Loading...
HomeMy WebLinkAboutMiscellaneous - 45 WELLINGTON WAY 10/18/2017 (2) Forth Andover Health Department Community and Economic Development Division ONSITE WASTEWATER SYSTEM CONSTRUCTION NOTES LOCATION INFORMATION ADDRESS: 45 Wellington Way Lot 5 MAP: 105,C LOT: 88 INSTALLER: Dave Maynard DESIGNER: Christiansen and Sergi PLAN DATE: February 22, 2016 BOH APPROVAL DATE ON PLAN: April 6, 2017 INSPECTIONS TANK INSPECTION: 9/12/2017 DATE OF BED BOTTOM INSPECTION:9/12/2017 DATE OF FINAL CONSTRUCTION INSPECTION: 9/22/2017 DATE OF FINAL GRADE INSPECTION:10/11/2017 SITE CONDITIONS ® Contractor reports any changes to design plan N/A Existing septic tank properly abandoned ® Internal plumbing all to one building sewer ® Topography not appreciably altered Comments: Mill River SEPTIC TANK ® Building sewer in continuous grade, on compacted firm base j N/A Cleanouts per plan ® Bottom of tank hole has 6" stone base ® Weep hole plugged ® 1500 gallon tank has been installed H-10 loading ® Monolithic tank construction ® Watertightness of tank has been achieved by visual testing ® Inlet tee installed, centered under access port M Outlet tee installed, centered under access port (gas baffle/effluent filter) ® 24" inch cover to finish grade infinish grade installed over access port ® Neoprene boots around & outlet Comments: 9/12/2017 B. LaGrasse 9/22/2017 Mill River DISTRIBUTION-BOX ® Installed on stable stone base ® H-20 D-Box ❑ Inlet tee (if pumped or >0.08'/foot) ® Hydraulic cement around inlet & outlets Z Observed even distribution ® Speed levelers provided (not required) ® Schedule 40 PVC Pipe Comments: M. Grant SOIL ABSORPTION SYSTEM (General) ® Bottom of SAS excavated down to C soil layer, as provided on plan ® Size of SAS excavated as per plan ® Title 5 sand installed, if specified on plan ® 40 Mil HDPE barrier installed ® Laterals installed and ends connected to header (and vented if impervious material above) ® Elevations of laterals and chambers installed as on approved plan NIA Retaining wall (boulder/ concrete 1 timber/ block) ❑ Final cover as per plan Comments: 9112/17 39' x 36' B. LaGrasse FINAL GRADE ® Loamed ® Seeded ® Cover per plan Comments: M. Grant DOCUMENTS NEEDED ® Certification of Installation Form submitted By engineer and signed and dated by Engineer and installer ® As-Built Plan BM HR = HI = SYSTEM ELEVATIONS ROD AS-BLT INVERT DESIGN INVERT ELEVATION ELEV ELEV Benchmark Building Sewer OUT Septic Tank IN Septic Tank OUT Pump Chamber IN Pump Chamber OUT Distribution Box IN Distribution Box OUT Lateral 1 TOP Lateral 1 INVERT Lateral 2 TOP Lateral 2 INVERT Lateral 3 TOP Lateral 3 INVERT Lateral 4 TOP Lateral 4 INVERT Lateral 5 TOP Lateral 5 INVERT x Lateral 6 TOP Lateral 6 INVERT Top of Chamber Bottom of Bed/Chamber CRITICAL SETBACK DISTANCES Mark those distances checked in the field against the design plan and regulatory setback Tank SAS Sewer ® Property line 10 10 -- ® Cellar wall 10 20 -- ® Inground pool 10 20 -- ® Slab foundation 10 10 -- ® Deck, on footings, etc 5 10 -- ® Waterline 10 10 10' ® Private drinking well 75 100, 50 Irrigation well 75 100 ® Surface Water 25 50 ® Bordering Vegetated Wetland , Salt Marsh, Inland/Coastal Banka 75 100 ® Wetlands bordering surface water supply or trib. (in Watershed) 150 .150 ® Trib. to surface water supply 325 325 Public well 400 400 ® Interim Wellhead Prot. Area ® Reservoirs 400 400 ® Drains (wat. supply/trib.) 50 100 ® Drains (intercept g.w.) 25 50 ® Drains (Other)Foundation 10 (5) 20 (10) ® Drywells 20 25 ° Suction line 222(2) z 100 feet is a minimum acceptable distance and no variance is allowed for a lesser distance(NA 5.02). s As defined in 310 CMR 10.55, 10.32, 10.54,and 10.30,respectively,pursuant to 15.211(3),also by NA wetland bylaws