Building Permit #171-15 - 24 DARTMOUTH STREET 8/18/2014 (3)
. r NORTH BUILDING PERMIT O�tt'E' ,6,6 TOWN OF NORTH ANDOVER o� h.."'- " 0� APPLICATION FOR PLAN EXAMINATION w Permit No#: Date Received �R"CpRATE �SSACHV`-'fit Date Issued: IMPORTANT: Applicant must complete all items on this page LOCATION Print PROPERTY OWNER Print 100 Year Structure yes no MAP PARCEL: ZONING DISTRICT-Historic District yes no Machine Shop Village yes no TYPE OF IMPROVEMENT PROPOSED USE Residential Non- Residential ❑ New Building ❑ One family ❑Addition ❑ Two or more family ❑ Industrial ❑Alteration No. of units: ❑ Commercial ❑ Repair, replacement ❑Assessory Bldg ❑ Others: ❑ Demolition ❑ Other ❑Septic ❑Well ❑ Floodplain ❑Wetlands ❑ Watershed District ❑Water/Sewer DESCRIPTION OF WORK TO BE PERFORMED: Identification- Please Type or Print Clearly OWNER: Name: Phone: Address: Contractor Name: Phone: Address: Supervisor's Construction License: Exp. Date: Home Improvement License: Exp. Date: ARCHITECT/ENGINEER Phone: , Address: Reg. No. FEE SCHEDULE:BOLDING PERMIT:$12.00 PER$1000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PER S.F. Total Project Cost: $ FEE: $ Check No.: Receipt No.: NOTE: Persons contracting with unregistered contractors do not have access to the guaranty fund ,Signature of Agent/Owner Signature of contractor Location ?— � ���� �^ ''` A No. —1 5 Date . - TOWN OF NORTH ANDOVER 19 Certificate of Occupancy $ Building/Frame Permit Fee $ t m Foundation Permit Fee $ Other Permit Fee $ TOTAL $ Check# �Q Building Inspector - F At,O. ,'A o,solarCitt . MIR 3055 Clearview Way, San Mateo, CA 94402 ; MYMASSOU MI (888)-SOL-CITY (765-2489) (www.solarcity.com CIVIL No. Project/Job# 018728th' 1 RE: Installation Approval Letter Project: Balogh Residence d 24 Dartmouth St Amir Massoumi North Andover, MA 01845 2014.11 .08 15:11 :56 -08'00' To Whom It May Concern, On the above referenced project,the roof structural framing has been reviewed for additional loading due to the-installation of the solar PV addition to the roof.The structural review, including the plans and calculations only apply to the section of roof that is directly supporting the solar PV system and its supporting elements. The capacity of the structural roof framing directly supporting the additional gravity loading due to the solar panel supports and modules had been reviewed and determined to be in accordance with the requirements of the MA Res.Code,8th Edition. Plans and calculations were stamped&signed with my professional engineer's seal. The work has been completed in accordance with the provisions of the approved permits of the applicable code. Should you have any further questions or requirements pertaining to this project, please do not hesitate to contact me. Sincerely, Amir M assoumi P.E. Civil Engineer Direct: 650.963.5611 email: amassoumi@solarcity.com 3055 Clearview Way San Mateo,CA 94402 T(650)638-1028 (888)SOL-CITY F(650)638-1029 solarcity.com AZ ROC 243771.CA C:SLB 8H7104,GO CC 804+„Of H-G CFiUU8,Dv HC i DC HS 711014.48 -.CC2977U,MA Ht:le-rW2.MID MHiC 128948.Cd)}3k'tiUR1Esti8(!G, OM CCB 180.498,PAOi7343,Th TDLR 2700G,VIA GCL:SCLAAC'91907.z';2113 SO!,'Gity.Al light; Town of tAndover No. f ver, Mass p coc"Ic" WIC c . / A0RAT1& S U BOARD OF HEALTH Food/Kitchen PERT LD Septic System THIS CERTIFIES THAT ................ .......... ........ ........ ............................................................... BUILDING INSPECTOR „� sk Foundation has permission to erect ......................... buildings on .... .... .. .......................... .............. 1 Rough to be occupied as ....... ...... ...� ... .. .r& .....Z3...Pa!ca.'s.............................. Chimney provided that the person accepting this permit shall in every r�pect conform to the terms of the application Final on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection, Alteration and Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR VIOLATION of the Zoning or Building Regulations Voids this Permit. Rough Final PERMIT EXPIRES IN 6 MONTHS ELECTRICAL INSPECTOR -UNLESS CONSTRUCTION STS Rough Service .............................. ........................................... Final BUILDING INSPECTOR GAS INSPECTOR Occupancy Permit Required to Occupy Building Rough Display in a Conspicuous Place on the Premises — Do Not Remove Final No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. Burner Street No. Smoke Det. • ' The Commonwealth of Massachusetts 02 Department of Industrial Accidents Office of Investigations IF 600 Washington Street Boston, MA 02111 www mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): JSolarCity Corporation Address: 13055 Clearview Way City/State/Zip: an Mateo,CA,94402 Phone 4: 888-765-2489 Are you an employer? Check the appropriate box: Type of project(required): 1.M 1 am a employer with 5000 4. 10 1 am a general contractor and 1 6 New construction employees(full and/or part-time).* have hired the sub-contractors 2. 1 am a sole proprietor or partner- listed on the attached sheet. + 7• Remodeling ship and have no employees These sub-contractors have 8. ® Demolition working for me in any capacity. workers' comp. insurance. 9• Building addition [No workers' comp. insurance 5. ® We are a corporation and its 10.El Electrical repairs or additions required.] officers have exercised their 3. 1 am a homeowner doing all work right of exemption per MGL I I.E3 Plumbing repairs or additions myself. [No workers' comp. c. 152, §1(4),and we have no 12.Un Roof repairs insurance required.] # employees. [No workers' 13.OM Other Solar comp. insurance required.] Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. tContractors that check this box must attached an additional sheet showing the name of the sub-contractors and their workers'comp.policy information. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: [Liberty Mutual Insurance Company Polio #or Self-ins. Lin.#: 766 066265023 9/7/14 Y Expiration Date: 7- :1 - f Job Site Address: City/State/Zip: r-[--_ t 1711 t Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties of perjury that the information provided above is true and correct Signature: e Date: Phone#: 888-765-2489 Official use only. Do not write in this area, to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1. Board of Health 2.Building Department 3.City/Town Clerk 4. Electrical Inspector 5. Plumbing Inspector 6.Other ('nnt�ct Parenn• 016---u. f o�a CERTIFICATE OF LIABILITY INSURANCE O8 "za�"Y"' / 08121/23 3 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER 0726293 1-415-546-9300 C ACT Brendan Arthur J. Gallagher i Co. NAME: - - Quinlan Insurance Brokers of California, Inc., License #0726293 PHONE AIC N,W): 415-536-4020 ���.-- 1255 Battery Street #450 EMAIL L -) ADDRESS: brandan_guinlan@ajg.com San Francisco, CA 94111 INSURER(S)AFFORDING COVERAGE i NAIC0 -- ------ _ _ ___ __ __ IN A: LIBERTY NOT FIRE INS 00 23035 INSURED LIBERTY INS CORP 142404 SolarCity Corporation INSURER e: _ -_ _ -_ `- _- INSURER C; 3055 Clearview Flay ER D: _-- San Mateo , CA 94402 INSURER E: INSURER F: I COVERAGES CERTIFICATE NUMBER: 35272277 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE I ISTED BFLOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REOUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES-LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR A661.SUER' - " LTR TYPE OF INSURANCE f POLICY NUMBERA POLICY EFF POLICY EXP- -— MIDD/YYYY MM1DD LIMITS'GENERAL LIABILITY T82661066265053 09/01/1 09/01/14 EACIIOCCURRENCE S 1,000,000 . X y COMNERCtALGENERALLIABILITY I Ab1A' FN`Fi) 100,000 4) PREMISES(Fe ouunvnan S CLAMS-MADE I X-f OCCUR P X (Arryonsporson) 10,000 s + % Deductible: $25,000 MEOE [f�RSONAL d ADV INJURY i 1,000,000 I tGF.NERALAGGREOATE 52,000,000 GEN'/AGGRCGATC LIMIT APPLIES PER 1 PRODIICTS-COMA/OP AGO f 2,000,000 X POLICY J_tPRn• I LOC __ . A AUTOMOBILE LIABILITY 0 I COMBINED SINGLE LIMIT $ I X ANY AUTO i IEa aoddmg _ ; 1,000,000 ALL OWNED SCHEDULED BODILY INJURY(Pat person) $ AUTOS ( _ AUTOS BODILY INJURY(Per ecciderd) $ HIRED AUTOS NON-OWNED AUTOS 'PROPERTY DAMAGE S �a✓�Xlay - S UMBRELLA LIAROCCUR I I EXCESSLUIe _ CLAIMS-MADE: EACH OCCURRENCE $) f --- — (AGGREGATE _ EEO RETENTIONS B WORKERS COMPENSATION NC7661066265033 WC STATU• OTM• S AND EMPLOYERS'LIABIUTY YIN (FII Retr 109/01/13 09/01/14 X�xQ LIMI B ANY PROPRIETOWPARTNEWEXECUTiVE�I�y � NA766DO66265023 (Ded) 09/01/13 09/01/14 OFFICFRIMEMRFR FXCI UDEn? L" J NIA E L EACH ACCIDENT $ 1,000,000 (Mandatory M NN) E.L.DISEASE•EA EMPLOYE. S i,000,000 II yes.descnbe under , DESCRIPTION OF OPERATIONS below E L DISEASE-POLICY LIMIT $ 1,000,000 i DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (Attach ACORD 141,Additional Remarks Schedule,If mon space Is r"Wred) Proof Of Insurance. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Evidence of Insurance Only THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE;POLICY PROVISIONS AUTHORIZED REPRESENTATIVE A 1988-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010105) The ACORD name and logo are registered marks of ACORD satyasan 35272277 0j// 1416-WI(C11 i Office of Consumer Affairs and Business Regulation f• � t 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 168572 Type: Supplement Card SOLARCITY CORPORATION Expiration: 3/8/2015 CRAIG ELLS -- 24 ST. MARTIN STREET BLD 2 UNIT 11 - - - - -- - - -- ---- MARLBOROUGH, MA 01752 Update Address and return card.Mark reason for change. sc a, Co 4010 rr r t [—] Address �� Renewal F] Employment CI Lost Card Office of Consumer Affairs&Business Regulation License or registration valid for individul use only 5 46ME IMPROVEMENT CONTRACTOR before the expiration date. If found return to; l t 'i; Office of Consumer Affairs and Business Regulation + a_ Registration: 168572 Typc10 park Plaza-Suite 5170 Expiration: 3/8/2015 Supplement :ard Boston,MA 02116 SOLARCITY CORPORATION CRAIG ELLS , 7 u - 24 ST MARTIN STREET BLD 2UNI65 Ib ALBOROUGH,MA 01752 Undersecretary NojvlFeid without signature Massachusetts • Department of P.,011E satet, Board of Building Regulations :1nd St:lnaaras t -11 11 Ilk 11-m "ul#(I t Is r1y cense CS-107663 4 CRAIG ELLS f 206 BAKER STREET' Keene NH 03431 I ,1+mnr„11111•. 08/29/2017 i I I nIlltr' C1111111 Office of Consumer Affairs d Business Regulation 7..° 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 168572 Type: Supplement Card SOLAR CITY CORPORATION Expiration: 3/8/2015 ASTRID BLANCO - -- ----- — 24 ST. MARTIN STREET BLD 2 UNIT 11 -- - MARLBOROUGH, MA 01752 Update Address and return card.Mark reason for change. SCA 1 0 2W-0511 Address L-1 Renewal Employment CI Lost Card ""' Jprnce of Consumer Affairs&Business Regulation License or registration valid for individul use only j� ME IMPROVEMENT CONTRACTOR before the expiration date. If found return to: Office of Consumer Affairs and Business Regulation T egistration: 168572 Type: 10 Park Plaza-Suite 5170 'i Expiration: 3/8/2015 Supplement Card Boston,MA 02115 SOLAR CITY CORPORATION ASTRID BLAN T 24 ST MARTIRTIS N STREET BLD 2UNI WkBOROUGH,MA 01752 Undersecretary Not valid without signature F DocuSign Envelope ID:FBB0641D-E650-4749-81F2-2E8D1F31A69F moo 50la1'Clty Power Purchase Agreement Amendment Congratulations! Your system design is complete and you are on your way to clean,more affordable energy.We estimate that your System's first year annual production will be 7,016 kWh and we estimate that your average first year monthly payments will be$79.39. Over the next 20 years we estimate that your System will produce 133,842 kWh.We also confirm that your electricity rate will be$0.1358 per kWh,fixed for the next 20 years(i.e.electricity rate$0.1358 and tax rate$0.0000). Your Details Exactly as it appears on your utility bill Customer Name&Address Customer Name Service Address Lajos P Balogh 24 Dartmouth St 24 Dartmouth St North Andover,MA 01845 North Andover,MA 01845 As soon as you acknowledge the above design and production details by signing below,we will schedule your installation.If you have any questions or concerns please contact your Sales Representative. Customer's Name: Lajos P Balogh SolarCity SOLARCITY APPROVED DocuSigned by: � t-1 6S r bAthf� 7/23/2014 Signature: EVNOON RIVE.CEO Signature Date (PPA)Power Purchase Agreement Customer's Name: `SOIarCI1C Date: 7/22/2014 Signature Date 3055 CLEARVIEW WAY, SAN MATEO, CA 94402 888.SOL.CITY 1888.765.2489 ( SOLARCITY.COM MA HIC 168572/MA LIC. MR-1136 r Version #37.4 �"'N s,5 � olarQt . y4�At!F f 3055 Clearview Way, San Mateo, CA 94402 (888)-SOL-CITY (765-2489) I www.solarcity.com - ANTI R Ci MASSOUMI July 16, 2014 0 CIVIL Project/Job # 018728 NO.5 $55 RE: CERTIFICATION LETTER Project: Balogh Residence 24 Dartmouth StUrgWslgneoloy-A",lassou North Andover, MA 01845 Dato:2014.07.1819:24:44-07'00' To Whom It May Concern, A jobsite survey of the existing framing system was performed by a site survey team from SolarCity. Structural review was based on site observations and the design criteria listed below: Design Criteria: -Applicable Codes = MA Res. Code, 8th Edition,ASCE 7-05,and 2005 NDS - Risk Category = II -Wind Speed = 100 mph, Exposure Category C -Ground Snow Load = 50 psf - MP1: Roof DL = 8.5 psf, Roof LL/SL = 35 psf(Non-PV Areas), Roof LL/SL = 35 psf(PV Areas) Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.33365 < 0.4g and Seismic Design Category(SDC) = C< D On the above referenced project,the structural roof framing has been reviewed for loading from the PV assembly on the roof.The structural review only applies to the section(s)of the roof that directly supports the PV system and its supporting elements.After this review it was determined that the existing structure is adequate to carry the PV system loading. I certify that the structural roof framing and the new attachments that directly support the gravity loading from PV modules have been reviewed and determined to meet or exceed requirements of the MA Res. Code, 8th Edition. Please contact me with any questions or concerns regarding this project. Sincerely, Amir Massoumi, P.E. Civil Engineer Direct: 650.963.5611 email: amassoumi@solarcity.com 3055 Clearview Way San Mateo,CA 94402 T(650)638-1028 (888)SOL-CITY F(650)638-1029 solarcity.com , s, ,. .. .. •� . ., a .. 07.16.2014 NN% TM Version#37.4 �c;5®�arC t Sleek Mount PV System Structural Design Software PROJECT INFORMATION &TABLE OF CONTENTS Project Name: Balogh Residence AHJ: North Andover Job Number: 018728 Building Code: MA Res. Code, 8th Edition Customer Name: Balogh, Lajos P Based On: IRC 2009/IBC 2009 Address: 24 Dartmouth St ASCE Code: ASCE 7-05 City/State: North Andover, MA Risk Category: II Zip Code 01845 Upgrades Req'd? No Latitude/Longitude: 42.677608 -71.130460 Stamp Req'd? Yes SC Office: Wilmington PV Designer: Asif Chowdhury Calculations:I Jesus Santiago EOR:I Amir Massoumi P.E. Certification Letter 1 Project Information, Table Of Contents, &Vicinity Map 2 Structure Analysis (Loading Summary and Member Check) 3 Hardware Design (PV System Assembly) 4 Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.33365 < 0.4g and Seismic Design Category(SDC) = C < D 112-MILE VICINITY MAP 114 • 60 i 133 • 125 114 • Haverhill St StHaverh 133 2. • • •g- Commonwealth • /tts EOE& D• • • - 24 Dartmouth St, North Andover, MA 01845 Latitude: 42.677608,Longitude: -71.13046,Exposure Category:C STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK - MP1 Member Properties Summary MP1 Horizontal Member Spans Rafter Pro erties Overhang 1.16 ft Actual W 1.50" Roof System Properties San 1 13.79 ft Actual D 9.25" Number of Spans(w/o Overhang) 1 San 2 Nominal Yes Roofing Material Comp Roof San 3 A 13.88 in.-2 Number of Layers(Comp Only) 1 Layers San 4 SX 21.39 in.^3 Re-Roof to 1 Layer of Comp? No San 5 I 98.93 in.^4 Plywood Sheathing Yes Total Span 14.95 ft TL Defl'n Limit 120 Board Sheathing None PV 1 Start 2.00 ft Wood Species SPF Vaulted Ceiling No PV 1 End 14.08 ft Wood Grade #2 Rafter Sloe 220 PV 2 Start Fb 875 psi Rafter Spacing 16"O.C. PV 2 End F 135 psi To Lat Bracing Full PV 3 Start E 1400000 psi Bot Lat Bracing At Supports PV 3 End Emin 510000 psi Member Loading mary Roof Pitch 5/12 Initial Pitch Adjust Non-PV Areas PV Areas Roof Dead Load DL 8.5 sf x 1.08 9.2 psf 9.2 psf PV Dead Load PV-DL 3.0 psf x 1.08 3.2 psf Roof Live Load RLL 20.0 psf x 0.95 19.0 psf Live/Snow Load LL/SL 1,2 50.0 psf x 0.7 1 x 0.7 35.0 psf 35.0 psf Total Load TL 44.2 psf 47.4 psf Notes: 1. ps= Cs*pf,Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf= 0.7(Ce)(Ct)(Is)p9; Ce=Ct=Is=1.0; Member Design Summa (per NDS Governing Load Comb CD CL + CL - CF Cr D + S 1.15 1.00 0.38 1.1 1.15 Member Anal sis Results Summary Maximum Max Demand C.@ Location Capacity DCR Shear Stress 48 psi 1.2 ft. 155 psi 0.31 Bending W Stress 831 psi 8.1 ft. 1273 psi 0.65 Governs Bendinq - Stress -22 psi 1.2 ft. -486 psi 0.05 Total Load Deflection 0.36 in. 8.1 ft. 453 0.26 { CALCULATION OF DESIGN WIND LOADS - MP1 Mounting Plane Information Roofing Material Comp Roof PV System Type SolarCity SleekMount'" Spanning Vents No Standoff Attachment Hardware Comp Mount T e C Roof Slope 220 Rafter Spacing 16"O.C. Framing Type Direction Y-Y Rafters Purlin Spacing X-X Purlins Only NA Tile Reveal Tile Roofs Only NA Tile Attachment System Tile Roofs Only NA IStanding Seam Spacing SM Seam Only NA Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 100 mph Fig. 6-1 Exposure Category C Section 6.5.6.3 Roof Style Gable/Hip Roof Fig.6-11B/C/D-14A/B Mean Roof Height h 25 ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.95 Table 6-3 Topographic Factor Kg 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 L ortance Factor I 1.0 Table 6-1 city Pressure qh qh = 0.00256(Kz)(Kzt)(Kd)(V^2)(I)20.6 psf Equation 6-15 Wind Pressure Ext. Pressure Coefficient U GC -0.88 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient Down GC 0.45 Fig.6-11B/C/D-14A/B Design Wind Pressure p p = qh(GC ) Equation 6-22 Wind Pressure U -18.0 Psf Wind Pressure Down 10.0 Psf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 64" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 17 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T-actual -281 lbs Uplift Capacity of.Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 1 56.2% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 48" 64" Max Allowable Cantilever Portrait 17" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 21 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T-actual -352 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 1 70.3% ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING AC ALTERNATING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN POSITION, BLDG BUILDING A SIGN WILL BE PROVIDED WARNING OF THE CONIC CONCRETE HAZARDS PER ART. 690.17. DC DIRECT CURRENT 2. EACH UNGROUNDED CONDUCTOR OF THE EGC EQUIPMENT GROUNDING CONDUCTOR MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY (E) EXISTING PHASE AND SYSTEM PER ART. 210.5. EMT ELECTRICAL METALLIC TUBING 3. A NATIONALLY—RECOGNIZED TESTING FSB Fire Set—Back LABORATORY SHALL LIST ALL EQUIPMENT IN GALV GALVANIZED COMPLIANCE WITH ART. 110.3. GEC GROUNDING ELECTRODE CONDUCTOR 4. CIRCUITS OVER 250V TO GROUND SHALL GND GROUND COMPLY WITH ART. 250.97, 250.92(B) HDG HOT DIPPED GALVANIZED 5. DC CONDUCTORS EITHER DO NOT ENTER I CURRENT BUILDING OR ARE RUN IN METALLIC RACEWAYS OR Imp CURRENT AT MAX POWER ENCLOSURES TO THE FIRST ACCESSIBLE DC Isc SHORT CIRCUIT CURRENT DISCONNECTING MEANS PER ART. 690.31(E). kVA KILOVOLT AMPERE 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN kW KILOWATT RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY LBW LOAD BEARING WALL UL LISTING. MIN MINIMUM 7. MODULE FRAMES SHALL BE GROUNDED AT THE (N) NEW UL—LISTED LOCATION PROVIDED BY THE NEUT NEUTRAL MANUFACTURER USING UL LISTED GROUNDING NTS NOT TO SCALE HARDWARE. OC ON CENTER 8. MODULE FRAMES, RAIL, AND POSTS SHALL BE PL PROPERTY LINE BONDED WITH EQUIPMENT GROUND CONDUCTORS AND P01 POINT OF INTERCONNECTION GROUNDED AT THE MAIN ELECTRIC PANEL. PV PHOTOVOLTAIC 9. THE DC GROUNDING ELECTRODE CONDUCTOR SCH SCHEDULE SHALL BE SIZED ACCORDING TO ART. 250.166(B) & SS STAINLESS STEEL 690.47. STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES ' CutsheetR A LINE DIAGRAM GEN #168572 1. THIS SYSTEM IS GRID—INTERTIED VIA A ELEC 1136 MR UL—LISTED POWER—CONDITIONING INVERTER. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. 3. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED. 4. ALL WORK TO BE DONE TO THE 8TH EDITION MODULE GROUNDING METHOD: * OF THE MA STATE BUILDING CODE. 5. ALL ELECTRICAL WORK SHALL COMPLY WITH 11 25 REV BY DATE COMMENTS AHJ: North Andover THE 2014 NATIONAL ELECTRIC CODE INCLUDING REV A NAME DATE COMMENTS MASSACHUSETTS AMENDMENTS. ` 1114 UTILITY: National Grid USA (Massachusetts Electric) ` CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER JB-018728 00 PREMISE OWNER: DESCRIPTION: DESIGN: BALOGH, LAJOS P Asif Chowdhury ����• • CONTAINED SHALL NOT E USED FOR THE BALOGH RESIDENCE Y +. ,SO�a�C�t�/ BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �.��s NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 24 DARTMOUTH ST 5.865 KW PV ARRAY N m PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (23) CANADIAN SOLAR # CS6P-255PX 24 St. Martin Drive, Building 2, Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: Marlborough,REV: DATE: T: (650) 638 F: (6 A17 INVERTER: 638-1029 PERMISSION OF SOLARCITY INC. ISOLAREDGE SE6000A—US—ZB—U (617) 682-0053 COVER SHEET PV 1 7/16/2014 (888)—SOL—CITY(785-2489) www.solarcit= PITCH: 22 ARRAY PITCH:22 MP1 AZIMUTH: 145 ARRAY AZIMUTH: 145 MATERIAL: Comp Shingle STORY: 2 Stories LEGEND O (E) UTILITY METER & WARNING LABEL Inv l�� INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS °c DC DISCONNECT & WARNING LABELS - 1z AC © AC DISCONNECT & WARNING LABELS EEI A O DC JUNCTION/COMBINER BOX & LABELS DISTRIBUTION PANEL & LABELS Lc LOAD CENTER & WARNING LABELS Front Of House O DEDICATED PV SYSTEM METER � � �M��` +>� Q STANDOFF LOCATIONS * CONDUIT RUN ON EXTERIOR Q� AMIR G CONDUIT RUN ON INTERIOR MASSOLIMI GATE/FENCE 0 CIVIL Q HEAT PRODUCING VENTS ARE RED No.+ 555 i� ,i INTERIOR EQUIPMENT IS DASHED L- Dig al r fflassoumi SITE PLAN :24:1 -07�00� Scale: 3/32" = 1' 01' 10' 21' S F ARM JB-01 8728 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: ��"t ■ CONTAINED SHALL NOT BE USED FOR THE BALOGH, LAJOS P BALOGH RESIDENCE Asif Chowdhury 41.1. �arC�ty. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 24 DARTMOUTH ST 5.865 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES NORTH ANDOVER MA 01845 THE SALE AND USEEPT OF INCONNECTION RESP RESPECTIVE 23 CANADIAN SOLAR �t CS6P-255PX 24 St. Marlrlboroug MAin Drive. dO1752 Unit 11 SOLARC�lY EQUIPMENT, WITHOUT THE WRITTEN ( ) tt PAGE NAME: SHEET: REV DAIS T. (650)638-1028 F: (650)638-1029 L.PERMISSION OF SOLARCITY INC. INVERTER 617 682-0053 PV 2 7/16/201 4 (888)—SOL—CITY(765-2489) www.solarcity.com SOLAREDGE SE6000A—US—ZB—U � � SITE PLAN S1 I 13'-9" 700 1 (E) LBW SIDE VIEW OF MP1 NTS 1 rt OF$4 MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES aMirIRI LANDSCAPE 64" 24" STAGGERED MASSOU CIVIL PORTRAIT 48" 17" No.5 155 � RAFTER 2X10 @ 16" OC ROOF AZI 145 PITCH 22 STORIES: 2 ARRAY AZI 145 PITCH 22 � C.J. 2X8 @16" OC Comp Shingle + � fi PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) a(2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. ZEP COMP MOUNT C ZEP FLASHING C (3) (3) INSERT FLASHING. (E) COMP. SHINGLE (4) PLACE MOUNT. (1) (E) ROOF DECKING U (2) V INSTALL LAG BOLT WITH 5/16" DIA STAINLESS (5) (5) SEALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES F INSTALL LEVELING FOOT WITH WITH SEALING WASHER (6) BOLT & WASHERS. (2-1/2" EMBED, MIN) (E) RAFTER #_5TA NDOFF CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: JB-01.8728 00 CONTAINED SHALL NOT BE USED FOR THE BALOGH, LAJOS P BALOGH RESIDENCE Asif Chowdhury BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ����sSolar Its/' NOR MALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 24 DARTMOUTH ST 5.865 KW PV ARRAY ►,� PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES- NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St. Martin Drive, Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (23) CANADIAN SOLAR # CS6P-255PX SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV DATE: Marlborough, MA 01752 INVERTER' T. (650)638-1028 F. (650) 638-1029 PERMISSION OF SOLARCITY INC. soLAREDGE sEs000A—us—z6—u (617) 682-0053 STRUCTURAL VIEWS PV 3 7/16/2014 (B8)-sOL-CITY(765-2489) wn,.salaraitY.aam UPLIFT CALCULATIONS SEE SEPARATE PACKET FOR STRUCTURAL CALCULATIONS. NUMBER.CONFIDENTIAL— JB-01 8728 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: THE INFORMATION HEREIN JOB R CONTAINED SHALL NOT BE USED FOR THE BALOGH, LAJOS P BALOGH RESIDENCE Asif Chowdhury � �ty. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 24 DARTMOUTH ST 5.865 KW PV ARRAY ,;SOlarC� • PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES: NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION HATH 24 St. Matin Drive, Budding 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (23) CANADIAN SOLAR # CS6P-255PX PAGE NAME SHEET: REV. DATE: Marlborough, MA 01752 SOLAR�TY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T. (650)638-1028 F. (650) 638-1029 PERMI ON OF SOLARCITY INC. SOLAREDGE SE6000A—US-zB—U (617) 682-0053 UPLIFT CALCULATIONS PV 4 7/16/2014 (888)-SOL-CITY(765-2489) www.solaraity.eom GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO TWO (N) GROUND Panel Number: Inv 1: DC Ungrounded INV I -(1)SOLAREDGE ##SE6000A-US-ZB-U LABEL: A -(23)CANADIAN SOLARCS6P-255PX GEN #168572 ODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:55528841 Inverter; 6000W, 240V, 97.5%; w/Unifed Disco and ZB, AFCI PV Module; 255W#234.3W PTC, Black Frame, MC4, ZEP Enabled ELEC 1136 MR Underground Service Entrance INV 2 Voc: 37.4 Vpmax: 30.2 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 125A MAIN SERVICE PANEL E 10OA/2P MAIN CIRCUIT BREAKER SolarCity (E) WIRING SOLARGUARD Inverter 1 CUTLER-HAMMER METER 4 A 1 10OA/2P Disconnect 5 SOLAREDGE MSE6000A-US-ZB-U 1 Strings)Of 8 On(E) LOADS B .