HomeMy WebLinkAboutBuilding Permit #556-15 - 1514 SALEM STREET 12/16/2014 v f �. NORTF� O�tt�to ib�ti BUILDING PERMIT �r 4°::�. .•:.° °oma TOWN OF NORTH ANDOVER APPLICATION FOR PLAN EXAMINATION Permit NO: Date Received °9 •�=.: - �` '` Date Issued: 12 �9SSgcHUS IMPORTANT:Applicant must complete all items on this page LOCATION 1514 Salem St " ..Print 1' _0 PROPERTY OWNER Hillary Stasonis 4 # y . Print . MAP NO: 106.A PARCEL:A-0027 ZONING`DISTRiCT:�Historic District y esu(no Machine ShopVillage" yeso TYPE OF IMPROVEMENT PROPOSED USE Residential Non- Residential ❑ New Building I]One family ❑Addition E]Two or more family ❑ Industrial ❑Alteration No. of units: ❑ Commercial ❑ Repair, replacement ❑ Assessory Bldg ❑ Others: ❑ Demolition ✓❑Other Solar/PV ❑ Septic ❑Well ❑ Floodplain o Wetlands ❑ 'Watershed_,District ❑Water/Sewer . _ . Install 51 solar electric panels @13.005kW DC to roof of existing home, to be interconnected with the homes' electrical system Identification Please Type or Print Clearly) OWNER: Name: Hillary Stasonis Phone: (978)685-5929 Address: 1514 Salem St CONTRACTOR Name Phone: 978-215-2383 '1 10 a r r# SolarCity Corp V AaR y k . Address: A 800 Research Dr.Wilmington'Ma.'01887 , Supervisor's Construction License: 41. p. Ex Date:. 107663 ffi. X8/29/2017Tb . Home Improvement License: ' hl Exp.'Date:' 19 168572 3/8/2015_„ ARCHITECT/ENGINEER Phone: Address: Reg. No. FEE SCHEDULE:BULD/NG PERMIT:$12.00 PER$1000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PER S.F. Total Project Cost: $32,000 FEE: $ `� Check No.: -I4-DC31�s Receipt No.: NOTE: Persons contracting with unregistered co ractors do not have access to the guaranty fund o Signature of A�gent/Owner - _ Signature of contractor Li `VY- VIrA ►ZA l ie (M f Plans Submitted ❑✓ Plans Waived ❑ Certified Plot Plan ❑ Stamped Plans ❑✓ TYPE OF SEWERAGE DISPOSAL Public Sewer ❑ Tanning/Massage/Body Art ❑ Swimming Pools ❑ Well ❑ Tobacco Sales ❑ Food Packaging/Sales ❑ Private(septic tank,etc. ❑ Permanent Dumpster on Site ❑ THE FOLLOWING SECTIONS FOR OFFICE USE ONLY INTERDEPARTMENTAL SIGN OFF - U FORM DATE REJECTED DATE APPROVED PLANNING & DEVELOPMENT ❑ ❑ COMENTS CONSERVATION ❑ ❑ COMMENTS DATE REJECTED DATE APPROVED HEALTH ❑ ❑ COMMENTS { 1 Zoning Board of Appeals:Variance, Petition No: Zoning Decision/receipt submitted yes Planning Board Decision: Comments Conservation Decision: Comments Water & Sewer Connection/Signature& Date Driveway Permit Located at 384 Osgood Street � FIRE DEA Ti1jENT T mp _rnpster on site yes " Located at 124 Main Sheet x Fiire bepartmer t signature/date _ COMMENTS z 4 NORTH BUILDING PERMIT pFst�eo bgti0 TOWN OF NORTH ANDOVER - APPLICATION FOR PLAN EXAMINATION _ � o•Pq a. Permit No#: Date Received �SSACHU`��� Date Issued: IMPORTANT:Applicant must complete all items on this page LOCATION Print PROPERTY OWNER_ ,._ . �.. =rw Pnn# F00 Year Structure Yes no MAP PARCEL _ ZONING R:ISTRICT . Historie District yes no Machine Shop Village Yes. n° TYPE OF IMPROVEMENT PROPOSED USE Non- Residential Residential ❑ New Building ❑ One family [I Addition El Two or more family [I Industrial ❑Alteration No. of units: ❑ Commercial ❑ Repair, replacement ❑Assessory Bldg ❑ Others: ❑ Demolition ❑ Other ww -a -- = w- -- ❑ Septic El Well b 4Floodplan Wetlands. ❑ Watershed tDstriot El Water/Sewer-s DESCRIPTION OF WORK TO BE PERFORMED: Identification- Please Type or Print Clearly Phone: OWNER: Name: Address: k Contractor Name:=- `Phone Addresg: Supervisor's Construction License: __ Exp: Date: Home Improvernent'License ARCHITECT/ENGINEER Phone: Address: Reg. No. FEE SCHEDULE:BULDING PERMIT:$12.00 PER$1000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PER S.F. Total Project Cost: $ FEE: $ Check No.: Receipt No.: NOTE: Persons contracting with unregistered contractors do not have access to the guaranty fund Signature of-Agent/Owner _ _-_-__ Si nature of contracto __ - _- I 1 Building Department The following is a list of the required forms to be filled out for the appropriate permit to be obtained. Roofing, Siding, Interior Rehabilitation Permits o Building Permit Application a Workers Comp Affidavit o Photo Copy Of H.I.C. And/Or C.S.L. Licenses o Copy of Contract o Floor Plan Or Proposed Interior Work u Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit Addition Or Decks Li Building Permit Application a Certified Surveyed Plot Plan o Workers Comp Affidavit a Photo Copy of H.I.C. And C.S.L. Licenses o Copy Of Contract Li Floor/Cross Section/Elevation Plan Of Proposed Work With Sprinkler Plan And Hydraulic Calculations (If Applicable) u Mass check Energy Compliance Report (If Applicable) u Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit New Construction (Single and Two Family) o Building Permit Application Li Certified Proposed Plot Plan a Photo of H.I.C. And C.S.L. Licenses o Workers Comp Affidavit o Two Sets of Building Plans (One To Be Returned) to Include Sprinkler Plan And Hydraulic Calculations (If Applicable) o Copy of Contract - o Mass check Energy Compliance Report o Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg. Permit iIn all cases if a variance or special permit was required the Town Clerks office must stamp the decision from the Board of Appeals that the appeal period is over. The applicant must then get this recorded at the Registry of Deeds. One copy and proof of recording must be submitted with the building application Doe:Building Permit Revised 2014 Plans Submitted ❑ Plans Waived ❑ Certified Plot Plan ❑ Stamped Plans ❑ i TypF'OF SEWERAGE DISPOSAL Public Sewer ❑ Swimmin Pools ❑ Tanning/MassageBody Art ❑ g Well ❑ Tobacco Sales ❑ Food Packaging/Sales ❑ Private(septic tank,etc. ❑ Permanent Dumpster on Site ❑ !I i THE FOLLOWING SECTIONS FOR OFFICE USE ONLY i INTERDEPARTMENTAL SIGN OFF - U FORM PLANNING & DEVELOPMENT Reviewed On Signature_ COMMENTS CONSERVATION Reviewed on Signature COMMENTS HEALTH Reviewed on Signature ` COMMENTS ZoningBoard . of Appeals: Variance Petition ion No: Zoning Decision/receipt submitted yes Planning Board Decision: Comments Conservation Decision: Comments Water & Sewer Connection/Signature& Date Driveway Permit DPW Town Engineer: Signature: --� Located 384 Osgood_Street FIRE DEPARTMENT - Temp Dumpster on situ es 4 Y L-ocated,At 124 Main Street - _ Fire'Department!signature/date z -- - COMMENTS _ _. ■ I Dimension Number of Stories: Total square feet of floor area, based on Exterior dimensions. Total land area, sq. ft.: ELECTRICAL: Movement of Meter location, mast or service droprequires q approval of Electrical Inspector Yes No DANGER ZONE LITERATURE: Yes No MGL Chapter 166 Section 21A—F and G min.$100-$1000 fine NOTES and DATA— (For department use) i i i E � I i ❑ Notified for pickup Call Email i I Date Time Contact Name Doc.Building Permit Revised 2014 i Location No. �t!!t ` A Date -2��� . - TOWN OF NORTH ANDOVER ,o Certificate of Occupancy $ Building/Frame Permit Fee $ Foundation Permit Fee $ Other Permit Fee TOTAL $ l� c� Check 4t `U j� r F �k✓_ 28362 Building Inspector NORT-H Town of I. Andover Ai�_ t\ No. - * _ z m� Vol261q h ver, Mass o Ic"t q. CO[KICKl WICA w"K 04C ra S U BOARD OF HEALTH Food/Kitchen PERM T L D Septic System THIS CERTIFIES THAT "44 �. . A0 .................................................. BUILDING INSPECTOR has permission to erect .........."thisper buildi on ...� .%45 �r w..% ���,�.'�,',,............ Foundation .. .. .....`��..I. ....� Rough to be occupied as .... .. ...................... c provided that the person accepshall in every resp�t conform to the terms of the application Final on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection,Alteration and �6 Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR VIOLATION of the Zoning or Building Regulations Voids this Permit. Rough Final PERMIT EXPIRES IN 6 MONTHS ELECTRICAL INSPECTOR UNLESS CONt2tBU1'L­D­1­ Rough Service NSPE TOR. Final O� ?_?_ /( GAS INSPECTOR Occupancy Permit Required to Occupy Building Rough Display in a Conspicuous Place on the Premises — Do Not Remove Final No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. Burner Street No. Smoke Det. emr*A.4 CpfrcL P Version#61.4 aAsolar Cit Y Project/Job# 0181341 RE: Installation Approval Letter Project: Stasonis Residence 1514 Salem St North Andover, MA 01845 Date of Review 7/7/2016 AH] North Andover SC Office Wilmington To Whom It May Concern, On the above referenced project,the roof structural framing has been reviewed for additional loading due to the installation of the solar PV addition to the roof.The structural review, including the plans and calculations only apply to the section of roof that is directly supporting the solar PV system and its supporting elements. The capacity of the structural roof framing directly supporting the additional gravity loading due to the solar panel supports and modules had been reviewed and determined to be in accordance with the requirements of the MA Res. Code,8th Edition. . s The work has been completed in accordance of the provisions of the approved permits of the applicable code. Should you have any further questions or requirements pertaining to this project, please do not hesitate to contact me. .Yoo Jin Kim, P.E. Professional Engineer OF "44 T: 510.647.6816 email: ykim@solarcity.com � �o Y00 AN !f V No.4 6 H SSS ALS\ Digitally s Yoo Jin Kim Date:201 .07.07 11:56:52 -07'00' 3055 Clearviev7 Way San Mateo,CA 94402 T(650)638-1028 (888)SOL-CITY F(650)638-1029 solarcity.com aL V55rp,0.R M-8'.31-10C 1.13771/rte'.145450 0 C'SLB 1F34.CJ ECEO4+CT H.0 aS.-z7:ifi.,::Vt'?:,;05 rh-,'410514�_',7+'uC�+EGC.9UZ.'.:95.DE W)rllo4da T1 6'�W tL EC13L».9,2_u Ht C f 2WJ iLIS•7051 MA H-i%3571 EL 1116MR,MD"L11897 P,178-: NC IV801L.NM V+Ir,,t2!,2tM.NJ`d.IM�p12VHCt4ix++E00r3aEBV1iS17C11 NMEE9857959V.t1v FiY2072113517T/Gt 007854376?.7070159.Ort EC 4/7U7.OE+fSl9+'�".cF 1512 L0.rxr F'ATrIr 4.1.1 At W47V,keg 38SU.TA rECLZJ006.L'll8,2'9-0-55'-'1.VAELL27U5l3279,✓TEM-C'38ZV.MASC'LM? - OlfSOLAXC'91tA?,A;L,ry439,G,w,,A�406.Nwsau H240971LIX'Q,�Inem PC4W 1.F—kran7H-+11"40{'rj.��Snff..Y 511'`,7-H,Wef!�-hecler W C-26W-1111 F1rC pA0G138a OCA Sf rf,rL.NICi n.Mbw:r.,.an pt2f10.p0')A4E5.155'.t"rlea S:.Eth FI.UrVtq Efr.•Hyn.Ny tlTVl/2'aL1956-D CA N:..ar.p.nd,+!kM`-!arC•ryFinxn.:9< m(_.anri.. CAF Lentlnra L.�.anra bU$41^/,SA.0tyF­w•..m�,.any.LLC r anxetll tl Del .a•e$t l 8 kC,mmraxwnzr l�en¢age nbua�ne>L nDelx..ar¢Lmdar 11 enax numt:ar V:94t1 MD(­—t anL anaa eta+.^ry h t9nnn+L'-an( ,..1711023.1010.4 AI Lr etl..entlx LL"3lC3I.L.TkR.wtaYerse Cr•.tl'.or 140W509ES^Z'Ja"4M Vl t•ntlar l..a..a,x 676E J�Has-� Location '` , ) as , ��� �� No. �. ��� I Date sit - 1(5 • TOWN OF NORTH ANDOVER I . . .a Certificate of Occupancy $ Building/Frame Permit Fee $ Foundation Permit Fee $ Other Permit Fee $ `S VW [, 5 TOTAL $ Check# 1591 f 30582 Building Inspector � NORT!-r over Town of C 0 No. 'j�Q Z I(el 2811 ver Ma ss, OIC HE �. COCHIC HI WICK ga� r Ireace V■ � 7,ps R�{TED PP �y L) BOARD OF HEALTH Food/Kitchen PERML D Septic System THIS CERTIFIES THAT ........��.... .. ........ ? BUILDING INSPECTOR ... ............ ....... ............. has permission to erect ........... ........ buildi on ...� 5kkmn. ;5role ,',,............ Foundation ... .... G� Rough to be occupied as ..... 3 .... . . . ...... . .. ... ... ........U.-..�. .... ........................... c provided that the person accepting this per it shall in every respet conform to the terms of the application � Final on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection,Alteration and Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR VIOLATION of the Zoning or Building Regulations Voids this Permit. Rough Final PERMIT EXPIRES IN 6 MONTHS ELECTRICAL INSPECTOR UNLESS CONt2t4BU14LDIN Rough Service ..kTOR7 Final E GAS INSPECTOR Occupancy Permit Required to Occupy Building Rough Display in a Conspicuous Place on the Premises — Do Not Remove Final No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. Burner Street No. Smoke Det. ?e P mro." CArreL Massachusetts L-lectric Company M.D.P.U.No_1176 Nantucket FILetricCompany Canceling M.D.T.E.No. I I WA STANDARDS FOR INTERCONNECTING DISTRIBUTED GENERATION ATTACHMENT 2 Certificate of Completion for Simplified Process Interconnections Installation Information: El Check if owner-installed Customer or Company Name(print): HillaryStasonis Contact Person, if Company: Mailing Address: 1514 Salem $t city: North Andover state: MA Zip Code: 01845 Telephone(Primary): 9786855929 Telephone(Secondary): Fax: Email: hillary@stasonis.com Facility Address(If different from above): City: State: Zip Code: Account Number. 03989-12019 Meter Number: 14089803 Electrical Contractor's Company or Name(print): SolarCity Corp. Electrician Name,if Company: Matthew T. Markham Mailing Address: 24 St. Martin Drive city: Marlborough She: MA Zip code: 01752 = Telephone(Primary): 774-258-8505 Telephone(Secondary): 978-995-6584 Fax: 978-429-0898 Email: mmarkham@solarcity.com License.number: MR1136 Date of approval to install Facility granted by the Company: Application ID number: Inspection: The system has been installed and inspected in compliance with the local Building/Electrical Code or: North Andover (Citylriown) j Signed(Local Electrical Wiring Inspector,or attach signed electrical inspection): Wiring Inspector Name(printed): Phone Number Email Address: As a condition of interconnection you are required to email a copy of this form along with a copy of the signed electrical permit to distributed.generation@us.ngrid.com us.ngrid.com F OORTH Town of ndover p 0 No. 6640P ( �yy ys , h over, Mass, COCN1CMt WICK V� ADRATED lkPP�,�S S V BOARD OF HEALTH Food/Kitchen PER L D Septic System THIS CERTIFIES THAT ........................ . 1. ...... . .. ..... ........,,,,,,,, ,,,, , , ... BUILDING INSPECTOR Foundation has permission to erect ... .................... buildin son .... 5.A.... .. .. ... ..... Rough la to be occupied as 1.... . .. .. .. .... .�........ 3�.a.0 ... ......... Chimney provided that the person accepting this permit shall in every respect conform to the terms of the application Final on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection,Alteration and Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR VIOLATION of the Zoning or Building Regulations Voids this Permit. Rough Final PERMIT EXPIRES IN 6 M AL ELECTRICAL INSPECTOR UNLESS CONSTRUCTIO Rough Service .................. .. ...... .................. Final BUILDING INSPECTOR GAS INSPECTOR Occupancy Permit Required to Occupy Building Rough Display in a Conspicuous Place on the Premises — Do Not Remove Final No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. Burner Street No. Smoke Det. i The Commonwealth of Massachusetts Department of Industrial Accidents UP Office of Investigations I Congress Street,Suite 100 - Boston,MA 02114-2017 www massgov/dia Workers Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbe rs A>N>Alicant Information Please Print Ler- Name e ibl Name(Business/Organization/individual) SOLARCITY CORP Address:3055 CLEARVIEW WAY City/State/Zip-SAN MATEO,CA 94402 phone 41:888-765-2489 Are you an employer?Check the appropriate box: Type of project(required): 1A I am a employer with 5000_ 4. ❑ 1 am a general contractor and 1 6 0 New construction employees(full and/or part-time).* have hired the sub-contractors 2.0 l am a sole proprietor or partner- listed on the attached sheet. 7. 0 Remodeling ship and have no employees These sub-contractors have g. 0 Demolition working for me in any capacity. employees and have workers' 9 0 Building addition (No workers' comp. insurance comp.insuranee.t required) 5. 0 We are a corporation and its 10.❑Electrical repairs or additions 3.0 1 am a homeowner doing all work officers have exercised their 11.0 Plumbing repairs or additions myself: [No workers' comp. right of exemption per MGL 12,0 Roof repairs insurance required.]t c. 152,§1(4),and we have no SOLAR i PV employees. [No workers' 13.0 Other comp.insurance required.] *Any applicant that checks box 41 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. tContractors that check:this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contactors have employees,.th)mut provide their workes'oom .policY number. I am an employer that is providing workers'compensation Insurance for my employees. Below is fire policy and Job site infotamatlon. Insurance Company Name:LIBERTY MUTUAL INSURANCE COMPANY Policy#or Self-ins. Lic.#:uWA7-66D-066265-024a Expiration Date-09/011/2015 Job Site Address: S 6 L SC, e s•�.�C . City/State/Zip: IV ti /'t-vdt,— I-,\A Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required'under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine st the violator. Be advised that a co of this statement may be forwarded to the Office of to 250.00 a da against Y of $ y g copy up Investigations of the DIA for insurance coverage verification. I do hereby certify funder the pains and e�taides of per,jrrry that the ipfformation provided above is true and correct. .P Phone# Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): I.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: , ,!R" CERTIFICATE OF LIABILITY INSURANCE DATE IYYYY➢ THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endomemenL A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsement(s). PRODUCER CT NAAE MARSH RISK&INSURANCE SERVICES -- - kx 345 CALIFORNIA STREET,SUITE 1300 ffix No F/U_,C No]: CALIFORMA LICENSE NO.0437153 EMAIL SARI FRANCISCO,CA 94104 ADDRESS INSURER(&)AFFORDING COVERAGE NIUC X M301-STND-GANUE-14-15 INSURER A:Libe ty MAW Fire hwance Canpany 165% If ISu Ph(650)9635100 INSURER 13:Ub"Insuronce Corporation 42404 lWaiOly Capor4on INSURER C:WA - NIA 3055 Gearvim way INSURER D: San Mateo,CA 94402 — INSURER E INSURER F: COVERAGES CERTIFICATE DUMBER: SEA-00244026942 _ REVISION NUMBER:4 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS. EXCLUSIONS AND CONOITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. iR ADDL B POLICY EFFPOLICY EXP LIMITS TYPE OF INSURANCE POLICY NUMBER M MIDD A GENERAL LIABILITY TB2.661-066265-014 0910112014 0910112015 EACH OCCURRENCE X D A TO RENTED 100,000 COMMERCIAL GENERAL LIABILITY $ _ CLAIMS-MADE i.-1 OCCUR MED EXP Any one pmon) S 10,000 PERSONAL&ADV INJURY S 1`000,000 GENERAL AGGREGATE $ 2,000AW GEICL AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/O_PAGG S 2,0009W X POLICY X PRO- LOC Deductible S 25,000' JFGT A AUTOktoBILE LIA Al Fry AS2-661-066265.044 09/0111014 09ID112015 COMBINED tl SIN L IT 1.000,000 �Ea_aocidan lixANYAUTO BODILY INJURY(Per Person)ALL OWNED SCHEDULED BODILY INJURY(Per accident) S AUTOS HtREDAUTOS X AUTOWMED POS POP�a DAMAGEPhys.Damage COMPICOLL DEO: $ 511000151.000 UMBRELLA UAB OCCUR EACH OCCURRENCE S EXCESS LIAB CLAIMS MADE AGGREGATE S DED RETENTION$ S B WORRMSCOMPENSATION WAMD-066265-024 0910112014 09/0112015 X VdC STATU- OTH- B AND EMPLOYERS'LIABILITY ORYIIM! ER Y/N WC7 661 066265 034(WI) ({91(1111014 09/0112015 ANY PROPRIETORIPARTNERIEXECUTIVE E.L EACH ACCIDENT $ 1'000'000 B OFFICERWEMBER EXCLUDED? N/A VC DEDUCTIBLE:5350,000 •�•� {maanif sdatory in NH) E.L.ElDISEASE-EA EMPLOYE S _ DESCRIPTION OF 0 TIONS below E.L.DISEASE-POLICY LIMIT $ 1'� DESCRIPTION OF OPERATIONS 7 LOCATIONS I VEHICLES(Attach ACORD 101,Additional RsmaAta Schedule,it more space is required) Evdenw .of klsurarwe. CERTIFICATE HOLDER CANCELLATION WarCiV Carpotetion SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 3055 ClearAew fty THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN San Mateo.CA 94402 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh Risk a Insurance Services Charles Marrltolejo O 1918-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010105) The ACORD name and logo are registered merits of ACORD Office of Consumer Affairs"and Business Regulation 10 Park Plaza - Suite 5170 4,''°` Boston Massachusetts 021 .16 Home Improvement Contractor Registration Registration: 168572 Type: Supplement Card SOLARCITY CORPORATION Expiration: 3/8/2015 CRAIG ELLS _-- 24 ST. MARTIN STREET BLD 2 UNIT 11 -- — --- - -- MARLBOROUGH, MA 01752 Update Address and return card.Mark reason for change. SCA t 0 20W05111 El Address El Renewal 0 Employment D Lost Card ?lfr, rIN%tri/r rr.♦/��lr r!'�/rrl;.trr��rr.f//, Office of Consumer Affairs&Business Regulation License or registration valid for individul use only expiration date. If found return to:h before the ex � --I��ME IMPROVEMENT CONTRACTOR bp IF1i Office of Consumer Affairs and Business Regulation Registration: 168572 TYP( 10 Parte Plaza-Suite 5170 r i. Expiration: 3/8/2015 Supplement :ard PP Boston,MA 02116 SOLARCITY CORPORATION CRAIG ELLS f. 24 ST MARTIN STREET BLD ZUNI �►� 1 �l?/� IIIA&LBOROUGH,MA 01752 -. ..— - Undersecretary Not v lid without signature Wssachusetts •Department of Public Safety Board of Building g Regulations and Stnnoards f�tt+C�uziis 4��I ��g�ti,r License. CS407663 •wP.�, 2 . { CRAIG ELLS - 206 BAKER STREET Keene NH 03431' I _ . Ganurrisa�ranrr 08/29/2017 L./f7,G (QQ�1??%??,(�?,�,l,�C�•G��l�;1� , C--��G C :I Q�l?�f�.�� Office of Consumer Affairs d Business Regulation 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement.Contractor Registration Registration: 168572 Type: Supplement Card.. YP PP 4 SOLARCITY CORPORATION I'r: Expiration: 3/8/2015 DAVID MILLAR 24 ST. MARTIN STREET BLD 2 UNT�s11 `�; MARLBOROUGH, MA 01752 � . Update Address and return card.Mark reason for change. SCA 1 t', 20M-05111 E] Address 0 Renewal F] Employment n Lost Card ffice of Affairs Consumer i ars&Business Regulation License or registration valid for indiividul use only I ` ME rIMPROVEMENT CONTRACTOR before the expiration date: If found return to: Office of Consumer Affairs and Business Regulation egistration: 168572 Type, 10 Park Plaza-Suite 5170 Expiration: 8/812015 Supplement+'ard Boston,MA 02116 SOLARCITY CORPORATION DAVID MILLAR ' �r -- / 24 ST MARTIN STREET BLD 2UIJI _ ITAAhLBOROUGH,MA 01752 Undersecretary Not va d withbut signature DocuSign Envelope ID:F8B5634A-71CD-49OB-8EBF-77F7A2D716C7 7. ADDITIONAL RIGHTS TO CANCEL. IN ADDITION TO ANY RIGHTS YOU MAY HAVE TO CANCEL THIS AGREEMENT UNDER SECTION 8 BELOW AND UNDER SECTION 1 OF THE GENERAL TERMS AND CONDITIONS, YOU MAY CANCEL THIS AGREEMENT, INCLUDING ANY SUBSEQUENT AMENDMENT, AT NO COST AT ANY TIME PRIOR TO COMMENCEMENT OF CONSTRUCTION ON YOUR HOME. 8. NOTICE OF RIGHT TO CANCEL. YOU MAY CANCEL THIS AGREEMENT AT ANY TIME PRIOR TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE DATE YOU SIGN THIS AGREEMENT. SEE THE ATTACHED NOTICE OF CANCELLATION FORM ATTACHED AS EXHIBIT i FOR AN EXPLANATION OF THIS RIGHT. Customer's Name:Chris Stasonis DocuSigned by: Signature: �(,VtS Sfa.SMAAS Date: so,. 12/6/2014 Customer's Nag&qjllav Stasonis u gne by: Signature: Ctl �fASbIMS Date: "" w„o` o.o,... 12/6/2014 vAsolarCit y Solar Home Improvement Agreement SOLARCITY APPROVED Signature: r--� LYNDON RIVE,CEO Solar Home Improvement Agreement �eSola city. Date: 11/25/2014 Solar Home Improvement Agreement MyPower Solar Plan,version 3.2.0,November 11th,2014 Copyright©2008-2014 SolarCity Corporation.All Rights Reserved ❑■ a 418079 �r} �t � DocuSign Envelope ID:F8B5634A-71CD-490B-8EBF-77F7A2D716C7 W SolarCity I MyPower Homeowner Chris Stasonis Date Issued 11/25/2014 Address 1514 Salem St Installation Location 1514 Salem St North Andover, MA 01845 North Andover, MA 01845 Our estimates show that you can own your solar power system from day one and save on your electricity bill. Equivalent rate per kWh I 0 b 25.20 0 16m190 Loan Down Payment Before rate reduction payment After rate reduction payment Our Promises to You System Warranty: We repair the system at no additional cost. Free monitoring: We provide 24/7 web-enabled monitoring at no additional cost. Rooftop warranty:We warrant your roof against leaks. Production Guarantee: Your system will produce as much electricity as we promise or we'll pay you. Fixed rate average:The rate you pay us will never increase by more than 2.9% per year.' No prepayment penalty:You can,prepay your loan at any time with no penalty or fee.' Estimated-System Size 13.005 kW Estimated First Year Production 10,475 kWh I i Your SolarCity MyPower Agreement i Total System $71,528 APR 4.5 % Cost I REC Value 414;306 Term 30 Years Utility RebateFederal Tax - $21,458 Value -$0 Credit3 30%of eligible system cost I kWh Rate $21,458 Loan Amount $57,222 Reduction Payment Due June 1 st the year after installation These features are provided through a loan by SolarCity Finance Company, LLC z This rate includes a 0.5%discount for using auto-pay from your checking account. 3 To realize the benefit of the federal tax credit, customer must have federal income tax liability that is at least equal to the i value of the tax credit. SolarCity Corporation MA HIC 168572/EL-1136MR.The MyPower loan is being provided by SolarCity Finance Company LLC 418079 [oil P NO] NJ l Version#39.5 �aaoaCt OF 3055 Y t 3055 Clearview Way, San Mateo, CA 94402 p� YOO A (888)-SOL-CITY (765-2489) 1 www.solarcity.com K November 17,2014 Vr ya No.A Project/Job#0181341 .O RE: CERTIFICATION LETTER r..A AL Project: Stasonis Residence Digitall S by Yoo Jin Kim 1514 Salem St North Andover, MA 01845 Date: 2014.11 .17 14:49:45 To Whom It May Concern, -081001 A jobsite survey of the existing framing system was performed by a site survey team from SolarCity. Structural review was based on site observations and the design criteria listed below: it Design Criteria: -Applicable Codes = MA Res. Code,8th Edition,ASCE 7-05,and 2005 NDS - Risk Category= II -Wind Speed = 100 mph, Exposure Category C -Ground Snow Load = 50 psf - MP1&2: Roof DL=7.5 psf, Roof LL/SL= 38.5 psf(Non-PV Areas),Roof LL/SL= 38.5 psf(PV Areas) -MP3: Roof DL= 8.5 psf,Roof LL/SL= 35.5 psf(Non-PV Areas), Roof LL/SL= 19.5 psf(PV Areas) Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.33365 < 0.4g and Seismic Design Category(SDC) =C < D On the above referenced project,the components of the structural roof framing impacted by the installation of the PV assembly have been reviewed. After this review it has been determined that the existing structure requires structural upgrades as detailed in the plan set to withstand the applicable roof dead load, PV assembly load,and live/snow loads indicated in the design criteria above. I certify that the structural roof framing including the specified upgrades and the new attachments that directly support the gravity loading and wind uplift loading from PV modules have been reviewed and determined to meet or exceed structural strength requirements of the MA Res. Code,8th Edition. Please contact me with any questions or concerns regarding this project. Sincerely, Yoo Jin Kim, P.E. Professional Engineer Main: 888.765.2489,x5743 email: ykim@solarcity.com 3055 Clearview Way San Mateo,CA 94402 T(650)638-1028 (888)SOL-CITY F(650)638-1029 solarcity.com AZ f10C 243771.CA C51.8 888104,CO EC 8041,Ci HIC 0832778 DG r11C 0`1101488.DC tits 71101488,Ht CI 28770,MA HIC 166572.MD MH1C 128948.NJ 1:tYH06180600, OR CCR 1110498,PA 077343 TX MLR 27000 WA GCt. SC'�ARC'919n7 0 2013 S*WCAty Ati ttyht,t—ry»d i + 11.17.2014 !a �f SleekMountTM PV•System Version#39.5 .l i-1��SOl �It y Structural Design Software I PROJECT INFORMATION &TABLE OF CONTENTS —__ —- r Project Name:- Stasonis Residence _ _ AHJ: North Andover Job Number: 0181341 Building Code: MA Res.Code, 8th Edition Customer Name: P, Stas-on-ii,-'Chris ,Based On: - IRC 2009/IBC 2009 Address: 1514 Salem St ASCE Code: ASCE 7-05 _North Andover, MA Risk Category: _-II - Zip Code 01845 _Upgrades Req'd? Yes Latitude/Longitude:- _42.651979 . - -71.063873 ____Stamp•Req'd? - Yes _ SC Office: Wilmington PV Designer: Matt Morse Calculations: Justin Arbuckle - :OR: Yoo Jin Kim P.E. Certification Letter 1 Project Information, Table Of Contents, &Vicinity Map 2 Structure Analysis (Loading Summary and Member Check) 3 Hardware Design (PV System Assembly) 4 Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.33365 < 0.4g and Seismic Design Category(SDC) =C < D 1 2-MILE VICINITY-IM AP Cn A D qi MassGIS. Commonwealth of Massac usetts EO'E-A\USDA Farm Service Agency aaa 9S! , - 1514 Salem St, North Andover, MA 01845 Latitude:42.651979, Longitude: -71.063873,Exposure Category:C f LOAD ITEMIZATION - MP1&2 PV System Load PV_Module Weight(psf) _ _ - _ _ - 2.5 psf Hardware AssemblyWeight(ps 0.5 sf PV System Weight s 3.0 psf Roof Dead Load Material Load Roof Category Description . MP1&2 Roofing Type _m . Comp,Roof ( 1 Layers)'€ _ 2.5 psf Re-Roof to 1 Layer of Comp? No Underlayment_ _ Roofing Paper 0.5 psf Plywood Sheathing Yes 1.5 psf Board Sheathing r __ ,- None _ Rafter Size and Spacing 2 x 6 @ 16 in. O.C. _ 1.7 psf Vaulted Ceiling No _r Miscellaneous Miscellaneous Items 1.3 psf Total Roof Dead Load 7.5 psf MP1&2 7.5 Psf Reduced Roof LL Non-PV Areas Value ASCE 7-05 Roof Live Load _ Lo 20.0 psf Table 4-1 Member Tributary Area - At < 200 sf w ._ Roof Slope 6/12 Tributary Area Reduction _ Rl 1 LL _ Section 4.9 Sloped Roof Reduction RZ_ 0.925 Section 4.9 Reduced Roof Live Load Lr 4= Lo(Ri)(Rz) Equation 4-2 Reduced Roof Live Load Lr 18.5 psf MPi&2 18.5 Psf Reduced Ground/Roof Live/ now Loads Code Ground Snow Load p9 50.0 psf ASCE Table 7-1 Snow Load Reductions Allowed? Yes Effective Roof Slope 250 , Horiz.-Distance.from Eve to Ridge _ W'- _. 13.8 ft _ Snow Importance Factor IS 1.0 Table 1.5-2 ' Partially Exposed - - Snow Exposure factor Ce'' 1.0 Table 7-2 Snow Thermal Factor Ct Structures kept just above freezing Table 7-3 1.1 Minimum Flat Roof Snow Cc7ad(w/ a 38.5 psf 7.3.4&7.10 Rain-on-Snow,Surcharge) _ _ pf""'" Flat Roof Snow Loadpf=0.7(Ce)(Ct)(I) pg; pf a pf-min Eq: 7.3-1 Pf 38.5 psf 77% ASCE Design Sloped Roof Snow Load Over Surrounding Roof Surface Condition of Surrounding CS-roof All Other Surfaces Figure 7-2 Roof 1.0 Design Roof Snow Load Over Ps-roof= (Cs-roof)Pf ASCE Eq: 7.4-1 SurroundingRoof ps-roof 38.5 psf 77% ASCE Design Sloped Roof Snow Load Over PV Modules Surface Condition of PV Modules CS_PV Unobstructed 1.0 pery Surfaces Figure 7-2 Design Snow Load Over PV PS-PV= (Cs-pv)Pf ASCE Eq: 7.4-1 Modules Ps p" 38.5 psf 77% I COMPANY PROJECT WoodWorkso Nov. 17, 2014 12:11 MP1&2.wwb Design Check Calculation Sheet Wood Works Sizer 10.1 Loads: Load Type Distribution Pat- Location [ft] Magnitude Unit tern Start End Start End DL Dead Full Area No 7.50 (16.0) * psf PV LOAD Dead Full Area No 3.00 (16.0) * psf SNOW LOAD Snow Full Area No 38.50 (16.0) * psf LIVE IRoof constr. Full Area No 18.50 (16.0) * psf *Tributary Width (in) Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) : 14'-2.4,. 0' 0'-11" 12'-6" Unfactored• Dead 105 91 Snow 346 301 Roof Live 166 145 Factored: Total 450 392 Bearing: F'theta 490 490 Capacity Joist 5693 2204 Supports 3957 - Anal/Des Joist 0.08 0.18 Support 0.11 - Load comb #3 #3 Length 3.50 1.50 Min req'd 0.50* 0.50* Cb 1.11 1.00 Cb min 1.75 1.00 Cb support 1.13 - I Fcp sup335 - *Minimum bearing length setting used: 1/2"for end supports Bearing for wall supports is perpendicular-to-grain bearing on top plate. No stud design included. MP1&2 Lumber n-ply, S-P-F, No.1/No.2, 2x6, 2-ply (3"x5-1/2") Supports: 1 -Lumber Stud Wall, S-P-F (S) Stud; 2 - Hanger; Roof joist spaced at 16.0"c/c; Total length: 14'-2.4"; Pitch: 5.8/12; Lateral support: top=full, bottom=at supports; Repetitive factor: applied where permitted (refer to online help); WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN MPI&2.wwb WoodWorks®Sizer 10.1 Page 2 Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2012 : Criterion Analysis Value . Design Value Analysis/Design Shear fv = 29 Fv' = 155 fv/Fv' = 0.19 Bending(+) fb = 879 Fb' = 1504 fb/Fb' = 0.58 Bending(-) fb = 22 Fb' = 1504 fb/Fb' = 0.01 Deflection: Interior Live 0.43 = L/356 0.86 = L/180 0.51 Total 0.56 = L/273 1.28 = L/120 0.44 Cantil. Live -0.11 = L/112 0.14 = L/90 0.80 Total -0.14 = L/86 0.20 = L/60 0.69 Additional Data: FACTORS: F/E(psi)CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC# Fv' 135 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 3 Fb'+ 875 1.15 1.00 1.00 1.000 1.300 1.00 1.15 1.00 1.00 - 3 Fb' - 875 1.15 1.00 1.00 1.000 1.300 1.00 1.15 1.00 1.00 - 3 Fcp' 425 - 1.00 1.00 - - - - 1 1.00 1.00 - - E' 1.4 million 1.00 1.00 - - - - 1.00 1.00 - 3 CRITICAL LOAD COMBINATIONS: Shear LC #3 = D+S, V = 347, V design = 321 lbs Bending(+) : LC #3 = D+S, M = 1107 lbs-ft Bending(-) : LC #3 D+S, M = 28 lbs-ft Deflection: LC #3 = D+S (live) LC #3 = D+S (total) D=dead L=construction S=snow W=wind I=impact Lr=roof constr. Lc=concentrated All LC's are listed in the Analysis output Load combinations: ASCE 7-10 / IBC 2012 CALCULATIONS: Deflection: EI = 29e06 lb-in2/ply "Live" deflection = Deflection from all non-dead loads (live, wind, snow...) Total Deflection = 1.00 (Dead Load Deflection) + Live Load Deflection. Bearing: Allowable bearing at an angle F'theta calculated for each support as per NDS 3 .10.3 Desitin Notes: 1. WoodWorks analysis and design are in accordance with the ICC International Building Code(IBC 2012), the National Design Specification (NDS 2012), and NDS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Continuous or Cantilevered Beams: NDS Clause 4.2.5.5 requires that normal grading provisions be extended to the middle 2/3 of 2 span beams and to the full length of cantilevers and other spans. 4. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. 5. SLOPED BEAMS: level bearing is required for all sloped beams. 6. The critical deflection value has been determined using maximum back-span deflection. Cantilever deflections do not govern design. _ _..__. __.-_-_.__, -. - _ ..._._. �ALCULATION,OF D--ESI-GN WIND LOADS-MPI&2 Mounting Plane Information Roofing Material Comp Roof PV_System Type _ ^ _ , _-_ - _ - _ _ _ _ 'SolarCity.SleekMountTM Spanning Vents _ No - - Standoff Attachment Hardware y Com Mount T e C Roof Slope - - 250 -- •. Rafter Spacing _ — �16"O.C. Framing Type Direction Y-Y Rafters _ Purlin.Spacing_ X-X Purlins Only _ NA Tile Reveal Tile Roofs Only NA Tile Attachment System Tile Roofs Only_ _ _ __ NA iStanding Seam Spacing SM Seam Only NA Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method _ Partially/Fully Enclosed Method Basic Wind Speed V 100 mph Fig. 671 Exposure Category _ M _ _ �. . __ __w_ C _ _ Section 6.5.6.3 Roof Style Gable Roof Fig.6-11B/C/D-14A/B -_ _ . --_ -_ _ __ _ _ Mean Roof Height h 25 ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.95 Table 6-3 Topographic Factor KA.� _._ _ _ 1.00 Section 6.5.7 Wind Directionality Factor Kd - 0 85 Table 6-4 Importance Factor I _ te=a 1.0 Table 6-1 Velocity Pressure qh qh = 0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 20.6 psf Wind Pressure Ext. Pressure Coefficient U GC -0.88 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient Down GC 'r' 0.45 Fig.6-11B/C/D-14A/B Design Wind Pressure p =qh(GC) Equation 6-22 Wind Pressure U -18.0 Psf Wind Pressure Down 10.0 Psf ALLOWABLE STANDOFF SPACINGS _. X-Direction Y-Direction Max(Allowable Standoff Spacing— Landscape _ r _ 64"_ _ 39" _ NA Max.Allowable Cantilever___-� _ Landscape ._. _ " Standoff Configuration Landscape Staggered Max�StandoffTributary.Area_____ _ _ Trib 17s PV Assembly Dead Load _- W-PV __ T _��.-3 psf� _ Net Wind Uplift at Standoff__ __ T-actual�, �__ -282,Ibs Uplift Capacity of Standoff — T-allow_ _ 500 Ib_s Standoff Demand/Capacity I DCR W _ 56.3% X-Direction Y-Direction Max Allowable Standoff Spacing__-._ - _ Portrait 32" 64"__ Max Allowable Cantilever _ _ __.Portrait_ _ : 15' _ _ _ .,-NA Standoff Configuration Portrait Staggered Max;,Standoff_Tributary_Area _ Trb __ _ " :, 14 sf_ PV Assembly Dead Load W-PV 3 psf, Net,Wind Uplift at Standoff.­_ , _ _ T-actual,__- ., -235 lbs____ Uplift Capacityof Standoff T-allow 500 lbs Standoff Demand/Capacity DCR -.. ,Q' 47.0% r tLOAD ITEMIZATION PV System Load PV Module Weight(psf) _ 2.5 psf Hardware Assembl Weight s W _ 0.5 sf PV S stem Weight s 3.0 psf Roof Dead Load Material Load Roof Category Description MP3 Roofing Type _w •r _ Comp Roof ( 1 Layers) 2.5 psf Re-Roof to 1 Layer of Comp? No Underlayment _ _ v Roofing Paper 0.5 psf Plywood SheathingYes 1.5 psf Board Sheathing _ _ _None -- Rafter Size and Spacing -- 2 x 10 @ 16 in. O.C. _2.9 psf - Vaulted Ceiling.- No _ Miscellaneous Miscellaneous Items 1.1 pst Total Roof Dead Load 8.5 psf MP3 8.5 psf Reduced Roof LL Non-PV Areas Value ASCE 7-05 Roof Live Load Lo 20.0 psf Table 4-1 Member Tributary.Area At - 200 sf Roof Slope 10/12 TributaryArea Reduction _0._ Rl 1 Section 4.9 Sloped Roof Reduction Rz 0.7 Section 4.9 Reduced Roof Live Load Lr° 4= Lo(Rt)(R2) Equation 4-2 Reduced Roof Live Load Lr 14 psf MP3 14.0 Psf Reduced Ground/Roof Live/Snow Loads Code Ground Snow Load p9 50.0 psf ASCE Table 7-1 Snow Load Reductions Allowed? Yes i Effective Roof Slope 400 Horiz..Distance from Eve to Ride W_ _- _. _ 16.0 ft Snow Importance Factor IS 1.0 Table 1.5-2 Partially Exposed Snow Exposure Factor _ Ce 1 0 Table 7-2 Snow Thermal Factor Ct Structures kept just above freezing Table 7-3 1.1 Minimum Flat Roof Snow Load'(w/ Rain-on-Snow Surcharge) pf-mios 38.5 psf e. 7.3.4&7.10 Flat Roof Snow Load Pf pf= 0.7(Ce) (Ct) (I) pg; pf>_ pf-min Eq: 7.3-1 38.5 psf 77% ASCE Design Sloped Roof Snow Load Over Surroundinq Roof Surface Condition of Surrounding All Other Surfaces Roof Cs-goof Figure 7-2 0.9 Design Roof Snow Load Over Ps-roof= (cs-roof)Pf ASCE Eq: 7.4-1 Ps-roof SurroundingRoof 35.5 psf 71% ASCE Design Sloped Roof Snow Load Over PV Modules Surface Condition of PV Modules C,_PV Unobstructed Slippery Surfaces Figure 7-2 0.5 Design Snow Load Over PV PS-PV= (Cs-pv)Pf ASCE Eq: 7.4-1 Modules Ps p" 19.3 psf 39% COMPANY PROJECT WoodWorks® mFTWARF FOR W0013 nrsrciv Nov. 17, 2014 12:12 mp3.wwb Design Check Calculation Sheet WoodWorks Sizer 10.1 Loads: Load Type Distribution Pat- Location [ft] Magnitude Unit tern Start End Start End DL Dead Full Area No 8.50 (16.0) * psf PV LOAD Dead Full Area No 3.00 (16.0) * psf SNOW LOAD Snow Full Area No 35.50 (16.0) * psf LIVE lRoof constr. Full Area No 14.00 (16.0) * psf *Tributary Width (in) Maxi mum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) : 14'-2.4" i 0' 2'-2" 12'4" Unfactored: Dead 127 85 Snow 350 235 Roof Live 138 93 Factored: Total 477 320 Bearing: F'theta 492 492 Capacity Joist 2858 1106 Supports 2198 - Anal/Des Joist 0.17 0.29 Support 0.22 - Load comb #3 #3 Length 3 .50 1.50 Min' req'd 0.76** 0.50* Cb 1.11 1.00 Cb min 1.49 1.00 Cb support 1.25 - Fcp SU2 335, - *Minimum bearing length setting used: 1/2"for end supports **Minimum bearing length governed by the required width of the supporting member. Bearing for wall supports is perpendicular-to-grain bearing on top plate. No stud design included. MP3 Lumber n-ply, S-P-F, No.1/No.2, 2x10, 1-ply (1-1/2"x9-1/4") Supports:1 -Lumber Stud Wall, S-P-F (S) Stud; 2-Hanger; Roof joist spaced at 16.0"c/c; Total length: 14'-2.4"; Pitch: 6/12; Lateral support: top=full, bottom=at supports; Repetitive factor: applied where permitted (refer to online help); WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN mp3.wwb WoodWorks®Sizer 10.1 Page 2 Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2012 : Criterion Analysis Value Design Value Analysis/Design Shear fv = 28 Fv' = 155 fv/Fv' = 0.18 Bending(+) fb = 418 Fb' = 1273 fb/Fb' = 0.33 Bending(-), fb = 85 Fb' = 637 fb/Fb' = 0.13 Deflection: Interior Live 0.09 = <L/999 0.75 = L/180 0 .12 Total 0.12 = <L/999 1.13 = L/120 0.11 Cantil. Live -0.05 = L/541 0.32 = L/90 0.17 Total -0.07 = L/397 1 0.48 = L/60 1 0.15 Additional Data: FACTORS: F/E(psi)CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC# Fv' 135 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 3 Fb'+ 875 1.15 1.00 1.00 1.000 1.100 1.00 1.15 1.00 1.00 - 3 Fb' - 875 1.15 1.00 1.00 0.500 1.100 1.00 1.15 1.00 1.00 - 3 Fcp' 425 - 1.00 1.00 - - - - 1.00 1.00 - - E' 1.4 million 1.00 1.00 - - - - 1.00 1.00 - 3 Emin' 0.51 million 1.00 1.00 - - - - 1.00 1.00 - 3 CRITICAL LOAD COMBINATIONS: Shear : LC #3 = D+S, V = 304, V design = 257 lbs Bending(+) : LC #3 = D+S, M = 746 lbs-ft Bending(-) : LC #3 = D+S, M = 151 lbs-ft Deflection: LC #3 = D+S (live) LC #3 = D+S (total) D=dead L=construction S=snow W=wind I=impact Lr=roof constr. Lc=concentrated All LC's are listed in the Analysis output Load combinations: ASCE 7-10 / IBC 2012 CALCULATIONS: Deflection: EI = 139e06 lb-in2 "Live" deflection = Deflection from all non-dead loads (live, wind, snow...) Total Deflection = 1.00 (Dead Load Deflection) + Live Load Deflection. Bearing: Allowable bearing at an angle F'theta calculated for each support as per NDS 3.10.3 Design Notes: 1. WoodWorks analysis and design are in accordance with the ICC International Building Code(IBC 2012), the National Design Specification (NDS 2012), and NDS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Continuous or Cantilevered Beams: NDS Clause 4.2.5.5 requires that normal grading provisions be extended to the middle 2/3 of 2 span beams and to the full length of cantilevers and other spans. 4. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. 5. SLOPED BEAMS: level bearing is required for all sloped beams. 6. The critical deflection value has been determined using maximum back-span deflection. Cantilever deflections do not govern design. •1V (C-ALCULATIONWOF DESIGN WIND:LOADS - MP3--- Mounting Plane Information RootLng Material _ a _ , Comp Roof PV System Type _. __®_ _ __ - _ _ __SolarCitySleekMountTM Spannning Vents _ No Standoff Attachment Hardware Com Mount T e C Roof Slope 400 Rafter Spacing_ _ _ _ X16"O.C. Framing Type Direction Y-Y Rafters Purlin Spacing_ �. -.X-X Purlins Only Tile Reveal _ _ Tile Roofs Only NA TiletAttachment System, _ Tile Roofs Only _ _ Standing Seam Spacing SM Seam Only NA I Wind Design Criteria Wind Design CodeASCE 7-05 Wind Design Method _ Partially/Fully Enclosed Method_ Basic Wind Speed V 100 mphFig. 6-1 Exposure Category C Section 6.5.6.3 Roof Style Gable Roof Fig.6-11B/C/D-14A/B Mean Roof Height h 25 ft I Section 6.2 I Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.95 Table 6-3 Topographic Factor T_ Krt _ _ _ . __1-6-0 -.. m _ Section 6.5.7 Wind Directionality Factor Kd 0.85 _ _Table 6-4 �_ _ _�__ �� -- -_._ Im ortance Factor I 1.0 _ _ _ - Table 6-1 qh = 0.00256(Kz)(Krt)(Kd)(V^2)(I) Velocity Pressure qh Equation 6-15 20.6 psf I Wind Pressure Ext. Pressure Coefficient U GC -0.95 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient Down GC 0.88 Fig.6-118/C/D-14A/B Design Wind Pressure p p =qh(GC ) Equation 6-22 Wind Pressure Up pfup) -19.6 psf Wind Pressure Down 18.0 Psf ALLOWABLE STANDOFF SPACINGS i X-Direction Y-Direction Max Allowable Standoff Spacing Landscape _ .- �64" 39" Max Allowable Cantilever_ __ _ Landscape v _ _= ___. —24. Standoff Confi uration Landscape Staggered Max Standoff Tributary_Area. . _ Trib 17 sf ®� _ PV Assembly Dead Load_ W-PV 3 psf Net Wind Uplift at Standoff ci _T-actual Uplift Capacity of Standoff �_� _ _ - T-allow 500 lbs _�r_. . ._._....�_ Standoff Ca a Demand ci DCR 62.6% X-Direction Y-Direction Max Allowable Standoff Spacing_ _Portrait _-_-.-._ _- 7 - -7- 48° ______-�,v__.�. 64" _ Max Allowable Cantilever _ _Portrait_ _r. i -_ _ 20"— Standoff 0"_Standoff Configuration Portrait Staggered Max Standoff Tributary_Area�_ Trib__ _ = _�21_sf--__—__ PV Assembly Dead Load W-PV 3 psf i Net Wind—Uplift_at_Standoff_ �y,T- actual` lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 78.3% I • ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE _ 1. THIS SYSTEM IS GRID—INTERTIED VIA A AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIORE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. 1 CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING P01 POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 STRUCTURAL VIEWS LICENSE GENERAL NOTES PV5 THREE LINE DIAGRAM Cutsheets Attached GEN #168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION /\ ELEC 1136 MR OF THE MA STATE BUILDING CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: ZEP SOLAR AHJ: North Andover REV BY DATE COMMENTS REV A NAME DATE COMMENTS UTILITY: National Grid USA (Massachusetts Electric) i No CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-01 81341 00 PREMISE OWNER: DESCRIPTION: DESIGN: �ufr CONTAINED SHALL NOT BE USED FOR THE STASONIS, CHRIS STASONIS RESIDENCE Matt Morse � SolarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 1514 SALEM ST 9.435 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MoouLFs NORTH ANDOVERMA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH , 24 St. Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (37) CANADIAN SOLAR # CS6P-255PX SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE T. (650)B38-1028.F: (6A1752 636-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE # SE7600A—USOOOSNR2 (978) 685-5929 COVER SHEET PV 1 11/17/2014 (666)-SOL—CITY(765-2469) www.solarcity.aam PITCH: 25 ARRAY PITCH:25 MPI AZIMUTH: 138 ARRAY AZIMUTH: 138 MATERIAL: Comp Shingle STORY: 2 Stories PITCH: 25 ARRAY PITCH:25 F MP2 AZIMUTH:318 ARRAY AZIMUTH:318 MATERIAL: Comp Shingle STORY: 2 Stories YOO JIN K PITCH: 40 ARRAY PITCH:40 VII MP3 AZIMUTH:228 ARRAY AZIMUTH: 228 ------------- -__-_---_-_ MATERIAL: Comp Shingle STORY: 2 Stories 1 A / / ER" / c / Digital s PALy Yoo Jin Kim Date: 014.11.17 14:50:29 -08'00' / ZdW 1 1 1 1 g LEGEND J � AC 1 ® I Tj O (E) UTILITY METER & WARNING LABEL 1 nt House IDv INVERTER W/ INTEGRATED DC DISCO J1 ® ® O & WARNING LABELS O ® © DC DISCONNECT & WARNING LABELS �MPl A © AC DISCONNECT & WARNING LABELS 0 DC JUNCTION/COMBINER BOX & LABELS Q DISTRIBUTION PANEL & LABELS LC LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER Q STANDOFF LOCATIONS (E)DRIVEWAY CONDUIT RUN ON EXTERIOR --- CONDUIT RUN ON INTERIOR 1514 Sa�eln s1 — GATE/FENCE Q HEAT PRODUCING VENTS ARE RED (� '( INTERIOR EQUIPMENT IS DASHED L=/J SITE PLAN ti Scale:1/16" = 1' O1' 16' 32' s F bu- CONFlDENTIAL- THE INFORMATION HEREIN JOB NUMBER: JB-01 813 41 00 PREMISE OWNER: DESCRIPTION: - - - — DESIGN: STASONIS, CHRIS STASONIS RESIDENCE j.'SolarCity. CONTAINED SHALL NOT BE USED FOR THE Matt Morse �. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �•� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 1514 SALEM ST 9.435 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION HATH [MODULES*- NORTH ANDOVER, MA 01845 24 St.Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (37) CANADIAN SOLAR # CS6P-255PX REv DATE. Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME T. (650)638-1028 F: (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE # SE7600A-USOOOSNR2 (978) 685-5929 SITE PLAN PV 2 11/17/2014 (BBB)-SOL-CITY(765-2489) ww.Warcity.com PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER U1c & FENDER WASHERS 2x6 SPF#2 (N) 2'-2" (E) 2x4 LOCATE RAFTER, MARK HOLE Si ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) (2) PSO'AL PILOT HOLE WITH ZEP COMP MOUNT C YURETHANE SEALANT. (E) LBW (E) LBW ZEP FLASHING C (3) (3) INSERT FLASHING. A SIDE VIEW OF MP1 NTS SISTER UPGRADE INFORMATION: RAFTER UPGRADE INDICATED BY HATCHING (E) COMP. SHINGLE (1) (4) PLACE MOUNT. UPGRADE NOTES: (E) ROOF DECKING (2) V MPJ IX-SPACINGIX-CANTILEVER Y-SPACING Y-CANTILEVER NOTES 1. CUT AND ADD (N) SISTER AS SHOWN IN THIS SIDE VIEW AND REFERENCED TOP VIEW. (5) INSTALL LAG BOLT WITH LANDSCAPE 64" 1 24" 1 STAGGERED 2. FASTEN (N) SISTER TO (E) MEMBER W/ SIMPSON SDW 22300 (IF 2—PLY) OR 22458 5/16" DIA STAINLESS (5) SEALING WASHER. PORTRAIT 1 32" 1 15" ROOF AZ Ise PITCH zs (IF 3—PLY) SDW SCREWS STAGGERED AT 16" O.C. ALONG SPAN AS SPECIFIED, IF STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT W I ITH RAFTER 2x6 @ 16"OC ARRAY AZI Iia PITCH zs STORIES:2 WOOD SPLITTING IS SEEN OR HEARD, PRE—DRILL WITH A �" DRILL BIT. WITH SEALING WASHER (6) C.J. 2x8 @16"OC Com Shin 5 ALT. OPTION FOR FULL LENGTH MEMBERS ONLY— FASTEN (N) SIDE MEMBER TO " BOLT & WASHERS. (E) RAFTER W/ 10d (IF 2—PLY) OR 16d FROM EACH SIDE (IF 3-PLY) COMMON (2-1/2' EMBED, MIN) NAILS AT 6" O.C. ALONG SPAN. (E) RAFTER •SISTER ALL RAFTERS ON THIS MP SECTION INTO WHICH THE ARRAY IS LAGGED 1 STAN DOFF witµOF YQO JIN K I y No.4 o 11L Digitally i y Yoo An Kim 6" END Date:2014.11.17 14:50:35 SIMPSON SDW 22300 WOOD tr SCREWS (E) RAFTER DISTANCE -08'00' (E) WALL OR (N) SISTER MEMBER CENTERED (E) RIDGE BOARD 6"—,f--16" O.C. TYP.--,' (E) 2x6 RAFTER SUPPORT BELOW BETWEEN SUPPORTS OR SUPPORT BELOW 2y4" — — � SEE MP SIDE VIEW FOR REQUIRED LENG1t' � SIMPSON SDW WOOD SCREWS (N) 2x6 SIDE MEMBER Dl D1 _ MIR _ *JQP__YIEW OF PARTIAL LENGTH SISTER D1 2x6 END FASTENER GROUPING Scale. 3/4 —1-0 Scale. 1 —1-0 CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER DESMPTION: DESIGN: JB-0181341 00 \\` . CONTAINED SHALL NOT BE USED FOR THE STASONIS, CHRIS STASONIS RESIDENCE Matt Morse BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM �,,`SolarCit NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 1514 SALEM ST 9.435 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH ' 24 St.Martin Drive,Building 2 Unit 11 THE SALE AND USE OF THE RESPECTIVE (37) CANADIAN SOLAR # CS6P-255PX PAGE NAME: SHEET: REN DALE Matin Drive, MA ing Z SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN [%0TIEDGE T: (650)638-1028 F: (650)636-1029 PERMIs�oN of soLARCITY INC. SE760OA—USOOOSNR2 (978) 685-5929 STRUCTURAL VIEWS PV 3 11/17/2014 (Bas)-SCI-CITY(765-2489) www.solarcity.com t%k F ( ) 2x6 YQO IN `�`� �IN >� S1 K U2 2x6 SPF#2 2'-1'i VI N No.4 .o T S1 A Digitally si o Jin Kim Date:201 .11.17 14:50:41 (E) LBW • -O8'00' SIDE VIEW OF MP2 NTS SISTER UPGRADE INFORMATION: RAFTER UPGRADE INDICATED BY HATCHING 77 B UPGRADE NOTES: (E) LBW MP2 I X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES 1. CUT AND ADD (N) SISTER AS SHOWN IN THIS SIDE VIEW AND REFERENCED TOP VIEW. SIDE VIEW OF MP3 LANDSCAPE 64" 24" 1 ISTAGGERED 2. FASTEN (N) SISTER TO (E) MEMBER W/ SIMPSON SDW 22300 (IF 2-PLY) OR 22458 NTS PORTRAIT 1 32" 15" 1 1 (IF 3-PLY) SDW SCREWS STAGGERED AT 16' O.C. ALONG SPAN AS SPECIFIED, IF ROOF AZI 318 PITCH 25 RAFTER 2x6 @ 16"OC ARRAY AZI 318 PITCH 25 STORIES:2 WOOD SPLITTING IS SEEN OR HEARD, PRE—DRILL WITH A J' DRILL BIT. C.I. 2x8 @16"OC Comp Shingle ALT. OPTION FOR FULL LENGTH MEMBERS ONLY- FASTEN (N) SIDE MEMBER TO MP3 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES (E) RAFTER W/ 10d (IF 2-PLY) OR 16d FROM EACH SIDE (IF 3-PLY) COMMON LANDSCAPE 64" 24" STAGGERED NAILS AT 6" O.C. ALONG SPAN. PORTRAIT 1 48" 20" •SISTER ALL RAFTERS ON THIS MP SECTION INTO WHICH THE ARRAY IS LAGGED ROOF AZI228 PITCH 40 RAFTER 2X10 @ 16"OC ARRAY AZI 228 PITCH 40 STORIES: 2 C.I. 2x10 @16"OC Comp Shingle 6" END SIMPSON SDW 22300 WOOD SCREWS (E) RAFTER DISTANCE (E) WALL OR (N) SISTER MEMBER CENTERED (E) RIDGE BOARD �`�`� -16" O.C. TYP.�' (E) 2x6 RAFTER SUPPORT BELOW BETWEEN SUPPORTS OR SUPPORT BELOW 2Y4, , fill III SEE MP SIDE VIEW FOR REQUIRED LENGTH All SIMPSON SDW WOOD SCREWS (N) 2x6 SIDE MEMBER D2 D2 MIR _ TOP VIEW OF PARTIAL LENGTH SISTER 02 2x6 END FASTENER GROUPING JB-01 813 41 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED L A THE INFORMATION HEREIN JOB NUMBER: STASONIS, CHRIS STASONIS RESIDENCE Matt MorseBEN \�l�SO�a�C�t CONTAINED SHALL NOT E USED FOR THE _/••„ NOR SHFIT LL ANYONE EXCEPT IN MOLE INC., MOUNTING SYSTEM: 9.435 KW PV ARRAY 1 NOR SHALL IT BE OUTSIDE T IN WHOLE T' IN Comp Mount Type C 1514 SALEM ST PART TO OTHERS OUTSIDE THE RECIPIENT'S y. ORGANIZATION, EXCEPT IN CONNECTION WITH IMODUn- NORTH ANDOVER, MA 01845 THE SALE AND USE OF THE RESPECTIVE (37) CANADIAN SOLAR # CS6P-255PX 24 Sc.Martin Drive,Building 2,Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: Marlborough,MA 01752 PERMISSION OF SMENTTY INC. INVERTER: T: (650)638-1028 F: (650)638-1029 SOLAREDGE # SE760OA—USOOOSNR2 (978) 685-5929 STRUCTURAL VIEWS PV 4 11/17/2014 (888)–SOI--CITY(765-2489) ww.solarally.aom GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO TWO (N) GROUND Panel Number:GE Inv 1: DC Ungrounded INV 1 -(1)SOLAREDGE ## SE760OA-USOOOSNRLABEL: A -(37)CANADIAN SOLAR CS6P-255PX GEN #168572 ODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:14089803 Inverter; 76'OOW, 24C 97.5�a w$nifed Disco and ZB, RGM, AFCI PV Module; 255W#234.3W PTC, Black Frame, MC4, ZEP Enabled ELEC 1136 MR Overhead Service Entrance INV 2 Voc: 37.4 Vpmax: 30.2 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL E 20OA/2P MAIN CIRCUIT BREAKER SolarCity (E) WIRING Inverter 1 CUTLER-HAMMER 4 A > 200A/2P Disconnect 5 SOLAREDGE Dc. - SE7600A-US000SNR2 Dc- P 1 and 2: 1x19 (E) LOADS B - -------- -- Ecc------------------ L1 zaov r--------- 4 �- L2 DCr I I N DG I 3 2 I 40A/2P ____ GND _-_ _ EGG/ DC+ - I ---------------------------------- --- A I GEC T N DG Dc- P 2 and 3: 1x1 I 6 GND EGC ---------�(I)Conduit ------------ ---�---- -- EGC-----------------tJ I -- I I N I Kit; 3/4'.EMT - _J o EGC/GEC_ z � � I I I I I I - GEC TO 120/240V SINGLE PHASE I I I I UTILITY SERVICE I I I I I • I I I I I I PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Voc* = MAX VOC AT MIN TEMP P0I (1)GE y THOL2140 PV BACKFEED BREAKER B (1)CUTLER-HAMMER #DG222UREI /f\ A (1)SolarCity#4 STRING JUNCTION BOX D� Breaker, 40A/2P, 2 Spaces Disconnect; 60A, 24OVoc,Non-Fusible, NEMA 3R A 2x2 STRMGS, UNFUSED, GROUNDED -(2)Ground Rod; 5/8'x 8', Copper -(1)CUTLER-XMMER �I DG100N6 Ground/Neutral Kit; 60-100A, General Duty(DG) PV 07)SOLAREDGE 300-2NA4AZS PowerBox Optimizer, 30OW, H4, DC to DC, ZEP nd (1)AWG #6, Solid Bare Copper -(1)Ground Rod; 5/8' x 8',Copper (N) ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION NO. 2, ADDITIONAL ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE 1 AWG#8, THWN-2, Block (1)AWG/10, THWN-2, Black Voc* =500 VDC Isc =15 ADC (2)AWG#10, PV WIRE, Black Voc* =500 VDC Isc =15 ADC O (1)AWG#8, THWN-2, Red O (1)AWG#10, THWIN-2, Red Vmp =350 VDC Imp=12.94 ADC O (1)AWG #6,Solid Bare Copper EGC Vmp =350 VDC Imp=13.66 ADC (I)AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=32 AAC 0 AWG#10, THWN72, Green. ECC. . . . . . . . . . . . . .70)AWG A.THWN72,Green . . EGC/GEC,-(1)Conduit.Kit;.3/4`.EMT. . . .. , , . . . (1 AWG 110, THWN-2, Black Voc* =500 VDC Isc =15 ADC (2)AWG X10, PV WIRE Black Voc* =500 VDC Isc =15 ADC ®ff (1)AWG#10, THWN-2, Red Vmp =350 VDC Imp=13.66 ADC O (1)AWG #6, Solid Bare Copper EGC Vmp =350 VDC Imp=12.94 ADC 1)AWG/10. THYMI-2,.Green EGC .. . . .. .. .. . . .. . . .. . . . ... .. .. .. .. . . . . . . . . .. . . . ... . . .. .. .. .. .. .. .. CONFIDENTIAL- THE INFORMATION HEREIN [INVERTER: B NUMBER PREMISE OWNER: DESCRIPTION: DESIGN- CONTAINED 00 CONTAINED SHALL NOT BE USED FOR THE STASONIS, CHRIS STASONIS RESIDENCE Matt Morse BENEFIT OF ANYONE EXCEPT SOLARCITY INC., UNTING SYSTEM: :;,SolarCity. NOR SHALL IT BE DISCLOSED IN WHOLE OR INomp Mount Type C 1514 SALEM ST 9.435 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS outls NORTH ANDOVER MA 01845 TTHORGANIZATION, �SA E¶D USES OF IN RES ECT01vE�TM 37) CANADIAN SOLAR # CS6P-255PX � g 2,Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN 24 Si Martin Drive,Building 01 p PAGE NAME SHEEP: REV DATE Marlborough,MA 01752 PERMISSION OF SOLARgTY INC. 978 685-5929 T: (650)638-1028 F: (650)638-1029 OLAREDGE SE7600A-USOOOSNR2 ) THREE LINE DIAGRAM PV 5 i�/17/2ot4 (88B)-SOL-CITY(765-2469) wwr.salaraiiy.ean Label Location: Label Location: Label Location: •' 0 0 0 '0 0 - (C)(CB) o (�]/��� (AC)(POI) � o (�� (DC)(INV) Per Code: Per Code: _ uV _ Per Code: NEC 690.31.G.3 °otwai :a@ NEC 690.17.E ° ° ° o- o 4,apNEC 690.35(F) Label Location: ° - 0 0 0 TO BE USED WHEN o•° INVERTERIS (DC)(INV) Q�I �= ° Per Code: UNGROUNDED D 0 NEC 690.14.C.2 Label Location: Label Location: (POI) •° (DC) (INV) Per Code: 'O Per Code: o ° °- NEC 690.64.B.7 ` ' •° - NEC 690.53 °o 0 o- i• Label Location: (POI) Label Location: - ° ° Per Code: o (DC) (CB) °o o"0 NEC 690.17.4; NEC 690.54 Per Code:o : � °=0011110 NEC 690.17(4) AWN °- -o ° -o - I(►9 °• 00 •- �� Label Location: o f�llri� (DC) (INV) Label Location: UVJ_ Per Code: ��ny� (D) (POI) • -o °�° ® �'° ° NEC 690.5(C) SUV Per Code: o- -o ° ° 0 0 0�-• ° NEC 690.64.6.4 Label Location: Label Location: 0 (POI) O 0 O (AC)(POI) ° -o - o - Per Code: (AC):AC Disconnect D � Per Code: 0 I - NEC 690.64.B.4 (C): Conduit 0 NEC 690.14.C.2 (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect Label Location: (IC): Interior Run Conduit Label _ (INV): Inverter With Integrated DC Disconnect A - (AC) (POI) - — – (LC): Load Center ---- °' Per Code: - NEC 690.54 -- (M): Utility -- - °- �T - (POI): Point of Interconnection CONFIDENTIAL— THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR ���r�I ®C®EI® THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR MALL IT BE DISCLOSED �. soomnnrir IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, SC Label Setola�it T ' EXCEPT IN CONNECTION WITH.THE SALE AND USE OF THE RESPECTIVE I� ®OLO Y SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. o SolarCity SleekMountTM - Comp SolarCity SleekMountTM - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed �> Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM modules r aesthetics while minimizing roof disruption and 10Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and Interlock and grounding devices in system UL listed to UL 2703 Fastener Size Per NDS Section 1.1.3.2 mounting clamps, combined with the addition of array trim and a lower profile all contribute •Interlock and Ground Zep ETL listed to UL 1703 Seal pilot hole with roofing sealant to a more visually appealing system.SleekMount as"Grounding and Bonding System" `, a 0 Insert Comp Mount flashing under upper utilizes Zep Compatible TM modules with •Ground Zep UL and ETL listed to UL 467 as layer of shingle strengthened frames that attach directly to grounding device O Place Comp Mount centered Zep Solar standoffs, effectively eliminating the need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition .Anodized components for corrosion resistance Q5 Install lag pursuant to NDS Section 11.1.3 shingles are not required to be cut for this with sealing washer. system, allowing for minimal roof disturbance. •Applicable for vent spanning functions -- Secure Leveling Foot to the Comp Mount • using machine Screw O7 Place module ® Components ® 5/16"Machine Screw ® ® Leveling Foot © Lag Screw ® Comp Mount © © Comp Mount Flashing o`. ® ;t ;`SolarCity. LISTED /" t January 2013 <O O SDla�i` ® January 2013 "MPP V ry ee5;g� ®0i , CS6P-235/240/245/250/255PX ,veakt�tpp8�� ®r Canad�anSolar Electrical Data Black-framed STC CS6P-235P CS6P-240P CS6P-245P CS6P-250PXCS6P-255PX Temperature Characteristics Nominal Maximum Power(Pmaz) 235W 240W 245W 25OW 255W Optimum Operating Voltage(Vmp) 29.8V 29.9V 30.OV 30.1V 30.2V Pmax -0.43 rC -yy Optimum Operating Current(Imp) 7.90A 8.03A 8.17A 8.30A 8.43A Temperature Coefficient Voc -0.34%/°C Open Circuit Voltage(Voc) 36.9V 37.OV 37.1V 37.2V 37AV Isc 0.065%/°C Normal0 Operating CellTem Temperature4512-C Short Circuit Current(Isc) 8.46A 8.59A 8.74A 8.87A 9.00A P 9 P • • ® Module Efficiency 14.61% 14.92% 15.23% 15.54% 15.85% Operating Temperatureerature -ao°c-+s °c Performance at Low Irradiance Maximum System Voltage 1000V IEC /600V UL Industry leading performance at low irradiation kMaximum Series Fuse Rating 15A environment +95.5/ module efficiency from an radiance of 1000w/m'to 200w/m' Application Classification ClassA irradiance PP Solar Tolerance 0-+5W (AM 1.5,25"C) Next Generation Solar Module Under Standard Test Conditions(STC)of irradiance of l ODOW/m',spectrum AM 1.5 and cell temperature of 25'C NewEdge,the next generation module designed for multiple Engineering Drawings NOCT CS6P-235PX CS6P-240PX CS6P-245PX CS6P-250PX CS6P-255PX types of mounting systems,offers customers the added Nominal Maximum Power(Pmaz) 170W 174W 178w 181W 185w value of minimal system costs,aesthetic seamless Optimum Operating Voltage(Vmp) 27.2V 27.3V 27AV 27.5V 27.5V appearance,auto groundingand theft resistance. Optimum Operating Current(Imp) 6.27A 6.38A 6.49A 6.60A 6.71A Open Circuit Voltage(Voc) 33.9V 34.OV 34.1V 34.2V 34AV IN The black-framed CS6P-PX is a robust 60 cell solar module Short Circuit Current(Isc) 6.86A 6.96A 7.08A 7.19A 7.29A Under Normal operating Cell Temperature,I rradiance of 800 WIm2,spectrum AM 1.5,ambient temperature 2O'C, incorporating the groundbreaking Zep compatible frame. L The specially designed frame allows for rail-free fast wind speed 1 m/s installation with the industry's most reliable grounding Mechanical Data system.The module uses high efficiency poly-crystalline Cell Type Poly-crystalline 156 x 156mm,2 or 3 Busbars Key Features silicon cells laminated with a white back sheet and framed Cell Arrangement 60(6 x 10) with black anodized aluminum.The black-framed CS6P-PX Dimensions 1638 x 982 x 40mm(64.5 x 38.7 x 1.57in) • Quick and easy to install - dramatically is the perfect choice for customers who are looking for a high Weight 20.5kg(45.2 lbs) reduces installation time quality aesthetic module with lowest system cost. Front cover 3.2mm Tempered glass Frame Material Anodized aluminium alloy • Lower system costs - can cut rooftop Best Quality J-Box IP65,3 diodes installation costs in half Cable 4mm'(IEC)/12AWG(UL),1000mm • 235 quality control points in module production Connectors MC4 or MC4 Comparable • Aesthetic seamless appearance - low profile • EL screening to eliminate product defects Standard Packaging(Modules per Pallet) 24pcs with auto leveling and alignment • Current binning to improve system performance Module Pieces per container(40 ft.Container) 672pcs(40'HO) o • Accredited Salt mist resistant le - • Built-in hyper-bonded grounding system - if it's I-V Curves(CS6P-255PX) mounted,it's grounded Best Warranty Insurance i to ) • Theft resistant hardware • 25 years worldwide coverage s , I • 100%warranty term coverage a . ; sectlonA-A _ 1 • Ultra-low parts count - 3 parts for the mounting • Providing third party bankruptcy rights I ' ' I i 35,0 and grounding system • Non-cancellable -` ° I • Industry first comprehensive warranty insurance by • Immediate coverage ' I j AM Best rated leading insurance companies in the • Insured by 3 world top insurance companies world —La0wm2 ' ' v Comprehensive Certificates I r —* ^= 2 1-'„L • Industry leading plus only power tolerance:0­5W f1.5 0 • IEC 61215,IEC 61730, IEC61701 ED2,UL1703, � e . ., n _ • Backward compatibility with all standard rooftop and CEC Listed,CE and MCS 4'1 1 A - ground mounting systems • IS09001:2008:Quality Management System • ISO/TS16949:2009:The automotive quality "Specifications included inthis datasheetare subject to change without prior notice. • Backed By Our New 10/25 Linear Power Warranty management system Plus our added 25 year insurance coverage • IS01 4001:2004:Standards for Environmental About Canadian Solar management system Canadian Solar Inc. is one of the world's largest solar Canadian Solar was founded in Canada in .2001 and was 100% 00 companies. As a leading vertical) Inte rated successful) listed on NASDAQ Exchange (symbol: CSIQ in 97% • QC080000 HSPM:The Certification for P 9 y-� 9 Y 9 ( Y ) dedValue manufacturer of ingots,wafers,cells,solar modules and November 2006. Canadian Solar has module manufacturing 90r 7,Ad From yyarranty Hazardous Substances Regulations solar systems, Canadian Solar delivers solar power capacity of 2.05GW and cell manufacturing capacity of 1.3GW. ,., • OHSAS 18001:2007 International standards for products of uncompromising quality to worldwide env, � occupational health and safety customers. Canadian Solar's world class team of o% professionals works closely with our customers to s 7 10 is 20 2s REACH Compliance provide them with solutions for all their solar needs. 10 year product warranty on materials and workmanship 25 year linear power output warranty www.canadiansolar.com EN-Rev 10.17 Copyright.2012 Canadian Solar Inc. 1 r•99 solar=oo NJ Solar=ooSolarEdge Power Optimizer \ . Module Add-On for North America Q ,• P300 / P350 / P400 SolarEdge Power Optimizer Module Add-On For North America f� P300 P35el P400 6G-cell cell PV (for PV 72- 96 for 6 -cell PV �,.g"; ,:, '_-, modules) modules) modules). G INPUT P300 / P350 / P400 ,� �:• ;= Rated Input DC Powero� 300 350 400 W _ .. CD Absolute Maximum Input Voltage(Voc at lowest temperature) 48 60 80 Vdc MPPT Operating Range 8-48 8 60 8-80 Vdc " O Maximum Short Circuit Current(Isc) _ 10 Adc Maximum DC Input Current 12.5 Adc Maximum Efficiency 995 .. .._ ... ,.._ % ... Weighted Efficiency... .... .... .... ... .... .... 988. .. %...... Overvoltage Category II OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) fr^^c-s y Maximum Output Current _....-.. ..._..... 15 .. ...... .......... Adc ... © Maximum Output Voltage 60 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) 4,__ ' Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE - EMC arU5 Class B IEC61000 6 2 IEC6100 Safety F C P IEC62109 1(class II safety)UL17410 6 a _.. . 3 RoHS Yes .INSTALLATION SPECIFICATIONS . . ... -. .._ Maximum Allowed System Voltage 1000 Vdc > st^k4 "•.:+E �' ry$,y,� Dimenswns(W xLx H). __ .,_, __, ,,, .... 141 x212 x405/S.SS x834x159. .., mm/in„ s ` Tt $.1°arY�`- n "i' ,";,r '{z•fyf e��: Weight(mcludmg.cables) ._... .._._ .. .... ...... .. .. 950(2.1 ...... ... ... .. gr/Ib... n �' - :> -. � .� a1-. �" �+ i •`i*.r t3 tz S OutP tWInput ire Type/Connector Double Insulae d;Amphenol 1 , F *5.° t, ; # Output Wve Length 0.95/30 1.2/3.9 m/ft e %rtrt. rt ` n'*`", OPeratlng Temperature Range....... .... ..�... ... .. - .L.-40 +85/40 +185 ... .. ..... C/�F... �`. •. '�` ' ,"' fid`z ' `{ tt„-1 Protecti atlng. .. 5 NEMA4 t ,; y �' `` _ ,,,� •� �` y fr 4yk'�� l r Relative Humidity. ... ... .. ..... ......... 60 100 . �....... .... %..... 8�3A.� �•,,,�•'��,# {gzt, ,+� ��-��,e as�'r9'- ���C f'�er .I PV SYSTEM DESIGN USING A SOLAREDGE SINGLE PHASE THREE PHASE THREE PHASE .INVERTER 208V 480V PV power optimization at the module-level Minimum String Length(Power Optimizers) 8 10 18 — Up to 25%more energy '. Maximum String Length(Power Optimizers) 25 25 50 ...................Le.ng.._.............................................................._..................._............._......................... ........-_.. Maximum Power per String 5250 6000 12750 W .......................................................................... — Superiore efficiency 99.5% .. ...........................................__...............__..........,.....i............. Parallel Strings of Different Lengths or Orientations Yes — Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading ............._....._......_.............................._....................._........_.........._..................._.........._................................. - Flexible system design for maximum space utilization - Fast installation with a single bolt - - Next generation maintenance with module-level monitoring Module-level voltage shutdown for installer and firefighter safety v. '.' �-� - v • • "tk,, `w ,, , .. ; -P 17 a f , - USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.SOlaredge.u5 KYl :1tlrMln a51h+rr E" �r 7FM, y so I a r Single Phase Inverters for North America sola r m p Ak © © v SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ SE7600A US/SE10000A US/SE11400A US d"{ SE3000A-US SE380OA-US SESOOOA-US SE6000A-US SE760OA-US SE1000OA-US SE1140OA-US Y OUTPUT ,. ;1 9" :x1` 9980 @ 208V olarEdge Single Phase Inverters w• Nominal AC Power Output 3000 3800 5000 6000 7600 11400 VA � w t osoo @ zosv For North America . °": w =" .: Max.AC Power Output .. 3300 4150 5400 @ 208V 6000 8350 @ 12000 VA '' <a ,," p 5450 24oV 1.09.5.0.@2.40V AC Output Voltage Min:Nom:Max.* �z 183-208-229 Vac ...... ................. ............... .................. ................. ................. .................. ......:............ ........... SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US ., AC Output Voltage Min.-Nom.-Max.* SE7600A-US/SE10000A-US/SE11400A-US ;f , 21..2...264 Vac AC Frequency Min.-Nom.-Max.*Max.* 59.3 60-60.5(with Hl country setting 57-60-60.5) Hz �. .... . . .. . . .. .. ...... . .. ..... ....... -6 ... ...... .............. ........ Max.Continuous Output Current 12.5 16 24 @ 2OSV 25 32 48 @ 208V 47.5 A 21 @ 240V 42 @ 240V .. .. ... .. .... . .. ... Utility Monitoring,lslandmg Yes GFDl Protection,Country Configurable ........................ .............. ............ ... ........ .......... .. ...................... ........ .. ... .. / pverte�`� � •� "; ._'` ,M.' x Thresholds - INPUT r 1 I d 1 feats x c 3 a Recommended Max.DC Power- 3750 4750 6250 7500 9500 12400 14250 W fc Wartanl`1 ........ .. .... ...... ... .. ....... .... ........ ...... .... . .... ...... . .. ...... ..... . ..... .. ... =�• '. �a ` ; ret SFJ Transformer-less,Ungrounded Yes dr'y.,?;• Max.In ut Volta.e. .......... ..... ................ .............. ................... .............................................. ........ ... .......... .. 500 •..Vdc Nom.DC Input Voltage 325 @ 208V/3. .@ 240V Vdc �u sfr2 t Max.Input Current*** 9.5 13 16.5 @ 208V 18 23 33 @ 208V 34.5 Adc .... ..... ........ .... ........ ... ............. ..... ....... .15.5 @ 240V. .............. .............. ..30.5 @ 240V.. ............. .. .... ... ' r Max.Input ShortCircuit Current 30 45 Adc Iy sad urT ..................... . . .. .... ......... .,, .+ x„,F- �, l a t '. f. .Reverse Polarity Protection............ .. Yes . ........... .... ...... ................. ..... ......... .' ,S ; -c c5'..a' 5 , ........................ ... ... .... ...... e* t,, „ Ground-Fault Isolation Detection.,,, •• .. 600k❑Sensitivity ... .... .... ._. .,, t4r,+'� �S� .w"a,�.i,�f '.r*�i ..Maximum Inverter Efficiency..... ..97.7.. ..98.2.. ..98.3.. ...98.3... ..8s. ..�$. ...98.. ...��. s�'S'a u, : ............................... ........ ............ .... ...... ..... ... .. ... ........ .. ... ........ .. .......... ......... 97.5 @ 208V X97 @ 208V " t ',� rt. ' }: Weighted Efficiency 97.5 98 97.5 97.5 97.5 X�jn r.;J°`7 •, -"` � "y7r".'5�" CEC 98 @ 240V 97.5 @ 240V eNighttime Power Consumption ..... ......... .. . . ...... ...<2.5... ....... .. . ........ ........... ... .. <4...... ..... . . ...... ...W.... T 'fig ADDITIONAL FEATURES Supported CommunicaR5485,RS232,Ethernet,ZlgBee(optional) ... ......................... . ..... .... ..... . ... . . .. ........... ... ............. ... . .-....... Optional7.12� ANSI C12.1 i a STANDARD COMPLIANCE {{ Safety UL1741,UL16998,UL1998,CSA 22.2 II _.,: ... ......... ............................ .......... ... .. ... ..... ... . .......... ...... ....... ..... .... ... ..... Grid Connection Standards IEEE1547 u. Emissions FCC part15 class B :` t r,' _,, •_ �: .� .. .; .� .: -+ INSTALLATION SPECIFICATIONS 3/4"minimum/8-3 AWG , ... ............. 4m.inimu /246AWG .. ... .. . . .... m .............. ....... . .... ....... ... ...... ...... ... ........ ......... DC input conduit size/#of strings/ minimum s 1 ran a 3/4" um/1 2 rings/24-6 AWG 3/4"minimum/1-2 strings/14-6 AWG tm! a r,s - x,T c + .ons with A .. rz 4 5 < " '. Dimen I AC/DC Safety...... ......30 5 x 12.5 x 7./..... .....30.5 x 12.5 x 7.5./..... ................ .... ............. . . .. .... ...In/.. 30.Sx12.5x10.5/775x315x260 Switch(HxWxD)......... .... ... .. ..775x315x172.... ....775x315x191...... ................. ... .. . ._....... .. .mn1 .. ' ht,with AC/DC Safety Switch ......,.51.2/23.2 .54.7/,24.7,. ...... ,.,., 88.4/40.1 _..., _... lb kg .. ...:. .:. Weight ................. ..... . ....... . . Cooling Natural Convection Fans(userreplaceable) ... . .................................... ............. .. . ...................... ... .. .. . .. .... .. ..... . . The best choice for SolarEd a enabled systems "oi5e <25 <50 dBA E g Y ............................ ................................................................... ................ .. . ................. ............. .... ... . I Min:Max.Operating Temperature -13 to+140/-25 to+60(CAN version****-40 to+60) -F/-C , Integrated arc fault protection(Type 1)for NEC 2011 690.11 compliance ; Range................................... ................................ ......................................................................................... ........... Superior efficiency(98%) Protection Rating NEMA 3R 'For other regional settings please contact SolarEdge support. Small,lightweight and easy to install on provided bracket Limited to 125%for locations where the yearly average high temperature is above 77'F/25'C and to 135%for locations where it is below 77'F/25'C. For detailed information,refer to h solar d dfs' iter d uid df - Built-in module-level monitoring `'A higher current source may be used;the inverter willlimit its input current to the values stated. -CAN P/Ns are eligible for the Ontario FIT and micro FIT(micmFIT ext.5E11400A-US-CAN). — Internet connection through Ethernet or Wireless Outdoor and indoor installation Fixed voltage inverter,DC/AC conversion only — Pre-assembled AC/DC Safety Switch for faster installation ( > bt 1 ars` — Optional—revenue grade data,ANSI C12.1 } sWs c USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-ISRAEL # ��' ' ¢ it �Tha' www.solaredge.us � f � f, . r�� ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERIIED VIA A AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONIC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. 1 CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING P01 POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 STRUCTURAL VIEWS LICENSE GENERAL NOTES PV5 THREE LINE DIAGRAM Cutsheets Attached GEN #168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION A ELEC 1136 MR OF THE MA STATE BUILDING CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: ZEP SOLAR AHJ: North Andover REV BY DATE COMMENTS REV A NAME DATE COMMENTS UTILITY: National Grid USA (Massachusetts Electric) CONFlDENTIAL— THE INFORMATION HEREIN JOB NUMBER JB-01 813 41 00 PREMISE OWNER: DESCRIPTION: DESIGN: `�` CONTAINED SHALL NOT USED FOR THE STASONIS, CHRIS STASONIS RESIDENCE Matt Morse ';;solarCity. BENEFIT OF ANYONE EXCEPT SOLAROTY INC.. MOUNTING SYSTEM: �� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 1514 SALEM ST 9.435 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS [MODULES: NORTH ANDOVER MA 01845ORGANIZATION, EXCEPT IN CONNECTION WITH24 St.Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (37) CANADIAN SOLAR # CS6P-255PX PAGE NAME. SHEET: REV DAIS MoribwIgh,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T. (650)638-1028 F: (650)638-1029 PERMISSION of SOLARCITY INC. SOLAREDGE # SE760OA—USOOOSNR2 (978) 685-5929 COVER SHEET PV 1 11/17/2014 (888)-SOL-CITY(765-2489) www.salarcityx PITCH: 25 ARRAY PITCH:25 MP1 AZIMUTH: 138 ARRAY AZIMUTH: 138 MATERIAL: Comp Shingle STORY: 2 Stories �1NCF PITCH: 25 ARRAY PITCH:25 MP2 AZIMUTH:318 ARRAY AZIMUTH:318 YQQ AN MATERIAL: Comp Shingle STORY: 2 Stories K PITCH: 40 ARRAY PITCH:40 VIIy MP3 AZIMUTH:228 ARRAY AZIMUTH: 228 No.4 7 r-------------- ------------- ----------- MATERIAL: Comp Shingle STORY: 2 Stories / AL ' / Digital s y Yoo Jin Kim Date: 014.11.17 14:50:29 11 3 -08'00' I I I I B I zdw LEGEND t I AC ' ® (E) UTILITY METER & WARNING LABEL nt House INVERTER W/ INTEGRATED' DC DISCO F 2 & WARNING LABELS 11 - T 1 ]11 pU- O ® lEa3l DC DISCONNECT & WARNING LABELS MPt A © AC DISCONNECT & WARNING LABELS DC JUNCTION/COMBINER BOX & LABELS DISTRIBUTION PANEL & LABELS LC LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER Q STANDOFF LOCATIONS (E)DRIVEWAY CONDUIT RUN ON EXTERIOR CONDUIT RUN 1514 S*m st GATE/FENCE ON INTERIOR Q HEAT PRODUCING VENTS ARE RED F, 1% `I INTERIOR EQUIPMENT IS DASHED L='J SITE PLAN 41 Scale:1/16"= 1'— — — — - - 01' 16' 32' s in 1119 CONFIDENTIAL— THE INFORMATION HEREIN [INVERTER: B NUMBER: JB-01 813 41 O O PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE STASONIS, CHRIS STASONIS RESIDENCE Matt MorseBEN ;So�arCity. NOREFIT OF SHALL ITNBENDI CLEXCEPT ED IN WHOLE ORCINUNTING SYSTEM: 1514 SALEM ST 9.435 KW PV ARRAY ' '" PART TO OTHERS OUTSIDE THE RECIPIENTS omp Mount Type C ORGANIZATION, EXCEPT IN CONNECTION NTH DULES NORTH ANDOVER, MA 01845 THE SALE AND USE OF THE RESPECTIVE 37) CANADIAN SOLAR # CS6P-255PX 24 St.Martin Drive,Building 2,unit 1t SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE Marlborough,MA 01752 a PERMISSION OF SOLARCITY INC. T: (650)638-1028 F: (650)638-1029 OLAREDGE SE7600A-USOOOSNR2 (978) 685-5929 SITE PLAN PV 2 11/17/2014 (888)-SOL—CITY(765-2489) www.Balarolty.aam PV MODULE U1 5/16" BOLT WITH LOCK INSTALLATION ORDER 2x6 SPF#2 (N T(E) & FENDER WASHERS(E) 2x4 LOCATE RAFTER, MARK HOLE S1 ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) (2) SEAL PILOT HOLE WITH POLYURETHANESEALANT. tZEP COMP MOUNT C (E) LBw W ZEP FLASHING C (3) (3) INSERT FLASHING. A SIDE VIEW OF MP1 NTS SISTER UPGRADE INFORMATION: RAFTER UPGRADE INDICATED BY HATCHING (E) COMP. SHINGLE (4) PLACE MOUNT. 1 UPGRADE NOTES: ( )I' �I MPJ X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES 1. CUT AND ADD (N) SISTER AS SHOWN IN THIS SIDE VIEW AND REFERENCED TOP VIEW. (E) ROOF DECKING tl (2) tl (5) INSTALL LAG BOLT WITH LANDSCAPE 64" 24" STAGGERED 2. FASTEN (N) SISTER TO (E) MEMBER W/ SIMPSON SDW 22300 (IF 2—PLY) OR 22458 5/16" DIA STAINLESS (5) SEALING WASHER. PORTRAIT 32" 15" (IF 3—PLY) SDW SCREWS STAGGERED AT 16" O.C. ALONG SPAN AS SPECIFIED, IF STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES ROOF AZI 138 PITCH zs INSTALL LEVELING FOOT WITH RAFTER 2x6 @ 16"OC ARRAY AZI 138 PITCH 2s STORIES:2 WOOD SPLITTING IS SEEN OR HEARD, PRE—DRILL WITH A DRILL BIT. WITH SEALING WASHER (6) C.). 2x8 @16"OC Com shin le ALT. OPTION FOR FULL LENGTH MEMBERS ONLY— FASTEN (N) SIDE MEMBER TO BOLT & WASHERS. (E) RAFTER W/ 10d (IF 2—PLY) OR 16d FROM EACH SIDE (IF 3—PLY) COMMON (2-1/2' EMBED, MIN) NAILS 6" O.C. ALONG SPAN. (E) RAFTER STANDOFF •SISTER ALL RAFTERS ON THIS MP SECTION INTO WHICH THE ARRAY IS LAGGED i S 1 oF�I Y00 JIN (K � m, No.4 T •o M. 1G Digitally i y Yoo Jin Kim SIMPSON SDW 22300 WOOD SCREWS 6" END Date:2014.11.17 14:50:35(E) RAFTER DISTANCE -08'00' (E) WALL OR (N) SISTER MEMBER CENTERED (E) RIDGE BOARD 6" O.C. TYP. (E) 2x6 RAFTER SUPPORT BELOW BETWEEN SUPPORTS OR SUPPORT BELOW 24„ — — � SEE MP SIDE VIEW FOR REQUIRED LENGTH � SIMPSON SDW WOOD SCREWS J (N) 2x6 SIDE MEMBER D1 D1 MIR _ U1 TOP VIEW OF PARTIAL LENGTH SISTER D1 2x6 END FASTENER GROUPING Scale: 3/4"=1'-0" Scale: i"=1'-0" CONFIDENTIAL— THE INFORMATION HEREIN [INER UMBER PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE J B-01813 41 O O BENEFIT OF ANYONE EXCEPT SOLARCITY INC., ING SYSTEM STASONIS, CHRIS STASONIS RESIDENCE Matt Morse • ,SolarCity. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 1514 SALEM ST ''��� PART TO OTHERS OUTSIDE THE RECIPIENTS p Mount Type C 9.435 KW PV ARRAY ►r ORGANIZATION, EXCEPT IN CONNECTION WITH ES: NORTH ANDOVER, MA 01845 THE SALE AND USE OF THE RESPECTIVE ) CANADIAN SOLAR # CS6P-255PX 24 St.Martin Drive,Building 2,Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN ER: PAGE NAME SHEET: REV DATE MarlborouT: (650)638-1028 F:A01752 (650)638-1029 PERMISSION OF SCARCITY INC. AREDGE SE7600A–USOOOSNR2 (978) 685-5929" STRUCTURAL VIEWS PV 3 11/17/2014 (866)—SOL-CITY(765-2489) ww.solarcity.com O 2x6 E '1`� SIN YQO JIN S1 U2 KOL 2Xs SPF2 VI 2'-1• No,4 A S 1 AL Digitally si o Jin Kim Date:201 .11.17 14:50:41 f(E) LBW -O$'00' SIDE VIEW OF MP2 NTS SISTER UPGRADE INFORMATION: RAFTER UPGRADE INDICATED BY HATCHING - 10'-1• B UPGRADE NOTES: (E) LBW MP2 I X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES 1. CUT AND ADD (N) SISTER AS SHOWN IN THIS SIDE VIEW AND REFERENCED TOP VIEW. SIDE VIEW OF MP3 LANDSCAPE 64" 24" 1 1 STAGGERED 2. FASTEN (N) SISTER TO (E) MEMBER W/ SIMPSON SDW 22300 (IF 2-PLY) OR 22458 NTS PORTRAIT 32" 15" (IF 3-PLY) SDW SCREWS STAGGERED AT 16. O.C. ALONG SPAN AS SPECIFIED, IF ROOF AZI 318 PITCH 25 RAFTER 2x6 @ 16"OC STORIES:2 WOOD SPLITTING IS SEEN OR HEARD, PRE-DRILL WITH A k• DRILL BIT. ' ARRAY AZI 318 PITCH zs C.J. 2x8 @16"OC Comp Shingle ALT. OPTION FOR FULL LENGTH MEMBERS ONLY- FASTEN (N) SIDE MEMBER TO MP3 X-SPACING x-CANTILEVER Y-SPACING Y-CANTILEVER NOTES (E) RAFTER W/ 10d (IF 2-PLY) OR 16d FROM EACH SIDE (IF 3-PLY) COMMON LANDSCAPE 64" 24" STAGGERED NAILS AT 6" O.C. ALONG SPAN. PORTRAIT 48" 20" •SISTER ALL RAFTERS ON THIS MP SECTION INTO WHICH THE ARRAY IS LAGGED ROOF AZI 228 PITCH 40 RAFTER 2X10 @ 16"OC ARRAY AZI 228 PITCH 40 STORIES: 2 C.T. 2X10 @16"OC Comp Shingle 6" END SIMPSON SDW 22300 WOOD SCREWS (E) RAFTER DISTANCE (E) WALL OR (N) SISTER MEMBER CENTERED (E) RIDGE BOARDS 6" O.C. TYP.—�' (E) 2x6 RAFTER SUPPORT BELOW BETWEEN SUPPORTS OR SUPPORT BELOW 2 4> 11 It 11 SEE MP SIDE VIEW FOR REQUIRED LENGTII �' SIMPSON SDW WOOD SCREWS (N) 2x6 SIDE MEMBER D2 D2 MIR _ TOP VIEW OF PARTIAL LENGTH SISTER 2x6 END FASTENER GROUPING Scale: 3/4"=1'-0" CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: J B-01813 41 00 BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT USED FOR THE STASONIS, CHRIS STASONIS RESIDENCE Matt Morse 't".;,SolarCity NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 1514 SALEM ST 9.435 KW PV ARRAY ��•" PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St.Martin Drive, Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (37) CANADIAN SOLAR # CS6P-255PX Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEET: REV. DATE T: (650)638-1028 F. (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE # SE760OA—USOOOSNR2 (978) 685-5929 STRUCTURAL VIEWS PV 4 11/17/2014 1 (8118)-SOL-CITY(765-2489) www.solarcitycam GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO TWO (N) GROUND Panel Number:GE Inv 1: DC Ungrounded INV 1 -(1)SOLAREDGE ISE760OA-USOOOSNR? LABEL: A -(37)CANADIAN SOLAR CS6P-255PX GEN #168572 ODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:14089803 Inverter; 7 DOW, 240V, 97.5%d w Unifed Disco and ZB, RGM, AFCI PV Module; 255 234.3W PTC, Black Frame, MC4, ZEP Enabled ELEC 1136 MR Overhead Service Entrance INV 2 Voc: 37.4 Vpmax: 30.2 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL �E 20OA/2P MAIN CIRCUIT BREAKER SolarCity Inverter 1 (E) WIRING CUTLER-HAMMER 20OA/2P Disconnect 5 SOLAREDGE 4 A 1 DC+ ' SE760OA-USOOOSNR2 DC- P 1 and 2: 1x19 (E) LOADS B ------------ -------- -- EGC----------------i-i ' L, 240 r---------- L2 DC+ N DG I 3 2 I 40.A/2P ---- GND ------------------ -------- -EGC/ --- DC, DC+ Fj� - I jAf GEC T N DG Dc- P 2 and 3: 1x1 IGND EGC--- --------- ------------ ---F---- -- EGC-----------------♦� I N I (1)Conduit Kit; 3/4'EMT _J o EGC/GEC I I I I I I TO 120/240V SINGLE PHASE I I UTILITY SERVICE I I I I I I I I I J--l- PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Voc* = MAX VOC AT MIN TEMP POI (1)GE #THQL2140 PV BACKFEED BREAKER R (1)CUTLER-HAMMER #DG222URB /� (1)SdarCity 4 STRING JUNCTION BOX Breaker, 4OA/2P, 2 Spaces v Disconnect; 60A, 24OVac, Non-Fusible, NEMA 3R AC A 2x2 STR�GS, UNFUSED, GROUNDED DC -(2)Ground Rod; 5/8'x 8', Copper _(1)CU (1)CUTLER- AMMER DG100NB Ground�Neutral t; 6D-100A, General Duty(DG) PV07)SOLAREDGEO#P 2NA4AZS PowerBox Optimizer, 30OW, H4, DC to DC, ZEP nd (1)AWG#6, Solid Bare Copper -(1)Ground Rod; 5/8' x 8', Copper (N) ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION NO. 2, ADDITIONAL ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE 1 AWG#8, THWN-2, Black (1)AWG #10, THWN-2, Black Voc* =500 VDC Isc =15 ADC �(2 AWG#10, PV WARE, Black Voc* =500 VDC Isc =15 ADC O (1)AWG#8, THWN-2, Red O (1)AWG 110, THWN-2, Red Vmp =350 VDC Imp=12.94 ADC O low(1)AWG#6, Solid Bare Copper EGC Vmp =350 VDC Imp=13.66 ADC (1)AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp 32 AAC (1)AWG #10, THIN-2,.Green EGC, .. . . . . . . LJJ . . . . . . .-(1)AWG#8,,THIN-2,,Green , . EGC/GEC, (1)Conduit,Kit;.3/4'.EMT. . . . . . .. , . (1)AWG#10, THWN-P, Black Voc* =500 VDC Isc =15 ADC (2)AWG#10, PV WIRE Black Voc* =500 VDC Isc =15 ADC ® (1)AWG #10, THIN-2,Red Vmp =350 VDC Imp=13.66 ADC O (1)AWG#6, Solid Bare Copper EGC Vmp =350 VDC Imp=12.94 ADC (!)AN #10, THWN-2,.Green EGC PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: JB-01 81341 00 STASONIS, CHRIS STASONIS RESIDENCE Matt Morse CONTAINEDDSHALL NOT USED FOR THE �OI � BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 1514 SALEM ST 9.435 KW PV ARRAY WAI • PART OTHERS OUTSIDE THE RECIPIENTS MOOULES: NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH r THE SALE AND USE OF THE RESPECTIVE 1(37) CANADIAN SOLAR # CS6P-255PX 24 St. Martin Drive,Building 2,Unit 11 Marlborou ,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEET: REV DATE T. (650)638-1028 : (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE # SE760OA-USOOOSNR2 (978) 685-5929 THREE LINE DIAGRAM PV 5 11/17/2014 (888)-SOL-CiTY(765-2489) ww.solarcitycom Label Location: Label Location: Label Location: • 0 0 0 •o o (C)(CB) o (pf (AC)(POI) v (DC)(INV) Per Code: ����� Per Code: _ _ Per Code: NEC 690.31.G.3 °o o °0 a 7 NEC 690.17.E - o ° o o- •o•� - NEC 690.35(F) Label Location: oQ�iJQoFiq�G�p - 0 0 0 TO BE USED WHEN o•o ° V -o ° ° • ° INVERTER IS PDCer C de:) m�a •o o ° UNGROUNDED D O NEC 690.14.C.2 Label Location: Label Location: o (POI) (DC)(INV) Per Code: '0 Per Code: o - ° °- NEC 690.64.13.7 -o o19 '° - NEC 690.53 o- Label Location: • o 0 0 � (POI) Label Location: - ° ° Per Code: o (DC)(CB) 00 0 0 ° NEC 690.17.4; NEC 690.54 Per Code: �i,• - • o 0 0o o NEC 690.17(4) 'o • °° o•° ° ° °• IIIA ° aRm Vemulsow, ° o ® -o 0 o• oo �p Label Location: o I\IYr3 (DC) (INV) Label Location: 11�J_ Per Code: �� (D) (POI) •o ° ° °• ° NEC 690.5(C) - 0 0 0 SUV Per Code: NEC 690.64.B.4 0 0 0- • Label Location: Label Location: p (POI) (AC) (POI) ° •o - o - Per Code: (AC):AC Disconnect D p Per Code: NEC 690.64.B.4 (C): Conduit NEC 690.14.C.2 05019 (CB): Combiner Box (D): Distribution Panel — _ (DC):DC Disconnect (IC): Interior Run Conduit --Label-Location:- - — — (INV): Inverter With Integrated DC Disconnect (POI) (LC): Load Center Per Per Code: (M): Utility Meter NEC 690.54 M NEC (POI): Point of Interconnection CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLO �: �3t . s®rt� a IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, SSED. C Label Set '.�-��'SOIaIT EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE �� ®OLOWY SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN-PERMISSION OF SOLARCITY INC. SolarCity SleekMountT"" - Comp SolarCity SleekMountTM - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM modules aesthetics while minimizing roof disruption and * �` ' iO Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and Interlock and grounding devices in system UL listed to UL 2703 Fastener Size Per NDS Section 1.1.3.2 mounting clamps, combined with the addition of array trim and a lower profile all contribute •Interlock and Ground Zep ETL listed to UL 1703 �� �0` "' Q Seal pilot hole with roofing sealant to a more visually appealing s SleekMount as"Grounding and Bonding System" d` pp g stem.y � 0 utilizes Zep Compatible TM modules with •Ground Zep UL and ETL listed to UL 467 as Insert Comp Mount flashing under upperlayer of shingle strengthened frames that attach directly to grounding device 4O Place Comp Mount centered Zep Solar standoffs,effectively eliminating the need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition •Anodized components for corrosion resistance Install lag pursuant to NDS Section 11.1.3 shingles are not required to be cut for this with sealing washer. system, allowing for minimal roof disturbance. •Applicable for vent spanning functions --~" © Secure Leveling Foot to the Comp Mount using machine Screw _ O7 Place module Components ® 5/16"Machine Screw 4 !~ ® ® Leveling Foot _— © Lag Screw 1 Comp Mount ® © Comp Mount Flashing 0 -�►1/� oowvarm ��"�i °SolarCity. °SolarCity. ® January2013 �, W U� LISTED �►1 �nNrnoo ® January 2013 CS6P-235/240/245/250/255PX ea (00 ®r CanadianSolar Electrical Data Black-framed STC CS6P-235P CS6P-240P CS6P-245P CS6P-250PXCS6P-255PX Temperature Characteristics Nominal Maximum Power(Pmax) 235W 24OW 245W 250W 255W 1 2!_ _ z�:. Optimum Operating Voltage(Vmp) 29.8V 29.9V 30.OV 30.1V 30.2V Pmax -0.43%/°C ® ® Optimum Operating Current(Imp) 7.90A 8.03A 8.17A 8.30A 8.43A Temperature Coefficient Voc -0.34%/'C Open Circuit Voltage(Voc) 36.9V 37.OV 37.1V 37.2V 37AV Isc 10.065 WC Short Circuit Current(Isc) 8.46A 8.59A 8.74A 8.87A 9.00A Normal Operating Cell Temperature 45±2'C • • • Module Efficiency 14.61% 14.92% 15.23% 15.54% 15.85% Operating Temperature -40*C—+85°C Performance at Low Irradiance • Maximum System Voltage 1000v(IEC)/600v UL Industry leading performance at low irradiation Maximum Series Fuse Rating 15A environment,+95.5%module efficiency from an n Application Classification ClassA irradiance of 10 O0w/m, to 200w/m' Power Tolerance 0—+5W (AM 1.5,25`C) Next Generation A Solar Module Under Standard Test Conditions(STC)ofirra lance of 1000W/m,s ectrum AM 1.5and cell temperature of 25 'C NewEdge,the next generation module designed for multiple N OCT CS6P_235PX CS6P-240PX CS6P-245PX CS6P_250PX CS6P_ 255PXEngineering Drawings types of mounting systems,offers customers the added Nominal Maximum Power(Pmax) 170W 174W 178W 181W 185W value of minimal system costs,aesthetic seamless Optimum Operating Voltage(Vmp) 27.2V 27.3V 27AV 27.5V 27.5V appearance,auto groundingand theft resistance. optimum Operating Current(Imp) 6.27A 6.38A 6.49A 6.60A 6.71A Open Circuit Voltage(Voc) 33.9V 34.OV 34.1V 34.2V 34AV The black-framed CS6P-PX is a robust 60 cell solar module Short Circuit Current(Isc) 6.86A 6.96A 7.08A 7.19A 7.29A incorporating the groundbreaking Zap compatible frame. under Normal operating Cell Temperature,Irradiance of 800 Wim',spectrum AM 1.5,ambient temperature 201C, The specially designed frame allows for rail-free fast wind speed 1 m/s installation with the industry's most reliable grounding Mechanical Data system.The module uses high efficiency poly-crystalline Cell Type Poly-crystalline 156 x 156mm,2 or 3 Busbars Key Features silicon cells laminated with a white back sheet and framed Cell Arrangement 60(6 x 10) with black anodized aluminum.The black-framed CS6P-PX Dimensions 1638 x 982 x 40mm(64.5 x 38.7 x 1.57in) • Quick and easy to install - dramatically is the perfect choice for customers who are looking for a high Weight 20.5kg(45.2 lbs) reduces installation time quality aesthetic module with lowest system cost. Front Cover 3.2mm Tempered glass Frame Material Anodized aluminium alloy • Lower system costs - can cut rooftop Best Quality J-BOX IP65,3diodes installation costs in half Cable 4mm'(IEC)/12AWG(UL),1000mm • 235 quality control points in module production Connectors MC4 or MC4 Comparable • Aesthetic seamless appearance - low profile • EL screening to eliminate product defects j Standard Packaging(Modules per Pallet) 24pcs with auto leveling and alignment • Current binning to improve system performance Module Pieces per container(40 ft.Container) 672pcs(40'HQ) e • Accredited Salt mist resistant - • Built-in hyper-bonded grounding system - if it's I-V Curves(CS6P-255PX) j • mounted,it's grounded Best Warranty Insurance 40 1 I • Theft resistant hardware 25 years worldwide coverage a • 100%warranty term coverage ° JWIZI. ,, SecuonA-A j • Ultra-low parts count - 3 parts for the mounting • Providing third party bankruptcy rights -' I ' ' 35.0 and grounding system Non-cancellable 1° l ' • • Immediate coverage ' s l Industry first comprehensive warranty insurance by �a AM Best rated leading insurance companies in the Insured by 3 world top insurance companies world 1 22 1Comprehensive CertificatesIndustry leading plus only power tolerance:0- 5W —"Y • IEC 61215,IEC 61730, IEC61701 ED2,UL1703, I—dS` f lt5 40 • Backward compatibility with all standard rooftop and CEC Listed,CE and MCS ground mounting systems • IS09001:2008:Quality Management System • ISO/TS16949:2009:The automotive quality -Specifications included in this dalasheet are subject to change without prior notice. • Backed By Our New 10/25 Linear Power Warranty management system Plus our added 25 year insurance coverage • IS014001:2004:Standards for Environmental About Canadian Solar management system Canadian Solar Inc. is one of the world's largest solar Canadian Solar was founded In Canada in 2001 and was t00% • QC080000 HSPM:The Certification for companies. As a leading vertically-integrated successfully listed on NASDAQ Exchange (symbol: CSIQ) in sT% Added yalue From Hazardous Substances Regulations manufacturer of ingots,wafers,cells,solar modules and November 2006.—Canadian Solar-has module manufacturing eo% � rp Warranty 9 solar systems, Canadian-Solar delivers solar power capacity of 2.05GW and cell manufacturing capacity of 1.3GW. rat - ._ • OHSAS 1800.1-:2007-International standards-for—— — — products of uncompromising quality to worldwide 80% W - occupational health and safety customers. Canadian Solar's world class team of - - - - — 6% — professionals works closely with our customers to - - - 5 to is 20 25 • REACH Compliance provide them with solutions for all their solar needs. t • 10 year product warranty on materials and workmanship x aE :o: 0- CYCIE' •25 year linear power output warranty www.canadiansolar.com EN-Rev 10.17 Copyright o 2012 Canadian Solar Inc. L solar=oo solar " o o SolarEdge Power Optimizer Module Add-On for North America t P300 / P350 / P400 SolarEdge Power Optimizer ' _ s°w P300 P350 P400 Module Add-On For North America tl,��. (for6D PV (for 72-cell PV (for 96cell PV ] 'stF .J f N +J• modules) modules) modules) P300 / P350 / P400 ° '"PUT "�,t ;'_ ''` '' Ra[ed Input DC Power('' 300 350 400 W „{ •s e � "; Absolute Maximum Input Voltage(Vo temperature) 48 60.. ... 80 Vdc ,. r y$ - .i ,mss , q - MPPT Operating Range 8-48 _ 8-60 _ 8-80 Vdc_ 't• `k"' ", ,,•,.. _.© �. ,:-R,•', Maximum Short Circwt Curren[(Isc) c 10 _Adc at lowest t to Maximum DC Input Current _.. .. .. ,.,.. 12,5 ... ................ Adc_ Maximum Efficiencyyo Weighted Efficiency .. .. .. .. ... .. .. ........._. ...98.8 ... ... ....... .. ....... ... .. ... .%..... a .. .. .. .. . .. .. Overvoltage Category II OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) Maximum Output Current15 Adc @r•. q'jhj ®� �x .......... ........ ........... ......... .......... _...... .... ........ .. x it Maximum Output Voltage 60 Vdc .OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc r�z .STANDARD COMPLIANCE EMC FCC Part15 Class B,IEC61000-6-2,IEC61000 6 3 Vfp`a" gel''` tt+ t�i t �k :• Safety ..... .... .._ ... .. IEC6210911dass 1l safetY),,UL1741 .... ..... a {` .. .......... .. .._.. _. Yh.' t}•2 �s�tt•.. dh#' ks;.. RoHS .. ... .... Yes .. .INSTALLATION SPECIFICATIONS ` 16 �r Maximum Allowed System Voltage1. 1000 Vdc by Dimensions(WxLz H).. ......... ..... .. 141x212 x405/S.SS x834x 1.59 .... mm/in, ;�a t Weight(including cables) .. .. .. _.. 950/2.1 .. .. ._ gr./lb s 7,k •x. ... _. 1t e A Input Connector .. .. .. MC4/Amphenol/Tyco _,. .., ,. '{ � Output Wire Type Connector Double Insulated:Amphenol �}� k, fi,r' ' Output Wue Length 0.9S/30 1.2/3.9 m/ft • .i="'r` {+' '' 3t n Operating Temperature Ran a -40 +85/-40.-+185 ._.� Protection Raring .. ... ...,. ... .. r' :';,afl ..., .r5s.u' "' fr *yt+Q,,° 1' i{'�Yt'� �.7":.• "n:me nca�.oimomo.a�io mm�i�m�prosxno�nm�ao«mmw�a. P65 NEMA4 'N_ ... ....... .% . .. .... . .... rys v ' PV SYSTEM DESIGN USING A SOLAREDGE THREE PHASE THREE PHASE SINGLE PHASE .INVERTER 208V 480V PV power optimization at the module-level I Minimum String Length(Power Optimizers) 8 10 18 ..... . — Up to 25%more energy Maximum String Length Optimizers)....................................25...,..,.,..,. 25....._.., - Superior efficiency(99.5%) Maximum Power per String 5250 6000 12750 W 1 Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading (� Parallel strings of Different Lengths or Orientations ves — Flexible system design for maximum space utilization — Fast installation with a single bolt - - Next generation maintenance with module-level monitoring s — Module-level voltage shutdown for installer and firefighter safety USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us `6'�''M�'rrY wntnhi in.'tn�prF� riF+ld+-� 6 1i+4 may, �ris+"d;4L , so I a r Single Phase Inverters for North America s o I a r eXo -.. p o O O SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US SE7600A-US/SE10000A-US/SEl1400A-US SE3000A-US SE380OA-US SE5000A-US SE6000A-US SE7600A-US SE10000A-US SE1140OA-US yt ur; 22, OUTPUT SolarEdua Single Phase Inverters 0000 240V J J � �. y, 0 : c Nominal AC Power Output 3000 3800 5000 6000 7600 11400 VA ............ Xr 5400 @ 208V 10800 @ 208V For North America Q rI^ f Max.AC Power Output 3300 4150 5.45.0.@.240V 6000 8350 10950 @240V 12000 VA IV L 11 1 e 1 c ,„ ............... ........ ... .. . arra .. . �=' •,r � "' "� ' v" AC Output Voltage Min.-Nom.-Max.* SE3000A-US/SE3800A-US/SE5000A-US/SE6000A-US/ >:_ ,' ' 4, s. 183 208-229Vac .. ............ ........... .... ........ ............ ..... ...... .......... ........•..... ......... .. arra arra . .. . .. arra arra arra . AC Output Voltage Min:Nom:Max.* SE760OA-US/SE1000OA-US/SE1140OA-US u., 211 240-264 Vac ................ ........I...... . . ... .. .. . ... .. ......... ..... ... .... .. . ........... ................ .. AC Frequency Min.-Nom.-Max.* 59.3-60 60.5(with HI country settin 57 60 60.5) Hz ........................................... ..... ... .......... 8....'....: . . . arra.. .............. ...... ���24 @ 208V � 48 @ 208V��� ¢ Max.Continuous Output Current 12.5 16 25 32 47.5 A ........................................... .............. ..... ....... I. 21 @.240V. Iarra.. arra ........ . .. ...42 @ 24oV... .......... .. ........... GFI .. .... ..... ................ ........ .................................................1....................... ...... ............................ ..A.. Utility Monitoring,Islanding ,^ A, Protection,Country Configurable Yes Thresholds 5 INPUT i - 12 2 ( feats €� �, tc4, .��• ��+#��� � � „3'"�c'� 'a*-� Recommended Max.DC Power arra .-m ,,_ N� �zaR. �,ear c m 3750 4750 6250 7500 9500 12400 14250 W IWaga0�1 ik. '` y •'�' e 'fbr: Sk `3y „* (STC) .. .. .... .... ... ...... ... ........ .... .. ........ ..... ........ ... .. arra.. ..... . ... . i •, "f +a''3„�.aa. �, p e ..__ x9 k�,_:: Transformer less,Ungrounded rt. ..Yes ... o '"ia p r . .. ........ ....... ...................... ................ .......... . .........arra.............. ................ ... .................... . z'r~ -.t arra arra Vara Max,Input Voltage................... ........................ ............ .... ....500... .. ..... ...................... ................... ...Vdc... •r r, arra.. „ 1�, x + +'�F "t ;,eh' I L t v -�ar' - 'r Nom.DC Input Voltage 325 @ 208V.350 @ 240V Vdc i Max. rr n 5 @ 208V I ..33 @ 208V c Input CLI tax.... ... 15.5 @ 240V . ..30.5 @ 240V.. ................ Ad. ... + a�fu­a z,'-t F'r:.' 5 x";*t n •v �• '§k",y' s ........ . . .. . . ..... ....... ..... . arra ........ ...... ....... ............. ... ... .,,,« �:" >vz Max.Input ShortClrcmt Current 30 I 45 Adc r y 9 5 13 18 23 _ arra. arra .. �{ � . � p� ,b� t` arra... .. arra .......... arra... ............ .. arra ... ............. arra... arra... . arra. .. .................. . .......... .... ........... '� _.}ri",C^'."��iSl`-,� "t "„y� xa <' t ° Reverse-Polarity Protection .......... ....................... ...... .. .. ..Yes..... ....................... .......................... .......... x r .. n ... .... ... Ground Fa... ...lation Detection 6001u15ensitivity ....... .. arra. .. .............. .. .. arra.. ... arra. arra .. .. .. arra. x # h -.3,i, .,tr,i, v sx z " Maximum inverter Efficiency 97.7.... ...98:2... 98.3 .. ...98.3.... .....98.... ... 98.. ......98...... ...... �` �w '�� i `^ r �' fll;•;q.,, ............................. ... ... arra .. ..97.5 .. CEC Weighted Efficiency 97.5 . 98 97.5 97.5 97.5 % T 98 @ 240V 97.5 @ 240V,. .,,.... ., arra .. arra. arra ............... ...... ...... ... . .............. ... . .. arra. ar ra .... ......... ... arra 4 Nighttime Power Consumption y� y ADDITIONAL FEATURES i -•- x;'E � "` �" r Supported Communication Interfaces 5 R5485,RS232,Ethernet,2ig8ee(optional) arra arra. arra.. .... ....... ......... ...... . . . .. . .... . .............. Revenue Grade Data,ANSI C12.1 Optional i r t` rSTANDARD COMPLIANCE '. Safety........... .... ...... .. arra arra.. ............. ........ ............ arr a.. 99.. UL19 ................. ... ....arra ...... ... .. . .. ......... '��. z Grid Connection.Standards.. ....... .. ___......... ..... .................. L16IEEE154798 arra . ............. .................. ......... UL1741,U ,CSA 22.2 Emissions FCC part15 class 8 - 4 3/4"minimum/24-6 AWG 3/4"minimum/8-3 AWG I INSTALLATION SPECIFICATIONS -. r- A.output conduit size AWG range _............... ........................ .. . . ..._.... ......... ................. ..... . ......... .. ......... • w ' .��:` •. DC Input conduitsize/#of strings/ `' - '� :,: ,, : .,� - 3/4"minimum/1-2 strings/24-6 AWG 3/4"minimum/1-2 strings/14-6 AWG AWG ran e , >>;. .'z. _� .„r,. '-. Dimensions with AC/DC Safety 30.5 x 12.5 x 7/ 30.5 It 12.5 x Z5/ in/ k. -- r` 30.5x12.5x10.5/775x315x260 !}i Switch(HxWxO) 775 x 315 x 172 775 x 315 x 191 mm '.' Weight with AC/DC Safety Switch 51.2/23.2 547/24.788.4/40.1 .._..,. .. Ib/.kg,., ............................. ..... ....... ................................ .................................. ............................... . arra. .. .... Cooling Natural Convection Fans(user replaceable) arra.. .................................. . .......... ........... ............. . .... ...................I....... .. .. . .. The best choice for SolarEd a enabled systems Noise <2s <so deA g Y Min.-Max.Operating Temperature -13 to+140/-25 to+60(CAN version****-40 to+60) -F/'C Integrated arc fault protection(Type 1)for NEC 2011690.11 compliance Range ........... Superior efficiency(98%) Protection Rating NEMA 3R Ed .......................................................................................................................... ........... •For other regional set hngs please contact SolarEdge support. Small,lightweight and easy to install on provided bracket Limited to 125%for loranonswhere the yearly average high temperature is above n•Fns•Cand tol3s%forloeanonswhere itis below 7rF/25-C. For detailed information,refer to htto//www sglaredee us/tiles/odfs/inverter do oversixing euide.,df Built-In module-level monitoring •A higher current source maybe used;,,.inverterwilllimit itsinput current to thevalues stated. ••CAN P/Ns are eligible for the Ontario FIT and micmFIT(micronT exc.SE31400A-US-CAN). Internet connection through Ethernet or Wireless Outdoor and indoor installation Fixed voltage inverter,DC/AC conversion only - Pre-assembled AC/-0C Safety Switch for faster installation — Optional—revenue grade data,ANSI C12.1 r slxtsa=� , © 3t �I +3d "r } j . USA GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-ISRAEL www.solaredge.usa - B � aFbp 'fib F r r � a6N ��"`� ^• � ��'i z