Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Building Permit #1028-15 - 11 DANA STREET 6/9/2015
f � 1 t%ORT11 '9 �f _ BUILDING PERMIT a r�tkt t.q. � T" TOWN OF NORTH ANDOVER o :. APPLICATION FOR PLAN EXAMINATION '' Permit No#: WY Date Received �.y q°gwTeo�ea�45 SSACHUS� Date Issued: �o lc �� MPORTANT: Applicant must complete all items on this page LOCATIONS' - Print PROPERTY OWNER awnl ed X06c.-Y— Print 100 Year Structure yes no MAP 0 PARCEL:btc5- ZONING DISTRICT:.Historic District ye no Machine Shop Village ye no TYPE OF IMPROVEMENT PROPOSED USE Residential Non- Residential ❑ New Building ❑ One family ;KAddition ❑ Two or more family ❑ Industrial ❑Alteration No. of units: ❑ Commercial ❑ Repair, replacement ❑Assessory Bldg ❑ Others: ❑ Demolition ❑ Other ❑ Septic ❑Well ❑ Floodplain 0 Wetlands ❑ Watershed District Water/Sewer DESCRIPTION OF WORK TO BE PERFORMED: j goz-��- D i Identification- Please Type or Print Clearly OWNER: Name: �ie4l -1f;'0A.0,2e Phone: 9;W 77/-1 93,2Z Address: // De4la— 15� Contractor Name: 1 reS Phone: 0,4�y Address: U C$6 < <o Supervisor's Construction License: OC � a - Exp. Date: " Home Improvement License: w. _S Exp. Date: 10 -- z 3-t ARCHITECT/ENGINEER Phone: Address: ,i��,9� � Reg. No. FEE SCHEDULE:BULDING PERMIT.$12.00 PER$1000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PER S.F. Total Project Cost: $ 1 SC)A00 • w FEE: $ t Check No.: Receipt No.: 42��2dp, NOTE: Persons contracting with unregistered contractors do not have access to the guaranty fund I ignature of Agent/Owner Signature of contract*., a Location 0A 111A No. Date • - TOWN OF NORTH ANDOVER Certificate of Occupancy $ Building/Frame Permit Feed_ Foundation Permit Fee $ Other Permit Fee $ W TOTAL $ Check# Q� uilding Inspector Plans SubmittedA Plans Waived ❑ Certified Plot Plan ❑ Stamped Plans ❑ TYPE'OF SEWERAGE DISPOSAL Public Sewer Tanning/Massage/Body Art ❑ Swimming Pools ❑ Well ❑ Tobacco Sales ❑ Food Packaging/Sales ❑ Private(septic tank,etc. ❑ Permanent Dumpster on Site ❑ THE FOLLOWING SECTIONS FOR OFFICE USE ONLY INTERDEPARTMENTAL SIGN OFF - U FORM PLANNING & DEVELOPMENT Reviewed On Signature_ COMMENTS CONSERVATION Reviewed on AS Sic inature COMMENTS A)b HEALTH Reviewed on Siqnature e COMMENTS Y Zoning Board of Appeals: Variance, Petition No: Zoning Decision/receipt submitted yes Manning Board Decision: Comments hnservation Decision: Comments Ater& Sewer Connection/Signature& Date Driveway Permit DEV Town Engineer: Signature: Located 384 Os ood Street FIRE;DEPARTMENT - Temp Dumpster on site yes no Located at 124 Main Street Fire Department signature/date COMMENTS Dimension Number of Stories: Total square feet of floor area, based on Exterior dimensions. Total land area, sq. ft.: ELECTRICAL: Movement of Meter location, mast or service drop requires approval of Electrical Inspector Yes No DANGER ZONE LITERATURE: Yes No MGL Chapter 166 Section 21A—F and G min.$100-$1000 fine NOTES and DATA— (For department use) i ❑ Notified for pickup Call Email Date Time Contact Name I Doc-Building Pennit Revised 2014 Building Department The following is a list of the required forms to be filled out for the appropriate permit to be obtained. Roofing, Siding, Interior Rehabilitation Permits ❑ Building Permit Application ❑ Workers Comp Affidavit ❑ Photo Copy Of H.I.C. And/Or C.S.L. Licenses ❑ Copy of Contract ❑ Floor Plan Or Proposed Interior Work ❑ Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit Addition Or Decks ❑ Building Permit Application Li Certified Surveyed Plot Plan ❑ Workers Comp Affidavit ❑ Photo Copy of H.I.C. And C.S.L. Licenses ❑ Copy Of Contract ❑ Floor/Cross Section/Elevation Plan Of Proposed Work With Sprinkler Plan And Hydraulic Calculations (If Applicable) ❑ Mass check Energy Compliance Report (If Applicable) ❑ Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit New Construction (Single and Two Family) ❑ Building Permit Application ❑ Certified Proposed Plot Plan ❑ Photo of H.I.C. And C.S.L. Licenses ❑ Workers Comp Affidavit ❑ Two Sets of Building Plans (One To Be Returned) to Include Sprinkler Plan And Hydraulic Calculations (If Applicable) ❑ Copy of Contract ❑ Mass check Energy Compliance Report ❑ Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg. Permit In all cases if a variance or special permit was required the Town Clerks office must stamp the decision from the Board of Appeals that the appeal period is over. The applicant must then get this recorded at the Registry of Deeds. One copy and proof of recording must be submitted with the building application Doc:Building Permit Revised 2014 Dear Zoning Board Of Appeals Department: Gerald Brown;Albert P. Manzi, 3rd ESQ; Ellen P. McIntyre; D. Paul Koch, Jr. ESQ; Allan E. Cuscia; Douglas Ludgin; Deney D. Morganthal; Nathan J. Weinreich (.recently sent you a letter in which I pointed out the reasons why the new construction you approved at 11 Dana Street, North andover is a House and not an "In -Law Apartment". I would appreciate a response to the following questions: 1. How does the Zoning Board determine that a given set of plans/drawings is an "in-Law" or a "house" ? 