- L, z-V r---------- ------------ -------- -- ---� L2 I 1 DC+ I I 35A/2P N DG 1 3 WDC� 1 ---- GND - -- GND --- ---------------__________ _ EGC/ ___ DC+ jAfj GEC NDG DG 1 Strings)Of 15 On MP1I I� EGC--- --------- -------- ---- ---�---- -- EGC ----------------- t� I I N I (1)Conduit Kit; 3/4' EMT - _J EGCL -, z I I 1 i I 1 I - GEC-r- 1 TO 120/240V SINGLE PHASE I I UTILITY SERVICE I I I 1 I 1 I 1 I 1 I I PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Voc* = MAX VOC AT MIN TEMP POI (1)SIEMENS !Q22035CT PV ACKFEED BREAKER B (1)CUTLER-HAMMER #DG222URB �� A (1)SolarCity 4 STRING JUNCTION BOX DC Breaker, 20A/1P-35A/2P-20A�1P, 2 Spaces, Quad Disconnect; 60A, 24OVac, Non-Fusible, NEMA 3R 2x2 S1Yft GS, UNFUSED, GROUNDED -(2)Ground Rod; 5/8' x 8', Copper -(1)CUTLER-HAMMER #DC10ONB Ground eutral It; 60-100A, General Duty(DG) PV (23)SOLAREDGE #P30D-2NA4AZS C SolarGuard Monitoring System PowerBox Optimizer, 300W, H4, DC to DC, ZEP nd ( 1)AWG #6, Solid Bare Copper -(1)Ground Rod; 5/8' x 8', Copper (N) ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION NO. 2, ADDITIONAL ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE l 1 AWG #8, THWN-2, Black (1)AWG /10, THWN-2, Black Voc* =500 VDC Isc =15 ADC 2 AWG #10, PV WIRE, Black Voc* =500 VDC Isc =15 ADC O (1)AWG #8, THWN-2, Red O (1)AWG 110, THWN-2, Red Vmp =350 VDC Imp=10.79 ADC O (1)AWG #6, Solid Bare Copper ECC Vmp =350 VDC Imp=5.75 ADC (1)AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp 25 AAC (1 AWG #10, THWN-2. Green. _ EGC. . . . . . . . THWN-2, Green EGC GEC- 1 Conduit Kit; 3 4 EMT (1)AWG 10, THWN-2, Black Voc* -500 VDC Isc -15 ADC 2 AWG 10, PV WIRE, Black Voc* =500 VDC Isc =' '15' ADC . . . . . . . . . . . . . . . . . . . . . . . 4 (1)AWG 110, THWN-2, Red Vmp =350 VDC Imp=5.75 ADC O (1)AWG #6, Solid Bare Copper EGC Vmp =350 VDC Imp=10.79 ADC (1)AWG /10, 1HVYN-2,.Green. . . . .EGC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CONFlDENTIAL- THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: JB-018728 00 BALOGH, LAJOS P Asif Chowdhury CONTAINED SHALL NOT E USED FOR THE BALOGH RESIDENCE y °SolarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 24 DARTMOUTH ST 5.865 KW PV ARRAY PART IZ OTHERS C PT IN THE RECIPIENT'S MODULES: NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH � THE SALE AND USE OF THE RESPECTIVE (23) CANADIAN SOLAR # CS6P-255PX 24 St. Martin Drive, Building 2, Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PACE NAME: SHEET: REW. DATE Marlborough, MA 01752 PERMISSION OF SOLARCITY INC. INVERTER: ( ) THREE LINE DIAGRAM T. (650) 638-1028 F: (65 0) 638-1029 SOLAREDGE SE6000A-US-ZB-Ll 617 682-0053 PV 5 7 16 2014 (esa>-sa-c1TY(765-2489) www.salarcity.cam CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 24 Dartmouth St UTILITY SERVICE AC INVERTER AND DISCONNECT DC DISCONNECT I I I I � SOLAR PHOTOVOLTAIC ARRAYS) L——————————————————————————-� PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-01 8728 00 CONTAINED SHALL NOT BE USED FOR THE BALOGH, LAJOS P BALOGH RESIDENCE Asif Chowdhury ,SolarCity.BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ' NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 24 DARTMOUTH ST 5.865 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St. Martin Drive, Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (23) CANADIAN SOLAR # CS6P-255PX PAGE NAME SHEET: REV: DATE Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INT. (650)636-1028 F. (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE6000A—US—ZB—U (617) 682-0053 SITE PLAN PLACARD PV 6 7/16/2014 (886)-SOL-CITY(765-2489) www.solarcity.com SolarCity SleekMountT"" - Comp SolarCity SleekMountT"" - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM modules r ' aesthetics while minimizing roof disruption and k% 0 Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and • Interlock and grounding devices in system UL t Fastener Size Per NDS Section 1.1.3.2 mounting clamps, combined with the addition listed to UL 2703 of array trim and a lower profile all contribute • Interlock and Ground Zep ETL listed to UL 1703 0 Seal pilot hole with roofing sealant to a more visually appealing system.SleekMount as"Grounding and Bonding System" Q ,'. Insert Comp Mount flashing under upper utilizes Zep CompatibleTM modules with •Ground Zep UL and ETL listed to UL 467 as ` layer of shingle strengthened frames that attach directly to grounding device Zep Solar standoffs, effectively eliminating the ® Place Comp Mount centered I need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition .Anodized components for corrosion resistance 0 Install lag pursuant to NDS Section 11.1.3 shingles are not required to be cut for this with sealing washer. system, allowing for minimal roof disturbance. •Applicable for vent spanning functions \ © Secure Leveling Foot to the Comp Mount using machine Screw Place module ® Components _ 0 5/16"Machine Screw I! © Leveling Foot # ® -- © Lag Screw ` 0 Comp Mount © Comp Mount Flashing p 0 O i r SolarCity. p�o 0 ETA ��Solar�ity January 2013 U� LISTED �It 1/ ® January 2013 i it I dge CS6P-235/240/245/250/255PX Ne� F`a�eoesg %4r CanadianSolar Electrical Data Black-framed 8<eak`� STC CS6P-235P CS6P-240P CS6P-245P CS6P-250PXCS6P-255PX Temperature Characteristics Nominal Maximum Power (Pmax) 235W 240W 245W 25OW 255W Pmax -0.43%/°C Optimum Operating Voltage(Vmp) 29.8V 29.9V 30.OV 30.1V 30.2V , NewEdge Optimum Operating Current(Imp) 7.90A 8.03A 8.17A 8.30A 8.43A Temperature Coefficient Voc -0.34%/C Open Circuit Voltage(Voc) 36.9V 37.OV 37.1V 37.2V 37AV Isc 0.065%/°C Black-framed _ Short Circuit Current(Isc) 8.46A 8.59A 8.74A 8.87A 9.00A Normal Operating Cell Temperature 45±2°C • Module Efficiency 14.61% 14.92% 15.23% 15.54% 15.85% Operating Temperature -40"C—+85°C Performance at Low Irradiance Maximum System Voltage 1000V IEC /600V UL Industry leading performance at low irradiation Maximum Series Fuse Rating 15A environment,+95.5%module efficiency from an Application Classification ClassA irradiance of 1000w/m'to 200w/m' Power Tolerance 0-+5W (AM 1.5,25•C) Next Generation Solar Module Under Standard Test Conditions(STC)of irradiance of 1000W/m2,spectrum AM 1.5 and cell temperature of 25•C NewEdge,the next generation module designed for multiple Engineering Drawings NOCT CS6P-235P CS6P-240PX CS6P-245PX CS6P-250PX CS6P-255PX types of mounting systems,offers customers the added Nominal Maximum Power (Pmax) n0W 174W 178W 181W 185W value of minimal system costs,aesthetic seamless Optimum Operating Voltage(Vmp) 27.2V 27.3V 27AV 27.5V 27.5V appearance,auto groundingand theft resistance. Optimum Operating Current(Imp) 6.27A 6.38A 6.49A 6.60A 6.71A Open Circuit Voltage(Voc) 33.9V 34.OV 34AV 34.2V 34AV The black-framed CS6P-PX is a robust 60 cell solar module Short Circuit Current(Isc) 6.86A 6.96A 7.08A 7.19A 7.29A incorporating the groundbreaking Zep compatible frame. Under Normal operating Cell Temperature,Irradiance of 800 W/m',spectrum AM 1.5,ambient temperature 20•C, The specially designed frame allows for rail-free fast wind speed 1 m/s installation with the industry's most reliable grounding Mechanical Data system.The module uses high efficiency poly-crystalline Cell Type Poly-crystalline 156 x 156mm,2 or 3 Busbars - Key Features silicon cells laminated with a white back sheet and framed Cell Arrangement 60(6 x 10) with black anodized aluminum.The black-framed CS6P-PX Dimensions 1638 x 982 x 40mm(64.5 x 38.7 x 1.57in) • Quick and easy to install - dramatically is the perfect choice for customers who are looking for a high Weight 20.5kg(45.2 lbs) reduces installation time quality aesthetic module with lowest system cost. Front Cover 3.2mm Tempered glass Frame Material Anodized aluminium alloy • Lower system costs - can cut rooftop Best Quality .l-sox IP65,3 diodes 912 installation costs in half Cable 4mm'(IEC)/12AWG(UL),1000mm • 235 quality control points in module production Connectors MC4 or MC4 Comparable • Aesthetic seamless appearance - low profile • EL screening to eliminate product defects Standard Packaging(Modules per Pallet) 24pcs with auto leveling and alignment • Current binning to improve system performance Module Pieces per container(40 ft.Container) 672pcs(40'HQ) o • Accredited Salt mist resistant • Built-in hyper-bonded grounding system - if it's j mounted,it's grounded I-V Curves (CS6P-255PX) Best Warranty Insurance • Theft resistant hardware • 25 years worldwide coverage Section A-A i • 100%warranty term coverage • Ultra-low parts count - 3 parts for the mounting • Providing third party bankruptcy rights 35.0 and grounding system Non-cancellable I • Industry first comprehensive warranty insurance by Immediate coverage j AM Best rated leading insurance companies in the Insured by 3 world top insurance companies world — v Comprehensive