HomeMy WebLinkAboutMiscellaneous - 136 OLD FARM ROAD 5/28/2015 s~
fff
CONSERVATION DEPARTMENT
Community Development Division
May 28, 2015
Michael Coughlin
29 Earnes Street
North Leading,TVJ-A 01864
1
136 Old Farm Road, North Andover j
Expansion of an existing deck plus stairs on Sano-tube Footings
Conservation Conditions of Approval,NACC #143
Pursuant to section 4.4.2 (A) of the North Andover Wetlands Protection Regulations,Michael
Coughlin of Summit Design.Build, acting on behalf of the owner, Devin.Martin, filed for a sinall
project:for work proposed at 136 Old Farm Road, North Andover. The proposed work includes the
expansion of an existing deck (w90 s.f.) on sono-tube supports. The proposed deck expansion is
approximately 51 feet froth the edge of Bordering Vegetated Wetland (BVW") as shown on tlxe
herein referenced plan. A small corner of decking will be cantilevered (no post/'footing) within 50'
of the BVW.
During the May 27, 2015 public sneering, the NAC.0 voted unanimously to approve this project. All
work shall conform to the following:
RECORD DOCUMENTS: Small Project Filing Including:
Application Checklist and narrative;
Plan Titled: "Site Plan"
Prepared for: Martin Residence 136 Old Farm Rd.,
North Andover, MA
Dated: 4/22/15
Project narrative prepared by Michael Coughlin, dated May 14,
2015;
Filing received: May 15, 2015
I
The following conditions are hereby mandated:
CONDITIONS:
1. Prior:to the start of construction the site contractor shall review the small project permit and be
aware of the wetland resource area and the limits of the proposed work.
i
J
1600 Osgood Street,Building 20,Suite 2-36,North Andover,Massachusetts 01845
Phone 978.688.1530 Fax 978.688.9542 Wets rvcvw.httl)://Iv-,vtv.to-,vnpfncrrthaiidover.c:om/coiiservel.htrn
2. Excess construction material shall be properly disposed of offsite and accepted engineering and
construction standards and procedures shall be followed in the completion of the project.
3. Upon completion of the approved project anal site stabilization,please contact the Conservation
Department for a final inspection.
4. This_permit_shall expire six months from the date of issuance.
Should you have any question or comments regarding the contents of this letter, please do not
hesitate to contact the undersigned at 978.688.9530 at your earliest convenience. Thanldng you in
advance for your anticipated cooperation with this matter.
Respectfully,
NORTH ANDOVER CONSERVATION DEPARTMENT
ell
Heidi Gaffney
Conservation Field Inspector
1600 Osgood Street,Building 20,Suite 2-36,North Andover,Massachusetts 01845
Phone 978.688.9530 Fax 978.688.9542 Web www.http://,,v\v-,v.to-,vjiofiiortli,,tndover.com/conservel.htm
AIA'�f c
s J
APPLICATION CHECKLIST— Small Prof c Noi.{H-i A.NPOVER
LsGONSERVUJON COMMIS)SI N
Project Location: 136 Old Farm Rd.
1
Applicant.-Summit Design Build Address: 29 Eames St N Pleading Phone:, 617-763-6613
General Re uireinents- 'tWTetland Protection R ulations:
Section 4.4-'The applicant has read and understands the applicable regulations
i
The applicant maintains that the project falls within the small project category below:
R A.Open slotted decks,without roofs,equal to or less than 300 square feet surface area,inclusive
of stairs and ramps,which are to be attached to an existing home,where soil disruption during
construction is limited to less than 50 square feet,and where no permanent soil alterations are
planned under the footprint of the deck.
El B.In kind replacement of existing decks,regardless of size.
C.Sheds or other outbuildings of less than 100 square feet,which are to be placed on footings,
not permanent foundations.
D.Sewer system connections as required by the Town of North Andover.
E. Unpaved pedestrian walkways (less,than four(4)feet wide)for private use or for public
access on conservation property.
® E.Patios less than 300 square feet,not requiring excavation or grading.
El C. Pruning of existing vegetation,planting of new native vegetation and gardening.
H. Fences and stone walls which do not alter the flow of surface waters nor alter wildlife habitat
or movement(does not include retaining walls).
El I. Conversion of non-permeable surfaces to permeable vegetated surfaces.
El J. In-kind replacement of existing basement bulkheads.
El K. Installation of a ramp for compliance with accessibility requirements.
i
� El L. Other similar projects of minimal impact,as determined by the North Andover Conservation
Commission.
0 The local"Wetland Bylaw filing fee of$25 has been included with this application.
Z A written narrative description/scope of work of the proposed project and potential impacts to all wetland
resource areas has been included.