2. Is the size of the House Lot considered? Please note the Lot sizes in this area are extremely small. 3. Has any member(s) of the Zoning Board or the Building Inspector dropped by the 11 Dana Street construction sight? If so, what is your reaction? Is it a "House" or an "In-Law Apartment". 4. Why were not the neighbors, especially the adjacent neighbors, notified that the plans for the "In-law" were changed from the re-furbish of the garage to the present construction? 5. Has the Board noticed the massive equipment, man-power, material needed for this so called "In-Law Apartment"? 6. Has the Board considered the ramifications of these so called "In-Laws" have on the area? In a few years when the present owners move away, the new owners will turn these "In-Laws" into a TWO family. 7. How did a TWO family (across the Street from 11 Dana Street) with a garage "Mysteriously" turn into a THREE family? 8. How is the Zoning Board going to deal with this Monkey See Monkey do mentality that is occurring in this area? Easy, learn to say NO to so called "In- Law Apartments" that are really "Houses" that will become TWO families in the future. Please, Zoning Board do not be an accomplice to down grading /actually destroying the neighborhood. If you do not know how to say NO, then please retire so that someone who does can take your place. Thank you for reading this letter and I encourage your response. Please drop by 11 Dana St. and see what is going on in the neighborhood. Sincerely, Hope ee you 5oonlill �✓�l�i4 oh @ n J. agala, 1 Dan Street, North Andover MA JUL 3 I l' BOARD OF APPEALS Dear Zoning Board Of Appeals Department: Gerald Brown;Albert P. Manzi, 3rd ESQ; Ellen P. McIntyre; D. Paul Koch, Jr. ESQ; Allan E. Cuscia; Douglas Ludgin; Deney D. Morganthal; Nathan J. Weinreich I.recently sent you a letter in which I pointed out the reasons why the new construction You approved at 11 Dana Street, North andover is a House and not an "In -Law Apartment". I would appreciate a response to the following questions: 1. How does the Zoning Board determine that a given set of plans/drawings is an "in-Law" or a "house" ? 2. Is the size of the House Lot considered? Please note the Lot sizes in this area are extremely small. i 3. Has any member(s) of the Zoning Board or the Building Inspector dropped by the 11 Dana Street construction sight? If so, what is your reaction? Is it a "House" or an "In-Law Apartment". 4. Why were not the neighbors, especially the adjacent neighbors, notified that the plans for the "In-law" were changed from the re-furbish of the garage to the present construction? 5. Has the Board noticed the massive equipment, man-power, material needed for this so called "In-Law Apartment"? 6. Has the Board considered the ramifications of these so called "In-Laws" have on the area? In a few years when the present owners move away, the new owners will turn these "In-Laws" into a TWO family. 7. How did a TWO family (across the Street from 11 Dana Street) with a garage "Mysteriously" turn into a THREE family? 8. How is the Zoning Board going to deal with this Monkey See Monkey do mentality that is occurring in this area? Easy, learn to say NO to so called "In- Law Apartments" that are really "Houses" that will become TWO families in the future. Please, Zoning Board do not be an accomplice to down grading /actually destroying the neighborhood. If you do not know how to say NO, then please retire so that someone who does can take your place. Thank you for reading this letter and I encourage your response. Please drop by 11 Dana St. and see what is going on in the neighborhood. Sincerely, Hope-gee you 5oonl!Il thnJ., agala, D 1 Dan Street, North Andover MA JUL 3 t J BQARD OF APPEALS Ciofolo, Angela From: Leathe, Brian Sent: Thursday,July 23, 2015 3:39 PM To: Ciofolo,Angela Subject: 11 Dana As requested I dropped by 11 Dana Street. The Plans appear to reflect what is being built an approximately 24x36 single car garage with an in-law apartment. Brian Leathe Local Building