HomeMy WebLinkAboutDenial - 25 WELLINGTON WAY 8/11/2017 FILE
C,r
North Andover Health Department
fommunity and Economic Development Division
August 11, 2017
Philip Christiansen, P.E.
Christiansen and Sergi, Inc.
160 Summer Street
Haverhill, MA 01830
Re: 25 Wellington Way (Map 1050, Lot 90, Subdivision Lot 7)
Dear Mr. Christiansen,
The proposed wastewater system design plan for the above site dated July 25, 2016, with a final
revision date of July 25, 2017 and received on July 25, 2017 has been reviewed. T..Jnfortunately,
the plan cannot be approved until the following items are corrected. The specific section in Title
5; 310 CMR 15.000, or North Andover regulation that is not met by this design follows each
item where applicable.
1. The foundation drain location and the elevation are not shown on the design plan(NA
3.2).
i
2. On sheet 1. of 2,the site plan view does not depict the same finish grading in the location 1
of the septic tank,as shown on the profile view. J
i
3. On sheet 1 of 2, tl.e test pits are not labeled.
Please feel free to contact the office or Mill River Consulting at 978-282-0014 with any
questions you may have. We look forward to working with you to obtain a wastewater treatment
and dispersal system which will be in compliance with all regulations and assure protection of
public health and the environment of North Andover.
Page 1. of 2
North Andover Health Department, Town Hall, 120 Main Street,
North Andover,MA 01845 Phone: 978.688.9540 :Fax: 978.688. 9542
Sincer
y
Tian
ian J. LIKIGIrasse, CEITT
Director of Public Health
cc: Messina Development Company
File
..........................-'--.............. ..................
Page 2 o172
North Andover Health Department, Town Hall, 120 Main Street,
North Andover, MA 01845 Phone: 978.688.9540 Fax: 9'78.688. 9542