HomeMy WebLinkAboutBuilding Permit #562-15 - 127 Campion Road 12/17/2014 10 R T►-� BUILDING PERMIT OFSpAOR ,° q1. TOWN OF NORTH ANDOVER 02 yam''` *° APPLICATION FOR PLAN EXAMINATION n Permit No#: Date Received R,1— �SSACHU`��� Date Issued: I ORTANT: Applicant must complete all items on this page ILOCATION oG `PROPE!RTY'OWNER 3 'u - eP,�nr Ce t 5 �-L rPrmt 100 Yearstrueture yes k® # MAP -Z- PARCELZONING'®ISTR:ICT�bHistoncrDist�ict yes qfr� � . . - FMMacfiN&ShopV--illage ye s. - � TYPE OF IMPROVEMENT PROPOSED USE Residential Non- Residential ❑ New Building ❑ One family ❑Addition ❑Two or more family ❑ Industrial ❑Alteration No. of units: ❑ Commercial ❑ Repair, replacement ❑Assessory Bldg ❑ Others: ❑ Demolition ❑ Other Septic Well ,_❑tFloodplain Wetlands � ❑ 1Natershed�D stnct.- s - ❑°Wates/Sewer° DES RIPTION OF WORK T E PE FORMED: . i e Identification- Please Type or Print Clearly OWNER: Name: :.y,a'iV to S � S`" Gjet 5 Phone: Address: C:ontracto �iS �v x i _ n 7-T ter Fel t t Supervisor s�Construe"tlon,CLcense s - rHome Irr JroveffieAifl ce seR ARCHITECT/ENGINEER ^. ��.1 Phone: tr2v I r Address: S A t ��'. L�� l�.'�?, J s •tii Reg. No.--339 2 Lf FEE SCHEDULE.,BULDING PERMIT.$92.00 PER$1000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PER S.F. Total Project Cost: $ ; O t �s���y FEE: $ 7 , � � Check No.: Q0 Receipt No.: NOTE: Persons co tracting with unregistered contractors do not have access to the guaranty fund Si'nature ofA ent/Owner =.B` r Signature�of cortracto '��,� x_9 9_ - -- -- - ------ ....:----------_----- - - - - . - . .. . ... . . . . . . . . . . :. .I . i / Q Location{�� (C!M ay d J7 l No. Date�� � � . . . . . ; .: .. . I .. I-.-- I..- -, � .. I.. ...I.. . .: � . . � . .: .I . .. , . I .. . . ..-I-1-1. . � - ...- I. .. . . ,�. . .. � ��. ...:, � 11 ... ......� .� .. . I. .". .: .::� ::-1..�.::::..,:.�."....,. i� . � :::-1.. . ' '. .. --. . .. 1. . I .. ... .. ...., - - , i:: � .. I - . 1 . � :.�.:.: :.::;:� :: � .. ... . . : : . .1 . � 1. . 4 -i .. .j . ....� . . -�, . i�.. ....I I - :.�.1. ::,::��....-... . . . . .� . ... .. .. ...1. I... .� - .1 - :1-:1. ,.I. . . . . .......� -.... . .. • .. • TOWN OF NORTH ANDOVER . . ° s�z�rrMTvis ° . - -, `�° i . 1. �;_ Certificate of Occupancy $too I . ,.y ._ Building/Frame Permit Fee $ V T .. Foundation Permit Fee $ N��^ a �`'' Other Permit Fee $ TOTAL $ '../.,[� ;. (. I. r�T 1. l Check# / .._ ti , ; `."le -- I Building Inspector .. :. ._.. - r , ; . .. . f Plans Submitted Plans Waived ❑ Certified Plot Plan U� Stamped Plans TYPE OF SEWERAGE DISPOSAL Public Sewer ❑`� Tanning/Massage/Body Art ❑ Swimming Pools ❑ Well ❑ Tobacco Sales ❑ Food Packaging/Sales ❑ Private(septic tank,etc. ❑ Permanent Dumpster on Site ❑ THE FOLLOWING SECTIONS FOR OFFICE USE ONLY INTERDEPARTMENTAL SIGN OFF - U FORM PLANNING & DEVELOPMENT Reviewed On Signature_ COMMENTS CONSERVATION Reviewed on I Si nature I COMMENTS HEALTH Reviewed on Siqnature COMMENTS Zoning Board of Appeals: Variance, Petition No: Zoning Decision/receipt submitted yes Planning Board Decision: Comments Conservation Decision: Comments Water & Sewer Connection/Signature& Date Driveway Permit DPW Town Engineer: Signature: Located 384 Osgood Street FIRE _E ARTMENTTempDurnpsteno_ n—4't eyes _ ' nou `!LocatedRat24 'zzFire�Departmentsign""afore/date _ q ,I Dimension Number of Stories: Total square feet of floor area, based on Exterior dimensions. Total land area, sq. ft.: ELECTRICAL: Movement of Meter location, mast or service drop requires approval of Electrical Inspector Yes No DANGER ZONE LITERATURE: Yes No MGL Chapter 166 Section 21A—F and G min.