Inspector Town of North Andover 1600 Osgood Street Bldg. 20 Suite 2035 North Andover, MA 01845 Phone 978.688.9545 Fax 978.688.9542 Email bleathe@townofnorthandover.com Web www.TownofNorthAndover.com 1 July 19,2015 - TO: Albert P.Manzi,III, Esq., Ellen P. McIntyre,D. Paul Koch,Jr.,Esq., Allan E. Cuscia, Douglas Ludgin, Deney D. Morganthal,Nathan J. Weinreich BOARD OF APPEALS Dear Members of the Zoning Board of Appeals, I am writing with regard to the house being built at 11 Dana Street. Earlier this year I was asked to sign a letter of support for the property owners, and I was given the impression that an addition was being proposed to the existing structure. If you were to walk or drive down Dana Street now, as I have,you would see that what is being built is no less than a second house on the property. It is my understanding that the Zoning Board of Appeals reviewed the proposed construction project, and gave its approval to the plans as they were submitted to the Board,without requesting any changes. It is also my understanding that the primary role of the Zoning Board of Appeals is to serve as the guardian of the character of the neighborhoods and town of North Andover. I signed the letter of support under the assumption that the proposed construction at 11 Dana Street was to be an in-law apartment or"family suite" (per the wording on the agenda of the April 14 Board meeting).I certainly was not expecting that a second house would be build on the property. I feel that in this particular instance,the Board failed in its mission of protecting the character and property values in the Dana-Dewey-Harold Street neighborhood,and I feel that an unfortunate precedent may have been set. I hope that in the future,the Board will take its role and its mission much more seriously when considering proposed construction projects such as the one going on now at 11 Dana Street. Thank you very much. JE U, W TO: Zoning Board Of Appeals: JUL U' `" Gerald Brown;Albert P. Manzi,3rd, ESQ; Ellen P. McIntyre; D. Paul Koch, Jr. ESQ;Allan E. Cuscia; Douglas Ludgin; p APPEALS BOARDDeney D. Morganthal; Nathan J. Weinreich. When does a so called "in-Law Apartment" become a house? How do you tell the difference between building an "In-Law Apartment" and building a house? Let's see if I can help you: 1. When a Breeze-Way separates the existing house and the new construction, RED FLAG, It's a house. 2. When the "Footprint" of the new construction is close to one-half or more of the "Footprint" of the existing house, RED FLAG, it's a house. 3. When the new construction roof line is as high or higher than the existing house, RED FLAG, it's a house. 4. When the new building is too large for the existing Lot, Red FLAG, it's a house. 5. When the new construction has a Cathedral Ceiling, Red FLAG, it's a house. The Zoning Board Of Appeals recently approved the building of a structure at 11 Dana Street, North Andover MA, 01845 that includes all 5 items stated above. This area of North Andover is Zoned for one family homes because of the small lot sizes. If and when you are in the area of 11 Dana Street , North Andover located off Waverly Road near the Thomson School, Please view the new construction you approved as an "in-Law apartment", it's a house!!!! When is the Zoning Board Of Appeals going to STOP "rubber stamping" all new construction under the guise of "in-Law Apartments"? Where was the Building Inspector? Doesn't he/she get an opportunity to view the plans? When your friendly next door neighbor is not shown the new construction plans and is out of town when "The Plans" are presented before the "Board Of Appeals", RED FLAG, it's a house!!!! P.S. We love And respect our neighbors at 11 Dana Street, But, it is obvious the feeling is not mutual. P.S. 2 : If you do drop by 11 Dana Street, please stop in at 1 Dana St. and I will show you a REAL In-Law Apartment also, I will show you a 3 family across the Street you approved. in rely, I---- Y-f_� j 3 ' - glaze--- John J. Fifa al g a, 1 Dana Street, North Andover, MA, 01845 Enter construction cost for fee cal - North Andover Fee Cakulation Construction Cost $ 130,000.00 m $ - $ 540.00 Plumbing Fee $ 195.00 Gas Fee 100 comm. $ 100.00 Electrical Fee $ 195.00 Total fees collected $ 1,030.00 11 Dana Street 1028-15 Addition pC� C� C� � dC� July 19,2015 ' TO: Albert P. Manzi,III,Esq., Ellen P. McIntyre, D. Paul Foch,Jr.,Esq.,Allan E. Cuscia, Douglas Ludgin, Deney D. Morganthal,Nathan J. Weinreich gCYARD OF APPEALS Dear Members of the Zoning Board of Appeals, I am writing with regard