)Total load deflection criteria. Design meets Code minimum(L1360)Live load deflection criteria. Design meets arbitrary(V)Maximum total load deflection criteria. Calculations assume member is fully braced. Design based on Dry Service Condition. Page 1 of 2 (ei�I Boise Cascade Triple 1-3/4"x 9-1/4"VERSA-LAM®2.0 2800 DF Floor Beam1F13O2 Dry 1 span No cantilevers 0/12 slope January 15,2017 19:15:53 BG CALC®Design Report Build 5684 File Name: New_CoI_37_Wellington_Way Job Name: New Colonial Home Description:Designs\FB02 Address: Lot 6,#37 Wellington Way Specifier: Floor Support Beam City,State,Zip:North Andover,MA 01845 Designer: KK Customer: Company: KDK Design Code reports: ESR-1040 Misc: See Attic Floor Framing Connection Diagram _ Disclosure b ..---d Completeness and accuracy of input must be verified by anyone who would rely on a i # output as evidence of suitability for • • particular application.Output here based o • o on building code-accepted design c properties and analysis methods. i—_• Installation of Boise Cascade engineered e o • o wood products must be in accordance with current Installation Guide and applicable building codes.To obtain Installation Guide or ask questions,please call a minimum=2" c=4-1/4" (800)232-0788 before installation. b minimum=3" d=24" BC CALC®,BC FRAMER,AJSTM e minimum=3" ALLJOISTO,BC RIM BOARDTm,BCI®, Nailing schedule applies to both sides of the member. BOISE M@,VE S -LAM@,SIMPLE FRAMING SYSTEM®;VERSA-IAMB,VERSA-RIM Member has no side loads. PLUS(&,VERSA-RIM@, Connectors are:16d Sinker Nails VERSA-STRANDV,VERSASTUD@are trademarks of Boise Cascade Wood Products L.L.C. aelse cascade Double 1-3/4"x 9-1/4"VERSA-LAM®2.0 2800 DF Floor Beam\FB03 Dry 11 span I No cantilevers 10/12 slope January 15,2017 19:23:54 BC CALC@ Design Report Build 5684 File Name: New—Col-37—Wellington—Way Job Name: New Colonial Home Description:Designs\FB03 Address: Lot 6,#37 Wellington Way Specifier: Floor Support Beam City,State,Zip:North Andover,MA 01845 Designer: KK Customer: Company: KDK Design Code reports: ESR-1040 Misc: See Attic Floor Framing B0 B1 Total Horizontal Product Length=12.02-00 Reaction Summary(Down/Uplift)(lbs) Bearing Live Dead Snow Wind Roof Live BO,3-1/2" 2,655/0 902/0 61,3-1/2" 2,565/0 90210 Live Dead Snow Wind Roof Live Trib. Load Summary Tag Description Load Type Ref. Start End 100% 90% 116% 160% 125% 1 Attic Floor Load Unf.Area(Ib/ftA2) L 00-00-00 12-02-00 30 10 14-00-00 Controls Summary Value %Allowable Duration Case Location Pas.Moment 9,739 ft-lbs 81.2% 100% 1 06-01-00 End Shear 2,853 lbs 46.4% 100% 1 01-00-12 Total Load Deft. 11270(0.52") 88.9% n/a 1 06-01-00 Live Load Defl. 0365(0.385") 98.6% n/a 2 06-01-00 Max Defl, 0.52" 52% n/a 1 06-01-00 Span/Depth 15.2 n/a n/a 0 00-00-00 %Allow %Allow Bearing Supports Dim (L x W) Value Support er MembMaterial SO Post 3-1/2"x 3-1/2" 3,457 lbs n/a 37.6% Unspecified B1 Post 3-1/2"x 3-1/2" 3,457 lbs n/a 37.6% Unspecified Notes Design meets Code minimum(L/240)Total load deflection criteria. Design meets Code minimum(Lt360)Live load deflection criteria. Design meets arbitrary(1")Maximum total load deflection criteria. Calculations assume member is fully braced. Design based on Dry Service Condition. Page 1 of 2 Sol-Cascade Double 1-3/4"x 9-1/4"VERSA-LAM®2.0 2800 DF Floor BeamXFB03 kw) IlEff= Dry 1 span No cantilevers 10112 slope January 15,2017 19:23:64 BC CALCQ Design Report Build 5684 File Name: New_Col_37 Wellington Way Job Name: New Colonial Home Description:Designs1FB03 Address: Lot 6,#37 Wellington Way Specifier: Floor Support Beam City,State,Zip:North Andover,MA 01845 Designer: KK Customer: Company: KDK Design Code reports: ESR-1040 Misc: See Attic Floor Framing Disclosure Connection Diagram Completeness and accuracy of input must s+-I b d be verified by anyone who would rely on a output as evidence of suitability for particular application.Output here based on building code-accepted design c properties and analysis methods. .� Installation of Boise Cascade engineered wood products must be in accordance with current installation Guide and applicable building codes.To obtain Installation Guide or ask questions,please call a minimum=2" c=5-1/4" (800)232-0788 before installation. b minimum=3" d=24" BC CALCO,BG FRAMERO,AJST1°, Member has n0 Side load& ALLJOISTO,BC RIM BOARD-,BCI4, BOISE GLULAM-,SIMPLE FRAMING Connectors are:16d Sinker Nails SYSTEM®,VERSA-LAMO,VERSA-RIM PLUS(5,VERSA-RIM0, VERSA-STRAND@,VERSA-STUN are trademarks of Boise Cascade Wood Products L.L.C. 1Q1S)Boisecascade Double 1-3/4"x 9-1/4"VERSA-LAMO 2.0 2800 DF Floor Beam\FB04 W Dry i 1 span(No cantilevers 10/12 slope January 15,2017 22:31:15 BC CALCO Design Report Build 5684 File Name: New_Col 37_Wellington