Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Building Permit #613-13 - 120 WINDKIST FARM ROAD 3/20/2013
� NORTN q BUILDING PERMIT 3? a�`•��`D_'"'6'.6�OOL TOWN OF NORTH ANDOVER ° o APPLICATION FOR PLAN EXAMINATION " Permit NO: Date Received �RATIIO PpP``�� Date Issued: �SS�►cHus�s IMPORTANT: Applicant must complete all items on this page LOCATION 1911 Pr t PROPERTY OWNER mo Print MAP NO: J61 PARCEL: ZONING DISTRICT: Historic District yes no Machine Shop Village yes TYPE OF IMPROVEMENT PROPOSED USE Residential Non- Residential [(New Building X One family ❑Addition ❑Two or more family ❑ Industrial ❑Alteration No. of units: ❑ Commercial ❑ Repair, replacement ❑Assessory Bldg ❑ Others: ❑ Demolition ❑ Other )(Septic ❑Well ❑ Floodplain ❑Wetlands ❑ Watershed District Ll Water/Sewer n t r Od Identification Please Type or Print Clearly) OWNER: Name: rj Y �k ,I ,.,, Phone: Address: CONTRACTOR Name: Phone: IQ�t2z���a L� Kt�.� �•�ys.. U C' Address: Supervisor's Construction License: Exp. Date: CS &zz4l. Home Improvement License: Exp. Date: ARCHITECT/ENG IN EER. 14,4u",4 Phone: =8,14(.2—,5R22- Address: I78y(.25 22Address: cwbv, ,,41 MA Reg. No. Awq FEE SCHEDULE:BULDING PERMIT.-$12.00 PER$1000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PER S.F. Total Project Cost: $ Y 2 ,S, 61,90 FEE: $ � g0 Check No.: / 7-S7712 Receipt No.: � �,� ;2 NOTE: Persons contracting with registered contractors do not have access to the guaranty fund Signature of Agent/Owner Signature of contractor t f L_ TOWN OF NORTH ANDOVER APPLICATION FOR PLAN EXAMINATION y Permit NO: Date Received Date Issued: IMPORTANT: Applicant must complete all items on this page - i LOCATION - Print PROPERTY OWNER Print 100 Year Old Structure yes no MAP NO: PARCEL: ZONING DISTRICT: Historic District yes no Machine Shop Village yes no i TYPE OF IMPROVEMENT PROPOSED USE Residential Non- Residential ❑ New Building ❑ One family ❑Addition El Two or more family El Industrial ❑Alteration No. of units: ❑ Commercial ❑ Repair, replacement ❑Assessory Bldg ❑ Others: ❑ Demolition ❑ Other ❑ Septic ❑Well ❑ Floodplain ❑Wetlands ❑ Watershed District ❑Water/Sewer DESCRIPTION OF WORK TO BE PERFORMED: Identification Please Type or Print Clearly) OWNER: Name: Phone: ' Address: CONTRACTOR Name: Phone: Address: Supervisor's Construction License: Exp. Date: Home Improvement License: Exp. Date: ARCHITECT/ENGINEER Phone: Address: Reg. No. FEE SCHEDULE:BULDING PERMIT:$12.00 PER$1000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PER S.F. Total Project Cost: $ FEE: $ Check No.: Receipt No.: NOTE: Persons contracting with unregistered contractors do not have access to the guarantyfund 5 g--.au--e of Agent/Owner Signature of contractor Plans Submitted ❑ Plans Waived ❑ Certified Plot Plan ❑ Stamped Plans ❑ Plans Submitted ❑ Plans Waived ❑ Certified Plot Plan ❑ Stamped Plans ❑ TYPE OF SEWERAGE DISPOSAL I Public Sewer ❑ Tanning/Massage/Body Art ❑ Swimming Pools ❑ Well ❑ Tobacco Sales ❑ Food Packaging/Sales ❑ Private(septic tank, etc. ® Permanent Dumpster on Site ❑ THE FOLLOWING SECTIONS FOR OFFICE USE ONLY INTERDEPARTMENTAL SIGN OFF - U FORM DATE REJECTED D TE APPROVED PLANNING & DEVELOPMENT ❑ r' COMMENTS c� Pj �ONSEZAT'ION Reviewed on 1 s �inture do COMMENTS NO �_,> �a,.. Qb` HEALTH Reviewed on t Signature COMMENTS Zoning Board of Appeals: Variance, Petition No: Zoning Decision/receipt submitted yes Planning Board Decision: Comments Conservation Decision: Comments Water& Sewer Connection/Si natur & G Driveway Permit v -\,\IPW Town ]Engineer: Signature: Located 384 Osgood Street FIRE DEPARTMENT - Temp Dumpster on site yes no Located at 124 MainStreet Fire Departinerlt signature/date y COMMENTS Dimension Number of Stories: Total square feet of floor area, based on Exterior dimensions. Total land area, sq. ft.: ELECTRICAL: Movement of Meter location, mast or service drop requires approval of Electrical Inspector Yes No DANGER ZONE LITERATURE: Yes No MGL Chapter 166 Section 21A—F and G min.$100-$1000 fine NOTES and DATA— For department use C6 n �T MIJ Q Notified for pickup - Date I Doc.Building Permit Revised 2010 Building Department The following is a list of the required forms to be filled out for the appropriate permit to be obtained. Roofing, Siding, Interior Rehabilitation Permits ❑ Building Permit Application ❑ Workers Comp Affidavit ❑ Photo Copy Of H.I.C. And/Or C.S.L. Licenses ❑ Copy of Contract ❑ Floor Plan Or Proposed Interior Work ❑ Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit Addition Or Decks ❑ Building Permit Application ❑ Certified Surveyed Plot Plan ❑ Workers Comp Affidavit ❑ Photo Copy of H.I.C. And C.S.L. Licenses ❑ Copy Of Contract ❑ Floor/Crossection/Elevation Plan Of Proposed Work With Sprinkler Plan And Hydraulic Calculations (If Applicable) ❑ Mass check Energy Compliance Report (If Applicable) ❑ Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit New Construction (Single and Two Family) ❑ Building Permit Application ❑ Certified Proposed Plot Plan ❑ Photo of H.I.C. And C.S.L. Licenses ❑ Workers Comp Affidavit ❑ Two Sets of Building Plans (One To Be Returned) to Include Sprinkler Plan And Hydraulic Calculations (If Applicable) ❑ Copy of Contract ❑ Mass check Energy Compliance Report ❑ Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit In all cases if a variance or special permit was required the Town Clerks office must stamp the decision from the Board of Appeals that the appeal period is over. The applicant must then get this recorded at the Registry of Deeds. One copy and proof of recording must be subm;ated with the building application Doc: Doc.Bui?ding Permit Revised 2012 Location Id 0 /tel/ �/ �5 / l/`7 i C No. 61?—4,7 Date TOWN OF NORTH ANDOVER • ��*T�tLrr�z���` • • yam _ Certificate of Occupancy $ /00 Building/Frame Permit Fee Foundation Permit Fee $ � Other Permit Fee TOTAL d Check# 7 �2 26217 wilding Inspector NORTh Of �4, APPLICATION FOR CERTIFICATE OF OCCUPANCYANSPECTION 1A4r'a 613-13 '�*i� BUILDING PERMIT # SSAC t1U9E ADDRESS/LOCATION OF PROPERTY: 120 Wlndklst Farm Road Map 109 Parcel 55 Lot Number 10 SUBDIVISION: DATE REQUESTED FILED/READY FOR INSPECTION: 10-15-2013 CLOSING DATE ON PROPERTY: 10-25-2013 FIVE (5)DAYS NOTICE PRIOR TO CLOSING DATE IS REQUIRED ALL WORK AND SIGN-OFFS MUST BE COMPLETED WITHIN THIS TIME FRAME. A REINSPECTION FEE OF TWENTY DOLLARS ($20.00) WILL BE CHARGED IF THE STRUCTURE DOES NOT MEET ALL APPLICABLE CODES. APPLICANT SIGNATURE Permit Issued to:Angela Jennings Address: 2 Alcott Way North Andover ROUTING CONSERVATION PLANNING �/ /3 [ �l� C061 5,-IEc� 5;1,04 hct Ue DPW-WATER METER 1t 3 SEWER CONNECTION ❑ non L DPW MUST INDICATE THAT THE WATER METER HAS BEEN INSTALLED PRIOR TO SUBMITTAL OF THE OCCUPANCY/INSPECTION REQUEST DPW /�/.91,1L SIGNATURE File:Application for OC form revised Jan 2007 „ °,NORTH,M ti 'fl7-O4ne re•`49 SSMCHOSft CERTIFICATE OF USE & OCCUPANCY TOWN OF NORTH ANDOVER Building Permit Number 613-13 on 3/20/2013 Date: October 30, 2013 THIS CERTIFIES THAT THE BUILDING LOCATED ON 120 Windkist Farm Road MAY BE OCCUPIED AS a single family home IN ACCORDANCE WITH THE PROVISIONS OF THE MASSACHUSETTS STATE BUILDING CODE AND SUCH OTHER REGULATIONS AS MAY APPLY. Certificate Issued to: Christopher& Angela Jennings 120 Windkist Farm Road North Andover,MA 01845 Building Insp ctor Fee: PrePaid $100.00 Receipt: 26217 Check : 1752 r 'i V - F OORTH _ .� : :. .c . . ve' 'o41 . . No. 1�0_ lip Z _v ver, Mass, toc xrc x!wrc x 04Aregi C> S U PERMI-T T LD . Food/Kitchen Septic System THIS CERTIFIES THAT.... ....: : ..:o� ..��............................................................. BLIT DING INSPECTOR �®1 ou atio has permission to erect ........ buildings on ...� ... f....t t l..it l.. . '.:: r:.. ,T -: ,•\ "I �� .................. ...... .... ugh/ /i� �. ` "I"'_? r/l! tobe occupied as ...............................r �....s.r`: ... .: . �� ........................................................ Chimney provided that the person accepting this permit shall in every respect`conform to the terms of the application Final , ti on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection,Alteration and 1 Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR VIOLATION of the Zoning or Building Regulations Voids this Permit. Rough Final .4" / I._, jk, PERMIT EXPIRES IN 6 MONTHS ELECTRICAL INSPE UNLESS CONSTRUCTION PTARTS /} l6—/_ ............... .. C`�{/ ................................. final &Lq, /0 BUILDING INSPECTOR GAS INSPECTOR Occupancy Permit Required to Occupy Building Rough Display in a Conspicuous Place on the Premises - Do Not Remove Final 6, No Lathing or Dry Wall To Be Done FIRE DEPARTMEN Until Inspected and Approved by the Building Inspector. B er Street No. Smoke Det. SEE REVERSE SIDE i a M Y ENT r Y OR 1 H 17 lixlie�lm I ic�vt Drive 15�Water Street •�4 Suite 2 110 Box 2285 \�;4vl�a ATort,NIA 019iO Skowhepin,'MF(u976 , [PARTNERS&ASSOCUTES F6L ' OtCC � JGsldS1,111dtrd(,*Mpa?}v '/7S.•}62.5+22 V. 1.07.:1911.0400 f'oun,ird?(7D!! •n'r-tri•' 978.462.$$23 F. 207302.1020 FINAL AFFIDAVIT STATEMENT OF PROJECT COMPLETION Project Number: WPA#023-13 Project Title: _ Jennings Residence Project Location: 120 Windkist Farm Road, North Andover MA Scope of.Project: _ Residential new construction of a single-family wood frame structure Date of Final Inspection: July 31, 2013 In accordance with Section 116.0 of the Massachusetts State Building Code i, Ronald F. Bukoski Registration No. 32024 being a registered professional engineer have prepared or directly supervised the preparation of all design plans, computations and specifications concerning: Entire Project------------ Architectural Structural X Mechanical Electrical Fire Protection Other for the above named project. These plans, computations and specifications meet the applicable provisions of the Massachusetts State Building code, acceptable engineering practices, and applicable laws and ordinances for the proposed use and occupancy. I, or my qualified representative, have done the following: 1. Reviewed shop drawings, samples and other submittals of the contractor as required by the construction contract documents as submitted for building permit, and approved them for conformance to the design concept. 2. Reviewed and approved the quality control procedures for all code-required controlled materials. 3. Been present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of critical construction components requiring controlled materials or construction specified in the accepted engineering practice standards. I visited the site during the construction process, and/or sent other appropriately qualified design professionals, and determined to the extent possible that the work was done in accordance with the documents submitted with the building permit application, and the applicable provisions of the Massachusetts State Building Code. � �Jtk OF A,,gssO 0 RONALD F. �"� o SUKOSKI CIVIL Signed: N0.32024 o Date: -7/31/ 13 ��°ts rE�``,��' s`fO'NAL ENS Page 2 of 1 � i � ��'L�� tDt'�:':"bJ1ZL'�i�'LCIrC�•.����'v fi�C�/d/�CC:;iFCLC}2��:12� ,� ^'/ f t =J2� 7�J7L2G'ZG f/ �i�fiX2 VE�i�Z'LCc^S — (✓ C2• C� � lll2 U'G:12 �G`LC�i4�12CGG ,ilf fP-c (rev.1106) C.:�' u � / � �.� 96 �Ioq c�/LI, SP,,,Y, 9i��crfs_ 0/773 13.G.L. CHAPTER 11 3, ScC TIONS 26F 26F71/c City or Towm____ V;, ❑��a: -7 This Certifies that the property loczted /�2Kz r r�7-- _ � do has been equipped with approved smoke detectors, and carbon monoxide alarms and was found to be in compliance with Massachuset"t General Law, Chapter 143 Sections 26F, 26Fr2 end 527 CMR 31, et seq. InsoectionYTesting completed on: _ �?�/` _ By: . In_F�•ccr i Fee Paid: Head of Fre Department: �� �� Q• • i- !,tote:This certificate expires sixty (60) days after date of issue. sem'`SELLER'S;CaPY Enter construction cost for fee cal- ' North Andover Fee Calculation Construction Cost $ 4759000.00 m $ - $ 5,700.00 Plumbing Fee $ 712.50 Gas Fee 100 comm. $ 100.00 Electrical Fee $ 712.50 Total fees collected $ 7,225.00 120 Windkist Farm Road 613-13 on 3/20/2013 Single Family Home r NORTH . 1c . . ve- No. C, h - ver, Mass, A— COC NIC Nl WICK 9d A0'?4TIE S V BOARD OF HEALTH Food/Kitchen PERMIT Te LD Septic System THIS CERTIFIES THAT441V. ! ? . ..5............................................................. BUILDING INSPECTOR has permission to erect ... buildings on Q...�/...1.� �.1� 1. ... . . Foundation � Rough tobe occupied as ...........................U................��...�`.................. ......................................................... Chimney provided that the person accepting this permit shall in every respec conform to the terms of the application Final on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection,Alteration and Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR VIOLATION of the Zoning or Building Regulations Voids this Permit. Rough Final PERMIT EXPIRES IN 6 MONTHS ELECTRICAL INSPECTOR UNLESS CONSTRUCTION TARTS Rough Service ........... ..... . .... .. ................................. Final BUILDING INSPECTOR GAS INSPECTOR Occupancy Permit Required to Occupy Building Rough Display in a Conspicuous Place on the Premises — Do Not Remove Final No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. Burner Street No. Smoke Det. � SEE REVERSE SIDE Massachusetts- Department ail•Public SafetN Board (if Building Re-ulations anti Stantlaj'tl1 Construction Supervisor License License: CS 62246 WILLIAM J JENNINGS JR 64 HAVERHILL ST READING, MA 01867 Expiration: 6/25/2013 '(uhimi.�inucr Tr#: 16207 WORKERS COMPENSATION AND EMPLOYERS LIABILITY INSURANCE POLICY Liberty AR INFORMATION PAGE mutual.. Liberty Mutual Group 175 Berkeley street Boston,MA 02117 Issued by LM INSURANCE CORPORATION 27243 Policy Number WC5-31S-383055-012 Issuing Office 181 RENEWAL OF: WC2-31S-383055-011 Issue Date 12-13-12 Account Number 1-383055 Sub Account 0000 1. Insured and Mailing Address FEIN 522415383 WJJPLANI`TiG&CONSTRUCTION LLC RISK ID 287590 64 fIA�'E.RHILL STREET REA DL1 G,INIA 01867 Status 46 - LIMITED LIABILITY CO Other workplaces not shown above: SEE ITEM 4. PREMIUM-EXTENSION OF INFORMATION PAGE 2. Policy Period: The policy period is from 11-25-2012 to 11-25-2013 12:01 A.M. standard time at the Insured's mailing address. 3. Coverage A. Workers Compensation Insurance: Part One of the policy applies to the Workers Compensation Law of the states listed here: . MA B. Employers Liability Insurance: Part Two of the policy applies to work in each state listed in Item 3.A. The limits of our liability under Part Two are: Bodily Injury by Accident $ 1, 000,000 each accident Bodily Injury by Disease $ 1, 000, 000 policy limit Bodily Injury by Disease $ 1, 000,000 each employee C. Other States Insurance: Part Three of the policy applies to the states, if any, listed here: SEE END WC 20 03 06A D. This policy includes these endorsements and schedules: SEE EXTENSION OF INFORMATION PAGE 4. Premium: The premium for this policy will be determined by our Manuals of Rules, Classifications, Rates and Rating Plans. All information required below is subject to verification and change by audit. Code Premium Basis Total Rate per$100 Estimated Annual Class fications Number Estimated Annual Remuneration of Remuneration Premium See Extension of Information Page Minimum Premium $ (MA) Total Estimated Annual Premium $ Premium will be billed ANNUAL Producer 0004-017109 TRE MCGLAUGRLIN AGENCY 828 LYNN FELLS PARKWAY MELROSE MA 02176 Sales Representative 3000 Sales Office Name WESTON 01987 National Council on Compensation lnsurance,lnc. WC 00 00 01 A All Rights Reserved Ed. 07/01/2011 Insured Copy WJJPL-1 OP ID: BS CERTIFICATE OF LIABILITY INSURANCE °A `' 06°`""""' 03/06/13 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: if the certificate holder Is an ADDITIONAL INSURED,the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the berms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsemen s. PRODUCERCON781-665-2775 NAME McLaughlin Insurance Agency 828 Lynn Fells Parkway Fax:781-665-0295 �w Ate : Melrose,MA 02176 ADDRESS. John E.McLaughlin Jr. INSURER(S)AFFORDING COVERAGE NAIC d INSURERA:Westem World Insurance Co. INSURED WJJ Planning&Construction, INSURER B:Liberty Mutual Insurance Co. LLC Bill Jennings INSURER C: 64 Haverhill Street INSURER D: Reading,MA 01867 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE POLICY CY EXP LIMITS LTR POLICY NUMBER GENERALLIABILRV EACH OCCURRENCE $ 1,800,00 A X COMMERCIAL GENERAL LIABILITY