to the house being built at 11 Dana Street. Earlier this year I was asked to sign a letter of support for the property owners, and I was given the impression that an addition was being proposed to the existing structure. If you were to walk or drive down Dana Street now, as I have,you would see that what is being built is no less than a second house on the property. It is my understanding that the Zoning Board of Appeals reviewed the proposed construction project, and gave its approval to the plans as they were submitted to the Board,without requesting any changes. It is also my understanding that the primary role of the Zoning Board of Appeals is to serve as the guardian of the character of the neighborhoods and town of North Andover. I signed the letter of support under the assumption that the proposed construction at 11 Dana Street was to be an in-law apartment or"family suite" (per the wording on the agenda of the April 14 Board meeting).I certainly was not expecting that a second house would be build on the property. I feel that in this particular instance,the Board failed in its mission of protecting the character and property values in the Dana-Dewey-Harold Street neighborhood, and I feel that an unfortunate precedent may have been set. I hope that in the future,the Board will take its role and its mission much more seriously when considering proposed construction projects such as the one going on now at 11 Dana Street. Thank you very much. Ciofolo, Angela From: Leathe, Brian Sent: Thursday,July 23, 2015 3:39 PM To: Ciofolo,Angela Subject: 11 Dana As requested I dropped by 11 Dana Street. The Plans appear to reflect what is being built an approximately 2436 single car garage with an in-law apartment. Brian Leathe Local Building Inspector Town of North Andover 1600 Osgood Street Bldg. 20 Suite 2035 North Andover, MA 01845 Phone 978.688.9545 Fax 978.688.9542 Email bleathe@townofnorthandover.com Web www.TownofNorthAndover.com 1 Y D a .c� � ad � TO: Zoning Board Of Appeals: JUL I 1 Gerald Brown;Albert P. Manzi,3rd, ESQ; Ellen P. McIntyre; D. Paul Koch, Jr. ESQ;Allan E. Cuscia; Douglas Ludgin; OF APPEALS Deney D. Morganthal; Nathan J. Weinreich. When does a so called "in-Law Apartment" become a house? How do you tell j the difference between building an "In-Law Apartment" and building a house? Let's see if I can help you: 1. When a Breeze-Way separates the existing house and the new construction, RED FLAG, It's a house. 2. When the "Footprint" of the new construction is close to one-half or more of the "Footprint" of the existing house, RED FLAG, it's a house. 3. When the new construction roof line is as high or higher than the existing house, RED FLAG, it's a house. 4. When the new building is too large for the existing Lot, Red FLAG, it's a house. 5. When the new construction has a Cathedral Ceiling, Red FLAG, it's a house. The Zoning Board Of Appeals recently approved the building of a structure at 11 Dana Street, North Andover MA, 01845 that includes all 5 items stated above. This area of North Andover is Zoned for one family homes because of the small lot sizes. If and when you are in the area of 11 Dana Street , North Andover located off Waverly Road near the Thomson School, Please view the new construction you approved as an "in-Law apartment", it's a house!!!! When is the Zoning Board Of Appeals going to STOP "rubber stamping" all new construction under the guise of "in-Law Apartments"? Where was the Building Inspector? Doesn't he/she get an opportunity to view the plans? When your friendly next door neighbor is not shown the new construction plans and is out of town when "The Plans" are presented before the "Board Of Appeals", RED FLAG, it's a house!!!! P.S. We love And respect our neighbors at 11 Dana Street, But, it is obvious the feeling is not mutual. P.S. 2 : If you do drop by 11 Dana Street, please stop in at 1 Dana St. and I will show you a REAL In-Law Apartment also, I will show you a 3 family across the Street you approved. Sincerelyiag�a, John J. Fla, 1 Dana Street, North Andover, MA, 01845 I July 19, 2015 TO: Albert P. Manzi,III,Esq.,Ellen P. McIntyre,D. Paul Koch, Jr., Esq.,Allan E. Cuscia, Douglas Ludgin, Deney D. Morganthal,Nathan J. Weinreich Dear Members of the Zoning Board of Appeals, I am writing with regard to the house being built at 11 Dana Street. Earlier this year I was asked to sign a letter of support for the property owners, and I was given the impression that an addition was being proposed to the existing structure. If you were to walk or drive down Dana Street