Loading...
HomeMy WebLinkAboutBuilding Permit #735-16 - 163 OLYMPIC LANE 12/15/2015 NORTH r � O`�t,ao BUILDING PERMIT ,.� b �. °w:a o� TOWN OF NORTH ANDOVER V�°yIPPI ATI N FOR PLAN EXAMINATION / A L C 0 0 Permit NOI Date Received4� Date Issued: �i- �/ 1 � �SSACHUS�tI(`' IMPORTANT: Applicant must complete all items on this page LOCATION Print PROPERTY OWNER `THO M A-S 1�EC-D N D 0 Print MAP NOA PARCEL: ZONING DISTRICT: Historic District yes no Machine Shop Village yes no TYPE OF IMPROVEMENT PROPOSED USE Residential Non- Residential j ❑ New Building ❑ One family ❑Addition ❑ Two or more family ❑ Industrial b Alteration No. of units: ❑ Commercial ❑ Repair, replacement ❑ Assessory Bldg ❑ Others: ❑ Demolition ❑ Other CiSeptic ❑Well ❑ Floodplain ❑Wetlands ❑ Watershed District 11 Water/Sewer INSTALL. 3q SO)--AA- PANELS bN TXtSTIN& IZImF SYsTS H SIZE D F q.6 q k V`J Identification Please Type or Print Clearly) OWNER: Name: THOMAS SeCoN D U Phone: 611, CW4. -M63 Address: ( �3 OLYMPIC U'� CONTRACTOR Name: DAN MCCTR-kT�H Phone: 9i_ 'I" 1`116 Address: 450- P V&Ac,4 -NT ST -JF L.- MA1-DE-N H-& 0j.ttq g Supervisor's Construction,License: Exp. Date: OT IS j,=& Home Improvement License: t6��j t Exp. Date: t)S J ID-7/j_DI--1 ARCHITECT/ENGINEER Phone: Address: Reg. No. Cb FEE SCHEDULE.BULDING PERMIT.$12.00 PER$1000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PER S.F. Total Project Cost: $ FEE: $ Check No.: Receipt No.: NOTE: Persons tr­a`ckink with unregistered contractors do not have ccess to a guar my fund Signature of Agent/Owner Signature of contractor d BUILDING PERMIT' O� NO C. q TOWN OF NORTH ANDOVER - APPLICATION FOR PLAN EXAMINATION ° ; ' Permit No#• Date Received SSACHV`-'� Date Issued: IMPORTANT: Applicant must complete all items on this page LOCATION Print PROPERTY OWNER Print 100 Year Structure yes no MAP PARCEL: ZONING DISTRICT: Historic District yes no Machine Shop Village yes no I TYPE OF IMPROVEMENT PROPOSED USE Residential Non- Residential ❑ New Building ❑ One family El Addition ❑Two or more family El Industrial ❑Alteration No. of units: ❑ Commercial ❑ Repair, replacement ❑Assessory Bldg ❑ Others: ❑ Demolition ❑ Other -------- 011-1 .___0114 fi . ❑1FI©odplan D�Wetlrandsa 0' WatershetlslDistnct -- DESCRIPTION OF WORK TO BE PERFORMED: Identification- Please Type or Print Clearly OWNER: Name: Phone: Address: Contractor Name: Phone: Email: Address: Supervisor's Construction License: Exp. Date: Home Improvement License: Exp. Date: ARCHITECT/ENGINEER Phone: Address: Reg. No. •� 9 FEE SCHEDULE:BULDING PERMIT:$12.00 PER$1000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PER S.F. Total Project Cost: $ FEE: $ Check No.: Receipt No.: h40TE: Persons contracting with unregistered contractors do not have access to the guaranty fund r �... a 6 s.– c L t !. - .. t1 —.-..- ... —_- 5 i Plans Submitted ❑ Plans Waived ❑ Certified Plot Plan ❑ Stamped Plans ❑ TYPE OF SEWERAGE DISPOSAL Public Sewer ❑ Tanning(Massage/Body Art ❑ Swimming Pools ❑ Well ❑ Tobacco Sales ❑ Food Packaging/Sales ❑ Private(septic tank, etc. ❑ Pennanent Dumpster on Site ❑ THE FOLLOWING SECTIONS FOR OFFICE USE ONLY INTERDEPARTMENTAL SIGN OFF m U FORA PLANNING & DEVELOPMENT Reviewed On Signature_ COMMENTS CONSERVATION Reviewed on Signature COMMENTS HEALTH Reviewed on Signature COMMENTS Zoning Board of Appeals: Variance, Petition No: Zoning Decision/receipt submitted yes Planning Board Decision: Comments Conservation Decision: Comments F t- VWater& Sewer Connection/Signature& Date Driveway Permit DPW'Town Engineer: Signature: Located 384 Osgood Street FIDEPRA RdIV1EN �TempDumpster S F t ke 1, eqMM6.a at 124 Main Street- jr "e(�� ,wf�' � i` r .`<.� •f'-"ps'.`.; "�� iSR .w ...a.< ' Y�'. S�SI`' Jt � ! :!Y , 7Depart entsi nafiure/date te, #t r.,''�(',x,. y�•l' �+N � .( ' �P�'r°'�`{'. F .w +t `t' +w4 FT. i. � .f' a�..".�'�h. i�.i.as.�Y J:. n i' n.r )+v�' ys ? x t r = _ �. cTi '�3�{ + d� ,•krta }, y.e$r s� �y{R Y 4�i � � .�+ ,.,... _.:. .-� ., , L ., � ,t;+,�`"t�S't�s.s '!�k•.a v�' YtSi " 'Ej,...sem}�,".S -w Dimension Number of Stories: Total square feet of floor area, based on Exterior dimensions. Total land area, sq. ft.: I ELECTRICAL: Movement of Meter location, mast or service drop requires approval of Electrical Inspector Yes No ®ANGER ZONE LITERATURE: Yes No MGL Chapter 166 Section 21A—F and G min.$100-$1000 fine I NOTES and DATA— (For department use) II ® Notified for pickup Call Email Date Time Contact Name Doc.Building Permit Revised 2014 1 _ Building Department The following is a list of the required forms to be filled out for the appropriate permit to be obtained. ' Roofing, Siding, Interior Rehabilitation Permits Building Permit Application Workers Comp Affidavit Photo Copy Of H.I.C. And/Or C.S.L. Licenses Copy of Contract Floor Plan Or Proposed Interior Work Engineering Affidavits for Engineered products OTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit Addition Or Decks Building Permit Application Certified Surveyed Plot Plan Workers Comp Affidavit Photo Copy of H.I.C. And C.S.L. Licenses Copy Of Contract Floor/Cross Section/Elevation Plan Of Proposed Work With Sprinkler Plan And Hydraulic Calculations (If Applicable) Mass check Energy Compliance Report (If Applicable) Engineering Affidavits for Engineered products . OTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit New Construction (Single and Two Family) 4- Building Permit Application 4. Certified Proposed Plot Plan Photo of H.I.C. And C.S.L. Licenses Workers Comp Affidavit Two Sets of Building Plans (One To Be Returned) to Include Sprinkler Plan And Hydraulic Calculations (If Applicable) Copy of Contract 2012 IECC Energy code Engineering Affidavits for Engineered products i OTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg. Permit j In all cases if a variance or special permit was required the Town Clerks office must stamp the decision from the Board of Appeals that the appeal period is over. The applicant must then get this recorded at the Registry of Deeds. One copy and proof of recording must be submitted with the building application I Doc:Building Permit Revised 2014 i I Location '1 No. Date } • - TOWN OF NORTH ANDOVER Q . xLED z . .. �. . Certificate of,occupancy $ b Building/Frame Permit Fee $� 3 Foundation Permit Fee Other Permit Fee $ TOTAL $ Check# 29828 Building Inspector NORTH Town of : _ Andover Q .. y'' ' 00% z h ver, Mass , 140 COC NIC Nl WICK V x,95 R�reo U BOARD OF HEALTH Food/Kitchen PERMIT T LD Septic System THIS CERTIFIES THAT ........ ' a � ..................... ................ BUILDING INSPECTOR .... /...:'v F ..�7.......0.I. Foundation has permission to erect .......................... buildings oni..