Loading...
HomeMy WebLinkAboutBuilding Permit #Exception - 1077 OSGOOD STREET 1/5/2016 LocationM No. Date S-1v • - T_IOWN OF NORTH ANDOVER Certificate of Occupancy $ Building/Frame Permit Fee $ Foundation Permit Fee $ Other Permit Fee $� TOTAL $ Checvo vv . r, '' `� Building Inspector li Model Number YSC060E3RHA**D00000000000000000000000000 Customer:AMT Project : Butcher Boy 5 ton Name : Butcher Boy 5 ton Y4C Unit function DX cooling,gas heat Unit efficiency Standard efficiency Airflow Convertible configuration Airflow Application Downflow Design Airflow 2000 cfm Evaporator rows 4.00 Each Fresh air selection Econ-dry bulb 0-100%w/bar relief Evaporator fin spacing 192 Per Foot 3ph Evaporator face area 7.71 sq ft Tonnage 5 Ton(060) Evaporator face velocity 259 ft/min Min.unit operating weight 613.0 Ib Cooling Entering DB 80.00 F Max.unit operating weight 824.0 Ib Cooling Entering WB 67.00 F Ent Air Relative Humidity 51.08% ASHRAE 90.1 Yes Ambient Temp 95.00 F Rated capacity(AHRI) 60.00 MBh Heating capacity High gas heat 3ph Heating EAT 70.00 F Voltage 208-230/60/3 Design ESP 1.000 in H2O Major design sequence E-R-410A Main Cooling Tonnage 5 Ton(060) Cooling Entering DB 80.00 F Cooling Entering WB 67.00 F Ent Air Relative Humidity 51.08% Ambient Temp 95.00 F Evap Coil Leaving Air Temp(DB) 57.73 F Evap Coil Leaving Air Temp(WB) 56.93 F Cooling Leaving Unit DB 59.88 F Cooling Leaving Unit WB 57.76 F Gross Total Capacity 62.27 MBh Gross Sensible Capacity 48.11 MBh Gross Latent Capacity 14.16 MBh Net Total Capacity 58.39 MBh Net Sensible Capacity 44.22 MBh Net Sensible Heat Ratio 0.76 Number Fan motor heat 3.88 MBh Dew Point 56.41 F Refrig charge(HFC-410A)-ckt 1 9.4 Ib Saturated Discharge Temp Circuit 1 121.07 F Saturated Suction Temp Circuit 1 52.21 F Wain Heating Heating capacity High gas heat 3ph Input Heating Capacity 130000.00 Btuh Output Heating Capacity 104000.00 Btuh Output Heating Cap.w/Fan 107884.07 Btuh Heating EAT 70.00 F Heating LAT 118.40 F Heating Delta T 48.40 F • . Pagel t TAWE �7 p V SUPPLY RETURN 3/4"-14 MPT DRAIN CONNECTION 23 9116" \411/4' r ISOMETRIC-PACKAGED COOLING Page 4 1� s INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER 26.0 Ib MOTORIZED OUTSIDE AIR DAMPER C D MANUAL OUTSIDEAIRDAMPER BAROMETRIC RELIEF OVERSIZED MOTOR BELTDRIVE MOTOR POWER EXHAUST 0 THROUGHT THE BASE ELECTRICAL/GAS(FIOPS) FNF MOUNTED CIRCUIT BREAKER(FIOPS) D UNIT MOUNTED DISCONNECT(FIOPS) POWERED CONVENIENCE OUTLET(FLOPS) D HINGED DOORS(FIOPS) B A HAILGUARD SMOKE DETECTOR,SUPPLY/RETURN PACKAGED GAS/ELECTRICAL NOVAR CONTROL CORNER WEIGHT STAINLESS STEEL HEAT EXCHANGER REHEAT ROOFCURB BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET t� 190.OID 190.OIb (E)LENGHT (F)WIDTH 686.OIb 693.OID O 156.OIb V 155.OIb 31" 19" N OTE: 1.CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY. 2.TO ESTIMATE SHIPPING WEIGHT ADD 5 LBS TO NET WEIGHT. 3.BASIC UNIT WEIGHT DOES NOT INCLUDE ACC ESSORYWEIGHT.TO OBTAIN TOTAL WEIGHT,ADD ACC ESSORYNET WEIGHT TO BASIC U NIT WEIGHT. 4.WEIGHTS FOR OPTIONS NOT LISTED ARE c5 LBS. 1 E F 0 0 PACKAGED GAS ELECTRICAL R IGGING AND CE NTE R OF GRAVITY Page 6 0 BAROMETRIC RELIEF HOOD CONOMIZER HOOD BAROMETRIC RELIEF HOOD 6 15/16" 4 8 1/6" ACCESSORY-BAROMETRIC RELIEF DAMPER HOOD Page 8 _ V Casing Unit casing shall be constructed of zinc coated,heavy gauge,galvanized steel.Exterior surfaces shall be cleaned,phosphatized,and finished with a weather-resistant baked enamel finish.Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM 13117.Cabinet construction shall allow for all maintenance on one side of the unit.Service panels shall have lifting handles and be removed and reinstalled by removing two fasteners while providing a water and air tight seal.All exposed vertical panels and top covers in the indoor air section shall be insulated with a cleanable foil-faced,fire-retardant permanent,odorless glass fiber material.The base of the unit shall be insulated with 1/8 inch,foil-faced, closed-cell insulation.All insulation edges shall be either captured or sealed.The unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 1 1/8 inch high downflow supply/return openings to provide an added water integrity precaution,if the condensate drain backs up.The base of the unit shall have provisions for forklift and crane lifting,with forklift capabilities on three sides of the unit. Unit Top The top cover shall be one piece construction or,where seams exist,it shall be double-hemmed and gasket-sealed. The ribbed top adds extra strength and enhances water removal from unit top. Filters Throwaway filters shall be standard on all units.Optional 2-inch MERV 8 and MERV 13 filters shall also be available. Compressors All units shall have direct-drive,hermetic,scroll type compressors with centrifugal type oil pumps.Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage.Internal overloads shall be provided with the scroll compressors. Dual compressors are outstanding for humidity control,light load cooling conditions and system back-up applications.Dual compressors are available on 7%-10 ton models and allow for efficient cooling utilizing 3-stages of compressor operation for all high efficiency models. Notes: Crankcase heaters are optional on YSC(036,048,060,072,090,102,120);standard on YHC(036,048,060,072,092,102,120). Indoor Fan The following units shall be equipped with a direct drive plenum fan design(T/YSC120E,TNHC092,102,120E).Plenum fan design shall include a backward-curved fan wheel along with an external rotor direct drive variable speed indoor motor.All plenum fan designs will have a variable speed adjustment potentiometer located in the control box.3-5 ton units(standard efficiency 3-phase or high efficiency 3-phase with optional motor)are belt driven,FC centrifugal fans with adjustable motor sheaves.3-5 ton units(1-phase or high efficiency 3-phase)have multispeed,direct drive motors.All 6-8%ton units(standard efficiency)shall have belt drive motors with an adjustable idler-arm assembly for quick-adjustment to fan belts and motor sheaves.All motors shall be thermally protected.All 10 tons and 7'/:-8'/z(high efficiency)have variable speed direct drive motors.All indoor fan motors meet the U.S.Energy Policy Act of 1992(EPACT). Outdoor Fans The outdoor fan shall be direct-drive,statically and dynamically balanced,draw-through in the vertical discharge position.The fan motor shall be permanently lubricated and shall have built-in thermal overload protection. Evaporator and Condenser Coils Internally finned,5/16"copper tubes mechanically bonded to a configured aluminum plate fin shall be standard.The microchannel type condenser coil is standard for the T/YSC 10 ton models and 7%ton high efficiency models.The microchannel type condenser coil is not offered on the 7%ton dehumidification model.Due to flat streamlined tubes with small ports,and metallurgical tube-to-fin bond,microchannel coil has better heat transfer performance.Microchannel condenser coil can reduce system refrigerant charge by up to 50%because of smaller internal volume,which leads to better compressor reliability.Compact all-aluminum microchannel coils also help to reduce the unit weight.All-aluminum construction improves re- cyclability.Galvanic corrosion is also minimized due to all aluminum construction.Strong aluminum brazed structure provides better fin protection.In addition,flat streamlined tubes also make microchannel coils more dust resistant and easier to clean.Coils shall be leak tested at the factory to ensure the pressure integrity.The evaporator coil and condenser coil shall be leak tested to 600 psig.The assembled unit shall be leak tested to 465 prig.The condenser coil shall have a patent pending 1+1+1 hybrid coil designed with slight gaps for ease of cleaning.A removable,reversible,double-sloped condensate drain pan with through the base condensate drain is standard. Controls Unit shall be completely factory-wired with necessary controls and contactor pressure lugs or terminal block for power wiring.Unit shall provide an external location for mounting a fused disconnect device.A choice of microprocessor or electromechanical controls shall be available. Microprocessor controls provide for all 24V control functions.The resident control algorithms shall make all heating,cooling,and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures.The control algorithm maintains accurate temperature control,minimizes drift from set point,and provides better building comfort.A centralized microprocessor shall provide anti-short cycle timing and time delay between compressors to provide a higher level of machine protection.24-volt electromechanical control circuit shall include control transformer and contactor High Pressure Control All units include High Pressure Cutout as standard. Page 10 " OM • w--AtrH OF •lifl 11111 , SHErA L FOL A .., S RFSr; f F' f E, W D NGVYE R0S` pNr`''` ST HAVER' b U 6= A .�1830-l:'.o`:=:;<::::::: :::< . P •4