Loading...
HomeMy WebLinkAboutMiscellaneous - 9 TURTLE LANE 3/22/2018 i North Andover Health Department Community and Economic Development Division ONSITE WASTEWATER SYSTEM CONSTRUCTION NOTES LOCATION INFORMATION ADDRESS: 9 Turtle Lane MAP: 106.8 LOT: 104 INSTALLER: Kellett DESIGNER: Ben Osgood Jr. PLAN DATE: October 16, 2017 final revision date of November 6, 2017 BOH APPROVAL DATE ON PLAN: 11/22/2017 INSPECTIONS TANK INSPECTION: 12/1/2017 DATE OF BED BOTTOM INSPECTION: 12/5/2017 DATE OF FINAL CONSTRUCTION INSPECTION: 12/14/17 DATE OF FINAL GRADE INSPECTION: SITE CONDITIONS N/A Contractor reports any changes to design plan ® Existing septic tank properly abandoned ® Internal plumbing all to one building sewer ® Topography not appreciably altered Comments: SEPTIC TANK ® Building sewer in continuous grade, on compacted firm base N/A Cleanouts per plan ® Bottom of flank hole has 6" stone base Weep hole plugged 1500 gallon tank has been installed H-10 loading Monolithic tank construction Watertightness of tank has been achieved by visual testing ® Inlet tee installed, centered under access port j F71 Outlet tee installed, centered under access port (effluent filter) ® 24" inch cover to within 6" of finish grade installed over one access port ® Neoprene boots around inlet & outlet Comments: PUMP CHAMBER ® Bottom of tank hole has 6" stone base ® Weep hole plugged 1000 gallon Pump Chamber installed ® H-10 loading ® Monolithic tank construction Inlet tee installed, centered under access port ® Pump(s) installed on stable base ® Alarm float working ® Pump On/Off floats working ® Separate on/off floats ® Drain hole in pressure line ® 24" cover at final grade installed over pump access port ® Water tightness of tank has been achieved by Visual testing Neoprene boots around inlet & outlet Comments: CONTROL PANEL ® Alarm & Pump are on separate circuits ® Alarm sounds when float is tripped ® Location of control panel: outside ® Alarm signal located inside: outside Comments: DISTRIBUTION-BOX ® Installed on stable stone base H-20 D-Box Inlet tee (if pumped or >0.08'/foot) Hydraulic cement around inlet & outlets Observed even distribution N/A Speed levelers provided (not required) M Schedule 40 PVC Pipe Comments: 2" x 4" coupling about 4'-5' from D-box to transition from 2" force main to 4" SCH 40 PVC i f SOIL ABSORPTION SYSTEM (General) ® Bottom of SAS excavated down to C soil layer, as provided on plan ® Size of SAS excavated as per plan f ® Title 5 sand installed, if specified on plan { ® 40 Mil HDPE barrier installed ® Laterals installed and ends connected to header (and vented if impervious material above) ® Elevations of laterals and chambers installed as on approved plan N/A Retaining wall (boulder/ concrete /timber/ block) ❑ Final cover as per plan Comments: 20 x 30, 30 x 38 w/over dig FINAL GRADE M Loamed ® Seeded ® Cover per plan Comments: DOCUMENTS NEEDED ° ® Certification of Installation Form submitted By engineer and signed and dated by Engineer and installer ® As-Built Plan } BM = 100.00 HR = 2.57 HI = 102.57 SYSTEM ELEVATIONS -------------------- ROD AS-BLT INVERT DESIGN INVERT ELEVATION ELEV ELEV Benchmark Building Sewer OUT 94.5 Septic Tank IN 7.10 95.12 94.30 Septic Tank OUT 7.35 94.87 94.05 Pump Chamber IN 7.3794.85 94�00 .......------ Pump Chamber OUT 7.19 95.21 93.75 Distribution Box IN 5.61 96.61 96.54 ---------- Distribution Box OUT 5.80 96.42 96.37 Lateral 1 TOP 5.95 / 6.09 --------------- Lateral 1 INVERT 96.27 / 96.13 96.27 96.12 Lateral 2 TOP 5,89 / 6.08 Lateral 2 INVERT 96.33 / 96.14 96.27 96,12 Lateral 3 TOP 5.96 /6.08 Lateral 3 INVERT 96.26 / 96.14 96.27 96.12 Lateral 4 TOP 5,95 / 6.08 Lateral 4 INVERT 96.27 / 96.14 96.27 96.12 ------------- ------- ------------- .......... ----------------- Bottom of Bed 6.96 95.61 95.62 CRITICAL SETBACK DISTANCES Mark those distances checked in the field against the design plan and regulatory setback j Tank SAS Sewer ® Property line 10 10 -- ® Cellar wall 10 20 -- ® Inground pool 10 20 -- ® Slab foundation 10 10 -- Deck, on footings, etc 5 10 -- ® Waterline 10 1.0 10' ® Private drinking well 75 1.00, 50 Irrigation well 75 100 ® Surface Water 25 50 ® Bordering Vegetated Wetland , Salt Marsh, Inland/Coastal Batik 75 100 ® Wetlands bordering surface water supply or trib. (in Watershed) 150 150 ® Crib. to surface water supply 325 325 Public well 400 400 ® Interim Wellhead Prot. Area ® Reservoirs 400 400 ® Drains (wat. supply/trib.) 50 100 ® Drains (intercept g.w.) 25 50 ® Drains (Other) Foundation 10(5) 20(10) ® Drywells 20 25 1 Suction line 222(2) z 100 feet is a minimum acceptable distance and no variance is allowed for a lesser distance(NA 5.02). 3 As defined in 310 CMR 10.55, 10.32, 10.54, and 10.30,respectively,pursuant to 15.211(3), also by NA wetland bylaws