$100-$1000 fine NOTES and DATA — (For department use) ❑ Notified for pickup Call Email f Date Time Contact Name Doe.Building Permit Revised 2014 IN Building Department ' The following is a list of the required forms to be filled out for the appropriate permit to be obtained. j. i Roofing, Siding, Interior Rehabilitation Permits c i i ❑ Building Permit Application ❑ Workers Comp Affidavit ❑ Photo Copy Of H.I.C. And/Or C.S.L. Licenses ❑ Copy of Contract ❑ Floor Plan Or Proposed Interior Work ❑ Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit Addition Or Decks i ❑ Building Permit Application ❑ Certified Surveyed Plot Plan ❑ Workers Comp Affidavit ❑ Photo Copy of H.I.C. And C.S.L. Licenses ❑ Copy Of Contract ❑ Floor/Cross Section/Elevation Plan Of Proposed Work With Sprinkler Plan And Hydraulic Calculations (If Applicable) ❑ Mass check Energy Compliance Report (If Applicable) ❑ Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit New Construction (Single and Two Family) ❑ Building Permit Application ❑ Certified Proposed Plot Plan ❑ Photo of H.I.C. And C.S.L. Licenses ❑ Workers Comp Affidavit ❑ Two Sets of Building Plans (One To Be Returned) to Include Sprinkler Plan And Hydraulic Calculations (if Applicable) ❑ Copy of Contract - ❑ Mass check Energy Compliance Report ❑ Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg. Permit Iyj all cases if a variance or special permit was required the Town Clerks office must stamp the decision from the Board of Appeals that the appeal period is over. The applicant must then get this recorded at the Registry of Deeds. One copy and proof of recording crust be submitted with the building application Doc:Building Permit Revised 2014 II � E NOR7M q ��ssncRuse��r CERTIFICA'T'E OF USE & OCCUPANCY TOWN OF NORTH ANDOVER Building Permit Number 562-2015 ON 12/17/2014 Date: May 16, 2016 THIS CERTIFIES THAT THE BUILDING LOCATED at 107 Campion Road MAY BE OCCUPIED AS a single family home IN ACCORDANCE WITH THE PROVISIONS OF THE MASSACHUSETTS STATE BUILDING CODE AND SUCH OTHER REGULATIONS AS MAY APPLY. Certificate Issued to: Glenn Saba 107 Campion Road - North Andover,MA 01845 Building Inspector Fee: PrePaid $100.00 Receipt: 28368 Check : 2041 40RT" own of 2 s _ : (, ndover No. Z s o h over, Mass, 1 171-1 1 A cocH(cntw(c" S U BOARD OF HEALTH RMIT T LDF /Kitche S is S em' s 7 P E BU DIN PEC�OR _ THIS CERTIFIES THAT0J).�:�.: .:....... ................................... � oundation has permission to erect buildings on .... .... ..•••••••••••••• �--�'� �7r RRou to be occupied as ...( ... ... ...�. ..�.�! :f..... :. . ..{. .4 ............. .. . .. ...... .. ...... Chi provided that the person accepting`tis permit shall in every respect conform to the'terms of the applica Ion nal on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection,Alteration and Construction of Buildings in the Town of North Andover. P MBING NSPECTOR�j Roue) .Jr1%li� VIOLATION of the Zoning or Building Regulations Voids this Permit. PERMIT EXPIRES IN 6 MONTHS ELECTRICAL INSPECTOR UNLESS CONSTRUCTIO STA TSRou �� �' ' s ................. .. ............. ................................ 