Loading...
HomeMy WebLinkAboutBuilding Permit #202-2016 - 170 PLEASANT STREET 8/17/2016 ♦ +. NORTH - k.. Orf ST LlD ib q�O BUILDING PERMIT 3r tie oL � Z TOWN OF NORTH ANDOVER APPLICATION FOR PLAN EXAMINATION ,40,�0" Permit NO:_-1 � Date Received 09, �9SSgc►+us���� Date Issued: ��( NIPORTANT: A221icant must complete all items on this page LOCATION 170 Pleasant St Print PROPERTY OWNERAlberto Sombrado Print MAP NO: 070 PARCEL: 2 d ZONING DISTRICT: Historic District yesno Machine Shop Village yes no TYPE OF IMPROVEMENT PROPOSED USE Residential Non- Residential ❑ New Building ❑One family ❑Addition ❑Two or more family ❑ Industrial ❑Alteration No. of units: ❑ Commercial ❑ Repair, replacement ❑Assessory Bldg ❑ Others: ❑ Demolition ❑Other ❑ Septic ❑Well ❑ Floodplain ❑Wetlands ❑ Watershed District ❑ Water/Sewer Installation of a roof mounted solar array. 7 7,Z Identification Please Type or Print Clearly) OWNER: Name: Alberto Sobrado Phone: 978.335.6536 Address: 170 Pleasant St North Andover MA 01845 CONTRACTOR Name: Phone: 603.304.5035 Twin State Sun *` Address: Supervisor's Construction License: Exp. Date: Home Improvement License: Exp. Date: ARCHITECT/ENGINEER TLH Consulting LLC Phone:978.362.1804 Address: 505 Middlesex Turnpike Billerica MA 01821 Reg. No. 41433 FEE SCHEDULE.BULDING PERMIT.$12.00 PER$1000.00 OF THE TOTAL ESTIMAED COST BASED ON$125.00 PER S.F. Total Project Cost: $ o2 Q Q FEE: $ 1161 Check No.: Receipt No.: 2_c�--i`-! NOTE: Persons contracting wi �unegistered contractors do not have access to th j Signature of Agent/Owner/ /`� Signature of contra ..We Plans Submitted ❑ Plans Waived ❑ Certified Plot Plan ❑ Stamped Plans ❑ f TYPE OF SEWERAGE DISPOSAL Public Sewer ❑ Tanning/Massage/Body Art ❑ Swimming pools ❑ Well ❑ Tobacco Sales ❑ Food Packaging/Sales ❑ Private(septic tank,etc. ❑ Permanent Dmnpster on Site ❑ f THE FOLLOWING SECTIONS FOR OFFICE USE ONLY INTERDEPARTMENTAL SIGN OFF - U FORM PLANNING & DEVELOPMENT Reviewed On Signature_ COMMENTS CONSERVATION Reviewed on Siqnature COMMENTS HEALTH Reviewed on Signature COMMENTS Zoning Board of Appeals: Variance, Petition No: Zoning Decision/receipt submitted yes Planning Board Decision: Comments Conservation Decision: Comments Water& Sewer Connection/S nature&Date Driveway Permit - DPW Town Engineer: Signature: _ . FIREIDEPAR®TMENT Temp Dump - "` . 384 Osgood Stre _ Ster Oni5i ►yes _ _ flOt r .. . et Fire1D1epartment_jture/date, COMMENTS.. -- _ t Dimension Number of Stories: Total square feet of floor area, based on Exterior dimensions. Total land area, sq. ft.: ELECTRICAL: Movement of Meter location, mast or service drop requires approval of Electrical Inspector Yes No DANGER ZONE LITERATURE: Yes No MGL Chapter 166 Section 21A—F and G min.$100-$1000 fine NOTES and DATA— (For department use) ❑ Notified for pickup Call Email 1 Date Time Contact Name Doc.Building Pennit Revised 2014 Building Department The following is a list of the required forms to be filled out for the appropriate permit to be obtained. Roofing, Siding, Interior Rehabilitation Permits Building Permit Application Workers Comp Affidavit Photo Copy Of H.I.C. And/Or C.S.L. Licenses 4. Copy of Contract Floor Plan Or Proposed Interior Work �. Engineering Affidavits for Engineered products OTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit p Addition Or Decks Building Permit Application Certified Surveyed Plot Plan Workers Comp Affidavit Photo Copy of H.I.C. And C.S.L. Licenses Copy Of Contract Floor/Cross Section/Elevation Plan Of Proposed Work With Sprinkler Plan And Hydraulic Calculations (If Applicable) Mass check Energy Compliance Report (If Applicable) Engineering Affidavits for Engineered products OTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit New Construction (Single and Two Family) 4 Building Permit Application 4 Certified Proposed Plot Plan Photo of H.I.C. And C.S.L. Licenses • Workers Comp Affidavit • Two Sets of Building Plans (One To Be Returned) to Include Sprinkler Plan And Hydraulic Calculations (If Applicable) Copy of Contract 2012 IECC Energy code Engineering Affidavits for Engineered products OTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg. Permit In all cases if a variance or special permit was required the Town Clerks office must stamp the decision from the Board of Appeals that the appeal period is over. The applicant must then get this recorded at the Registry of Deeds. One copy and proof of recording must be submitted with the building application Doe:Building Permit Revised 2014 Location No.oZ 6d —a Date ZS i • - TOWN OF NORTH ANDOVER S t EI) . • Certificate of Occupancy $ Building/Frame Permit Fee $ .. Foundation Permit Fee $ 9 Other Permit Fee $ TOTAL $ Check# PAL"- G i j�. Building Inspector NORT1i Town of 1 E 1, Andover O - 0 No. a C, o h ver, Mass, S COC NIC Kl WICK y1. �d p04ATED S U BOARD OF HEALTH Food/Kitchen PER.MT L D Septic System THIS CERTIFIES THAT ........ *;6 � ..... .... BUILDING INSPECTOR .......... ... ..............................�........................ .............................. �I has permission to erect .......................... buildings on Foundation 1 .... ..�� ...�^. ...� Rough oto be occupied as .... L. ... `'.". ........ �F�41 ................... .t ... .............................. Chimney provided that the person accepting this permit shall in every respect conform to the terms of the application Final on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection,Alteration and Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR VIOLATION of the Zoning or Building Regulations Voids this Permit. Rough Final PERMIT EXPIRES IN 6 MONT S ELECTRICAL INSPECTOR UNLESS CONSTRU TS Rough Service ................. ............................................................. Final BUILDING INSPECTOR GAS INSPECTOR Occupancy Permit Required to Occupy Building Rough Display in a Conspicuous Place on the Premises — Do Not Remove Final No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. Burner Street No. Smoke Det. r TLH CONSULTING, LLC STRUCTURAL ENGINEERING SERVICES 505 Middlesex TPK Unit 14 Billerica, MA 01821 Phone-- (978) 362-1804 Mobile — (978) 406-5726 July 6,2015 Brian Roy Big Sky Renewable Energy LLC 6 Green Street Hooksett,NH 03106 Re: Existing Roof Framing Analysis 170 Pleasant Street, North Andover,MA 01845 TLHC Project# 150702 Dear Brian: On July 2, 2015 TLH Consulting (TLHC) visited the site referenced above. The purpose of the visit was to observe the existing roof rafters in the area where the proposed solar array is planned to be located. This information was used to determine if the existing rafters have enough reserve capacity to support the new proposed solar array. TLHC performed a structural analysis of the existing roof framing members. The analysis was based on our measurements and observations, the 2009 International Building Code and the Massachusetts Amendment. In addition we used the proposed solar product data provided by Big Sky Renewable Energy LLC. The analysis was conducted on a single story commercial space with two wings. The existing roof rafters for the doctor's office wing are 2x4 wood members spaced at 24"on center; the waiting room wing are 2x6 wood members spaced at 20" on center. It is our opinion 1x6 wood members should be added to the waiting room wing connecting joists to increase stability. See the attached sketch for additional information Based on our review, a new solar array adds approximately 2.1 pounds per square foot (PSF) of additional load to the roof rafters on one side of the roof. It is our opinion the existing roof rafters have enough reserve capacity to accommodate the additional loads associated with the new array. The loads we used for analysis were based on the 2009 International Building Code along with the Massachusetts Amendments. The code indicates the ground snow for North TLN CONSULTING STRUCTURAL ENGINEERING SERVICES Page No. Description of Calculation: Job No. 1511701- Job Name. Date Calc'd by Scale of Sketch (if applicable): Chk'd by f 0 : I , I ' • r 1 - I f.. + L I � ' I I � ' I. .i. : r 1 i I , I t r Ll) 1 i ! ! _, f- I 1 I } 1 i I � I : 1 77 I : �' I 1 , I F . I ! I f ... SIt i f .. .PLAN Vf inf :0 F' P,DU9 • i f Andover, MA is 55 PSF and the wind velocity is 110 miles per hour. This information might be helpful for the array design. Thanks for the opportunity to provide our services to you. If you have any questions please feel free to call us at(978) 362-1804. Sincerely, 01 C HEDLY STRUCTURAL No.41433 Todd Hedly, P.E. CC. I ' file O,� CJST� SI�NAIL ��. C� Attachment. FS I if POWER PURCHASE AGREEMENT email . Twin State Sun, LLC P.O.Box 1855,New London,NN 03257 • 603-304-5035 This Sales Agreement(the"Agreement")is made day of J111+v �'- BETWEEN:Twin State Sun,LLG(the"Seller/") AND: (Name) �'_ 24 de 1 l _ _ _ _ __(the"Customer") l 7i� .