NPPS015151 07112/12 07/12113 DAMAGE TO RENTU PREMISES a occurrence) >' 60,00 CLAIMS-MADE a OCCUR MED EXP(Any one parson) $ 5,0 PERSONAL 6 ADV INJURY S 1,000,00 GENERAL AGGREGATE $ 2,000,00 GENLAGGREGATE LIMITAPPLIESPER: PRODUCTS-CCMP/OPAGG f 1,000,00 POLICY X PRO- LOC $ AUTOMOBILE LIABILITYCOMBINED SINGLE LIMIT a accident ANY AUTO BODILY INJURY(Per person) E ALL OWNED SCHEDULED AUTOS AUTOS BODILY INJURY(Per amWeM) _ HIRED AUTOS NON-OWNED PROP RTY DAMAGE AUTOS (Per id i 3 UMBRELLA UAB OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DEO I I RETENTIONf $ WORKERS COMPENSATION WC STA TU- TH- AND EMPLOYERS'LIABILITY LEEL- B ANY PROPRIETOWPARTNER/EXECUTNE Y/N O BE ISSUED BY CARRIER 11/25112 11/25113 E.L.EACH ACCIDENT $ 1,000,00 OFFICER/MEMBER EXCLUDED? Q NIA (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ 1,000 00 K es,descr be under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POIICY LIMIT $ 1,000,00 DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES(Attach ACORD 101,Addtdonal Remarks Schedule,M more space Is required) Evidence of insurance CERTIFICATE HOLDER CANCELLATION JENNI-2 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Chris Jennings THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 120 Windkist Farm Road ACCORDANCE WITH THE POLICY PROVISIONS. Andover,MA 01810 AUTHORIZED REPRESMATJVE ©1988.2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010105) The ACORD name and logo are registered marks of ACORD The Commonwealth of Massachusetts Print Form Department of Industrial Accidents Office of Investigations I Congress Street, Suite 100 _ Boston, MA 02114-2017 www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Na1710(Business/Organization/Individual): WJJ Planning&Construction,LLC Address:64 Haverhill St City/State/Zip:Reading, MA 01867 Phone #:7819422728 Are you an employer? Check the appropriate box: Type of project(required): 1. ✓❑ I am a employer with 1 4. ❑ I am a general contractor and 1 6. 0 New construction employees(full and/or part-time).* have hired the sub-contractors 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have g, ❑ Demolition working for me in any capacity. employees and have workers' insurance.: 9. E] Building addition [No workers comp.comp. insurance p• required.] 5. ❑ We are a corporation and its 10.❑ Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.❑ Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs insurance required.]t c. 152, §1(4), and we have no employees. [No workers' 13.0 Other comp. insurance required.] *,Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. T Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. tContractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. if the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name:Liberty Mutual Policy#or Self-ins. Lic.#:WC5-31 S-383055-012 Expiration Date:11-25-2013 Job Site Address:120 Windkist Farm Rd City/State/Zip:No Andover, MA 01845 Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to $1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certi unger thep4s and enalties !Z ur that the in ormation provided above is true and correct. Sijznature:E[A)IDate:March 4,2013 Phone#.7819422728 Official use only. Do not write inn this area, to be completed by city or town official City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3. City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: CONSTRUCTION CONTRACT This Construction Contract (the "Contract') is made as of April 10, 2013 (the "Effective Date") by and between Christopher W & Angela M Jennings ("C&A") of 2 Alcott Way, North Andover, Massachusetts 01845,and WJJ Planning&Construction, LLC("WJJ")of 64 Haverhill St, Reading, Massachusetts 01867. WJJ desires to provide Construction services to C&A and C&A desire to obtain such services from WJJ. THEREFORE, in consideration of the mutual promises set forth below,the parties agree as follows: 1. DESCRIPTION OF SERVICES. Beginning on April 10, 2013, W11 will provide to C & A the services described in the attached Exhibit A(collectively,the"Services"). 2. SCOPE OF WORK. WJJ will provide all services, materials and labor for the construction of a two story center entrance colonial with attached 2 car garage at the property of C & A located at: 120 Windkist Farm Rd, North Andover, Massachusetts,01845 hereinafter referred to as("Worksite"). This includes building and construction materials, necessary labor and site security, and all required tools and machinery needed for completion of construction. WJJ is not only responsible for furnishing any building improvements related to construction of the structure, but not related to landscaping, grading, walkways, painting, sewer or water systems, steps, driveways, patios and aprons,etc., unless they are specifically agreed to in writing. 3. PLANS, SPECIFICATIONS AND CONSTRUCTION DOCUMENTS. C & A will make available to WJJ all plans, specifications, drawings, blueprints, and similar construction documents necessary for WJJ to provide the Services described herein. Any such materials shall remain the property of C & A. WJJ will promptly return all such materials to C&A upon completion of the Services. 4. COMPLIANCE WITH LAWS. WJJ shall provide the Services in a workmanlike manner, and in compliance with all applicable federal, state and local laws and regulations, including, but not limited to all provisions of the Fair Labor Standards Act, the Americans with Disabilities Act,and the Federal Family and Medical Leave Act. S.WORK SITE. C&A warrants that C&A owns the property herein described,free and clear of any liens and encumbrances. Prior to the start of construction, C & A shall provide an easily accessible building site, which meets all zoning requirements for the structure, and in which the boundaries of C & A's property will be clearly identified by stakes at all corners of the property. C & A shall maintain these stakes in proper position throughout construction. 6. Contract Amount- WJJ shall provide the services described herein to C&A for the fixed price of four hundred seventy five thousand dollars ($475,000.00) Page 1 of 5 i 7. Payment-C&A agree to reimburse WJJ on a monthly basis for work performed the preceding month. A requisition based on the cost the line item Cost breakdown (attached) will be submitted the 25th of the month,with the amount requisitioned for work done the previous 30 day period. If any invoice is not paid when due, interest will be added to and payable on all overdue amounts at 12 percent per year, or the maximum percentage allowed under applicable laws, whichever is less. C & A shall pay all costs of collection, including without limitation, reasonable attorney fees. In addition to any other right or remedy provided by law, if C&A fails to pay for the Services when due, WJJ has the option to treat such failure to pay as a maty -1I breach of this Contract, and may cancel this Contract and or seek legal remedies. 8. TERM. WJJ shall commence the work to be performed within 30 days of April 10, 2013 and shall complete the work on or before October 31, 2013,time being of the essence of this contract. 9. CHANGE ORDER. C & A may make changes to the scope of the work from time to time during the term of this Contract. However, any such change or modification shall only be made in a written "Change Order"which is signed and dated by both parties. Such Change Orders shall become part of this Contract. C & A agrees to pay any increase in the cost of the Construction work as a result of any written, dated and signed Change Order. In the event the cost of a Change Order is not known at the time a Change Order is executed, WJJ shall estimate the cost thereof and C&A shall pay the actual cost whether or not this cost is in excess of the estimated cost. 10. PERMITS. C& A shall obtain all necessary building permits. WJJ shall apply for and obtain any other necessary permits and licenses required by the local municipal/county government to do the work, the cost thereof shall be included as part of the Payment to WJJ under this Contract. 