Loading...
HomeMy WebLinkAboutBuilding Permit #055-2017 - 254 GREAT POND ROAD 7/18/2016 (3) NORTH BUILDING PERMIT 0 tt-06gry TOWN OF NORTH ANDOVER ab o o APPLICATION FOR PLAN EXAMINATION � off ; ,• Permit No#• Date Received �RA�RATEo �SSACHUSES Date Issued: l6 IMPORTANT: Applicant must complete all items on this page LOCATION PoAd Vilyl- - Print ,✓ PROPERTY OWNER ���vt �) (,�Ip Print100 Year Structure yes no MAP PARCEL:_ZONING DISTRICT: Historic District yes no Machine Shop Village yes no TYPE OF IMPROVEMENT PROPOSED USE Residential Non- Residential ❑ New Building XOne family ❑Addition ❑Two or more family ❑ Industrial ❑Alteration No. of units: ❑ Commercial Repair, replacement ❑ Assessory Bldg ❑ Others: Demolition ❑ Other ❑ Septic ❑Well ❑ Floodplain ❑Wetlands ❑ Watershed District 0 Water/Sewer �e,,✓DESCRIPTION OF WORK TO BE PERFORMED: Identification-.Please T pe or Print Clearly OWNER: Name: ,' d1�r �/ � Phone: Address: Contractor Name:�� ZtJal)UI��� Phone: Email: Address: � 7 Supervisor's Construction License:� Q � Exp. Date: Home Improvement License_ r Exp. Date: ��! ARCHITECT/ENGINEER ( i6t,,,_ ti� /-�6J _ Phone: Address: al -y- 4q: V-' Reg. No. FEE SCHEDULE.BOLDING PERMIT:$12.00 PER$1000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PER S.F. Total Project Cost: $� ado , FEE: $ 4 Check No.: z fZ Receipt No.: 3 NOTE: Persons contracting with unregistered contractors do not have access to the guaranty fund Plans Submitted ❑ Plans Waived ❑ Certified Plot PlanStamped Plans TYPE OF SEWERAGE DISPOSAL Public Sewer Tanning/Massage/Body Art ❑ Swi nming Pools ❑ well ❑ Tobacco Sales ❑ Food Packaging/Sales ❑ Private(septic tank,etc. ❑ permanent Dumpster on Site ❑ THE FOLLOWING SECTIONS FOR OFFICE USE ONLY INTERDEPARTMENTAL SIGN OFF m U FORM PLANNING & DEVELOPMENT Reviewed On ��� �� Signature_ J COMMENTS PE-a- U3SP ` 1 i c(11� 1 �,5�lo�-s- �-nc�1l '( ��.C�e h'IQMt� -71 K- jI � f ryy r a4-i-V41,v d -770A Wtl( ea l y 7-z �o e x4 ✓e7-rD it P-t p Le-ad /j// Ce mew nan;�S IA( .Qr-_ Pe-rtA<< y kr q 6 MU, t4e7? t /m5ub. C,hc� cz. r ago -7I`S1 i tm CONSERVATION Reviewed on Signature COMMENTS HEALTH Revie e o Signature COMMENTS Zoning Board of Appeals:Variance, Petition No: Zoning Decisionlreceipt submitted yes Planning Board Decision: Comments z Conservation Decision: Comments :3 Water& Sewer ConnectionlSiglnature& Date Driveway Permit DPW Town Engineer: Signature: Located 384 Osgood Street FIREtDEPARTMENT - Tem Du _. a; p rnpster onsite• Located at�1a24iMam�Street ° • `" _F -� Fire�De,p rpq si /date _ ,gnature 7n�� j� COMMENTS- � NORT1� n over Town of No. h * ver Mass Z(3 � 0'P�reo U BOARD OF HEALTH Food/Kitchen PERMIT T LD Septic System THIS CERTIFIES THAT .../49!Ite1R... .... ... ...... ..�. .,�, BUILDING INSPECTOR ............. ................ Foundation has permission to erect .......................... buildings on . ........ ... .. .. .. . Rough to be occupied a ::TA ., ,.. .. ... ....2.. Chimney provided that the person accept g this permit shall in every espect conform to the termg of the application Final on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection, Alteration and Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR VIOLATION of the Zoning or Building Regulations Voids this Permit. Rough Final PERMIT EXPIRES IN 6 MONTHS ELECTRICAL INSPECTOR UNLESS CONSTRU TION Rough Service ... .. . . . . ... ... .... Fina BUILDING IN TO...... GAS INSPECTOR