HomeMy WebLinkAboutMiscellaneous - 37 SULLIVAN STREET 9/22/2017 • 1 1 i r i North Andover Health Department Community and Economic Development Division ONSITE WASTEWATER SYSTEM CONSTRUCTION NOTES LOCATION INFORMATION ADDRESS: 37 Sullivan Street MAP: 107,8 LOT: 0100 INSTALLER: Todd Bateson — Bateson Enterprises DESIGNER: PLAN DATE: BOH APPROVAL DATE ON PLAN: D-Box Repair INSPECTIONS TANK INSPECTION; DATE OF BED BOTTOM INSPECTION: DATE OF FINAL CONSTRUCTION INSPECTION: 9/22/2017 DATE OF FINAL GRADE INSPECTION: SITE CONDITIONS ❑ Contractor reports any changes to design plan ❑ Existing septic tank properly abandoned ❑ Internal plumbing all to one building sewer t ® Topography not appreciably altered Comments: SEPTIC TANK ® Building sewer in continuous grade, on compacted firm base ❑ Cleanouts per plan ❑ Bottom of tank hole has 6" stone base Weep hole plugged ❑ 1500 gallon tank has been installed t H-10 loading t ❑ Monolithic tank construction ❑ Water tightness of tank has been achieved by visual testing ❑ Inlet tee installed, centered under access port ❑ Outlet tee installed, centered under access port (gas baffle/effluent filter) ❑ inch cover to within 6" of finish grade installed over one access port ❑ Hydraulic cement around inlet & outlet Comments: PUMP CLAMBER ❑ Bottom of tank hole has 6° stone base ❑ Weep hole plugged ❑ 1500 gallon Pump Chamber installed ❑ H-10 loading ❑ Monolithic tank construction ❑ Inlet tee installed, centered under access port ❑ Pump(s) installed on stable base ❑ Alarm float working ❑ Pump On/Off floats working ❑ Separate on/off floats ❑ Drain hole in pressure line ❑ cover at final grade installed over pump access pork ❑ Watertightness of tank has been achieved by testing ❑ Hydraulic cement around inlet & outlet Comments: CONTROL PANEL ❑ Alarm & Pump are on separate circuits ❑ Alarm sounds when float is tripped ❑ Location of control panel: basement ❑ Alarm signal located inside: basement Comments: DISTRIBUTION-BOX Installed on stable stone base ❑ H-20 D-Box ❑ Inlet tee (if pumped or >0.08'/foot) �I Hydraulic cement around inlet & outlets ❑ Observed even distribution ❑ Speed levelers provided (not required) Schedule 40 PVC Pipe Comments: 9/22/2017 All Set. Brian LaGrasse SOIL ABSORPTION SYSTEM (General) ❑ Bottom of SAS excavated down to C soil layer, as provided on plan ❑ Size of SAS excavated as per plan ❑ Title 5 sand installed, if specified on plan ❑ 40 Mil HDPE barrier installed ❑ Laterals installed and ends connected to header (and vented if impervious material above) ❑ Elevations of laterals and chambers installed as on approved plan ❑ Retaining wall (boulder/ concrete /timber/ block) ❑ Final cover as per plan Comments: SOIL ABSORPTION SYSTEM (Gravel-less Chambers) ❑ Brand and Model of Chamber: Standard Quick 4 Infiltrator Chambers ❑ Number of chambers per row: Number of rows (trenches): Comments.- Total Chambers FINAL GRADE ❑ Loamed ❑ Seeded ❑ Cover per plan Comments: DOCUMENTS NEEDED ❑ Certification of Installation Form submitted By engineer and signed and dated by Engineer and installer As-Built Plan BM HR = HI SYSTEM ELEVATIONS ROD AS-BLT INVERT DESIGN INVERT ELEVATION ELEV ELEV Benchmark Building Sewer OUT Septic Tank IN Septic Tank OUT Pump Chamber IN Pump Chamber OUT Distribution Box IN Distribution Box OUT Lateral 1 TOP ------------ Lateral 1 INVERT Lateral 2 TOP Lateral 2 INVERT ----------------------------------------------------------------------------------------------------------- Lateral 3 TOP -------------- Lateral 3 INVERT Lateral 4 TOP Lateral 4 INVERT Lateral 5 TOP Lateral 5 INVERT Lateral 6 TOP Lateral 6 INVERT -------------------_ __Top of Chamber ------------- Bottom of Bed/Chamber ---------–----- -----------------—–------------- SKETCH PLAN CRITICAL SETBACK DISTANCES Mark those distances checked in the field against the design plan and regulatory setback Tank SAS Sewer ® Property line 10 10 -- ® Cellar wall 10 20 -- ® Inground pool 10 20 -- ® Slab foundation 10 10 -- Deck, on footings, etc 5 10 -- ® Waterline 10 10 101 ® Private drinking well 75 100 50 ® Irrigation well 75 100 r Z Surface Water 25 50 ® Bordering Vegetated Wetland , Salt Marsh, Inland/Coastal Banka 75 .100 ® Wetlands bordering surface water supply or trib, (in Watershed) 150 150 El Trib. to surface water supply 325 325 ® Public well 400 400 ® Interim Wellhead Prot. Area Reservoirs 400 400 ® Drains (wat. supply/trib.) 50 100 ® Drains (intercept g.w.) 25 50 ® Drains (Other)Foundation 10(5) 20(1.0) ® Drywells 20 25 i Suction line 222(2) 2 1.00 feet is a minimum acceptable distance and no variance is allowed for a lesser distance(NA 5.02). 1 3 As defined in 310 CMR 1.0.55, 1.0.32, 10.54, and 10.30,respectively,pursuant to 15.211(3), also by NA r wetland bylaws