11. INSURANCE. WJJ shall maintain the following levels of insurance in companies licensed to do business in the Commonwealth of Massachusetts. $2,000,000.00 General Liability $ 1000,000.00 Products-Completed Operations $ 1,000,000.00 Personal and Advertising Injury $50,000.00 Fire Damage Limit $ 1,000.00 Medical Expense Workers Compensation insurance per statute C&A shall maintain property insurance and builders risk insurance for value of materials on the site and labor expended,as will adequately cover the project. 12. WORK PRODUCT OWNERSHIP. Any copyrightable works, ideas, discoveries, inventions, patents, products, or other information (collectively the"Work Product ) developed in whole or in part by WJJ in connection with the Services will be the exclusive property of WJJ. Upon request, C&A will execute all documents necessary to confirm or perfect the exclusive ownership of WJJ to the Work Product. Page 2 of 5 13. CONFIDENTIALITY. WJJ, and its employees, agents, or representatives will not at any time or in any manner, either directly or indirectly, use for the personal benefit of WJJ, or divulge, disclose, or communicate in any manner, any information that is proprietary to C & A. WJJ and its employees, agents, and representatives will protect such information and treat it as strictly confidential. This provision will continue to be effective after the termination of this Contract. Upon termination of this Contract, WJJ will return to C & A all records, notes, documentation and other items that were used, created,or controlled by WJJ during the term of this Contract. 14. WARRANTY. WJJ shall provide its services and meet its obligations under this Contract in a timely and workmanlike manner, using knowledge and recommendations for performing the services which meet generally acceptable standards in WJJ's community and region, and will provide a standard of care equal to, or superior to, care used by service providers similar to WJJ on similar projects. WJJ shall construct the structure in conformance with the plans, specifications, and any breakdown and binder receipt signed by WJJ and C&A. 15. FREE ACCESS TO WORKSITE. C& A will allow free access to work areas for workers and vehicles and will allow areas for the storage of materials and debris. Driveways will be kept clear for the movement of vehicles during work hours. WJJ will make reasonable efforts to protect driveways, lawns, shrubs,and other vegetation. WJJ also agrees to keep the Worksite clean and orderly and to remove all debris as needed during the hours of work in order to maintain work conditions which do not cause health or safety hazards. 16. UTILITIES. C & A shall provide and maintain water and electrical service, connect permanent electrical service, gas service or oil service, whichever is applicable, and tanks and lines to the building constructed under this Contract after an acceptable cover inspection has been completed, and prior to the installation of any inside wall cover. C & A shall permit WJJ to use, at no cost, any electrical power and water use necessary to carry out and complete the work. 17. INSPECTION. C & A shall have the right to inspect all work performed under this Contract. All work that needs to be inspected or tested and certified by an engineer as a condition of any government departments or other state agency, or inspected and certified by the local health officer, shall be done at each necessary stage of construction and before further construction can continue.All inspection and certification will be done at C&A's expense. 18. DEFAULT. The occurrence of any of the following shall constitute a material default under this Contract: a.The failure of C&A to make a required payment when due. b. The insolvency of either party or if either party shall, either voluntarily or involuntarily, become a debtor of or seek protection under Title 11 of the United States Bankruptcy Code, e. A lawsuit is brought on any claim, seizure, lien or levy for labor performed or materials used on or furnished to the project by either party, or there is a general assignment for the benefit of creditors, application or sale for or by any creditor or government agency brought against either party. d.The failure of C&A to make the building site available or the failure of WJJ to deliver the Services in the time and manner provided for in this Contract. Page 3 of 5 6 19. REMEDIES. In addition to any and all other rights a party may have available according to law of the State of Massachusetts, if a party defaults by failing to substantially perform any provision, term or condition of this Contract (including without limitation the failure to make a monetary payment when due), the other party may terminate the Contract by providing written notice to the defaulting party. This notice shall describe with sufficient detail the nature of the default. The party receiving said notice shall have 45 days from the effective date of said notice to secure the default(s). Unless waived by a party providing notice, the failure to cure the default(s) within such time period shall result in the automatic termination of this Contract. 20. FORCE MAJEURE. If performance of this Contract or any obligation under this Contract is prevented, restricted, or interfered with by causes beyond either party's reasonable control ("Force Majeure"), and if the party unable to carry out its obligations gives the other party prompt written notice of such event, then the obligations of the party invoking this provision shall be suspended to the extent necessary by such event. The term Force Majeure shall include, without limitation, acts of God, fire, explosion, vandalism, storm, casualty, illness, injury,general unavailability of materials or other similar occurrence, orders or acts of military or civil authority, or by national emergencies, insurrections, riots, or wars, or strikes, lock-outs, work stoppages, or supplier failures. The excused party shall use reasonable efforts under the circumstances to avoid or remove such causes of non-performance and shall proceed to perform with reasonable dispatch whenever such causes are removed or ceased. An act or omission shall be deemed within the reasonable control of a party if committed, omitted, or caused by such party,or its employees,officers,agents,or affiliates. 21. ARBITRATION. Any controversy or claim arising out of or relating to this Contract, or the breach thereof, shall be settled by arbitration administered by the American Arbitration Association in accordance with its Commercial Arbitration Rules [including the Optional Rules for Emergency Measures of Protection], and judgment on the award rendered by the arbitrator(s) may be entered in any court having jurisdiction thereof. During any arbitration proceedings related to this Contract, the parties shall continue to perform their respective obligations under this Contract. 22. ENTIRE CONTRACT.This Contract contains the entire Contract of the parties, and there are no other promises or conditions in any other contract whether oral or written concerning the subject matter of this Contract.This Contract supersedes any prior written or oral agreements between the parties. 23. SEVERABILITY. If any provision of this Contract will be held to be invalid or unenforceable for any reason, the remaining provisions will continue to be valid and enforceable. If a court finds that any provision of this Contract is invalid or unenforceable, but that by limiting such provision it would become valid and enforceable, then such provision will be deemed to be written, construed, and enforced as so limited. 24.AMENDMENT.This Contract may be modified or amended in writing, if the writing is assigned by the party obligated under the amendment. 25. GOVERNING LAW.This Contract shall be construed in accordance with, and governed by the laws of the State of Massachusetts, regardless of the choice of law provisions of Massachusetts or any other jurisdiction. Page 4 of 5 26. NOTICE.Any notice or communication required or permitted under this Contract shall be sufficiently given if delivered in person or by certified mail, return receipt requested, to the address set forth in the opening paragraph or to such other address as one party may have furnished to the other in writing. 