Loading...
HomeMy WebLinkAboutBuilding Permit #Exception - 17 EMPIRE DRIVE 5/1/2018 I I MAScheck COMPLIANCE REPORT I I Massachusetts Energy Code I Permit # I MAScheck Software Version 2.01 Release 2 I I I I Checked by/Date I I CITY: North Andover STATE: Massachusetts HDD: 6322 CONSTRUCTION TYPE: 1 or 2 Family, Detached HEATING SYSTEM TYPE: Other (Non-Electric Resistance) DATE: 8-21-2012 DATE OF PLANS: 8/8/09 TITLE: The Waverly PROJECT INFORMATION: Orchard Village Lot 28, #17 Empire Drive N.Andover, MA 01845 COMPANY INFORMATION: Orchard Village, LLC Messina Development Co. , Inc. COMPLIANCE: PASSES Required UA = 592 Your Home = 336 Area or Cavity Cont. Glazing/Door Perimeter R-Value R-Value U-Value UA ------------------------------------------------------------------------------- CEILINGS 1232 38 . 0 0 . 0 37 WALLS: Wood Frame, 16" O.C. 2773 20. 0 0.0 164 BSMT: Conc. 8 .0 ' ht/7. 0' bg/0.0' insul 0 0.0 0.0 0 GLAZING: Windows or Doors 283 0.350 99 DOORS 70 0.000 0 FLOORS: Over Unconditioned Space 1105 30.0 0. 0 36 HVAC EQUIPMENT: Furnace, 96.0 AFUE HVAC EQUIPMENT: Air Conditioner, 13. 0 SEER ------------------------------------------------------------------------------- COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the requirements of the Massachusetts Energy Code. The heating load for this building, and the cooling load if appropriate, has been determined using the applicable Standard Design Conditions found in the Code. The HVAC equipment selected to heat or cool the building shall be no greater than 1250 of the design load as specified in Sections 780CMR 1310 and J4 . 4 . Builder/Designer Date Massachusetts Energy Code MAScheck Software Version 2. 01 Release 2 The Waverly DATE: 8-21-2012 Bldg. l Dept. l Use I I CEILINGS: [ ] I 1. R-38 Comments/Location I WALLS: [ ] I 1. Wood Frame, 16" O.C. , R-20 Comments/Location I BASEMENT WALLS: [ ] I 1. Conc. 8 .0' ht/7.0 ' bg/0.0' insul, R-0 (uninstilated) Comments/Location I WINDOWS AND GLASS DOORS: [ ] I 1. U-value: 0.35 For windows without labeled U-values, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments/Location I � DOORS: [ ] I 1. U-value: 0 I Comments/Location I FLOORS: [ ] I 1. Over Unconditioned Space, R-30 Comments/Location I I HVAC EQUIPMENT: [ ] I 1 . Furnace, 96.0 AFUE or higher Make and Model Number [ ] I 2. Air Conditioner, 13.0 SEER or higher Make and Model Number I I AIR LEAKAGE: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. When installed in the building envelope, recessed lighting fixtures I shall meet one of the following requirements: I 1. Type IC rated, manufactured with no penetrations between the I inside of the recessed fixture and ceiling cavity and sealed or I gasketed to prevent air leakage into the unconditioned space. 2 . Type IC rated, in accordance with Standard ASTM E 283, with no I more than 2 .0 cfm (0. 944 L/s) air movement from the the I conditioned space to the ceiling cavity. The lighting fixture I shall have been tested at 75 PA or 1.57 lbs/ft2 pressure i difference and shall be labeled. I VAPOR RETARDER: [ ] I Required on the warm-in-winter side of all non-vented framed I ceilings, walls, and floors. I I MATERIALS IDENTIFICATION: [ ] I Materials and equipment must be identified so that compliance can I be determined. Manufacturer manuals for all installed heating I and cooling equipment and service water heating equipment must be I in and provided. Insulation R-values, glazing U values, and heating g I cooling equipment efficiency must be clearly marked on the building I plans or specifications. I DUCT INSULATION: [ ) I Ducts shall be insulated per Table J4. 