now, as I have,you would see that what is being built is no less than a second house on the property. It is my understanding that the Zoning Board of Appeals reviewed the proposed construction project, and gave its approval to the plans as they were submitted to the Board,without requesting any changes. It is also my understanding that the primary role of the Zoning Board of Appeals is to serve as the guardian of the character of the neighborhoods and town of North Andover. I signed the letter of support under the assumption that the proposed construction at 11 Dana Street was to be an in-law apartment or"family suite" (per the wording on the agenda of the April 14 Board meeting). I certainly was not expecting that a second house would be build on the property. I feel that in this particular instance,the Board failed in its mission of protecting the character and property values in the Dana-Dewey-Harold Street neighborhood, and I feel that an unfortunate precedent may have been set. I hope that in the future,the Board will take its role and its mission much more seriously when considering proposed construction projects such as the one going on now at 11 Dana Street. Thank you very much. i i j i I -RIDGE VENT(A8 REQUIRED) ,,,,1/Y GWB ON 1 X 3 STRAPPING INSULATION HEADER:2-2 X 10 TYPICAL.UNLESS NOTED OTHERWISE RECESSED TMpIM EAVES DEAL: LIGHT FIXTURE FAWA S 80FW TO MATM DOffnNO CONTINUOUS SOFFIT VENT DOUBLE TOP PLATE METAL DRIP EDGE ICENVATER SHIELD TYPICAL EXTERIOR WALL: SIDING TO MATCH EXISTING BUILDING WRAP 1/2'CDX PLYWOOD SHEATHING 3/4'TBG PLYWOOD. 2 X 8 AT 18"O.C. NAIL 8 GLUE TO FRAMING R-20 INSULATION VAPOR BARRIER FLASH 1/Y GWB + FINISH IST FLOOR FINISH 1ST FLOOR + — — --V.I.F.: FINAL FINISH GRADE AT EXTERIOR FINISH ORADE PROPOSED FINISH FLOOR ELEVATION CRAWL SPACE VENTED THROUGH SYSTEM LOCATED IN FOUNDATION PERIMETER T OF NEW ADDITION. �T SEE MAIN HOUSE CROSS SECTION. .ORGANIC WATERPROOFING CRAWL FFRA%FM ROWE RESIDENCE 11 DANA STREET NORTHANDOVER, MA WALL1140■114P DAM VMS i i RIDGE BEAM 5V COX PLYWOOD 2-2X12 RIDGE VENT(AS REQUIRED) ROOF SHEATHING 1/2'GWB ON 2 X 8 RAFTERS AT 18'O.C. 1 X 3 STRAPPING ASPHALT SHINGLES R-38 INSULATION RAFTER TO TOP PLATE HEADER:2-2 X 10 TYPIC FRAMING CONNECTOR. 12 sRECESSED 2 X 4 Q 100 O.C. LIGHT FIXTURE VENTED SOFFIT ER TO TOP PLATE IING CONNECTOR. / NEW OPENING / BEAM:2-2 X 8 INTO EXISTING DWELLING 314"T$G PLYWOOD. NAIL&GLUE TO FRAMII sp FLASH E. BRIDGING AT FINISH CENTER SPAN ++ FINISF 2X 10 AT 18'O.G. R-30 INSULATION ,,; FINISH GRADE 16 CRAWL SPACE Cl ASS I ":` 0. CRAWL SPACE VENTED THROUGH SYSTEM LOC VAPOR BARRIER IN FOUNDATION PERIMI 2#5 REBAROF NEW ADDITION. OP�BOT. — — T SEE MAIN HOUSE CROS — — — REMOVE ALL ORGANIC WATERPROOFING 20'X 10' V.I.F.ADEQUATE SOILS FROM CRAWL POURED CONCRETE SOIL BEARING SPACE AREA FOOTING CAPACITY TYPICAL CROSS SECTION B - B i I RIDGE BEAM 5V CDX PLYWOOD 2-2 X 12 ROOF SHEATHING 2 X 8 RAFTERS AT 18"O.C. I ASPHALT SHINGLES RAFTER TO TOP PLATE FRAMING CONNECTOR. 12 2X40180O.C. VENTED SOFFIT RAFTER TO TOP PLATE FRAMING CONNECTOR. Tom.OIL I DETAL: BEAM:2.2 X 8 SILL SM R BOLTS AT 4'0 C. SSEAL FOAM RAULATION DOUBLE 2 X 8 TREATED UL CONTINUOUS RUM JOIST TREATED WOOD FRAME WEATHER RESISTANT DECI(ING FINISH C3RAD2 -10 1 E .. i y•�: 20"X 10' 7v.I POURED CONCRETE S0 FOOTING CA TYPICAL CRO CONTINUOUS POUREI NOTE: FOOTING&F BUILDER/OWNER TO INSTALL FOUNDATION INCOMPLIANCE WITH THE APPROVED ZBA DOCUMENTS. CONCRETE& i PROVIDE i THROB PROVIDI AT FO IPROVIDE GROUTED REBAR IDOWEL ATTACHMENT BETWEEN INEW/EXISTING FOUNDATIONS 30"X 30"X 12" I =TE FOOTING I A.CONCRETE "EEL COLUMN I BEAM POCKET EXISTING GARAGE FOUNDATION. V.I.F. STRUCTURAL INTEGRITY. ® I L GARAGE 00 G8 WITH TIN I ALIGN F I EXI8ITNG SLAB TO REMAIN. BEARING WALL ABOVE REMOVE AS REQUIRED FOR I NEW FOUNDATION.PROVIDE ISLAB REPAIR I \"- I i I .. .. ...... ...... .... .... .... .. ...... I I I PROVIDE FOUNDATION WALL OPENING AS REQUIRED FOR NEW I ( D OVERHEAD DOOR UNIT W a Ia F --1 — — z T. BASEMENT PLAN ROWE RESIDENCE 11 DANA STREET NORTH ANDOVER, MA PROVIDE IDOWEL j NEW/EXI I I 30"X 30"X 12" POURED CONCRETE FOOTING 3 1/2"DIA.CONCRETE I FILLED STEEL COLUMN BEAM P CONTINUOUS POURED CONCRETE FOOTING&FOUNDATION. E L I Gi I Q BEAM POCKET' I ALIGN FOOTINGS WITH I Q BEARING WALL ABOVE CONCRETE SLAB I I I I I I 7 ..... I II i I PROVIDE CRAWL SPACE VENTING 01 THROUGH ACCESS OPENING. I ( I a ALTERNATE: PROVIDE CRAWL SPACE VENTS AT FOUNDATION PERIMETER. ( I I d I — 2 PROVIDE CRAWL SPACE ACCESS. USE EXISTING BASEMENT ENTRY OPENING. POURED CONCRETE FOOTING--."// AND PIER AT ROOF SUPPORT. B. i PROPOSED EXISTING i r ',•.