27. WAIVER OF CONTRACTUAL RIGHT. The failure of either party to enforce any provision of this Contract shall not be construed as a waiver or limitation of that party's right to subsequently enforce and compel strict compliance with every provision of this Contract. 28. ASSIGNMENT. Neither party may assign or transfer this Contract without the prior written consent of the non-assigning party,which approval shall not be unreasonably withheld. Owner: By: 3031a o 13 Christopher W Jen ngs/a By�Io��AA ( �` y I0 I✓ Angela M Jennings Contractor: WJJ Planning&Construction, LLC Contractor' U ense:CS 62246 By: 1 3�/��3 Wil i m J Jenni Page 5 of 5 Jenninas Residence-120 Windkist Farm Road-North Andover,MA Outline page 1/2 Feb 22,2013 SITEWORK Earthwork- move and grade existing material to within 12"of finish grade conforming to the slopes, contours and elevations as shown on site plan. Excavation -Foundation, excavation and backfill for building foundation, excess material to be spread and lost on site to 12" below finish grade. Backfill of foundation to be with of site material. Garage Area-Excavate existing material down to native soils, replace excavated material with reprocessed material placed in layers and compacted. Approximate depth 9'-0" Driveway-2"bituminous asphalt place in two layers over reprocessed material or gravel base 8"thick Drains- Interior sub floor drain under slab, perimeter house drain and downspout drains Utilities- Electric, excavation and backfill for underground service, pipe and installation of pipe by electrical contractor Septic Tank- Furnish and install a 1500 gallon septic tank with concrete riser and Cl cover connect to house and existing leach field. U/G Propane tank-Excavation and sand backfill for underground propane tank and trenching to house for supply lines. Landscaping -see allowances CONCRETE Foundation- 10" poured reinforced concrete foundation walls and 12"x 3'-0"wide continuous footing with key to foundation wall. Concrete to be 3/4' stone 3000psi mix. All footings to be a minimum of 4'-0" below exterior finish grade. Perimeter 4"foundation drain with perforated pipe wrapped in filter fabric Exterior surfaces below grade to have damproofing applied including sealing of wall to footing Footing and pier at rear deck under all posts, minimum depth bottom footing 4'-0" below grade Slab-4"slab on grade over 8"of crushed stone. Garage floor to pitch toward doors FRAMING & Insulation Lumber-2+BTR KD Spruce, 2x6 exterior walls, 2x4 interior walls Structural -refer to plan for engineered wood sizes Sheathing - plywood Tyvek building wrap Sub Floor- 1 st floor, 2nd floor attic T& G plywood Insulation - Exterior Walls &Garage/house wall in accordance with Ma state energy code Roofing-Architectural GAF Timberline asphalt 30 year shingles or equal At all eaves, valleys, and roof line intersection install ice&water self sealing membrane Flashing Exterior siding and trim-Hardie Plank Lap Siding in standard ColorPlus color. Blind nailed and installed per manufacturers specifications. Azec trim components, refer p p o e t plan for type and location. Doors&Windows Main entry door-FG unit with sidelights Exterior doors-FG refer to plan for type Deck/Patio-sliders, refer to plan Windows-Andersen 400 series with screen and grills Interior doors-six panel solid core wood Interior Transoms-refer to plan for type and location Garage doors- Insulated sectional overhead door with glass and trim per plan, electrically operated. Shower Doors-glass in MBR, curtain and rod elsewhere Interior Trim&finish Casing 31/2" Baseboard -6" primed pine Cabinets&Vanities-master bedroom , 2nd floor bathroom, Wood Floors -prefinished hardwood Hard the-Floor of bathrooms, shower stall wall Countertop-stone or granite kitchen, bathrooms, laundry Main Stairs-hardwood stained treads, painted risers and skirt board Cellar Stairs&Attic -2x stringers with 3/4"plywood tread and riser WJJ Planning&Construction, LLC Reading MA 01867 T-781 942 2728 F-781 942 0039 E-wjjpcm@comcast.net i Jennings Residence - 120 Windkist Farm Road - North Andover, MA Outline page 2/2 Feb 22, 2013 Interior Trim&finish-continued Plaster-walls&ceilings, 1/2'gypsum board with thin coat veneer plaster, smooth finish Cement board-floors in bathrooms tub and shower wall Painting-Interior walls Interior Ceilings Door/Window trim&baseboard Plumbing-fixtures and layout per plan Water closets-per plan Sinks-bathroom, kitchen, Tub Shower Washer hook up Ice maker water piping Exterior hose bibs-anti freeze type Back flow preventer for U/G sprinklers All HW piping to be insulated Water heater gas fueled propane 50 gallon Heating&Air conditioning,Ventilation Fuel-propane gas Ducted warm air heating electric cooling HVAC-(two systems 1-first floor and future basement, 2-2nd floor future attic Hi efficiency variable speed Condensers pad mount Hi efficiency units Two stage condensers Programmable thermostats Energy recovery/ventilation system Electrical Service-underground 200 A, 30 breaker panel with adjacent GFI receptacle Built in lighting--recessed high hat, allow three in each- Fam Rm, breakfast, kitchen, Liv rm, din rm Wall Mounted&Overhead Lighting- Fixtures by homeowner, installation by electrical contractor,entry, Din Rm, Kit Island, MBR/Bath (5), BR 1 ea, Bathroom 1 ea Outside lighting-ground up lights on front of house, pole light at front walk,wall mild. at each exterior door Switches and outlets-White standard Outlets-standard layout per code Door bell-front side and rear door Telephone-pre wired jacks in bedrooms, kitchen,office,family room Garage Door Openers-receptacle for plug in, operator unit supplied by others Washer/dryer power-2nd floor Bathroom ventilation Heat&Smoke&Carbon monoxide sensors-as required by code Power for appliances-HVAC-(two systems 1-basement, 1-1st floor, 1-2nd floor, exterior pad mount condensers, HWH, Garbage disposal, refrigerator,dishwasher, microwave Audio system- Cable&Jack- in each bdrm,fam rm, LR, kitchen Exterior Camera at garage Alarm-Security System Wireless system Motion sensors exterior at all doors Door and Window sensors Automatic Fire Sprinklers Wet Type Automatic Whole House WJJ Planning&Construction,LLC Reading.MA 01867 T-7819422728 F-7819420039 E-wjjpcm@comeast.net REScheck Software Version 4.4.4 Compliance Certificate Project Title: Jennings Residence Energy Code: 2009 IECC Location: North Andover,Massachusetts Construction Type: Single Family Project Type: New Construction Orientation: Unspecified Conditioned Floor Area: 1,952 ft2 Glazing Area Percentage: 20% Heating Degree Days: 6322 Climate Zone: 5 Permit Date: Construction Site: Owner/Agent: Designer/Contractor: 120 Windkist Farm road Christopher Jennings Alan O'Connell North Andover,MA 120 Windkist Farm Road 39 Herrick Road North Andover,MA Peabody,MA 01960 978-979-8294 alanoconnell@comr,ast.net Comp]ia n ce:,Passes using UA trade-off Compliance: 7.0%Better Than Code Maximum UA: 441 Your UA:410 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Cavity Assembly . or Door UA Perimeter • Ceiling 1:Flat Ceiling or Scissor Truss 1,952 38.0 0.0 59 Wall 1:Wood Frame, 16"o.c. 593 21.0 0.0 20 Orientation:Unspecified Window 1:Wood Frame:Triple Pane with Low-E 225 0.310 70 SHGC:0.00 Orientation:Unspecified Door 1:Solid 21 0.500 11 Orientation:Unspecified Wall 2:Wood Frame,16"o.c. 568 21.0 0.0 29 Orientation:Unspecified Window 2:Wood Frame:Triple Pane with Low-E 68 0.310 21 SHGC:0.00 Orientation:Unspecified Wall 3:Wood Frame,16"o.c. 583 21.0 0.0 30 Orientation:Unspecified Window 3:Wood Frame:Triple Pane with Low-E 53 0.310 16 SHGC:0.00 Orientation:Unspecified Wall 4:Wood Frame, 16"o.c. 933 21.0 0.0 42 Orientation:Unspecified Window 4:Wood Frame:Triple Pane with Low-E 154 0.310 48 SHGC:0.00 Orientation:Unspecified Project Title: Jennings Residence Report date: 02/14/13 Data filename: C:\Documents and Settings\Trudy\My Documents\REScheck\Jennings Residence.rck Pagel of 8 Gross Glazing Assembly . . Door UA Perimeter 1.11-Factor Door 2:Glass 41 0.310 13 SHGC:0.00 Orientation:Unspecified Floor 1:All-Wood Joist/Truss:Over Unconditioned Space 1,952 38.0 0.0 51 Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2009 IECC requirements in REScheck Version 4.4.4 