Die applicant has identified and clearly marked all wetland resource area boundaries in the field.
I
Two (2) copies of a 1" =20' scale (or other as deemed appropriate by the Conservation Commission or
agent thereof) drawing showing existing and proposed conditions and the delineated wetland resource
areas (see plan requirements below for additional detail).
Effective 031212014 i
l;
LL IG L.Vi1JG1 V UL.LVIL�Vlll_I_lLLJJ1V11. ✓UL'G lJl lY1GCL11E�.
❑ The delineated resource area boundaries have been confirmed by the Conservation Department as
accurate.
Plan Requirements Section 4.4.3 B):
Certified and/or professionally prepared plans are not required. However,the North Andover Conservation
Commission or its designated agent shall have the final authority to determine whether the submitted
plans/drawings are adequate and include all pertinent information for review.
At a minimum,all plans submitted shall clearly and accurately show the present conditions and prMosed
work and depict the location of all wetland resource areas within 100' of the proposed work. All plans must
be signed and dated by the person who prepared them.
The Commission may also require the following information on the proposed plans in addition to the
aforementioned criteria where Vphcable:
❑ Location of any subsurface sewage disposal systems.
❑ Locations of any drainage structures.
❑ Locations of any easements,including but not limited to,drainage and utility easements.
❑ Locations of any open space boundaries if(e.g.if the lot is affected by the 50' open space boundary as
required in a Planned Residential Development(PRD)).
❑ Location and nature of all proposed alterations to the Buffer Zone Reso ce Area.
Signature of Applicant or Applicant's Representative p Date:
(TO WN USE ONLY)
❑ COMPLETE APPLICATION-The application meets the submittal requirements. Therefore,the
Conservation Department has prepared a written list of conditions necessary to protect any adjacent
wetlands for approval by the Conservation Commission.
This condition list shall be filed with the North Andover Conservation Department as NACC #
❑ INCOMPLETE APPLICATION-The following sections of the Wetland Protection Bylaw&/or
Regulations have not been complied with and as a result this Department is rejecting this incomplete
Application w/in two (2)business days from the date of receipt (Section 178.4 North Andover Wetland
Protection Bylaw). You may pick up this application and supporting plans at the Conservation Office and
re-file with the required supporting documents and information.
ElNOT A SMALL PROJECT-The North Andover Conservation Commission has determined that the
proposed project as submitted does not meet the small project criteria and hereby denies the application.
As such,a Request for Determination of Applicability(RDA)or a Notice of Intent(NOl)must be filed.
Reason(s)
Signature of Agent: Date:
Effective 03/2/2014 2
1
a
U M I T
es gn
29 Eames St.* North Reading,MA 01861. p:781.507-0135•f:781.507.8015
e:nlikc@scEb-in(-met%v:sdb-incnet
Date: May 14., 2015
rc
Jennifer Hughes
Conservation Administrator Iu4 t b Z'.3 i 5
Town of North Andover NORTI1 ANDOVER
1600 Osgood St. Suite 2035 GONSC(ilfAl'iUN CQMf�lISSION
North Andover,MA 01845
Ms. Hughes:
This letter is in regards to a proposed extension to the existing rear porch at 136 Old I+arm Rd. As outlined in die attached
drawings we would like to extend a portion of the deck 4' toward die real-of the property. The redesigned deck would have,
a new set of stairs to a landing platform then one more step to grade. The new stairs would intersect tike existing chain link
fence around the existing in-ground pool. This would allow the residents to put a gate across the strap going toward the pool,
while stili allowing Ihcir children access to their swing-set.on the other side of the fence. I have included a site plan with
wedand boundaries as they were staked out by Seekan-ip Environmental Consultants on May 6, 2015. The new clock
extension would require two new 12" sono tube footings and (our 8" that would be located outside the 50' no build zone.
The new stairs would require two 4-6"'x10"footings that would also be outside lice 50' no build zone. The deck is
approximately 5' above finished gi ade. The new deck quid stair design would greatly improve the safety of the residents'
yard while still allowing Idle access to their play area.
Sincerely,
Michael Coughlin
4) a)
'a ia 8
t
2�2 o
Z
S U/
29 Eames St,
N.Reading,MA 01864
P:781.507.0136
F:781.507.8015
♦ I �L 'YI'
Nlw 5/4"X6 CII-111
NORTHANDOVUi
Project No. 0415
Drawn By: _msc
Date: o4i22/15
Chocked By:
Revisions
514 7AS:
4'� Notes:
1919 1/2"
PLAN
S, 1/4^=1,,0•, o A- 1
PLAN