4.7. 1. I I DUCT CONSTRUCTION: [ ] I All accessible joints, seams, and connections of supply and return I ductwork located outside conditioned space, including stud bays or I joist cavities/spaces used to transport air, shall be sealed I using mastic and fibrous backing tape installed according to the I manufacturer's installation instructions. Mesh tape may be I omitted where gaps are less than 1/8 inch. Duct tape is not I permitted. The HVAC system must provide a means for balancing I air and water systems. I TEMPERATURE CONTROLS: [ ] I Thermostats are required for each separate HVAC system. A manual I or automatic means to partially restrict or shut off the heating I and/or cooling input to each zone or floor shall be provided. I I HVAC EQUIPMENT SIZING: [ ] I Rated output capacity of the heating/cooling system is I not greater than 125% of the design load as specified I in Sections 780CMR 1310 and J4 .4. i I SWIMMING POOLS: [ ] I All heated swimming pools must have an on/off heater switch and I require a cover unless over 20%' of the heating energy is from I non-depletable sources. Pool pumps require a time clock. ' I HVAC PIPING INSULATION: [ ] I HVAC piping conveying fluids above 120 F or chilled fluids I below 55 F must be insulated to the following levels (in. ) : I I PIPE SIZES (in. ) HEATING SYSTEMS: TEMP (F) 2" RUNOUTS 0-1" 1.25-2" 2 .5-4" Low pressure/temp. 201-250 1. 0 1.5 1.5 2. 0 I Low temperature 120-200 0.5 1. 0 1 .0 1. 5 I Steam condensate any 1.0 1. 0 1.5 2. 0 COOLING SYSTEMS: I Chilled water or 40-55 0.5 0. 5 0.75 1.0 I refrigerant below 40 1. 0 1 .0 1.5 1.5 I CIRCULATING HOT WATER SYSTEMS: [ ] I Insulate circulating hot water pipes to the following levels (in. ) : I PIPE SIZES (in. ) NON-CIRCULATING I CIRCULATING MAINS & RUNOUTS I HEATED WATER TEMP (F) : RUNOUTS 0-1" I 0-1.25" 1.5-2.0" 2 . 0+" i 170-180 0. 5 I 1.0 1.5 2 . 0 I 140-160 0.5 I 0.5 1.0 1 . 5 100-130 0.5 I 0. 5 0.5 1 .0 I ----NOTES TO FIELD (Building Department Use Only) ------------------------- i i LOT 29 18.3' L=13.5 116.2' 26.9' LOT28F ,- FND. EL.274 8' , -r < cper 13.4' 7 \/ LOT 2/ vCHOFly9ss 02��MICHAEL 9�ti 0 J. SERGI 1 v No.33191 gROFESSpaPy SURVE0404 FOUNDATION LOCA TION THIS DR4WfiVG SHALL NOTBEUSED BY774ECLIENTFORANY PURPOSE07MER7HANTHATOU7LNED ABOVE,EXCEPTWITH 7HEWRl77ENPERMISSION OFCHR677ANSEN&SERGI INC CLIENT• ORCHARD VILLAGE, LLC FVR7HERMORE7MSDRAWNGIS7HECOPVRIGHTED PROPERTY OFCHRISBAIYSEN&SERGI INC.AND ANY UNAUTHORMED USE IS MIS CERTIFICA770NISMADEANDLIMITED TOTHEABOVECLIENT PROH/Bf7ED-CHRIST14NSIW&SERGI TAKES NORESPONS/BIL/TY FOR THE TH LOCATION.• 17EMPIREDR. NORTHANDOVER,MA. INFORMA770�N�EDHEEREON.OF IS DRAWINGORANY DA TE'8/15/12 SCALE.'1~30' BASED ON SCALED DA TAONLYTHE PR/MARYS7RUC7URE SHOWN IS NOTLOCA7ED INA ROOD HAZARD ZONEAS SHOWN ON FEMA ROW INSURANCE R47E MAP COMMLWTYNQ 250098 0008C DA7El6W9W2OM=X ff; " PROFESSIONAL ENGINEERS& LAND SURVEYORS } CHRIS TIANSEN 8, SERGI, INC. z 160 SUMMER STREET, HAVERHILL,MASSACHUSETTS 01830 WWW.CSI-ENGR.COM TEL. 978-373-03 10 FAX 978-372-3960 D WG.NO.:06029.001.047