•:.i:. ... gin' n•,.>i i' •" •:1�' I \ I_ TREA WOOD STAIRS I &LAN NG. SLIDING DOOR \ I \ l- TREATED WOOD LANDING&STAIRS INSTALL FIREPLACE VENTING IN ACCORDANCE WITH CODE STEP BOTTOM FOUNDATION At TO ACHIEVE PR LEFT ELEVATION (PROPOSED) f I :D / EXISTING_� FI 2ND FLOOR + — — i FINIWI IST FLOOR + — — IEXISTING FINISH GRADE VARIES. V.I.F.ACTUAL CONDITIONS. i SLOPE FINISH GRADE TO DRAIN. —TREA WOOD STAIRS NEW BASEMENT &LANDING. BULKHEAD ENTRY STEP BOTTOM OF NEW FOUNDATION AS REQUIRED TO ACHIEVE PROPER BEARING. TT ELEVATION Pumm F[ ROWE RESIDENCE (PROPOSED) 11 DANA STREET NORTH ANDOVER, MA sc�:�K••ra a►�e�one EXHAUST FAN :.::::. HARD DUCTED TO EXTERIOR FULL HEIGHTWALL.: ••'•••'•'• RATED&INSULATED SIS'TYPE X GWB R-20 INSULATION SHOWER: CERAMIC TILE WATERPROOF MEMBRANE BELOW PITCH TO DRAIN ••• MINIMUM CURB HEIGHT EXISTING CONCRETE SLAB TO REMAIN. V.I.F PITCH TO DRAIN STRUCTURAL CONDITION '•'•'•' STEP DOWN. : V.I.F. REMOVE EXISTING CONCRETE SLAB .'•'.'•'•'•'•'.'• AS REQUIRED FOR NEW FOUNDATION. : REPLACE SLAB TO MATCH EXISTING. ..... — — — — ~ — , DRILL&DOWEL NEW SLAB–>EXISTING. GARAGE MINIMUM 20 FROMSLAS TO TOP FOUNDATION. :.:•:I:•:.:.:.:. ELECTRICAL PANEL. :�:.•: VERIFY LOCATION WITH ELECTRICIAN .. &UTILITY. •'•'•i•'•'•'•''' OVERHEAD DOOR: SIZE&STYLE PER OWNER + SEE APPROVED ZBA DOCUMENT FOR LOCATION OF PROPOSED ADDITION. AM ABOVE D EATED WOOD DECK N 0 I a z N EXISTING DRIVEWAY: V.I.F. GRADING&DRAINAGE 10 FINISH GRADE ,,---NEW WINDOW. FIRST FLOOR PLAN MATCH EXISTING (PROPOSED) REMOVE EXISTING ENTRY STAIRS&ROOF STRUCTURE. PATCH TO MATCH EXISTING. PL"FM ROWE RESIDENCE 11 DANA STREET NORTH ANDOVER, MA ecatF.�K•■tea a�e�orte r EI CEILING AT BATH&CLOSET: 2X8AT18'O.C. R-W INSULATION 1/2'GWB ON 1 X 3 STRAPPING N 'ANDERSEN'GLIDING PATIO DOOR NOMINAL V WIDE UNIT TREATED WOOD DECK&STAIRS. V.I.F. SIZE. RAILIG PER CODE. ARCHITECTURAL FIREPLACE. FP 'BURNGREEN"MENDOTA"MODEL. INSTALLER TO PROVIDE VENTING IN ACCORDANCE WITH CODE. Ll -11 4- STEP(S)TO FINISH GRADE I I T I I g _ B II DECK (EXISTING) 4 X 4 REMOVE EXISTING C WINDOW.'IN-FILL' TO MATCH EXISTING WALL 0 B� BEDROOM NEW BASEMENT • BULKHEAD ENTRY CLE LIVING ROOM DINING ROOM AAPLAN 2-AW31 aaa EQUAL EQUAL 1r-W i i . . .. .••• W CLGI I . .... .. CEILING AT BATH 8 CLQSET: I I 2X8AT160O.C. R,38 INSULATION �,A I. 2'GWB ON 1 X 3 STRAPPING � ATH I . . . .. B . . BEDROOM I I N 0 :.:.:.:.:.:.:. SKYUGHT` PANTRY r .. Q SINK 8 VANITY Z ..... LOAD BEARING WALL GLASS BLOCK II SLIDING PATIO DOOR. �� • IOMINAL V WIDE UNIT Q 'STEF KITCHEN V.I.F. IECK&STAIRS. V.I.F.SIZE ® :':•:c• — — UG PER CODE. REFERENCE AMILY ROOM KITCHEN :•::I:':..:: G) VENDOR DESIGN 4 X 4 POST .. .. : ' SINK ECTURAL FIREPLACE. FP 10MENDOTR MODEL. i 'p REF ''•:I:•:.:.:.'. TO PROVIDE VENTING )RDANCE WITH CODE. TVVM` 411/ STEP(S)TO FINISH GRADE I I RIDGE i i BEAM ABOVE I BEAM , I B - B I I (ABOVE) i i I TREATED WOOD DECK 6' SLDG UP II DRII 4 X 4 ( I Lliil7c7CLU — 1r L w-T II REMOVE EXISTING WINDOW.9N-FILL' TO MATCH EXISTING WALL BATH 4 X 4 POST BEDROOM PANTRY Q STEP(8)TO FINISH GRADE UF NEW WINDOW MATCH EXISTI I REMOVE EX r ENTRY STAII STRUCTURE — — — PATCH TO M DINING ROOM KITCHEN - - - i li i i i OHNE 0 FINISH 2ND FLOOR i FINISH IST FLOO i i i I FR( I I Enter construction cost for fee cal - North Andover Fee Calculation Construction Cost $ 130,000.00 m $ - $ 1,560.00 Plumbing Fee $ 195.00 Gas Fee 100 comm. $ 100.00 Electrical Fee $ 195.00 Total fees collected $ 2,050.00 11 Dana Street 1028-15 on 6/9/2015 Demo Exisitng Garage Build addition with one stall garage ttORTH Town of 2 t EAndover o ,� oh ver, Mass, A- coc IcNlWICK �J,,4 ADA'�TED PP���S aS U BOARD OF HEALTH JI Food/Kitchen PERMIT T LD Septic System THIS CERTIFIES THAT ......., 4...... .. .O.aj'r........................................................................ BUILDING INSPECTOR / Foundation has permission to erect .......................... buildings on .� 1�,..t.7//��AIX.... to be occupied as .........,� ,�.X... U� ( ................................................... Chimney............... ......... .�............ ..l.�r�.. Chimney provided that the person accepting this permit shall in every res ect conform to the terms of the application Final on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection, Alteration and Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR Rough VIOLATION of the Zoning or Building Regulations Voids this Permit. Final PERMIT EXPIRES IN 6 MONTHS ELECTRICAL INSPECTOR UNLESS CONSTRUCTION STARTS Rough Service ........................ .... o ^?vr..................... Final B ILDING INSPECTOR GAS INSPECTOR Occupancy Permit Required to Occupy.Buildin Rough i Display in a Conspicuous Place on the Premises — Do Not Remove Final G No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector." Burner Street No. Smoke Det. AC40R"® DATE(MM/DDIYYYY) CERTIFICATE OF LIABILITY INSURANCE 6/9/2015 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER NAME: Sandi Munroe M P ROBERTS INS AGCY INC PHONE (978) 683-8073 FAX A/C No E.O. AIC No:(978) 683-3147 1060 Osgood Street E-MAIL s:sandi@mprobertsinsurance.coIR North Andover, MA 01845 INSURER(S) AFFORDING COVERAGE NAIC# INSURER A:AMERICAN EUROPEAN INS CO I INSURED D & H HOMES I INSURER B INSURER C PO BOX 522 INSURER D: NORTH ANDOVER, MA 01845 INSURER.E INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDIL s BR P L Y FF OLICY EXP LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER MM/DDN MM/DD/YYYY LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1_X00,000 CLAIMS-MADE F_x1 OCCUR PREMISES Ea occurrence $ 100,000 SKP2001014 10 06/30/14 06/30/15 MED EXP(Any one person) $ 5,000 A SKP2001014 11 06/30/15 06/30/16 PERSONAL&ADV INJURY $ 1,000,000 GENT AGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE $ 2,000,000 X POLICY❑PE� " LOC PRODUCTS-COMP/OP AGG $ 2,000,000 OTHER: $ AUTOMOBILE LIABILITYSINGLE LIMIT $ Ea accident ANYAUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED AUTOS AUTOS BODILY INJURY(Per accident) $ NON-OWNED PROPERTY A A HIRED AUTOS AUTOS Per accident $ $ UMBRELLA LIAB _ OCCUR EACH OCCURRENCE $ EXCESS LIAB 11CLAIMS-MADE AGGREGATE $ DED RETENTION$ $ WORKERS COMPENSATION AND EMPLOYERS LIABILITY YIN STATUTE I EORTH- ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMBER EXCLUDED? ❑ N/A E.L.EACH ACCIDENT $ (Mandatory in NH) E.L. DISEASE-EA EMPLOYE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE TOWN OF NORTH ANDOVER THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. BUILDING DEPT. NORTH ANDOVER, MA 01845 AUTHORIZED REPRESENT VEh I ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD25(2014101) The ACORD name and logo are registered marks of ACORD i EXISTING PROPOSED RIDGE VENT _ ASPHALT SHINGLES - - -- - - - - - - - - - - - - - - - - GUTTER&D.S. TRY ROOF-----,,, OOF - (OWNER OPTION) MATCH EXISTING; SIDING,TRIM, EAVE DETAIL NEW OVERHEAD DOOR. —--- -- SIZE&87YL.E PER OWNER. IING FINISH GRADE (CRETE PIER RT COLUMN. I i NEW FOUNDATION EXISTING FOUNDATION RAWFW ROWE RESIDENCE 11 DANA STREET NORTH ANDOVER, MA WNUMM•■114P GATE amma EXISTING PROPOSED OUTLINE OF ADDITION(BEYOND) RIDGE VENT ENTRY ROOF .. LOOR ® ® ROOF SUPPORT COLUMN. LOO TREATED WOOD STAIRS$LANDINGw POURED CONCRETE PIER UNDER ROOF SUPPORT COLUMN. II FRONT ELEVATION NEW FOUNDATION (PROPOSED) i i CUSTOM FIXED WINDOW��)UNITS. � FINISH 1STL OGm- +,; ..r i,;, .• „.+._ y...:�;•+ .fir.. :.::t:.,°':^:.•. �r� .:t.r. FINI8HORADE .t; ,;:a.. t::y:;%:r..•.•.,• *'�' ,ti;•„,.•.�•: • . POURED CONCRETE FOUNDATION SUDING DOOR T'REAT'ED WOOD LANDING S STAIRS I PROPOSED ADDITION RIDGE VENT SOLATUBE - - - - - - - - - - - - - - - - - - - -- 7--A SIDING&TRIM O MATCH EXISTING. I EXISTING FOUNDATION NEW FOUNDATION AWNING STYLE WINDOWS. REA i PROPOSED ADDITION EXISTING DWELLING(BEYOND) i RIDGE VENT ATUBE FM .. ._ -177 7_-- - - - - - - - - - - - - - - - - - - - -- - --- -- -_ ---- - EE tF iffll -I L9 EXISTIN( NEW FOUNDATION NEW TREATED WOOD LANDING&STAIRS(BEYOND) AWNING STYLE WINDOWS. i E i � REAR ELEVATION F I,I (PROPOSED) i i i I EXISTING DWELLING(BEYOND) r 70 Jill FINISH 2ND FLOOR PH=-- I-- f + FINISH IST %004-% EXISTING DECK WOOD EYOND) NEW BASEMENT BULKHEAD ENTRY N rFK"FM RIOWE RESIDENCE 11 DANA STREET NORTH ANDOVER, MA WAL&W m 110 or►T�QIdoHO y w ---- - ---- - FINISH IST FLOOR (DING TO MATCH MOWING XI8TINQ FOUNDATION TO REMAIN IN FFPUMFM ROR( WEWE RESIDENCE 11 DANA STREET NORTH ANDOVER, MA a�K•-rar omea�orta i I EXISTING PROPOSED i I ROOF SUPPORT COLUMN"",/ OLUMN FINWH GRADE SIDING TO MATCH EXISTING POUREDN Co CRETE PIER DER ROOF SUPPORT COLUMN. � LJ �- TREATED WOOD STAIRS EDUSTING FOUNDATION TO REMAIN EXISTING FINISH GRADE VARIES. V.I.F.ACTUAL CONDITIONS. SLOPE FINISH GRADE TO DRAIN. RIGHT ELEVATION (PROPOSED) I I EXISTING PRC FINISH LOOK I I I IN 8 TALL NEW WINDOW AT AHANlDC I,INED DOOR LOCATION. FINISH ST FLOOR ROOF SUPPORT COLUMN fiJ I I FlN18H GRADE POURED CONCRETE PIER REMOVE EXI8Ti NG UNDER ROOF SUPPORT COLUMN. ENTRY STRUCTURE L J PATCH WALL TO MATCH EXISTING. TREATED WOOD STAIRS-� EXISTING FINISH GRADE V V.I.F.ACTUAL CONDI SLOPE FINISH GRADE TO RIGI (F DQE VENT —DOUBLE TOP PLATE UNEQUAL SLOPED ROOF VAULTED CEILING; IVTCHEN, FAMILY ROOM,BEDROOM R-8 INSULATION HEADER:2-2 X 10 TYPICAL UNLESS NOTED OTHERWISE TYPICAL EXTERIOR WALL: SIDING TO MATCH EXISTING BUILDING WRAP 1/2'CDX PLYWOOD SHEATHING 2X8ATlir O.C. R-20 INSULATION VAPOR BARRIER 1/2'GWB Z ALTERNATE CRAWL SPACE VENTING; INSTALL OPERABLEISCREENED CRAWL SPACE VENTS 2 FINISH 1 ST FLOOR FINISH GRADE ;.