Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Building Permit #455-2011 - 1780 OSGOOD STREET 5/1/2018
TOWN OF NORTH ANDOVER APPLICATION FOR PLAN EXAMINATION Permit NO: 55 o2o// Date Received Date Issued: IMPORTANT:Applicant must complete all items on this page i LOCATION 7k() 0S Cl-0©0 S Print U PROPERTY OWNER \I �Z �N Unit� Print MAP NO: PARCEL: ZONING DISTRICT: Historic District yes no Machine Shop Village yes no 100 year-old structure yes no TYPE OF IMPROVEMENT PROPOSED USE Residential Non- Residential ❑ New Building ❑ One family ❑Addition ❑Two or more family ❑ Industrial -B'Alteration No. of units: ,B-Eommercial ❑ Repair, replacement ❑Assessory Bldg ❑ Others: ❑ Demolition ❑ Other 0 �eptic ® V' ell ® oodplain D We lands ® Water-shed D stnct ,;a er1_Se"wer DESCRIPTION OF WORK TO BE PERFORMED: (Identification Please Type or Print Clearly) OWNER: Name: Phone: Address: CONTRACTOR Name: 1 CW (IP 11V C Phone: qzk a.� qY Address: 3s 1 !�J_W 0PD zkZ ��C �� L� , G w-7vo Supervisor's Construction License: 7 3 Exp. Date: Z— Home Improvement License: Exp. Date: ARCHITECT/ENGINEER Phone: Address: Reg. No. FEE SCHEDULE.BULDING PERMIT.•$92.00 PER$9000.00 OF THE TOTAL ESTIMATED gosrBASED ON$125.00 PER S.F. Total Project Cost: $ C�b a FEE: $ zS Check No.: i 03 o)-d Receipt No.: c>2 -� NOTE: Persons contracting with unregistered contractors do not have access to the guaranty fund Sig at a ofAg t/O erg` ' " � 5'ig atu ofco tra o 'r Plans Submitted ❑ Plans Waived ❑ Certified Plot Plan ❑ Stamped Plans ❑ TYPE OF SEWERAGE DISPOSAL Public Sewer ❑' Tanning/Massage/Body Art ❑ Swnnmmg Pools ❑ Well ❑ Tobacco Sales ❑ Food Packaging/Sales ❑ Private(septic tank,etc. ❑ Permanent Dumpster on Site ❑ THE FOLLOWING SECTIONS FOR OFFICE USE ONLY INTERDEPARTMENTAL SIGN OFF - U FORM DATE REJECTED DATE APPROVED PLANNING & DEVELOPMENT ❑ ❑ COMMENTS CONSERVATION Reviewed on Signature COMMENTS I HEALTH Reviewed on Signature COMMENTS Zoning Board of Appeals: Variance, Petition No: Zoning Decision/receipt submitted yes d Planning Board Decision: Comments Conservation Decision: Comments Water& Sewer Connection/Signature&Date Driveway Permit DPW Town Engineer: Signature: Located 384 Osgood Street FIRE DEPARTMENT -Temp Dumpster on site yes no Located at 124 Main Street Fire Department signature/date COMMENTS i Dimension Number of Stories: Total square feet of floor area, based on Exterior dimensions. Total land area sq. ft.: ELECTRICAL: Movement of Meter location, mast or service drop requires approval of Electrical Inspector Yes No i DANGER ZONE LITERATURE: Yes No MGL Chapter 166 section 21A—F and G min.$10041000 fine I NOTES and DATA— For department use I II i ❑ Notified for pickup - Date Doc:.Building Permit Revised 2011 June/mi Y Building Department The following is a list of the required forms to be filled out for the appropriate permit to be obtained. Roofing, Siding, Interior Rehabilitation Permits o Building Permit Application ❑ Workers Comp Affidavit o Photo Copy of H.I.C. And/Or C.S.L. Licenses o Copy of Contract ❑ Floor Plan Or Proposed Interior Work ❑ Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit Addition or Decks o Building Permit Application o Certified Surveyed Plot Plan a Workers Comp Affidavit ❑ Photo Copy of H.I.C. And C.S.L. Licenses a Copy Of Contract ❑ Floor/Crossection/Elevation Plan Of Proposed Work With Sprinkler Plan And Hydraulic Calculations (If Applicable) o Mass check Energy Compliance Report (If Applicable) o Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit New Construction (Single and Two Family) ❑ Building Permit Application o Certified Proposed Plot Plan o Photo of H.I.C. And C.S.L. Licenses o Workers