Loading...
HomeMy WebLinkAboutMiscellaneous - 1099 SALEM STREET 1/10/2018 (3) i North Andover Health Department (ommunity and EGonomi(Development Division ONSITE WASTEWATER SYSTEM CONSTRUCTION NOTES LOCATION INFORMATION ADDRESS: 1099 Salem Street Lot 1 MAP: 106.A LOT: 0049 INSTALLER: Robert Innis — LRC Builders DESIGNER: Craig Marchionda — Marchionda and Associates PLAN DATE: 05/17/2017 BOH APPROVAL DATE ON PLAN: 07/26/2017 INSPECTIONS TANK INSPECTION: 12/4/2017 DATE OF BED BOTTOM INSPECTION:11/28/2017 DATE OF FINAL CONSTRUCTION INSPECTION: 12/08/2017 DATE OF FINAL GRADE INSPECTION:1/10/2018 See email attached from Bob Innis SITE CONDITIONS M Contractor reports any changes to design plan N/A Existing septic tank properly abandoned New Construction Internal plumbing all to one building sewer M Topography not appreciably altered Comments: SEPTIC TANK M Building sewer in continuous grade, on compacted firm base N/A Cleanouts per plan ® Bottom of tank hole has 6" stone base M Weep hole plugged ® 1500 gallon tank has been installed H-20 loading M Monolithic tank construction ® Watertightness of tank has been achieved by visual testing M Inlet tee installed, centered under access port Z Outlet tee installed, centered under access port (gas baffle/effluent filter) f M 24 inch cover to within 6" of finish grade installed over one access port M Neoprene boots around inlet & outlet Comments: CONTROL PANEL ❑ Alarm & Pump are on separate circuits ❑ Alarm sounds when float is tripped ❑ Location of control panel: basement ❑ Alarm signal located inside: basement Comments: DISTRIBUTION-BOX Installed on stable stone base H-20 D-Box N/A Inlet tee (if pumped or >0.08'/foot) Z Hydraulic cement around inlet & outlets Z Observed even distribution ❑ Speed levelers provided (not required) Z Schedule 40 PVC Pipe Comments: SOIL ABSORPTION SYSTEM (General) Z Bottom of SAS excavated down to C soil layer, as provided on plan Z Size of SAS excavated as per plan Z Title 5 sand installed, if specified on plan Z 40 Mil HDPE barrier installed Z Laterals installed and ends connected to header (and vented if impervious material above) Z Elevations of laterals and chambers installed as on approved plan N/A Retaining wall (boulder/ concrete /timber/ block) ❑ Final cover as per plan Comments: 1 1/28/201 7 62 x 34 Brian LaGrasse - not executed down deep enough, needs to remove soil down to 31" Craig Marchonda will survey bottom of the bed and take pictures and certify, correct. SOIL ABSORPTION SYSTEM (Gravel-less Chambers) ❑ Brand and Model of Chamber: Standard Quick 4 Infiltrator Chambers ❑ Number of chambers per row: ❑ Number of rows (trenches): Comments: Total Chambers = FINAL GRADE 1/1012018 see email per Bob Innis ❑ Loamed ❑ Seeded ❑ Cover per plan Comments: DOCUMENTS NEEDED Certification of Installation Form submitted By engineer and signed and dated by Engineer and installer As-Built Plan BM = HR = HI SYSTEM ELEVATIONS ------------ _m._ ROD --------- ROD AS-BLT INVERT DESIGN INVERT ELEVATION ELEV ELEV Benchmark Building Sewer OUT 3.60 164.77 163.85 Septic Tank IN 3.70 164.67 163.53 Septic Tank OUT 3.87 164.50 163.28 Pump Chamber IN Pump Chamber OUT ............. Distribution Box IN 6.10 162.27 162.22 Distribution Box OUT 6.32 162.05 162.05 Lateral 1 TOP 6.38/6.64 Lateral I INVERT 161.99 / 161.73 161.99 161.75 Lateral 2 TOP 7.30 / 7.60 Lateral 2 INVERT 161.07 160.77 160.99 160.75 Lateral 3 TOP Lateral 3 INVERT Lateral 4 TOP Lateral 4 INVERT Lateral 5 TOP Lateral 5 INVERT Lateral 6 TOP Lateral 6 INVERT To of Chamber Bottom of Bed/Chamber SKETCH PLAN CRITICAL SETBACK DISTANCES Mark those distances checked in the field against the design plan and regulatory setback Tank SAS Sewer Property line 10 10 Cellar wall 10 20 Inground pool 10 20 Slab foundation 10 10 Deck, on footings, etc 5 10 Z Waterline 10 10 101 Z Private drinking well 75 1001 50 Z Irrigation well 75 100 Z Surface Water 25 50 Z Bordering Vegetated Wetland , Salt Marsh, Inland/Coastal Banka 75 100 Z Wetlands bordering surface water supply or trio. (in Watershed) 150 150 Trib, to surface water supply 325 325 Z Public well 400 400 Z Interim Wellhead Prot. Area Z Reservoirs 400 400 Z Drains (wat. supply/trib.) 50 100 Z Drains (intercept g.w.) 25 50 Z Drains (Other)Foundation 10(5) 20(10) Z Drywells 20 25 1 Suction line 222(2) 2' 100 feet is a ininitnurn acceptable distance and no variance is allowed for a lesser distance(NA 5.02). 3 As defined in 310 CMR 10.55, 10.32, 10.54,and 10.30,respectively,pursuant to 15.211(3), also by NA wetland bylaws 1/10/2018 Town of North Andover Mail-1099 and 1087 Salem St VER Michele Grant<mgrant@northandoverma.gov> 1099 and 1087 Salem Sti k W ..1..message ._ _._......._..._.. _.._._ ........_. .._ ....s i Robe' �rt 1rnis,<rokae�tinn% @yahoo.wm->,.-�"'— Tie, Jan 9, 2018 at 5:30 PM I Reply-To: Robert Innis <robertinnis@yahoo.com> To: Mgrant@northandoverma.gov To : North Andover Board of Health: As both the owner and contractor of the above lots, I certify they are properly graded and take responsibility for the final grades at and near the septic systems of each lot. Robert Innis LRC Builders LLC. i 1 https://mail.google.com/m ai1/u/0/?ui=2&ik=d4458df3d9&jsver=pkG7bi CEwP U.en.&view=pt&search=inbox&th=160dd42bccd 1463d&sim1=160dd42bccd... 1/1