'Fina-11 BUILDING INSPECTOR GAS INSPECTOR Occupancy Permit Required to Occupy Building Rough Display in a Conspicuous Place on the Premises — Do Not Remove Final d No Lathing or Dry Wall To Be Done FIRE DEPARTIVb NT Until Inspected and Approved by the Building Inspector. Burner Street No. 2r -" Smoke Det_1 11 f "i„ : ve 6 t; of ' r �G O * ND E _ APPLICATION FOR CERTIFICATE OF OCCUPANCYANSPEcCTION RTev BUILDING PERMIT# SAC104 ADDRES S&O CATION OF PROPERTY: 1 O -7 e c Map--j6 Z Parcel Lot Number SUBDIVISION: DATE REQUESTED FILED/READY FOR INSPECTION: CLOSING DATE ON PROPERTY: FIVE(5)DAYS NOTICE PRIOR TO CLOSING DATE IS REOUIRED ALL WORD AND SIGN-OFFS MUST BE COMPLETED WITHIN THIS TIME FRAME. A REINSPECTION FEE OF TWENTY DOLLARS ($20.00)WILL BE CHARGED IF THE-STRUCTURE DOES NOT MEET ALL APPLICABLE CODES. APPLICANT SIGNATURE Permit Issued to: f Address: (bi ROUTING TOWNENGINEER, SI-fEPL4N-1fU7WAYREVIEWr1 CONSERVATION PLANNING Qe,< c � �5)ZQ oLi Q� DPW-WATER METER Lel ,to ^ 1,r/ SEWER CONNECTION z� DPW MUST INDICATE THAT THE WATER METER HAS BEEN INSTALLED PRIOR TO SUBMITTAL OF THE OCCUPANCY/INSPECTION REQUEST DPW SIGNATURE Tile:Application for OC form revised Jan 2007/2011 °t;,`o DT NqH � r 3,SSAC N�sE•+, CERTIFICATE OF USE & OCCUPANCY TOWN OF NORTH ANDOVER Building Permit Number 562-2015 ON 12/17/2014 Date: May 16, 2016 THIS CERTIFIES THAT THE BUILDING LOCATED at 107 Campion Road MAY BE OCCUPIED AS a single family home IN ACCORDANCE WITH THE PROVISIONS OF THE MASSACHUSETTS STATE BUILDING CODE AND SUCH OTHER REGULATIONS AS MAY APPLY. Certificate Issued to: Glenn Saba 107 Campion Road North Andover,MA 0.1845 Building Inspector Fee. P $ • rePaid $100-00 Receipt: 28368 Check': 2041 nome Energy Rating Certificate � f Property HERS Century Builders Rating Type: Confirmed Certified Energy Rater: Jang Yoon AO 107 Campion Road Rating Date: 10/24/2015 Rating Number: SEA2402C North Andover, MA 01845 Registry ID: 985353272 Estimated Annual Energy Cost Use MMBtu Cost Percent HERS Index: 53 Efficient Home Comparison: 47% Better Heating 61.8 $3611 55% General Information Cooling 8.8 $202 3% Conditioned Area 4362 sq. ft. House Type Single-family detached Hot Water 8.7 $653 10% Conditioned Volume 42289 cubic ft. Foundation Unconditioned basement Lights/Appliances 32.9 $2149 32% Bedrooms 4 Photovoltaics -0.0 $.0 -0% Service Charges $0 0% Mechanical Systems Features Total 112.2 $6615 100% Heating: Fuel-fired air distribution, Propane, 97.0 AFUE. Heating: Fuet-fired air distribution, Propane, 97.0 AFUE. Criteria Cooling: Air conditioner, Electric, 16.0 SEER. This home meets or exceeds the minimum criteria for the following: Duct Leakage to Outside 80.00 CFM25. 2009 International Energy Conservation Code Ventilation System Exhaust Only: 81 cfm, 20.0 watts. 2012 International Energy Conservation Code Programmable Thermostat Heat=Yes; Cool=Yes IECC2012 with MA Amendments" Massachusetts Residential New Construction Program" Building Shell Features " Compliance is determined by the rater. Ceiling Flat R-38.0 Slab None Sealed Attic NA Exposed Floor R-30.0 Vaulted Ceiling R-37.8 Window Type U-Value: 0.300, SHGC: 0.280 Above Grade Watts R-21.0 Infiltration Rate Htg: 2113 Clg: 2113 CFM50 Foundation Watts R-0.0 Method Blower door test Rating Team Sustainable Energy Analytics Lights and Appliance Features 4 Militia Drive, Suite 6 Percent Interior Lighting 100.00 Range/Oven Fuel Propane Lexington,MA. 02421 ►� Percent Garage Lighting 100.00 Clothes Dryer Fuel Electric 781-652-8282 Refrigerator (kWh/yr) 693 Clothes Dryer EF 3.01 Energystar@sea.us.com Dishwasher Energy Factor 0.46 Ceiling Fan (cfm/Watt) 0.00 Certified Energy Rater: REM/Rate-Residential Energy Analysis and Rating Software v14.6.1 This information does not constitute any warranty of energy cost or savings. O 1985-2015 Noresco, Boulder, Colorado. The Home Energy Rating Standard Disclosure for this home is available from the rating provider. ENERGY STAR Certified Homes, Version 3 (Rev. 07) Thermal Enclosure System Rater Checklist Home Address: tOJ '12 pa City: NO Tit A P