Way Job Name: New Colonial Home Description:Designs\FB04 Address: Lot 6,#37 Wellington Way Specifier: Roof Support Beam City,State,Zip:North Andover,MA 01845 Designer: KK Customer: Company: KDK Design Code reports: ESR-1040 Misc: See Roof Framing i I 2 I i 1 o eo-w BO Bi Total Horizontal Product Length=10-00-00 Reaction Summary(Down/Uplift)(lbs) Bearing Live Dead Snow Wind Roof Live 60,3-112" 2,400/0 1,117/0 61,3-1/2" 2,400/0 1,11710 Live Dead Snow Wind Roof Live Trib. Load Summary Tag Description Load Type Ref. Start End 100% 90% 115% 160% 125%_ 1 Ceiling Load Unf.Area(Ib/ft^2) L 00-00-00 10-00-00 0 10 09-06-00 2 Roof Load Unf.Area(Ib/ftA2) L 00-00-00 10-00-00 40 10 12-00-00 Controls Summary Value %Allowable Duration Case Location Pas.Moment 8,004 ft-lbs 66.8% 100% 1 05-00-00 End Shear 2,769 lbs 45% 100% 1 01-00-12 Total Load Defl. U403(0.284") 59.6% n/a 1 05-00-00 Live Load Defl. U591(0.194") 61% n/a 2 05-00-00 Max Defl. 0.284" 28.4% n/a 1 05-00-00 Span/Depth 12.4 n/a n/a 0 00-00-00 %Allow %Allow Bearing Supports Dim (Lx W) Value Support MemberMaterial BO Post 3-1/2"x3-1/2" 3,517 lbs n/a 38.3% Unspecified B1 Post 3-1/2"x 3-1/2" 3,517 lbs n/a 38.3% Unspecified Notes Design meets Code minimum(L1240)Total load deflection criteria. Design meets Code minimum(L/360)Live load deflection criteria. Design meets arbitrary(1")Maximum total load deflection criteria. Calculations assume member is fully braced. Design based on Dry Service Condition. Page 1 of 2 H2�Boise Cascade Double 1-3/4"x 9-1/4"VERSA-LAM®2.0 2800 DF Floor BeamT1304 '.. V/ Dry 11 span No cantilevers 0/12 slope January 15,2017 22:31:15 BC CALCO Design Report No Build 5684 File Name: New—Col-37—Wellington—Way Job Name: New Colonial Home Description:DesignsNFB04 Address: Lot 6,#37 Wellington Way Specifier: Roof Support Beam City,State,Zip:North Andover,MA 01845 Designer: KK Customer: Company: KDK Design Code reports: ESR-1040 Misc: See Roof Framing Connection Diagram Disclosure r►I b N—d Completeness and accuracy of input must L� be verified by anyone whowould relyon a output as evidence of suitability for • �a a particular application.Output here basad on building code-accepted design c properties and analysis methods. Installation of Boise Cascade engineered •� • wood products must be in accordance with current Installation Guide and applicable building codes.To obtain Installation Guide or ask questions,please call a minimum=2" c=5-1/4" (800)232-0788 before installation. b minimum=3" d=24" BC CALCO.BC FRAMERO,AJS- Member has no side loads. ALLJOISTO,BC RIM BOARD-,SCIO, Connectors are:16d Sinker Nails BOISE GLULAMI-,SIMPLE FRAMING SYSTEMO,VERSA-LAM®,VERSA-RIM PLUS®,VERSA-RIM®, VERSA-STRAND@,VERSA-STUD(D are trademarks of Boise Cascade Wood Products L.L.C. /'V BolseCascade Triple 1-3/4"x 9-1/4"VERSA-LAMO 2A 2800 DF Floor Beam1FB05 '... V! Dry I 1 span I No cantilevers 10/12 slope January 15,2017 22:57:03 BC CALCO Design Report Build 5684 File Name: New_Col_37_Wellington_Way Job Name: New Colonial Home Description:Designs\PB05 Address: Lot 6,#37 Wellington Way Specifier: Floor Support Beam City,State,Zip:North Andover,MA 01845 Designer: KK Customer: Company: KDK Design Code reports: ESR-1040 Misc: See 2nd Floor Framing 1 1 1 1 llli ! 1 1 ! 1 1 NO BO B1 Total Horizontal Product Length=13-11-00 Reaction Summary(Down/Uplift)(lbs) Bearing Live Dead Snow Wind Roof Live 80,3-1/2" 2,923/0 1,061/0 B1,3-1/2" 2,923/0 1,061/0 Live Dead Snow Wind Roof Llve Trib. Load Summary Tag Description Load Type Ref. Start End 100% 90% 115% 1601 125% 1 2nd Floor Load Unf.Area(Ib/ft^2) L 00-00-00 13-11-00 30 10 14-00-00 Controls Summary Value %Allowable Duration Case Location Pas.Moment 12,961 ft-lbs 72.1% 100% 1 06-11-08 End Shear 3,375 Ids 36.6% 100% 1 01-00-12 Total Load Defl. L/265(0.61') 90.7% n/a 1 06-11-08 Live Load Def4. L/361(0.448") 99.8% n/a 2 06-11-08 Max Defl. 0.61" 61% n/a 1 06-11-08 Span/Depth 17.5 n/a n/a 0 00-00-00 %Allow %Allow Bearing Supports Dim.(L x W) Value Support Member Material 60 Post 3-1/2"x 3-1/2" 3,983 Ids n/a 43.4% Unspecified B1 Post 3-1/2"x 3-1/2" 3,983 Ids n/a 43.4% Unspecified Cautions Member is not fully supported at post BO. A connector is required at this bearing. Member is not fully supported at post B1.A connector is required at this bearing. Notes Design meets Code minimum(U240)Total load deflection criteria. Design meets Code minimum(L1360)Live load deflection criteria. Design meets arbitrary(1")Maximum total load deflection criteria. Calculations assume member is fully braced. Design based on Dry Service Condition. Page 1 of 2 (&Bolse'cascade Triple 1-314"x 9-1/4"VERSA-LAM®2.0 2800 DF Floor Beam1FB05 �VlJJ Dry 1 span No cantilevers 10/12 slope January 15,2017 22:57:03 