Building Permit #744-16 - 152 WAVERLY ROAD 12/18/2015
1 J "7111 I BUILDING PERMIT A�.1 TOWN OF NORTH ANDOVER s APPLICATION FOR PLAN EXAMINATION _ 7k 1. Permit No#: Date Received 7�A�RATED Pea'��5 SsgcHuss Date Issued: C I ORTANT: Applicant must complete all items on this page LOCATIN Machines-Shop pillage dye `�o : �i TYPE OF IMPROVEMENT PROPOSED USE Residential Non- Residential ❑ New Building ❑ One family ❑Addition ❑ Two or more family ❑ Industrial ❑Alteration No. of units: ❑ Commercial ❑ Repair, replacement ❑Assessory Bldg ❑ Others: ❑ Demolition ❑ Other 1® Septi ®1Nell i(]Floodplain I 1Netlan I( W�ateyshed ®st�fct Water/Sewer i El�l DESCRIPTION OF WORK TO BE PERFORMED: �nS111l S010-Y 2MMIS_Co tC4 0k -e iWSYV, air -fi b Y5 mA'td awk 1u1- 3 K Identification- Please Type or Print Clearly OWNER: Name: Car 11j n CJ1n&_rn v>i Phone: 6Q Address: Contrac�tor�Noma : 1. _. ? ._s1Z;_�fPh ailRl�� �1 Q es -- ��- rA�tldre s �� �1 �_ , Su,`ervsor s Construction Lac seg �`-' l `qpm- ►ti- i �x .� d `.gip 1 IExp� ®ate: - E—n Home Irnroue_me.,ntLense; � � �1.�:.. IExp.. Date � _ 17 J ARCHITECT/ENGINEER Phone: Address: Reg. No. FEE SCHEDULE.BULDING PERMIT.$12.00 PER$9000.00 OF THE TOTAL ESTIMATED COST BASED ON$925.00 PER S.F. .z Y` Total Project Cost: $ � i 6Dib FEE: $ • ��2 2-- Check No.. � Receipt No.: NOTE: Persons contracting with unregistered contractors do not have acce o the gua my fund Signature?oftAgent/,O er .-Si of�contractor M ,fi; ," 1� �,✓ 4" I Plans Submitted ❑ Plans Waived.[] Certified Plot Plan ❑ Stamped Plans ❑ TYPE OF SEWERAGE DISPOSAL Public Sewer ❑ Tanning/Massage/Body Art ❑ Swimming Pools - ❑ Well ❑ Tobacco Sales ❑ Food Packaging/Sales ❑ Private(septic tank,etc. ❑ Permanent Dumpster on Site ❑ THE FOLLOWING SECTIONS FOR OFFICE USE ONLY INTERDEPARTMENTAL SIGN OFF - U FORM PLANNING & DEVELOPMENT Reviewed On Signature_ COMMENTS CONSERVATION Reviewed on Siqnature COMMENTS WEALTH Reviewed on Siqnature COMMENTS r Zoning Board of Appeals:Variance, Petition No: Zoning Decision/receipt submitted yes C Planning Board Decision: Comments Conservation Decision: Comments Water& Sewer Connection/Signature& Date Driveway Permit DPW Town Engineer: Signature: Located 384 Osgood Street FIRE DEPARaTMENTaTern ®u SL� 4pmpster�onsite. .Ys Loeatetl at.124Main Streete r F, re Department signet a%dale ' � a y ,,_., .....-_..�.vi..,.,i-_.._.:,.w..�.ss!—..a.-.�... .S'est.•a..r�c�,�.,:f...�.'+�e�.,.:�w.. �'_ .�__..� .;. �..��, i Dimension Number of Stories: Total square feet of floor area, based on Exterior dimensions. Total land area, sq. ft.: ELECTRICAL: Movement of Meter location, avast or service drop requires approval of Electrical Inspector Yes No DANGER ZONE LITERATURE: Yes No MGL Chapter 166 Section 21A—F and G min.$100-$1000 fine NOTES and DATA— (Fordepaartment use) i ® Notified for pickup Call Email Date Time Contact Name - Doc.Building Permit Revised 2014 �I Building Department The following is a list of the required forms to be filled out for the appropriate permit to be obtained. Roofing, Siding, Interior Rehabilitation Permits ❑ Building Permit Application o Workers Comp Affidavit ❑ Photo Copy Of H.I.C. And/Or C.S.L. Licenses ❑ Copy of Contract ❑ Floor Plan Or Proposed Interior Work o Engineering Affidavits for Engineered products J®TE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit + Addition Or Decks o Building Permit Application o Certified Surveyed Plot Plan o Workers Comp Affidavit o Photo Copy of H.I.C. And C.S.L. Licenses a Copy Of Contract ❑ Floor/Cross Section/Elevation Plan Of Proposed Work With Sprinkler Plan And Hydraulic Calculations (If Applicable) o Mass check Energy Compliance Report (If Applicable) o Engineering Affidavits for Engineered products TOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit New Construction (Single and Two Family) o Building Permit Application o Certified Proposed Plot Plan o Photo of H.I.C. And C.S.L. Licenses o Workers Comp Affidavit o Two Sets of Building Plans (One To Be Returned) to Include Sprinkler Plan And Hydraulic Calculations (If Applicable) o Copy of Contract o Mass check Energy Compliance Report o Engineering Affidavits for Engineered products 10TE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg. Permit In all cases if a variance or special permit was required the Town Clerks office must stamp the decision from the Board of Appeals that the appeal period is over. The applicant must then get this recorded at the Registry of Deeds. One copy and proof of recording must be submitted with the building application Doc:Building Permit Revised 2014 Location No. 01 Date 4 � v . - TOWN OF NORTH ANDOVER Certificate of Occupancy $ a r Building/Frame Permit Fee $ Foundation Permit Fee $ Other Permit Fee $ TOTAL $ Check# 29840 Building Inspector !r 1 NORT1y ve" '* 0 :yr ti No. Z h ver, Mas 111• 1W, 42b16 coce"C"tw1cw yT �TS R�4TE0 I�P��.�y U BOARD OF HEALTH Food/Kitchen PER T D Septic System f% L THIS CERTIFIES THAT ........... R.9 BUILDING INSPECTOR .�G .,p.�.......... ...................................... �. Foundation 155zhas permission to erect .......................... buildings on .... .. .... ............�................... Rough V.0 to be occupied as ... .... QJ .... ... .+.........:....�. .. ......................... Chimney provided that the person accepting this permit shall in every respect conform to the terms of the application Final on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection,Alteration and Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR Rough VIOLATION of the Zoning or Building Regulations Voids this Permit. Final PERMIT EXPIRES IN-fi MONT S ELECTRICAL INSPECTOR UNLESS CONSTRUCXWWkTA S Rough - Service ............ ............................................................ Final BUILDING INSPECTOR GAS INSPECTOR Occupancy Permit Required to Occupy Building Rough Display in a Conspicuous Place on the Premises — Do Not Remove Final No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. Burner Street No. Smoke Det. North Andover Board of Assessors Public Access Page I of I ,40RT#1North Andover Board of Ass4,�;�,sqrs C S L4`'Property Record Card Click Seal To Return Parcel ID :210/014.0-0051-0000.0 FY:2015 Community :North Andover SKETCH PHOTO Click on Sketch to Enlarge Click on Photo to Enlarge Search for Parcels Search for Sales Summary Residence Detached Structure Condo 152 WAVERLEY ROAD Commercial Location: 152-154 WAVERLY ROAD Owner Name: CHAMPY,BARRY CRAMPY,CAROLYN Owner Address: 152 WAVERLY ROAD City: NORTH ANDOVER State: MA Zip: 01845 Neighborhood:5-5 Land Area: 0.17 acres Use Code: 104-TWO-FAM-RES Total Finished Area: 2476 sgft ASSESSMENTS CURRENT YEAR PREVIOUS YEAR Total Value: 311,300 277,600 Building Value: 155,200 124,900 Land Value: 156,100 152,700 Market Land Value: 156,100 Chapter Land Value: I LATEST SALE Sale Price: 250,000 Sale Date: 12/01/2005 Arms Length Sale Code: G-NO-PARTIAL Grantor: CAMPIONE, DOROTHY Cert Doc: Book: 9921 Page: 332 1 http://csc-ma.us/PROPAPP/di splay.do?linkld=261512 5&town=NandoverPubAcc 12/18/2015 Version#53.6-TBD PIL ."Sdarcfty. .r December 15, 2015 RE: CERTIFICATION LETTER ' Project/Job # 0182682 q JASON WIL [AM Project Address: Champy Residence Re 0 TDMAN 152 Waverly Rd ' -4 North Andover, MA 01845 0 STRUCTURAt Cn No.51554 AH] North Andover SC Office Wilmington �•` fiG'PSTt�� Design Criteria: NAL 15/2015 -Applicable Codes = MA Res. Code,8th Edition,ASCE 7-05,and 2005 NDS - Risk Category = II -Wind Speed = 100 mph, Exposure Category C -Ground Snow Load = 50 psf - MPI: Roof DL= 15 psf, Roof LL/SL= 30 psf(Non-PV Areas), Roof LL/SL= 16.5 psf(PV Areas) - MP2: Roof DL= 15 psf, Roof LL/SL= 30 psf(Non-PV Areas), Roof LL/SL= 16.5 psf(PV Areas) Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.33365 < 0.4g and Seismic Design Category(SDC) = C < D To Whom It May Concern, A jobsite survey of the existing framing system of the address indicated above was performed by a site survey team from SolarCity. Structural evaluation was based on site observations and the design criteria listed above. Based on this evaluationI certify that the existing structure directly supporting the PV system is adequate to withstand all loading indicated in the design criteria above based on the requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally, I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the ASCE 7 standards for loading. The PV assembly hardware specifications are contained in the plans submitted for approval. Additionally a summary of the structural review is provided in the results summary tables on the following page. i Digitally signed by Jason Toman Date:2015.12.15 21:15:31 -07'00' 3055 Clearview Way San Mateo,CA 94402 T(650)638-1028 (888)SOL-CITY F(650)638-1029 solarcity.com rX1r i 27CF:.¢...'Yi'.Ca'.CL a Ld Version#53.6-TBD ' PIL oarC*Pt HARDWARE DESIGN AND STRUCTURAL ANALYSIS RESULTS SUMMARY TABLES Landscape Hardware-Landscape Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MP3 72" 24" 39" NA Staggered 71.2% MP2 72" 24" 39" NA Staggered 71.2% Portrait Hardware-Portrait Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MP3 48" 20" 65" NA Staggered 78.9% MP2 48" 20" 65" NA Staggered 78.9% Structure Mounting Plane Framing Qualification Results Type Spacing Pitch Member Evaluation Results MP1 Finished Attic @ 24 in.O.C. 420 Member Impact Check OK MP2 Finished Attic @ 24 in.O.C. 420 Member Impact Check OK Refer to the submitted drawings for details of information collected during a site survey. All member analysis and/or evaluation is based on framing information gathered on site.The existing gravity and lateral load carrying members were evaluated in accordance with the IBC and the IEBC. 3055 Clearview Way San Mateo,CA 94402 T(650)638-1028 (888)SOL-CITY F(650)638-1029 solarcity.com M`,Ft_', ;z !"'M i., N.litir .. OR CCs STRUCTURE ANALYSIS LOADING SUMMARY ANDWMEMBER CHECK- MPI w Member Properties Summary MPI Horizontal Member Spans Rafter Properties Overhang 0.99 It Actual W 1.88" Roof Systern Pro ernes San 1 6.01 It Actual D 5.00" Number of Spans(w/o Overhan 2 San 2 6.70 ft Nominal No Roofing Material Com Roof San 3 A 9.38 in.^2 Re-Roof No Span 4 S. 7.81 in A3 Plywood Sheathing Yes San S I 19,53 in.^4 Board Sheathing Solid-Sheathing Total Rake Span 18.44 ft TL Defl'n Limit 180 Vaulted Ceiling Yes PV'1 Start 0.67 It Wood Species SPF Ceiling Finish 1/2"Gypsum Board PV 1 End 17.25 ft Wood Grade #2 Rafter Sloe 420 PV 2 Start Fb 875 psi Rafter Spacing 24"O.C. PV 2 End F„ 135 psi Top Lat Bracing Full PV 3 Start E 1400000 psi Bot Lat Bracing t Full PV 3 End E,„;,, 510000 psi Member Loading Summa Roof Pitch 11/12 Initial Pitch Adjust Non-PV Areas PV Areas Roof Dead Load DL 15.0 psf x 1.35 20.2 psf 20.2 psf PV Dead Load PV-DL 3.0 psf x 1.35 4.0 psf Roof Live Load RLL 20.0 psf x 0.65 13.0 psf Live/Snow Load LL/SL 1,2 50,0 psf x 0.6 1 x 0.33 30.0 pisf 16.5 psf Total Load(Governing LC I TL 1 50.2 psf 1 40.7 psf Notes: 1. ps=Cs*pf;Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf=0.7(Ce)(CJ(Is)p9; Ce=0.9,Ct=1.1,I5=1.0 Member Design Summa (per NDS Governing Load Comb CD CL + Cl. CIF Cr D+S _ 1.15 1.00 1 1.00 1 1.4 1.15 Member Anal sis Results Summary Governing Analysis I Pre-PV Demand I lPost-PVD;martdlNet Im act I Result Gravity Loading Check -771 psi -620 psi 0.80 Pass ;CALCULATION OF DESGNrWIND LOADS MP1_ Mountina Plane Information Roofing MaterialComp Roof .... .._ PV System Type solarCity SleekMountT"' Spanning Vents No Standoff Attachment Hardware Comp Mount Type C Roof Slope 420 Rafter Spacing 24"O.C. Framing Type Direction Y-Y Rafters Purlin,Spacing X-X Purlins Only NA Tile Reveal Tile Roofs Only NA Tile Attachment System Tile Roofs Only - NA .Standing Seam/Trap Spacing SM Seam Only NA Wind_Design Criteria Wind Design Code ASCE 7-05 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 100 mph Fig. 6-1 Exposure Category C _ Section 6.5.6.3 Roof Style _ Gable Roof Fig.6-11B/C/D-14A/B Mean Roof Height h 25 ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.95 Table 6-3 Topographic Factor Krt 1.00 Section 6.5.7 Wind Directionality Factor _-_ Ka_._ _--_-_ 0.85 Table 6-4 Im ortance Factor I 1.0 Table 6-1 Velocity Pressure qh qh = 0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 20.6 psf Wind Pressure Ext. Pressure Coefficient U GC u -0.95 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient Down GC, 0.88 Fig,6-11B/C/D-14A/B Design Wind Pressure p p = qh(GC ) Equation 6-22 Wind Pressure U „ , -19.6 psf Wind Pressure Down Pfdow,l 18.0 sf rALLOWABLEST ANDOFF SPACINGS X-Direction Y-Direction; Max Allowable Standoff,Spacin9 _ Landscape 72" 39" Max Allowable Cantilever _ Landscape 24" 'NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 20 sf PV_Assembly Dead Load W-PV3.6 psf Net Wind Uplift at Standoff T-actual m _ -356 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 71.2% X-Direction Y Direction Max Allowable Standoff Spacing_ _ Portrait _ 48" 65 Max Allowable Cantilever Portrait Standoff Configuration Portrait Staggered Max Standoff Tributary Area n Trib _ 22 sf. PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -395 lbs Uplift Capacity.of Standoff T-allow 500 lbs Standoff Demand/CapacityDCR 78.9% i STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK - MP2 Member Properties Summary MP2 Horizontal Member Spans Rafter Pro"'erties Overhang 0.99 ft Actual W 1.88" Roof System Proernes San 1 8.99 ft Actual D 5.00" Number of Spans(w/o Overhang) 2 San 2 3.72 ft Nominal No Roofina Material Comp Roof San 3 A 9.38 in.^2 Re-Roof No Span 4 S. 7.81 in.^3 Plywood Sheathing Yes San 5 I19.53 in.^4 Board SheathingSolid-SheathingTotal Rake Span 18.44 ft TL Deflt Limit 180 Vaulted Ceiling Yes PV 1 Start 10.75 ft Wood Species SPF Ceiling Finish 1/2"Gypsum Board PV 1 End 17.42 ft Wood Grade #2 Rafter Slope 420 PV 2 Start Fb 875 psi Rafter S acin 24"O.C. PV 2 End F„ 135 psi Top tat Bracing Full PV 3 Start E 1400000 psi Bot Lat Bracing Full PV 3 End Emi„ 510000 psi Member Loading mary Roof Pitch 11112 Initial Pitch Adjust Non-PV Areas PV Areas Roof Dead Load DL 15.0 psf x 1.35 20.2 psf 20.2 psf PV Dead Load PV-DL 3.0 psf x 1.35 4.0 psf Roof Live Load RLL 20.0 psf x 0.65 13.0 psf Live/Snow Load LL SL1,2 50.0 psf x 0.6 1 x 0.33 30.0 psf 16.5 psf Total Load(Governing`LC TL I 50:2 psf 1 40.7 psf Notes: 1. ps=Cs*pf;Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf=0.7(Ce)(Ct)(IS)pg; C.=0.9,Ct=1.1, I5=1.0 Member Design Summa' er NDS Governing'Load Comb CD CL + CL - CF Cr D+S 1.15 1.00 1 1.00 1 1.4 1.15 Member Anal sis Results Summary Governing Analysis Pre-PV Demand I Post-PV Demand Net Impact Result Gravity Loading Check -1158 psi -1119 psi 0.97 Pass .. .s iL CALCULATION OFDESIGIV WIND LOAD-9--MPI Mounting Plane Information Roofing_Material Comp Roof_ PV System Type sola SleekMount;'" an Spning Vents _ _ Standoff Attachment Hardware ry _ Comp Mount Type G Roof Slope 420 Rafter Spacing 24"O.C. Framing Type Direction Y-Y Rafters Purlin Spacing - X-X Purlins Only NA Tile Reveal Tile Roofs Only NA __. __ . ._ __- -- --------.-. _ ....- Tile Attachment System Tile Roofs Only NA` ,Standing Seam/Trap Spacing SM Seam Only NA Wind Design Criteria Wind Design Code _ ASCE 7-05 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 100 C Section 6.5.6.3 mph Fig. 6-1 _ Exposure Category _ _ _- Roof StyleGable Roof Fig.6-11B/C/D-14A/B Mean Roof Height h 25 ft _ u Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.95 Table 6-3 Topographic Factor K 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 importance Factor I 1.0 Table 6-1 Velocity Pressure qh qh =0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 20.6 psf Wind Pressure Ext. Pressure Coefficient U GC -0.95 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient Down GC (Down) 0.88 Fig.6-118/C/D-14A/B Design Wind Pressure p p =qh(GC) Equation 6-22 Wind Pressure U -19.6 psf Wind Pressure Down 18.0 sf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing.___ Landscape 72" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 20 sf PV Assembly Dead Load_ _ _ _ W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -356-lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand Ca a city D C R 71.2% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait48" 65" Max Allowable Cantilever Portrait w 20j .... .. - NA Standoff Configuration Portrait Staggered Max Standoff Tributary,Area _ Trib _22 sf PV_AssembN Dead Load W-PV 3.0 Psf .... .._. ... . _ Net Wind Uplift at StandoffT actual -395 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand Ca aci DGR 78.9% DocuSign Envelope ID:74C10A26-C7A3-4770-9530-E5CCD2760527 SolarCity I PPA Customer Name and Address Installation Location Date Carolyn Champy 152 Waverly Rd 9/7/2015 152 Waverly Rd North Andover,MA 01845 North Andover,MA 01845 Here are the key terms of your Power Purchase Agreement UU System installation cost Electricity rate ��kWh Agreement TUm CInitial here Initial here_..._...._..........,._„_ ff D The SolarCity Promise We guarantee that if you sell your Home,the buyer will qualify to assume your Agreement. ......:.................................................................. Initial here __._..___ •We warrant all of our roofing work. DS •We restore your roof at the end of the Agreement. •We warrant,insure, maintain and repair the System. .................................................................. .......................:..:.::....................:.......................................................:................................ Initial hereK,__ _ •We fix or pay for any damage we may cause to your property. •We provide 24/7 web-enabled monitoring at no additional cost. •The rate you pay us will never increase by more than 2.90%-per year. f •The pricing in this Agreement is valid for 30 days after 9/7/2015. •You are free to cancel any time prior to construction atno charge. C� Your SolarCityPower Purchase Agreement Details g Your Choices at the End of the Initial Options for System Purchase: Amount due at contract signing Term: .At certain times,as specified in $0 •SolarCity will remove the System at no the Agreement,you may Est.amount due at installation cost to you. purchase the System. $0 •You can upgrade to a new System with •These options apply during the 20 the latest solar technology under a new year term of our Agreement and Est.amount due at building inspection contract. not beyond that term. $0 •You may purchase the System from Est.first year production SolarCity for its fair market value as 14,800 kWh specified in the Agreement. •You may renew this Agreement for up to ten(10)years in two(2)five(5)year increments. 3055 Clearview Way,San Mateo, CA 94402 1 888.765.2489 { solarcity.com 1099024 Power Purchase Agreement,version 9.0.3,August 24,2015 SAPC/SEFA Compliant Contractors License MA HIC 168572/EL-1136MR ❑ ❑ Document generated on 9/7/2015 Copyright 2008-2015 SolarCity Corporation,All Rights Reserved T DocuSign Envelope ID:74C10A26-C7A3-4770-9530-E5CCD2760527 23. NOTICE OF RIGHT TO CANCEL. I have read this Power Purchase Agreement and the Exhibits in YOU MAY CANCEL THIS CONTRACT AT ANY TIME PRIOR their entirety and I acknowledge that I have received a TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE complete copy of this Power Purchase Agreement. DATE YOU SIGN THIS CONTRACT. SEE EXHIBIT 1,THE ATTACHED NOTICE OF CANCELLATION FORM FOR AN Customer's Name:Carolyn Champy EXPLANATION OF THIS RIGHT. 24. ADDITIONAL RIGHTS TO CANCEL. Docuslgned by: IN ADDITION TO ANY RIGHTS YOU MAY HAVE TO CANCEL Signature: THIS PPA UNDER SECTION 23,YOU MAY ALSO CANCEL THIS PPA AT NO COST AT ANY TIME PRIOR TO Date: 9/7/2015 COMMENCEMENT OF CONSTRUCTION ON YOUR HOME. 25. Pricing The pricing in this PPA is valid for 30 days after 9/7/2015. If you don't sign this PPA and return it to us on or prior to Customer's Name: 30 days after 9/7/2015,SolarCity reserves the right to reject this PPA unless you agree to our then current pricing. Signature: Date: Power Purchase Agreement SolarCity approved Signature: Lyndon Rive, CEO Date: 9/7/2015 Power Purchase Agreement.version 9.0.3,August 24,2015 1.099024 r ' The Cornmonwedth ofMamachasetts Department of 1hdustr1a1Aceiden1s Office of 1nvesdga&ns 9jl Congress Street,Su to 100 Boston,MA 02114-2017 www mess gov/dia Workers'Compensation Insurance Affidavit:Suildelrs/trontracters/LtcctrichmsMumbers ARRUC21111 Id—OXEMAft Please Print Legibly Nasrie(flusiness(Organizationtindividuai): SolarCity Corp. Addrm: 3055 Clearview Way Cit /S€ategi : San Mateo CA. 94402 Phone#.888-765-2489 P _ Are you an employer?Check the appropriate box: Type of project(req ttireil)_ 1.Elam am a employer with 5,000 4. C] I ant a general contractor and I emplayets(full andfor part-time).* have hired the suis-coahactors 6. E-1 Now construction 2.❑ 1 arts it sole proprietor or partner- listed on the attached sheet. 7. ❑Remodeling ship and have no employees These sub-contractors have g. Demolition working for me in any Capacity, employees and have workers' (No workers' comp. instn'artce camp.ilt5tuanae? 9. ©Building addition required.) 5. �] We are a corporation and its 10.[a Electrioal repairs or additions 3.Q 1 ain a homeowner doing all work officers have exercised their 11,❑Plumbing repairs or additions layboll::L`No workers' comp.. Jigliiof exem do t Per ivivi p 12.❑Roof repairs insurance required,)t c. 152,§1(4),and ova have no employees.(No workers' 13[D Other Solar/PV comp. Insurance required. "Any appikattt that ebecks box B i must also fiR ant the section below showing their tvorkcrs'tmntptxssotion policy information. I Homeowners wha submit this affidavit itrdicaling they are doing all abrk and then hire outsido eantractors must submit a nets atlldovit indicating such. :Contractors that check this box must attached an additional shcut showing the name,of the sub•contmetati and static whether or nor those.entities have employees. free sub-contractors have employees,they must provide their workers'comp policy number. I am an employer that is providing workers'compensation.insurance jar my employees. Below is the policy and job site Information. Insurance Company Name: Zurich American Insurance Company Policy#or Self ins.Lic.#: WC0182015-00 Expiration Date:X9/1/2016 Job Site Address: t SZ V city/state/'Lip: ty-- �n"Q,xmd Attach a eopyof the workers' compeusatio policy declaration page(showing the policy number and explration date}. Failure to secure coverage as required undcr Siction 25A of MGL c. I52 can lead to the imposition of criminal penalties of a fine up to 51,500.00 araVar one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to S250.00•ra day against the violator. Be advised that.a.copy of this statement may be forwarded to the Office of luvestigations of the DIA for insurance coverage verification. I do hereby certy�jjthe pains and penaffles of perjury that tine information proi4ded above is true and correct Si' Atu Date: i l• S Of"iclal use only, Do not iprka ler this area,to b2 cowpletett by city or town okuial. City or Town: Penuit/I:kease l{ Issuing Authority(circle ones 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector S.Plumbing Inspector b.Either Contact Person: Phone#; ACCMVDATEIM4DDmYn, CERTIFICATE OF LIABILITY INSURANCE0811712015 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL.INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endomement(s). PRODUCER CONTACT MARSH RISK& INSURANCE SERVICES PHONE _....._..__.._..._... ... .............. .. . .. ... T FAX --. ._... 345 CALIFORNIA STREET,SUITE 1340 .{A/Cr,A!Ir). ......... ......... .............. CALIFORNIA LICENSE NO.0437153 E-MAIL SAN FRANCISCO,CA 94104 _AP.2.$94"§:. ..... .............. ... ..... .. .............. ........... ........ ......... ........T .........._..........._. Attn:Shannon Soon 415-743.8334 ! stlRERjsjAFFORD!Nc coVBRaaE.. .._ y_.. NAM—*....... ... .. .... .. . .. .............. 998301STND-GAWUE-15.16 INSURER A;Zudch American Insurance Company 16535 _ ._......._........... ... .. -......_.__._. ..... . ... ..........-.. ... .. ..... ......._. INSURED INSURER B:N/A ;NIA SolarCity Corporation . .. ...... ._.. +.. .. ....... 3455 Cleanriew Way _WSURER c.:NIANIA San Mateo,CA 94402 _... ....... ..... ......_............._..... ................_.....+._._. ..... ..... .. ... _wsuRER n!American Zurich Insurance Company +40142 INSURER E INSURER r: COVERAGES CERTIFICATE NUMBER: SEA-002713836.06 REVISION NUMBER:4 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQU3REMENT.TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. _ I ow Y, LTR TYPE OF INSURANCE DOL: BR PO C NUMBER POLICY EFF POLICY EXP LIMITS A X COMMERCIAL GENERAL LIABILITY IGLOO182016-00 49/0112015 `0913112016 EACH OCCURRENCE S 3,040,004 - -� � ... DAMAGE TbIii:NTISD _ +$ CLAIMS-MADE X]OCCUR I PREMISES 1Ea pcfurrence�....*.. . 3,444,444 X Slit:$250,000 MED EXP(Any one person) S5,000 ..... ................._......................... ..... i ,.............. _ ._.... f..., . ._........... ................._........._.. ........... I PERSONAL&ADV... ........ . . .........._.............. .......-600000 INJURY �S 3,000,00 i GEN'L AGGREGATE LIMIT APPLIES PER : i i GENERAL AGGREGATE S X POLICY,.. J£C i LOC I F PRODUCTS•COMPIOP AGG $ 6,000,000 F. .I i :OTHER A '.AUTOMOBILE LIAeIUTY `BAP0182017.00 ;0910112015 0910112016 I E LIMIT $ 5,000,000 ' X !ANY AUTO I BODILY INJURY(Per person) $ -. )C ALL OWNED 'X SCHEDULED .BODILY INJURY(Per accdent){$ ,.. ..i AUTOS r.... AUTOS i.... ......_........ X 'HIRED AUTOS • X AUTOS NONI-OWNED t i�Oant�AlVl%iGE 8 COMPICOLL DED_ $ $5.000 UMBRELLA LIAO OCCUR I OCCURRENCE._OCCU EACR $ ...0........_......R .. ........... .....{. ........ ........... _....... ! EXCESS LIAB CLAIMS MADE' AGGREGATI= $ DED RETENTfON$ ;$ D WORKERSCOMPENSATION WC0162414.00(AOS) 0914112015 091011 16 X PER ;OTH- �AND EMPLOYERS'LIABILITY F._._.y STATVTE. t R....I.... A YIN :WC0182015.00 MA :0910112015 109101/2016 E L EACH IANYPROPRIETORIPARTNERIEXECUTIVE I ACCIDENT S 1,000,000 OFFICER/MEMBER EXCLUDED? �;N I A;� {Mandatory In NH} I PC DEDUCTIBLE:$500,lm0 E.L DISEASE_EA EMPLOYE S 1000,000 If yes.describe under I ._.._.............. .... .__.... .-.... ._.. ........ DE CRIPTION OF OPERATIONS below I E L DISEASE•POLICY LIMIT I S 1.000,000 I I DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(ACORD 101.Additional Romarks Schedule,may be attached It more space Is required) Evidence of insurance. CERTIFICATE 14OLDER CANCELLATION SolarCl'ly Corporation SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 3055CfeapAewWay THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN San Mateo,CA 99402 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE or Marsh Risk&Insurance Services Chadd Marmolejo - '��-- 01888-2014 ACORD CORPORATION. All rights reserved. ACORD 26(2014101) The ACORD name and logo are registered marks of ACORD - Office of Consumer Affairs and Business Regulation 10 Park Plaza - Suite 5170 Boston, Massachusetts 02.116 Home Improvement Contractor Registration Registration: 168572 Type: Supplement Card SOLAR CITY CORPORATION Expiration: 3/8/2017 DAN FONZI 24 ST MARTIN STREET BLD 2UNIT 11 -- - ----- MARLBOROUGH, MA 01752 Update Address and return card.Mark reason for change. r, Address E] Renewal f-� Employment Lost Card LtHrIce of Cousumer Affairs&Business Reguiation License or registration valid for individul use only ,- OME IMPROVEMENT CONTRACTOR before the expiration date. If found return to: Office of Consumer Affairs and Business Regulation Registration: 168572 Type: 10 Park Plaza-Suite 5170 Expiration: 3/8/2017 Supplement Cerd Boston,MA 02116 SOLAR CITY CORPORATION DAN FONZI 3055 CLEARVIEW WAY SAN MATEO,CA 94402 Undersecretary Not valid without signature i . ' .,.-�3�.t`:t'ZC"''3•i,'�f"*t1r►::-4t Oa�i35f'.tC S`.t�'°'z / Poard of Buiktirsg Re--jutattama vnd�--tarzc Zf - f„n.tro.tz+a'+ulzrrzr.fr . Ocense CS-1D1687 VV DANIEL D FON21= 15 XZLLLEY RD WnAONGTON MA 01 , Corrinn�cra�i,ez 08/13/2016 f p7olnyeft9fCC Office of Consumer Affairs and Business Regulation 10 Park Plaza- Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 168572 Type: Supplement Card SOLAR CITY CORPORATION Expiration: 3/812017 ASTRID BLANCO 3055 CLEARVIEW WAY -- SAN MATEO, CA 94402 Update Address and return card.Mark reason for change. SCA t G 20M-0511 t ❑ Address [] Renewal iJ Employment Ej Lost Card X� `1Fcrf�./jlcAlrsc/G W-0Registration: flice of Consumer Affairs&Business Regulation License or registration valid for individul use only OME IMPROVEMENT CONTRACTOR before the expiration date. If found return to: Office of Consumer Affairs and Business Regulation 168572 TYPE"• 10 Park Plaza-Suite 5170 � Expiration: 3/8/2017 Supplement Card Boston,MA 02116 .. SOLAR CITY CORPORATION ASTRID BLANCO 24 ST MARTIN STREET BLD 2UNI 'WI-BOROUGH,MA 01752 Undersecretary Not valid without signature o f; ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONIC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD .BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT ,� �� �h PV1 COVER SHEET 1 � k �•- PV2 SITE PLAN STRUCTURAL VIEWS ' , .. PV4 THREE LINE DIAGRAM :°, Cutsheets Attached LICENSE GENERAL NOTES GEN #168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION ELEC 1136 MR OF THE MA STATE BUILDING CODE 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. ;' MODULE GROUNDING METHOD: ZEP SOLAR �- AHJ: North Andover REV BY DATE COMMENTS REV A NAME DATE COMMENTS UTILITY: National Grid USA (Massachusetts Electric) ' �M JB-0182682 0 o PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBERCHAMPY, CAROLYN CHAMPY RESIDENCE ,,,So�arCit CONTAINED SHALL NOT BE USED FOR THE KIIIIon Madden BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �•.,,z Y NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 152 WAVERLY RD 14.3 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St.Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (55) TRINA SOLAR # TSM-260PDO5.18 PAGE NAME: SHEET: REV DATE Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T: (650)636-1028 F: (650)636-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE1000OA—USOOOSNR2 (978) 420-5267 COVER SHEET PV 1 12�15�2015 (BBB)—SO.-CITY(765-2469) www.solarcitycom PITCH: 42 ARRAY PITCH:42 MP1 AZIMUTH: 197 ARRAY AZIMUTH: 197 MATERIAL: Comp Shingle STORY: 2 Stories PITCH: 42 ARRAY PITCH:42 MP2 AZIMUTH: 17 ARRAY AZIMUTH: 17 e e ; �� MATERIAL: Comp Shingle STORY: 2 Stories S 1 1 rD t B 1 t f f 1 rr ZdW y LEGEND Front Of House (E) UTILITY METER & WARNING LABEL 6 mpNU INVERTER W1& WARNING LABELSINTEGRATED DC DISCO o © DC DISCONNECT & WARNING LABELS AC AC DISCONNECT & WARNING LABELS OB DC JUNCTION/COMBINER BOX & LABELS O DISTRIBUTION PANEL & LABELS _ - AC Lc LOAD CENTER & WARNING LABELS �9 p DEDICATED PV SYSTEM METER JASON N IAEA AC TOMAN `4 1 M 1 Inv q 0 STANDOFF LOCATIONS STRUCTURAL. � `__�� � CONDUIT RUN ON EXTERIOR Na.x;15514 CONDUIT RUN ON INTERIOR ;z GATE/FENCE HEAT PRODUCING VENTS ARE RED iL � 5/2015 Q r ` hPINTERIOR/1Fence TE OR EQUIPMENT IS DASHED L-J Digitally signed by Jason Toman SITE PLAN Date:2015.12.15 21:15:44-07'00' Scale: 1/8" = 1' E 01' 8' 16' W VONS CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE J B=018 2 6 8 2 0 0 \\\ CHAMPY, CAROLYN CHAMPY RESIDENCE Killian Madden SolarCity.BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNRNG SYSTEM: NOR SHALL IT BE DISCLOSED IN ODLE OR IN Com Mount Type C 152 WAVERLY RD - 14.3 .KW PV ARRAY ►�� ORT TO OTHERS OUTSIDE THE RECIPIENTS p — 4 P ORGANIZATION EXCEPTINWTH MODULES— — -- NORTH ANDOVER, MA 01845 �- THE SALE AND USE OF THE RESPECTIVE (55) TRINA SOLAR # TSM-260PD05.18 24 St. Martin Drive.Building 2,Unit 11 SbLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV DATE: Marlborough, MA 01752 PERMISSION OF SOLARCITY INC. I T. (650)638-1028 F: (650)638-1029 SOLAREDGE SE10000A—USOOOSNR2 (978) 420-5267 SITE PLAN PV 2 12/15/2015 (Baa)-sa-CITY(765-2489) www.solarcity.com t ` (E) COLLAR TIE (E) KNEE WALL (E) COLLAR TIE S1 (E) KNEE WALL ( LBW (E) LBW S1 4" 8" (E) LBW (E) LBW (E) LBW (E) LBW SIDE VIEW OF MP1 NTS B SIDE VIEW OF MP2 NTS MPJ X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" STAGGERED MP2 I X-SPACING I X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES PORTRAIT 1 48" 20" LANDSCAPE 72" 1 4" 1STAGGERED RAFTER 1-7/8"x5"@ 24"OC ROOF AZI 197 PITCH 42 STORIES:2 PORTRAIT 48" 20" ARRAY AZI 197 PITCH 42 RAFTER 1-7/8"x5"@ 24"OC ARRAY AZI 17 PITCH 42 F AZI 17 PITCH 42 STORIES:2 C.J. 2"x6"@24"OC Comp Shingle C.J. 2"x6"@24"OC Comp Shingle PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. ZEP COMP MOUNT C ZEP FLASHING C (3) (3) INSERT FLASHING. (E) COMP. SHINGLE C(4)F PLACE MOUNT. (1) (E) ROOF.DECKING U (2) U INSTALL LAG BOLT WITH n (5) JASON WIL IAM 5/16 DIA STAINLESS (5) SEALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH 0 TDMAN WITH SEALING WASHER (6) BOLT & WASHERS0 STRUCTURAL . � (2-1/2" EMBED, MIN) No.51554 (E) RAFTER , , 51 STANDOFF �roNAL. 1 15/2015 CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION- DESIGN: JB-0182682 00 CONTAINED SHALL NOT E USED FOR THE CHAMPY, CAROLYN CRAMPY RESIDENCE Killian Madden �;;,SolarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC.. MOUNTING SYSTEM: �., r0 NOR SHALL IT BE DISCLOSED IN WHOLE OR INL(55) ount T e C 152 WAVERLY RD 14.3 KW PV ARRAY PART IZ OTHERS OUTSIDE THE RECIPIENTS NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH � 24 SL Martin Drive, Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE NA SOLAR # TSM-260PDO5.18 Marlin Dri h, MA ing ZSOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEEP• REV. DAIST: (650)638-1028 F: (650)638-1029 PERMISSION of SOLARCITY INC. GE SE10000A—USOOOSNR2 (978) 420-5267 STRUCTURAL VIEWS PV 3 12/15/2015 (86B)-SDL-CITY(765-2489) www.solarcity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO TWO (N) GROUND Panel Number:BR202OB100 Inv 1: DC Ungrounded GEN 168572 ODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:12 805 840 Tie-In: Supply Side Connection INV 1 -(1)SOLrter; 1 #SE10000V, 97.5OSNR2 LABEL: A -(55)TRINA SOLAR # TSM2360P PTC, # PP Y Inverter; 10 0W, 240V, 97.5%q w Unlfed Disco andZB,RGM,AFCI PV Module; OW, 236.9W PTC, 40MM, Black Frame, H4, ZEP, 1000V ELEC 1136 MR Overhead Service Entrance INV 2 Voc: 38,2 Vpmax: 30.6 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 125A MAIN SERVICE PANEL E 10OA/2P MAIN CIRCUIT BREAKER SolarCity (E) WIRING TRANSFER SWITCH CUTLER-HAMMER Inverter I Disconnect CUTLER-HAMMER 5 A Ti 7 Disconnect 6 SOLAREDGE A Dc+ rB 60A SE10000A-USOOOSNR2 Dc- MP 2: 1x16 C ECIC T.V ------------ -- --- - Z-- 3--- LA Lt r ------- -- - --------- B 12 I - - - � FROM N Dc 1 4 DC- MP 1: 1x19 GENERATOR GND _ ____ GND _____-_----_--___________ _EGC/ -__ DC+ Dc+ MP 1: 1x20 - G� T N DC- DC- I I -J GND EGC ------ --- ------------ --+----- ---EGC -- ---------- -- J i (1)Conduit Kit; 3/4" EMT N I I p I z z I c� I GEC TO 120/240V SINGLE PHASE i I UTILITY SERVICE TO MSP i I i I i I . i PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN VAS MAX VOC AT MIN TEMP GroygdRod (1)CUTLER-HAMMER #DG222NGB A (1)SolarCityy 4 STRING JUNCTION BOX r 88, perDisconnect; 60A, 24OVac, Fusible, NEMA 1 AC 2x2 STR GS, UNFUSED, GROUNDED DC (2)ILSCO @ IPC O-#6 -(1)CUTLER XMMER DG10ONB Insulation Piercing Connector; Main 4/0-4, Tap 6-14 Ground/Neutral K#it; 60-10DA, General Duty(DG) PV (55)SOLAREDGE 300-2NA4AZS - 1CUTLER-HAMMER #DS16FK PowerBox Optimizer, 30OW, H4, DC to DC, ZEP SUPPLY SIDE CONNECTION. DISCONNECTING MEANS SHALL BE SUITABLE Class R Fuse Kit SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. -(2)FERRAZ SHAWMUT #TR60R PV BACKFEED OCP nd (1)AWG#6, Solid Bare Copper Fuse; 60A, 25OV, Class RK5 -(1)Ground Rod; 5/8" x 8', Copper C (1)CUTLERHAMMER #DG222URB Disconnect; 60A, 240Vac, Non-Fusible, NEMA 3R ( )N ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION NO. 2, ADDITIONAL -(1)CUTLER; MMERK#tD60-01OOA General Duty(DG) ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE Grou� 1 AWG#6, THWN-2, Black 6��Tr' 1 AWG#6, THWN-2, Block (1)AWG 18, THWN-2, Black Voc* =500 VDC Isc -30 ADC (2)AWG #10, PV Wire, 60OV, Black Voc* =500 VDC Isc =15 ADC OL (1)AWG#6, THWN-2, Red O Isr((1)AWG#6, THWN-2, Red - O (1)AWG#J8, THWN- Red Vmp =350 VDC Imp=28.59 ADC O 1)AWG #6, Solid Bare Copper EGC Vmp =350 VDC Imp=11.73 ADC ..7(1)AWG #6, THWSoIid B, White NEUTRAL Vmp =240 VAC Imp=42 AAC IL�LL-(1)AWG#10,TM 22 Greene NEUTRAL EGC GEC.V(1p)ConduO,K tC 3/4 I EMT.42. . C.. (1)AWG#10, THWN-2,g Block been EGC C.Voc* .=500 VDC Isc =15 ADC (2)AWG#10, PV Vire, 600V, Black Voc* =500 VDC Is =15 ADC -(1)AWG#6,.Solid Bare.Copper. GEC. . . -(1)Conduit.Kit:.3/4".EMT. . . . . . . . . . . . . . . . . . (1)AWG#8. . . . . . . . . . . . .. . ./ O (1)AWG#10, THWN-2, Red Vmp =350 VDC Imp=11.73 ADC O (1)AWG#6, Solid Bare Copper EGC Vmp =350 VDC Imp=13.93 ADC . . . . . 0)AWP#10, THHN/THWN-2,.Creen. EGC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . (2)AWG#10, PV Wire, 600V, Block Voc* =500 VDC Isc =15 ADC O (1)AWG#6, Solid Bare Copper EGC Vmp =350 VDC Imp=14.66 ADC CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: - PREMISE OWNER: DESCRIPTION: DESIGN: \\` JB 0182682 00 , CONTAINED SHALL NOT USED FOR THE CRAMPY, CAROLYN CRAMPY RESIDENCE Killian Madden solarCity.BENEFIT OF ANYONE EXCEE PT SOLARCITY INC., MOUNTING SYSTEM: ,NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 152 WAVERLY RD 1.4.3KW-PV -ARRAY_ _ - - - - - r� PART TO OTHERS OUTSIDE THE RECIPIENTS Comp Mount Type C ORGANIZATION, EXCEPT IN CONNECTION WITH- MODULES--- - -- - - - NORTH ANDOVER, MA 01845 e THE SALE AND USE OF THE RESPECTIVE (55) TRINA SOLAR # TSM-260PDO5.18 24 St.Martin Drive,Building 2,Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: Marlborough,MA 01752 PERMISSION OF SOLARCITY INC. [INVERTER: 978420-5267 PV 4 12/15/2015 (888)-(650)cITY�(7028248sj650)38-10tycam SOLAREDGE SE10000A-USOOOSNR2 ) THREE LINE DIAGRAM i Label Location: Label Location: �� ,:� � Label Location: (C)(CB) (AC)(POI) (DC)(INV) Per Code: _ Per Coder Per Code: �. ,,�, „ NEC 690.31.G.3 I V06 ° NEC 690.17.E " ° ° NEC 690.35(F) i IN Label Location: ° ° 0 ® • TO BE USED WHEN (DC)(INV) o•s o -�O ® ° a • o INVERTER IS Per Code: UNGROUNDED� ® ` _ � � � � NEC 690.14.C.2 Label L �r a Location: Label Location: ° olv� "�i °�ojo �� (POI) ru "orr (DC)(INV) ' .F Per Code: ° luu Per Code: AN NEC 690.17.4; NEC 690.54 NEC 690.53 D Co O Label Location: ® ll� (DC)(INV) - ` i Per Code: ,z NEC 690.5(C) 1� Label Location: ®�,o�i�Io ®' •` 1� l� `®" POI Per Code: NEC 690.64.B.4 Label Location: 1 ® �° (DC)(CB) Per Code: Label Location: NEC 690.17(4) �iiil� r`Iti (D) (POI) Per Code: 0 o � . - 690.64.B.4 4 ... ° o • '` �.-,_; -fir.., �, gym; ;,,: _r. Label Location: ® (POI) Per Code: Label Location: - ° NEC 690.64.B:7 (AC) (POI) 0® ® - ® (AC): AC Disconnect Per Code: ®® (C): Conduit NEC 690.14.C.2 (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect Label Location: (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect �(s (AC)(POI) ° Per Code: (LC): Load Center (M): Utility Meter e - o NEC 690.54 (POI): Point of Interconnection CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR ; r�ry 3055 Clearview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED San Mateo,CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, Label Set T:(650)638-1028 F:(650)638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE ��, Solatti. (888)-SOL-crry(765-2489)www.solarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. o 13 ^SolarCity ZepSolar Next-Level PV Mounting Technology ',SolarCity ZepSolar Next-Level PV Mounting Technology Zep System Components ..L for composition shingle roofs - # r Up-roof Leveling Foot erm,nd Zep Interlocksa +I - Part No.850-1172 �` "` •` ETL listed to UL 467 UP compatible PV Modula « Zep amore RoM Attachment Array Vdit ,. _,w.. Comp Mount Part No.850-1382 Listed to UL 2582 Mounting Block Listed to UL 2703 Q��MpAT� Description PV mounting solution for composition shingle roofs E F, 0 Works with all Zep Compatible Modules OM% Auto bonding UL-listed hardware creates structural and electrical bond • Zep System has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2" . Interlock Ground Zep V2 DC Wire Clip UL LISTED Specifications Part No.850-1388 Part No.850-1511 Part No.850-1448 Listed to UL 2703 Listed to UL 467 and UL 2703 Listed to UL 1565 • Designed for pitched roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain Array Skirt,Grip,End Caps Part Nos.850-0113,850-1421, 850 zepsolar.com zepsolar.com Listedd tto UL 1 1565565o 67 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for _ each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM t Y T , w Y 4 � SolarEdge Power Optimizer solar,=oo so l a ro ® Module Add On for North America s y P300 / P350 / P400 SolarEdge Power Optimizer PUP :11F" Module Add-On For North America P3DD P35D P400 for 60-cell PV for 72-cell PV ( ( (for 96-ce11 PV modules) modules) modules) P300 / P350 / P400 INPUT ,„. x Rated Input DC Power"' 300 350 400 W, - ® Absolute Maximum Input Voltage(Voc at lowest temperature) 48 60 80 Vdc MEET Operating Range ...... .. ..... ..... ...... ....8. 48 .............g..60 ... ... 8 80....... ..Vdc.... Rg'a "%' - Maximum Short GrcuR Current(Isc)....... ...... .. ..........................................10. ... Adc..." ?,,x r a Maximum DC Input Current 12.5 Adc ............. .......... ....... ... .... ........... ... .... ..... ........ ... .. ......... ............... - Maximum Efficiency 99.5 % Wei hted Efficiency... 98 8 % _. x�. ... ...... .............. . .... ........... ...... ..... ... ..._ .,� ` ,� Overvoltage Category II _ OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) _ -- '" o ® Ma m m0 tp tC went - - 15. Output Voltage ...... ....... 1 ..... .. 60 ... ... OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) - Safety Output Voltage per Pow r_Opem STANDARD COMPLIANCE 1 EMC FCC Part15 Class B IEC61000 6 2 IEC61000-6-3 .... ......... izer c .. IEC62109 1(lass I safety),UL1741 RoHS ........ .. ................ ...... ...... .. ..... .... .....Yes ....... .........-.. .. ...... INSTALLATION SPECIFICATIONS _ __ _ _ _ _ __ Maximum Allowed System Voltage 1000 Vdc .. ... ..... .... .... Dimensions(W x L x H) 141 x 212 x 40.5/555 x 8.34 x 1.59, mm/m, Weight(including cables) .. ........... .. ........950/2.1. .... ... ......... - ✓ .... ............................ .... .... .. .. .I..................... ..... ......... .................. ph ..MC4/Amenol(Tyco... ....... ... ....... I Output Wire Length ... .. ..0.95./.3.0 .. .........Amphenl 2/i9 ....... ..... .. ./ft... .. .nnecto.. ... . .. .... ..... ... ble Insulated..... ... .......... ..... .. ... . -.- Operating Temperature Range �u40 +85/40-+185 '`1. Protection Rann I!6 /NEMA4.... ......... ..... .....- ;, �� .......... g.......................... ............ .. ... .. .... .... ... .. ... .......... _- < a "` Relative Humidity 0 100 % .. r n oa i ... ... ... .. ... .... .......... ......................... ...... ..... m o PV SYSTEM DESIGN USING A SOLAREDGE THREE PHASE THREE PHASE SINGLE PHASE INVERTER 208V 480V PV power optimization at the module-level Minimum String Length(Power Optimizers) s l0 18 Up to 25%more energy Maximum Strang Length(Power Optimrzer.. 25 25 50 1.1 —Superior efficiency(99.5% Maximum Power per String 5250 6000 12750 W I� - .. .. -. � .. ............ ? ... g ... .. ...... ........ .... ....... ..... ............. ......... ..... .......... .... .......... .................. i ) I Parallel Strings of Different Lengths or Orientations Yes - Mitigates all types of module.mismatch losses,from manufacturing tolerance to partial shading ( - - Flexible system design for maximum space utilization " — Fastinstallation with a single bolt _ — Next generation maintenance with module-level monitoring w Module-level voltage shutdown for installer and firefighter safety � �� USA - GERMANY - ITALY J FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us x � ; aJ y THE 79mmount MODULE TSM-PD05.38 Mono Multi Solutions DIMENSIONS OF PV MODULE ELECTRICAL DATA,a STC unit:mm Peak Power waits-P,vx(Wp) 245 250 255 260 941 �. Power Output Tolerance-PA (%) 0-+3 THE p C O e Maximum Power Voltage-Vmp(V) 29.9 30.3 30.5 30.6 Maximum Power Current-If-Imre(A) 8.20- 8.27 8.37 8.50 NAME-F ' Open Circuit Voltage-Voc(V) 37.8 : 38.0 38.1 38.2 0 we s.'a Short Circuit Current-Isc(A) 8.75 8.79 8.88 9.00 $rPLLi1C HOLE . Module Efficiency nm(%) .15.0 15.3 15.6 15.9 ® iF� STC:Irradiance 1000 W/m',Cell Temperature 250C.Air Mass AMI.5 according to EN 60904-3. Typical efficiency reduction of 4.5%at 200 w/m'according to EN 60904-1. 0 0 ELECTRICAL DATA @ NOCT 3 /f ��� Maximum Power-P(W p) 182 186 190 193 I If�J Maximum Power Voltage-Vmr(V) 27.6 28.0 28.1 28:3 J MULTICRYSTALLINE MODULE ' 604.3 GROONDING NOLE Maximum Power Current-l-(A) 6.59 6.65 6.74 6.84 A A Open Circuit Voltage v Voc V 35.1 35.2 35.3 35.4 WITH TRINAMOUNT FRAME g ( )ls ( ) I Short Circuit Current(A)-Isc(A) 7.07 ' 7.10 7:17 7.27 E NOCT:Irradiance at 800 W/m'.Ambient Temperature 200C.Wind Speed 1 m/s. Btz tao FS/r +1Yr�Y1 2 tV► W � Back View POWER OUTPUT RANGE MECHANICAL DATA f' 1 Solar cells Multicrystalline 156 x 156 mm(6 inches) - Fast and simple to install through drop in mounting solution Cell orientation 60 cells(6 x 10) r keffI {'T\} f Module dimensions 1650 x 992 x 40 mm.(64.95 x 39.05 x 1.57 inches) s O -'g Weight 21.3 kg(47.0 lbs) v MAXIMUM EFFICIENCY d Glass 3.2 mm(0.13 inches),High Transmission,AR Coated Tempered Glass A-A Bocksheet White - 9 Good aesthetics for residential applications Frame Black Anodized Aluminium Alloy with Trinamount Groove i �+D� - r � JP 65 or IP 67 rated 3 + ! `, I-V CURVES flF PV MODULE(245W1 Cables _ 0--+3% b Q "'""�"�� Cables Photovolidic Technology cable 4:0 mm'(0.006 inches'): ..._.._ .... .............................. _.. ...... ....__.-_ __...... .. 100° 1200 mm(47.2 inches) POWER OUTPUT GUARANTEE 9ro "" Fire rating Type ' Highly relable due to stringent quality control -8° Scow/m= ` «Gro m .. _..._ ,....��... .....,, ............_. .._... _.._. 0 1 Over 30 in-house lesls(UV, TC HF,and man;more; i � As n I�:ading rvloocil manifac tures '-" In-house testing<goeS well(cyn-nd certiflcalicr-i reauirements Ij 4.ro 400wim, TEMPERATURE RATINGS MAXIMUM RATINGS G'ne)d n-)dgeneration on photo) Itnic 2a.roro 200w/m' -.,. TNominal Operating Cell Operational Temperature -40- 85°C prot ts, vF believe.Close 44-C(t2`C) ^o0 r T;on with oUr YClrtnerS emperature(NOCT) m -- Maximum',System IOOOV DC(IEC) I v 0'. Temperature Coefficient of P- -0.41%/°C Voltage IOOOV DC(UL) z cntl..c,.to st:c.. 35. local 0.ro IO.ro 21- 30.m 40.ro prese,jcH around t`ie:glob^..Trin is Temperature Coefficient of Voc -0.32%/'C Max Series Fuse Rating 15A Voltage(V) _ - able to provide C c-ep Y al service TemperaturCoefflcient of Isc 0.057/°C Certified to withstand challenging O h cus Y1er:n e h mark:a environmental e arts Lip f r nt oir innoval.1ve, condi ions rekcm,le, -or„tct atth the Docking 1 a = 24r-(`('--wint9 oad WARRANTY Of r:na as a siror:v,bankable M.y , partner. IN,are cornrriiifed �4�0 Pa 5rio'•.ro'oat P� 10 year Product Workmanship Warranty i TO OuTIdIng strategic,rnulua11y I benefc'alcoilobolatOn,Anth 25 year Linear Power Warranty _ - Insialler5,Glevelon's„dis"Ibutors (Please refer to product warranty,for details( and of Or partners os the - backbone of our shared sF ices iii CERTIFICATION C.:.iJ 1g SmortF.eroyTogether. LINEAR PERFORMANCE WARRANTY PACKAGING CONFIGURATION ----- 10 Year Product Warranty=25 Year Linear Power Warranty '` ` 1 o M e Co us Modules per box:26 pieces w' Trina Solar Limited ....... _ _ __._ _.___.-._- A Modules per40'contoiner:728 pieces vr �; ; V00%. y - Addifia °o' oaf yafUe Era C-11ANT Lana „90% S®tar`s fi wary o apt CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. �oMP4TB 70 Y 002014 Tr no Solar Limited.All ri hts reserved.Specifications included in this dotasheet ore subject io .Q t amsolar O 80% T[�on-asola" change without notice. 9 tt.SmnrC Er? `f' e'Y� TageAhetYears 5 10 15 20 25 Smart':.^Cray large..her `n -S ndata _. lyd,3 try..tand3-i THE Vinelmount MODULE TSM-PDO5.18 Mono Multi Solutions j DIMENSIONS OF PV MODULE ELECTRICAL DATA STC unit:mm Peak Power Wafts-PMAX(Wp) 250 _ 255 260 265 _.... 941 Power Output Tolerance-PmAx(%) 0-+3 rt rt UNazE. Maximum Power Voltage-V-I 30.3 30.5 30.6 30.8 ux~ o Maximum Power CurrenlImpMrP((A), 8,27 8.37 8.50 .8.61 W ATE o Open Circuit Voltage-Voc(V) 38.0 38.1 38.2 38.3 H'0912 Short Circuit Curreni-Isc(A) 8.79 8.88 9.00 9.10 MODULE #��5(���I, 1 STAWNG NOEE - , 1_,..� ISI 8 Module Efficiency nm(%) 15.3 15.r 16.9 16.2 STC:Irradiance 1000 W/m2,Cell Temperature 25°C,Air Mass AM1.5 according to EN 609043. Typical efficiency reduction of 4.5%at 200 W/m'according to EN 60904-I. 0 0 - ELECTRICAL DATA C7 NCCT i - i Maximum Power-P-(Wp) 186 190 .193 197 60 CELLMaximum Power VoltageMaximum IV) 28.0 28.1 28.3 28.4 - MULTICRYSTALLINE MODULE 600.3 GROUNDING I-E Maximum Power Current-IMVE(A) 6.65 6.74 6.84 6.93 WITH TRtNAMCJUNTFRAME PD05.18 ,:-ORA.N 1 A A Open Circuit voltage(V)-Voc(V) 35.2 35.3 35.4 35.5 Short Circuit Current(A)-Isc(A) 7.10 7.177.27 7.35 -I NOCT:Irradiance at 800 W/m2,Ambient Temperature 20°C.Wind Speed 1 m/s. I r ' 6 Back View aT2. Tao MECHANICAL DATA POWER OUTPUT RANGE Solarcells Mulficrystalline 156.156 mm(6 inches) Fast and simple to install through drop in mounting solution Cell orientation 60 cells(6 x 10) ���777 - ,. Module dimensions 1650 x 992 x 40 mm(64.95•39.05><1.57 inches) II * _ € .Weight u 19.6 kg(43.12 lbs) ® Glass 3.2 mm(0.13 inches),High Transmission,AR Coated Tempered Glass MAXIMUM EFFICIENCYj Backsheet White A-A Frame Black Anodized Aluminium Alloy ' Good aesthetics for residential applications I J-Boz IP 65 or IP 67 rated i - - - Cables Photovoltaic Technology cable 4.0 mm2(0.006 inches'), 1200 mm(47.2 inches) ................. .. ._. ..._.. ......... .................... ........._. ..----- .......... ._....... I-V CURVES OF PV MODULE(2600) _. t ' POSITIVE POWER TOLERANCE j +oou Connector H4Amphenol o 3000w ml Fire Type UL 1703 Type 2,for Solar City highly reliable due to stringent quality control • Cver 30 in-house T•sis;JV, IC„HF,and frany mone) As o leading global ma tufa.-urer • In-hour les-ling gees well beyond cerilfi;;atlon resat j inenis 2 s.00 saowm' � TEMPERATURE RATINGS MAXIMUM RATINGS a o.next genera on. 1lotovoltcic m y. • PID res•sir�t E 500 prod, ts,we I .leve close a.00 Temperature(NOCT)Nominal Operating Cell 44°C(+2°C) Operational Temperature!-40-+g5°C cooperation with our pr�Ntner; 30o m Maximum System 1000V DC(IEC) is critical`O.. success. With lc'.:G•^! z.00 Temperature Coefficient of PM --0.41%/°C Voltage. 1000v DC(UL)' !, presence rrriund tht;globe,Trpr="T is �.00 `i Temperature Coefficient of Voc -0.32%/°C Max Series Fuse Rating 15A once to provide exceptional service o.00 to ea n cu oro r in each arkeT Certified to withstand challenging environmental a o zo 3. Ao w ;Temperature Coefficient of Ise 0.05%/°C sand Supplement r'ent our r,lorative, conditions re.i;able producls,with 411e h ckrTg 2400 Pa wine load of Trina is G Strong,bankable -- WARRANTY partner. We e: 3r ton: ed 5400 Fla snow loa, to building strut q a c,m 'ally CERTIFICATION 10 year Product Workmanship Warranty en Acial c olloborafionwith 25year Linear Power Warranty insfcall €S :lelop . ,distributors ca- (Please refer to productworranty fordetails) <I and oth r ,ar ,ers as theustED ° bockbone of a r shvxed Success in drivinaSrrarlEnergy Tog her. LINEAR PERFORMANCE WARRANTY 10 I PACKAGING CONFIGURATION o EMsE coMI-NT Modules p' 10 Year Product Warranty=25 Year Linear Power Warranty per box:26 feces w Trina Solar limited - I P Modules per 40'container:728 pieces f w�yw1nnasalOr novo tl00% -_ _I Additi a abet value Ir m 9o%-artt trine Soloo's linear yy o - arfati{tr CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. GOMPglB TvQ l7 80% O g p 02015 Trina Solar Limited.All rights reserved.Specifications included in this datasheet are subject to anmsol �C �� ���®Ian change without notice. Smart Energy Together Smart Energy Together A e Years 5 10 15 20 25 CDAtppt� 13 Yrina Siand3r,J [ irimtry."-1--'Jand - `U'N Singlele Phase Inverters for North America©SO�aSE3000A-US/SE3800A-US/SE5000A-US/SE6000A-USsolar a SE760OA-US/SE10000A-US/SE1140OA-US f SE3000A-US SE3800A-US SESOOOA-US 5E6000A-US 5E7600A-US SE10000A-US 5E11400A-US - OUTPUT SolarEdge Single Phase Inverters � � 1.... . ... . �9980@2og� . . . © rf Nominal AC Power Output 3000 3800 5000 6000 7600 11400 VA ............ ........... .... ........... ... ... 10000 240y ...... ..5400 @ 208V 10800 @ 208V. . ........ .. lam"� - � .� Max.AC Power Output 3300 4150 6000 8350 12000 VA For North America 5450.�24oy... ..... ....... .......... �o95o.�z4o� . . ............ ��"� ..v' AC Output Voltage Min.Nom.Max.1�) ,. 183-208- ..............229 Vac SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ E , AC Output Voltage Mm.Nom:Max.111 SE7600A-US/SE1000OA-US/SE11400A-US 211 240 264 Vac ........ ... .. .... .. .... ........................... ' < ,, Frequency Min.-Nom.-Max.(" 59.3 60-60.5(with HI country setting 57-60 60.5) Hz ...�.................................... .......... .... ...... ...24 @ 208V'.. ...... ... ............ ..48 @ 208V... .............. ......... Max P Continuous Output Current 12 5 16 25 32 47 5 A n, 21 240V 42 240V GFDIhreshold.. ......... ..... .... ... ... ...... .......... .................... .1.............................. ..... . . A Utility Monitoring Islanding Protection,Country Configurable Thresholds Yes Yes L INPUT - - ---- - } Maximum DC..... STC) 4050 5100 6750 8100 .10250 13500 15350 W ..Transformer less,Ungrounded. ..Yes Max In ut Volta a 500 Vdc P g 325 @ 208V/350 @ 240V Vdc �r-� f ,.,,. _, z. .............. ....... . . ... ......... ... .. .. .16.5 ....... ... ............ 208V... .......,.. ... ......... a E ? ;i a.,< : .Input entlzi 0 OV 34.5 Adc x is Max Curr 9 5 13 18 23 a 15.5 24 V 30.5 24 I Max.Input Short Circuit Current ....................................... 45.............................. . ......................... .... .... � T Reverse Polarity Protection Yes Yes ........ ........ .............. ... ..... ............................. ....... _..... ....................................... ..................... .......... - f r ti Ground Fault Isolation Detection 600kst Sensitivity _ Maximum Inverter Efficiency 97.7 98.2 98.3 95.3 98 98 98 % r ............ ... . ... .... .... ............ ........... ...97.5 @ 208V. . . ..... ... ... ..... .. ..97 @ 208V. .............. ......... CEC Weighted Efficiency 97.5 98 OV 97.5 97.5 97.5 24 Nighttime Power Consumption.. .. ...... ..... . ... .......... ..9$.°�..�... ... ....... ...... ,... ......... ...... ...9Y'<q...... ..... ...W.... o 3� 97 24 ADDITIONAL FEATURES -- - .„ Supported Communication Interfaces R54S5,RS232,Ethernet,ZigBee(optional) ...................... Revenue Grade Data,ANSI 012.1 .... ..... ..... ... .....Optionall'1 ... ... ..... .. ..... ........................ ... ..... .. ... .. .... ........ ..... .. .. ....... .... .. .... ... ........... ...... ................. ...................... ..... .... ... . ... .... ......... Rapid Shutdown-NEC 2014690.12 Functionality enabled when SolarEdge rapid shutdown kit Is installedl01 ti STANDARD COMPLIANCE Safety... ... .... .. .. .... .... ................ ... . ................ ...... 998,UL19 ..... ... .................................... ... ..... ... ..Grid Connection.Standards......... ... .......... ....... .... .............. 16IEEE1547 98 ................ ......... .................... ..... ... .. ...... ........ .. UL1741,UL ,CSA 22.2 INSTALLATION SPECIFICATIONS - -_.,..._ -..._ _. �� _..____-__ _ i�sions _ _ _ _ FCC art15 class B t output conduit size/AWG range 3/4"minimum/16 6 AWG 3/4 minimum/8 3 AWG < . .. . . . ..... ... ....... ........ .. ... ..... ...... ... ... .... ........... .... ... .. ....... . .. ... ;.. � _- ��'�-� � �` s���: �� DC input condwt size/#of strings/ 3/4"minimum/1 2 strings/ AWG ran a 3/4"minimum/1-2 strings/16 6 AWG 14.6 AWG i �- n€ _*� "�" - a _ Dimensions with Safety Switch 30.5 x 12.5 x 10.5/ in/ f �� 5 ,� 30.5 x 12.5 x72/775 x 315 x 184 € -s�=a� .:. .� - < '� a ..�HxWxD)........... ....... .......... ............. .... ,..... ............... ..... .. .. ............... ....775 x 315 x.260. ...... .^?!!i. .. Weight with Safety Switch 51.2/23.2 54.7/24-7 88.4/40.1 Ib/kg ... ..... ... ..... ....... ............. ....................... .. .............. . ... . ... ..................................... .. .. ... ^$' = Natural convection - - Cooling Natural Convection andinternal Fans(user replaceable) - fan(user The best choice for SolarEdge enabled systems .................. . .......... .replaceabe).. Noise <25 <.50 dBA +■ - Min:Max.Operating Temperature Superior-efficiency(98%) p ,.Range....,..., -13 to+140/-25to+60(-40 t..+6.version available...) 'F/.. Integrated arc protection Type 1 or NEC 2011630.11 compliance I Protection Rating ........ .NEMA 3R ...................... ..... ................................ Small,lightweight and easy to install on provided bracket For other tegonal settings please contact SolarEdge support Built-in - of A higher current source may be used,the inverter 'll limit its input current to the values stated. 'module-level monitoring ni Revenue grade'nwrter P/N:SEz an U5p00NNR2(for 760OW mveft r5E7600A-USCO2NNR2). 1°i Rapid shutdown kit P/N SE1000 R5D 51 -. Internet connection through Ethernet or wireless Isl AO version P/N:SE-A-US000NNU4(for 760OW inverter:SE7600A-US002NNU4). _ - Outdoor and indoor installation - Fixed voltage inverter,DC/AC conversion only g - _ _ = - Pre-assembled Safety Switch for faster installation - Optional-revenue grade data,ANSI C12.1 sunspec 0 t USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THEN ETH ERLANDS-ISRAEL www.SOlared e.US g