b W — ate: Zip Code: 1.High-Performance Fenestration Must Builders Rater NIA Correct Verified Verified 1.1 Prescriptive Path:Fenestration shall meet or exceed ENERGY STAR requirements 2 ❑ p ❑ 1.2 Performance Path:Fenestration shall meet or exceed 2009 IECC requirements 2 ❑ ❑ ❑ 2.Quality-installed Insulation 2.1 Ceiling,wall,floor,and slab insulation levels shall comply with one of the following options: 2.1.1 Meet or exceed 2009 IECC levels 3,4,5 OR; ❑ p ❑ 2.1.2 Achieves 133%of the total UA resulting from the U-factors in 2009 IECC Table 402.1.3, excluding fenestration and per guidance in Footnote 3d,AND home shall achieve<_50%of the O O O infiltration rate in Exhibit 1 of the National Program Requirements 4,5 2.2 All ceiling,wall,floor,and slab insulation shall achieve RESNET-defined Grade I installation or, alternatively,Grade 11 for surfaces that contain a layer of continuous,air impermeable insulation a R-3 O O O in Climate Zones 1 to 4,a R-5 in Climate Zones 5 to 8 3.Fully-Aligned Air Barriers At each insulated location noted below,a complete air barrier shall be provided that is fully aligned with the insulation as follows: •At interior or exterior surface of ceilings in Climate Zones 1-3;at interior surface of ceilings in Climate Zones 4-8.Also,include barrier at interior edge of attic eave in all climate zones using a wind baffle that extends to the full height of the insulation.Include a baffle in every bay or a tabbed baffle in each bay with a soffit vent that will also prevent wind washing of insulation in adjacent bays •At exterior surface of walls in all climate zones;and also at interior surface of walls for Climate Zones 4-8 7 •At interior surface of floors in all climate zones,including supports to ensure permanent contact and blocking at exposed edge s,e 3.1 Walls 3.1.1 Walls behind showers and tubs ❑ ❑ ❑ 3.1.2 Walls behind fireplaces ❑ ❑ p 3.1.3 Attic knee walls 11 ❑ ❑ ❑ 3.1.4 Skylight shaft walls ❑ ❑ 3.1.5 Wall adjoining porch roof ❑ ❑ 12, O 3.1.6 Staircase walls O O O 3.1.7 Double walls ❑ ❑ O RK 3.1.8 Garage rim/band joist adjoining conditioned space ❑ ❑ 3.1.9 All other exterior walls I O 3.2 Floors 3.2.1 Floor above garage ❑ ❑ 3.2.2 Cantilevered floor ❑ ❑ O 3.2.3 Floor above unconditioned basement or unconditioned crawlspace 0 14 IriNAL- O ❑ O 3.3 Ceilings 3.3.1 Dropped ceiling I soffit below unconditioned attic ❑ ❑ ❑ 3.3.2 All other ceilings A 0 Imet tA A L. ❑ ❑ O 4.Reduced ThermalBridging 4.1 For insulated ceilings with attic space above(i.e.,non-cathedralized),Grade I insulation extends to the inside face of the exterior wall below at these levels:CZ 1-5:a R-21;CZ 6-8:a R-3012 ❑ ❑ O 4.2 For slabs on grade in CZ 4 and higher,100%of slab edge insulated to R-5 at the depth specified by the 2009 IECC and aligned with thermal boundary of the walls 4,5 O ❑ ❑ ❑ 4.3 Insulation beneath attic platforms(e.g.,HVAC platforms,walkways)a R-21 in CZ 1-5;a R-30 in CZ 6-8 O O ❑ ❑ 4.4 Reduced thermal bridging at above-grade walls separating conditioned from unconditioned space(rim/band' sts exempted)using one of the following options: s 4.4.1 Continuous rigid insulation,insulated siding,or combination of the two; a R-3 in Climate Zones 1 to 4,>_R-5 in Climate Zones 5 to 8147$16,OR; O O O 11 4.4.2 Structural Insulated Panels(SIPS) 4,OR; ❑ ❑ O O 4.4.3 Insulated Concrete Forms(ICFs) ,OR; ❑ ❑ O O 4.4.4 Double-wall framing 14J7,OR; ❑ 0 O O 4.4.5 Advanced framing,including all of tbd Items below: ^� 4.4.5a All comers insulated a R edge ,AND; ❑ ❑ 0 O 4.4.5b All headers above ows&doors insulated a R-3 for 2x4 framing or equivalent cavity O ❑ ❑ width,and a R- or all other assemblies(e.g.,with 2x6 framing) ,AND; 4.4.5c Framing 1' ed at all windows&doors to one pair of king studs,plus one pair of jack studs per ow opening to support the header and sill 20,AND; O O O O 4.4.5 interior/exterior wall intersections insulated to the same R-value as the rest of the exterior wall 21,AND; O ❑ 11 ❑ 4.4.5e Minimum stud spacing of 16 in.o.c.for 2x4 framing in all Climate Zones and,in Climate Zones 5 through 8,24 in.o.c.for 2x6 framing 22 ❑ ❑ ❑ ❑ Effective for homes permitted starting 8/01/2013 Revised 6/01/2013 Page 3 of 16 ENERGY STAR Certified Homes, Version 3 (Rev. 07) Thermal Enclosure System Rater Checklist 6.Air Sealing Must I Builder I Rater NIA Correct Verified Verlfied 5.1 Penetrations to unconditioned space fully sealed with solid blocking or flashing as needed and gaps sealed with caulk or foam 5.1.1 Duct/flue shaft ❑ 5.1.2 Plumbing/piping ❑ ❑ ❑ 5.1.3 Electrical wiring ❑ ❑ ❑ 5.1.4 Bathroom and kitchen exhaust fans ❑ ❑ 5.1.5 Recessed lighting fixtures adjacent to unconditioned space ICAT labeled and fully gasketed. —/ Also,if in insulated ceiling without attic above,exterior surface of fixture insulated to�R-10 in ❑ M ❑ ❑ CZ 4 and higher to minimize condensation potential. 5.1.6 Light tubes adjacent to unconditioned space include lens separating unconditioned and conditioned space and are fully gasketed 23 ❑ ❑ ❑ 5.2 Cracks in the building envelope fully sealed 5.2.1 All above-grade sill plates adjacent to conditioned space seated to foundation or sub-floor with J caulk,foam,or equivalent material.Foam gasket also placed beneath above-grade sill plate if ❑ ❑ EJ resting atop concrete or masonry and adjacent to conditioned space 24,25 5.2.2 At top of walls adjoining unconditioned spaces,continuous top plates or sealed blocking using ❑ ❑ ❑ caulk,foam,or equivalent material 5.2.3 Drywall sealed to top plate at all unconditioned attic/wall interfaces using caulk,foam,drywall adhesive(but not other construction adhesives),or equivalent material.Either apply sealant ❑ le ❑ ❑ directly between drywall and top plate or to the seam between the two from the attic above. 5.2.4 Rough opening around windows&exterior doors sealed with caulk or foam 26 ❑ ❑ ❑ 5.2.5 Marriage joints between modular home modules at all exterior boundary conditions fully sealed ❑ ❑ with gasket and foam 5.2.6 All seams between Structural Insulated Panels(SIPS)foamed and/or taped per ❑ ❑ manufacturer's instructions 5.2.7 In multifamily buildings,the gap between the common wall(e.g.the drywall shaft wall)and the ❑ ❑ ❑ structural framing between units fully sealed at all exterior boundaries 5.3 Other openings 5.3.1 Doors adjacent to unconditioned space(e.g.,attics,garages,basements)or ambient conditions ❑ ❑ es' ❑ made substantially air-tight with weatherstripping or equivalent gasket 5.3.2 Attic access panels and drop-down stairs equipped with a durable a R-10 insulated cover that is gasketed(i.e.,not caulked)to produce continuous air seal when occupant is not accessing the ❑ ❑ [illi ❑ attic 5.3,3 Whole-h use fans equipped with a durable>R-10 insulated cover that is gasketed and either install e on a use side or mechanically operated 27 ❑ ❑ 0 01-1 Rater Name: r� ✓_t` f Rater Pre-Drywall Inspection Date: ' Z 1, 10'Rater Initials: V -- Rater Name: Rater Final Inspection Date: t d 201(f- Rater Initials: Builder Employee: Builder Inspection Date: Builder Initials: Notes: 1. At the discretion of the Rater, the builder may verify up to eight items specified in this Checklist. When exercised, the builder's responsibility will be formally acknowledged by the builder signing off on the checklist for the item(s)that they verified. 