(0.7 yJL�,..... a Rough to be occupied as ........1.t.. 01.....k1.......... .tG�. ............................................... Chimney provided that the person accepting this permit shall in every respect conform to the terms of the application Final on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection, Alteration and Construction of Buildings in theJown of North Andover. PLUMBING INSPECTOR VIOLATION of the Zoning or Building Regulations Voids this Permit. Rough Final PERMIT EXPIRES IN 6 MONTHS ELECTRICAL INSPECTOR UNLESS CONSTRUCTIrot TRough Service ............... ...................................... Final BUILDING INSPECTOR GAS INSPECTOR Occupancy Permit Required to Occupy Buildinz Rough Display in a Conspicuous Place on the Premises — Do Not Remove Final No Lathingyor Dry Wall To Be Done , FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. Burner Street No. Smoke Det. DocuSign Envelope ID:9C4EF40B-D3F1-4BCA-9479-38AOB46F6A4B sunGEViTY" Homeowner's Agent Authorization Form State of Massachusetts ly Thomas Secondo (prim name) am the o owner f` r the property ert located. at address: p Y 163 Olympic Lane North Andover MA 01845 (print address) I hereby authorize Sungevity or its subcontractor to act as my Agent for the limited purpose of applying for and obtaining local building and other permits from the Authority Having Jurisdiction as required for the installation of a PhotoVoltaic System located on my Property. 00MUS, ned by Customer Signature: � zo6COmEoa41s... Date: 11/16/2015 Print Name: Thomas Secondo Sungevity MA dome Improvement Contractors License # 168430 66 Franklin Street, Suite 310 p 510.496.5500 866.SUN.4ALL Oakland.CA 94607 USA f 510.496.5501 www.sungovity.com DocuSign Envelope R 9C4EF40B-D3F1-4BCA-9479-38AOB46F6A4B sunGEVITY* Homeowner's Agent Authorization Form State of Massachusetts 1, Thomas Secondo (print name) am the owner of the property located at address: 163 Olympic Lane North Andover MA 01845 (print address) I hereby authorize Sungevity or its subcontractor to act as my Agent for the limited purpose of applying for and obtaining local building and other permits from the Authority Having Jurisdiction as required for the installation of a Photovoltaic System located on my Property. 0 S ned by 1 Customer Signature: 266comCDA419... Date: 11/16/2015 Print Name: Thomas Secondo Sungevity MA Home Improvement Contractors License # 168430 66 Franklin Street,Suite 310 p 510.496.5500 866.SUN.4ALL Oakland,CA 94607 USA [ 510.496.5501 www.sungevity.com The Commonwealth of Massachusetts Department of Industrial Accidents a d 1 Congress Street,Suite 100 Boston,MA 02114-2017 www.mass.gov/dia Workers'Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print Legibly Name (Business/Organization/Individual):United Solar Associates, LLC Address:452 Pleasant Street, Second Floor City/State/Zip:Malden, MA 02148 Phone#:855-786-1776 Are you an employer?Check the appropriate box: Type of project(required): 1.❑✓ I am a employer with 5 employees(full and/or part-time). 7. New construction 2.❑I am a sole proprietor or partnership and have no employees working for me in $, �Remodeling any capacity.[No workers'comp.insurance required.] 3.a I am a homeowner doing all work myself.[No workers'comp.insurance required.]t 9. El Demolition 10 ❑Building addition 4.❑I am a homeowner and will be hiring contractors to conduct all work on my property. I will ensure that all contractors either have workers'compensation insurance or are sole 11.❑Electrical repairs or additions proprietors with no employees. 12.EJ Plumbing repairs or additions 5.711 am a general contractor and I have hired the sub-contractors listed on the attached sheet. 13.❑ p Roof repairs These sub-contractors have employees and have workers'comp.insurance.t 14.MOther Solar Install 6.❑We are a corporation and its officers have exercised their right of exemption per MGL c. 152,§1(4),and we have no employees.[No workers'comp.insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name:TRAVELERS Policy#or Self-ins.Lic.#:7PJUB-5B50763-8-15 Expiration Date:7/23/2016 Job Site Address: 163 Olympic Ln City/State/Zip:N.Andover, MA 01845 Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. Ido hereby certify and theains and pe t' s �ry that the information provided above is true and correct. Si nature: Date: /Q i-0 IS Phone#:855-786-1776 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: AC40 CERTIFICATE OF LIABILITY INSURANCE °"TE'MM'°°'YYYY' 12/8/2015 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER NAME: Ax Asset One Insurance A/CNNo Ext): 714-625-8204 (A/C,No): 714-625-8290 575 Anton Blvd.,3rd FL ADDRESS: ara@solarinsure.com INSURER(S)AFFORDING COVERAGE NAIC# Costa Mesa CA 92626 INSURER A: Westchester Surplus Lines Insurance Company 10172 INSURED INSURER B: TRAVELERS PROPERTY CASUALTY COMPANY OF AMERIC 25674 United Solar Associates,LLC INSURERC: American Zurich Insurance Company 16535 452 Pleasant Street,Second Floor INSURER D: INSURER E: Malden MA 02148 INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSIR LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER AUULbUbK FOLICY EFF YYYY POLIO EXP LIMITS XCOMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE a OCCUR PREMISES(Ea occurrence) $ 50,000 MED EXP(Any one person) $ 10,000 A G27527966001 11/10/2015 11/10/2016 PERSONAL&ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 POLICY❑X PRO- JECT F—] LOC PRODUCTS-COMP/OP AGG $ 2,000,000 OTHER: $ AUTOMOBILE LIABILITYGUM $ (Ea accident) ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED BODILY INJURY(Peraccdent) $ A UTOS AUTOS HIRED AUTOS NON-OWNED $ AUTOS (Per accident) UMBRELLA LIAR X OCCUR EACH OCCURRENCE $ 5,000,000 A X EXCESS LIAB CLAIMS-MADE 627527966001 11/10/2015 11/10/2016 AGGREGATE $ 5,000,000 DED RETENTION$ $ WORKERS COMPENSATION X STATUTE ER AND EMPLOYERS'LIABILITY Y/N ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $ 1,000,000 B OFFICER/MEMBER EXCLUDED? N/A 7PJUB-5B50763-8-15 7/23/2015 7/23/2016 (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ 1,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 1,000,000 ! C Property ER07771654 5/26/2015 5/26/2016 $522,302.00 i DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Town of North Andover ACCORDANCE WITH THE POLICY PROVISIONS. Attn:Building Department AUTHORIZED REPRESENTATIVE 1600 Osgood St., Building 20,Suite 2035 //// /J North Andover MA 01845 wlt v 95��2t211 ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD {- -CRUS-ET-TS c' t11 r f OR ELECTRICIANS 4 ( , ISSUES THE FOLLowl I CENs E "�.... ' As A REG JOURNEYIAN ELECTR I CIN i - -- -- `- DANIEL J MCGRATH T�# ,. Niec r . 114 BOYLSTON ST _CL '�' seos�,i.a+ta.a+.�►t� MALDENJ KA 021$8-7931 � massachumms-Ocpatlml nt of Public Saft=ty Board sof Building Regulations and Standards Cts�lrtcti«n'�Prt�r.Ftt I.a. .F.+ttttt� 1i� �� 'C. License:CSFA-10416 - ..�.W.. Tj*and rd,,orM p„*d Nr a hw ftw$atM*cmr#Iftd r DANIEL MCOIIA'T1O=O*W i*wd"moll MrICaor>f+In 1'14 SOYLSTONSi df148 t y Comm" iM view MALDEN MA x _ DanitMaGrath Expiration Krridltl�Prsnda+prain �/ commmoner �t161201d (TaUrt Iwo—Ori a tdWt ICwrr rad tirN �*7'/rn lt�i+rnnrutiim�/�n�C'�l�nlSn�itu!!. "~ free of Consumer Affairs&Business Regulation ME IMPROVEMENT CONTRACTOR ELEC'1 RI AL UNLIMITED JOURN1EYPERSONI egistr On: 168524 Type: DANIEL)MCGRATH iration: 31v2617 Individual 114 BOYLSTON ST DANIEL MCGRATH MALDEN,MA 02148-7931 DANIEL MCGRATH 114 BOYLSTON ST LIC.,AEG NO, EFFEETIVE --u MALDEN,MA 02148 LC.0199 .1-E2 10/01/2014 09/30/2015 Undersecretary � t STATE OF CONNECTICUT STATE OF MAINE DEP?OF PROtre3510NA1.'&F AWKREGULATION EL GTRICAL(JNLLMITED C(71�1'1'RACTO[t " aLECTnrcwastDu+MiN�lf1E0ARC DANTIELJ MCGRATH LICENSE;ItMSb0W03 .. 