� y_�iI t { ADDRESS _ _ _. 1 CnYrtaA>i STATE Z?C= :f ti':'c.-'..P aLi r r ,.E 5ER 1,1 MatEnai 5.1 Sero.c high quaRy cetfi;:d panes �'Bu ding perm t eq {aro cost rci�de�i in this after i��'` String or mScro ^�erters rr:e'r^sr agF ass'gn�d{o your prc;ect l 1Nutrg and Vectnc hardware ::^ctico box.I ghtr'ng arrestor .1 r' Sh. , , Mount system pp g cc 1s.. jded ^th's o,.er Ut fty grade meter `e/a^n_caG tees 2.1 Eng:ne�nrg and Srmu.ation #// stem me stors? �Z 'Site assessment After sales S�',ce and fro''At,est;wirg Shad^g analysis Dace ai an r 3.1 Inst n r .�-dfar.�, g ;c�a.-del Or t;;,,drg perm<t request �Stat:3tla�Of'he Sa�n�P`(p3^e S !he 4s pprc.!aea fc••^sta:.aton. lnstaiiatwn t r ^ o .he� t 3 sy5:em L,✓ Bectncai work twirag,cornect^n of,.,.^ngi 7.t Exc:,rsons 4.1 Reg:r)atory Support Ar,j other ser:.ce that caes ict appear;n this contract. „��'' Ass:starce tf-augh a: phases of the process Federal Tax Credit 5 State Tax Credit SREC Applicatia^ i ROOF MO[VIT PV SOLAR SYSTEM f � � R POWER PURCHASE AGREEMENT ' 1�1 .'J /�}ir j'<'t.'r rl C..✓t C� nt.{G ? �t t/. .%` r �! ti ,:(��is t n f,A,*b`V ir4/;,,.rAf� i PER WATT ACCEPTANCE / r This contracj dcinsti{ntes the, lire agreem and there are no further items or provisions,either o€a!o€otberatiee l..' I I y i rFry t i am - j3 h Yourhts Under the Massachusetts Consumer Protection rotect' !on Lave,General tew Improvement Contractors Law (MGL chapter 142A) are set out in the Awa1 on the reverse of this Agreement. By Signing:you certify that the information contained herein is true You au#w-ze us to make' is1t�Cort�ertting reportng agency to furn,sh credit information to us.Ycu cornet t to the use and retease of this k1>bMj,*n bytrs you e+ the Graf Conditions(Annex t)on the reverse side of this Agreement,atul the terms Of our Npilaq�Wq {}S 3 copy of the Agreement- 4 - - . - r4 I 0 CERTIFICATE OF LIABILITY INSURANCE 06/25/2"w0015 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the cerif late holder Is an ADDITIONAL INSURED,the policy(les)must be endorsed. H SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement A statement on this ceRHiale don not confer rights to the certificate holder in lieu of such endorsement(s). P12O0UCER Paychex Insurance Agency,Inc. ft",I"w""`°AQe" 150 Sawgrass Drive PHONE 7"i No• EMAL Rochester,NY 14620 877-266-6850 INSURER(S)AFFORDING COVERAGE NAI:e INSURER A:Serrlmd hnraenee Ca00a0Y INSURED RISI/RER 8:Hadfwd Fire d hs Comdidaz d AlfdiNn TWIN STATE SUN LLC RISURERC: 101 MURRAY POND ROAD INSURERD: NEW LONDON,NH 03257 INSRERS: INSURER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. ILTR NSR A POLICY TYPE OF INSURANCE POUCY NUMBER MM EFF M UNITS A GENERAL LIABILITY X I EACH OCCURRENCE f 1.000.000 ) COMMERCIAL GENERAL LWBAITY f 1,000.000 cwMSMADE 0 occuR76SBU1461 06122/2015 0612212016 MFJ)E"P eA° :+o.DOD _ )PERSONAL&ADV INJURY S+-QW.000 I GENERAL AGGREGATE S2.000.000 -91 ENI. COMP/ OP UNIT APPLIES PER: PRODUCTS-COMP AGG f 2000.000 ...POLICY %R81Fi LOC f AUTOMOBILE LIABILITY ao[Itlwt ANYAUTO I BODILY INJURY(P.PM ) f ALL OWNEDSCHEDULED +SoOLYINARYWwamidwt) S AUTOS AUTOS f HIRED AUTOS AUTOS PROPERTY DAMAGE _. f UMBRELLA L1Ae OCCUR I EACH OCCURRENCE f EACESS UAB CWMS#IADE AGGREGATE S DED RETENTION SS WORKERS COMPENSATION X WCSTATII- OTN- B AND EMPLOYERS'UA EUTYTNER E.L.EACH ACCIDENT f 1.000.000 OR UNIT ANYCERPMEIXEREXCLUD�"'TIVEY❑ 76WEGPH1146 OFFICERrM 1.Kin EXCLUDED? N N/A 06/22/201$ 0612212016 (Mandabry fn Niq EGL DISEASE-FA EMPIAYE f 1000.000 Ipes,dnalb-udW 1.000.000 OESCRIPTN]N OF OPERATIONS bel- E.L.fx$EASE-POUCY UMrT f i i DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(AtInh ACORD 101,AddWenM R—ke Sd*dL*,tl maa SPaa Is r"Wtod) SunEdison Inc is named as an additional insured in regards to the general liability policy. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE Sun Edison Inc, EXPIRATION DATE THEREOF.NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS,BUT FAILURE TO MAIL SUCH NOTICE SHALL IMPOSE NO 600 Clipper Drive OBLIGATION OR LIABILITY OF ANY KIND UPON THE COMPANY,ITS AGENTS,OR Belmont,CA 94002 REPRESENTATIVES. A THORIRIZEDD.REP TA 9986-2010 ACORD CORPORAV4..AI'rights reserved. ACORD 25(2010/05) The ACORD name and logo are registered marks of ACORD AC --*i KMw F7/7/2015 TE(MMIDDIYYYY) CERTIFICATE OF LIABILITY INSURANCE R001 THIS CERTIFICATEIS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT:If the certificate holder is an ADDITIONAL INSURED,the policy(les)must be endorsed. If SUBROGATIONIS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsement(s). PRODUCER CONTACT PAYCHEX INSURANCE AGENCY INC/PAC (AIC,No. (aC...): (888) 443-6112 250881 P: F: (888) 443-6112 DRESS: PO BOX 33015 INSURER(S)AFFORDING COVERAGE NAICN SAN ANTONIO TX 78265 INSURER A: Sentinel Ins Co LTD 11000 INSURED INSURERS: Hartford Casualty Insurance Co 29424 INSURER C: TWIN STATE SUN LLC INSURER D: PO BOX 1855 INSURER E: NEW LONDON NH 03257 INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. LNSR TYPE OF INSURANCE ADDL SUBR POLICYNUMBER POLICYEFF POLICYEXP LIMITS COMMERCIAL GENERAL UABILnY EACH OCCURRENCE $1, 000, 000 CLAIMS-MADE19 EMISES Ea OCCUR PREoccu'rence $1, 000, OOO A X General Liab X x 76 SBU UI1461 06/22/2015 06/22/2016 MED EXP(Any one person) $10, 000 PERSONAL&ADV INJURY $1,000, 000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE s2,000, 000 POLICY F—]JE O- LOC PRODUCTS-COMP/OP AGGs2,000, 000 OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT (Ea accident) $ ANY AUTO BODILY INJURY(Per person) ALL OWNEDSCHEDULED AUTOS AUTOS BODILY INJURY(Per accident) $ HIRED AUTOS NON-OWNED PROPERTY DAMAGE AUTOS (Per accident) $ UMBRELLA LIAB HOCCUR EACH OCCURRENCE EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED RETENTION s $ WOAXERS COMPENM TION X PEROTH- ANDEMPLOYERS'LI BILITY STATUTE JER ANY PROPRIETOR/PARTNER/EXECUTIVE YM E.L.EACH ACCIDENT $11 000,000 OFFICER/MEMBER EXCLUDED? B (Mandatory in NH) NIA 76 WEG PH1146 06/22/2015 06/22/2016 E.L.DISEASE-EA EMPLOYEE $1,000, 000 If yes,describe under DESCRI ON OF OPERATIONS below 11, 000,000 E.L.DISEASE-POLICY LIMIT DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached M more apace Is squired) Those usual to the Insured's Operations. Please see Additional Remarks Schedule Acord Form 101 attached. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. SUNEDISON RESIDENTIAL SERVICES LLC A UTHORIZED REPRESENTATIVE 600 CLIPPER DR BELMONT, CA 94002 ©1988-2014 ACORD CORPORATION.All rights reserved. ACORD 25(2014101) The ACORD name and logo are registered marks of ACORD i AGENCY CUSTOMER ID: LOC#: ADDITIONAL REMARKS SCHEDULE Page of AGENCY NAMEDINSURED PAYCHEX INSURANCE AGENCY INC/PAC POUCY NUMBER TWIN STATE SUN LLC SEE ACORD 25 PO BOX 1855 CARRIER NAICCODE NEW LONDON NH 03257 SEE ACORD 25 EFFECTIVEDATE:SEE ACORD 25 ADDITIONAL REMARKS THIS ADDITIONAL REMARKS FORM IS A SCHEDULE TO ACORD FORM FORMNUMBER: ACORD 25 FORMTITLE: CERTIFICATE OF LIABILITY INSURANCE Certificate Holder is an Additional Insured - Vendors, per the Business Liability Coverage Form SS0008, attached to this policy. Waiver of Subrogation applies in favor of the Certificate holder per the Business Liability Coverage Form SS0008 attached to this policy. Coverage is primary and non-contributory per the Business Liability Coverage Form SS0008 attached to this policy. ACORD 101 (2014/01) ©2014 ACORD CORPORATION.All rights reserved. The ACORD name and logo are registered marks of ACORD PAYCHEX INSURANCE AGENCY INC/PAC PO BOX 33015 SAN ANTONIO TX 78265 I SUNEDISON RESIDENTIAL SERVICES LLC 600 CLIPPER DR BELMONT CA 94002 ACORD 25(2014/01) I 4�— &44 a C,Ile le j C/ ZI Office of Consumer Affairs and Business Regulation 10 Park Plaza - Suite 5 170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 135714 Type: Individual PAUL F. CANALI Expiration: 5/1/2016 Tr# 251504 PAUL CANALI 28 AFONSO WAY -------- MILLVILLE, MA 01529 Update Address and return card.Mark reason for change. SCA 1 t5 20M-05/11 [] Address D Renewal ❑ Employment LF] Lost Card (?0y)1j1?0j1r1'Ce11111 0 Office of Consumer Affairs&Business Regulation License or registration valid for individul use only =,registration: OME IMPROVEMENT CONTRACTOR — Jbefore the expiration date. If found return to: 135714 Type: Office of Consumer Affairs and Business Regulation -txpiration: 5/1/2016 Individual 10 Park Plaza-Suite 5170 PAUL F.CANALI Boston,MA 02116 PAUL CANALI 28 AFONSO WAY MILLVILLE, MA 01529 �� w I-Z,— Undersecretary Not v id without sig'n—at—u—re-- Massachusetts -Department of Public Safety Board 04.Building Reguiat,cns and Standard --.___ _.o.. uunu3 ii ui�u iujx1�ix_n_ License: CS-097790 PAUL F CANALI 28 AFONSO WAY 1113,; Miltville MA 01529 :71 •" Expiration Commissioner 01/04/2017 GENERAL NOTES: N.T.S PV-P1 1.LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION. COVER SHEET 2.NO SHEET METAL OR TECH SCREWS SHALL BE USED TO GROUND DISCONNECT ENCLOSURE WITH TIN-PLATED ALUMINUM LUGS;PROPER ARRAY - 75 MODULES GROUNDING/GROUND BAR KITS SHOULD BE USED. ARRAY TILT=27" 3.ALL EXTERIOR CONDUIT,FITTINGS,AND BOXES SHALL BE WITH RAIN TIGHT AND APPROVED FOR USE IN WET LOCATIONS.(NEC 314.15A). 4.ADEQUATE SPACING ARE MAINTAINED BETWEEN ANY PLUMBING VENTS EXTENDING THROUGH THE ROOF AND THE UNDERSIDE OF THE PHOTOVOLTAIC AZIMUTH = 230',50° PANELS(6"MINIMUM RECOMMENDED OR 12'HORIZONTAL). z S.SEPARATION DISTANCE MEASUREMENT FROM BOTTOM OF PANEL TO TOP OF ROOF COVERING SHALL BE MINIMUM 4'. ROOF TYPE-COMPOSITE SHINGLE w 6.BACK-FED BREAKER MUST BE AT THE OPPOSITE END OF BUS BAR FROM THE MAIN BREAKER OR MAIN LUG SUPPLYING CURRENT FROM THE UTILITIES. 1 STORY BUILDING 7.ALL CONDUCTORS EXPOSED TO SUNLIGHT ARE LISTED AS SUNLIGHT RESISTANT. w cc 8.PLUMBING AND OR MECHANICAL VENT SHALL NOT BE COVERED,OBSTRUCTED OR RE-ROUTED AROUND SOLAR MODULES.(12'MIN. CLEARANCE 9.SMOKE ALARM AND CARBON MONOXIDE ALARM REQUIRED. 10.ALL WORK TO COMPLY WITH 2009 INTERNATIONAL BUILDING CODE;2011 ELECTRICAL CODE[2011 NEC]-ARTICLE 690,ALL MANUFACTURES LISTING AND INSTALATIO INSTRUCTIONS. °0 r� 11.A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH STATE REGULATIONS.PROPER ACCESS AND WORKING CLEARANCE WILL BE UNGROUNDED INVERTER ® N N N PROVIDED AS PER SECTION 110.26 CEC. j w w w uj POSITIVE GROUNDED INVERTER ❑ � N N N r 12.ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED,LISTED AND IDENTIFIED IN ACCORDANCE WITH UL1703 SECTION m y a y y R902.4 NEGATIVE GROUNDED INVERTER ❑ Lu F� 13.THE WORKING CLEARANCE AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN m(D W ACCORDANCE WITH NEC 110.26. rn ENPHASE MICROINVERTERS ❑ - >_N 14.ALL CONDUITS AND EQUIPMENT SHALL BE PAINTED TO MATCH THE EXISTING BACKGROUND MATERIAL COLOR OF THEIR LOCATION. 15.GROUNDING BUSHINGS ARE REQUIRED AROUND PRE-PUNCHED CONCENTRIC KNOCKOUTS ON THE DC SIDE OF THE SYSTEM.(NEC 250.97). 16.DRAWINGS ARE DIAGRAMMATIC ONLY.THE LOCATION AND ROUTING OF RACEWAYS SHALL BE DETERMINED BY THE CONTRACTOR UNLESS A OTHERWISE NOTED OR STANDARDIZED. THIS PROJECT SHALL COMPLY WITH THE 17.ALL EQUATIONS ACCOUNT FOR WORST CASE CONDITIONS. 2012 INTL BUILDING CODE(IBC) z 1& 0tO r~n 18.IF A DISCREPANCY IN QUANTITY OR SIZE OF CONDUIT,WIRE,EQUIPMENT DEVICES,OVERCURRENT PROTECTION,GROUNDING SYSTEMS,ETC.(ALLo, O 2012 INTL EXISTING BUILDING CODE(IEBC) EQUIPMENT AND MATERIALS)THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIALS AND SERVICES REQUIRED BY ,L o a INSTALLINGTHE STRICTEST CONDITIONS IN THE SPECIFICATIONS OR NOTED ON THE PLANS TO ENSURE COMPLETE COMPLIANCE WITH ALL CODES AND TO ENSURE 2012 INTL FUEL GAS CODE(IFGC) o F THE LONGEVITY AND SAFETY OF THE OPERABLE SYSTEM. 2012 UNIFORM PLUMBING CODE(UPC) S 19.ALL OUTDOOR EQUIPMENT SHALL BE MIN.NEMA 3R RATED. 2012 ENERGY CONSERVATION CODE(IECC) v} 20.METAL CONDUIT AND ENCLOSURES SHALL BE USED WHERE PV SOURCE OR OUTPUT CIRCUITS ARE RUN INSIDE A BUILDING. 2012 INTL RESIDENTAL CODE(IRC) of z 21.THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH ANY AND ALL REQUIREMENTS GIVEN BY UTILITY COMPANIES. 2012 INTL MECHANICAL CODE(IMC) wl le go 22.FOR ADDITIONAL EQUIPMENT SPECIFICATIONS,SEE PROVIDED CUT SHEETS. 2012 INTL FIRE CODE(IFC) o �N U 23.ALL LABELS AND MARKINGS SHALL BE ATTACHED ACCORDING TO REQUIREMENTS BY NEC AND THE LOCAL AHJ.THE AHJ MAY HAVE SPECIAL LABEL 2011 NATIONAL ELECTRICAL CODE(NEC) N 1'0 REQUIREMENTS BEYOND THE SCOPE OF THIS DOCUMENT.THIS MAY ENCOMPASS LANGUAGE INCLUDING,BUT NOT LIMITED TO,THAT FOUND IN NEC ORDINANCES OF THE CITY OF ARTICLES 690.5(C),690.14(C)(2),690.17,690.53,690.35(F),690.54,690.64(B)(7)AND 705.10 24.INSTALLER TO FOLLOW ALL LOCAL JURISDICTION GUIDELINES. NORTH ANDOVER U� o 0 25.THE WORKING CLEARANCE AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED z v o a SHEET INDEX WNW MAP LG ELECTRONICS-LG 305 NIC-B3& 6� a PV-P1 -Cover Sheet P6- Inverter Sheet _ c SOLAREDGE-SE9KUS-209V P2 - Plot Plan P6A- Optimizer Sheet ` 1 Z P2A-Root Plan to Scale P7 - Rails/Grounding LISTED BY UNDERWRITER'S W _ i a P3-Three Line P7A- Fire Rating Rails LABORATORIES FOR ELECTRICAL Z P4 - Rafter Side View P8 -Attachments AND FIRE SAFETYqj P5- Module Sheet P9 -Warning Labels (( $A FIRE RATING) ? _ P5A-Fire Rating Sheet w Z Z 1)NOTE:NO DISCHARGE OF ANY POLLUTANTS S z TO ANY STORM DRAIN SYSTEM. U O w 3 2)UL 1703 FOR MODULES&UL 1741 FOR INVERTERS m a C�EL X �� �. syn.7 PER CITY SOLARREQUIRMENTS. kdo c,,, 2011 NEC,CITY/COUNTY FD-MARI KINGS, v y, Solar Permit Services,Inc. 94"72.e2m a LABELS,AND WARNING SIGNS REQUIRED DISCLAIMER:H Errors,Disse _._-- ------ -- ----_-_-.- anty Discrepancies or Omissions appear in these drawings,speaficatio or other contract documents;The Owner or General Contractor shall the Dec' _ _ - ratrfy Designer,in writing,of such error or omission.In the event that the Owner or General Contractor falls to give such notice,before construction andfor fabrication of the work,the Owner or General Contractor will be held resporreible t0 the mstdt of any errors,discrepancies or omission and the cost of nectitying them. SCh' PV-P2 NATE 91WBfMIDi& 1. 1118` .