Comp Affidavit o Two Sets of Building Plans (One To Be Returned) to Include Sprinkler Plan And Hydraulic Calculations (If Applicable) o Copy of Contract a Mass check Energy Compliance Report o Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg .Permit In all cases if a variance or special permit was required the Town Clerks office must stamp the decision from the Board of Appeals that the appeal period is over. The applicant must then get this recorded at the Registry of Deeds. One copy and proof of recording must be submitted'with the building application Doc: Doc.Building Permit Revised 2008mi d CT Location 1 Q No. 11 Date 140RTM TOWN OF NORTH ANDOVER a H Certificate of Occupancy $ �NUs Building/Frame Permit Fee $ � Foundation Permit Fee $ Other Permit Fee $ TOTAL $ Check # 4'd0.--�a0 24859 Building Inspector NORTH TO" of o o , over, Mass.,LAKE COCHICHEWICK S� 0RATED BOARD OF HEALTH PERMIT T D Food/Kitchen Septic System BUILDING INSPECTOR THIS CERTIFIES THAT.............X.......... ............p..":iw... ...................................................................... 0............. Foundation has permission to erect....... .............. ...... buildings on ....... ..........0. a !QO .... an:. Rough to be occupied as............... .. ....... ........OPW.`. .f/* ........ .7.............. .. . . " Chimney ............................................. . provided that the person accepting this permit shall in every respect conform to the terms of the application on file in Final this office, and to the provisions of the Codes and By-Laws relating to the Inspection, Alteration and Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR VIOLATION of the Zoning or Building Regulations Voids this Permit. Rough Final PERMIT EXPIRES IN 6NTBS ELECTRICAL INSPECTOR UNLESS CONSTRUC O S Rough ........................... ............................................................. Service BUILDING INSPECTOR Final Occupancy Permit Required to Ocmpy Building GAS INSPECTOR Display in a Conspicuous Place on the Premises — Do Not Remove Rough Final No Lathing or Dry Wall To Be Done Until Inspected and Approved by the Building Inspector. Burner' FIRE.DEPARTMENT Street No. SEE REVERSE SIDE Smoke Det. TOWN OF NORTH ANDOVER 1600 OSGOOD STREET Building 20 Suite 2-36 NORTH ANDOVER MA 01845 FURNACES, BOILERS, ROOF TOP UNITS, AIR CONDITIONERS, EMERGENCY GENEREATORS ZD l l Date . 1913 The undersigned applies for a permit to install the following at: Location Owner of premises J IT—r` f -EA+)® Address ago ma b Name of mechanic::9O�LT-r'F u" pm L— Address �i,57 D(Z I Building occupied for 0 Material of building Kind of fuel_ rG J7ANE Chimney No. Of flues _Size !f Chimney Thickness Lining If steel stack location Diameter Height DESCRIPTION OF HEATING APPARATUS Kind of heater4?"Aif how many make61C_.1.cw g BTU Input b �� Location in building Protected against fire as required How protected See the State Code (Pertaining to Chimneys, Smokestacks and Heating Apparatus) ROOF TOP UNITS OR EMERGENCY GENERATORS Make Weight Dimension Length Width Height Location of building how supported Size of roof timbers Material of roof timbers Span of roof ' ers Distance on center Protected,against fire as required How protected AIR CONDITIONS Kind of apparatus make HVAC FORM REVISED 11.04 Sheet Metal Commercial Guidelines/Life Safety/Critical Systems Inspection Checklist Yes No N/A, Set of stamped engineering documents and detailed description of / mechanical system to be installed has been provided ✓ All workers performing sheet metal work onsite has valid Massachusetts sheet metal / license All sheet metal work being performed with proper