114BOYI.SrONiST r NIALDEN,bl 02148-7911 DANIEL MCGRATH MASTER ELECTRICIAN , Ur. nrG `� IS SUED Aug 26,2013 EXPIRES Aug 31,2015 , ELC.OLOI8a5-E1 08131/2015 03/30h0J6 � S13NE) _a --- STRUCTURAL ENGINEERS December 11,2015 Sungevity 66 Franklin Street Oakland, CA 94607 Subject: Structural Certification for Installation of Solar Panels Job Number: 1500-01793 Client: Thomas Secondo-2242998 Address: 163 Olympic Lane, North Andover, MA 01845 Attn.: To Whom It May Concern A field observation of the condition of the existing framing system was performed by an audit team from Sungevity. From the field observation of the property, the existing roof structures was observed as follows: The existing roof structure consists of. e Composition Shingle(1 Layer of shingle/approximately 10 year old roof)over Roof Plywood is supported by 2x8 Rafters @ 16"o.c. at ARRAY 1/ARRAY 3. The rafters are sloped at approximately 27 degree and have a maximum projected horizontal span of 14 ft 2 in between load bearing walls. o Composition Shingle(1 Layer of shingle/approximately 10 year old roof) over Roof Plywood is supported by 2x8 Rafters @ 16"o.c. at ARRAY 2. The rafters are sloped at approximately 27 degree and have a maximum projected horizontal span of 14 ft 5 in between load bearing walls. Design Criteria: o Applicable Codes=2009 IBC,ASCE 7-05, and NDS-05 o Ground Snow Load= 55 psf o Roof Dead Load= 10.1 psf ARRAY 1/ARRAY 3; 10.1 psf ARRAY 2 j o Basic Wind Speed= 110 mph Exposure Category C o Solar modules=as indicated in attached drawings As a result of the completed field observation and design checks: o ARRAY VARRAY 3 is adequate to support the loading imposed by the installation of solar panels and modules. Therefore, no structural upgrades are required. o ARRAY 2 is adequate to support the loading imposed by the installation of solar panels and modules. Therefore, no structural upgrades are required. I certify that the capacity of the structural roof framing that directly supports the additional gravity loading due to the solar panel supports and modules had been reviewed and determined to meet or exceed the requirements in accordance with the 2009 IBC. If you have any questions on the above, do not hesitate to call. 1N OFk*tq PAUL K. ZACHER Prepared By: TRUCTURAL y PZSE, Inc. -Structural Engineers 50100 Roseville, CA �'o iST �SS�ONAL� 1 of 1 8150 Sierra College Boulevard,Suite 150 c Roseville, CA 95661 a 916.961.3960 P o 916.961.3965 wm.pise.com DocuSign Envelope ID:E7F9D52B-E971-49BE-AE59-F26FD35E5F9B sunrun EXHIBIT A SOLAR FACILITY ADDENDUM CONTRACT P87A1VRF94NDRNB THIS SOLAR FACILITY ADDENDUM CONTRACT("Addendum")is made by and between Sunrun Inc.("Sunrun")and Sungevity,Inc.("Contractor")for the design,engineering,procurement,installation,and construction of the Solar Facility described herein.This Addendum hereby incorporates, in total,the terms and conditions set forth in the Master Solar Facility Turnkey Contract("Contract"),and all schedules and exhibits thereto,executed by Sunrun and Sungevity,Inc.in March 10,2014.Capitalized terms contained herein have the meanings set forth in the Contract. SOLAR FACILITY TOTAL SOLAR PREPAID Contract Price:830,862.04 I Host Customer:Thomas C Secondo Street Address:163 Olympic Ln,North Andover,MA,01845 Rebate Level:80.00 per watt Utility:National Grid TECHNICAL SPECIFICATIONS System Size Description Rating Standard Test Condition Direct Current(STC DC kW) 9.435 I CEC Alternating Current(CEC AC kW) 8.478 Generation Equipment Photovoltaic collectors Manufacturer Model number STC DC rating Quantity Array 1 Trina Solar TSM-255PD05.05 255 W 13 Array 2 Trina Solar TSM-255PD05.05 255 W 9 Array 3 Trina Solar TSM-255PD05.05 255 W 15 Inverters Manufacturer Model number Efficiency Quantity Array 1 SolarEdge Technologies SE5000(240V)w/-ER-US or0.98 1 A-US Array 2 SolarEdge Technologies SE5000(240V)w/-ER-US or 0.98 1 A-US SE3800(240V)w/-ER-US or Array 3 SolarEdge Technologies 0.98 1 A-US Total Number of Panels: 37 Total Number of Inverters: 2 Meter Information Meter Description Manufacturer Meter selected from approved vendor list provided by Sunrun. Model number Meter selected from approved vendor list provided by Sunrun. 11/12/2015 P87A1VRF94NDRNB-A(Prepaid PPA) Page 1 oft h DocuSign Envelope ID:E7F9D52B-E971-49BE-AE59-F26FD35E5F9B sunrun EXHIBIT A r SOLAR FACILITY ADDENDUM CONTRACT SOLAR FACILITY DESIGN DIAGRAMS Attach the single-line diagram and aerial-view module layout for the Solar Facility to this document. ASSIGNMENT When transfer of the title to the Work occurs pursuant to the Contract,title to the Work shall be transferred to the Person("Assignee")designated in Exhibit A-1. MISCELLANEOUS Neither this Addendum,nor the Contract,creates any employment,agency,partnership,joint venture or other joint relationship between the Parties. Should a conflict arise between the terms of this Addendum and the terms of the Contract that cannot be reconciled,the terms of this Addendum shall govern;provided•however,agreement on a conflicting term in this Addendum shall not operate to modify the conflicting term in the Contract for future addenda executed between the Parties.This Addendum may be executed in counterparts,each of which will be deemed an original,but all of which taken together will constitute but one and the same instrument. SUNRUN INC. SUNGEVITY,INC. DocuSigned by: y DocuSiggnned by: Signat 1CD4F8CBECD74FA... -OWWR3996493... Adam Murray Zak Federer Name Name Operations Associate tho47ed'A ent Title Title 11/17/2015 11/12/2015 Date Date III 11/12/2015 P87A1VRF94NDRNB-A(Prepaid PPA) Page 2 of 2 1 2 3 // 4 5 PHOTOVOLTAIC SYSTEM SCOPE OF WORK: / SHEET INDEX PV0.0 COVER AND SITE PLAN INSTALLATION OF A SAFE AND CODE-COMPLIANT GRID-TIED SOLAR PV SYSTEM ON AN EXISTING / / PV1.0 GENERAL NOTES SYSTEM SIZE: RESIDENTIAL ROOF TOP. j /i PV2.0 ARRAY LAYOUT i AC/DC kW STC: 8.64kW\9.69kW /� / PV3.0 LINE DIAGRAM r' PV4.0 LABELS EQUIPMENT: / A /' PV5.0 DIRECTORY A PV MODULES: (38)Trina Solar TSM-255 PD05.05 / (1)SolarEdge SE5000A-US PG KEY. INVERTER(S): v0 / ---- (1)SolarEdge SE3800A-US 5 PROPERTY LINE_._ DRIVEWAY � — CONDUIT RUN Q INVERTER DRIVEWAY O SUBPANEL FENCE Q DC DISCONNECT FIRE CLEARANCE STRUCTURAL AC DISCONNECT UPGRADES I]I]JUNCTION BOX O SOLAR MODULE El MONITORING UNIT LOCATION OF(E)MSP, / Q MAIN SERVICE PANEL E) COMBINER BOX INSIDE BASEMENT Q UTILITY METER ROOF PV METER OBSTRUCTION APPLICABLE CODES: P\� Q 2014 NEC G ?�_ 2009 INTERNATIONAL CODES WITH MA AMENDMENTS /c) ROOF MOUNTED B CONDUIT, CONTRACTOR INFORMATION: TYP ARRAY 3 UNITED SOLAR ASSOCIATES MALDEN 452 PLEASANT ST. -pO MALDEN,MA 02148 O� o �� ROOF 3 v JURISDICTIONAL INFORMATION: O NORTH ANDOVER,TOWN OF 1600 OSGOOD ST. NORTH ANDOVER,MA 01845 0 NOTES TO INSTALLER: OF� �O FOR INSTALLER USE ONLY POST INSTALL SUNEYES REQUIRED? NO 1 CERTIFY THAT NO CHANGES HAVE C BEEN MADE TO THE ARRAY LAYOUT: C ,L CUSTOMER INFORMATION: PFL�y THOMAS C SECONDO 163 OLYMPIC LANE NORTH ANDOVER,MA 01845 SITE PLAN (617)694-7463/#2242998 N SCALE: N.T.S. DESIGNED BY: REV#: DATE: PV-0.0 TUSHAR.K 1 0 12/4/15 SUNGEVRYIN466 FRANNUN Si SUTE]iSONBM'D,G9/64T BY RNEWCOMB Omer—Lautlon:Seargo-Y11]994 SVI SNroI She:11111 T ESEDfUWWG, ORGT S.4NDDESIONSNETNEPROFERry OFSUNGE WlY .NOP SH LBECOREOORUSEDFORORW]TNnNVOTRERWORNOTRERTHNITHE OFICP ECTFORWHCHTHEV�BEENDEVELOKOWDH MRWRRTFNCO MW 1 2 3 4 5 SYMBOL KEY: MODULE SPECIFICATIONS NOTE: (38)Trina Solar TSW255 PD05.05 RAIL MODULES SHALL NOT BE MODULE WEIGHT: 41 ---- RAFTERS GREATER THAN 8 INCHES MODULE LENGTH: 1 64.95 ROOF ABOVE ROOF COVERING MODULE WIDTH: 39.05 ROOF 1 SPECS FIRE CLEARANCE RAFTERSIZE: 2X8 NOMINAL ® ® STRING CONFIG. RAFTER SPAN: 1 14'-2" SOLAR MODULE RAFTER SPACING: 16" STRUCTURAL UPGRADES ROOF MATERIAL: COMPOSITE SHINGLE ARRAY 1 SPECS Q SOLAR MODULE 101, NUMBER OF MODULES: 13 A MOUNT IRONRIDGE XR10 TOTAL MOD.WEIGHT(lbs): 533 A ® ® SKYLIGHT I I I I L-FOOT RACKING WEIGHT s): 101.8 ARRAY WEIGHT(Ib634.8 I ❑ 1 I I I IARRAY AREA(sqft): 229 1 _1_ 1-1® CHIMNEY I QMSE-LAG SHINGLE n 11 ' ARRAY DEAD LOAD(lbs/sgft): 2.8 I I -_ ® c PLUMBING OR ' COMPOSITE SHINGLE NUMBER OF MOUNTS: 30 ATTIC VENT I I I I I:--I---! --I - I 1 1 I LOAD PER MOUNT(lbs): 21.2 5" X 5/16"-LAG O I I 1--�-- �- —�- I I PER ARRAYAZIMUTH(-) 238 ATTIC VENT 2.5"MIN.EMBEDMENT ARRAY TILT(-) 27 SCREW FLOORS 2 2X8 NOMINAL,16 O.C. ROOF 2 SPECS ..:I..... i.......�.......�. ....i.......i......�.......�.......� .....1.......1.... .1.......1 I RAFTER SIZE: 2X8 NOMINAL 1 1 1 1 1 1 1 1 1 i r I MOUNTING DETAIL RAFTER SPAN: 14'-5" I O ( A RAFTER SPACING: 16" I 1 -f I �F $GALE: NTS ROOF MATERIAL: COMPOSITE SHINGLE ARRAY 2 SPECS I I I I NUMBER OF MODULES: 8 ARRAY 1 I CONTINUE -- - 1- -- TOTAL MOD.WEIGHT(Ibs): 328 1 I I 1 1 TO ARRAY 2 !r�� I I I I`. RACKING WEIGHT(lbs): 61.5 ROOF ( I I.....T......T.. ..1.......�....... ... G I I ... I....... I I I ARRAY WEIGHT(lbs): 389.5 Iy ARRAY AREA(sgft): 140.9 _ ARRAY DEAD LOAD(lbs/sgft): 2.8 /ARF��AY LNUMBER OF MOUNTS: 18 OAD PER MOUT(Ibs): 2162ARRAYAZIMUTH(°) 148 B8-2" 16'4" 5'-8" 2 ARRAY TILT(°) 27 g NUMBER OF FLOORS 2 ROOF 3 SPECS 1 RRAY-1 LAYOUT /3 ' E �- RAFTER SIZE: 2X8 NOMINAL SCALE: 3/16"=V-0" ARRAY RAFTER SPAN: 14'-2' ........... ......�.....�.......�........ ....�.......�..... I RAFTER SPACING: 16" I ROOF MATERIAL: COMPOSITE SHINGLE ARRAY 3 SPECS NUMBER OF MODULES: 17 TOTAL MOD.WEIGHT lbs 697 ARRAY 3 ROOF 3 o ( )'CONI __ 1I �..IIRACKING WEIGHT(Ibs): 128.7 /FR ARRARRAY WEIGHT(Ibs): 825.7 ARRAY AREA(sgft): 299.4 CONTINUE ......_ .....i. 21 I 1 1 3.. ( ( .._L.....1...__1..... ._._.L......I. ....1.......1.... .1.._._1....... .....1I I ARRAY DEAD LOAD(lbs/sqft): 2.8 ( I I I -- NUMBER OF MOUNTS: 38 I 1 1 1 I 1 I I I I LOAD PER MOUNT(Ibs): 21.7 ARRAY AZIMUTH(") 58 -1-i. NUMBER OF FLOORS 2 I 16'x^ 6'_6^i: rBRAY-2 LAYOUT 2 SCALE: 3/16"=V-0" C I 1......1....... ... l........ . . ...._ .... ...... ....... . ........... ................ 114OF1(q CUSTOMER INFORMATION: I PAUL K. -- -- _F -- -)• - I i I ZACHER 9 THOMAS C SE O 163 LANE TRUCTURAL y NORTH ANDOVER,MA 01845 6'-3" 29'_5" 50100 (617)694-7463/#2242998 RRAY-3 LAYOUT OSS/ONAL � 3 SCALE: 3/16"=1'-0" DESIGNED BY: REV#: DATE: PV-2.0 TUSHAR.K 0 12/4/15 SONGEVITYINC.B$MR NSTSUTE310ONOAND,CAQ, .'.EY.CO1.IDDet":—Laatlon:Sem,Jo-Y1a3990Bv'-51ze.t " THESE IXUWMGS.SPEgFlGTIONS.AND DEEM,N3 ARE THE PROM—OF WNGEV INC.NO PART 514YL BE CORED OR USED FOR OR N1TH NNV OTHER MW OTHER T-N THE S—FIC F—ECT FOR—THEY N—E BEEN DEVELOPED WITHOUT WRWRITTEN CONSENT 1 2 3 4 5 PHOTOVOLTAIC SYSTEM SCOPE OF WORK: SHEET INDEX INSTALLATION OF A SAFE AND CODE-COMPLIANT "1Z PV0.0 COVER AND SITE PLAN GRID-TIED SOLAR PV SYSTEM ON AN EXISTING / / PV1.0 GENERAL NOTES PV2.0 ARRAY LAYOUT RESIDENTIAL ROOF TOP. / i SYSTEM SIZE: i AC/DC kW STC: 8.64kW\9.69kW PV3.0 LINE DIAGRAM EQUIPMENT: r j % PV4.0 LABELS A DIRECTORY PV MODULES: (38)Trina Solar TSM-255 PD05.05 G /-' A 0 INVERTER(S): (1)SolarEdge SE5000A-US p' — ---- PROPERTY LINE KEY: v (1)SolarEdge SE380OA-US r� —-- CONDUIT RUN �aJ \ DRIVEWAY � p INVERTER Val ; DRIVEWAY 0 SUBPANEL FENCE Q DC DISCONNECT FIRE CLEARANCE Q AC DISCONNECT '� /� a•s. STRUCTURAL UPGRADES OO JUNCTION BOX O SOLAR MODULE O MONITORING UNIT LOCATION OF(E)MSP, Q MAIN SERVICE PANEL ❑`° COMBINER BOX E] UTILITY\� \� Q PV METER ROOF INSIDE BASEMENT OBSTRUCTION APPLICABLE CODES: Q 2014 NEC G �� 2009 INTERNATIONAL CODES WITH MA \� P' AMENDMENTS ROOF MOUNTED B `� CONDUIT, CONTRACTOR INFORMATION: B TYP ARRAY 3 UNITED SOLAR ASSOCIATES MALDEN ` 452 PLEASANT ST. MALDEN,MA 02148 O,, O �� ROOF 3 O v JURISDICTIONAL INFORMATION: O NORTH ANDOVER,TOWN OF 1600 OSGOOD ST. NORTH ANDOVER,MA 01845 0 NOTES TO INSTALLER: O C•F Z FOR INSTALLER USE ONLY POST INSTALL SUNEYES REQUIRED? NO I CERTIFY THAT NO CHANGES HAVE C BEEN MADE TO THE ARRAY LAYOUT: C L CUSTOMER INFORMATION: THOMAS C SECONDO 163 OLYMPIC LANE NORTH ANDOVER,MA 01845 SITE PLAN N (617)694-7463/#2242998 SCALE: N.T.S. DESIGNED BY: REV#: DATE: II TUSHAR.K 0 12/4/15 PV-�� SUROENTYINC.N FRNOOIN ST SUTE 310 B, 5V15NaN She:111) ]MESE ORRYANGS.SPECIFICATIONS,Plm DESM.NS nRE THE PROPERTY OF SVNOEVITV INC.NOPMTSHPLLBEUORMORU MFORORYrtTHPNY ERVroIIXO RT MV ESPECIFICP ECTFOR CHTHEYHFVEBEEND LOV DWrtI MRVIRRTENCON 1 2 3 4 5 SYMBOL KEY: MODULE SPECIFICA ONS NOTE: (38)Trina Solar TSM-255 PD05.05 ------- RAIL MODULE WEIGHT: 41 MODULES SHALL NOT BE ———— RAFTERS GREATER THAN 8 INCHES MODULE LENGTH: 64.95 ROOF ABOVE ROOF COVERING MODULE WIDTH: 39.05 ROOF 1 SPECS FIRE CLEARANCE RAFTER SIZE: 2X8 NOMINAL (D""""""'OO STRING CONFIG. RAFTER SPAN 1 14'-2" STRUCTURAL SOLAR MODULE RAFTER SPACING: 16" a UPGRADES ROOF MATERIAL: COMPOSITE SHINGLE ARRAY SPECS Q SOLAR MODULE 101, \ NUMBER OF MODULES: 13 A MOUNT TOTAL MOD.WEIGHT(Ibs): 533 A IRONRIDGE XR'10® ® I I ( I RACKING WEIGHT Qbs): 101.8 SKYLIGHT L-FOOT ARRAY WEIGHT(Ibs): 634.8 I I I I I I I ARRAY AREA(sqft): 229 ® CHIMNEY OMSE-LAG SHINGLE ARRAY DEAD LOAD(lbs/sqft): 2.8 a PLUMBING OR .1 COMPOSITE SHINGLE NUMBER OF MOUNTS: 30 ATTIC VENT I ( I I' 1 I ( 5" X 5/16"-LAG LOAD PER MOUNTQbs): 21.2 . __�__ _ I ARRAYAZIMUTH(°) 238 ATTIC VENT I I 2.5"MIN.EMBEDMENT PER SCREW NUMBER IOF FLOORS 27 -- -- -� -- -'� 2X8 NOMINAL,16 O.C. ROOF 2 SPECS I .::�.�... �.......�.......�. ....�........... .�..............� ............�.... .I.......I RAFTER SIZE: 2X8 NOMINAL MOUNTING DETAIL RAFTER SPAN: 14'-5" 10, O I I RAFTER SPACING: 16" I I I 1' t I 4 SCALE: NTS ROOF MATERIAL I COMPOSITE SHINGLE ARRAY 2 SPECS I I I I I I 1 I I I I NUMBER OF MODULES: 8 ARRAY( I CONTINUE -- - 1_ __ I TOTAL MOD.WEIGHT(Ibs): 328 I TO ARRAY 2 1 I I I RACKING WEIGHT(Ibs): 61.5 I ROOF 1 I I I I I I.....T......T.. ..j.......j....... ... Q I 1 ... I.......I.......I. ....I.... I I I ARRAY WEIGHT(Ibs): 389.5 rrii r-� ARRAY AREA(sqft): 140.9 I U I I I I LJ I I ARRAY DEAD LOAD(Ibs/sqft): 2.8 NUMBER OF MOUNTS: 18 (ARRAY 2 l LOAD PER MOUNTQbs): 21.6 I ARRAY AZIMUTH(") 148 B 8'-2" 16'-4" 5'-8" I ROOF 2 ( ARRAY TILT(') 27 B rn NUMBER OF FLOORS 2 I i ROOF 3 SPECS RRAY-1 LAYOUT CONTINUE I_ RAFTER SIZE 2X8 NOMINAL SCALE: 3/16"=V-0" FROM ARRAY( RAFTER SPAN: 14'-2" ............. .....1.....L......1......( ...�...._.�..... I I I RAFTER SPACING:1 16" I r I I`.. I I ROOF MATERIAL: COMPOSITE SHINGLE r I _ ARRAY 3 SPECS o NUMBER OF MODULES: 17 I I ( I ............�IIIIIII._........AIIII....R.......R...T...jIIIIA—...Y . O...O.�...FII^..3. 7 TOTAL Y MOD.WEIGHT)(bs): 69 70AKING WEIGHT Ob.): 128.. 7CONTINUE TO —i-+ I ARRAY WEIGHT(Ibs): 8257ARARRAY AREA(sqft): 299.4 2.8ARRAY DEAD LOAD(Ibs/sqR):/FR NUMBER OF MOUNTS: 38 LOAD PEM (bs: 21.7 ARRAY YAZIMUTH(-) 58 TILT(') 27 ....... ... 1s'-4° 6,_6" NUMBER OF FLOORS 2 � ARRY-2 LAYOUT "=1-0"AE C Z10FMqCUSTOMER INFORMATION: r PAUL THOMAS C SECONDO I I I I ZACHER 163 OLYMPIC LANE TRUCTURAL NORTH ANDOVER,MA 01845 6'-3" 29'_5" 50100 (617)694-7463/#2242998 O� 1611 T . RROAY-3 LAYOUT DESIGNED BY: REV#: DATE: SCALE: 3/16"=1'-0" PV-2.0 TUSHAR.K 0 12/4/15 SUNOEVITY INC.SS FRANg1N ET SUITE)t0--D.CA BaS07 yANEWCOMR Deter—L"mWn:SecwMo-Y1af3905Vt SNeN Slzs:11.17 THESE D—IRGS.SPECIFICATIONS,ANDDESIGNS ARE TIE PROPERTY OF EUNOEVITY INC.NO FART SHALLBE CORED OR USED FOR OR VATH ANY OTHER—OTHER THAN THESPECIFIC PROJECT FOR WHICH THEYHAVEVEEN DEVELOPED WITHOUT WR WRITTEN CONSENT 1 2 1 3 1 4 1 5 ELECTRICAL KEY: INVERTER 1 SPECIFICATIONS INVERTER 2 SPECIFICATIONS MODULE ELECTRICAL SPECIFICATIONS SOLAREDGE SE5000A-US SOLAREDGE SE3800A-US (38)Trina Solar TSM-255 PDO5.05 f1_ BREAKER RATED WATTS(EACH): 5000 RATED WATTS(EACH): 3800 SHORT CIRCUIT CURRENT psc): 8.88 �.- SWITCH AC OPERATING VOLTAGE(V): 240 AC OPERATING VOLTAGE(V): 240 OPEN CIRCUIT VOLTAGE(Voc): 38.1 SCREW TERMINAL AC OPERATING CURRENT(A): 21 AC OPERATING CURRENT(A): 16 OPERATING CURRENT(IMP): 8.37 m FUSE NUMBER OF MPPT CHANNELS 0 NUMBER OF MPPT CHANNELS 0 OPERATING VOLTAGE(VMP): 30.5 • SPLICE INVERTER EFFICIENCY: 1 0.98 INVERTER EFFICIENCY: 1 0.98 MAX SERIES FUSE RATING: 15 EARTH GROUND INTEGRATED DC DISCONNECT INTEGRATED OC DISCONNECT STC RATING: 255 (77 CHASSIS GROUND INVERTERIINPUT SPECIFICATIONS INVERTER 2 INPUT SPECIFICATIONS PTC RATING: 232 ——— GEC NOMINAL CURRENT PER STRING(Inom): 8,8 LNOMINAL CURRENT PER STRING(Inom): 11.T DESIGN CONDITIONS EGC NOMINAL VOLTAGE(Vnom): 35D NOMINAL VOLTAGE(Vnom): 350 HIGHEST 2%DB DESIGN TEMP('C): 32 MAX SYSTEM VOLTAGE(Vmax): 500 MAX SYSTEM VOLTAGE(Vmax): 500 MIN.MEAN EXTREME ANNUAL DB('C): -18 A MAX CURRENT PER STRING(Imax): 15 1 MAX CURRENT PER STRING(Imax): 15 A MAX INPUT CIRCUIT CURRENT(Imax): 30 MAX INPUT CIRCUIT CURRENT(Imax): 15 (3)#8 THWN-2 (3)#8 THWN-2 (3)#8 THWN-2 (3)#6 THWN-2 (6)#10 PV-Wire (6)#10THWN-2 (3)#10THWN-2 (1)#8 GEC (1)#8 GEC (1)#8 GEC (1)#8 GEC (1)#10 EGC (1)#10 EGC (1)#8 GEC 3/4"EMT 374"EMT 3/4'EMT 3/4"EMT FREE AIR 3/4"EMT 3/4"EMT (N)MIN.60A AC Combiner METER SUB PANEL SUPPLY SIDE CONNECTION WITH (N)SE5000A-US AC DISCONNECT, POLARIS BLOCK OR SIMILAR INVERTER W/INTEGRATED 60AMP, AC DISCONNECT, 250VAC RATED UL LISTED AND DC DISCONNECTS NON-FUSIBLE,C-H 60AMP,FUSIBLE APPROVED CONNECTOR —_————— DG222URB C-H DG222NRB 1 STRING OF 30A 2P LOCUS SOA FUSE pV 200A MAIN BREAKER 11 MODULES -AC METER OPT.CURRENT=8.01A DC v OUTPUT IL LOAD LINE LOAD LINE _______ _ __ 1 STRING OF + I 11 MODULES I(E)LOADS OPT.CURRENT=8.01A INVERTER R(E)LOADS 240V D2P XW 11fpA GO SP (3)#10 THWN-2 _ I B (1)#8 GEC 3/4"EMT B I 1 wl �L (N)SE3600A-US INVERTER W/INTEGRATED DC DISCONNECTS 1 STRING OF 20A 2PEXI GEC IRREVERSIBLY SPLICED TO i6 MODULES -AC TO STING GEC OR B NDED DIRECTLY E)USTNG GROUNDING ELECTRODE OPT.CURRENT=11.66A DC«. --OUTPUT --_- (IF A7RATINGS MIN.NEMA3R UL LISTEINVERTER BOX WITH 90'C TERMINLOCAT C C Inom=(16 x 255W)/350V=11.7A CONDUIT ELEVATION:1/2 TO 3-1/2"=22°C 38 MODULES TOTAL OPERATING VOLTAGE=350VDC(REGULATED) HIGH AMBIENT TEMPERATURE:32°C 38 x 232(PTC WATTS)x 0.98=8640 CEC WATTS CUSTOMER INFORMATION: EXTREME LOW:-18°C ROOFTOP AMBIENT TEMP(Tcorr):54°C=0.76 SE5000A-US MAX OUTPUT CURRENT=21A THOMAS C SECONDO CONDUIT FILL(Cfill):0.8 BREAKER SIZE=21A x 1.25=26.25A=>30A 163 OLYMPIC LANE SE380OA-US MAX OUTPUT CURRENT=16A NORTH ANDOVER,MA 01845 CONTINUOUS USE=Imax"1.25=15A BREAKER SIZE=16A x 1.25=20A=>20A (617)694-7463/#2242998 CONDITIONS OF USE=Imax/Tcorr/Cfill =15A/0.76/0.8=24.67A CONDUCTOR SIZE FOR 24.67ADESIGNED BY: REV#: DATE: INSTALLATION SHALL USE MIN.#10 AWG TUSHAR.K 0 12/4/15 PV-3.0 SUNGEVOYIMC.66 FRPNx11N ST SUITE 6t00AgNaD.CA 9160] BY ANEWCOMB Dme:—Lumlbn:Sem,EP-2NX965Vt Suet Siz°:11a17 THESE DRAWINGS,SPEgFIGIIONG AND DESIGNS AfiETME PROPERiv OF SUNGENTVINC.NO PART SHALL OE COPIEDORUSED FOR OR WITH ANVOTHER WORN OTHER THAN THE SPECIFlC PROJECT FOR WMg1 THEY HAVEBEEN DEVELOPED WITNOUi OUR WRITTEN CONSEM Ir1C STRU(TURAI ENGINEERS December 4, 2015 Sungevity 66 Franklin Street Oakland, CA 94607 Subject: Structural Certification for Installation of Solar Panels Job Number: 1500-01793 Client: Thomas Secondo-2242998 Address: 163 Olympic Lane, North Andover, MA 01845 Attn.: To Whom It May Concern A field observation of the condition of the existing framing system was performed by an audit team from Sungevity. From the field observation of the property, the existing roof structures was observed as follows: The existing roof structure consists of: • Composition Shingle over Roof Plywood is supported by 2x8 Rafters @ 16"o.c. at ARRAY 1/ARRAY 3.The rafters are sloped at approximately 27 degree and have a maximum projected horizontal span of 14 ft 2 in between load bearing walls. • Composition Shingle over Roof Plywood is supported by 2x8 Rafters @ 16"o.c. at ARRAY 2. The rafters are sloped at approximately 27 degree and have a maximum projected horizontal span of 14 ft 5 in between load bearing walls. Desiqn Criteria: • Applicable Codes=2009 IBC, ASCE 7-05, and NDS-05 • Ground Snow Load = 55 psf • Roof Dead Load = 10.1 psf ARRAY 1/ARRAY 3 ; 10.1 psf ARRAY 2 • Basic Wind Speed = 110 mph Exposure Category C • Solar modules=as indicated in attached drawings As a result of the completed field observation and design checks: • ARRAY 1/ARRAY 3 is adequate to support the loading imposed by the installation of solar panels and modules. Therefore, no structural upgrades are required. • ARRAY 2 is adequate to support the loading imposed by the installation of solar panels and modules. Therefore, no structural upgrades are required. I certify that the capacity of the structural roof framing that directly supports the additional gravity loading due to the solar panel supports and modules had been reviewed and determined to meet or exceed the requirements in accordance with the 2009 IBC. LIH OF so If you have any questions on the above, do not hesitate to call. qoy PAUL K. G ZACHER Prepared By: TRUCTURALCn PZSE, Inc. -Structural Engineers 50100 6/30 R.. Roseville, CA �o�SSu/OSTE NALEN�'\��� 1 of 1 8150 Sierra College Boulevard,Suite 150 • Roseville,CA 95661 • 916.961.3960 P . 916.961.3965 a, www.pzse.com TSM-DC05A.05 Honeys IN BLACK DIMENSIONS OF PV MODULE TSM-DC05A.05 ELECTRICAL DATA @STC TSM-250 TSM-255 TSM-260 TSM-265 DC05A.05 DCOSA.05 DC05A.05 DC05A.05 941 mm Peak Power Watts-PMAx(Wp) 250 255 260 265 Power Output Tolerance-PMAx(%) 0/+3 0/+3 0/+3 0/+3 o JUNCTION eox Maximum Power Voltage-VMPP(V) 29.8 30.1 30.2 30.6 NAMEPLATE Maximum Power Current-IMPP(A) 8.38 8.48 8.61 8.66 6 0 409x12 c Open Circuit Voltage-Voc(V) 38.1 38.2 38.4 38.5 INSTALLING HOLE 1 Short Circuit Current-Isc(A) 8.91 8.98 9.15 9.20 3 Module Efficiency qm(%) 15.3 15.6 15.9 16.2 E STC:Irradiance 1000 W/m',Cell Temperature 25°C,Air Mass AM1.5 according to EN 60904-3. E Average efficiency reduction of 4.5%at 200 W/m'according to EN 60904-1. E 0 3 3 ELECTRICAL DATA @ NOCT TSM-250 TSM-255 TSM-260 TSM-265 DC05A.05 DC05A.05 DC05A.05 DC05A.05 Maximum Power-PMAx(Wp) 183 186 190 194 6943GROUNDING HOLE Maximum Power Voltage-UMPP(V) 26.9 26.9 27.0 27.2 A A Maximum Power Current-IMPP(A) 6.89 6.93 7.04 7.13 iz-DMIN HOLE Open Circuit Voltage-Uoc(V) 33.8 34.6 34.8 35.0 l Short Circuit Current-Isc(A) 7.14 7.20 7.34 7.40 812mm I 180 NOCT:Irradiance at 800 W/m',Ambient Temperature 20°C,Wind Speed 1 m/s. Back View MECHANICAL DATA Solar Cells Monocrystalline 156 x 156 mm E Cell Orientation 60 cells(6 x 10) Module Dimensions 1650 x 992 x 35 mm Weight 18.6 kg �, 35mm I A-A Glass High Transparency Solar Glass 3.2 mm Backsheet Black I I Frame Black Anodized Aluminium Alloy I-V CURVES OF PV MODULE TSM-255 DC05A.05 J-Box IP 65 rated I Cables Photovoltaic Technology Cable 4.0 mm',1000 mm to.- 1 W m% Connector Original MC4 8.� m 7m 6.0° TEMPERATURE RATINGS MAXIMUM RATINGS 5.- U 4.m Nominal Operating Cell 44°C(±2°K) Operational Temperature -40 to+85°C 3.- 200W/m Temperature(NOCT)2. Maximum System 1000V DC IEC) mTemperature Coefficient of PMAx 0.41%/°K Voltage 0.00 Temperature Coefficient of Voc -0.32%/°K Max Series Fuse Rating ! 15A 0.00 10.00 20.. 30.. 40.00 Voltage(V) Temperature Coefficient of Isc 0.053%/°K WARRANTY 10 year Product Workmanship Warranty CERTIFICATION 25 year Linear Power Warranty IEC61215/EN61215 - - IEC61730/EN61730 (Please refer to product worronty for details) IEC 627162 PIG 1917/05.11 IEC 61701 DIN EN 60068-2-68 LC2 '? MCS BBA 0016 " N F"-] �.� Is PACKAGING CONFIGURATION z .© \/ Modules per box:29 pieces z I Modules per 40'container:812 pieces H E Pv-dYCLE e �p���Jcolar CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. LLLIII Il Y 1 ©2013 Trina Solar Limited.All rights reserved.Specifications included in this datasheet are subject to change without notice. Smart Energy Together ether solar ® Single Phase Inverters for North America SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ SE760OA-US/SE1000OA-US/SE1140OA-US SE3000A-US I SE380OA-US SE5000A-US SE6000A-US SE760OA-US I SE1000OA-US I SE1140OA-US OUTPUT Nominal AC Power Output 3000 3800 5000 6000 7600 9980 @ 208V 11400 VA ........................................... ................ ............... ................. ................ ................ .10000.0249Y. .................. ........... Max.AC Power Output 3300 4150 5400 @ 208V 6000 8350 10800 @ 208V 12000 VA 5450.@ 240V.. . 10950.@�4Q�. .................. ........... ............... ................ . AC Output Voltage Min:Nom:Max.(') 183-208-229 Vac . ......................................... ................ ............... ................. ................ ................ .................. .................. ........... AC Output Voltage Min:Nom:Max.(') V V V ✓ 211-240-264 Vac AC Frequency Min..Nom.-Max(') 59.3-60-60.5(with Hl country setting 57:60:60.5) Hz..... ... ............ 24 @ 208V 48 @ 208V Max.Continuous Output Current 12.5 16 25 32 47.5 A ..21.@ 240V... 42�it1 240V... ..... ................ ......... ........... ........... GFDI Threshold 1 A ........................................... .......................................................................................................................... ........... Utility Monitoring,Islanding Protection,Country Configurable Thresholds Yes Yes INPUT Maximum DC Power(STC) 4050 5100 6750 8100 10250 13500 15350W ................. ........... Transformer-less,Un rounded Yes ............ .....�........ ..................................................... ... Max. V ..........Input..........oltage....................... ...........................................................500............................................................... ...Vdc........ Nom.DC Input Voltage 325 @ 208V/350 @ 240V Vdc ......... .... I................i6�Wibg� .......... ...... 33 @ 208V Max.Input Current(2) 9.5 13 18 23 34.5 Adc ....... ................. . 15 5, 240V]................ ................ ..305(al 240V.. ..... .......... ........... Max.Input Short Circuit Current 45 Adc ........................................... .......................................................................................................................... ........... Reverse-Polarity Protection Yes .. ....................... . ........................................................ ........... Ground-Fault Isolation Detection 600kQ Sensitivity ......................................... . ......... ... ............... Maximum Inverter Efficiency 97.7 98.2 98.3 98.3 98 98 98 ............. ............... . .. . .. ...... .. ................ .................. .................. ........... CEC Weighted Efficiency 97.5 98 97.5 @ 208V 97.5 97.5 97 @ 208V 97.5 % ......................................... ................ ............... ..98.@.24QV.. ................ ................ ..975 @ 240V.. Nighttime Power Consumption <2.5 <4 W ADDITIONAL FEATURES Supported Communication Interfaces R5485:RS232,Ethernet,ZigBee(optional) . ....................................... (al ..................................... ........... Revenue Grade Data,ANSI C12.1 Optional ........................................... ......................................... ................................................................................ ........... Rapid Shutdown-NEC 2014 690.12 Functionality enabled when SolarEdge rapid shutdown kit is installed(") STANDARD COMPLIANCE SafetY................................... ........................................U L1741,U L16 99B,U L1998,CSA 22.2 ........................................ ........... Grid Connection Standards IEEE1547 ........................................... .................................................... ........ ....................................................... ........... Emissions FCC part15 class B INSTALLATION SPECIFICATIONS AC output conduit size/AWG range 3/4"minimum/16.6 AWG 3/4"minimum/8-3 AWG ................................... ......... .............................. . ...................... ........... DC input conduit size/#of strings/ 3/4"minimum/1-2 strings/ AWG ran a& 3/4"minimum/1-2 strings/16-6 AWG.............................. ................................................................................... . . ............14-6 AWG............. ........... Dimensions with Safety Switch 30.5 x 12.5 x 7.2/775 x 315 x 184 30.5 x 12.5 x 10.5/ in/ ................................ ......... ................. ..........775 x 315 x 260........ .mm.... Weight with Safety Switch............. ..........5.1.2./.23.2..........I....................54.3./.24.3 ...........88.4 40.1 Ib/kg ................... ........... Natural convection Cooling Natural Convection and internal Fans(user replaceable) fan(user ........................................... ................................................................... .replaceable). . .................................... ........... Noise .............................. 25. ....................... 50 dBA Min.-Max.Operating Temperature -13 to+140/-25 to+60(-40 to+60 version available(s)) -F/-C Rang?................................... .......................................................................................................................... ........... Protection RatingNEMA 3R ........................................... .......................................................................................................................... ........... Ill For other regional settings please contact SolarEdge support. Izl A higher current source may be used;the inverter will limit its input current to the values stated. (sl Revenue grade inverter P/N:SExxxxA-USOOONNR2(for 7600W inverter:SE7600A-US002NNR2). (4)Rapid shutdown kit P/N:SE1000-110-Sl. (s)-40 version P/N:SExxxxA-USOOONNU4(for 7600W inverter:SE7600A-US002NNU4). sunsPec //d IRONRIDGE Roof Mount System XR Rails XR10 Rail XR100 Rail XR1000 Rail Internal Splices e �. s4 II s- A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. 6'spanning capability 8'spanning capability 12'spanning capability Self-tapping screws Moderate load capability Heavy load capability Extreme load capability Varying versions for rails Clear&black anod.finish Clear&black anod.finish Clear anodized finish Grounding Straps offered Attachments f° - FlashFoot Slotted L-Feet Standoffs Tilt Legs - Y Y- - "- � Anchor,flash,and mount Drop-in design for rapid rail Raise flush or tilted Tilt assembly to desired with all-in-one attachments. attachment. systems to various heights. angle,up to 45 degrees. -§ Ships with all hardware High-friction serrated face Works with vent flashing Attaches directly to rail IBC&IRC compliant Heavy-duty profile shape Ships pre-assembled Ships with all hardware Certified with XR Rails Clear&black anod.finish 4"and 7"Lengths Fixed and adjustable Built for solar's toughest roofs. Clamps&Grounding Iron Ridge builds the strongest roof mounting system in solar.Every component has been tested to the limit and proven in extreme environments. End Clamps Grounding Mid Clamps O T-Bolt Grounding Lugs O Accessories Our rigorous approach has led to unique structural features,such as curved rails and reinforced flashings,and is also why our products are fully certified,code compliant and backed by a 20-year warranty. - g„ Ik Strength Tested PE Cert�edIILI�I All Components evaluated for superior re Pre-stamped engineering letters Slide in clamps and secure Attach and ground modules Ground system using the Provide a finished and tip strUCtural perfOrmanCe. available in most states. modules at ends of rails. in the middle of the rail. rail's top slot. organized look for rails. Mill finish&black anod. Parallel bonding T-bolt Easy top-slot mounting Snap-in Wire Clips Sizes from 1.22"to 2.3" Reusable up to 10 times Eliminates pre-drilling Perfected End Caps 167 Class A Fire Rating Design Software Optional Under Clamps Mill&black stainless Swivels in any direction UV-protected polymer Certified to maintain the fire resistance Is Online tool generates a complete bill of rating of the existing roof. materials in minutes. Free Resources Design Assistant 10♦4 NABCEP Certified Training Integrated Grounding 20 Year Warranty =- Go from rough layout to fully ► Earn free continuing education credits, Fe engineered system.For free. ®� while learning more about our systems. UL 2703 system eliminates separate Twice the protection offered by ® module grounding Components. COmpetitOfS. - Go to IronRidge.com/rm ♦ Go to IronRidge.com/training TSM-DC05A.05 Honeyv IN BLACK DIMENSIONS OF PV MODULE TSM-DC05A.05 TSM-250 TSM-255 TSM-260 TSM-265 ELECTRICAL DATA @STC % DC05A.05 DCOSA.05 DC05A.05 DC05A.05 941 mm Peak Power Watts-PMAx(Wp) 250 255 260 265 JUNCTION o Power Output Tolerance-PMA%(%) 0/+3 0/+3 0/+3 0/+3 o sox Maximum Power Voltage-VMPP(V) 29.8 30.1 30.2 30.6 NAMEPLATE o �Maximum Power Current-LNPF(A) 8.38 8.48 8.61 8.66 wsTnulNGHOLE „ Open Circuit Voltage-Voc(V) 38.1 38.2 38.4 38.5 Short Circuit Current-Isc(A) 8.91 8.98 9.15 9.20 3 Module Efficiency qm(%) 15.3 15.6 15.9 16.2 E STC:Irradiance 1000 W/m',Cell Temperature 25°C,Air Mass AMl.5 according to EN 60904-3. E 10Average efficiency reduction of 4.5%at 200 W/m°according to EN 60904-1. 0 3 10 3 ELECTRICAL DATA @ NOCT TSM-250 TSM-255 TSM-260 TSM-265 DC05A.05 DC05A.05 DC05A.05 DC05A.05 Maximum Power-PMAx(Wp) 183 186 190 194 1 Maximum Power Voltage-UMPY(V) 26.9 26.9 27.0 27.2 &0 4.3 GROUNDING HOLE i OflAIN HOLE A A Maximum Power Current-IMP?(A) 6.89 6.93 7.04 7.13 1 Open Circuit Voltage-Uoc(V) 33.8 34.6 34.8 35.0 Short Circuit Current-Isc(A) 7.14 7.20 7.34 7.40 812mm 180 NOCT:Irradiance at 800 W/m',Ambient Temperature 20°C,Wind Speed 1 m/s. Back View MECHANICAL DATA Solar Cells Monocrystalline 156x 156 mm E Cell Orientation 60 cells(6 x 10) Module Dimensions 1650 x 992 x 35 mm Weight 18.6 kg I 35mm A-A Glass High Transparency Solar Glass 3.2 mm Backsheet Black Frame Black Anodized Aluminium Alloy I-V CURVES OF PV MODULE TSM-255 DC05A.05 1-Box IP 65 rated Cables Photovoltaic Technology Cable 4.0 mm',1000 mm to.- w m, Connector Original MC4 g00 8.00 m _740 < .' 5.� TEMPERATURE RATINGS MAXIMUM RATINGS w J 4.' Nominal Operating Cell 44°C(±20K) Operational Temperature -40 to+85°C 3.'0 20OW/mz Temperature(NOCT) Maximum System 1000V DC(IEC) I Temperature Coefficient of PMAx 0.41%/°K Voltage o.. 0.°J 10.00 20.°D 30.40 40.°J Temperature Coefficient of Voc -0.32%/°K Max Series Fuse Rating 15A Voltage(v) Temperature Coefficient of Isc 0.053%/°K WARRANTY 10 year Product Workmanship Warranty CERTIFICATION 25 year Linear Power Warranty IEC61215/EN61215 - - - IEC61730/EN61730 (Please refer to product warranty for details) IEC 627162 PfG 1917/05.11 IEC 61701 DIN EN 60068-2-68 LC2 MCS BBA 0016 n I PACKAGING CONFIGURATION z Modules per box:29 pieces z WL Modules per 40'container:812 pieces E PV CYCLE �o��s® CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. olar ©2013 Trina Solar Limited.All rights reserved.Specifications included in this datasheet are subject to change without notice. Smart Energy Together ill G solar ® Single Phase Inverters for North America SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ SE760OA-US/SE1000OA-US/SE1140OA-US SE3000A-US I SE380OA-US I SE5000A-US I SE6000A-US I SE760OA-US I SE10000A-US I SE1140OA-US OUTPUT Nominal AC Power Output 3000 3800 5000 6000 7600 9980 @ 208V 11400 VA ........................................... ................ ............... ................. ................ ................ .10000,V240V. .................. ........... Max.AC Power Output 3300 4150 5400 @ 208V 6000 8350 10800 @ 208V 12000 VA 240V.. ................ ................ .10950,@ 240V. .................. ........... AC Output Voltage Min:Nom:Maxltl 183-208-229 Vac ........................................ ................ ............... ................. ................ ................ .................. .................. ........... AC Output Voltage Min-N om.-Maxltl 211-240 ..............264.....Vac........................ ................ ............... ................. ................ ................ .................. .................. ........... AC Frequency Min.;Nom:Max!tl 59.3-60-60.5(with HI country setting 57:60;60.5) Hz .. ............ . .. 24 @ 208V 48 @ 208V . ........ ....... ... Max.Continuous Output Current 12:5 16 25 32 47.5 A ........................................... . ..21�a 240V ..42.e,240V... .................. ........... ..GFDI.Threshold 1 A ..... ................................... .......................................................................................................................... ........... Utility Monitoring,Islanding Protection,Country Configurable Thresholds Yes Yes INPUT Maximum DC Power(STC) 4050 5100 6750 8100 10250 13500 15350 W ........................................... ................ ............... ................. ................ ................ .................. .................. ........... Transformer-less,U. rounded Yes Max.Input Voltage 500 Vdc ........................................... .......................................................................................................................... ........... Nom.DC Input Voltage II 325 @ 208V/350 @ 240V18 Vdc Max.Input Current(2) ..... ... ...... 9.5. 1......1 ...............(.......23.......I..30 5 @20 OV..I.... 34.5.... Adc ... Max.Input Short Circuit Current45 Adc ........................................... .......................................................................................................................... Reverse:Polarity Protection Yes Ground-Fault Isolation Detection 600kQ Sensitivit ........................................... ................ ...............1-6, .............. ................ ................ .................. .................. ........... Maximum Inverter Efficiency.......... .....97.7...... .....98.2..... . ...98:3...... .....98.3..... ......98...... .......98........ .......98........ .... ..... CEC Weighted Efficiency 97.5 98 7.5 @ 208V 97.5 97.5 97 @ 208V 97.5 ........................................... ................ ............... ..9$.�°.240V.. ................ ................ ... 240V.. .................. ........... Nighttime Power Consumption <2.5 <4 W ADDITIONAL FEATURES Supported Communication Interfaces RS485,RS232,Ethernet,ZigBee(optional) ........................................... .........................................................p......1......................................................... ........... Revenue Grade Data,ANSI C12.1 0 tional ........................................... ......................................... ................................................................................ ........... Rapid Shutdown—NEC 2014 690.12 Functionality enabled when SolarEdge rapid shutdown kit is installed(" STANDARD COMPLIANCE Safety U L1741................. ............ U L1699B:U L1998,CSA 22:2 ............ ......... Grid Connection Standards IEEE1547 ........................................... .......................................................................................................................... ........... Emissions FCC part15 class B INSTALLATION SPECIFICATIONS AC output conduit size/AWG range 3/4."minimum/16;6 AWG 3/4"minimum/8-3 AWG ................................... . ....... .............................. ..................................... ........... DC input conduit size/#of strings/ 3/4"minimum/1-2 strings/ 3/4"minimum/1-2 strings/16-6 AWG AWG,ranAq............................. . ............14;6 AWG ........ ................................................................................... . ............. ... Dimensions with Safety Switch 30.5 x 12.5 x 7.2/775 x 315 x 184 30.5 x 12.5 x 10.5/ in/ (HxWxD)................................ . ....... ............ ....... .•. •• ........775 x 315 x 260........ m .m .... ............. Wei�htwithSafetySwitch ..........51.2/232,,.,.,.,,,1..............,...........54:7./24.7.. ................ ............88:4 401,,.,..,,,,,, Ib/,kg.., Natural convection Cooling Natural Convection and internal Fans(user replaceable) fan(user ........................................... ................................................................... .replaceable). ..................................... ........... Noise <25 <50 dBA ........................................... ................................................................. . ...................................................... ........... Min.-Max.Operating Temperature Ran a :13 to+140/ 25 to+60(-40 to+60 version available(')) 'F/'C ......g........................I........... . ............................................................................. ........... Protection RatingNEMA 3R . ........................................... .......................................................................................................................... ........... For other regional settings please contact SolarEdge support. A higher current source may be used;the inverter will limit its input current to the values stated. Revenue grade inverter P/N:SExxxxA-USOOONNR2(for 7600W inverter:SE7600A-U5002NNR2). Rapid shutdown kit P/N:SE1000-RSD-Sl. (5)d0 version P/N:SExxxxA-USOOONN1.14(for 7600W inverter:SE7600A-US002NNU4). sunsPec � I IRONRIDGE Roof Mount System XR Rails XR10 Rall XR100 Rail XR1000 Rail Internal Splices e A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. 6'spanning capability 8'spanning capability 12'spanning capability Self-tapping screws Moderate load capability Heavy load capability Extreme load capability Varying versions for rails Clear&black anod.finish Clear&black anod.finish Clear anodized finish Grounding Straps offered Attachments _ t FlashFoot Slotted L-Feet Standoffs Tilt Legs _ Anchor,flash,and mount Drop-in design for rapid rail Raise flush or tilted Tilt assembly to desired with all-in-one attachments. attachment. systems to various heights. angle,up to 45 degrees. ! Ships with all hardware High-friction serrated face Works with vent flashing Attaches directly to rail IBC&IRC compliant Heavy-duty profile shape Ships pre-assembled Ships with all hardware Certified with XR Rails Clear&black anod.finish 4"and 7"Lengths Fixed and adjustable Built for solar's toughest roofs. Clamps&Grounding Iron Ridge builds the strongest roof mounting system in solar.Every component has been tested to the limit and proven in extreme environments. End Clamps Grounding Mid Clamps O T-Bolt Grounding Lugs(E) Accessories Our rigorous approach has led to unique structural features,such as curved rails and reinforced flashings,and is also why our products are fully certified,code compliant and backed by a 20-year warranty. , - Strength Tested PE Certified LLhk Alstructural All components evaluated for superior Pre-stamped engineering letters Slide in clamps and secure Attach and ground modules Ground system using the Provide a finished and performance. Ral available in most states. modules at ends of rails. in the middle of the rail. rail's top slot. organized look for rails. Mill finish&black anod. Parallel bonding T-bolt Easy top-slot mounting Snap-in Wire Clips Sizes from 1.22"to 2.3" Reusable up to 10 times Eliminates pre-drilling Perfected End Caps ® Class A Fire Rating Design Software Optional Under Clamps Mill&black stainless Swivels in any direction UV-protected polymer Certified to maintain the fire resistance Online tool generates a complete bill of rating of the existing roof. materials in minutes. Free Resources ________ _ Deslgn Assistant 10 A 4 NABCEP Certified Training Integrated Grounding 20 Year Warranty - Go from rough layout to fully ♦ ► Earn free continuing education credits, engineered system.For free. A�� while learning more about our systems. UL 2703 system eliminates separate Twice the protection offered by t ♦ Go to IronRidge.comltraining FQF Go to IronRidge.comlrm module grounding components. competitors. 1