-W POINT LOAD CALCULATION PER ARRAY W3RIMECLFARAIIIELOR LAUSMPA RTANDma=DffmAEMPIWmByozm ENRGnmWOwsMBNEUAG FRDMoVOMMYN PLOT PLAN WMSS UPANMAIOACDOMINNL EMBED87 N ITEM NOR WEIGHT TOTAL WDAMBY06TM.EL PM8Mx6MOtRBPOM FCNSRN4QIM051WC IDIFADmaWEamTHm OMMRNWLTAEALL IEO333/R1'PW="MBWdEI1FWAFM EAMINGWMAEAaAT1A101ROFUMMAILn*W M WNMfAOOWIIINTPMDWAWMIATD PE fib.) W ROOF RTRNX"FOWTLOCATUM BIRNEEWR OSTHICTUlE WIEGIMISTIE RBDRB)Bra6101EAAADDRAua ANOMMORMm [RNfATIMICTHMDO WWIMWOMWOR y, 4 MODULES 75 38 2850I PESraIEERmaTxErsrAua aTwuuxArACMdArtxBsrsleeRsmuTcswsrERlsNn®roweaAwuoonuMarAmxomEs RAILS 507 .5 251 FOAARo1AL ADXW&V IAkY BE PEOUREOMETOEIBSIDORERIAWMIt. � RACKING PARTS 140 .5 70 21EMroAIW1MI0MTEARIORBIfFARB0AW A6fNUi18NMMINLSNDIRO®IAlSOUx611416TAUTpN Z \Y` ' TILT LEGS WA 3.5 WA 2MI IMMOWLEECTRICALC00EPMIR -MTX3EED,AU. ABFACaRES MPRDMMANDCMWMMTMMUA(i[OTaCOMMM(MWYVM F W SRNG AILD IWLATMALPBmUCI IONS. s/ OPTIMIZERS U 75 1.7 128 RD1E SFAKUG"AIMY91 MMA1 MMISUFRUMASMAOMKABIF1EASRUi9ECRfltlLOOMMAO J o,t 3298 RDOFACMPOKM BELOGATEIEAIWASTINrDONOTiEOMPE GUREMOFIMLVMAEABMMA ERSAESILLPCgEtEDEIW®1A1GY390AFEtWFE EIDRR o O NOF MOUNTS 3299/140 =23.56 LBS PER MOUNT KA03,BROFGMMLAM �OVER019/0M=ASWWDMSCRD0Ml4, ��F��'���� �w fA `-- LBSIPER SO FT 3298/1324= Z49LBSPERSOFT ANDU)rAI)ATSTRMPOK90FWLCMOMSTNC"NLOrArOM WIBE TIEAOLESBPOE/TDOFSNOTOOIRUCTLNIH0Y9UEADOBSRNCIlON3 SUOIASTIEEUB4,WRESORM& a 250'-0"PA_ — _ — — — — I N NON I CIA W 1 so'EXTERIOR 314"ENT DC CONDUIT I , N N N MIN. 3.5"ABOVEROOF I (n U)N LABELED OC EVERY 70'(TVP) I yW222 (N)(3)INVERTERS-SE 9KUS-208V I J W W W DRIVEWAY WARNING LABELS, I F-N ARRAY#2 OUTSIDE I I 5Qj N 4 MODULES 2— 3'-0'FIRE SET BACK ROOF TILT 0 27° (N)1R0 AMP 208V SUB PANEL ROOF AZIMUTH @ 50° OUTSIDE I RAil38ATTACHMENT(TVP) I III I J I I .I BOX ON ROOF I SEALED TIGHT I III VENT•(TYP) I I NON-FUSED-NEMATYPE3MIN O I I W 0 In p W ————__—— • • ————— 11 FLAT ROOF I Zi QQ O g I rc WI 1_ (+f o i� �+ U PARKING LOTS I SI � Z I rTYP) O I �I 0 Y� �a I I > I w n O v a 2a I o moo V > a '"'I CL 0 o I ARRAY#1 (N)128 AMP AC DISCONNECT 71 MODULES OUTSIDE I EV OC ROOF TILT Q 27° (N)PERFORMANCE METER U C) O ROOF AZIMUTH®230° OUTSIDE tf0'INTERgRIEXTERK)R 1"EMT AC CONDUR 3T-0' I J Z U ZO J s (E)200AMP MAIN ELECTRICAL 2HAtEIC.1P I I }Q= F 3 SERVICE O / p ,3TALL I Cr$ ZO g — — — — — — — — _ — METER 872988073 W — — — —_.. ,_�— _ I ZZ V IIS DRIVEWAY 290'-0"P2 I y a I FIROW �7ry� w —_—170 PLEASANT ST __— ------------------------------ ------- ----------------- Z Z j PARIONCSMLL STRFOIG 7F0WI dAs aAW ® CB611INMITWFI rlWC91R► }r o aBEiMGVIHQOIRW7.9 tli¢RMP IATIE 1nB®Irro ® e mERrWaacIIKJ Y 8 Z a xawxD20Efx0IWEC/PAAAElOs1l� ADY/SRro ffiRFNE9tl6RIURACC�ME (Q m O W IIDRILL FABMe9nNI96WU IA'F _ C7 F +.eisrls•DroIErWDE B®axAnnEsmR xy,®� SCALE: m (L X m y 2531xQSNA1Ktl'EolEBiOGRMADWIIXYMEIiMl1E ® ® IWxmMO RDMnMRa1 9 2' 5' 10' 20' 30' S0' 3Ro,DETRocarsarPArt :LanRRRiq l 8(1W01&MILEg311 VPN0GSrALL SMESA60liBt KYBCNFNxlp9fpl B�FORTV� EDGE TO EDGE 1S E TO EDGE • R�Vt DISCLAIMER:If any Errors,Discrepancies or Omissions appear in these drawings,specifications or other contract documents;The Owner or General Contractor slrefi no*the Designer,in writing,of such error or omission.In the event that the Owner or General Contractor fails to give such notice,before am*ucbon and/or fabrication of the work,the Owner or General Contractor will be held responsible to the resuft of any errors,discrepancies or omissions and the cost of rectifying them. SCALE PV-P2A 3/32"-V-O" ROOF PLAN I Z L ) 1b0'EXTERIOR 0H'EMT OC CONDUIT l�f•�{ H F W 4 MIN.IS-ABOVE ROOF fn d v LABELED DC EVERT fO'(TVP) gO r UUU Oh(3)INVERTER SSE"iN �0 a ARRAY#2 WARNING LABELS, 4 MODULES OUTSIDE W Y Y ROOF TILT 0 27° L] r r g ROOF AZIMUTH 50° +®2M O.C.RAFTERS (N)I60 AMP 208V SUB PANEL 00 ® (TYP) OUTSIDE _ N N N Lu Lit Lit b BOX SEROOF/SEALED TIGHT -III J , N N N -RAILS dATTACNMENT ) NON-FUSED-NEMA TVPE3 MIN. II ® u�11 (C'0' (N N III J W W W I III (nU)U3 ��� I III �M VENT(TYP) +: I III 1 � -------------------®— --------1U) I � z U) ®® ® 1 11 FLAT ROOF O u) O LU — ------F I LLa a :TT J p� + 10Yg a Fl 00 5171 17111 474, -1 N d� O N y 1-11' Al1 (N)12b AMP AC DISCONNECT" JUJ LZ Or 71 MODULES OUTSIDE - J ? o a ROOF TILT(8127° - } 3 ROOF AZIMUTH 0230- (��RRFF PERFORMANCE METER 190'INTERIORIEXTE JOR I-EMT AC CONDUIT �� 0 X DE W L U J PERaiv�mu l• (E)20CAMP MAIN ELECTRICAL rZjJ It gEOVIREMEMs ? SERVICE PANEL co N }p asY ROOT ATTAp�ENTTIP. OUTSIDE efNm4o MMTASHW METER#72888013 Z Z WT- rz l �LGEIEC7ROPi1CS-LG305N1C-e3 S�(�Z L 39.37"x 64.ST U O FRONT 4 SCALE O' YS' 10' 15' 20' to�" X RMIRARFMIEL DETAL LAYOUT 170 PLEASANT ST 3/32"=T-D" 1, rmTTascMLF DISCLAIMER:If any Errors,Discrepancies or Omissions appear in these drawings,specifications or other contract documents;The Owner or General Confrador shall nobly the Desijrw,in writing,of such error or omission.In the event that the Owner _ or General Contractor falls to give such notice,before cons6udion ardor fabrication of the work,the Owner or General Contractor will be held respormI to the result of any errors,discrepancies or omissions and the cost of rectifying them. ELECTRICAL NOTES: N.T.S PV-P3 E7.ALL EQUIPMENT IS LISTED FOR USE. E11.THE POINT OF CONNECTION COMPLIES WITH APPLICABLE CECINEC. THREE LINE ELECTRICAL E2.MAXIMUM VOLTAGE DOES NOT EXCEED 60OVDC. E12.BACKFED SOLAR BREAKER(S)SHALL BE INSTALLED AT THE OPPOSITE END OF THE CIRCUIT OR FURTHEST AWAY FROM THE MAIN BREAKER. E3.ANY EQUIPMENT OR ELECTRICAL MATERIALS USED FOR THIS INSTALLATION SHALL BE NEW AND LISTED El 3.ALL EQUIPMENT SHALL BE GROUNDED,INCLUDING BONDING JUMPERS WHERE NECESSARY ACROSS RAIL SPLICE PLATES TO BOND INDIVIDUAL BY A RECOGNIZED ELECTRICAL TESTING LABORATORY. PIECES OF RAIL THAT E4.CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES OR JUNCTION ARE CONNECTED AS AN EXPANSION SPLICE. BOXES(COMBINER BOXES PER APPROPRIATE JURISDICTIONAL REQUIREMENTS. E14.ALL VIRE,VOLTAGES,AMPERAGES AND EQUIPMENT IS SIZED ACCORDING TO TEMPERATURE DERATING AND LOCATION. E5.ALL PV ARRAYS SHALL BE EQUIPPED WITH DC GROUND FAULT PROTECTION. E15.INVERTER(S)SHALL CONTAIN A GROUND FAULT DETECTION AND INTERRUPTION DEVICE. Z F6.ANY AC COMPONENT SHALL MEET OR EXCEED THE AVAILABLE FAULT CURRENT CALCULATED AT THAT E16.ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS. $ 666 COMPONENT. E17.ONLY COPPER(CU)CONDUCTORS SWILL BE USED.CONDUCTORS SHALL BE STRANDED OR SOLID WITH PROPERLY RATED CONNECTORS. U a U E7.ALL MODULES AND ANY RELATED ROOF MOUNTED METALLIC EQUIPMENT SHALL BE PROPERLY E78.DISCONNECT SHALL BE WIRED SO NO BLADES ARE ENERGIZED. GROUNDED. E19.ALL MODULES AND RACKING SHALL BE GROUNDED USING 2703 UL LISTED RAIL INTEGRATED GROUNDING SYSTEM,OR VITHTIN PLATED DIRECT O O Q E8.DC EQUIPMENT SHALL BE 60OVDC RATED MINIMUM(SOLAR EDGE INVERTERS 50OVDC RATED MINIMUM). BURIAL RATED LAY IN LUGS USING STAINLESS STEEL HARDWARE,STAR WASHERS,AND THREAD FORMING BOLTS OR WEEBS. yJ W C 3 E9.MARKINGS SHALL BE PROVIDED TO INDICATE THAT ALL CONTACTS OF THE DISCONNECT EQUIPMENT Y MIGHT BE ENERGIZED. Y Y Y El 0.INVERTER(S)SHALL CONTAIN A GROUND FAULT DETECTION AND INTERRUPTION DEVICE. 1SI18NGOFt3PAN88{ 18TICiD OF 13f'A7FIS{ 181RNCOF 73 PAIS{ r iSIPoNGOFURANBS iSIRNGOF I2PMBS 1891PIG0 UPM189 N N N CALCUTATgNB FORCUPo✓E7ITCNN(YIXiWlIDUC10R3: CALQAATIDt13 FORClRIi87fCAF81YYKiC011711CfOR4 4PIANFI�-� dPARNIII AC REQI1fEDC01IDlICr0RA1PAQIY OCREOUREDCONEUCTMAWApIY SA11.79t•,S=I.:A RIECIBOtIBN1@: ( I I N m(n Avro1I.XA H1AA1PAaN: tai•1�•1�=id7{A PJZO-POWEROPIY,�Fn (�(�I)(1):35AA AMGt1a0B1ATB)AAPACIIY III 36.40A>t{01A,TNEREWREACWIRES�IBVNID. (40)(&53)(0.8)=1{58A INIOER EACH 1AOOtAE I I I N -FROM I7VER1BI8TOSUBPANEL 1BSBA>1S711 THERIFOtEOCWRESIZE 19VALID. I a ACREQUTION9RMURRBOGV8MXICOHOIIORR6: ��� '�'� J-eoxoNRooFSEALmnGHr z : z �M 78A11.102'113>18AIA'3.5LI2A OONDUM MON.FUSED-NEMATYPE3MIN OUTSIDE OUTSIDE OUTSIDE AWGIBDBIATEDAWACTfY: (IYP.) ItRMIND® UA3AARD® ui-w ® (75)N9t1111=5625A fi{25A>SL12A,WEREI�EAC WIRES�BVALIl1. (N)tlTiU7V PERFORMANCE METER ADJACENT O% Q1VfnTER>lO X wvERTL�ma� X INVFFfER ret � FROMSUBPAIIELTDAIUI PANEL Tor O MNN SERVICE PANELIP TO 7.F CENTER TO CENTEROFMETERS846'TO7SABOVE ffRLL6AY ffNLibPON .'DIF f£Pf1D47IY Z I � LLO�EUTI�LITYY COMPANY APMETER PPPROV L 7 W1L 6NC.Y193 7 MVL ERIC BIR 7 WC 6FL M9l ad O DO W In TO UTILITY GRID 1.�.�.i I I 1 m 2 c LU 208V OD,igNDRiDMMPII6 A IA to LL NOT CENOVISMWE TER FEDPATaEL (MI2SA208VAC I nowt Ie� I smwc O THREE PHASE DISCONNECT MAIN NON-FUSIBLE 3POLE, �¢ _ * _ }� ELECTRICAL PANEL NE�3R 6.LE 36 NEO690.17 Q7 OU BI-DIRECTIONAL (E)200AMP 208V ftl)7 UTILITY METER 2 (E)200AMP MCB 7d. Q METER#7298801 uNE SIDETAP 0II8oENDOTONSTIEAd L L L UI O Y a- (N)150A 2OSV PV W N LOAOCENTER ONLY 3-2M 3POlE BREAKERSS EXTERIOR 3W j( _ O u r I (CO DVCTORS IMT42 1 (I)8 C T11100-2 GROUND Lj . 