BC CALCO Design Report Build 5684 File Name: New_Col_37_Wellington_Way Job Name: New Colonial Home Description:Designs\FB05 Address: Lot 6,#37 Wellington Way Specifier: Floor Support Beam City,State,Zip:North Andover,MA 01845 Designer: KK Customer: Company: KDK Design Code reports: ESR-1040 Misc: See 2nd Floor Framing Connection Diagram Disclosure �►{b It f-d Completeness and accuracy of input must L� be verified by anyone who would rely on a II output as evidence of suitability for o o particular application.Output here based on building code-accepted design Jproperties and analysis methods. _ Installation of Boise Cascade engineered a o c o wood products must be in accordance with current Installation Guide and applicable building codes.To obtain Installation Guide or ask questions,please call a minimum=2" c=4-114" (800)232-0788 before installation. b minimum=3" d=24" BC CALCO,BC PRAMERE),AJS-, e minimum=3° ALLJOISTO,BC RIM BOARD-,BCH Nailing schedule applies to both sides of the member. BOISE GLULAM-,SIMPLE FRAMING Member has no side loads. SYSTEM®,VERSA-LAMO,VERSA-RIM PLUS®,VERSA-RIM@, Connectors are:16d Sinker Nails VERSA-STRAND®,VERSA-STUD@ are trademarks of Boise Cascade Wood Products L.E.C. Boiseeascade quadruple 1-3/4"x 11-7/8"VERSA-LAM®2.0 2800 DF Floor Beam1FB06 VJ Dry i 1 span I No cantilevers 10112 slope January 15,2017 23:55:20 BC CALCQi}Design Report Build 5684 File Name: New_Col_37_Wellington Way Job Name: New Colonial Home Description:DesignsiFBO6 Address: Lot 6,#37 Wellington Way Specifier: Floor Support Beam City,State,Zip:North Andover,MA 01845 Designer: KK Customer: Company: KDK Design Code reports: ESR-1040 Misc: See 2nd Floor Framing � 1 14-00-06 BO B1 Total of Horizontal Design Spans=14-00-00 Reaction Summary(Down I Uplift)(lbs) Bearing Live Dead Snow Wind Roof Live BO 6,38710 2,33410 B1 6,35310 2,28810 Live Dead Snow Wind Roof Live Trib. Load Summary Tag Description Load Type Ref. Start End 100% 90% 115% 1601% 125% 1 2nd Floor Load Unf.Area(Ib/flA2) L 00-00-00 14-00-00 30 10 14-00-00 2 Attic Floor Load Unf.Area(lb/flA2) L 03-09-00 14-00-00 30 10 14-00-00 3 FB03 Point Load Cone.Pt.(lbs) L 03-09-00 03-09-00 2,555 928 n/a Controls Summary value %Allowable Duration Case Location Pas.Moment 32,710 ft-lbs 85.1% 100% 1 06-05-12 End Shear 8,103 lbs 51.3% 100% 1 01-00-12 Total Load Defl. L1284(0.592") 84.6% We 1 06-10-14 Live Load Defl. U386(0.435') 93.3% n/a 2 06-10.14 Max Defl. 0.592" 59.2% n/a 1 06-10-14 Span/Depth 14.1 n/a n/a 0 00-00-00 Notes Entered/Displayed Horizontal Span Length(s)=Clear Span+112 min.end bearing+ 1/2 intermediate bearing Design meets Code minimum(0240)Total load deflection criteria. Design meets Code minimum(L1360)Live load deflection criteria. Design meets arbitrary(1")Maximum total load deflection criteria. Minimum bearing length for BO is 1-11/16". Minimum bearing length for B1 is 1-5/8". Calculations assume member is fully braced. Design based on Dry Service Condition. Fastener Manufacturer.Simpson Strong-Tie,Inc. I Page 1 of 2 bili)Boise Cascade Quadruple 1-3/4"x 11-7/8"VERSA-LAM0 2A 2800 DF Floor Beam\FB06 Dry 11 span No cantilevers 10112 slope January 15,2017 23:55:20 BC CALC®Design Report Build 5684 File Name: New-COI-37-Wellington-Way Job Name: New Colonial Home Description:Designs\FB06 Address: Lot 6,#37 Wellington Way Specifier: Floor Support Beam City,State,Zip:North Andover,MA 01845 Designer: KK Customer: Company: KDK Design Code reports: ESR-1040 Misc: See 2nd Floor Framing Connection Diagram Disclosure ,.� b if .._d Completeness and accuracy of input must be verified by anyone who would rely on e output as evidence of suitability for particular application.Output here based on building code-accepted design . i_•� properties and analysis methods Installation of Boise Cascade engineered wood products must be in accordance with current installation Guide and applicable building codes.To obtain Installation Guide or ask questions,please call a minimum=1-1I2"c=8-718" (800)232-0788 before installation. b minimum=6" d=24" e minimum=1" BC CALCO,BC FRAMER�,AJSTM ALLJOISTO,BC RIM BOARD-,BCIQD, Connection design assumes point load is top-loaded. For connection design of side-loaded BOISE GLULAM",SIMPLE FRAMING point loads, lease consult a technical representative or professional of Record. SYSTEMV,VERSA-RI VERSALAhd�,VERSA-RIM P P P P PLUS�,VERSA-RIMS, Beams 7 inches wide will be assumed to be either top-loaded only,or equally loaded from VERSA-STRANDO,VERSA-STUDO are each side. trademarks of Boise Cascade Wood Install Screws with screw heads in the loaded ply. Products L.L.C. Member has no side loads. Connectors are:SDW22634 Boise cascade Double 1-3/4"x 9-1/4"VERSA-LAM®2.0 2800 DF Floor BeamkFB07 