Occupancy Permit Required to Occupy Building Rough Display in a Conspicuous Place on the Premises — Do Not Remove Final No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. Burner Street No. Smoke Det. ®Boise Cascade Triple 1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP Floor Beam\1331-A Dry 2 spans No cantilevers 10/12 slope June 30, 2016 16:13:19 BC CALCO Design Report Build 4516 File Name: 15325 Garage2 Job Name: 15-325 254 GREAT POND Description: Designs\B31-A Address: 254 GREAT POND Specifier: City, State, Zip: NORTH ANDOVER, MA Designer: Customer: Company: GELINAS STRUCTURAL ENGINEERING LLC Code reports: ESR-1040 Misc: 2 3E V 12-00-00 12-00-00 BO B1 B2 Total of Horizontal Design Spans=24-00-00 Reaction Summary(Down/ Uplift) (lbs) Bearing Live Dead Snow Wind Roof Live BO 210/30 351 /0 975/0 B1 600/0 1,171 /0 3,000/0 B2 210/30 351 /0 975/0 Live Dead Snow Wind Roof Live Trib. Load Summary Tag Description Load Type Ref. Start End 100% 90% 115% 160% 125% 1 Standard Load Unf.Area (Ib/ft^2) L 00-00-00 24-00-00 20 10 02-00-00 2 ROOF Unf.Area (Ib/ft"2) L 00-00-00 24-00-00 10 50 04-00-00 Controls Summary Value %Allowable Duration Case Location Pos. Moment 3,163 ft-lbs 8.6% 115% 4 04-08-14 Neg. Moment -5,005 ft-lbs 13.6% 115% 6 12-00-00 Neg. Moment -5,005 ft-lbs 13.6% 115% 6 12-00-00 End Shear 1,031 lbs 7.6% 115% 4 01-00-12 Cont. Shear 1,770 lbs 13% 115% 6 13-01-10 Total Load Defl. L/999 (0.046") n/a n/a 4 05-04-03 Live Load Defl. L/999 (0.035") n/a n/a 20 18-06-14 Total Neg. Defl. L/999 (-0.003") n/a n/a 12 10-08-08 Max Defl. 0.046" n/a n/a 4 05-04-03 Span/Depth 12.1 n/a n/a 0 00-00-00 Notes Entered/Displayed Horizontal Span Lehgth(s)= Clear Span + 1/2 min. end bearing + 1> . 1/2 intermediate bearing Design meets Code minimum (L/240)Total load deflection criteria. Y qki Design meets Code minimum (L/360) Live load deflection criteria. '• ,;rah C ? Minimum bearing length for BO is 1-1/2". L n,. Minimum bearing length for B1 is 1-1/2". ® Minimum bearing length for B2 is 1-1/2". a ST'"` A, Calculations assume Member is Fully Braced. ao >3j34 Design based on Dry Service Condition. Deflections less than 1/8"were ignored in the results. Fastener Manufacturer:TrussLok (tm) - 1 ; Page 1 of 2 ®Boise Cascade Triple 1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP Floor Beam11331-A Dry 2 spans No cantilevers 10/12 slope June 30, 2016 16:13:19 BC CALCO Design Report - Build 4516 File Name: 15325 Garage2 Job Name: 15-325 254 GREAT POND Description: Designs\B31-A Address: 254 GREAT POND Specifier: City, State, Zip: NORTH ANDOVER, MA Designer: Customer: Company: GELINAS STRUCTURAL ENGINEERING LLC Code reports: ESR-1040 Misc: Connection Diagram Disclosure �►I b d Completeness and accuracy of input must L be verified by anyone who would rely on a output as evidence of suitability for • • • particular application.Output here based C on building desi ed • • • pr pertie and a alys stme hods• Installation of Boise Cascade engineered wood products must be in accordance with e current Installation Guide and applicable building codes.To obtain Installation Guide or ask questions,please call a minimum =2" c=7-7/8" (800)232-0788 before installation. b minimum =4" d =24" e minimum = 1" BC CALCO,BC FRAMER@,AJSTM" ALLJOISTO,BC RIM BOARD M,BCI@), All TrussLok screws may be installed from one side of multiple ply VERSA-LAM beams. BOISE GLULAMT" SIMPLE FRAMING All TrussLok