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. I Name-Title Signature Date Project Title: Jennings Residence Report date: 02/14/13 Data filename: C:\Documents and Settings\Trudy\My Documents\REScheck\Jennings Residence.rck Page 2 of 8 REScheck Software Version 4.4.4 i Inspection Checklist Requirements: 0.0% were addressed directly in the REScheck software Text in the"Comments/Assumptions"column is provided by the user in the REScheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided. 20091ECC Pre-Inspection/Plan Review Plans Verified Field Verified Complies? CommentslAssumptions Value Value 103.2 Construction drawings and ❑Complies [PR1]' documentation demonstrate energy ❑Does Not Comply code compliance for the building ❑Not Observable envelope. ❑Not Applicable 103.2, 'Construction drawings and ❑Complies 403.7 documentation demonstrate energy ❑Does Not Comply. [PR3)' code compliance for lighting and []Not Observable i mechanical systems.Systems serving ❑Not Applicable multiple dwelling units must demonstrate compliance with the commercial code. 403.6 Heating and cooling equipment is Heating: Heating: ❑Complies [PR2]2 sized per ACCA Manual S based on Btu/hr Btu/hr ❑Does Not Comply loads per ACCA Manual J or other Cooling: Cooling: ❑Not Observable approved methods. Btu/hr Btu/hr ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Jennings Residence Report date: 02/14/13 Data filename: C:\Documents and Settings\Trudy\My Documents\REScheck\Jennings Residence.rck Page 3 of 8 2009 IECC Foundation Inspection Complies? Comments/Assumptions 303.2.1 A protective covering is installed to ❑Complies [FO11]z protect exposed exterior insulation ❑Does Not Comply R and extends a minimum of 6 in.below ❑Not Observable grade. ❑Not Applicable 403.8 Snow-and ice-melting system ❑Complies [FO12]2 controls installed. ❑Does Not Comply: ❑Not Observable []Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Jennings Residence Report date: 02/14/13 Data filename: C:\Documents and Settings\Trudy\My Documents\REScheck\Jennings Residence.rck Page 4 of 8 20091ECC Framing/Rough-In Inspection Pla Value fied Field Value fied Complies? CommentslAssumptions 402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies table for 402.3.4 ❑Does Not Comply values. [FR1]' '❑Not Observable ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies table for 402.3.1, average). ❑Does Not Comply values. 402.3.3, ;❑Not Observable 402.5 ,❑Not Applicable [FR2]' 303.1.3 U-factors of fenestration products are ❑Complies [FR4]' determined in accordance with the ❑Does Not Comply NFRC test procedure or taken from I❑Not Observable lu 'the default table. ❑Not Applicable 402.3.5 Sunrooms enclosing conditioned U- U- ❑Complies [FR8]' space have a maximum fenestration ❑Does Not Comply U-factor of 0.50 in Climate Zones 4-8. ❑Not Observable 10 New glazing separating the sunroom ❑Not Applicable from conditioned space must meet code requirements. 402.3.5 Sunrooms enclosing conditioned U- U- ❑Complies [FR9]' space have a maximum skylight U- ❑Does Not Comply 19 factor of 0.75 in Climate Zones 4-8. [-]Not Observable [-]Not Applicable 402.4.4 Fenestration that is not site built is ❑Complies [FR20]' listed and labeled as meeting ❑Does Not Comply AAMAM/DMA/CSA 101/I.S.2/A440 or ❑Not Observable has infiltration rates per NFRC 400 ❑Not Applicable that do not exceed code limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish and ❑Does Not Comply labeled to indicate 2.0 cfm leakage at ❑Not Observable 75 Pa. ❑Not Applicable 403.2.1 Supply ducts in attics are insulated to R- R- ❑Complies [FR12]' 'R-8.All other ducts in unconditioned R- R- ❑Does Not Comply spaces or outside the building ❑Not Observable envelope are insulated to R-6. ❑Not Applicable 403.2.2 All joints and seams of air ducts,air ❑Complies [FR13]' handlers,filter boxes,and building ❑Does Not Comply cavities used as return ducts are ❑Not Observable sealed. ❑Nat Applicable 403.2.3 Building cavities are not used for ❑Complies [FR15]3 supply ducts. ❑Does Not Comply ❑Nat Observable ❑Not Applicable 403.3 HVAC piping conveying fluids above R- R- ❑Complies [FR17]2 105 IF or chilled fluids below 55 OF ❑Does Not Comply A are insulated to R-3. ❑Not Observable ,[:]Not Applicable 403.4 Circulating service hot water pipes are' R- R- ❑Complies [FR18]2 insulated to R-2. ❑Does Not Comply, ❑Not Observable ❑Not Applicable 403.5 Automatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air intakes and ❑Does Not Comply exhausts. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Jennings Residence Report date: 02/14/13 Data filename: C:\Documents and Settings\Trudy\My Documents\REScheck\Jennings Residence.rck Page 5 of 8 Plans Verified Field Verified 2009 IECC Insulation Inspection7 Value Value Complies? Comments/Assumptions 303.1 All installed insulation is labeled or the ❑Complies [IN13]2 installed R-values provided. ❑Does Not Comply ❑Not Observable ❑Not Applicable 402.1.1, Floor insulation R-value. R- R- I❑Complies See the Envelope Assemblies table for 402.2.5, E] Wood ❑ Wood ❑Does Not Comply values. 402.2.6 ❑ Steel ❑ Steel ❑Not Observable [IN1]' -]Not Applicable 303.2, Floor insulation installed per ❑Complies 402.2.6 manufacturer's instructions,and in ❑Does Not Comply' [IN2]' substantial contact with the underside I❑Not Observable of the subfloor. ❑Not Applicable 402.1.1, Wall insulation R-value.If this is a R- R- ❑Complies See the Envelope Assemblies table for 402.2.4, mass wall with at least'%of the wall ❑ Wood ❑ Wood ❑Does Not Comply values. 402.2.5 insulation on the wall exterior,the ❑ Mass ❑ Mass ❑Not Observable [IN3]' exterior insulation requirement ❑ Steel ❑ Steel ❑Not Applicable applies. 303.2 Wall insulation is installed per ❑Complies [IN4]' manufacturer's instructions. ❑Does Not Comply ❑Not Observable ❑Not Applicable 402.2.11 Sunroom wall insulation has a R- R- ❑Complies [IN8]' minimum R-value of R-13.New walls ❑Does Not Comply separating the sunroom from ❑Not Observable conditioned space must meet code ❑Not Applicable requirements. 303.2 Sunroom wall insulation installed per ❑Complies [IN9]' manufacturer's Instructions. ❑Does Not Comply ❑Not Observable ❑Not Applicable 402.2.11 Sunroom ceiling minimum insulation R- R- ❑Complies [IN10]' R-value of R-19 in Climate Zones 1-4, ❑Does Not Comply and R-24 in Climate Zones 5-8. ❑Not Observable ❑Not Applicable 303.2 Sunroom ceiling insulation is installed ❑Complies [IN11]' per manufacture's instructions. ❑Does Not Comply ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Jennings Residence Report date: 02/14/13 Data filename: C:\Documents and Settings\Trudy\My Documents\REScheck\Jennings Residence.rck Page 6 of 8 20091ECC Final Inspection Provisions Plans Verified Field Verified Complies? Comments/Assumptions Value Value 402.1.1, Ceiling insulation R-value.Where>R- R- R- ❑Complies See the Envelope Assemblies table for 402.2.1, 30 is required,R-30 can be used if ❑ Wood ❑ Wood ❑Does Not Comply values. 402.2.2 insulation is not compressed at eaves. ❑ Steel ❑ Steel '❑Not Observable [FI1]' R-30 may be used for 500 ft'or 20% ❑Not Applicable (whichever is less)where sufficient space is not available. 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions.Blown ❑Does Not Comply, [F12]1 insulation marked every 300 ft'. ❑Not Observable ❑Not Applicable 402.2.3 Attic access hatch and door insulation R- R- ❑Complies [FI3]' 'R-value of the adjacent assembly. ❑Does Not Comply 1 '❑Not Observable [-]Not Applicable 402.4.2, Building envelope tightness verified ACH 50= ACH 50= ❑Complies 402.4.2.1 by blower door test result of<7 ACH ❑Does Not Comply [Fl 17]1 at 50 Pa.This requirement may ❑Nat Observable 9 instead be met via visual inspection, ❑Not Applicable in which case verification may need to occur during Insulation Inspection. 402.4.3 Wood-buming fireplaces have ❑Complies [FI8]2 gasketed doors and outdoor lElDoes Not Comply �J combustion air. ❑Not Observable ❑Not Applicable 403.2.2 Post construction duct tightness test cfm cfm ❑Complies [FI4]' result of 8 cfm to outdoors,or 12 cfm ❑Does Not Comply across systems.Or,rough-in test ❑Not Observable result of 6 cfm across systems or 4 ❑Not Applicable cfm without air handler.Rough-in test verification may need to occur during Framing Inspection. 