2. For Prescriptive Path:All windows, doors, and skylights shall meet or exceed ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights—Version 5.0 as outlined at www.enerovstar.00v/windows.For Performance Path:All windows,doors and skylights shall meet or exceed the component U-factor and SHGC requirements specified in the 2009 IECC—Table 402.1.1. If no NFRC rating is noted on the window or in product literature(e.g.,for site-built fenestration), select the U-factor and SHGC value from Tables 4 and 14, respectively, in 2005 ASHRAE Fundamentals,Chapter 31. Select the highest U-factor and SHGC value among the values listed for the known window characteristics(e.g., frame type, number of panes, glass color, and presence of low-e coating). Note that the U- factor requirement applies to all fenestration while the SHGC only applies to the glazed portion.The following exceptions apply: a. An area-weighted average of fenestration products shall be permitted to satisfy the U-factor requirements; b. An area-weighted average of fenestration products z 50%glazed shall be permitted to satisfy the SHGC requirements; c. 15 square feet of glazed fenestration per dwelling unit shall be exempt from the U-factor and SHGC requirements, and shall be excluded from area-weighted averages calculated using a)and b),above; d. One side-hinged opaque door assembly up to 24 square feet in area shall be exempt from the 1.1-factor requirements and shall be excluded from area-weighted averages calculated using a)and b),above; e. Fenestration utilized as part of a passive solar design shall be exempt from the U-factor and SHGC requirements, and shall be excluded from area-weighted averages calculated using a) and b),above. Exempt windows shall be facing within 45 degrees of true South and directly coupled to thermal storage mass that has a heat capacity>20 btu t fex°F and provided in a ratio of at least 3 sq.ft.per sq,ft.of South facing fenestration.Generally,thermal mass materials will be at least 2 in.thick. Effective for homes permitted starting 8/01/2013 Revised 6/01.12013 Page 4 of 16 SUSTAINABLE ENERGY ANALYTICS Energy Code Compliance Testing Results Testing Date 5/21/15, 10/20/15, 12/9/15 SEA# 2402 Project Address 107 Campion St,Andover,MA 01845 Permit# Client Company Century Builders, Inc Contact Name Glenn Saba Contact Phone 978-815-7073 Email gtsaba@outlook.com Tested By(Print) Jang Yoon Signed HERS Provider Performance Systems Development,Ithaca, NY Cert# 5240057 Tests Conducted: (Check all that apply) Massachusetts Base Code(IECC 2012)Test Options X Duct Test—All Types"Total Leakage" —4 CFM/100 ft2 Conditioned Floor Area Served Duct Test—Total Leakage without Air Handler—3 CFM/100 ft2 Conditioned Floor Area Served X Building Infiltration Test—3 ACH50 at 50 pa X Mechanical Ventilation-to meet ENERGY STAR13.0 or ASHRAE 62.2-2013 Standard(ERV,HRV,exhaust only bath fans) Stretch Energy Code Test Options Duct Test:New Construction,Rough-in'Total Leakage With Air Handler"—6 CFM/100 ft2 Conditioned Floor Area Duct Test:New Construction,Rough-in'Total Leakage Without Air Handler"—4 CFM/100 ft2 Conditioned Floor Area Duct Test:New Construction,Post Construction"Leakage to Outside"(LTO)—8 CFM/100 ft2 Conditioned Floor Area Duct Test:New Construction,Post Construction`Total Leakage"(Total)—12 CFM/100 ft2 Conditioned Floor Area Duct Test:Additions/Renovations,Post Construction"Leakage to Outside"—4 CFM/100 ft2 Conditioned Floor Area Building Infiltration Test—7 ACH50 at 50 pa