screws may be installed from one side of multiply Versa-Lam beams. SYSTEM@,VERSA-LAM@,VERSA-RIM PLUS@,VERSA-RIM@, Member has no side loads. VERSA-STRAND@,VERSA-STUD@ are Connectors are: FMTSL005 trademarks of Boise Cascade Wood Products L.L.C. ®Boise Cascade Quadruple 1-3/4" x 24" VERSA-LAM® 2.0 3100 SP Floor Beam11331-13 Dry 1 span No cantilevers 10/12 slope June 30, 2016 16:09:49 BC CALC®Design Report Build 4516 File Name: 15325 Garage2 Job Name: 15-325 254 GREAT POND Description: Designs\B31-B Address: 254 GREAT POND Specifier: City, State, Zip: NORTH ANDOVER, MA Designer: Customer: Company: GELINAS STRUCTURAL ENGINEERING LLC Code reports: ESR-1040 Misc: 4 6 5 3 2 29-00-00 BO 61 Total of Horizontal Design Spans=29-00-00 Reaction Summary (Down /Uplift) (Ibs) Bearing Live Dead Snow Wind Roof Live BO 5,466/0 5,023/0 6,223/0 B1 4,914/0 4,170/0 4,714/0 Live Dead Snow Wind Roof Live Trib. Load Summary Tag Description Load Type Ref. Start End 100% 90% 115% 160% 125% 1 FLOOR Unf.Area (Ib/ft^2) L 00-00-00 29-00-00 40 10 05-06-00 2 CEILING LOW Unf.Area (Ib/ft^2) L 00-00-00 25-00-00 20 10 02-06-00 3 ROOF HIGH Unf.Area (Ib/ft^2) L 00-00-00 25-00-00 10 50 05-09-00 4 WALL Unf. Lin. (Ib/ft) L 00-00-00 25-00-00 0 80 n/a 5 CEILING HIGH Unf.Area (Ib/ft"2) L 00-00-00 25-00-00 20 10 05-06-00 6 ROOF LOW Unf.Area (Ib/ft"2) L 00-00-00 25-00-00 10 50 03-00-00 Controls Summary Value %Allowable Duration Case Location Pos. Moment 98,605 ft-lbs 53.3% 115% 3 14-03-01 End Shear 11,791 lbs 32.1% 115% 3 02-00-14 Total Load Defl. L/378 (0.92") 63.5% n/a 3 14-07-05 Live Load Defl. L/595 (0.585") 60.5% n/a 6 14-07-05 Max Defl. 0.92" n/a n/a 3 14-07-05 Span/Depth 14.5 n/a n/a 0 00-00-00 Notes Entered/Displayed Horizontal Span Length(s)= Clear Span + 1/2 min. end bearing + "" : ,, '44 . 1/2 intermediate bearing .� ai '0 � 1 <-t Design meets Code minimum (L/240)Total load deflection criteria. Design meets Code minimum (L/360) Live load deflection criteria.; morin; F- Minimum bearing length for BO is 2-5/8". Minimum bearing length for B1 is 2-3/16". Calculations assume Member is Fully Braced. Design based on Dry Service Condition. Deflections less than 1/8 were ignored in the results. Fastener Manufacturer.TrussLok (tm) `It •-.wt Page 1 of 2 ®Boise Cascade Quadruple 1-3/4" x 24" VERSA-LAM® 2.0 3100 SP Floor Beam11331-13 Dry 1 span No cantilevers 10/12 slope June 30, 2016 16:09:49 BC CALC®Design Report Build 4516 File Name: 15325 Garage2 Job Name: 15-325 254 GREAT POND Description: Designs\B31-B Address: 254 GREAT POND Specifier: City, State, Zip: NORTH ANDOVER, MA Designer: Customer: Company: GELINAS STRUCTURAL ENGINEERING LLC Code reports: ESR-1040 Misc: Connection Diagram Disclosure �►{ b d Completeness and accuracy of input must a be verified by anyone who would rely on a . . output as evidence of suitability for C particular application.Output here based on building code-accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with e current Installation Guide and applicable building codes.To obtain Installation Guide or ask questions,please call a minimum=2" C= 10" (800)232-0788 before installation. b minimum =4" d =24" e minimum — 1" BC CALC®,BC FRAMER®,AJSTM, ALLJOIST®,BC RIM BOARD-,BCI®, BOISE GLULAMT"^ SIMPLE FRAMING Calculated Side Load = 350.0 Ib/ft SYSTEM®,VERSA-LAM®,VERSA-RIM PLUS®,VERSA-RIM®, Beams 7 inches wide will be assumed to be either top-loaded only, or equally loaded from VERSA-STRAND®,VERSA-STUD®are each side. trademarks of Boise Cascade Wood All TrussLok screws may be installed from one side of multiple ply VERSA-LAM beams. Products L.L.C. All TrussLok screws may be installed from one side of multiply Versa-Lam beams. Connectors are: FMTSL634 ®Boise Cascade Quadruple 1-3/4" x 20" VERSA-LAM® 2.0 3100 SP Floor Beam11331-C Dry 1 span No cantilevers 10/12 slope June 30, 2016 16:13:20 BC CALC®Design Report Build 4516 File Name: 15325 Garage2 Job Name: 15-325 254 GREAT POND Description: Designs\B31-C Address: 254 GREAT POND Specifier: City, State, Zip: NORTH ANDOVER, MA Designer: Customer: Company: GELINAS STRUCTURAL ENGINEERING LLC Code reports: ESR-1040 Misc: i 25-00-00 BO 131 Total of Horizontal Design Spans=25-00-00 Reaction Summary (Down/ Uplift) (lbs) Bearing Live Dead Snow Wind Roof Live BO 5,250/0 1,819/0 B1 5,250/0 1,819/0 Live Dead Snow Wind Roof Live Trib. Load Summary Tag Description Load Type Ref. Start End 100% 90% 115% 160% 125% 1 Standard Load Unf. Area (Ib/ft^2) L 00-00-00 25-00-00 40 10 10-06-00 Controls Summary Value %,Allowable Duration Case Location Pos. Moment 44,183 ft-lbs 38.8% 100% 1 12-06-00 End Shear 6,085 lbs 22.9% 100% 1 01-08-14 Total Load Defl. L/563 (0.533") 42.6% n/a 1 12-06-00 Live Load Defl. L/759 (0.396") 47.5% n/a 2 12-06-00 Max Defl. 0.533" n/a n/a 1 12-06-00 Span/Depth 15 n/a n/a 0 00-00-00 Notes Entered/Displayed Horizontal Span Length(s)=Clear Span + 1/2 min. end bearing + 1/2 intermediate bearing Design meets Code minimum (L/240)Total load deflection criteria. Design meets Code minimum (L/360) Live load deflection criteria. Minimum bearing length for BO is 1-1/2". Minimum bearing length for B1 is 1-1/2". Calculations assume Member is Fully Braced. Design based on Dry Service Condition. Deflections less than 1/8"were ignored in the results. Fastener Manufacturer:TrussLok(tm) t 1J1. i nr 'D-tN C l '= CSL. ;..x Yom_�'�• Y' o � J Page 1 of 2 ®Boise Cascade Quadruple 1-314" x 20" VERSA-LAM® 2.0 3100 SP Floor Beam1B31-C Dry 1 span No cantilevers 10/12 slope June 30, 2016 16:13:20 BC CALC®Design Report Build 4516 File Name: 15325 Garage2 Job Name: 15-325 254 GREAT POND Description: Designs\B31-C Address: 254 GREAT POND Specifier: City, State, Zip: NORTH ANDOVER, MA Designer: Customer: Company: GELINAS STRUCTURAL ENGINEERING LLC Code reports: ESR-1040 Misc: Connection Diagram Disclosure b f-a Completeness and accuracy of input must be verified by anyone who would rely on a output as evidence of suitability for C particular application.Output here based on building code-accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with e current Installation Guide and applicable building codes.To obtain Installation Guide or ask questions,please call a minimum =2" c=8" (800)232-0788 before installation. b minimum =4" d =24" e minimum — 1" BC CALC®,BC FRAMER®,AJSTM, ALLJOIST®,BC RIM BOARD TM^,BCI®, Beams 7 inches wide will be assumed to be either top-loaded only, or equally loaded from BOISE GLULAMT"' SIMPLE FRAMING each side. SYSTEM®,VERSA-LAM®,VERSA-RIM PLUS®,VERSA-RIM®, All TrussLok screws may be installed from one side of multiple ply VERSA-LAM beams. VERSA-STRAND®,VERSA-STUD®are All TrussLok screws may be installed from one side of multiply Versa-Lam beams. trademarks of Boise Cascade wood Member has no side loads. Products L.L.C. Connectors are: FMTSL634 ®Boise Cascade Triple 1-314" x 