Certificates 5W • Industry leading plus only power tolerance:0 • IEC 61215,IEC 61730, IEC61701 ED2,UL1703, t5 • Backward compatibility with all standard rooftop and CEC Listed,CE and MCS ground mounting systems • IS09001:2008:Quality Management System • ISO/TS16949:2009:The automotive quality •Specifications included in this dalasheet are subject to change without prior notice. • Backed By Our New 10/25 Linear Power Warranty management system Plus our added 25 year insurance coverage IS014001:2004:Standards for Environmental About Canadian Solar management system Canadian Solar Inc. is one of the world's largest solar Canadian Solar was founded in Canada in 2001 and was 70y7y A QC080000 HSPM:The Certification for companies. As a leading vertically-integrated successfully listed on NASDAQ Exchange (symbol: CSIQ) in dded Value pro Hazardous Substances Regulations manufacturer of ingots,wafers,cells,solar modules and November 2006. Canadian Solar has module manufacturing 90% m Warranty g solar systems, Canadian Solar delivers solar power capacity of 2.05GW and cell manufacturing capacity of 1.3GW. • OHSAS 18001:2007 International standards for products of uncompromising quality to worldwide 80% occupational health and safety customers. Canadian Solar's world class team of 0% professionals Compliance professionals works closely with our customers to 5 10 1s 20 25 ' p provide them with solutions for all their solar needs. HeadqUarters 1545 Speedvale Ontario • 10 year product warranty on materials and workmanshipz 0E ' ' SP ♦ cTel:+1 519 837 1881 •25 year linear power output warranty E Fax:+1 519 837 2550 www.canadiansolar.com EN-Rev 10.17 Copyright°2012 Canadian Solar Inc. PITCH: 22 ARRAY PITCH:22 MP1 AZIMUTH: 145 ARRAY AZIMUTH: 145 MATERIAL: Comp Shingle STORY: 2 Stories LEGEND Q (E) UTILITY METER & WARNING LABEL Inv lnv INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS DC DC DISCONNECT & WARNING LABELS r,- O mpl"" AC E2�3 AC DISCONNECT & WARNING LABELS A O DC JUNCTION/COMBINER BOX & LABELS 0° DISTRIBUTION PANEL & LABELS LC LOAD CENTER & WARNING LABELS Front Of House O DEDICATED PV SYSTEM METER 4� OF0 STANDOFF LOCATIONS � , CONDUIT RUN ON EXTERIOR qAMR --- CONDUIT RUN ON INTERIOR MASSOUMI + GATE/FENCE p CIVIL 0 HEAT PRODUCING VENTS ARE RED No. 555 S 1%e_` INTERIOR EQUIPMENT IS DASHED �J L= Dig al r Massoumi SITE PLAN a :24:1 07'00' Scale: 3/32" = 1' 01' 10' 21' S F CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: JB-01 8728 00 PREMISE OWNER: DESCRIPTION: DESIGN: �c`!e CONTAINED SHALL NOT BE USED FOR THE BALOGH, LAJOS P BALOGH RESIDENCE Asif Chowdhury �.,;So�arCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: wo . NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 24 DARTMOUTH ST 5.865 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES NORTH ANDOVER, MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH Ij iiiE-$ALE AND USE OF THE RESPECTIVE (23) CANADIAN SOLAR # CS6P-255PX SHEET: REV DATE Marlborough,MA 24 St. Martin Drive, Buildi01752 ng n. PAGE NAME 50) SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T. sm— 638-1028 F: (650) 638-1029 PERMISSION.OF SOLARCITY INC. SOLAREDGE SE6000A-US—ZB-U (617) 682-0053 SITE PLAN PV 2 7/16/2014 (ae8)-sa-CITY(�s5-2ass) www.sdarcity.aom 'ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING AC ALTERNATING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN POSITION, BLDG BUILDING A SIGN WILL BE PROVIDED WARNING OF THE CONIC CONCRETE HAZARDS PER ART. 690.17. DC DIRECT CURRENT 2. EACH UNGROUNDED CONDUCTOR OF THE EGC EQUIPMENT GROUNDING CONDUCTOR MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY (E) EXISTING PHASE AND SYSTEM PER ART. 210.5. EMT ELECTRICAL METALLIC TUBING 3. A NATIONALLY—RECOGNIZED TESTING FSB Fire Set—Back LABORATORY SHALL LIST ALL EQUIPMENT IN GALV GALVANIZED COMPLIANCE WITH ART. 110.3. GEC GROUNDING ELECTRODE CONDUCTOR 4. CIRCUITS OVER 250V TO GROUND SHALL GND GROUND COMPLY WITH ART. 250.97, 250.92(B) HDG HOT DIPPED GALVANIZED 5. DC CONDUCTORS EITHER DO NOT ENTER I CURRENT BUILDING OR ARE RUN IN METALLIC RACEWAYS OR Imp CURRENT AT MAX POWER ENCLOSURES TO THE FIRST ACCESSIBLE DC Isc SHORT CIRCUIT CURRENT DISCONNECTING MEANS PER ART. 690.31(E). kVA KILOVOLT AMPERE 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN kW KILOWATT RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY LBW LOAD BEARING WALL UL LISTING. MIN MINIMUM 7. MODULE FRAMES SHALL BE GROUNDED AT THE (N) NEW UL—LISTED LOCATION PROVIDED BY THE NEUT NEUTRAL MANUFACTURER USING UL LISTED GROUNDING NTS NOT TO SCALE HARDWARE. OC ON CENTER 8. MODULE FRAMES, RAIL, AND POSTS SHALL BE PL PROPERTY LINE BONDED WITH EQUIPMENT GROUND CONDUCTORS AND POI POINT OF INTERCONNECTION GROUNDED AT THE MAIN ELECTRIC PANEL. PV PHOTOVOLTAIC 9. THE DC GROUNDING ELECTRODE CONDUCTOR SCH SCHEDULE SHALL BE SIZED ACCORDING TO ART. 250.166(B) & SS STAINLESS STEEL 690.47. STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT VOLTAGE AT MAX V p VOLTAGE AT OPENP OWER cCIRCUIT VICINITY MAP INDEX W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES P THREE LINE DIAGRAM Cutsheets Attached GEN #168572 1. THIS SYSTEM IS GRID—INTERTIED VIA A ELEC 1136 MR UL—LISTED POWER—CONDITIONING INVERTER. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. 3. SOLAR MOUNTING FRAMES ARE TO BE ► GROUNDED. 4. ALL WORK TO BE DONE TO THE 8TH EDITION MODULE GROUNDING METHOD: * OF THE MA STATE BUILDING CODE. • 15. ALL ELECTRICAL WORK SHALL COMPLY WITH �'25 REV BY DATE COMMENTS AHJ: North Andover THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. r► REV A NAME DATE COMMENTS UTILITY: National Grid USA (Massachusetts Electric) � 1 '14 JB-01 8728 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED L — THE INFORMATION HEREIN JOB NUMBERBALOGH, LAJOS P BALOGH RESIDENCE Asif Chowdhury CONTAINED SHALL NOT E USED FOR THE .,,So�arCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: 24 DARTMOUTH ST 5.865 KW PV ARRAY '"' NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C PART IZ OTHERS OUTSIDE THE RECIPIENT'S MODULES: NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St. Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (23) CANADIAN SOLAR # CS6P-255PX SHEET: REV: DATE Marlborough,Drive, MA Ot�sz SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: PERMISSION OF SOLARCITY INC. 61 7 682-0053 T: (650)638-1028 R (650)638-1029 SOLAREDGE SE6000A—US—ZB—U ) COVER SHEET PV 1 7/16/2014 (888)-SOL-CITY(765-2489) www.Solorcity.c«n S1 13'-9" 1 (E) LBW SIDE VIEW OF MP1 NTS �,� OF ,, MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES43 AMIA �I LANDSCAPE 64" 24" STAGGERED CIVIL co PORTRAIT 48" 17" No. 555 RAFTER 2X10 @ 16" OC ROOF AZI 145 PITCH 22 STORIES: 2 4 ARRAY AZI 145 PITCH 22 � �G C.I. 2x8 @16" OC Comp Shingle r PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. ZEP COMP MOUNT C ZEP FLASHING C (3) (3) INSERT FLASHING. (E) COMP. SHINGLE (4) PLACE MOUNT. (1) (E) ROOF DECKING (2) V (5) INSTALL LAG BOLT WITH 5/16" DIA STAINLESS (5) SEALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES G(6)WITH SEALING WASHERINSTALL LEVELING FOOT WITH BOLT & WASHERS. (2-1/2" EMBED, MIN) (E) RAFTER STANDOFF I, CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: JB-018728 00 ��� CONTAINED SHALL NOT BE USED FOR THE BALOGH, LAJOS P BALOGH RESIDENCE Asif Chowdhury `_ BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: � solarCity. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 24 DARTMOUTH ST 5.865 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES- ' NORTH ANDOVER M A 01845 ORGANIZATION, EXCEPT IN CONNECTION WITHr THE SALE AND USE OF THE RESPECTIVE (23) CANADIAN SOLAR # CS6P-255PX 24 St. Martin Drive, Building 2, Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE: Marlborough, MA 01752 PERMISSION OF SOLARCITY INC. INVERTER: T. (650)638-1028 F: (650)636-1029 SOLAREDGE SE6000A-US-ZB-U (617) 682-0053 STRUCTURAL VIEWS PV 3 7/16/2014 (BBB)-SOL-aTY(765-2469) www.solarcity.com UPLIFT CALCULATIONS SEE SEPARATE PACKET FOR STRUCTURAL CALCULATIONS. JB-01 8728 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: CONTAINED SHALL NOT BE USED FOR THE BALOGH, LAJOS P BALOGH RESIDENCE Asif Chowdhury . SolarCity.BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 24 DARTMOUTH ST 5.865 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES NORTH ANDOVER, MA 01845 ORGTHEASALE D USEEPT OF INCONNECTION RESP RESPECTIVE (23) CANADIAN SOLAR # CS6P-255PX ' PAGE NAME: 2a St. Martin MAd01752 2. Unit 11 SHEET: REV: DATE: �FiLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER, T. (650)638-1028 F. (650) 636-1029 PERMISSIONO SOLARCITY INC. SOLAREDGE SE600OA—US—ZB—U (617) 682-0053 UPLIFT CALCULATIONS PV 4 7/16/2014 (B88)—soL-aTY(765-2469) �.solarcity.com -GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BGRD (N) #8 GEC TO TWO (N) GROUND Panel Number: Inv 1: DC Ungrounded _ 3 GEN #168572 ODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:55528841 INV 1 -(1) erter;SOLAREDGE 1/SE6240V, 97.5 B-USi (2 )CANADIAN SOLAR ," CS6P-255PX ELEC 1136 MR Inverter; 60 OW, 240V, 97.5gd w Unifed Disco and ZB, AFCI PV Module; 255 234.3W PTC, Black Frame, MC4, ZEP Enabled Underground Service Entrance INV 2 Voc: 37,4 Vpmax: 30.2 INV 3 1 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 125A MAIN SERVICE PANEL E 10OA/2P MAIN CIRCUIT BREAKER SolarCity (E) WIRING SOLARGUARD Inverter 1 CUTLER-HAMMER METER 4 A PD 100A/2P Disconnect 5 SOLAREDGE SE6000A-US-ZB-U ---- 1 String(s)Of 8 On MPI - (E) LOADS B C I __________ ________ zaov -- --- ♦- L1 r--------- L2 I I � DC+ I I / N DG 1 3 PDC+35A 2P ---- GND - -- GND --- ---------------__________ _ EGCI DC+ - -IIA GEC DG 1 String(s)Of 15 On MPI---- ----------------t� GND EGC N j (1)Conduit Kit; 3/4" EMT _J o EGC/GEC_ z I I I I I I - GEC-r_ 1 TO 120/240V 1 1 SINGLE PHASE UTILITY SERVICE I I I I I 1 i 1 I 1 PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Voc* = MAX VOC AT MIN TEMP POI (1)SIEMENS #Q22035CT PV ACKFEED BREAKER B (1)CUTLER-HAMMER #DC222URB n A (1)SdarCitY#4 STRING JUNCTION BOX D Breaker, 2OA/1P-35A/2P-20A�iP, 2 Spaces, Quad Disconnect; 60A, 24OVac, Non-Fusible, NEMA 3R A 2x2 STRMGS, UNFUSED, GROUNDED -(2)Ground Rod; 5/8' x B', Copper -(1)CUTLER-�IAMMER DG100N8 Ground/Neutral it; 60-100A, General Duty(DG) PV (3)SOLAREDGE #P300-2NA4AZS C SolarGuard Monitoring System PowerBox Optimizer, 30OW, H4, DC to DC, ZEP nd (1)AWG #6, Solid Bare Copper -( 1)Ground Rod; 5/8" x 8', Copper (N) ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION NO. 2, ADDITIONAL ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE 1 AWG #8, THWN-2, Black (1)AWG 110, THWN-2, Black Voc* =500 VDC Isc =15 ADC 2)AWG #10, PV WIRE, Black Voc* =500 VDC Isc =15 ADC O (11)AWG #8, THAM-2, Red O (1)AWG #10, THVM-2, Red Vmp =350 VDC Imp=10.79 ADC O (1)AWG#6, Solid Bare Copper EGC Vmp =350 VDC Imp=5.75 ADC (1)AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp 25 AAC (1 AWG #10, TH"-2. Green EGC . * ._ . . ._. . . . . . . . . . . . . . . -(1)AWG #8,.THWN-2,.Green . . EGC/GEC (1)Conduit_Kit;.3/4'.EMT. . , , , . . , . . (1 AWG #1U, TIiWN-2, Black . . . . . .Voc. . 500. . . . .VD. .C. Isc. 15 A. D. 0. (2)AWG #10, PV WIRE, Black Voc =500 VDC Isc =15 ADC ®91(I)AWG #10, THWN-2, Red Vmp 350 VDC Imp=5.75 ADC O (1)AWG #6, Solid Bare Copper EGC Vmp =350 VDC Imp=10.79 ADC . . . . . . (1)AWG 110, T0WN72,.Green. . . . .EGC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: JB-018728 00 BALOGH, LAJOS P BALOGH RESIDENCE Asif Chowdhury IQ CONTAINED SHALL NOT BE USED FOR THE ���� • BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: '"b- NOR alar I�y NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 24 DARTMOUTH ST 5.865 KW PV ARRAY h� PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES- NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH r THE SALE AND USE OF THE RESPECTIVE (23) CANADIAN SOLAR # CS6P-255PX 24 St Martin Drive, Building 2, Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE Marlborough, MA 01752 PERMISSION OF SOLARCITY INC. INVERTER: T. (650)638-1028 F: (650) 638-1029 SOLAREDGE SE6000A-US-ZB-U (617) 682-0053 THREE LINE DIAGRAM PV 5 7/16/2014 (BBB)-S«.-CITY(765-2489) www.sdorcitycom CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 24 Dartmouth St UTILITY SERVICE AC INVERTER AND DISCONNECT DC DISCONNECT I I I I � ------------------- — -- SOLAR PHOTOVOLTAIC AR—RAYS)—--_I L--------------------------J PHOTOVOLTAIC BACK—FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V NUMBER:CONJ B-018728 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL — THE INFORMATION HEREIN JOB CONTAINED SHALL NOT BE USED FOR THE BALOGH, LAJOS P BALOGH RESIDENCE Asif Chowdhury ';;;So�arC��ty. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: w'a� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 24 DARTMOUTH ST 5.865 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S Moou�Es NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH ' 24 St. Martin Drive, Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (23) CANADIAN SOLAR # CS6P-255PX PAGE NAME SHEET: RR. DATE: Marlborough, MA 01752 §OLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER. T. (650) 638-1028 F: (650) 638-1029 PERMISSIOILOF SOLARCITY INC. SOLAREDGE SE6000A—US-ZB-U (617) 682-0053 SITE PLAN PLACARD PV 6 7/16/2014 (888)—SOL-CITY(765-2489) www.solarcitycom Yom, SolarCity SleekMountT"" - Comp SolarCity SleekMountTM - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM modules c k aesthetics while minimizing roof disruption and 0 Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and •Interlock and grounding devices in system UL listed to UL 2703 Fastener Size Per NDS Section 1.1.3.2 mounting clamps, combined with the addition of array trim and a lower profile all contribute • Interlock and Ground Zep ETL listed to UL 1703 Q Seal pilot hole with roofing sealant to a more visually appealing system.SleekMount as"Grounding and Bonding System" O3 Insert Comp Mount flashing under upper utilizes Zep Compatible TM modules with •Ground Zep UL and ETL listed to UL 467 as layer of shingle strengthened frames that attach directly to grounding device ® Place Comp Mount centered Zep Solar standoffs, effectively eliminating the need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition .Anodized components for corrosion resistance 0 Install lag pursuant to NDS Section 11.1.3 shingles are not required to be cut for this \ with sealing washer. system, allowing for minimal roof disturbance. •Applicable for vent spanning functions © Secure Leveling Foot to the Comp Mount using machine Screw Q7 Place module O Components © (Z) 5/16"Machine Screw T © Leveling Foot 111 t ~I © Lag Screw QD Comp Mount © 0 Comp Mount Flashing O iiv�SolarCity January 2013 ��%m 0% U< LISTED SolarCity. January 2013 DMPP 9� CS6P-235/240/245/250/255PX Ne��dgeoes,� ®4P CanadianSolarElecBlack-framed eleak�hloaB trical Data STC CS6P-235P CS6P-240PX CS6P-245PX CS6P.250PX CS6P-255PXI Temperature Characteristics Nominal Maximum Power (Pmax) 235W 240W 245W 25OW 255W Optimum Operating Voltage(Vmp) 29.8V 29.9V 30.OV 30.1V 30.2V Pmax -0.43%/'C NewEdge Temperature Coefficient Voc -0.34%rC Optimum Operating Current(Imp) 7.90A 8.03A 8.17A 8.30A 8.43A P Open Circuit Voltage(Voc) 36.9V 37.OV 37AV 37.2V 37AV Isc 0.065%/`C Black-framed Short Circuit Current(Isc) 8.46A 8.59A 8.74A 8.87A 9.00A Normal Operating Cell Temperature 4532°C Module Efficiency 14.61% 14.92% 15.23% 15.54% 15.85% Operating Temperature -40•C-+850C Performance at Low Irradiance ' Maximum System Voltage 1000V IEC /600V UL Industry leading performance at low irradiation Maximum Series Fuse Rating 15A environment,+95.5%module efficiency from an Application Classification Class A irradiance of 1000w/m'to 200w/m' Power Tolerance 0-+5W (AM 1.5,25°C) Next Generation Solar Module Under Standard Test Conditions(STC)of Irradiance of 1000W/m',spectrum AM 1.5and cell temperature of 25'C NewEdge,the next generation module designed for multiple Engineering Drawings NOCT CS6P-235PX CS6P-240PX CS6P-245PX CS6P-250PX CS6P-255PX types of mounting systems,offers customers the added Nominal Maximum Power(Pmax) 170W 174W 178w 181w 185W value of minimal system costs,aesthetic seamless 27.2V 27.3V 27AV 27.5V 27.5V y Optimum Operating Voltage(Vmp) appearance,auto groundingand theft resistance. Optimum Operating Current(Imp) 6.27A 6.38A 6.49A 6.60A 6.71A _ Open Circuit Voltage(Voc) 33.9V 34.OV 34.1V 34.2V 34.4V 1 The black-framed CS6P-PX is a robust 60 cell solar module Short Circuit Current(Ise) 6.86A 6.96A 7.08A 7.19A 7.29A Incorporating the groundbreaking Zep Compatible frame. Under Normal Operating Cell Temperature,Irradiance of 800 W/m',spectrum AM 1.5,ambient temperature 20'C, The specially designed frame allows for rail-free fast wind speed 1 m/s installation with the industry's most reliable grounding Mechanical Data system.The module uses high efficiency poly-crystalline Cell Type Poly-crystalline 156 x 156mm,2 or 3 Busbars Ke Features silicon cells laminated with a white back sheet and framed Cell Arrangement 60(6 x 10) Key with black anodized aluminum.The black-framed CS6P-PX Dimensions 1638 x 982 x 40mm(64.5 x 38.7 x 1.57in) • Quick and easy to install - dramatically is the perfect choice for customers who are looking for a high Weight 20.5kg(45.2 lbs) reduces installation time quality aesthetic module with lowest system cost. Front cover 3 Tempered glass Frame Material Anodized aluminium alloy • Lower system costs - can cut rooftop Best Quality ,1-130x