04 L--- I 9DC d DRY I I U C Or O i I �z U o ---- --- ----� / I I >-_ 3 p_ MOUNTS AND EQUIPMENTI AC0'IA NTE OWEXTERIOR I-EMT I r--------------------- Z W U ------------------------------------- t ENCLOSURES GROUNDED (4)*:C THVA12 CONIXICTORS ---------------------------- ED � a TO MAIN PANEL GROUND (ITI CUTIMRL2GROUND (E)LIFER GND 901C WET&DRY Lq w¢ (1){6 CU AWG BARE GROUND WIRE i� SONDINGMODULEANDRAIL 000 W NEC 250(TYP.) Z Z MI j Z a3{ O N4EC3OG6C7(TY� z Z 3 IW EXTERIOR 3M•EMT DC CONDUR R W w O(4AH0 CU TIWUN-2 CONDUCTORS W Z �¢ CEC690.8(Aj(1),(B$1)eacft LSC=10.1.1.25.1.25=15.78A (1)e CUTFIWN-2GROUND `^� w� U SUB PANEL PV-CB SIZE=20A PER INVERTER 8 m Y= PTC RATING IS 276.9 W PANELS RATINGS: INVERTER DC MAX INPUT CURRENT=26.5 A IVC WETS DRY(TYP.) V ¢ Nmpl is 75.276.9'0.965!1000=20.04 KW-AC(CEC) Isc= 10.1 ADC VOC=40.1.13 =45.20 v/OC INVERTER AC MAX OUTPUT CURRENT IS: m It vJ 2 X 25 A/1.732'1.25=18.00 A PER INVERTER 75'276.9/1000=20.77 KW-OC(PTC) IMP= 9.52 ADC Input voltage 365173=26.07 Vdc modules per string C 9 EXTERIOR 3'4•EMT DC CONDUIT Input voltage 365/12=30.41 A modules per string (4)10 CU TNWN-2 GROUND �Y.. Total 7625W/365E =2089A (9pC 8 CU WET�2(TYP.) D Y INVERTERS DC MAX INPUT VOLTAGE=500 V/DC DISCLAIMER If any Em ors,Discrepancies or Omissions appear in these drawings,specifications or other contract documents:The Owner or General Contractor shall notify the Desgner, --- - --_: in writiu�,of sudor error or omisstaL In the event that the Owner or General Contractor fails to give such notice,before construction ardor fabrication of the work,the Owner or General Contractor will be held responsible to the result of arty errors,discrepancies or omissions and the cost of rectifying them. N.T.S I PV-P4 SOLAR MODULE RAFTER SIDE VIEW UNIRACSOIARMGUNT END CLAMP II �� 11 Z STANDARD SOLAR MOUNT BEAM f U W Y Y Y L-FOOT r a 318'-16'x314' {lqJ m n o HEX HEAD BOLT aQ N N N 3F-16, EXISTING 17 COX PLYWOOD (v=J1i FLANGE NUT %n.WITH UKOBUYMENT UJ' N N N OVER 1X6 SKIP SHEATHING m co w 222 Y4•EPDM SS FLAT WASHER QUICK MOUNT PV = 0�N _ aiu}iu}i �M COMP.SHINGL VxY4'SS HEXBOLT 6 Z N OLL 0 NOTE: SPAN OF STRUCTURAL ATTACHMENTS---0 2 2~ 511Wx3-12SSLag Bolt@ftc.Maxwb2-1(IPmwkdman for W 5M6'x4.12SSLag Bolt @VocMaxwM3.12'P&iabdm U cn 5 Ix Over RS G.and roof rafter 89 shown � 0�rn S U PER MANUFACTURERSSPECfFICAnoNs �I O Y It 20 RAFTER @ 24'o.¢ o000 U ppU 3' Na�20 S PARALLEL TO THE ROOF 6-5 /4'0 ABOVE ROOF SURFACE N o: 5 f �Z U z fi 5" _ 3 g W � W� � a 2x4 RAFTER @ 24•o,.--/ ENGINEERED TRUSSES ujN w 1.5' I C7 mp `� a m�U� Xm DISCLAIMER N any Enw,Discrepancies or Omissions appear in these drawings,speff ations or other contract documents;The Owner or General Contrada shall the r,m i —— — nobly Designer,� writing,of such error or omissiaL In the event that the Owner or General Contractor falls to give such notice,before construction ardor fabrication of the work,the Owner or General Contractor wig be held responsible to the result of any errors,discrepancies or omissions and the cost of mc<ifying them. -------- -------��'�k' N.T.S PV-P5 MODULE SHEET (9 Le Mono. - NeON Em= I-ife-s Good I Mechanical Properties Electrical Properties(STC Cols 6.10 m5 W J d V '71,11 ro LG Mlm vddryr(Vlnpp) -321 ��/r�� Ceatype _bbnttysta"an_ 4_ MPPr,r at QTw) 952 F � Celt d.- 1565a1565mm/6w6nv Open ntvavoltvle(lloc) _ ---40.0_ — - Y Y Y Y •nfbnbar 3 Awtsrcvt terlmt(Isr) 101 N f)--_.It.IN 1640,1000,35mm Mod,.effkiwc(%) 106 Ono n 607,3937,133. gxratm9tnlgerature(K) -a0-.9D N O O Slaticsmw bad TNA/113 psf Madly telnvoitapM 1000(IEC),00(M) N N N Stxk wrill lo•d 210011./50oa Madavee encs llrvm,atrg 20 , W W W KFight 168 t 051p/36963111, Ibver tdwance(7U 0-•3 N N N 1 •.', Cw,nectortrye MCa<wa+xtw P67 •s1c<sv+.eva mew.>a n,ewlwow.,i.m•n.,e.oc.7scwts ' +X lu«bm b.e IP 67 rn0,36ypn•dfodes •A""�a•"-Pei"a""'M��nM��`a'-E'ta•"f0101��O0A � W W W i® tel•7tb ofcahbs 2.1000mm/2.39.37n Gras rwgh v.rm.••.m tempered yw Electrical Properties(NOCT") _ > name iwnzdm.Iwvm .WSW Maexnlm w+n.+(Nwp) - - 223 n l0 MonoX'- N ON ea(areiHi..M Certifications and Warranty MPPvdu9e(Nrypj 299 eCe fic.m,s(lopra _) IEC 61715.tc 61730.11-2,1.11703 M1R rurtmt(lmap) __ 759 t509001,1Ec6i7ol,cC 62716 0Pe•1—"o-P W.) 770 la Redw:t>•a+nnry to yert SI—C.—llr<) a. 7 Eff Ntl„Nt ttyaP ) tawarwana,ry• } (r,®um i.frovar.7) r2% j N� rKNaW a•ltr re,.tonraw,.ayr."mna•n,a,.,, •totter...tt.. rrtnw+b.r.oroow.+,7.ww>..y..1..1nS..cw•n l.w m 0 W oLL a mmfin Temperature Coefficients Dimensions ) 00 •�•r� NOCr 45x VC — _ Of Introducing Mora X"'VeON rtadtde sores,wMcn saes 1 NOC -aa 1 VC _ to eC hghly eFfinent n-type matenas,an elaborate process @♦ l .Ilrorecea<1 1 P - .0 29 Vc •' urp�O t}p 50 ���� corttroladoptmg a semiconductor processing solution DVE U� USC♦ oW Vc �a K j•a r`11 r7 Z UZ fill andadoubk-sided strlxture Our RBD concentrates L_ .� +1 ) r O Q Q —d-.1.pmg a product that n not oMy efficmnt,but --.••� ' Characteristic CurveS '�"-" n U St,wes to N�CIEaSe piactlCal Value rW CUSIof0 M �: M1I Oa Nd�co0 N-Type Material Near Zero LID(tent kAd a pd.n s- r nn) ` 111P Morro X"'NeONuses n-type ce"A bpastulg 116 The n-type ce"s used n Mdw X'"NeON hwe O o hgher mob',y of decide charge,resdung n chrost no borm,whch m:y cause the venal t lsgher generston effiuelry effk,,wy W drop,IevLrc3 to less LID _ '^— • Z Q z L = a Z3 I V ko°aeiy Nano Level Control Double-Sided Cel(Structure s !y - 1 I +' :2 Z ci •ver,«a♦ ��. I:< I r:,• W C0 wa Mono X"NeON uses sive Nano-k Yt process The rear of the cell used m Mono X^'NeON rs #In � � cornrolpredpemlant msetrvcondu Idesn,efloed f-their t the the 4gh[ pracessrtig(rocesA wtxch en•,ures less electnc beans lefkcted Fran:the rear of the module T, loss horn mlernal defect, reabsorbed[.gmeratea great em .1' adtht—al P_ z a8•q O O t► oro r • a a » „ .Tswnitl 1lae,oCaM1alaw alcored Z �«.r ti,.• �m�S S1 Q LG wt.rl,q�sd.s1.,�..*�,. Pan,w•e•r...,...Is,..,.,r..,y.•..•..a 1.,., Q Q m v'IIIJJJ a X m y nharrt tG Ft«nwwa is t00p5yMnM�'ry4.mlUnyWO'7af7 NWaln4w•vLc•n.•_4p�n,�dtl,sr lspaRrnwlvs Yr• teouw.c..,nnmw,m.Iwwrewlm..,.eedm�m.a�v�aq.erywah:a.r«..e,b„ws;mchm..m�'•r*r�..a.,wn.«.m.wRerw.,cnpoyen..:r,d+a.iws; u.seom �K4��� osn.so-[u.r-Fa,-3xoo? wxnx4r.rprow a e Yf- n tee6,ie6.•«Ir•.Id,.P�.,.•na»<ma,e�tm,d.,.,•ly�amm,•r a�n»r,.,a<u1..ve.,,,R�rey„k.•.ad.6»t wox�,a.�n m,heal.hnn zotn,wdl.�p•radn37 xw: run UPrdeo7ou to k rep wl.yK.ar....d Q � a 3 ,�....._..>..,._.>,,,,..w...,e.1.,.n..._•�..._..+... ...._,...v,s_.....�.._,«•..a.... asrnrou i DISCLAIMER-If any Errors,Dwepandes or Omissions appear in these drawings•spedfications or other antra documents;The Owner or General Contractor shall notify the Designer,in wilting,of such error or omission.In l he event that the Owner or General Contractor falls to give such notice,before construction andlar fabricalion of the work,the Owner or General Contrador will be held respomble to the result of any errors,discrepancies or omissions and the cost of rectifying them. WT.S I PV-PSA ® Intertek Testing Services Shanghai Inlertek Testing Services Shanghai FIRE RATING SHEET Building No.88,1198 glnxhou Road(North), Building No.86.1198 Qmzhou Road(North), Caohejing Development Zone. Caoheong Development Zone, Shanghai 200233,China Shanghai 200233,Chlna Tel:86 216127 8200 Fax:86 216495 6283 Te1:86216127Fax:86216495 6283 ' Annex to Test Verification of Conformity Test Verification of Conformity z� r a v This is an Annex to Test Verification of Conformity with Verification/Report Number(s): 000 141101643SHA-001-V7 if 141101643SHA-001,140815004SHJ-BP-1,140815004SHJ$P-2. W 00< On the basis of the tests undertaken,the sample(s)of the below product have been found The issuing office is Intertek Testing Services Shanghai(Address:Building No.86,1198 Oinzhou Road 3 to comply with the requirements of the referenced specifications at the time the tests (North),Caoheiinq Development Zone,Shanghai 200233,China) Y Y Y were carried out. Go g 7 N N N Ratings and principal characteristics Applicant Name&Address LG Electronics Inc. N N N Max.310W,Min.25OW rn 168,Suehul-daero,Solar Business Division(Solar Module Fire Performance((for modules with below specified construction only)):Type 2 W w W Factory),Gumi-si,Gyeongsangbuk-do 730.903,Republic superstrate 2 8-4.36mm thick, of Korea Encapsulanl(Super/Cell).0.25-0.55mm thick, — Y Y Y Manufacturing site Name&Address Pp Encepsulant(CeIIISub).0.25-0.45mm thick, on N rn 9 Same as applicant Substrate,0 285mm-0.3mm thick, m A l9 Product(s)Tested PV Module Ratings and principal characteristics See Annex 1 Model(s) s See Annex 1 LGxxxS1C-A3('xxz is the number from 250 to 280,in step of 5), Of ModelOf LGxxxS1K-A3('xxx'is the number from 250 to 275,m step of 5), Z LGxxxSt W-A3('xxx'is the number from 250 to 280,in step of 5), I eb Dr� Brand name LGxxxS1C-B3('xxx'is the number from 250 to 280,In step of 5). m 0 'n ® LG Electronics LGxxxS1 K-83(kxx'is the number from 250 to 275,In step of 5), 2o W LGxxxSi W-03('xxx'is the number from 250 to 280,in step of 5), U.O <F Relevant UL 1703 Issue:2002/03/15 Ed:3 Rev:2014/05/20 UL LGxxxN1C-A3('xxx'is the number from 270 to 305.in step of 5), 0 LGxxxN'I K-A3('xxx'is the number from 270 to 300,In step of 5), O w Standard(s)/Specification(s) Standard for Safety Flat-Plate Photovoltaic Modules and LGxxxN1 W-A3('xxx'is the number from 270 to 305.In step of 5). Panels LGxxxNiC-B3('xxx'is the number from 270 to 310,in step of 5), U Clause 31 Fire tests LGxxxN1K-83('xxx'a the number from 270 to 300,in step of 5). ZZ ZZ LGxxxNI W-83('xxx'is the number from 270 to 310,in step of 5). O Y Q Q Verification Issuing Office Name& Intertek Testing Services Shanghai a v Address Building No.86,1198 Oinzhou Road(North),Shanghai a y U 200233,China n C4> 00 wd�z0 Verification Number 141101643SHA-001-V1 Report Number(s) 141101643SHA-001,140815004SHJ-BP-1, N cc 140815004SHJ-BP-2Z u i r z Z _ NOTE:This verification is part of the full test report(s)and should be read in conjunction with it WW U ' This Vm;f—tion is for the axdmW use of Int.dek's Client and it Idea NOTE:This annex Is part of the Test Verification of Conformity and should be read In conjunction with it. z Ci pagr Wnsuam to the agreement behwen Intertek and its Cto the IClknt In 03 W reeparsibifity,end he agn aro milked to Ilse and co r am a of the re—d nt.he—assumes no a tem, a any party.thea the to the Cltont In a accordance with the�raement,for any Ipss.axlanse m damage oaaaianed by the use or era Vedf tion.Only the Client is emhmized to copy or This Veirdy man it ku the externs use o Intmlek a Giem ma is provided k assumes to the agreement between Intertek and iia Client Intedek's respmslhme d-wribule this Verification.Any use of me mistral,name or one of Its marks for the sale m advertisement of the tested maledal,product m senke must first and I�bdlry me lender a ins temp and wnmaorts of IM agreement Intertek assumes no f bkry to any party,dhM than to the C6M!In exorQance w,lh lire S alppa'/�)IC-4 be approved in writing by Intertek.The Ob—atkms and test reaulls refinenoed from this Verification aro relevant only to the sample mstel This agree nmr 1,fm any loss,expense or damage acts ad by me sae of thb Vonacellon.only the Chem Is euthmlmd to copy m distribute Nn Va,xkMion f7 N Z Z Ven(ieaaen by uaNf does not imply Nal the mahmei.produce,or service Iib m Aye ever beer,urMm an mm ek cerlificadon Any uta of the intertek name m one of its marks for the sale m advonu¢meal el the tested malarial,product m ae must Aral be nppaamd m writing by O 4l u1 man' Inlertek.The observalbns are lest nesuls mtemnca0 from des Vemra bmm erNevara only to the sample issued.Thus VerMahea by Mee does not Imply =W ty j //,,'' her Ire ma anal,pmQut,or sery ce is or fns ever been under an InlMek cemfree[bn program. z z aj z (�3 e - I Signature , m?O w 3 Signature `z Name:William Cheng m a 13L: X N Position:PV Name:William Cheng Date:06 January 2015 Position:PV Date:06 January 2015 Is DISCLAIMER:9 any Enors,Discrepancies or Omissions appear in these dravAngs,specifications or other contract documents;The Owner or General Contractor strep ' notify the Desgier,in waling,of such erre or omission.N Bre event that the Owner or General Contractor falls to give such notice,before construction andfor fabrication of the work,the Owner or General Contractor will be held responsible to the result of any errors,discrepancies or omissions and Etre cost of rectifying them. Three Phase Inverters for the 208V Grid for North America N.T.S PV-P6 so I a r= SESKUS/SE14AKUS1° — INVERTER SHEET solar=ee 0 OUTPUT SE99us SEMAKUS - Rated AC Power Output9006 II 144001. 1.VA Zj Maxims m AC Power Output i 9000 14400 VA AC Output Line Connectionsini4-wire WYE(Ll-L2-l3-N)plus PE or 3 wire Delta + d U AC output Voltage Mmum-Nominal- U U SolarEdge Three Phase Inverters ® Maximumui(L-N) ; 10i-120132.5 Vac Q AC Output Voltage Minimum-Nominal- i 183-208-229 Vac for the 208V Grid for North America Maximam"''L-�' �Y AC Frequency Min-Nom-MaxP" I _ 59.3-6I . I Hx r r1 t/ (� (� qA /1 (� Max.Continuous Output Current(per Phase)( 25 40 A - - - SE9KUS SE14AUS GFOIThreshuld 1 A N N N x Utility Monitoring,151anding Protection, Ill 111 111 Yes Country Configurable Set Points NNN INPUT U N U .. - Maximum DC Power IModule STC) 12150 19400 W. 2 Tmnslarmer-less,Ungrounded I Yes ., - W W 1� ( i 4 Maximum Input Voltage DC to Gnd �. _ 250 _- - ,._ 300 Vdc Y T Maximum Input Voltage DC to DGr 500 606 vdc y U!n 'f �-_• Nominal Input Voltage OC to Grid 200 ,. Vdc u1 @4- Reverse-Polarity ' Nominal input Voltage DC+to DC- 4D0 Vdc Maximum Input Current 26.5 i 38 Adc ' Max.Input Short Circuit Current 45 Adc Protection yes GroundFaultIsolation Detection IMO Sensitivity l'- s x' CEC Weighted Effciency 96.5 97 °.I. ab 0 Ir Night-time Power Consumption c 3 I <4 W W 0 p W I _ ADDITIONAL FEATURES LL I Supported Communication Interlaces RS485,Ethernet,LgBee(optional) O f Rapid Shutdown-NEC 2014 690.12 With installation of rapid shutdown kital 0 W _ .- _ .. With.installation__ _ ..- F STANDARD COMPLIANCE Safety t Ui1741 ULI6IEEE 541998,CSA 22.2 U} .. .. ... .. { Grid Connection Standards r IEEE7547 I O Of U Emissions FCC PartiS class 0 r r y� TQ Q __�+-•:T�'i _INSTALLATION SPECIFICATIONS _ .crCl` . _--_ _ -- t AC output conduit size/AWG mngc i_ _ 3/4 1 imum 112-6 AWG O 00 y U DC input conduit Site AWG range - .. 3/4 mmmum/32.6 AWG, ., a Nor O ... .... . Number of OC mputs 2 Pairs I 3 Palm(with fuses on plus&m nus)t"'.. Dimensions iHxWxD) 21 x 125 x 10.5/540 x 315 x 260 tin/mm Dimensions with Safety Switch(HxwxD) 30.5 x 12.5 x 10.S/775 x 315 x 260 I in/mm fV F !i Weight 73.2/33.2 .99.5/45 0 0 0 Weight with Safety Switch 797/36.2 106/48 Z U Q Cooling j Fans(user replaceable) - }=Z' 3 Noise .. .... .. <50 ., <55 'dBA �L Operating"temperature Range .. _ 1 -.. .. _. _. 40 to+140/-40 to+60 ._, ,i_F/C- 0 Protection Rating NEMA 3R z C.f The best choice for SolarEdge enabled systems �Inµxa wrae•n«EpSJWxnYb - --=waPtanasavu:mwomma w� w Lo o „a moaown sn,/x mm«,sa>ih, {= Integrated arc fault protection for NEC 2011 650.11 a�maw=.m.m,xrwry�ra«wa wi..ocasa..nax. � ti w Q � s N3 - Rapid shutdown for NEC 2014 690.12 � Outdoor and indoor installation _ _ :3 •� Built-In module-level monitoring Internet connection through Ethernet or Wireless - y y SLe15f�C 2 Small,lightweight and easy to install on provided bracket •" $Z to Q Fixed voltage inverter,DC/AC conversion only �;. - �' - no Z 0 to 3 Q - Integrated Safety Switch .-t �a��. -�� - m--tV a x ro y USA-GERMANY-ITALY FRANCE-JAPAN CHINA-AUSTRAIIA THENETHERLANDS,-UK ISRAEL www.solaredge.SS i DISCLAIMER:If any Errors,Discrepancies or Omissions appear in these drawings,specifications or other contract documents;The Owner or General Contractor shall notif}r the Designer,in writing,of such error or omission.In the event that the Owner or General Contractor falls to give such notice,before construction aldfor fabrication of the work,the Owner or General Contractor will be held responsible to the result of any errors,dWepandes or omissions and the cost of rec*ng them. ,'c,�;�., . N.T.S PV-p solar=39SolarEdge Power Optimizer Module Add-On for North America OPTIMIZER SHEET ® P300/ P320/ P400/ P405 solar=@@ _ T P300 P320 P400 P405 Z (for 60-.11modulo) (for high-power Irnr 71t496se11 (brthln mm r'�Q{ U U U INPUT = Imo odWe morluk) -" U)�v gbcel 4a1 a) s) S0�8tEdge Power Optimizer Rated InputDCPuweroi 300 320 400 — 405 W, U U U F. �w oo¢ Absolute Maximum input Voltage 4S 80 125 Vdc y (Voc at lowest temperature) - ��3 Module Add-On For North America MPPTOm sting Circuit , 8-.48 8 t30. 115-105 j Vdc N Y`1 *-� Maximum Short Circuit Current(Ise) 10 11 .. 10 Adc Maximum DC mpW Current , 12.5 13.75 12.5 Ad of o 0 P300 / P320 / P400 / P405 ® I Maximum 99.5... ._ i_.%. . N N N Weighted Efficiency ._ 98.8 „.I % W LU LLI LLJ -------- Overvoltage Category I 11 F J , N_N_N_ OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLARE_DGE INVERTER) ' M U U w Maximum Output Current_ 15 Adc 21 W W W Maximum Output Voltage Fi0 85 Vdc p ~I-F- OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) O- N _ .. _ __. _-. ri Safety Output Voltage per vower Optimizer i 1 1 Vdc STANDARD COMPLIANCE ` EMC , 1. FCC Par Class 8 IEC61000-6-2,IEC61000.6-3 ® Safety .. IEC62109.1(class 11 sah tv),UL1741 1- Rolls __ _ Ycs __ _ _ INSTALLATION SPECIFICATIONS _ _ _ T Z zO y u 4 xaa Maximum Allowed System Voltage 1000 Vdc C6 U) Compatible Inverters All 50larfdile Single Phase and Three Phase inverters o M p LU 28 x 52 27,5 Dimensions(W x l x H) ...J. __ .15x5197x 1.08/ .., 35x5,97x 1331 Sx5.97x 189 mm/in O2 �H �.. , . 88q O W Weight(Indudmg cables) 770/1.) 930/2.05 930/205 gr/Ib ¢K of,, Input Connector , MC4Comparible - _ .... a U)tO Output Wire Type(Connector - 1.2/3.9 Double lnsuhted,MC4 Compatible } - 6 Dy Output Wife Length . 0.95/90 m/th Z Operating Temperatu a Range , -40 +85/_40•a185 'C/. Ratingprotection . .IP68U O Y Q a ... N • Rees STC Humidity.,4.Moaub Wunro•5% ..... .. .. > . aRelative Humidity d . � ... .. .. O NEOMO U A6P . ..... .... ...... . .. .� N i1.A U PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE 208V THREE PHASE 480V N A SOLAREDGE INVERTERm 0O _ Minimum String length g 10 t 1B U Z a Z - - (Power Optimizers) ' .. .... _, .. 0 K 0 a ... .... .. ... A. ..._. ...,.. o.. F Maximum String Length 25 25 I 50 i 3 (Power Opdmlzers) ._ ..... _ .... .. ...... .. U - Maximum Powerer String 5250 6000 12750, W Ly,l U Parallel Strings of Different lengths - - _ Yes Z t) or W Orientations W a PV power optimization at the module-level C 52 W ,t h�t,no«xe m,w reos wnhnaao/onaol^sUry>na�n o..r uanx c�r rn a a W -Up t0 25°'.more energy N Z - 5upzrror eificlent:y{99.5,) Z_ ZI - Mitigates a.l types of module mismatch losses,from manufacturing Tolerance to partial shading u Z flexible system design for maximum space utilization }} i - Fast Installation with a single bolt Y 3 W Next generation maintenance with module-level monitoring ( F X F - Module-level voltage shutdown for installer and firefighter safety m VSA - GERMANY ITALY - FRANCE - JAPAN - CHINA ISRAEL - AUSTRALIA www.solaredge.us DISCLAIMER:If an Ertors,DWe hies or Omissii—ioru m these drawl ------ ----— Y Ra appear� rags,spedf+cations or dher contract dacumerds;The Owner or General Contrador slmg the r,in rlob7y Deslgrte writing,of such error or omission.to the avant that the Owner or General Conhador falls to give such notice,before construction ardor fabrication of the work,the Owner or General Contractor will be held responsible to the result of any enors,discrepandes or omissions and the cost of rec*ng them. N.T.S I PV-P7 RAILS/GROUNDING SHEET co SmMoNT INSTALLATION GUIDE z SYSTEM GROUNDING BONDING CONNECTION GROUND PATHS `-�� sTsWnaP � f� '�6� �n �`/ I 'af' •�'•��'©.__�'rF' �f~�,O NNW- rex sariew-i t • 9� aAYQ. J , N N N 0 ate CO U)(1) w w w `f90i - RAIL L-FOOT /BONDING T-BOLT BONDING MID CLAMP ASSEMBLY co to U) s.,+„ad r,ao, r.n.,..r.aa a.mu,e„ x.w.,s n.M rra a.mP rale,.]Pa amara. r j y U) \ WEEBLUG CONDUCTOR-UNIRAC PM 0080025: 0+r wmtroam«„oro,n«,Trw+ Qw.,..amaa.n,m,,nra.„aa m s.ar — 6' Apply Anti Seize and insert a bolt in the aluminum nil and through the clearance Tana T.ea4,nu+ab L ma m nwna,a Sw snr.ua R—nor boaor 14—vw+N,aK hole in the stainless steel flat washer.Placethe stainless steel Rat washer on the bolt, ©NI ©mw,a+.m r.riT.wR oriented so the dimples will contact the aluminum rail.Place the lug portion on the bolt and stainless steel flat washer,Install stainless steel Rat washer,lock washer and ©a nut.Tighten the nut until the dimples are completely embedded into the rail and lug. F It n Z oW U- a ® 0 Y a WeEeLUG IoA IL—Luc) `....._ 1..� _-______. W 10 0 END CLAMP ASSEMBLY O OR N O ®� RACK SYSTEM GROUND ©s uXaalaor 11 „aamem,rae+,aw a N 6�. Z O �•n-� ®`rtro w,ea„0-11,Pill”eaomrce nn m m +e.. e,ir Oona LeMe,n rW am lug o mel T.1 MN N 1.1.r,fl,nalt,lien ©+Orna i�bol4nut.aE,N<I,mP to painaa± ILSCO LAY-IN LUG CONDUCTOR-UNIRAC P/N 008009P:Alternate Grounding Lug sora+aPP«was ca,a«i,a m wq Is—R,a sm.,a CV w -Drill and bolt lhru both rail walls per table. 0 wama.Mrl+yuaa9 ama.aamavas U I= O o �Z v o U 2 000 RAC - o z 00 _ U © ”' Q. ©2008 UNIRAC, INC. Installation Detail ' =W SolarMount Rail <'` BONDING RAIL SPLICE BAR Z y L-Foot Connection ��a'a�«"�" q. �m,raaa„ a.� }z p iu W Qwwa.mx+e.y�iAO•aa'a an„o-,n<aaw C7 m Q= a DISCLAIMER Han Errors, nciesorOmtssbns Y Discrepancies appear in these drawings,specifications or other contrail documents;The Owner or General Contractor shah notify the Designer,in writing,of such error or omission.In the event that the Owner or General Contractor falls to give such notice,before construction ar d er fabrication of the work,the Owner or General Contractor will be held responsible to the result of any errors,discrepancies or omissions and the cost of rec6tying them. t l ` N.T.S PV-P7A SM �'rQ A P P E N D I X G j 1 CLASS"A"FIRE CERTIFICAT ON - -------------------------------------------------------------------------------------------------------------------------------------------- The SOLARMOUNT system has been certified and Listed to the UL 2703 standard(Rack Mounting Systems and Clamping Devices for Ftat-Plate Photovoltaic Z Modules and Panels).This standard included electrical grounding,electrical.bonding,mechanical load and fire resistance testing. t9 S( In conducting these tests,specific modules are selected for their physical properties so that the certifications can be mostly broadly applied.The following lists O UQ Q ( LLI /! the specific modules that were tested and the applicability of those certifications to other modules that might come onto the market. v) c c 3 W Y Y Y In addition to UL 2703 certification,Uni.rac performs internal testing beyond the requirements ofcertification tests in order to establish system functional Limits, allowable loads,and factors of safety.These tests include functional system tests,and destructive toad testing. °D N N N Mechanical Load Test Modules System Level Fire Classification W W 1.1i The modules selected for UL 2703 mechanical load testingwere selected to The system fire class rating N N N y g requires installation in the manner specified in the represent the broadest range possible for modules on the market.The tests SOLARMOUNT Installation Guide.SOLARMOUNT has been classified to the system level ,n performed cover the following basic module parameters: fire portion of UL 1703. This UL 1703 classification has been incorporated into our UL Vi=i W W W • 60 cell framed modules only 2703 product certification. SOLARMOUNT has achieved Class A system Levet • Frame thicknesses greater than or equal to 1.2mm performance for steep sloped roofs when used in conjunction with type 1,type 2,type 3 _ y • Basic single and double wall frame ( p and type 10 module constructions.Class A system level fire performance is inherent in g profiles some complex n•and no additional the SOLARMOUNT design,frame profiles could require further analysis to determine g mitigationaired.The re tq applicability) classification rating is only valid on roof pitches greater measures are req 3 firer Khan 2:12(slopes 2 inches per foot,or 9.5 degrees). There is no required minimum or maximum height limitation Clear and dark anodized aluminum frames above the roof deck to maintain the Class A fire rating for SOLARMOUNT. • Certification Loads:SO psf up,113 psf down 7 c s M O O rKuauk Manufaotor¢rddu��worfa:i/sones Module Type System Levet Rail Module Mitigation O �r:n.a 'rslvr-egos Fire Rating Direction Orientation Required p W Cent ro9 otar Vt51QN C2 Type 1. Type East-West Landscape OR O 0 ¢a.Ce nt r,,aS sitar [:Scri�a GO cell 2.Type 3. 