V/ Dry I 1 span I No cantilevers 0/12 slope January 16,2017 00:01:32 BC CALC@ Design Report Build 5684 File Name: New_Col_37_Wellington_Way Job Name: New Colonial Home Description:DesignsTB07 Address: Lot 6,#37 Wellington Way Specifier: Floor(Roof Support Beam City,State,Zip:North Andover,MAO 1845 Designer: KK Customer: Company: KDK Design Code reports: ESR-1040 Misc: See 2nd Floor Framing I I I 2 i I I 80 B1 Total Horizontal Product Length=07-06-00 Reaction Summary(Down I Uplift)(lbs) Bearing Live Dead Snow Wind Roof Live BO,3-1/2" 3,675/0 1,081/0 B1,3-1/2" 3,675/0 1,081/0 Live Dead Snow Wind Roof Live Trib. Load Summary Tag Description Load Type Ref. Start End 100% 90% 115% 160% 1251 1 2nd Floor Load Unf.Area(Ib/R^2) L 00-00-00 07-06-00 30 10 07-00-00 2 Attic Floor Load Unf.Area(Ib/ft^2) L 00-00-00 07-06-00 30 10 07-00-00 3 Roof load Unf.Area(Ib/ft^2) L 00-00-00 07-06-00 40 10 14-00-00 Controls Summary Value %Allowable Duration Case Location Pos.Moment 7,861 ft-lbs 65.6% 100% 1 03-09-00 End Shear 3,409 lbs 55A% 100% 1 01-00-12 Total Load Defl. 1-1556(0.152") 43.2% n/a 1 03-09-00 Live Load Defl. 0999(0.117") n/a n/a 2 03-09-00 Max Defl. 0.152" 15.2% n/a 1 03-09-00 Span I Depth 9.1 n/a n/a 0 00-00-00 %Allow %Allow Bearing Supports Dim.(L x W) Value Support Member Material BO Post 3-1/2"x 3-1/2" 4,756 lbs n/a 51.8% Unspecified B1 Post 3-1/2"x 3-1/2" 4,756 lbs n/a 51.8% Unspecified Notes Design meets Code minimum(1-1240)Total load deflection criteria. Design meets Code minimum(U360)Live load deflection criteria. Design meets arbitrary(1")Maximum total load deflection criteria. Calculations assume member is fully braced. Design based on Dry Service Condition. Page 1 of 2 t2lacise cascade Double 1-314"x 9-1/4"VERSA-LAM®2.0 2800 DF Floor BeamT1307 LTJ Dry 11 span No cantilevers 0112 slope January 16,2017 00:01:32 BC CALC0 Design Report Build 5684 File Name: New—Col-37—Wellington—Way Job Name: New Colonial Home Description:Designs1FB07 Address: Lot 6,#37 Wellington Way Specifier: Floor/Roof Support Beam City,State,Zip:North Andover,MA 01845 Designer: KK Customer: Company: KDK Design Code reports: ESR-1040 Misc: See 2nd Floor Framing Connection Diagram Disclosure �I b d Completeness and accuracy of input must L� be verified by anyone who would rely on a I output as evidence of suitability for —• • particular application.Output here based on building code-accepted design c r� properties and analysis methods. •� Installation of Boise Cascade engineered • wood products must be in accordance with current installation Guide and applicable building codes.To obtain Installation Guide or ask questions,please call a minimum=2" c=5-114" (800)232-0788 before installation. b minimum=3" d=24" BC CALCO,BC FRAMER@,AJS-, Member has no side loads. ALLJOIST®,BC RIM BOARW-,BCH Connectors are:16d Sinker Nails BOISE GLULAM-,SIMPLE FRAMING SYSTEM@,VERSA-LAM@,VERSA-RIM PLUSO,VERSA-RIM®, VERSA-STRAND,VERSA-STUD@are trademarks of Boise Cascade Wood Products L.L.C. �boiseCascade Triple 1-314"x 11-1/4"VERSA-LAM(g)2.0 2800 DF Floor Beam\FB08 V! Dry(1 span No cantilevers 10/12 slope January 16,2017 00:37:32 BC CALCO Design Report Build 5684 File Name: New_Col_37_Wellington_Way Job Name: New Colonial Home Description:Designs1FBO8 Address: Lot 6,#37 Wellington Way Specifier: Floor Support Beam City,State,Zip:North Andover,MA 01845 Designer: KK Customer: Company: KDK Design Code reports: ESR-1040 Mlsc: See 1st Floor Framing 1 BO B1 Total Horizontal Product Length=13-11-00 Reaction Summary(Down/Uplift)(lbs) Bearing Live Dead Snow Wind Roof Live BO,3-1/2" 3,897/0 1,080/0 B1,3-1/2" 3,89710 1,080/0 Live Dead Snow Wind Roof Live Trib. Load Summary Tag Description Load Type Ref. Start End 100% 90% 115% 160% 125% 1 1st Floor Load Unf.Area(Ib/ftA2) L 00-00-00 13-11-00 40 10 14-0000 Controls Summary Value %Allowable Duration Case Location Pos.Moment 16,192 ft-lbs 62.2°! 100% 1 06-11-08 End Shear 4,097 Itis 36.5% 100% 1 01-02-12 Total Load Dell. 1-/381(0.424") 63% n/a 1 06-11-08 Live Load Defl. L1487(0.332') 74% n/a 2 06-11-08 Max Defl. 0.424" 42.4% n/a 1 06-11-08 Span/Depth 14.4 n/a n/a 0 00-00-00 *1 Allow %Allow Bearing Supports Dim.(L x W) Value Support Member Material BO Post 3-1/2"x 3-1/2" 4,976 lbs n/a 54.2% Unspecified B1 Post 3-1/2"x 3-1/2" 4,976 lbs hla 54.2% Unspecified Cautions Member is not fully supported at post BO.A connector is required at this bearing. Member is not fully supported at post B1. A connector is required at this bearing. Notes Design meets Code minimum(LT240)Total load deflection criteria. Design meets Code minimum(1-1360)Live load deflection criteria. Design meets arbitrary(1")Maximum total load deflection criteria. Calculations assume member is fully braced. Design based on Dry Service Condition. Page 1 of 2 (VI' B.iseCascade Triple 1-3/4"x 11-1/4"VERSA-LAM(g)2.0 2800 DF Floor Beam1F608 '.. VV// 11111111= Dry 1 span No cantilevers 10112 slope January 16,2017 00:37:32 BC CALC(5 Design Report Build 5684 File Name: New Col-37—Wellington—Way Job Name: New Colonial Nome Description:Des1gns\FB08 Address: Lot 6,#37 Wellington Way Specifier: Floor Support Beam City,State,Zip:North Andover,MA 01845 Designer: KK Customer: Company: KDK Design Code reports: ESR-1040 Misc: See 1st Floor Framing Connection Diagram Disclosure b d— Completeness and accuracy of input must be verified by anyone who would rely on a • • o output as application. of suitability for particular application.Output here based on c • properties building code-acceptedmethods- Installation nd nalysia hods- hstallation of Boise Cascade engineered a • wood products must be in accordance with current Installation Guide and applicable building codes.To obtain Installation Guide a minimum=2" c=6-114"' or ask questions,please call (800)232-0788 before Installation. b minimum=3" d=24" e minimum=3" BC CALCO,BC FRAMERS,AJSTm ALLJOISTO,BC RIM BOARD-,BC18, Nailing schedule applies to both sides of the member. BOISE GLULAM-,SIMPLE FRAMING Member has no side loads. SYSTEM®,VERSA-LAMO,VERSA-RIM PLUS®,VERSA-RIM@, Connectors are:16d Sinker Nails VERSA-STRANDO,VERSA-STUD@are trademarks of Boise Cascade Wood Products L.L.C. ( yeotse Cascade Quadruple 2 x 10 SPF#2 Floor Beam1FB09 Dry 16 spans I No cantilevers 10/12 slope January 16,2017 00:47:31 BC CALCO Design Report Build 5684 File Name: New_Col_37_Wellington—Way Jab Name: New Colonial Home Description:Designs1FBO9 Address: Lot 6,#37 Wellington Way Specifier: Floor Support Beam City,State,Zip:North Andover,MA 01845 Designer: KK Customer: Company: KDK Design Code reports: NLGA Misc: See 1st Floor Framing ,9 0&-00-00 06-04-00 OS-09.00 07-09-00 08-0040 08-03-00 BO B1 B2 B3 84 B5 B6 Total of Horizontal Design Spans=42-01.00 Reaction Summary(Down/Uplift)(lbs) Bearing Live Dead Snow Wind Roof live SO 3,6781359 1,026/0 B1 8,05910 2,35710 B2 5,586/0 1,220/0 B3 4,755/0 1,013/0 B4 5,091/0 1,191/0 85 5,469/0 1,40010 B6 2,078/219 50710 Live Dead Snow Wind Roof Live Trib. Load Summary Tag Description Load Type Ref. Start End 100% 90% 116% 160% 125% 1 1st Floor Load Unf.Area(Ib/ft12) L 00-00-00 42-01-00 40 10 14-00-00 2 2nd Floor Load Unf.Area(Ib/ft12) L 00-00-00 12-04-00 30 10 14-00-00 3 Attic Floor Load Unf.Area(Ib/ft^2) L 00-00-00 04-00-00 30 10 14-00-00 Controls Summary Value %Allowable Duration Case Location Pos.Moment 5,650 ft-lbs 82.3% 100% 2 02-06-10 Neg.Moment -6.449 ft-lbs 94% 100% 4 06-00-00 End Shear 3,024 lbs 60.5% 100% 2 00-11-00 Cont.Shear 4,415 lbs 88.4% 100% 4 05-01-00 Total Load Defl. L/999(0.088") nla n/a 3 38-01-14 Live Load Dell. L/999(0.074") n/a n/a 11 38-01-14 Total Neg.Dell. L/999(-0.037') n/a n/a 3 30-01-07 Max Defl 0.088" nla n/a 3 38-01-14 Span/Depth 10.6 nla n/a 0 00-00-00 Notes 'age 1 of 2 Bohecascade Quadruple 2 x 10 SPF#2 Floor Beam1F13109 Dry 16 spans I No cantilevers 10/12 slope January 16,2017 00:47:31 BC CALC®Design Report Build 5684 File Name: New Col37_Wellington_Way Job Name: New Colonial Home Description:Designs\F_809 Address: Lot 6,#37 Wellington Way Specifier: Floor Support Beam City,State,Zip:North Andover,MA 01845 Designer: KK Customer: Company: KDK Design Code reports: NLGA Misc: See 1st Floor Framing Entered/Displayed Horizontal Span Length(s)=Clear Span+1/2 min.end bearing+ Disclosure 1/2 intermediate bearing Completeness and accuracy of input must Design meets Code minimum(U240)Total load deflection criteria. be verified by anyone who would rely on Design meets Code minimum(U360)Live load deflection criteria. output as evidence of suitability for Design meets arbitrary 1" Maximum total load deflection criteria. on building codular e-accepted Output here based 9 ry{ ) on building code-accepted design Minimum bearing length for SO is 1-7/8". properties and analysis methods. Minimum bearing length for B1 is 4-1/16". Installation of Boise Cascade engineered Minimum bearing length for B2 is 2-11116". wood products must be in accordance with current Installation Guide and applicable Minimum bearing length for B3 Is 2-1/4". building codes.To obtain Installation Guide Minimum bearing length for B4 is 2-7/16". or ask questions,please can Minimum bearing length for B5 is 2-11/16". (800)232-x768 before installation. Minimum bearing length for B6 is 1-1/2". BC CALCw,BC FRAMER0,AJS-, Calculations assume member is fully braced. ALUOISTO,BC RIM BOARD-,BCI®, Design based on Dry Service Condition. BOISE GLULAM-,SIMPLE FRAMING The analysis of solid sawn wood members is in accordance with the NQS and is limited to the SYSTEM®,VERSA-LAM®,VERSA-RIM output shown above. All other support and design for these products,including but not PLUSO,VERSA-RIM®, limited to notching,connections,installation,and en ineer/architect certification is the VE trademarks ANDS,VERSA-STUDS a e 9 trademarks of Boise Cascade Wood responsibility of the project's design professional of record. Products LLC. flTlablse Cascade Triple 1-3/4"x 9-1/4"VERSA-LAMO 2A 2800 DF Roof Beam1RB01 �t.J BC CALC®Design Report Dry 1 span No cantilevers 110/12 slope January 15,2017 22:28:57 Build 5684 File Name: New Col_37_Wellington_Way Job Name: New Colonial Home Description:Designs1RB01 Address: Lot 6,#37 Wellington Way Specifier: Roof Support Beam City,State,Zip:North Andover,MA 01845 Designer: KK Customer: Company: KDK Design Code reports: ESR-1040 Misc: See Roof Framing 21 1z so - B1 Total Horizontal Product Length=12-00-00 Reaction Summary(Down/Uplift)(tbs) Bearing Live Dead Snow Wind Roof rive BO,3-1/2 1,208/0 2,760/0 B1,3-1/2" 885/0 2,067/0 Live Dead Snow Wind Roof Live Trib. Load Summary Tag Description Load Type Ref. Start End100% 90°( 115% 360% 1251/ 1 Standard Load Unf.Area(Ib/ftA2) L 00-00-00 12-00-00 13 40 05-00-00 2 FB04 Point Loaad Cone.Pt.(lbs) L 04-04-00 04-04-00 1,117 2,400 n/a Controls Summary Value %Allowable Duration Case Location Pos.Moment 13,593 ft-lbs 65.7% 115% 4 04-04-00 End Shear 3,873 lbs 36.5% 115% 4 00-03-08 Total Load Defl. L/258(0.699") 69.7% n/a 4 05-09-00 Live Load Defl. U372(0.485") 64.5°% n/a 5 05-09-00 Max Dell. 0.699" 69.9°% n/a 4 05-09-00 Span/Depth 15 n1a n/a 0 00-00-00 Allow %Allow Bearing Supports Dim(L x W) Value Support Member Material BO Post 3-1/2"x 3-1/2" 3,968 lbs n/a 43.2% Unspecified B1 Post 3-1/2"x 3-1/2" 2,952 lbs n/a 321% Unspecified Slope and Cut Length Slope Fascia Depth Horiz Length Product Length Plumb Cut with Hanger to dbl.top plate 10/12 1-3/4" 12-00.00 16-03-02 Cautions Member is not fully supported at post BO. A connector is required at this bearing. Member is not fully supported at post B1. A connector is required at this bearing. Notes Design meets Code minimum(L/180)Total load deflection criteria. Design meets Code minimum(0240)Live load deflection criteria. Design meets arbitrary(1")Maximum total load deflection criteria. Calculations assume member is fully braced. Design based on Dry Service Condition. Fastener Manufacturer:Simpson Strong-Tie,Inc. Page 1 of 2 (Tl Boise Cascade Triple 1-3/4"x 9-1/4"VERSA-LAM®2.0 2800 DF Roof Beam1R13101 EgEg\\TY! Dry 1 span No cantilevers 10/12 slope January 15,2017 22:28:57 BC CALC(e}Design Report Build 5684 File Name: New_Col_37_Wellington Way Job Name: New Colonial Home Description:DesignstRB01 Address: Lot 6,#37 Wellington Way Specifier: Roof Support Beam City,State,Zip:North Andover,MA 01845 Designer: KK Customer: Company: KDK Design Code reports: ESR-1040 Misc: See Roof Framing Connection Diagram Disclosure b L— d—� Completeness and accuracy of input must L. be verified by anyone who would rely on a i output as evidence of suitability for • particular application.Output here based on building code-accepted design properties and analysis methods. • l• • Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes.To obtain installation Guide or ask questions,please call a minimum=1-1/2"c=6-1/4" (800)232-0788 before installation. b minimum=6" d=24" e minimum=1" BC CALCO,BC FRAMER®,AJS-, ALLJOISTO,BC RIM BOARD-,BCIV, Connection design assumes point load is top-loaded. For connection design of side-loaded BOISE GLULAMI-,SIMPLE FRAMING BvVERSA-LAW,VERSA-RIM Point loads,please consult a technical representative or professional of Record. PLUSQ),VERSA-RIMO, Install Screws with screw heads in the loaded ply. VERSASTRANDrd,VERSA-STUDS are Member has no side loads. trademarks of Boise Cascade Wood Connectors are:SDW22500 Products L1.C. �SJGN lZ 2�4G' Qt0 ¢ry ®®®® ®®®® ODOD 0000 DODD Fron/ifflevalion Pighl -levalfon LPO-721-2114 R,SEWED BY "'SPECTOR E—(� ����® "-- NCTT, These plans are intended for the a of a licensed contra for.If is INSPECTIONAL" SERVICES the resporslbdlfy of the conlracfot to verify corpliance with all local building '1g"��NORTH ANDOVER codes.Ilorreowrer/confracfor fo verify di�er�ion5,proaoyed rayon'and building r7alerials to be used prior to proceea'inq with cong}ruclior,. Snr;�: ;�r lZ c:,r�:lrlZ/Z.r.•f7 "a` Gh» >d b ex n y NowGolonir�qty, lio e 171Nel1irg1on flay North Andover,l7At 01845MET 978 A5 G'8i0,t9NrN�DKD S% NDIZ KOK DP56N,w"I 09,"IA, �5/GN Z�Z Hil Fi !Eii I 7H gi ! i .M Peor,fflevulion Leff Elevolion GENERAL NOTES: 1. ALL DIMENSIONS AND MATERIALS SPECIFIED ARE TO BE VERIFIED 5. FRAMING LUMBER SHALL BE NO. 2 GRADE SPRUCE-PINE-FIR OR BETTER. BY THE CONTRACTOR AND ANY ADJUSTMENTS MADE ACCORDINGLY. 6. ALL PENETRATIONS (PLUMBING, ELECTRICAL, HEATING, ETC.) THRU 2. ALL WORK SHALL BE COMPLETED IN COMPLIANCE WITH ALL FLOORS SHALL BE COMPLETELY FIRE CAULKED. APPLICABLE BUILDING, PLUMBLING & ELECTRICAL CODES. ANY OTHER LOCAL, STATE AND / OR FEDERAL CODES THAT MAY APPLY 7. ALL POST SHALL BE CONTINUOUS TO FOUNDATION. TO THIS PROJECT SHALL BE CONSIDERED AS PART OF THE CONSTRUCTION DOCUMENTS. 8. REFER TO BOISE SPECIFICATIONS AND CALCULATIONS FOR VERSA-LAM INSTALLATION. 3. ALL WASTE MATERIALS AND DEBRIS SHALL BE REMOVED AND DISPOSED OF PROPERLY. 4, ALL STRUCTURAL MATERIALS SHALL BE VOID OF ANY DEFECTS THAT DIMINISH THEIR CAPACITY TO FUNCTION IN AN ADEQUATE MANNER. STRUCTURAL ENGINEERING OR ANY OTHER PROFESSIONAL SERVICES THAT MAY BE REQUIRED SHALL BE PROVIDED BY OTHERS UNDER / 1 SEPERATE CONTRACT AND TERMS. AGN 6' ------------------------------------------ --------------- - 3823 6"5?ider --------------------------------- -------------- Z _____________ ___ _________________ 'i L.___________ -i 1 '832 1 ------ ------- ------ i i _ i ;GT.t€i. Fcz:ndation L--------- --------�= -----, i - , F (Zl#5 Pebai Al 7-op I ;Z)#5.�.'ebarlftPlid-5pan Z4 i 1 I ZG"u X/G"dc.Fi'q 14, i (Z)#5Pebar AtOJ/l� 42x%O boa P�kef 981,x Z8"X lam"Pp,�tdp Ft'g 4"TXk.:1 is Steel-ally,`yp• O 3'lt 4 - -- ----, 2 ----- i Z8' I �_---_----------_--�__- -_'-- - __ '----_ _-- _ _______=-=- 2="="c=?='=o 1 L___ _______ _ _ -- _ ____ _ __ _______J I i 7 k5 Wai to be 5f3 l-ypf X I q F-908,oei i i Z 6yp� 3oad,r age Side 5heanxall,See � i jri�e 1-314°x t!-1/4" i Garage Geifitq?o be 5/8 Fy/c X. FJetalt Ver�a-<-on 2.G 2800,9F - -� jyN�rn;3aard lR/I.�IaS?er HO i� 19,'x" 1 1 i2` I 1 ` r"1a>er-rent` 14' Garage i4' I i �Piaxrwnt.5tab I I I 4" 4>Ila 4"/lip,prop 5/ope for d"",4, l i t l�_JLJ Y i I I IPi�x;�rx'LNfr,d�5aeff %-r Z Ftre,�aAedt7oor `�� r---------------- ------------------J 1 ., I L.^ca;or, -,,X)oy Gori—!-r { I t"-fo 1 i I _____________________ J I _______________ ______ __-- _J, r— I 1 ________________________Z'-�/' L--- E r_—' _._________________I i i L ___________________________ J -----�—.._�13'_x'; l6' NOTES: roundcflon Plan 1, ALL DIMENSIONS AND MATERIALS SPECIFIED ARE TO BE VERIFIED BY THE CONTRACTOR AND ANY ADJUSTMENTS MADE ACCORDINGLY. onoTO-~7 l00/:4 f`1 I�JIOd=iaiJlb� Of 9 ---------------- INC 0�13 E7w7ma �w OWN I ,Z �69Z 9,�BZ ia�io � 9681 w04d�Q 961 � �l_l LO�d 0I9ILY+.L Ole AA? 0/91-LIPV on y,� /in y undo noon va 9bBZ ,Z! f7u,�i „L Pa=r�n 90Ed ;sed 606,j sod — �------ ------------- gz bZ:Zl (jr✓n� O ---------- —-- 9oz Z/ nail f 6ur�n9 Woo 1119 vtl-i k4:�if4;algal 0 Mc O M2„ !' „4-:9 NGi�vo O �,� 2832 2832 2846-2 � 0 0, N T ------- ---P.ca!--� G.^ate 2X6 waft GL. c I s, I 26 24° I S Poor �� Koil I 11 ----------------- i ------------------------ I DN ti vL. Oed#3 2g„ I �t/� --------------------J �QtZ55 Vl Fool EcJ.�?5 2842 2842 ——————-- 2842 2842 2842-Z i 3'9" 40, NOTES: 1, ALL DIMENSIONS AND MATERIALS SPECIFIED ARE TO BE VERIFIED Znd f"loor Lcyoul BY THE CONTRACTOR AND ANY ADJUSTMENTS MADE ACCORDINGLY, 2. WINDOW CALLOUTS ARE FOR ANDERSON 400 SERIES WINDOWS. W ry ry 3 CSN 4-dxlo P.T. l2"�Sor�l�be O'con Delow Utvly'igfool 4'Detow Grade p l4' W1Aruhor Dolt 7-nple:-3!4"x 9-1'14" 12`8° 4x6 PT.Post LVL Pleader, N 1121,0 Lag(1olis CWlac,T yp. Gha�r6t� f iu,^+bir Area l� (9 Gontr x for Toilef Abate Y Triple 1-314"x 9-1/4" %r a Lan 20 28.00 DF -- -- -- -- -- -- - - -- - -- -- -- -- -- -- -- -- -- -- -- -- Hush,oabte 5uppod - - - - - -- -- -- -- -- -- -- -- -- ��j 1 I L I vt I I Q I II \ v I /4 i I O i II o II 1 KZ I I t II II 24` — 28' WE I frlple 1-314"x 11-114" Versa-Lan 2.0 2800 OF 1 t4' �l I - - I -ILIA I J I � I __ __ __ _J __ __ __ __ __ 2` F009,Delo 2-2x10 �, !2"O 5orofube f 1 W1Digf.1 2x8 16"o.c.p.t. 151 F/oof rfol- lnq WlAnfhor Dolt 4x6 PT.Post ,_ ;, 2 2 �5Ic D0G F:u Gable 5up-vd Dean,F'u� 0u t 3f4``x 11-728" 0=1'cs'if4'x 9-124° Plunbirq Afea Vc.:>a-Lon 2.0 2800 DP e a'la 2.0 25500 DF Talcl Above 40; 6 ---- ----- ---------- I ii i --- ------��___ ----------moi I ii i � I 1 FDJS,Flush I II I II i riF e 1-324"x 9-114 Versa-Lan 2.0 2800,'?F I r -- 14` - 11 2-210 \f C K 1 1 k II `c I I � L - i _1 1 I -- � i i I i - 13'-`�' 2-�xlc? Dcub?e 1-324`x9-124" ergo Lan 2.0 2800 OF NOTES: 1—n [Moor F77faminq 1. ALL DIMENSIONS AND MATERIALS SPECIFIED ARE TO BE VERIFIED p BY THE CONTRACTOR AND ANY ADJUSTMENTS MADE ACCORDINGLY. �5/6N P�OZ.!"lug; i�iO3.Frvh i pc r`3f4"x?lr'4" rri e;3l4"x t14" Vers,-Lom Z.c 2-300 VcfSa'Lal1 Z.c 2-800,9P 4c' - - - - - - - - - - - - Q I I II I I I I I I I I I I I F - - L I I LF I II II It I I 14' i I II II I I f V I �.> _ - ---------------------I I I �- - - - - - -L illL- 1 J 4C) i fdpie F3fnr�"x�^l,tUV✓^^-If f" Vef9a":-aP Z.c GQc NOTES: Alt is Floor 1,rGf'71,nq O 1, ALL DIMENSIONS AND MATERIALS SPECIFIED ARE TO BE VERIFIED BY THE CONTRACTOR AND ANY ADJUSTMENTS MADE ACCORDINGLY. jGffLG,'3116"-1 �5/CSN O1c�rr•Gul Pae„Ffp. ' Q i I I t ( L -/,110,17-11t I i i 24' � Q! 7'fr //_3f9`x?-1/q„ 2.0 28001✓P ________----J L 1 10' L— —J - -_ - - —-- —T, 2x8 e?G"o.c. Perch pdler NOTES: lti 00f Frar rq 1. ALL DIMENSIONS AND MATERIALS SPECIFIED ARE TO BE VERIFIED BY THE CONTRACTOR AND ANY ADJUSTMENTS MADE ACCORDINGLY. SCA-/E'51/6"—P 2-Ig pidge K'idgeVent PooFGO&'STKuc7-/0N/, � board Zx10/gaffer--,e<`6"oc, jff5/C-)N A 1l2" cox P; Pod 1M?SO:V 77T53C) ST�Q;VG Tl� MU5T�E xTTI�G`!l=D 1-0 JOIST d 15" Q l Fell Pooftnq f ope= MU57-,9EWkkAFf'EDfk'00NOPAF7-ER 2x,@32"o.c.Gol(or7-,=es ft5vhall5higlen Ir-------------------- I i I e _ lox, L7WXVN IZx1O�iG°oc I rJi Ve."!�d 5o/4r`;1\ J � 5old D(ocxirrf Dehreen k'affer 51fop Od ail / K 381�of an �� A laches To 7 op Plafes wl,5do6"o,c. f'orq Length o%pfr ed Wall/'Of/ 5cdc-Yore r Typical For A'Poflers Frcr�d llbcve Ffoor Joist `J WALL GoIti1 STKIlG1/0141,' J � 24 Muds 6 l6"P.G. 1/2"GBX I lywood �xIQ s/6"oc. I ' Pudding f oner 5idirg,To.p-, —� P-91 In�la;ion � `)"5lrirgerGuf� I l i r I II ?2x6 pf. 22x,64e w/slll sealer i i i Na„ed S GILrd //;Z”o.d.Ax:bor PJoIIs L-------j Zxr'TJ.16"oc. 6' ac.,19"FrorlGoner-, ; 4_------ 2x6 c/61,0.c P-50 lnu(a?ion `-- --- Krze'Wcal Bor Proof,;ngj l\�\\i ------ I r /'WowGrode E 4' in. Well GorrpacLGra✓e! NOTES: 1. ALL DIMENSIONS AND MATERIALS SPECIFIED ARE TO BE VERIFIED BY THE CONTRACTOR AND ANY ADJUSTMENTS MADE ACCORDINGLY. G(055 �cCfI0l1 2. FOR ADDITIONAL FOUNDATION INFORMATION SEE FOUNDATION PLAN. 10 3. FOR ADDITIONAL FRAMING INFORMATION SEE FRAMING PLAN.! K'OOF C0NST.k'UCT10Nf \ 2xC,GPllor Ties g32"o.c. 1/2"C??X P/ywocd —————————— 7Z \\\ Fellfoof.,,nq/'aper f 5pha{{5hl q{e5 2-r2 Ktdge P%dge+len/ �v I �� Dogra \ 1 � \ 12 \ a10 I I I �/M/'SO/\1 MT530G ST�rJ1vG-Tlz I I 1 MUST PE ATTACHEP 7-0-10k57-ff 1�51' I I MUST Dc V'✓f'App D lIK'OUNa n AFT!? 111 /�a5fer 1 I i lK Vwlfcd C�(l�VIA L CONSrI?U'CTION- I i 2 2X6 5furls a 16"P.C. 1=6"0,c, 1/2"COX Plywood Ouddr'ng Paper 1 3 Zx8 Z 6 0/6"oc. I j i F"'ll 18 j i I I Y i Pore 1 0} -2x6 3/4"7-,1(5 f'ly ood I p I I Nobcd SGIcd i 2-Zxkd. I Folo I -9-90pl w/-ill Sea/er I I ZxIO ci6"o.c. j !/2"o,d,Itncnor!3Pl{5 � � I �6 o.c.,rZ P;orrCPr�rS I 1 r-------------------� II r-------------------� j 4x6 pd.1'0� I I I I i 1 II I I I 1 II I I I 4, i I below Grade i i i i �aruge t I It �r`---� Gorcge 5,ab aff�efs hofch J\� 4`Mir lh'el/Cortpccf Grime,' ,:[.., Z4' NOTES: 1, ALL DIMENSIONS AND MATERIALS SPECIFIED ARE TO BE VERIFIED BY THE CONTRACTOR AND ANY ADJUSTMENTS MADE ACCORDINGLY. (5afage Gro-,5-,5 —'-�)ec!1 l on 2. FOR ADDITIONAL FOUNDATION INFORMATION SEE FOUNDATION PLAN. SGjfL�, !l�u tl 3. FOR ADDITIONAL FRAMING INFORMATION SEE FRAMING PLAN. 5­p­M5r&�05(rap,Faxfa^.19"d ��' Tc r� of Ge,JlSIGN e:aI�afliior•of eaer Go tY.•c�r Cvoi„'z t-�/4"x.';-/4•'1 1f_,1-2d2J 1 1 5h_-afh.%n7 rs' t ! M5i/i30 5frap,This Side ! ! Geier a�(3oitcn cll7eader f t \ t Jak9 Z-Z✓ \ \ 4S'ood 5trturrd PaJ 12x{Jocks aad 1-2a6 K,'.7 5f�;-�l \t \\ Musf OGontt—P:ors 8-i /2"o ridd_V tiq 11 7-opdIN,#77. OfVlV1 t / / 1 5ira�.^ca 5T11.014 5frap P.e ! 1 r'4"Min -bed.In Gcccre?e 1 1 t 5 I I 1 1 / t .nor f3olr's Garxiirucas Gor�rr,,`e I'ourzfalion 7"Mir,Er,krd,Tjp. ( I tfjl l 5?en Wa%Reirfwced.r/ Del al #4 Rcb�Top ff OtVi—,,Typ I 5r`t1D Gc.xr tn��dldicu, 5hearwall,`lcalc,/None #4 rebar I I #4 rebar/ Paxcn 5lv_a/h to tlea,Wi/n3"o.c.&ia'Cf If J 8d:'Fails ad i"ac:ir,,NlStuds Ar Ptd— f r 1 lEnd 1 \ @istance j 1 \ from comer) GENERAL NOTES: j / 1 ! 1 1. ALL DIMENSIONS AND MATERIALS SPECIFIED ARE TO BE VERIFIED I ( a 8Y THE CONTRACTOR AND ANY ADJUSTMENTS MADE ACCORDINGLY. \ \ Wood 5t2 4cd Pm'MuslPcG..ntnratSPror, 2. ALL WORK SHALL BE COMPLETED IN COMPLIANCE WITH ALL -opcfwoTT £'/�'f­dvv.1/ APPLICABLE BUILDING, PLUMBLING & ELECTRICAL CODES. ANY OTHER LOCAL, STATE AND / OR FEDERAL CODES THAT MAY APPLY TO.THIS PROJECT SHALL BE CONSIDERED AS PART OF THE CONSTRUCTION DOCUMENTS. 3. ALL WASTE MATERIALS AND DEBRIS SHALL BE REMOVED AND - DISPOSED OF PROPERLY. 4. ALL STRUCTURAL MATERIALS SHALL BE VOID OF ANY DEFECTS THAT DIMINISH THEIR CAPACITY TO FUNCTION IN AN ADEQUATE MANNER. STRUCTURAL ENGINEERING OR ANY OTHER PROFESSIONAL SERVICES THAT MAY BE REQUIRED SHALL BE PROVIDED BY OTHERS UNDER SEPERATE CONTRACT AND TERMS, 5. FRAMING LUMBER SHALL BE N0. 2 GRADE SPRUCE—PINE—FIR OR BETTER. 6. ALL PENETRATIONS (PLUMBING, ELECTRICAL, HEATING, ETC.) THRU FLOORS SHALL BE COMPLETELY FIRE CAULKER t 7. ALL POST SHALL BE CONTINUOUS TO FOUNDATION, 5heglwai1 8. REFER TO BOISE SPECIFICATIONS AND CALCULATIONS FOR VERSA—LAM INSTALLATION. 5�i�:3ti�"-;,,Qn 2