IP65,3diodes 42 installation costs in half Cable 4mm'(IEC)/12AWG(UL),1000m 235 quality control points in module production Connectors MC4 or MC4 Comparable • Aesthetic seamless appearance - low profile • EL screening to eliminate product defects Standard Packaging(Modules per Pallet) 24pcs with auto leveling and alignment • Current binning to improve system performance Module Pieces per container(40 ft.Container) 672pcs(40'HQ) • Accredited Salt mist resistant • Built-in hyper-bonded grounding system - if it's I-V Curves (CS6P-255PX) mounted,it's grounded Best Warranty Insurance _ I • Theft resistant hardware • 25 years worldwide coverage • 100%warranty term coverage sectionA-A — --------- -- — • Ultra-low parts count - 3 parts for the mounting • Providing third party bankruptcy rights 35.0 I and grounding system • Non-cancellable i I • Industry first comprehensive warranty insurance by Immediate coverage ' AM Best rated leading insurance companies in the Insured by 3 world top insurance companies 1 v I world — " — Comprehensive Certificates • Industry leading plus only power tolerance:05W IEC 61215,IEC 61730, IEC61701 ED2,UL1703, i5 • Backward compatibility with all standard rooftop and CEC Listed,CE and MCS •- ground mounting systems • IS09001:2008:Quality Management System specifications included in this datasheet are subject to change without prior notice. ISO/TS 16949:2009:The automotive quality • Backed By Our New 10/25 Linear Power Warranty management system Plus our added 25 year insurance coverage • IS014001:2004:Standards for Environmental About Canadian Solar management system Canadian Solar Inc. is one of the world's largest solar Canadian Solar was founded in Canada in 2001 and was 1007 A • QC080000 HSPM:The Certification for companies. As a leading vertically-integrated successfully listed on NASDAQ Exchange (symbol: CSIQ) in 90/ Added Value From Warr Hazardous Substances Regulations manufacturer of ingots,wafers,cells,solar modules and November 2006. Canadian Solar has module manufacturing m anty solar systems, Canadian Solar delivers solar power capacity of 2.05GW and cell manufacturing capacity of 1.3GW. • OHSAS 18001:2007 International standards for products of uncompromising quality to worldwide 80% occupational health and safety customers. Canadian Solar's world class team of o% REACH Compliance professionals works closely with our customers to s 10 is 20 zs P provide them with solutions for all their solar needs. Ontario N 1 K 1 E6 I Canada • 10 year product warranty on materials and workmanship s aE i` $p• N �`.SERT "Fax:+1 519 837 r •25 year linear power output warranty www.canadiansolar.com •• EN-Rev 10.17 Copyright 0 2012 Canadian Solar Inc. • solar " ® • = solar ' e • T SolarEdge Power Optimizer Module Add-On for North America P300 / P350 / P400 SolarEdge Power Optimizer 6 P350 P400 Module Add-On For North America (for 60-cell PV (for 72-cell PV (for 96-cell PV modules) modules) modules) INPUT P300 / P350 / P400 • - RatedlnputDC Power'1) 300 350 400 W I ...... .......... V ( Absolute Maximum Input Voltage(Voc at lowest temperature) 48 6.. I 80 do . MPPT Operating Range.........................................................$-48.....................a.:60....................$.:$.......... ....Vdc..... • Maximum Short Circuit Current(Isc) 30 Adc Maximum DC In ut Current 12.5 Adc ..............................................,.................................................................................................................. ............. Maximum Efficien 99.5 % i .Weighted Efficiencl'..................................................... ................ 98.8 % ................................................................................ Overvoltage Category L11 OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) — Maximum Output Current 15 Adc Maximum Output Voltage 60 Vdc • OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE _ in4f_� ----------. ------------ -- ------ -- !I�"" EMC FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3 .............................................................................. ................................................................................................ RoHS - ...................IEC62109-1(cla Yes l safetUL1741 �.� _!N STALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc ................................................................................................................................................................. ............. Dimensions(WxLx H) 141x212 x40.5/5.55 x8.34x1.59 mm/in .............................................................................................................................................................................. Weight(including cables) 950/2.1 gr/Ib ................................................................................................................................................................. ............. Input Connector MC4/Amphenol/Tyco ................................................................................................................................................................. ............. Output Wire Type/Connector Double Insulated;Amphenol Output Wire Length.................................................... ....... :95.1.3: ........_....................1.2/.3:9....................... ...m/.ft.... Operating Temperature Range ' ................................Range.. ........................ ..... ................................................................................................ - Protection Rating IP6S/N.EMA4 .............................................................................................................................................................................. Relative Humidity 0-100 % .............................................................................................................................................................................. ISIRatedsT-f-Ie.Motlule of up to+s%power tokrance albwed. PV SYSTEM DESIGN USING A SOLAREDGE SINGLE PHASE THREE PHASE THREE PHASE II, INVERTER 208V 480V PV power optimization at the module-level Minimum String Length(Power Optimizers) B 10 18 .............................................................................. ...................................................... ........................ Up to 25%more energy Maximum String Length(Power Optimizers) 25 25 50 ................................... — Superior efficiency(99.5%) Maximum Power per String 5250 6000 12750 W Parallel Strings of Different Lengths or Orientations Yes — Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading ""."""" ."""' """"""'""""" ' — Flexible system design for maximum space utilization — Fast installation with a single bolt - Next generation maintenance with module-level monitoring — Module-level voltage shutdown for installer and firefighter safety USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us CE OK ED so I =@9 SoIar ' • • . Single Phase Inverters for North America SoIar SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ SE7600A-US/SE10000A-US/SE11400A-U S-3000A-US SE3800A-US SESOOOA-US SE6000A-US SE7600A-US SE10000A-US SE11400A US OUTPUT SolarEdge Single Phase Inverters . 9980@208V Nominal AC Power Output 3000 3800 5000 6000 7600 11400 VA 10000 @240V. ................. ......... 5400 @ 208V 10800 @ 208V Max.AC Power Output 3300 4150 6000 8350 12000 VA For North America ...... .5450@240... ................ ................ .10950.@�4�V. .................. ........... ..................................... ................ ......... AC Out Voltage Min:No Max.' / / 183-208-229 Vac ......... ............................. ................ ............... ................. ................ ................ .................. .................. ........... SE3000A-US SE380OA-US/SE5000A-US/SE6000A-US AC Output Voltage Min:Nom.-Max.' � � � � � � � SE760OA-US/SE1000OA-US/SE1140OA-US 211-240-264 Vac ......-240-264........................ ................ ............... ........ ....... ................ ................ .................. .................. ........... AC Frequency Min_Nom..Max.' 59.3-60--.6. (with HI country setting 57.60.60:5) Hz 21 @ 208V 48 @ 208V Max.Continuous Output Current . 12.5 I 16 - �. .- @ 240V..) ,,,25 ,•I,,,, 32 42 @ 240V 47.5 A .................. ......... GFDI I Utility Monitoring,Islanding Protection,Country Configurable Yes '�werte,``< Thresholds INPUT 0 12 25 ' Recommended Max.DC Power** .feats 3750 4750 6250 7500 9500 12400 14250 W WaRanbl (STC) ......... �aVdc J`• Transformer-less Un rounded Yes »a .