24" VERSA-LAM® 2.0 3100 SP Floor Beam11331-D Dry 1 span No cantilevers 10/12 slope June 30, 2016 16:13:20 BC CALC®Design Report Build 4516 File Name: 15325 Garage2 Job Name: 15-325 254 GREAT POND Description: Designs\B31-D Address: 254 GREAT POND Specifier: City, State, Zip: NORTH ANDOVER, MA Designer: Customer: Company: GELINAS STRUCTURAL ENGINEERING LLC Code reports: ESR-1040 Misc: a i 6 5 3 2 i 25-00-00 BO 61 Total of Horizontal Design Spans=25-00-00 Reaction Summary (Down/ Uplift) (lbs) Bearing Live Dead Snow Wind Roof Live BO 4,750/0 4,237/0 5,469/0 B1 4,750/0 4,237/0 5,469/0 Live Dead Snow Wind Roof Live Trib. Load Summary Tag Description Load Type Ref. Start End 100% 90% 115% 160% 125% 1 FLOOR Unf.Area (Ib/ft"2) L 00-00-00 25-00-00 40 10 05-06-00 2 CEILING LOW Unf.Area (Ib/ft^2) L 00-00-00 25-00-00 20 10 02-06-00 3 ROOF HIGH Unf.Area (Ib/ft^2) L 00-00-00 25-00-00 10 50 05-09-00 4 WALL Unf. Lin. (Ib/ft) L 00-00-00 25-00-00 0 80 n/a 5 CEILING HIGH Unf.Area (Ib/ft^2) L 00-00-00 25-00-00 20 10 05-06-00 6 ROOF LOW Unf.Area (Ib/ft^2) L 00-00-00 25-00-00 10 50 03-00-00 Controls Summary Value %Allowable Duration Case Location Pos. Moment 74,384 ft-lbs 53.7% 115% 3 12-06-00 End Shear 9,928 lbs 36.1% 115% 3 02-00-14 Total Load Defl. L/434 (0.692") 55.3% n/a 3 12-06-00 Live Load Defl. L/673 (0.446") 53.5% n/a 6 12-06-00 Max Defl. 0.692" n/a n/a 3 12-06-00 Span/Depth 12.5 n/a n/a 0 00-00-00 Notes Entered/Displayed Horizontal Span Length(s) = Clear Span + 1/2 min. end bearing + 1/2 intermediate bearing Design meets Code minimum (L/240)Total load deflection criteria. Design meets Code minimum (U360) Live load deflection criteria. d+ s Minimum bearing length for BO is 3". `''N L Minimum bearing length for B1 is 3". Calculations assume Member is Fully Braced. Design based.on Dry Service Condition. Deflections less than 1/8"were ignored in the results. ., Fastener Manufacturer.TrussLok(tm) .{, Page I of 2 ®Boise' Cascade Triple 1-3/4" x 24" VERSA-LAM® 2.0 3100 SP Floor Beam1B31-D Dry 1 span No cantilevers 10/12 slope June 30, 2016 16:13:20 BC CALCO Design Report Build 4516 File Name: 15325 Garage2 Job Name: 15-325 254 GREAT POND Description: Designs\B31-D Address: 254 GREAT POND Specifier: City, State, Zip: NORTH ANDOVER, MA Designer: Customer: Company: GELINAS STRUCTURAL ENGINEERING LLC Code reports: ESR-1040 Misc: Connection Diagram Disclosure �►{ b d Completeness and accuracy of input must a be verified by anyone who would rely on a . . . output as evidence of suitability for C particular application.Output here based on building code-accepted design properties and analysis methods. 0 0 Installation of Boise Cascade engineered wood products must be in accordance with e - current Installation Guide and applicable building codes.To obtain Installation Guide or ask questions,please call a minimum =2" C= 10" (800)232-0788 before installation. b minimum =4" d =24" e minimum — 1" BC CALC@,BC FRAMER@,AJSTM, ALLJOIST@,BC RIM BOARD TM,BCI®, BOISE GLULAMTM^ SIMPLE FRAMING Calculated Side Load = 350.0 Ib/ft SYSTEM®,VERSA-LAM®,VERSA-RIM PLUS@,VERSA-RIM®, All TrussLok screws may be installed from one side of multiple ply VERSA-LAM beams. VERSA-STRAND@,VERSA-STUD®are All TrussLok screws may be installed from one side of multiply Versa-Lam beams. trademarks of Boise Cascade wood Connectors are: FMTSL005 Products L.L.C. ASN Boise Cascade Quadruple 1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP Floor Beam1B31-E Dry 1 span No cantilevers 10/12 slope June 30, 2016 16:13:20 BC CALC®Design Report Build 4516 File Name: 15325 Garage2 Job Name: 15-325 254 GREAT POND Description: Designs\B31-E Address: 254 GREAT POND Specifier: City, State, Zip: NORTH ANDOVER, MA Designer: , Customer: Company: GELINAS STRUCTURAL ENGINEERING LLC Code reports: ESR-1040 Misc: 3 2 1 , 13-00-00 AL BO 61 Total of Horizontal Design Spans=13-00-00 Reaction Summary (Down/ Uplift) (Ibs) Bearing Live Dead Snow Wind Roof Live BO 5,200/0 1,976/0 B1 5,200/0 1,976/0 Live Dead Snow Wind Roof Live Trib. Load Summary Tag Description Load Type Ref. Start End 100% 90% 115% 160% 125% 1 FLOOR Unf.Area (Ib/ft"2) L 00-00-00 13-00-00 30 10 10-00-00 2 ROOF Unf.Area (Ib/ft^2) L 00-00-00 13-00-00 50 10 10-00-00 3 WALL Unf. Lin. (Ib/ft) L 00-00-00 13-00-00 0 80 n/a Controls Summary Value %Allowable Duration Case Location Pos. Moment 23,324 ft-lbs 54.8% 100% 1 06-06-00 End Shear 6,003 lbs 38% 100% 1 01-00-12 Total Load Defl. L/430 (0.363") 55.9% n/a 1 06-06-00 Live Load Defl. L/593(0.263") 60.7% n/a 2 06-06-00 Max Defl. 0.363" n/a n/a 1 06-06-00 Span/Depth 13.1 n/a n/a 0 00-00-00 Notes Entered/Displayed Horizontal Span Length(s)= Clear Span + 1/2 min. end bearing + 1/2 intermediate bearing Design meets Code minimum (L/240)Total load deflection criteria. Design meets Code minimum (L/360) Live load deflection criteria. Minimum bearing length for BO is 1-1/2". Minimum bearing length for B1 is 1-1/2". Calculations assume Member is Fully Braced. R`y'e U" '`� r'+ Design based on Dry Service Condition. � ' yr , Deflections less than 1/8"were ignored in the results. ^` Fastener Manufacturer:TrussLok (tm) u rt. i v0 i ^4 ����,� Page 1 of 2 ®Boise Cascade Quadruple 1-314" x 11-718" VERSA-LAM® 2.0 3100 SP Floor Beam\B31-E Dry 1 span No cantilevers 10/12 slope June 30, 2016 16:13:20 BC CALC®Design Report Build 4516 File Name: 15325 Garage2 Job Name: 15-325 254 GREAT POND Description: Designs\B31-E Address: 254 GREAT POND Specifier: City, State, Zip: NORTH ANDOVER, MA Designer: Customer: Company: GELINAS STRUCTURAL ENGINEERING LLC Code reports: ESR-1040 Misc: Connection Diagram _ Disclosure �{ b d Completeness and accuracy of input must LI be verified by anyone who would rely on a output as evidence of suitability for • • • particular application.Output here based on building code-accepted design properties and analysis methods. • • • Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable e building codes.To obtain Installation Guide or ask questions,please call a minimum =2" c=7-7/8" (800)232-0788 before installation. b minimum =4" d =24" e minimum — 1" BC CALC®,BC FRAMER®,AJSTM, ALLJOIST®,BC RIM BOARD-,BCI®, Beams 7 inches wide will be assumed to be either top-loaded only, or equally loaded from BOISE GLULAMT" SIMPLE FRAMING each Side. SYSTEM®,VERSA-LAM®,VERSA-RIM PLUS®,VERSA-RIM®, All TrussLok screws may be installed from one side of multiple ply VERSA-LAM beams. VERSA-STRAND®,VERSA-STUD®are All TrussLok screws may be installed from one side of multiply Versa-Lam beams. trademarks of Boise Cascade wood Member has no side loads. Products L.L.C. Connectors are: FMTSL634 ®Boise Cascade Triple 1-3/4" x 9-1/2" VERSA-LAM® 2.0 3100 SP Floor Beam1HDR AT 1331-D_13 Dry 1 span No cantilevers 10/12 slope June 30, 2016 16:13:21 BC CALCO Design Report Build 4516 File Name: 15325 Garage2 Job Name: 15-325 254 GREAT POND Description: Designs\HDR AT B31-D_B Address: 254 GREAT POND Specifier: City, State, Zip: NORTH ANDOVER, MA Designer: Customer: Company: GELINAS STRUCTURAL ENGINEERING LLC Code reports: ESR-1040 Misc: i 04-00-00 BO 1311 Total of Horizontal Design Spans=04-00-00 Reaction Summary (Down/ Uplift) (lbs) Bearing Live Dead Snow Wind Roof Live BO 2,731 /0 2,539/0 3,109/0 B1 2,735/0 2,542/0 3,114/0 Live Dead Snow Wind Roof Live Trib. Load Summary Tag Description Load Type Ref. Start End 100% 90% 115% 160% 125% 1 PTLOAD FROM 24... Conc. Pt. (Ibs) L 02-00-00 02-00-00 5,466 5,023 6,223 n/a Controls Summary Value %Allowable Duration Case Location Pos. Moment 13,813 ft-lbs 57.4% 115% 3 02-00-00 End Shear 6,916 lbs 63.5% 115% 3 00-10-06 Total Load Defl. L/999 (0.042") n/a n/a 3 02-00-00 Live Load Defl. L/999 (0.027') n/a n/a 6 02-00-00 Max Defl. 0.042" n/a n/a 3 02-00-00 Span/Depth 5.1 n/a n/a 0 00-00-00 Notes Entered/Displayed Horizontal Span Length(s) Clear Span + 1/2 min. end bearing + 1/2 intermediate bearing Design meets Code minimum (L/240)Total load deflection criteria. Design meets Code minimum (L/360) Live load deflection criteria. Minimum bearing length for BO is 1-3/4". Minimum bearing length for 61 is 1-3/4". Calculations assume Member is Fully Braced. Design based on Dry Service Condition. Deflections less than 1/8"were ignored in the results. Fastener Manufacturer:TrussLok(tm) rh. L r,t' t (�1►/Bolsecascade Triple 1-3/4" x 9-112" VERSA-LAM® 2.0 3100 SP Floor Beam1HDR AT B31-D_B LTJ Dry 1 span No cantilevers 10/12 slope June 30, 2016 16:13:21 BC CALC®Design Report Build 4516 File Name: 15325 Garage2 Job Name: 15-325 254 GREAT POND Description: Designs\HDR AT B31-D_B Address: 254 GREAT POND Specifier: City, State, Zip: NORTH ANDOVER, MA Designer: Customer: Company: GELINAS STRUCTURAL ENGINEERING LLC Code reports: ESR-1040 Misc: Connection Diagram Disclosure �I b d Completeness and accuracy of input must LI be verified by anyone who would rely on a output as evidence of suitability for • • particular application.Output here based on building code-accepted design properties and analysis methods. • • • Installation of Boise Cascade engineered wood products must be in accordance with e current Installation Guide and applicable building codes.To obtain Installation Guide or ask questions,please call a minimum =2" c= 5-1/2" (800)232-0788 before installation. b minimum =4" d =24" e minimum — 1" BC CALC®,BC FRAMER®,AJSTM, ALLJOIST®,BC RIM BOARD TM^,BCI®, Connection design assumes point load is top-loaded. For connection design of side-loaded BOISE GLULAMT" SIMPLE FRAMING point loads, please consult a technical representative or professional of Record. SYSTEM®,VERSA-LAM®,VERSA-RIM PLUS®,VERSA-RIM®, All TrussLok screws may be installed from one side of multiple ply VERSA-LAM beams. VERSA-STRAND®,VERSA-STUD®are All TrussLok screws may be installed from one side of multiply Versa-Lam beams. trademarks of Boise Cascade wood Member has no side loads. Products L.L.C. Connectors are: FMTSL005 T J Boise Cascade Triple 1-3/4" x 18" VERSA-LAM® 2.0 3100 SP Roof Beam\111341 Dry 1 span No cantilevers 10/12 slope June 30, 2016 16:13:21 BC CALCO Design Report Build 4516 File Name: 15325 Garage2 Job Name: 15-325 254 GREAT POND Description: Designs\RB41 Address: 254 GREAT POND Specifier: City, State, Zip: NORTH ANDOVER, MA Designer: Customer: Company: GELINAS STRUCTURAL ENGINEERING LLC Code reports: ESR-1040 Misc: __�o 12 25-06-00 BO 61 Total of Horizontal Design Spans=25-06-00 Reaction Summary (Down/ Uplift) (lbs) Bearing Live Dead Snow Wind Roof Live BO 2,357/0 6,694/0 B1 2,357/0 6,694/0 Live Dead Snow Wind Roof Live Trib. Load Summary Tag Description Load Type Ref. Start End 100% 90% 115% 160% 125% 1 ROOF Unf.Area (Ib/ft^2) L 00-00-00 25-06-00 15 50 10-06-00 Controls Summary Value %Allowable Duration Case Location Pos. Moment 57,699 ft-lbs 71.7% 115% 4 12-09-00 End Shear 7,934 lbs 38.4% 115% 4 01-06-14 Total Load Defl. L/231 (1.323") 77.8% n/a 4 12-09-00 Live Load Defl. L/313 (0.979") 76.8% n/a 5 12-09-00 Max Defl. 1.323" n/a n/a 4 12-09-00 Span/Depth 17 n/a n/a 0 00-00-00 Cautions For roof members with slope (1/4)/12 or less final design must ensure that ponding instability will not occur. For roof members with slope (1/2)/12 or less final design must account for Rain-on-Snow surcharge load. Notes Entered/Displayed Horizontal Span Length(s)=Clear Span + 1/2 min. end bearing + 1/2 intermediate bearing Design meets Code minimum (L/180)Total load deflection criteria. Design meets Code minimum (L/240) Live load deflection criteria. Minimum bearing length for BO is 2-5/16". Minimum bearing length for B1 is 2-5/16". Calculations assume Member is Fully Braced. Design based on Dry Service Condition. .�? G! L Deflections less than 1/8"were ignored in the results. Fastener Manufacturer:TrussLok(tm) U elk .0 s; Page 1 of 2 Massachusetts =Department of Public Safety �i 11l �(�. Burd of Bu. ze aara�na�e.u�ec� a a- _j 'fairs Building Regulations and Standards. Office of Consumer At `f'9irs&Business Regulation Construction 5ti rvisorOIsr1E IMPROVEMENT CONTRACTOR License; CS-069599 , I i o egistration {138835 Type: •`��.►.jr.s ' xpiration:,_--5%21%20;1.7; Individual t KEVINFCiJN1VIF, `� N. I '1 ,"% 211 SEVEN STAW.' i KEVIN F.CUNNIFF`I�)`qln, - GROVELAND MA 01834 KEVIN CUNNIFF � 211 SEVEN STAR RDS Expiration GROVELAND, ISA 01834"-? Undersecretary Commissioner 09/29/2016 J• k= ! I 6 tr l�►)Boise Cascade y �.J Triple 1-3/4" x 18" VERSA-LAM® 2.0 3100 SP Roof BeamIRB41 Dry 1 span No cantilevers 10/12 slope June 30, 2016 16:13:21 BC CALC®Design Report Build 4516 File Name: 15325 Garage2 Job Name: 15-325 254 GREAT POND Description: Designs\RB41 Address: 254 GREAT POND Specifier: City, State, Zip: NORTH ANDOVER, MA Designer: Customer: Company: GELINAS STRUCTURAL ENGINEERING LLC Code reports: ESR-1040 Misc: Connection Diagram Disclosure �.I b d Completeness and accuracy of input must LI be verified by anyone who would rely on a output as evidence of suitability for • • • particular application.Output here based C on building code-accepted design �_ • properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with e k. current Installation Guide and applicable building codes.To obtain Installation Guide or ask questions,please call a minimum=2" c= 14" (800)232-0788 before installation. b minimum =4" d =24" e minimum — 1" BC CALC®,BC FRAMER®,AJSTM, ALLJOIST®,BC RIM BOARD TM,BCI®, All TrussLok screws may be installed from one side of multiple ply VERSA-LAM beams. BOISE GLULAMT" SIMPLE FRAMING All TrussLok screws may be installed from one side of multiply Versa-Lam beams. SYSTEM@,VERSA-LAM®,VERSA-RIM PLUS®,VERSA-RIM®, Member has no side loads. VERSA-STRAND®,VERSA-STUD®are Connectors are: FMTSL005 trademarks of Boise Cascade Wood Products L.L.C.