journeyperson-to-apprentice ratios Fire dampers with access door properly installed and checked for operation Smoke and combination fire/smoke dampers rs with access doors properly installed- actuator checked for proper operation (May also be verified by fire department during J fire alarm testing) Duct smoke detectors with access doorsp p yro erl located i (May also be verified by fire department during fire alarm testing) Smoke/atrium exhaust systems installed and operation verified May also be verified by fire department during fire alarm testing) Stair pressurization systems installed(where required) and operation verified(May also be verified by fire department during fire alarm testing) /Grease/kitchen hood exhaust system installed with all seams and connections welded airtight with properly located cleanouts. Proper clea;`ances, fire rated enclosures and ressure testing required. -- ;y eis,;}ic reNu.�aints installt?_xJ3iFtdrequired bn equipment and c - . , _ — Duct penetrations in fire'rate4 wall:,and floors sealed Metal roofing systems installed watertight usingroper materials and fasteners p JFlexible duct nuns installed 6'-0"maximum length Ductwork installed using proper hanger spacing, hanger stock,threaded rod and angle / iron Ductwork/plenum connections sealed substantially airtight Ductwork insulated b means of external covering or internal linin / y g g Volume dampers installed for each supply air branch duct New/clean-properly sized filters installed d(final inspection) Testing and Balancing report complete(final sign-off) r' � Building Analysis Job: 178 Osgood,Andover , Date: 08/11/2011 p ., .a SOpD' Op pG Entire Building By: Warren Estes American Air Tewksbury,MA Project • • For: JTI Contractors 1780 Osgood Street,Andover, MA Design C• • • Location: Indoor: Heating Cooling Boston, MA, US Indoor temperature (°F) 70 75 Elevation: 16 ft Design TD(°F) 58 13 Latitude: 42°N Relative humidity(%) 39 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 24.5 26.0 Dry bulb(°F) 12 88 Infiltration: Dailyrange (°F) - 15 ( L ) Method Simplified Wet bulb(°F) - 72 Construction quality Average Wind speed (mph) 15.0 7.5 Component Btuh/ft2 Btuh %of load Walls 3.6 5157 17.7 wall Humidification Glazing 31.7 5839 20.0 Doors 0 0 0 Ceilings 1.6 3259 11.2 Floors 0 0 0 Infiltration 57.9 10657 36.5 °� Ducts 0 0 \Infiltration Piping 0 0 Humidification 4248 14.6 Ventilation 0 0 Ceilings Adjustments 0 Total 1 1 291601 100.0 Jul 1700 LDT Component Btuh/ftz Btuh %of load Walls 2.0 2849 8.7 wall Glazing 42.3 7789 23.8 Doors 0 0 0 Ceilings 2.0 4124 12.6 Gaare� Floors 0 0 0 Infiltration 8.4 1544 4.7 Internal Gains Ducts 0 0 Ventilation 0 0 Internal gains 16388 50.1 Blower 0 0 Adjustments 0 Ceilings Total 32694 100.0 Infiltration Latent Cooling Load=3178 Btuh Overall U-value=0.043 Btuh/ft2-0F Data entries checked. 2011-Nov-09 09:56:18 .a �! (I�1Q' L� Right-Suite®Universal 8.0.18 RSU15053 Page 1 Project1.rup Calc=CLTD Front Door faces: N � i ,j"'" Component Constructions Job: 178 Osgood,Andover tlaTlSf�if4 M Date: 08/11/2011 Entire Buildingy B Warren Estes American Air Tewksbury,MA Project • • For: JTI Contractors 1780 Osgood Street,Andover, MA Design Conditions Htg Clg Htg Clg Outside db(°F) 12 88 Inside db(°F) 70 75 Outside RH (%) 80 46 Inside RH (%) 39 50 Outsidewb(°F) 20 72 Inside wb(°F) 55 63 Dailyrange(°F) - 15 Design TD(°F) 58 13 Moisture diff. (gr/Ib) 24.5 26.0 Construction descriptions or Area U-value UA Loss Gain ft' (BtuhW-°F) (Btutd'F) (Btuh) (Btuh) Walls Frm wall,mtl ext,r-19 cav ins,5/8"gypsum board int fnsh,2"x6" ne 560 0.06 35.3 2040 703 wood frm se 240 0.06 15.1 874 363 sw 376 0.06 23.7 1369 1218 nw 240 0.06 15.1 874 565 all 1416 0.06 89.4 5157 2849 Partitions (none) Windows htg clg htg clg 2 glazing,clr low-e outr,air gas,mtl/w brk frm mat,clr innr,1/4" ne 48 0.55 / 0.55 26.4 / 26.4 1523 1224 gap,1/8"thk se 24 0.55 / 0.55 13.2 / 13.2 762 774 sw 72 0.55 / 0.55 39.6 / 39.6 2285 4161 nw 40 0.55 / 0.55 22.0 / 22.0 1269 1630 all 184 0.55 / 0.55 101 / 101 5839 7789 Doors (none) Ceilings Rf/clg ceiling,mill roof mat,mtl cons,suspended,acoustical int fnsh, 2100 0.03 56.5 3259 4124 r-30 r,dead air pinm Floors (none) t , � � r 2011-Nov-09 09:56:18 �- Right-Suite®universal 8.0.18RSU15053 Page 1 i /C<>', Project1.rup Calc=CLTD Front Door faces: N H f' ,i Job: 1780sgood,Andover y1' l '1141d�lfl4 Right-Suite® Universal Short Form g Date. 08/11/2011 Entire Buildingy: B Warren Estes American Air Tewksbury,MA Project • • For: JTI Contractors 1780 Osgood Street,Andover, MA Htg Clg Htg Clg Outside db (°F) 12 88 Inside db (°F) 70 75 Outside RH (%) - 46 Inside RH N - 50 Outside wb (°F) - 72 Inside wb (°F) - 63 Daily range (°F) - 15 Design TD (°F) 58 13 Moisture diff. (gr/Ib) - 26 Heating Equipment Cooling Equipment Make Make Model Model Type Gas furnace Type Split AC Efficiency 80 AFUE COP/EER/SEER 0 Heating Input 0 MBtuh Sensible Cooling 0 MBtuh Heating Output 0 MBtuh Latent Cooling 0 MBtuh Humidifier 11.4 gpd Total Cooling 0 MBtuh Leaving Air Temp 70.0 °F Leaving Air Temp 55.0 °F Actual Heating Fan 1487 cfm Actual Cooling Fan 1487 cfm Equipment Location Entire Building System Type PEAKCV Fan Motor Heat Type PACKAGE Fan&Motor Combined Efficiency 0 % Static Pressure Across Fan 0 in H2O NAME I Area I Heat I Sensible I LatentI Htg I cfm Clg I Time ft2 Loss Gain Gain cfm Entire Space I 2100 I 29160 I 32694 I 3178 I 14871 1487 I Jul 1700 LDT Entire Building 2100 29160 32694 3178 1487! 1487 Jul 1700 LDT WA'1 fIt5O7 2011-Nov-0909:56:18 Rig Universal8.0.18 RSU15053 Page 1 Project1.rup Calc=CLTD Front Door faces: N Y g '1 Ri ht-Suite® Universal Load Summary Job: 178 ,Andover y�tLlt"�iH' is�frd Date: 08/11/2011112011 Entire Building By: Warren Estes American Air Tewksbury,MA Project For: JTI Contractors 1780 Osgood Street,Andover, MA Zone: Entire Building COOLING LOAD 1. DESIGN CONDITIONS at Jul 1700 LDT Peak load at Jul 1700 LDT Inside: 75 °F Outside: 88 °F TD: 13 °F RK 46 % MoistDiff: 26.0 gr/Ib Mult: 0 Ins.wb 63 °F Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 6544 - 3. TRANSMISSION GAINS Sensible 8217 Walls: 2849 - - Glass: 1245 - - Doors: 0 - - Partitions: 0 - - Floors: 0 - - Ceilings: 4124 4. INTERNAL HEAT GAIN Sensible Latent 16388 1200 Occupants: 1500 1200 - - Lights: 11288 - - - Motors: 0 - - - Appliances: 3600 0 - - 5. INFILTRATION: Outside air cfm: 112 1544 1978 6. SUBTOTAL: Space load Sensible Latent 32694 3178 Envelope 32694 3178 - - Less external 0 - - - Redistribution 0 0 - - 7. SUPPLY DUCT 0 - 8. SUBTOTAL: Space load+supply duct 32694 - Actual cfm: 1487 at supply TD: 20 - - 9. VENTILATION: Make-up air cfm: 0 0 0 10. RETURN AIR LOAD: Lighting+ plenum(net) 0 - 11. RETURN DUCT 0 - 12. TOTAL LOADS ON EQUIPMENT 32694 3178 HEATING LOAD 13. DESIGN CONDITIONS Mult: 0 Inside: 70 °F Outside: 12 T TD: 58 °F 14. TRANSMISSION LOSSES 14256 Walls: 5157 - Glass: 5839 - Doors: 0 - Partitions: 0 - Floors: 0 - Ceilings: 3259 - 15. INFILTRATION: Outside air cfm: 168 10657 16. SUBTOTAL: Space load 24913 Envelope 24913 - Less external 0 - Less transfer 0 - Redistribution 0 - 17. SUPPLY DUCT: 0 18. VENTILATION: Make-up air cfm: 0 0 19. HUMIDIFICATION 4248 Piping 0 20. RETURN DUCT 0 21. TOTAL HEATING LOAD ON EQUIPMENT 29160 Wr! � � � 2011-Nov-0909:56:18 Right-Suite®Universal 8.0.18 RSU15053 Page 1 Projectt.rup Calc=CLTD Front Door faces: N