HomeMy WebLinkAboutMiscellaneous - 11 PURITAN AVENUE 10/26/2017 North Andover Wealth Department
Community and Economic Development Division
ONSITE WASTEWATER SYSTEM CONSTRUCTION NOTES
LOCATION INFORMATION
ADDRESS: 11 Puritan Ave MAP: 107 LOT: 0132
INSTALLER: James Kellett
DESIGNER: Hayes Engineering — Gordie Rogerson
PLAN DATE: August 3, 2017
BOH APPROVAL DATE ON PLAN: August 24, 2017
INSPECTIONS
TANK INSPECTION:
DATE OF BED BOTTOM INSPECTION:
DATE OF FINAL CONSTRUCTION INSPECTION: 9/29/2017
DATE OF FINAL GRADE INSPECTION:10/12/2017
SITE CONDITIONS
® Contractor reports any changes to design plan
N/A Existing septic tank properly abandoned
N/A Internal plumbing all to one building sewer
® Topography not appreciably altered
Comments: Existing leach trenches to remain in use
SEPTIC TANK
❑ Building sewer in continuous grade, on
compacted firm base
❑ Cleanouts per plan
❑ Bottom of tank hole has 6" stone base
❑ Weep hole plugged
❑ 1500 gallon tank has been installed
H-10 loading
❑ Monolithic tank construction t
❑ Water tightness of tank has been achieved by
visual testing
❑ Inlet tee installed, centered under access port
❑ Outlet tee installed, centered under access port
(gas baffle/effluent filter)
❑ inch cover to within 6" of finish grade
installed over one access port
❑ Hydraulic cement around inlet & outlet
Comments: Existing Septic tank to remain in use
PUMP CHAMBER
❑ Bottom of tank hole has 6" stone base
❑ Weep hole plugged
❑ 1500 gallon Pump Chamber installed
❑ H-10 loading
❑ Monolithic tank construction
❑ Inlet tee installed, centered under access port
❑ Pump(s) installed on stable base
❑ Alarm float working
❑ Pump On/Off floats working
❑ Separate on/off floats
❑ Drain hole in pressure line
❑ cover at final grade installed over pump
access port
❑ Watertightness of tank has been achieved by
testing
❑ Hydraulic cement around inlet & outlet
Comments:
CONTROL PANEL
❑ Alarm & Pump are on separate circuits
❑ Alarm sounds when float is tripped
❑ Location of control panel: basement
❑ Alarm signal located inside: basement
Comments:
DISTRIBUTION-BOX
Installed on stable stone base
❑ H-20 D-Box
N/A Inlet tee (if pumped or >0.08'/foot)
Hydraulic cement around inlet & outlets
Observed even distribution
Speed levelers provided (not required)
Z Schedule 40 PVC Pipe
Comments: New D-Box Installed
SOIL ABSORPTION SYSTEM (General)
Bottom of SAS excavated down to C soil layer,
as provided on plan
Size of SAS excavated as per plan
Title 5 sand installed, if specified on plan
N/A 40 Mil HDPE barrier installed
Laterals installed and ends connected to
header (and vented if impervious material
above)
Elevations of laterals and chambers installed as on
approved plan
N/A Retaining wall (boulder/ concrete /timber/ block)
F-1 Final cover as per plan
Comments: Sludge in the existing (2) leach trenches have been removed and
remain in use. (2) new additional leach trenches have been installed in the
original reserve area and are also in use. There are currently (4) leach trenches
being used for the existing dwelling
The new leach trenches were set at the same elevation as the existing leach
trenches which are about 0.09-0.15" low compared to the design plan elevation.
SOIL ABSORPTION SYSTEM (Gravel-less Chambers)
M Brand and Model of Chamber: Standard Quick
4 Infiltrator Chambers
F-1 Number of chambers per row:
F-1 Number of rows (trenches):
Comments-, Total Chambers
FINAL GRADE
Loamed
Seeded
Z Cover per plan
Comments:
DOCUMENTS NEEDED
Certification of Installation Form submitted
By engineer and signed and dated by
Engineer and installer
As-Built Plan
BM =
HR =
HI
SYSTEM ELEVATIONS
_-------- —.__.. _.._..
ROD
-------------
ROD AS-BLT INVERT DESIGN INVERT
ELEVATION ELEV ELEV
Benchmark
ITmIT —----------
Buildinq Sewer OUT
—--- ----------
Septic Tank IN
Septic Tank OUT
Pump Chamber IN,—------- --------------
Pump Chamber OUT
------------
Distribution Box IN
Distribution Box OUT
Lateral 1 TOP
Lateral 1 INVERT
Lateral 2 TOP
Lateral 2 INVERT
Lateral 3 TOP
Lateral 3 INVERT
Lateral 4 TOP
Lateral 4 INVERT
Lateral 5 TOP
Lateral 5 INVERT
Lateral 6 TOP
Lateral 6 INVERT
----------------
............... —---------
Top of Chamber
Bottom of Bed/Chamber
SKETCH PLAN
BM = 170.04
HR = 5.37
HI = 175.41
SYSTEM ELEVATIONS
ROD AS-BLT INVERT DESIGN INVERT
ELEVATION ELEV ELEV
Benchmark
Building Sewer OUT
Septic Tank IN ----
Septic Tank OUT 6.22 168.64 ----
Distribution Box IN 6.50 168.56 168.58
Distribution Box OUT 6.66 168.40 168.41
Lateral 1 TOP 6.83 / 7.10 168.23 / 167.96 168.32 168.08
Lateral I INVERT
Lateral 2 TOP 6.83 / 7.13 168.23 / 167.93 168.321 168.08
Lateral 2 INVERT
Lateral 3 TOP 6.83 / 7.13 168.23 / 167.93 168.32 168.08
Lateral 3 INVERT
Lateral 4 TOP 6.83 / 7.13 168.231 167.93 168.321 168.08
Bottom of Trench]_____ 9.25 166.2 166.3
CRITICAL SETBACK DISTANCES
Mark those distances checked in the field against the design plan and regulatory
setback
Tank SAS Sewer
Property line 10 10
Cellar wall 10 20
Inground pool 10 20
Slab foundation 10 10
Deck, on footings, etc 5 10 --
Waterline 10 10 101
Private drinking well 75 1002 50
Irrigation well 75 100
Surface Water 25 50
Bordering Vegetated Welland
Salt Marsh,inland/Coastal Bank3 75 100
Wetlands bordering surface
water supply or trib. (in Watershed) 150 150
Trib. to surface water supply 325 325
Z Public well 400 400
Interim Wellhead Prot, Area
Reservoirs 400 400
Z Drains (wat. supply/trib.) 50 100
Drains (intercept g.w.) 25 50
Drains (Otber) Foundation 10(5) 20(10)
Drywells 20 25
1 Suction line 222(2)
2 100 feet is a minirrilarn acceptable distance and no variance is allowed for a lesser distance(NA 5.02).
3 As defined in 310 CMR 10.55, 1032, 10.54,and 10,30,respectively,pursuant to 15.211(3),also by NA
wetland bylaws