403.1.1 Programmable thermostats installed ❑Complies [F19]2 on forced air furnaces. ❑Does Not Comply y ❑Not Observable ❑Not Applicable 403.1.2 Heat pump thermostat installed on ❑Complies [F110]2 heat pumps. ❑Does Not Comply [-]Not Observable ❑Not Applicable 403.4 Circulating service hot water systems '❑Complies [FI11]2 have automatic or accessible manual ❑Does Not Comply controls. ❑Not Observable ❑Not Applicable 403.9.1 Readily accessible switch on heaters ❑Complies [FI 12]3 for swimming pools. ❑Does Not Comply ❑Not Observable ❑Not Applicable 403.9.2 Timer switches on pool heaters and ❑Complies [F119]3 pumps are present. ❑Does Not Comply. y []Not Observable []Not Applicable 403.9.3 Heated swimming pools have a cover. ❑Complies [F120]3 Covers on pools heated over 90 OF ❑Does Not Comply M_ are insulated to R-12. ❑Not Observable ❑Not Applicable 404.1 50%of lamps in permanent fixtures ❑Complies [FI6]' are high efficacy lamps. ❑Does Not Comply' ❑Not Observable ❑Not Applicable 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Jennings Residence Report date: 02/14/13 Data filename: C:\Documents and Settings\Trudy\My Documents\REScheck\Jennings Residence.rck Page 7 of 8 Y 20091ECC Final Inspection Provisions Plans Verified Field Verified Complies? Comments/Assumptions Value Value 401.3 Compliance certificate posted. ❑Complies [F[7]2 ❑Does Not Comply ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for mechanical ❑Complies [F118]3 and water heating equipment have ❑Does Not Comply 1. been provided. []Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Jennings Residence Report date: 02/14/13 Data filename: C:\Documents and Settings\Trudy\My Documents\REScheck\Jennings Residence.rck Page 8 of 8 r 2009 IECC Energy Efficiency Certificate Wall 21.00 Floor 38.00 Ceiling/Roof 38.00 Ductwork(unconditioned spaces): Window 0.31 Door 0.31 Heating System: Cooling System: Water Heater: Name: Date: Comments: 7�2, REScheck Software Version 4.4.4 Compliance Certificate Project Title: Jennings Residence Energy Code: 2009 IECC Location: North Andover,Massachusetts Construction Type: Single Family Project Type: New Construction Orientation: Unspecified Conditioned Floor Area: 1,952 ft2 Glazing Area Percentage: 20% Heating Degree Days: 6322 Climate Zone: 5 Permit Date: Construction Site: Owner/Agent: Designer/Contractor: 120 Windkist Farm road Christopher Jennings Alan O'Connell North Andover,MA 120 Windkist Farm Road 39 Herrick Road North Andover,MA Peabody,MA 01960 978-979-8294 alanoconnell@comcast.ne CO • Compliance: 7.0%Better Than Code Maximum UA: 441 Your UA:410 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-rode home. Envelope Assemblies AssemblyCavit• :R-Value R-VaWe or Door LIA Perimeter • Ceiling 1:Flat Ceiling or Scissor Truss 1,952 38.0 0.0 59 Wall 1:Wood Frame,16"D.C. 593 21.0 0.0 20 Orientation:Unspecified Window 1:Wood Frame:Triple Pane with Low-E 225 0.310 70 SHGC:0.00 Orientation:Unspecified Door 1:Solid 21 0.500 11 Orientation:Unspecified Wall 2:Wood Frame,16"o.c. 568 21.0 0.0 29 Orientation:Unspecified Window 2:Wood Frame:Triple Pane with Low-E 68 0.310 21 SHGC:0.00 Orientation:Unspecified Wall 3:Wood Frame,16"o.c. 583 21.0 0.0 30 Orientation:Unspecified Window 3:Wood Frame:Triple Pane with Low-E 53 0.310 16 SHGC:0.00 Orientation:Unspecified Wall 4:Wood Frame,16"D.C. 933 21.0 0.0 42 Orientation:Unspecified Window 4:Wood Frame:Triple Pane With Low-E 154 0.310 48 SHGC:0.00 Orientation:Unspecified Project Title: Jennings Residence Report date: 02/14/13 Data filename: C:\Documents and Settings\Trudy\My Documents\REScheck\Jennings Residence.rck Page 1 of 8 • li � • • • Assembly • or Door UA FactorPerimeter U Door 2:Glass 41 0.310 13 SHGC:0.00 Orientation:Unspecified Floor 1:All-Wood Joist/Truss:Over Unconditioned Space 1,952 38.0 0.0 51 Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and )ther calculations submitted with the permit application.The proposed building has been designed to meet the 2009 IECC requirements in RESci ieck Version 4.4.4 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name-Title % Signature ate I I Project Title: Jennings Residence Report date: 02/14/13 Data filename: C:\Documents and Settings\Trudy\My Documents\REScheck\Jennings Residence.rck Page 2 of 8 REScheck Software Version 4.4.4 Inspection Checklist o ' Requirements: 0.0% were addressed directly in the REScheck software Text in the"Comments/Assumptions"column is provided by the user in the REScheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided. 2009 IECC Pre-Inspection/Plan Review Pians Verified Field Verified Complies? mments/Assumptions Value Valu® 103.2 A Construction drawings and ❑Complies [PR1)1 documentation demonstrate energy ❑Does Not Comply code compliance for the building ❑Not Observable envelope. ❑Not Applicable 103.2, Construction drawings and ❑Complies 403.7 documentation demonstrate energy ❑Does Not Comply [PR31' code compliance for lighting and mechanical systems.Systems serving ❑Not Observable multiple dwelling units must []Not Applicable demonstrate compliance with the commercial code. _ 403.6 Heating and cooling equipment is Heating: Heating: ❑Complies [PR2]2 sized per ACCA Manual S based on Btu/hr Btu/hr ❑Does Not Comply loads per ACCA Manual J or other Cooling: Cooling: ❑Not Observable approved methods. Btu/hr Btu/hr ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) i Project Title: Jennings Residence Report date: 02/14/13 Data filename: C:\Documents and Settings\Trudy\My Documents\REScheck\Jennings Residence.rck Page 3 of 8 2009 IECC Foundation Inspection Complies? Comments/Assumptic ns 303.2.1 A protective covering is installed to ❑Complies [FO11)2 protect exposed exterior insulation ❑Does Not Comply and extends a minimum of 6 in.below ❑Not Observable grade. [-]Not Applicable 403.8 Snow-and ice-melting system ❑Complies Y� [FO12]2 controls installed. ❑Does Not Comply ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)~ Project Title: Jennings Residence Report date: 02/14/13 Data filename: C:\Documents and Settings\Trudy\My Documents\REScheck\Jennings Residence.rck Page 4 of 8 Plans Verified Field Verified 12009 IECC Framing I Rough-In Inspection Value Value Complies? Comments/Assumptions 402.1.1, Door U-factor. U- U- ❑Complies See the L nvelope Assemblies table for 402.3.4 ❑Does Not Comply values. [FR1]' ❑Not Observable 4 []Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- _❑Complies V See the L nvelope ie table for 402.3.1, average). ❑Does Not Comply values. 402.3.3, ❑Not Observable 402.5 ❑Not Applicable [FR2]' ra, 303.1.3 U-factors of fenestration products are v ❑Complies [FR4]' determined in accordance with the ❑Does Not Comply 4s, NFRC test procedure or taken from ❑Not Observable the default table. ❑Not Applicable _ 402.3.5 Sunrooms enclosing conditioned U- U- ❑Complies i[FR8]' space have a maximum fenestration ❑Does Not Comply h, U-factor of 0.50 in Climate Zones 4-8. ❑Not Observable New glazing separating the sunroom from conditioned space must meet ❑Not Applicable code requirements. 402.3.5 Sunrooms enclosing conditioned _ U- _ U- ~� ❑Complies [FR9]' space have a maximum skylight U- ❑Does Not Comply �* factor of 0.75 in Climate Zones 4-8. ❑Not Observable ❑Not Applicable 402.4.4 Fenestration that is not site built is� ❑Complies [FR20]' listed and labeled as meeting ❑Does Not Comply AAMAIWDMA/CSA 101II.S.2IA440 or ❑Not Observable has infiltration rates per NFRC 400 that do not exceed code limits. ❑Not Applicable 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housingfinterior finish and ❑Does Not Comply labeled to indicate 2.0 cfm leakage at ❑Not Observable 75 Pa. ❑_Not Applicable _ 403.2.1 Supply ducts in attics are insulated to R- R- ❑Complies [FR12]' R-8.All other ducts in unconditioned R- R- ❑Does Not Comply spaces or outside the building ❑Not Observable envelope are insulated to R-6. ❑Not Applicable 403.2.2 All joints and seams of air ducts,air ❑Complies [FR13]' handlers,filter boxes,and building ❑Does Not Comply cavities used as return ducts are ❑Not Observable sealed. ❑Not Applicable 403.2.3 Building cavities are not used for ❑Complies [FR15]3 supply ducts. ❑Does Not Comply t ❑Not Observable []Not Applicable 403.3 HVAC piping conveying fluids above R- R- ❑Complies [FR17]2 105 OF or chilled fluids below 55 OF ❑Does Not Comply uj are insulated to R-3. ❑Not Observable ❑Not Applicable 403.4 Circulating service hot water pipes are R- R- ❑Complies [FR18]2 insulated to R-2. ❑Does Not Comply 13 ❑Not Observable _❑Not Applicable 403.5 Automatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air intakes and ❑Does Not Comply exhausts. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: `1 High Impact(Tier 1) 2 Medium Impact(Tier 2) —�3 ILow Impact(Tier 3) Project Title: Jennings Residence Report date: 02/14/13 Data filename: C:\Documents and Settings\Trudy\My Documents\REScheck\Jennings Residence.rck Page 5 of 8 20091ECC Insulation Inspection Pia sleeiefied FielValuefed Compiles? C mmentslAssumptions 303.1 All installed insulation is labeled or the ❑Complies [IN13]2 installed R-values provided. ❑Does Not Comply ❑Not Observable []Not Applicable 402.1.1, Floor insulation R-value. R- R- ❑Complies See the table for 402.2.5, ❑ Wood ❑ Wood ❑Does Not Comply values. 402.2.6 ❑ Steel ❑ Steel ❑Not Observable [IN1]' ❑Not Applicable 303.2, Floor insulation installed per []Complies 402.2.6 manufacturer's instructions,and in ❑Does Not Comply [IN2]' substantial contact with the underside ❑Not Observable 4-A of the subfloor. ❑Not Applicable 402.1.1, Wall insulation R-value.If this is a R- R- ❑Complies See the table for 402.2.4, mass wall with at least Y2 of the wall [:] Wood ❑ Wood []Does Not Comply values. 402.2.5 insulation on the wall exterior,the ❑ Mass ❑ Mass ❑Not Observable [IN3]' exterior insulation requirement ❑ Steel ❑ Steel ❑Not Applicable applies. 303.2 Wall insulation is installed per ❑Complies [iN4]' manufacturer's instructions. []Does Not Comply ❑Not Observable _ []Not Applicable 402.2.11 Sunroom wall insulation has a _ R- R- ❑Complies [IN8]' minimum R-value of R-13.New walls ❑Does Not Comply t� separating the sunroom from ❑Not Observable conditioned space must meet code ❑Not Applicable requirements. 303.2Sunroom wall insulation installed per ❑Complies [IN9]' manufacturer's Instructions. ❑Does Not Comply ❑Not Observable _❑Not Applicable 402.2.11 Sunroom ceiling minimum insulation R- R- ❑Complies [IN10]' R-value of R-19 in Climate Zones 1-4, ❑Does Not Comply tf and R-24 in Climate Zones 5-8. ❑Not Observable ❑Not Applicable 303.2 Sunroom ceiling insulation is installed ❑Complies [IN11]' per manufacturer's instructions. ❑Does Not Comply ❑Not Observable []Not Applicable Additional Comments/Assumptions: L 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) _ 3 Low Impact(Tier 3) Project Title: Jennings Residence Report date: 02/14/13 Data filename: C:\Documents and Settings\Trudy\My Documents\REScheck\Jennings Residence.rck Page 6 of 8 Plans Verified Field Verified 2009 IECC Final Inspection Provisions Value Value Complies? omments/Assumptions 402.1.1, Ceiling insulation R-value.Where>R- R- R- ❑Complies See the velope Assemblies table for 402.2.1, 30 is required,R-30 can be used if Wood ❑ Wood ❑Does Not Comply values. 402.2.2 insulation is not compressed at eaves. E] Steel El Steel ❑Not Observable [Fl1]' R-30 may be used for 500 ft2 or 20% y. (whichever is less)where sufficient []Not Applicable space is not available. 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions.Blown ❑Does Not Comply [FI2]' insulation marked every 300 ft2. ❑Not Observable ❑Not Applicable 402.2.3 Attic access hatch and door insulation R- R- ❑Complies [F13]1 R-value of the adjacent assembly. ❑Does Not Comply kf ❑Not Observable []Not Applicable _ 402.4.2, Building envelope tightness verified ACH 50= ACH 50= ❑Complies 402.4.2.1 by blower door test result of<7 ACH ❑Does Not Comply [F117]1 at 50 Pa.This requirement may ❑Not Observable it instead be met via visual inspection, in which case verification may need to []Not Applicable occur during Insulation Inspection. 402.4.3 Wood-burning fireplaces have ❑Complies [F[8]2 gasketed doors and outdoor ❑Does Not Comply �+ combustion air. ❑Not Observable ❑Not Applicable 403.2.2 Post construction duct tightness test cfm cfm ❑Complies [FI4)1 result of 8 cfm to outdoors,or 12 cfm ❑Does Not Comply ,t across systems.Or,rough-in test result of 6 cfm across systems or 4 ❑Not Observable cfm without air handler.Rough-in test ❑Not Applicable verification may need to occur during Framing Inspection. 403.1.1 Programmable thermostats installed ❑Complies [FI9F on forced air furnaces. []Does Not Comply r, ❑Not Observable ❑Not Applicable 403.1.2 Heat pump thermostat installed on ❑Complies u [Fl 10]2 heat pumps. ❑Does Not Comply ❑Not Observable _❑Not Applicable 403.4 Circulating service hot water systems ❑Complies [Fl 1112 have automatic or accessible manual ❑Does Not Comply t�. controls. ❑Not Observable ❑Not Applicable 403.9.1 Readily accessible switch on heaters ❑Complies [FI12]3 for swimming pools. ❑Does Not Comply V ❑Not Observable ❑Not Applicable 403.9.2 Timer switches on pool heaters and ❑Complies [Fl 19]3 pumps are present. ❑Does Not Comply s, ❑Not Observable ❑Not Applicable 403.9.3 Heated swimming pools have a cover. ❑Complies [F120]3 Covers on pools heated over 90 OF ❑Does Not Comply ., are insulated to R-12. ❑Not Observable ❑Not Applicable _ 404.1 50%of lamps in permanent fixtures ❑Complies [FI6]' are high efficacy lamps. ❑Does Not Comply t� ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) �r 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Jennings Residence Report date: 02/14/13 Data filename: C:\Documents and Settings\Trudy\My Documents\REScheck\Jennings Residence.rck Page 7 of 8 20091ECC Final Inspection Provisions Plans Verified Field Verified p Value Value Complies omments/Assumptions 401.3 Compliance certificate posted. []Complies [FI7]2 []Does Not Comply A Not Observable ❑Not Applicable 303.3 Manufacturer manuals for mechanical ❑Complies ~� [FI 1813 and water heating equipment have ❑Does Not Comply been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: T[_High Impact(Tier 1)+�Medium Impact(Tier 2) 3 Low Impact(Tier 3) �� Project Title: Jennings Residence Report date: 02/14/13 Data filename: C:\Documents and Settings\Trudy\My Documents\REScheck\Jennings Residence.rck Page 8 of 8 09 IECC Energy Efficiency Certificate Wall 21.00 + Floor 38.00 Ceiling!Roof 38.00 Ductwork(unconditioned spaces/): Window 0.31 Door 0.31 Heating System: Cooling System: Water Heater: Name: Date• Comments: C j f 66'-0° 17 . . , 54 � i d 1(1 *-17 o A O 1 ... —J • • _- CD • �1 E 1 4 1 11 3-4 `oI ^ 1 1 1-9 1 1 1 1 --- 3-7 3-10 2-,}-• 2-0 8-11 7-3 3-7 4-2 ! 'a k6 W. 4-6 r t.G ' • ^• O7 ^• 3n3 ,2 y_ _ 256 1 3-6 CD • i ! I _ I 256 1 i I I I I 38'-0" 28'-0° f 38'-0" - T 28'-C' FIRST FLOOR PLAN SECOND FLOOR PLAN T 66'-0" GENERAL NOTES r ELECTRIC BELL POTTER FLOW SWITCH r MODMENK1e11 —ALL CONCEALED PIPING TO"BLAZEMASTER" CPVC WITH CPVC FITTINGS. 1 / PIPE CLIP —ALL EXPOSED PIPING TO BE SCHEDULE 40 1"DRAIN 12-9 7-0 s a � STEEL WITH CAST IRON SCREWED FITINGS. 0 TO SYSTEM —ALL PIPE TO BE 1"(EXCEPT 1112"RISER) Cw _ This is _ 1 1 10 1 1 ! O PRESSURE GAGE HgNGER APPLICATION designed dlsprinkler protected by by a hydraulically 0 6-10 5-2 ® " 5-0 I ' -/ RESTRAI;ER APPLICATION Design Area No. 1 I ` � 1-i0 � Location:2ND FLR. t / Number of sprinklers calculated:2 CPVC PIPE • Basis of design: !� HEX HEAD SELF - - 1 ( TAPPING SCREW N.F.P.A. 13D I 1114"FEBCO 850 BACKFLOW 2 Density: RES. gpm/ft 5 o slo 5-0 Area: 495 Ft2 ' :SIPIGLE FASTENER Flow: 26.1 gpm® 45.2 psi 1 CPVC PIPE STRAP 8-8 10-4 5-2 _ 0 - - -- -- - -- - - Includes 0 gpm Hose allowance a i RISER DETAIL HANGER DETAIL 28'-0" NTS NTS BASEMENT PLAN N NOTES RMIONS SPRDWER SYNHOIS FIRE PROTECTION Wc Informwa macawTMx er s1u c T PosT ON FlNISH P K PT 9N a. MaDE �--- � RESIDENTAL SPRINKLER CO. NHnE 155 4.90 +/2" TY223.TYCO LFII Jennings Residence `" O _�^ ap �,� w r'niPO00 4 I 9DE ROME 155 4.20 i/2" W1334 NCO LFlI 23 PAGE ROAD. PDarr No. }� E aD.cm .. sar".D"aao.000 3 SIDE HRONE 155 S.fiO ," TY3355 TYCO DS-1 120 �FindL�st Farm Road s60 ,/2• TY3133 rrco TY_M LONDONDERRY, NH 03053 North Andover, MA �w N.Me"�r rn g mY GwUe" C-0' PH: 603-421-9692 � 3/16':tBY Aa' D.eum Vd a I6' 16 �►+„ ,,,p„o � FAX 603-421-9582 Dare 6-11-13 2' 4' 6' 8' 10 12' CONTRACTOR Owner FP 1 of 1 �s is Cl- �2- ZC;