Building Infiltration Test Results Building Volume(FT3) (Volume X Test Limit Req/60=CFM50) Test Result(CFM50) Pass/Fail 42289 2115 2113 PASS Duct Test Results Conditioned Area Served Test Limit Test Result Pass/Fail , System Description (FT2) (Conditioned Area*Req/100=CFM) (CFM) 11t Floor 2084 83 45 PASS(2.2%) 2nd Floor 2278 91 35 PASS(1.5%) Mechanical Ventilation Massachusetts Base Code Only(IECC 2012) Conditioned Area Served Test limit—CFM Test Result Pass/Fail System Description (FT2) (NBr+1)*7.5+1%CFA (CFM) Exhaust Only 4362 81 81 PASS F7 4 Militia Drivej i Suite • Lexingt6n, 02421 • • - • S 652 - • Enter construction cost for fee cal - North Andover Fee Calculation Construction Cost $ 545,000.00 m $ - $ 6,540.00 Plumbing Fee $ 817.50 Gas Fee 100 comm. $ 100.00 Electrical Fee $ 817.50 Total fees collected $ 8,275.00 107 Campion Road 562-15 on 12/17/2014 Single Family Home NORT1y Town of Andover too No. * C, h ver Mass 1:)L 9 1 (�- 1 O L-A�4E COCNICMt WICK � Q �V ds R�7ED /•P�`�,�5 U BOARD OF HEALTH Food/Kitchen PERMIT T LD Septic System THIS CERTIFIES THAT l/1. ..... &Ike4j,;, •... ,.. BUILDING INSPECTOR ........... ......... .............. r Foundation has permission to erect .......................... buildings on .... .... ............... 2 n Q Rough to be occupied as ....Q�.. :T ... ../..L.t..l..� f...... .{�.'4? ....... .... Chimney �( nu provided that the person accepting'tis permit shall in every respect conform to the terms of the applica Ion Final on file In this office, and to the provisions of the Codes and By-Laws relating to the Inspection, Alteration and Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR VIOLATION of the Zoning or Building Regulations Voids this Permit. Rough Final PERMIT EXPIRES IN 6 MONTHS ELECTRICAL INSPECTOR oo • cv . UNLESS CONSTRUCTIO ST TS Rough Service ....................................................... Final BUILDING INSPECTOR GAS INSPECTOR Occupancy Permit Required to Occupy Building Rough Display in a Conspicuous Place on the Premises — Do Not Remove Final No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. Burner Street No. Smoke Det. Gel ina5 Structural �ngineerinq LLC Phone 978.465.6436 Daniel L. Gelinas, P.E. Fax 978.465.5 160 579A North End Blvd. Salisbury, MA 01952-1738 email danlgelinas@comcast.net May 21, 2015 Brian Leathe, Local Building Inspector 1600 Osgood Street North Andover,MA 01845 bleathegtownofnorthandover.com Copy: Glenn T Saba Century Builders, Inc. 8 Brushwood Ave Atkinson NH 03811 gsabagcomcast.net SUBJECT: Structural Observations, 107 Campion Rd North Andover MA Dear Mr. Leathe : Gelinas Structural Engineering LLC (Gelinas)met you on site yesterday with Glenn Saba to review the framing at the above address. It is Gelinas' opinion: I. The LVL's observed where representative as those on the Gelinas Structural Drawings 2. In general the framing observed was representative of those on the Gelinas Structural Drawings 3. A few structural punch list items where identified 4. Today Mr. Saba forwarded photos and represented those punch list structural items have been installed 5. Thus given this information it is Gelinas Structural Engineering LLC' s opinion the LVL's observe and the framing observed are substantially complete and satisfy the structural requirements of the Gelinas drawings and IRC 2009 as amended by the Massachusetts Residential Code 8th Edition Amendment Please call with any questions, cell 978.360.2562 Very Truly Yours, � � (N -1 U)ATNI aFL L. ti T,R CA-URAL Pxu.43s'i;�A Y iA Job 1305 ml Daniel L. Gelinas,P.E May 21, 2015 L irc2009 mass res code 8th Y