• nput Voltage Max.I.................................. ..........................................................500........................................................... ... .... Nom.DC Input Voltage 325 @ 208V/350 @ 240VVdc ............ Max.Input Current' ... .-•...95.-.•• I. ..13......1..15.5.@,240V-� .. .... . 23 ..3035@2240V .. . Adc Max.Input ShortCircuitCurrent .,,,.-30 „ 45 ,Adc ..... ............. ................ .I........... ................ .. ... Reverse:Polarity Protection ..........................................................Yes........................................................... -i Ground-Fault Isolation Detection 6001,o Sensitivity .i ..MaximuminverterEfficiency,,,_•_... .....97.7.... 98.2 .....98.3..... ....98:3...... ... 98 ......98...... ......98...... ..%..... ......imug..........E ci ... .7....... ............. ... .. .. 97.5 @ 208V 97 @ 208V CEC Weighted Efficient 97.5 98 97.5 97.5 97.5 ............... 98 @ 240V.. ............... ..97,5 @ 240V., Nighttime Power Consumption <2.5 <4 W ADDITIONAL FEATURES + Supported Communication Interfaces RS485,RS232,Ethernet,ZigB.ee(optional) •'�!!� -""�- Revenue Grade Data ANSI C12.1 Optional STANDARD COMPLIANCE UL1741,UL16998,UL1998,CSA 22.2 Grid Connection Standards IE...EE1...547 .........................................I............ ........... . ....................................... ........................................................ . ... . Emissions FCC part15 class B INSTALLATION SPECIFICATIONS + AC output conduit size/AWG range 3/4"minimum/24-6 AWG 3/4"minimum/8-3 AWG ...P...........................g.... ............... ......................................... ...................................................... ........... DC input conduit size/#of strings/ 3/4"minimum/1-2 strings/24-6 AWG 3/4"minimum/1-2 strings/14-6 AWG AWG range............................ . Dimensions with AC/DC Safety 30.5 x 12.5 x 7/ 30.5 x 12.5 x 7.5/ 30.5 x 12.5 x 10.5/775 x 315 x 260 in/ !I .Switch(HxWxD)....................... ........775 x 315 x 172....... ........775 x 315 x 191........ ...................................................... ...mn!.... Weight with AC/DC Safety Switch..... ..........51:2./23:?.......... ...........54:7/.24:?........... .....................8.8....4../..4.0....1..................... .lb/.kg... ....... Cooling NaturaIConvection Fans(userreplaceable) .......................................... ................................. ........... ........... Noise <.25 <50 dBA . The best choice for SolarEdge enabled systems Min.-Max.operating Temperature -13 to+140/-25to+60(CAN version****-40to+60) •F/•C - Integrated arc fault protection(Type 1)for NEC 2011690.11 compliance Range Protection Rating NEMA 3R Superior efficiency(98%) For other regional settings please contact SolarEdge support. Small,lightweight and ens to install on provided bracket Limited to 125%for locations where the yearly avenge high temperature is above 77-F/25•C and to 135%for locations where it is below 77'F/25•C. y p For detailed information,refer to httn-/1www.solared /fil /odf/'n rt r d o rsli na a'd odf Built-in module level monitoring *''A higher current source maybe used;the inverter will limit its input current to the values stated. g "'CAN P/Ns are eligible for the Ontario FIT and micmFlT(micmFIT exc.SE11400A-US-CAN). - Internet connection through Ethernet or Wireless - Outdoor and indoor installation - Fixed voltage inverter,DC/AC conversion only - Pre-assembled AC/DC Safety Switch for faster installation - Optional-revenue grade data,ANSI C12.1 s.nsl?EcRoHS USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-ISRAEL www.solaredge.us 0 SolarEdge Tec-1riologies.Inc.All rights reserved.SOLAREDGE.the SolarEdge lcg�.OPTIMIZED BY SOLARIEDGE are trajemarks or regsterecl tfademarks of SolarEdge Technologies.In..All G�heltradema,ks mewicrea herein• ti Date . .... .. HOR7M o� TOWN OF NORTH ANDOVER t - PERMIT FOR GAS INSTALLATION • °� _ a ,SSAC'HUSEt t' This certifies that J-k,'). . .Nn^C!'"/ . . . . .j. . . . . . .has permission for gas inst lation . f— +� . U�. . .!!�`!� in the buildings of . .�., Q. d . . ... . . . . . . . . . . . . . . . . . . .N^. -. . . . . . .. No A over ass. Fee— . . Lic. No.�(. . . . . H . . . ` •�O GAS INSPECTOR Check# 1t 8214 9CA I &D� MASSACHUSETTS UNIFORM APPLICATION FOR A PERMIT TO PERFORM GAS FITTING WORK CITY NORTH ANDOVER MA DATE JUNE 21,2012 PERMIT# Dy1 JOBSITE ADDRESS 24 DARTMOUTH ST. OWNER'S NAME I JEFFCO INC. GOWNER ADDRESS I JEFFCO INC, I TEq 978-886-8408 FAX TYPE OR OCCUPANCY TYPE COMMERCIAL EDUCATIONAL® RESIDENTIALM PRINT CLEARLY NEW:E] RENOVATION:E] REPLACEMENT:F-1 PLANS SUBMITTED: YES® NO® APPLIANCES Z FLOORS- BSM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 BOILER BOOSTER CONVERSION BURNER COOK STOVE _ - DIRECT VENT HEATER DRYER FIREPLACE FRYOLATOR FURNACE GENERATOR GRILLE INFRARED HEATER LABORATORY COCKS MAKEUP AIR UNIT OVEN POOL HEATER ROOM/SPACE HEATER ROOF TOP UNIT TEST J UNIT HEATER _ UNVENTED ROOM HEATER WATER HEATER OTHER I RUN AN UNDERGROUND GAS 1 LINE TO A PLUMBERS INSPECTED LINE i INSURANCE COVERAGE have a current liability insurance policy or its substantial equivalent which meets the requirements of MGL.Ch.142 YES E]NO I IF YOU CHECKED YES,PLEASE INDICATE THE TYPE OF COVERAGE BY CHECKING THE APPROPRIATE BOX BELOW LIABILITY INSURANCE POLICY M OTHER TYPE INDEMNITY M BOND F1 OWNER'S INSURANCE WAIVER:I am aware that the licensee does not have the insurance coverage required by Chapter 142 of the Massachusetts General Laws,and that my signature on this permit application waives this requirement. CHECK ONE ONLY: OWNY ® AGE SIGNATURE OF OWNER OR AGENT I hereby certify that all of the details and information I have submitted or entered regarding this application aue n ccurat the of my wledge and that all plumbing work and installations performed under the permit issued for this application will be in comp a wit e ' provi ' of the Massachusetts State Plumbing Code and Chapter 142 of the General Laws. PLUM BER-GASFITTER NAME JOHN COOMBSLICE NSE 064 SIGNATURE -- - - MP® MGF EJ JP® JGF LPGI[D CORPORATION EI# ARTNERSHIP®# — LLC®# COMPANY NAME: EASTERN PROPANE GAS ADDRESS 131 WATER ST. CITY DANVERS STATE MA ZIP 01923 TEL800-322-6628 FAX CELL EMAIL t PrintF:orm ` The Commonwealth of Massachusetts Department of Industrial Accidents :O'�'� Office of Investigations L= 1 Congress Street, Suite 100 Boston, NLA 02114-2017 www.mass.gov/dia WorkersCompensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant I-afa-rMM is 0,1a - -Tease Print-Le6ibINT Name (Business/O /ln rganizationdividual): EASTERN PROPANE&OIL Address: 131 WATER STREET Ciry/State/Zip: DANVERS, MA 01923 Phone #- 978-750-6500 Are you an employer? Check the appropriate boa: Type of project (required): 45 4. ❑ I am a general contractor and I 1.7' I am a employer with 6 ❑New construction employees (full and/or part-time).* have hired the sub-contractors 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. El Remodeling ship and have no employees These sub-contractors have g. ❑ Demolition employees and have workers' working for me in any capacity. 9. ❑ Building addition [No workers' comp. insurance comp. insurance.+ 5. ❑ We are a corporation and its 10.[] Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.❑ Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs insurance required.] T c. 152, �l(4), and we have no GAS FITTING employees. [No workers' 1 Other comp. insurance required.] *Any applicant that checks box"1 muni also fill out the section below showing their workers' compensation policy information. T Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. *Contractors that check ties box must attached an additional sheet showing the name of the sub-contractors and state whether or not(nose entities have employees. If the sub-contractors have employee's;they must provide their workers' comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: LIBERTY MUTUAL INSURANCE COMPANY Policy or Self-ins. Lic. WC7-641-435806-052 Expiration Date: 03115 / 2013 Job Site Address: d q ` QV+ M6.r,. Sfi • City/State/Zip:tl\yr`lJ, Attach a copy of the workers' compensation policy declaration page (showing the policy number and expiration date �4S Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to S1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. T do hereby certif>) under the pains and penalties operjury that the information provided above is true and correct Signature I 7DateJi 03/13/2013 Phone : 978-750-6500 Official use only. Do not write in this area; to be completed by city or town officiaL City or Town: Permit/License r Issuina Authori _- - ,.b t}' (circle 1. Board of Health 2. Biu-ilding Inspector S. Plumbing Inspector 6. Other Contact Person: Phone;: