Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Building Permit #814 - 1101 TURNPIKE STREET 6/20/2010
f V40RTH q O tao n •y0 TOWN OF NORTH ANDOVER APPLICATION FOR PLAN EXAMINATION t r ♦ 9'o _ 9SSACHUSE� Permit NO: Date Received Date Issued: IMPORTANT: Applicant must complete all items on this page LOCATION ( I©1 —Tf7-)Y*- (lam 11*l ) Print PROPERTY OWNER is ?1 oNl, Cil C� ,�,,. t4,1s. JFAVK,--7P--4g,) Print MAP NO.: PARCEL: ZONING DISTRICT: TYPE AND USE OF BUILDING HISTORIC DISTRICT YES ❑ TYPE OF IMPROVEMENT PROPOSED USE Residential Non- Residential ❑New Building ❑ One family ❑ Addition ❑ Two or more family ❑ Industrial ❑ Alteration No. of units: ❑ Repair, replacement ❑ Assessory Bldg ❑ Commercial ❑ Demolition ❑ Moving(relocation) VOther Others: V7?4.1 Foundation only DESCRIPTION OF WORK TO BE PREFORMED F�l1t 1 C �tP � C G �► . FA --S- PW— /STM 5 Gtr e9- 9 a--)O 4mo /V-F,4 (-46W7, Identification Please Type or Print Clearly) OWNER: Name: t-4A-T1CA+4t. (9Zl® Phone:,450ppo 30G 91113 Address: 26 ReISEA424C,44 MWE f WPS-1 3C CX)6N . MA 615962- CONTRACTOR Name: CYt4 EJ441 RaJME4TA U 66ZACI✓S Phone('7&' Z44 Address: 1 (:;o OSCd.4 i�Jf. T -,1.�-I�.;I MA Supervisor's Construction License: -- t2e4 p)e Exp. Date: Z- Z� BS Home Improvement License: Exp. Date: ARCHITECT/ENGINEER Name: Phone: 11 Address: Z6 f-f,;:%k i + -1,• x'1 ,rU Reg. No.� 1�7 FEE SCHEDULE:BULDING PERMIT:$10.00 PER$1000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PER S.F. Total Project Cost :$ 57.coo x10.00=FEE:$ 51bg Check No.: Q�=)599 Receipt No.: Page I of 4 TYPE OF SEWARGE DISPOSAL Swimming Pools ❑ i 11Tannng/Massage/Body Art ❑ Public Sewer Tobacco Sales ❑ Food Packaging/Sales ❑ Well ❑ Permanent Dumpster on Site ❑ Private(septic tank,etc. ❑ Electric Meter location to project NOTE: Persons contracting with unregistered contractors do not have access to the guaranty fund Signature of Agent/Owner Signature of Contractor Plans Submitted ❑ Plans Waived ❑ Certified Plot Plan ❑ Stamped Plans ❑ THE FOLLOWING SECTIONS FOR OFFICE USE ONLY INTERDEPARTMENTAL SIGN OFF-U FORM DATE REJECTED DATE APPROVED PLANNING & DEVELOPMENT ❑ ❑ []Water Shed Special Permit ❑ Site Plan Special Permit ❑ Other COMMENTS DATE REJECTED DATE APPROVED CONSERVATION ❑ ❑ COMMENTS DATE REJECTED DATE APPROVED HEALTH ❑ ❑ COMMENTS Zoning Board of Appeals: Variance,Petition No: Zoning Decision/receipt submitted yes Planning Board Decision: Comments Conservation Decision: Comments s� Water&Sewer connection/Signature,& D� Driveway Permit Temp Dumpster on site yes—no( Fire Department signature/date �� Building Setback(ft.) Front Yard Side Yard Rear Yard Required Provided Required Provides Required Provided DIM ENS ION Number of Stories: Total square feet of floor area,based on Exterior dimensions. Total land area,sq. ft.: NOTES and DATA—(For department use) Page 3 of 4 Doc:INSPECTIONAL SERVICES DEPARTMENT:BPFORM05 Created JMC.Jan.2006 Building Department The following is a list of the required forms to be filled out for the appropriate permit to be obtained. Roofing, Siding, Interior Rehabilitation Permits ❑ Building Permit Application ❑ Workers Comp Affidavit ❑ Photo Copy Of H.I.C. And/Or C.S.L. Licenses ❑ Copy of Contract ❑ Floor Plan Or Proposed Interior Work Addition Or Decks ❑ Building Permit Application ❑ Surveyed Plot Plan ❑ Workers Comp Affidavit ❑ Photo Copy of H.I.C. And C.S.L. Licenses ❑ Copy Of Contract ❑ Floor/Crossection/Elevation Plan Of Proposed Work With Sprinkler Plan And Hydraulic Calculations (If Applicable) ❑ Mass check Energy Compliance Report (If Applicable) New Construction (Single and Two Family) �f Building Permit Application ❑ Certified Proposed Plot Plan N/Thoto of H.I.C. And C.S.L. Licenses /Workers Comp Affidavit t� Two Sets of Building Plans (One To Be Returned) to Include Sprinkler Plan And /Hydraulic Calculations (If Applicable) r� Copy of Contract ❑ Mass check Energy Compliance Report In all cases if a variance or special permit was required the Town Clerks office must stamp the decision from the Board of Appeals that the appeal period is over. The applicant must then get this recorded at the Registry of Deeds. One copy and proof of recording must be submitted with the building application Doc:INSPECTIONAL SERVICES DEPARTMENT:BPFORM05 Page 4 of 4 Location No. �� Date C d� r NORTIy TOWN OF NORTH ANDOVER - Certificate of Occupancy $ ��a",• t<� Building/Frame Permit Fee $ s�cwus Foundation Permit Fee $ Other Permit Fee $ TOTAL $ Check # 4 3 8 Building Inspector F NORTH own of No. it dover, Mass., LA COCHIC HEWICK ADRATED `S BOARD OF HEALTH PERMIT T , D Food/Kitchen Septic System BUILDING INSPECTOR THIS CERTIFIES THAT......... . �... . .. �... Foundation AA has permission to erect. ......................... b ildin>e, n .... ..Q/....... �i .L. f....... Rough to he occupied as.... or �0., 404 0... �.. ...�l...... ��1��...��.� `.......... �i/y Chimney provided that the ers if a-cce in thi �iermit shal ' res ect conform to the terms a licatio on fileinP P Pt g �P P PP Final this office, and to the provisions of the Codes an �w `atin he Inspectio bra ion Const of Buildings in the Town of North Andover. F !aY0 . PLUMBING INSPECTOR VIOLATION of the Zoning or Building Regulations Voids this Permit. Rough r Final PERMIT EXPIRES IN 6 MONTHS UNLESS CONSTRUCTI TARTS ELECTRICAL INSPECTOR Rough ................. ......... .. . . .... ..... Service BUILDING INSPECTOR Final Occupancy Permit Required to Occupy Building GAS INSPECTOR Rough Display in a Conspicuous Place on the Premises — Do Not Remove Final No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. Burner Street No. SEE REVERSE SIDE Smoke Det. i AGREEMENT a This Agreement, made and entered into on the date when signed by the party f signing last in time, by and between Massachusetts Electric Company, a Massachusetts corporation, with principle offices at 25 Research Drive, g Westborough, Massachusetts 01582; Niagara Mohawk Power Corporation, a New York corporation, with offices at 300 Erie Boulevard West, Syracuse, New York p 13202; The Narragansett Electric Company, a Rhode Island corporation, with offices ,k���.,, . at 280 Melrose Street, Providence, Rhode Island 02901; each a National Grid C company (each an Owner), and CYN Oil Corporation, d.b.a. CYN Environmental f Services (Contractor), a Massachusetts corporation, having its principal place of ko business at 100 Tosca Drive, Stoughton, Massachusetts, 02072, for the Work identified as: NATIONAL GRID COMPANIES r' PETROLEUM STORAGE TANK REMOVAL AND REPLACEMENT PROJECT VARIOUS LOCATIONS Q MASSACHUSETTS AND RHODE ISLAND P.O. # 0000027995 arr ARTICLE - SCOPE OF WORK The Contractor hereby agrees to provide all materials, equipment, apparatus, tools, labor, Services, and facilities and to perform all the Work and do all things necessary ry owt, to remove numerous underground and above ground petroleum tanks and install several new above ground tanks for Regions A g , B, and C in Massachusetts and , Rhode Island and associated Work; all in accordance with this Agreement. ` r. . s" ARTICLE - CONTRACT DOCUMENTS }` The following documents, including all attached schedules, appendices, exhibits or other attachments thereto, are incorporated by reference as if fully set forth herein, ,1 and are hereinafter referred to collectively and individually as the "Contract Documents" or the "Agreement": 1. Agreement 2. Terms and Conditions 00700, dated Revised 8/20/03 3. Schedule A, Supplemental Conditions, dated August 29, 2005 4. Schedule B, Specification as titled "Specification for Petroleum k Storage Project ", dated May 2005 5. Schedule C - Milestone Schedule, dated August 25, 2005 6. Schedule D - Price Schedules Alternate Price Schedule Unit Price Schedule Labor Rates ' Equipment Rates 7. Schedule E, Safety Requirements 8. Schedule F, Environmental Requirements 9. Schedule G, Contractor's Insurance Requirements 10. Schedule H, Release and Bond Forms ARTICLE - SCHEDULE The Work to be performed under this Agreement shall be in accordance with the Milestone Schedule, a copy of which is incorporated herein by reference as Schedule C. I/ 71i Send Original Invoice to: Send Copy Invoice & Backup to: Niagara Mohawk Power Corp. Michael Miller Accounts Payable Dept.- Building C-1 Building B-1 300 Erie Boulevard West 300 Erie Boulevard West Syracuse, NY 13202 Syracuse, NY 13202 ARTICLE - NOTICES Notices required or permitted under this Agreement shall be addressed to: Contractor: Owner: CYN Environmental Services National Grid USA Service Company 100 Tosca Drive 25 Research Drive Stoughton MA 02072 Westborough MA 01582 Attention: J. Steven Tucci Attention: Michael Rook A copy of any such notice shall also be forwarded to Procurement Agent and to Field Construction Coordinator. ARTICLE - ENTIRE AGREEMENT i This Agreement, including all Contract Documents, constitutes the entire Agreement between the Owner and the Contractor, with respect to the Work specified, and all previous representations relative thereto, either written or oral are hereby annulled and superseded. No modification of any of the provisions of this Agreement shall be binding unless in writing and signed by a duly authorized representative of each party hereto. 4 • ��e �e�rn-manueczlt� e-���Gaytac�u.fe�1 BOARD OF BUILDING REGULATIONS License: CONSTRUCTION SUPERVISOR Ekk Number: CS 071942 Birthdate: 02/27/1968 Expires: 02/27/2008 Tr.no: 19252 Restricted: 00 PAUL F REIDY JR 9-6 ROBIN CIRCLE NORTON, MA 02766 Commissioner � Civil Design Affidavit Permit No. To the Commissioner, North Andover Building Department, Re: Installation of above ground storage tank I certify that to the best of my knowledge, information and belief, the plans and computations accompanying the attached application concerning the locus at: 1101 Turnpike Street.North Andover.MA are in accordance with the requirements of the Massachusetts State Building Code — 780 CMR and all other applicable laws, regulations, statutes and ordinances. MICHAEL Engineer—MA Reg.No o E. x ROOK w CIVIL 4' a No.30463National Grid hoc C'ISTOX Company Name • FSS�OMA ��V 25 research Dr.Westborough MA 01581 Address (508) 389-9113 Date — Then personally appeared the above name t kat 1 —Roo�{ (Print name) and made oath that the above statement by him/her is true. Before me, ' 2 8t�r COconwoeNh of Maeeadaal� My@SSMOMVM �sion El�IfN ber 15,2010 R�i3�P•.A.a. t;' �?� 4�e: �.� t'_ r• fir. q„., _� ,�;, 's ,.'S� cfR. ry�� 1...t)Y: ��r n� c�. � - .�>v�.�i,�t' i i I FP6(rev.3/00) 6. 2kx 6&& RlyCGf,G, 6�ow, Q"0/ 775 5 PERM' City or Town —:�Y r � � � SIG SAFE NUMBER DateD—v G '...:qt a -ate: Permit Number(if applicable) In accordance with the provisions of ivCt� '_4b, ovi. A in this permit is granted -ull nar ,person,Firm or Corporation) for ,t�s -,5"W r J F (777-7 Restrictions: at ' (Give location by street and no.,or describe in such manner as to provide adequate identification of location) Fee Paid $ (S-0 — This Permit wilexpire on —�— Signature of Official Granting Permit Title This permit must be conspicuously posted upon the premises { i OP ID g DATE(MMIDD/YYYY) ACORD CERTIFICATE OF LIABILITY INSURANCE CYNEN-1 06/05/06 PRODUCER THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE Capstone Insurance LLC HOLDER.THIS CERTIFICATE DOES NOT AMEND,EXTEND OR One Boston Place - 39th Floor ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. Boston MA 02108 j Phone: 617-619-3300 Fax:617-619-3301 INSURERS AFFORDING COVERAGE NAIC# INSURED INSURER A: American International C n Oil Corporation INSURERB: r Dy/B/A Cyn Environmental INSURER C: Services 100 Tosca Drive INSURER D: Stoughton MA 02072 INSURER E: COVERAGES THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED.NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS, POLICY EFFECTIVE POLICY EXPIRATION LTR NSR TYPE OF INSURANCE POLICY NUMBER DATE MMIDDIYY DATE MM/DDIYY) LIMITS GENERAL LIABILITY EACH OCCURRENCE $ 1000000 A X COMMERCIAL GENERAL LIABILITY R/O OF 7551164 05/30/06 05/30/07 PREMISES(ED ao�ccurence) $50000 CLAIMS MADE OCCUR MED EXP(Any one person) $5000 i A X Prof. Liability R/0 7551164 - CLAIMS MADE 05/30/06 05/30/07 PERSONAL BADV INJURY $1000000 I X Incudes XCU GENERAL AGGREGATE $2000000 j GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMPIOPAGG $1000000 POLICYFX JECT LOC i AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT A X ANY AUTO R/O OF 7551166 05/30/06 05/30/07 (ES accident) $1,000,000 ALL OWNED AUTOS MCS— 90 INCLUDED BODILY INJURY $ SCHEDULED AUTOS (Per person) I A X HIREDAUTOS R/O 7551166 05/30/06 05/30/07 BODILY INJURY $ A X NON-OWNED AUTOS R/0 7551166 05/30/06 05/30/07 (Per accident) PROPERTY DAMAGE $ (Per accident) GARAGE LIABILITY AUTO ONLY-EA ACCIDENT $ ANY AUTOOTHER THAN EA ACC $ AUTO ONLY: AGG $ I EXCESSIUMBRELLA LIABILITY EACH OCCURRENCE $ 10,000,000 A }{ OCCUR CLAIMS R/0 7551165 05/30/06 05/30/07 AGGREGATE $10,000,000 DEDUCTIBLE $ X RETENTION $10,000 TATL WORKERS COMPENSATION AND X TORY LIMITS ER A EMPLOYERS'LIABILITY R/O OF WC 9685828 05/30/06 05/30/07 E.L.EACH ACCIDENT $1 000 OOO ANY PROPRIETOR/PARTNERIEXECUTIVE OFFICER/MEMBER EXCLUDED? E.L.DISEASE-EA EMPLOYEE $1,000,000 If yes,describe under SPECIAL PROVISIONS below E.L.DISEASE-POLICY LIMIT $1,000,000 OTHER A Pollution NH R/0 PLS1951620 05/30/06 05/30/07 1,000,000 !. A Pollution MA R/O PLS2678439 05/30/06 1 05/30/071 5,000,000 DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES I EXCLUSIONS ADDED BY ENDORSEMENT/SPECIAL PROVISIONS i i i CERTIFICATE HOLDER CANCELLATION PROOFOF SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,THE ISSUING INSURER WILL ENDEAVOR TO MAIL 30 DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT,BUT FAILURE TO DO SO SHALL Proof of Coverage IMPOSE NO OBLIGATION OR LIABILITY OF ANY KIND UPON THE INSURER,ITS AGENTS OR REPRESENTATIVES. AUTHORIZED REPRESENTATIVE ACORD 25(2001108) ©ACORD CORPORATION 1988 000, EXISTING KIM TO BE REMOVED AND RESET ON NEW TAPE(fit EQUIPMENT t7Fittan dimensions an then drowtngs sho9 PAD AS SHOWN.BELOW. REFER TO THE This preadonS over seined action wit Tnb araw(nq N iesuW k con}rctkn wiin LAYOUT DETAIL THIS DWG FOR FURTHER the projat mfereMed below.No other use DETAILS Is outhorited without the srprese written TRlkl(WASH BAY perminkm of CYN Envirommentd Servke. This drawing shod.not be used for const- ELECTRIC ROOM APPROXIMATE LOCATION OF E EMSTING ruction purposes until approved by the AIR SUPPLY LINE.EXPOSE TE INTO project rnonogd. THE EXISTING LIND LINE OUTSIDE OF THE BUILDING AS RUN NEW LINE TO UNDERNEATH THE AS SHOWN. 4 EXISTING WALL MOUNT LIGHT TYPICAL FOR FURTHER DETAIL TO THE 3 OF THREE AS SHOWN OPERATING LAYOUT DETAIL BELOW. CONDITION NOT KNOWN. 2 I ENGINEERS COMMENTS 1; i� Rf\ TO'PANEL - ASION DATE 11i'I — >I�1F1(t _'_.. ---i REVISIONS PRO;IE • .: d _ :• tt'f(� j 1�•ai� < -� _ - !Y • n •• 's �,,r_ _ 1 5'-0' ! •.. i - 5'-0' '- :p•_ d •-• - � i i .. �•►'�l1 d •.- OP- _.• i • . -d• � { MOUNT OVERFLL ALAR11�THAT • • • `b• 1! �� d• < •r I ° _e N$l i t?' THE OPERATOR HAS AN UNOBSTRUCTED Y� •.. <. _:,., jf� . ,, nationalyid d<• :'.• e- ( .•. ! tQ d •- •• • • i t{ A VIEW OF THE ALARM Uri 44'MINIMUM, ;1j11 PROPOSED LOCATION FOR THE i i j i® �-{� `� ^i EXISTING AIRTOWER TO BE MOUNTED LJ t i t I j 1 LOCAiKXN TANK ANDPAD 1101 i ,I TURNPIKE ROAD-ROUTE 114 PROPOSED AREA LIGHT LOCATION. BASE TO 8E -- -- s��y, (REFER TO FUC FURTHER DETAIL ) NORTH ANDOVER, UA 24'ABOVE FINISHED GRADE j I,r� o.a. o Q o o a Q.o. IW3 i 11 2- 12'-6• (REFER TO UGHTBASE DETAIL ON SK-3 FOR i r?, , ADDITIONAL INFORMATION) t i i i �,J t, t t PROPOSED LOCATION 4f THE.NEW EJ WARD Q i lIt PROPOSE REMOTE FILLSOCAi1ON FUEL.MOEMENT SYSTEM PEDESTAL — #i' _C, _ _ !— � �t ( MOUNT MIALIUM INCNE$ -y-_ ELECTFBCA CONDUITS SWILL PENETRATE 36•EQUIPMENT � sits? 24'MIP®N11 G;j�i FROM TANK ) CONCRETE PAD UNDERNEATH PEDESTAL CLEARANCE O ® ® ® 0. o ?�- ? BOL ARDS 12*FROM EDGE OF lit;- . lila MR TANK PAD TO CENTER OF BOLLARD {�- _ .+, 3v EQUIPMENT (TYPiCAI AS SIKXWIPI ) CLEARANCE 5!-5* 0111 ONVR,m"SElZW,CES EQUIPMENT TO BE MOUNTED 36• BEHIND BOLLARDS --- .w a-71-17-- -- -----r------- . .�. 6-DIAMETER CONCRETE d• < °• <`' s is i t (�) ° fR[EQ.eBOUARDS. ._ d a. .'tilt ENYRONMENTA 7 l?' • '•< 0"3'-6.A_ E -• i• • ••- .. <. • O_ _-Zrtl?. y _ APPRDE T-4� !8" ,•ift� •`� -• O tiff- t't a •- .( ) - Cd`680Y L SIN(I.E HOSE-.DISPENSER -�-,tet t• (SER TO SK fOR'FURTHER OETNL 11p ORATE REFER TO SK=3 FOR . • t ( 7� SERVICES JC EUIIPMENT CIEAWWCE(tYPICAL) 48 i I I i. ° a ADDROO IC INFMMAt10N - - • 1T).8E 9KXtlNtEQ 9N.A RETRACTOR t ti i t- a •ELECTRI:CG'�i¢UITS PENETRATE.PAB t 100 TOSCA DRIVE Bad .• a BEkIND.ItNIT.AS SHOWN •i i? 11` �''�'�l..rl c 1 ••e P.O. BOX 119 1 ? t 24•p FAPoitxE I( t•. ,• t t Ii _•. - e • !. . -- O • - • .. tt?iL STOUCI'ITON,.AIA 1T2072 BEIIEEN TN6W d d• • . • d • • �t i t, TEL r ) 242 - 9818 -- - - ... . . .... .. .. ... ._ ilii,. i�'1 , �.� ANDK�SK 't!'i; ..•-•..d " .. . ... ."••- - - 'e` -'tIG1,. TEL 3 341 - 1777 lit ; • :.A " a•d .•: i•• • -.i• •.A :• . - - .,,Lti FAX .297 - 7963 - `tt :]2C2:]2C `?tiv_.,Jc�= ---�a=_d=•_-== --•'�----a ji;�� _ TITLE: tli t;t ?i m PROPOSED Ait t ` ,- �{OF TAW PPD MOTOR VEHICLE �FUELING STATION I:,Ir 3fi E r;t?i t+-N CLFARANCEfTOPIGV.) I I ?t , i — LAYOUT ----- ---- isQ i6• APPROXIiATELY2'-6. 2._1O• DRAWN: ��/+' sAr 24• P.F.R. OF AlAs� ' 12' MICHAEL q�yNATIONAM.GN_ : APPROVED: 'MC&DOMCE FRW EDGE E. OF TANK R EOLP"PAD TO ((( ROOK SCALE: AS NOTED THE MW OF All MINE PLAN VIEW 3 CIVIL ti PROJECT NO- 2osToo-o9 1 i 8 w t'-0'' No,30463 -.--... J6•EQUtPkEM CIFARATIE(TYPICN ) ' -- i8'LT A NICE BEi OID TAt6C ANA D1aYEM5ER •o'Q DRAWING NO. 12' 1141 �C'IST E NG t3,5 'ss,Q A F 5K-1 PROPOSED EQUIPMENT LAYOUT DETAIL MAY 24, 2006 L. y10440 r `'� ,.r.mi�;.��� a 1 �Uj» .0 e�'ri� t'r.�l„`, }.mow' 4'Esq �4 � �� A.. Nit Ld mensions an these Oow;" .setaedence aver sealed dtinemden. ng ie ismed n conpctfon witR t referenced blow.No other use �3 TIE HOOFx 012' ed enthout the eeprese written TOP 3 HOOPS O A of CVM Enaronmentd Services. 6-J5 vERTKXES AS SHgYk ng show not be Used for tonst- ion purposes unti approved by the 1 OIA s 36•LONG ANCHOR B�.TS lett rnmoger. TO 13E SUPPLIED BY LIGHT MANUFACTURER GMT HMIT PER MMAIFACTUREOL S SPEC'$ � \\ g� 4 I\\ TOP OF CONCRETE TANX PAD 24' • ii'�- \� \ ��, 1 ND. APP. REVISION DATE T777 _ .a 5-0' `` �- rr�y! -iii REVISIONS . PROJECT- i natiOnal rid r. • LOCATION: 1OmTURNPIKE RO�ROUTE 114 LIGHT BASE - .DETAIL A 1/4' 31•_0'': ISOMETRIC VIEW NOT TO SCALE EXISTING BUILDING Cm DmillON1FA0IL SERVICES 8'40*CONCRETE TANK PAD REINFORCEMENT'16 GRADE 60 12.•ON CENTER EACH WAY SUPPORTED,By 2*W BAR SUPPORTS SPACED NO MORE THAN 48'APART. CYN 12'CLEAMNCE AS SHOWN FROM FACE OF PAD TO CENTER OF BOLLARD TYPICAL OF ALL BDLURDS) r"`- -- SERVICES (REFER TO SK-1.PIAN VIEk) FOR FURTHER LAYOUT DN'OR1V1lT10N) ���ti`. 1`CHAMFER EDGE OD ENI PEFOETER F THE 100 TOSCA DRIVE 6'DMETER SOUM40 CONCRETE FILLED'STEEL PPE BOLLARD: / P.M eox 119 CROWN TOP.C EM1 PIPE, PRK AND PAINT.SUPPLY YELLOWJTANK EONPMEM PAO SrOUCNYON. MA 02072 PLASTIC BOLLARD SLEEVE ON ALL'BOLLARDS f `t TEL 800 242 - 5818 1 TEL 781 341 - 1777 f t FAX 781 297 - 7963 1 1 I F . Ti•4000/ CONCRETE DRIVE APRON REWORCEIM M 15 GRADE 60 f, li , DRAWING TRIS 12.ON CENTER EACH WAY SUPPORTED BY 21SBU SUPPORTS SPACED NO MORE.THAN 48'APART. <. P 1 // 1 P'i w �t�t CUR M DR1U. 1/2•DOWELS INTO EXISTING DRIVE APRON �' FUELING STATION ATION EVERY 24'O.C. PRIOR TO POURING NEW SECTION 3'-6`ABOVE` GRADE i i ` X CONCRETE DETAILS 8'MAX:REVEAL SPECIREO BY NATIONAL GRID EXISTItlG NEIM r t I i i PY R. ORAwLG: otnvE AaRoa oslvvE APRON, t :` I i 1 t - -i-4------ ._------- �--Y--- ---- ----- --- GkiECKEO: L__ _� 4�_ - -_ J. " ' •! ,�_'_ f't"I"F f-t-F l f .t-F f-1-F -- -� ----- ------ -- -- I•i..I •G t• I. I •I r•I. I t I. I I •I ytYi OF .1 APPROVED: LI I t �' ss NATlONALOit10 S-6'BELOW GRAM RAM ` a ,,' t''t t,' • I 1 dI !. _ 12' I a� �.I ��' MICHAEL q�y • I, t I• t t� I '• t I t l I� I oG SCALE: I I t I I I-I f 1•.I l f I I I t .•& E. AS NOTED ROOK PROJECT TNT. CIVIL ai 206100-09 1 1 t __ No. 30463 DRAWING N0 6' SECTION A-AA `��fsTE�`��`�� 5K-2 LTWJ ELEVATION VIEW 1°�A "G� I/4' =1•-� E: MAY 24,, 2QOG L I r rf � 1 4.ii� :..�-