HomeMy WebLinkAboutMiscellaneous - 127 VEST WAY 11/22/2017 (2)
North Andover Health Department
Community and Economic Development Division
ONSITE WASTEWATER SYSTEM CONSTRUCTION NOTES
LOCATION INFORMATION
ADDRESS: 127 Vest Way MAP: 104.B LOT: 0033
INSTALLER: John Shaw Wildwood Excavation Inc. jtshaw3@gmail.com
DESIGNER: Joseph Serwatka
PLAN DATE: 11/17/2016 final revision 7/26/2017 received on July 28, 2017
BOH APPROVAL DATE ON PLAN: 8/10/2017
INSPECTIONS
TANK INSPECTION: 10/6/2017
DATE OF BED BOTTOM INSPECTION: 10/5/2017
DATE OF FINAL CONSTRUCTION INSPECTION: 10/18/2017
DATE OF FINAL GRADE INSPECTION: 10/23/2017
SITE CONDITIONS
Contractor reports any changes to design plan
Existing septic tank properly abandoned
Internal plumbing all to one building sewer
Topography not appreciably altered
Comments:
SEPTIC TANK
Building sewer in continuous grade, on
compacted firm base
Cleanouts per plan
Bottom of tank hole has 6” stone base
Weep hole plugged
1500 gallon tank has been installed
H-10 loading
Monolithic tank construction
Water tightness of tank has been achieved by
visual testing
Inlet tee installed, centered under access port
Outlet tee installed, centered under access port
(gas baffle/effluent filter)
24” inch cover to within 6” of finish grade
installed over one access port
Neoprene boots around inlet & outlet
Comments:
PUMP CHAMBER
Bottom of tank hole has 6" stone base
Weep hole plugged
1500 gallon Pump Chamber installed
H-10 loading
Monolithic tank construction
Inlet tee installed, centered under access port
Pump(s) installed on stable base
Alarm float working
Pump On/Off floats working
Separate on/off floats
Drain hole in pressure line
_____ cover at final grade installed over pump
access port
Water tightness of tank has been achieved by
_______ testing
Hydraulic cement around inlet & outlet
Comments:
CONTROL PANEL
Alarm & Pump are on separate circuits
Alarm sounds when float is tripped
Location of control panel: basement
Alarm signal located inside: basement
Comments:
DISTRIBUTION-BOX
Installed on stable stone base
H-20 D-Box
Inlet tee (if pumped or >0.08’/foot)
Hydraulic cement around inlet & outlets
Observed even distribution
Speed levelers provided (not required)
Schedule 40 PVC Pipe
Comments:
SOIL ABSORPTION SYSTEM (General)
Bottom of SAS excavated down to C soil layer,
as provided on plan
Size of SAS excavated as per plan
Title 5 sand installed, if specified on plan
40 Mil HDPE barrier installed
Laterals installed and ends connected to
header (and vented if impervious material
above)
Elevations of laterals and chambers installed as on
approved plan
N/ARetaining wall (boulder / concrete / timber/ block)
Final cover as per plan
Comments: Added vent to the leach field. Sand in trench - good per B. LaGrasse
45 x 30
SOIL ABSORPTION SYSTEM (Gravel-less Chambers)
Brand and Model of Chamber: Standard Quick
4 Infiltrator Chambers
Number of chambers per row: 7
Number of rows (trenches): 6
Comments: Total Chambers = _42_
FINAL GRADE
Loamed
Seeded
Cover per plan
Comments: looks great per Michele Grant
DOCUMENTS NEEDED
Certification of Installation Form submitted
By engineer and signed and dated by
Engineer and installer
As-Built Plan
Setup#1 Setup#2
BM = 100.00 BM = 93.00
HR = 0.74 HR = 1.86
HI = 100.74 HI = 94.86
SYSTEM ELEVATIONS
ROD AS-BLT INVERT DESIGN INVERT
ELEVATION ELEV ELEV
Benchmark Setup #1
Building Sewer OUT 3.72 96.67 96.45
Septic Tank IN 4.08 96.31 96.25
Septic Tank OUT 4.41 95.98 96.00
Pump Chamber IN
Pump Chamber OUT
Setup #2
Distribution Box IN 3.43 91.08 91.00
Distribution Box OUT 3.65 90.86 90.83
Lateral 1 TOP 3.78
Lateral 1 INVERT 90.73 90.78
Lateral 2 TOP 3.78
Lateral 2 INVERT 90.73 90.78
Lateral 3 TOP 3.78
Lateral 3 INVERT 90.73 90.78
Lateral 4 TOP 3.78
Lateral 4 INVERT 90.73 90.78
Lateral 5 TOP 3.78
Lateral 5 INVERT 90.73 90.78
Lateral 6 TOP 3.78
Lateral 6 INVERT 90.73 90.78
Lateral 7 TOP 3.78
Lateral 7 INVERT 90.73 90.78
Top of Chamber 91.2 91.2
Bottom of Bed/Chamber 90.5 90.5
SKETCH PLAN
CRITICAL SETBACK DISTANCES
Mark those distances checked in the field against the design plan and regulatory
setback
Tank SAS Sewer
Property line 10 10 --
Cellar wall 10 20 --
Inground pool 10 20 --
Slab foundation 10 10 --
Deck, on footings, etc 5 10 --
1
Waterline 10 10 10
2
Private drinking well 75 100 50
Irrigation well 75 100
Surface Water 25 50
Bordering Vegetated Wetland ,
3
Salt Marsh, Inland / Coastal Bank 75 100
Wetlands bordering surface
water supply or trib. (in Watershed) 150 150
Trib. to surface water supply 325 325
Public well 400 400
Interim Wellhead Prot. Area
Reservoirs 400 400
Drains (wat. supply/trib.) 50 100
Drains (intercept g.w.) 25 50
Drains (Other) Foundation 10 (5) 20 (10)
Drywells 20 25
1
Suction line 222(2)
2
100 feet is a minimum acceptable distance and no variance is allowed for a lesser distance (NA 5.02).
3
As defined in 310 CMR 10.55, 10.32, 10.54, and 10.30, respectively, pursuant to 15.211(3), also by NA
wetland bylaws