-,-"o-WATERPROOFING EXISTING FINISH GRADE VARIES. V.I.F.ACTUAL CONDITIONS. ' SLOPE FINISH GRADE TO DRAIN. b GANIC AWL = A V- ROWS RESIDENCE 11 DANA STREET NORTH ANDOVER, MA C FRAMING CONNECTOR. RAFTER TO HATE 5V CDX PLYWOOD ROOF SHEATHING 2X 12 AT 16.O.C. ASPHALT SHINGLES 8 RAFTER TO TOP PLATE FRAMING CONNECTOR. � LOAD BEARING WALL .YPIC&EAVES DETA�: 2 X S AT IW O.C. X 6 BLCOKING FASCIA A SOFFIT TO MATCH EXISTING � � WALL STIFFENEF CONTINUOUS SOFFIT VENT AT 1/3 POINTS DOUBLE TOP PLATE 1/Y GWB ON METAL DRIP EDGE 1 X 3 STRAPPING r"ATER SHIED 3/4 r&G PLYWOOD. NA L 8 GLUE TO FRAMING PERIMETER'RIBBON JOIST TYPICAL.S&L DETAIL; INSULATION FULL DE ANCHOR BOLTS AT 4%0 C. BRIDGING AT OF FRAMING. R-30 M! BILL SEAL FOAM INSULATION DOUBLE 2 X 8 TREATED SLL CENTER SPAN CONTINUOUS RIBBON JOIST ' 2X 10 AT IV O.C. ' CRAWL SPACE SOLID BLOCKING Z 2#6 REBAR tb j BEAM FINISH GRADE .�.,�";� � �+ �. (SLOPE TO DRAIN �? TOP&BOT. 31/2"DIA CONCRETE CLASS STEEL PIPE COLUMN VAPOR BARRIER VCONCRETE FOOTINGS: 30'X30"X1Y V.I.F.ADEQUATE — — — 4"THICK CONCRETE SLAB SOIL BEARING CAPACITY. - - - - - TYPICAL ALL FOUNDATIONS. REMOVE AL SOILS FROP, SPACE ARE TYPICAL CROSS SECTIO i i i FRAMING CONNECTOR. RIDGE VENT RAFTER TO PLATE DOUBLE TOP PLATE 518'CDX PLYWOOD ROOF SHEATHING UNEQUAL SLOPED ROOF VAULTED CEILING; KITCHEN,FAMILY ROOM, BEDRI 2X 12 ATlir O.C. R-38 INSULATION , kSPHALT SHINGLES 1 8 i TOP PLATE HEADER:2-2 X 11 3NNECTOR. LOAD BEARING WALL TYPICAL EX SIDING TO N E AL- .,� 2 X 6 AT 18'O.C. X 8 BLCOIONG BUILDING W 3TM / WALL STIFFENEFm 112'CDX PL) PLATE,LATE AT 1/3 POINTS 2X6AT18'1 1PY GWB ON R-20 INSULA HH&D 1 X 3 STRAPPING 314 SG PLYWOOD. VAPOR BART NA L ds GLUE TO FRAMING112'OWB PERIMETER'RIBBON JOIST" ALTERNATE CRAWL SPA M-1 INSULATION FULL DEPTH 3 INSTALL OPERABLE/M BRIDGING AT OF FRAMING. R-30 MIN. CRAWL SPACE VENTS LL CENTER SPAN 3T f I FINISH 1ST F, 2X10 AT Ir O.C. CRAWL SPACE 2 SOLID BLOCKING FINISH CRAG Z :• Nf , BEAM 2#6 REBAR WATERPROOFING TOP&BOT. '-3 l/2'DIA.CONCRETE FIy CLAN 1 STEEL PIPE COLUMN VAPOR BARRIER CONCRETE FOOTINGS. — — — 30'X30'X12' 1� . 4'THjb ICK CONCRETE SLAB .- REMOVE ALL ORGANIC SOILS FROM CRAWL SPACE AREA + TYPICAL CROSS SECTION A - A �7 ZONING TABLE: ZONING DISTRICT. R4 REQUIRED PROVIDED MAX. HEIGHT 35 FEET < 35 FEET OP Day MIN. LOT FRONTAGE: 100 FT 100.00' t a MIN. LOT AREA: 12,500 S.F. 10,000 S.F. a Alim MIN. FRONT SETBACK 30 FT 23.1 FT � MIN. SIDE SETBACK 15 FT 5.5 FT MIN. REAR SETBACK 30 FT 6.9 FT NORTH ANDOVER ZONING RECORD OWNER: ARD OF APPEALS ASSESSOR MAP 15, LOT 53 FRANK & HEATHER ROWE are 11 DANA STREET NORTH ANDOVER, MA 01845 DEED REF- SK 2971 PG: 44 FOR REG/S7RY OF DEEDS USE ONL Y I PLAN REFERENCE: BOOK.• 173 PA GE. 600 TAX MAP 15 LOT 41 TAX MAP 15 LOT 40 APPROVED 20_ #20 HAROLD STREET #10 HAROLD STREET N/F DAVID J. LICCIARDi EX. 1 ST. N/F CUR71S COGLIANO N86'00'00"E GARAGE 100.00' m oo LOT AREA= 5.7' 10,000 S.F. EX. 1 ST. 0° o GARAGE "} ori N 36r EX. 1 STALL GARAGE (19'x25') TO BE RAZED. 0 12.4 I I PROP. ADDITION TO BE BUILT WITHIN DECK EX. GARAGE POOTPRINT AND EXTEND AS 3 I 30.0 SHOWN. ADDITION SHALL NOT 8E o N 1 CLOSER THAN 6.9 FEET TO REAR LOT LINE Lu 0 z o Mo EXISTING I EX. ROOFED PLATFORM + STEPS TO BE REMOVED to 1 STY i_ W J z STRUCTURE OI 0� wN I U) Q w 20.3' ( i--W T E Jd 24.5 I -5 #1 DANA S . o Z^> I Ex. Bit. I p► ^N Q X Q I Conc. l �o o Driveway lQooi � oI x z N oQ a cn z ' S86,00,00"w I ' 100.00' DANA STREET GRAPHIC SCALE SCALE. 1"=20' FEET 20 0 10 20 "I HEREBY CERTIFY THAT THE PROPERTY LINES SHOWN ON THIS PLAN ARE THE LINES DIVIDING Il DANA STREET EXIS7TNG OWNERSHIPS, AND THE LINES OF THE STREETS AND WAYS SHOWN ARE THOSE OF PUBLIC OR PRIVATETR PLOT Pl" OF zam S SETS OR WAYS ALREADY ESTABLISHED, AND THAT NO NEW LINES FOR LOCATED IN DIVISION OF EXISTING OWNERSHIP OR FOR NEW NORTH ANDOVER MASS. WAYS ARE SHOWN AND THIS PLAN CONFORMS TO THE RULES AND REGULA77ONS OF THE REGISTRY OF DEEDS." /ESSEX COUNTY • i I DECLARE, TO THE BEST OF MY PROFESSIONAL KNOWLEDGE, INFORMA7/0N, AND BELIEF, THAT PREPARED FOR THIS PLAN WAS PREPARED IN ACCORDANCE FRANK ROWE WITH THE RULES AND REGULA 77ONS OF THE REGISTERS OF DEEDS SCALE.• 1"= 20DATE: FEB. 24, 2015 Ct az PREPARED BY SULLIVAN ENGINEERING GROUP, LLC 22 MWIff VERNON ROAD BOXFORD, MITA 01921 �. 116 (978) 352-7871 L��jr PAUL Fl zkw SHEET No. 1 OF 1 5