8a Glass A None Required O� Cent roS urar i-y.er iris GO can "p. 10 North-South Portrait H Orn S� og aCL O) U PAGE 1 NV'a o SM ®LAFIRE CODE COMPLIANCE NOTES ; O �� a C�00 ; � T INSTALLATION GUIDE ; PAGE s C] 3 A �� ------------------------------------------------------------------------------------------------------------------------------------- SYSTEM LEVEL FIRE CLASSIFICATION W wa r Thepystem fire class rating requires installation in the manner specified in the SOLARMOUNT Installation Guide.SOLARMOUNT has been classified to the system level fire onion of UL 1703. This UL 1703 classification has been incorporated into our UL 2703 product certification. SOLARMOUNT has achieved Class A system level ¢ "3 performance for steep sloped roofs when used in conjunction with type 1,type 2,type 3 and type 10 module constructions.Class A system level fire performance is Z inherent in the SOLARMOUNT design,and no additional mitigation measures are required.The fire classification rating is only valid on roof pitches greater than 2:12 Z Z (slopes 3 2 inches per foot,or 9.5 degrees). There is no required minimum or maximum height Limitation above the roof deck to maintain the Class A fire rating for N SOLARMOUNT. }W u a Module Type System Level Fire Rating Rall Direction Module Orientation Mitigation Required m a 8 a X 3 Type 1,Type 2, Type 3 &Type 10 Class A East-West Landscape OR Portrait None Required y North-South Landscape OR Portrait None Required . F DISCLAIMER If any Enos,Discrepancies or Omissions appear in these d --- swings,specifiptioLs or documents;The Owner or General Contractor strap notify the Designer,in writing,of such error or omission.In ti*event that the Owner or General Contractor falls to give such notice,before construction andfor fabrication of the work,the Owner or General Contractor will be held responsible to the result of airy enols,discrepancies or omissions and the cost of rectifying them. THIS EDGE TOWARDS ROOF RIDGE ITEM DESCRIPTION QTY. N.T.S PV-P8 NO. ATTACHMENTS SHEET 1 FLASHING,9"X 12"X.040",5052,MILL 1 2 QBLOCK,CLASSIC,A360.1 CAST AL,MILL 1 3 HANGER BOLT,PLAIN CENTER,5/16"x 6', 1 18-8 SS WASHER,FLAT, 19/64'ID x 7/8"OD x I/&' 6 EPDM 1 4 WASHER,SEALING, 5/16"ID X 3/4"OD, 1 z w Y RACKING COMPONENTS EPDM BONDED SS NOT INCLUDED N N 5 NUT,HEX,5/16-18,UNC-26, 18-8 SS 2 w Iii Iii Iii 12.00 7 WASHER,FENDER,5/16"ID X 1"OD, 18-8 SS 1 J ' v��, 5 r__-_+� mwww m m t11 �� 8 WASHER,SPLIT-LOCK,5/16"ID, 18-8 SS 1 „ mcnEn I 8 61 ';1 6 itIt 1.25 QO _ -- _ -;' �l-_—t 5 l zir 0 � o M ow 3.00 4 $2 3 0(o z w� oUoq,Go 9.00 n 3 c`4 0 2.25 2 a j � U 1 1 ��Z Z �3 Quick Mount PVR I TITLE: w a N w 3 U QMSE: QMPV E-MOUNT Z 2 �w z fyY/�w z WI a UNLESS OTHERWISE SPECIFIED: SIZE DRAWN BY: RAD REV C7 m ZQ= , Q1 DIMENSIONS ARE IN INCHES m V 0- X m TOLERANCES: A DATE: 9/12/2013 noremARY AND comroFNDAE r FRACTIONAL'-1/8 ME RIFOR MN CONTANEO N iNiS DRAWING G FNE SOLE PROPERTY OF QUICK MOUNT PV.ANY REPRODUCTION IN PARS OR AS DO NOT SCALE DRAWING TWO PLACE DECAMAL E.18 W A"OLENOWT I!WRMN PERMWON OF OUlCRMOUMPVISPROH.WTM. THREE PLACE DECIMAL !.125 SCALE:1:3 WEIGHT:0.9564 SHEET OF DISCLAIMER:M any Errors,Discrepancies or Omissions appear in these drawings,specifications or other contract documents;The Owner or General Contractor shag notify the Designer,in writing,of such enor or omission.In the event that the Owner or General Contractor fags to give such notice,before construction andfor fabrication of the work,the Owner or General Contractor will be held responsible to the result of any errors,discrepancies or omissions and the cost of rectifying them. GENERAL NOTES N.Ts PV P9 2011 NEC,CITYICOUNTY FD-MARKINGS,LABELS,AND WARNING LABELS WARNING SIGNS POWER • THIS ;� • WARNING � • •V• LTAIC SYSTEM REQUIRED ALSO SUPPLIED BY THE ELECTRICAL • •• ••EN-CIRCUIT VOLTAGE VdcC SOLAR SYSTEM, THE t� PHOTOVOLTAl A.Main Service Disconnect: •• • • ••CONDUCTOR • VOLTAGEQ • • • Z CAUTION UNGROUNDED AND OPERATING y� SOLAR ELECTRIC SYSTEM CONNECTED PLACED ON MAIN PANEL cyS AT ALL•J'BOXES,CON®.BOx DISCONNECTS DEVICE NOW •' J as a v -the marking may be placed 1.Residential buildings w 0 0 Q within the main service disconnect.The marking shall ENERGM,UNGROUNDED W W MAYBE WOSRING • (nY Y be placed on the outside cover t the main service PLACED ON DC disconnect is operable with the service panel dosed. ,n 2.Permanent labels shall be provided,no sharpie OUTPUT . INVERTER/1-DOCOKNECT WARNING ci o 0 marking wig be allowed within any main service panel or INVERTER N N N subpanel. • • • • HAZARDPHOTOVOLTAIC AC DIS • w til Ili 6i00 • • •• D J 3.All National Electric Code,and Fire Department requiredMAXIMIJIvIOPERATING CURRENT OVERCURRENT DEVICE NORMALLY •• • s CONDUCTORS labeling will be made of sunlight and weather-resistant material. •• • y g Labeling on disconnects,inverters and service panels will be PLACED ON MAIN PANEL 208 r made of an engraved,plastic material and be permanently NEAR GROUNDFAULTINDICATOR >> } attached to its respective device.All labeling shall be attached PLACED ON MAIN ELECTRICAL PANEL _ direly to those pieces of equipment STRING INVERTERS ONLY 6" �ro 4.Markings:Verbiage,Format,and Type of Material. a.Verbiage: N Required:6•x 6' Placard to go on Main Service Panel CAUTION WARNING SOLAR •• • r POWER TO THIS BUILDING ISWARNING j I y ALSO SUPPLIED BY THE 0 POTOVOLTAIC SOUR SYSTEM, PLACED ON MAIN ELECTRICAL PANEL ; c w DO NOT TOUCH TERMINALS. POWER 1 THIS BUILDINGALSO 1 •/ <O (L b.Format FOLLOWING 1 DISCONNECTS LOCATED` / • • • W \ � M (1)While lettering on a red background. U1 (2)"PHOTOVOLTAIC BREAKER"letters to be 118"minimum in NORTH PLACED ON INVERTER U height,All other Lettering to be 114"minimum in height (3)All letters shall be capitalized. NEC-N0.111CK2} 7d- (4)Arial or similar font,Non-bold (5)Reflective weather resistant material suitable for the • • a m r>>0 pp U enviroment(durable adhesive materials must meet this C-4 d 2'O requirement) ON ALL DC CONDUITS RACEWAY EVERY 10'&"J*BOX B. Marking Requirements on AC Condut.Raceways, C14Ir w Enclosures,Cable Assemblies,Combiners,and _ U O o junction boxes: Z 0 1. Markings:Placement,Verbiage,Format,and Type of hPHOTOVOLTAIC SCIA •• / >_d cT Material. Z!Y O U a.Permanent Placement:Markings shall be placed PLACED ON INTERIOR AND EXTERIOR DC CONDUIT,RACEWAYS, Z ci every 10 feet on all interior and exterior AC conduits, ENCLOSURES,CABLE ASSEMBLIES,JUNCTION BOXES,AND LTJ _ li raceways, enclosures,and cable assemblies,ati~ furP s,above and/or below enetretlons,and DISCONNECTS.MARKING SHALL BE PLACED ON INTERIOR AND w a junction boxes. EXTERIOR DC CONDUIT,RACEWAYS,ENCLOSURES AND CABLEFRONT 3 b.Verbiage: 170 ASSEMBLIES EVERY 10 FEET(30/8RNN),WITHIN 1 FOOT OF TURNS �Z CAUTION OR BENDS AND WRHIN 1 FOOT ABOVE AND BELOW PENETRATIONS AC SOLAR VOLTAGE OF ROOFICEILING ASSEMBLIES,WALLS OR BARRIERS. } Q� C.The following label to be placed on all AC Y v Z 1�i UZOdsconnecls (�m mQ=CAUTION • • • • m V d X SOLAR CIRCUIT DISCONNECT PLAQUE SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH PLACED ON AC DISCONNECT • A� _ POP-RIVETS OR SCREWS DISCLAIMER:If any Errors,Disarepancies or Omissions appear in these --—--- ------ drawings,spectifkxtions or other txxttrad documents;The Owner or General Contractor shall notify Ore Desigrier,in writing,of such error or omission.In the event that the Owner or General Contractor falls to give such notice,before construction ardor fabrication of the work,the Owner or General Contractor will be held resporLsible to the result of any errors,d1wepanaes or omissions and the cost of rectifying them.