HomeMy WebLinkAboutBuilding Permit #346-15 - 26 DARTMOUTH STREET 10/8/2014 NORTFI q BUILDING PERMITo TOWN OF NORTH ANDOVER ;, r (,/ APPLICATION FOR PLAN EXAMINATI N Permit NO: 1t7 "J Date Received 0 •-� 'tl~ Date Issued: �9SSACHUS M ORTANT: A licant must complete all items on this page LOCATION 26 Dartmouth St Print PROPERTY OWNER Christopher Derby Print MAP NO: 210 PARCEL:023 ZONING DISTRICT: Historic District yesno Machine Shop Village yes no TYPE OF IMPROVEMENT PROPOSED USE Residential Non- Residential ❑ New Building []One family ❑Addition MTwo or more family ❑ Industrial ❑Alteration No. of units: ❑ Commercial ❑ Repair, replacement ❑Assessory Bldg ❑ Others: ❑ Demolition ❑✓Other Solar/PV ❑ Septic ❑Well ❑ Floodplain ❑ Wetlands Q Watershed District ❑ Water/Sewer Install 27 solar electric panels @6.885kW DC to roof of existing home, to be interconnected with the homes' electrical system Identification Please Type or Print Clearly) OWNER: Name: Christopher Derby Phone: (978)360-7012 Address: 26 Dartmouth St CONTRACTOR Name: Phone: 978-215=2360 SolarCity Corp Address: 800 Research Dr.Wilmington Ma.01887 Supervisor's Construction License: Exp. Date: 107663 8/29/2017 Home Improvement License: Exp. Date: 168572 3/8/2015 ARCHITECT/ENGINEER Phone: Address: Reg. No. FEE SCHEDULE.BULD/NG PERMIT.$12.00 PER$1000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PER S.F. Total Project Cost: $ 17,000 FEE: Check No.: ''1'I�;?-"1 I Receipt No.: NOTE: Persons contracting with unregistered contractors do not have access to the guaranty fund i of ure natAgent/Owner_ ! � g__-q-- _ Signature of contractor.k T��� L 1 ` IL NORTH BUILDING PERMIT °�S��Eo bq�o TOWN OF NORTH ANDOVER ?'y> '- . _ . °� APPLICATION FOR PLAN EXAMINATION * ,� Date Received �s94°R^re0�Pa` y Permit No#: qSs,, 5��� Date Issued: IMPORTANT: Applicant must complete all items on this page LOCATION Print PROPERTY OWNER Print 100 Year Structure yes no MAP PARCEL: ZONING DISTRICT:Historic District yes no Machine Shop Village yes no TYPE OF IMPROVEMENT PROPOSED USE Residential Non- Residential ❑ New Building ❑ One family ❑Addition ❑Two or more family ❑ Industrial ❑Alteration No. of units: ❑ Commercial ❑ Repair, replacement ❑Assessory Bldg ❑ Others: ❑ Demolition ❑ Other ❑ Septic ❑Well ❑ Floodplain ❑Wetlands ❑ Watershed District ❑Water/Sewer DESCRIPTION OF WORK TO BE PERFORMED: i Identification- Please Type or Print Clearly OWNER: Name: Phone: Address: Contractor Name: Phone: Address: Supervisor's Construction License: Exp. Date: Home Improvement License Exp. Date: _ ARCHITECT/ENGINEER Phone: Address: Reg. No. FEE SCHEDULE:BULDING PERMIT:$12.00 PER$1000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PER S.F. Total Project Cost: $ FEE: $ - Check No.: Receipt No.: N NOTE: Persons contracting with unregistered contractors do not have access to the guaranty fund Signature ofAgent/Owner Signature of contr«,;.tor Location —DA-g-�m az� 51"e+ No. Date u �� r • - TOWN OF NORTH ANDOVER ` • • Certificate of Occupancy $ Building/Frame Permit Fee $(q()4.67) Foundation Permit Fee $ Other Permit Fee $ TOTAL $ Check# Tz11 Building Inspector Location �`i Z Hers �✓�' . No. -i� 11Z —�� Date _, • - TOWN OF NORTH ANDOVER PK • „ Certificate of Occupancy $ Building/Frame Permit Fee $ Foundation Permit Fee $ Other Permit Fee TOTAL $ Check# �r v r: Building Inspector �l v Plans Submitted ❑ Plans Waived ❑ Certified Plot Plan ❑ Stamped Plans ❑ TYPE'OF SEWERAGE DISPOSAL Public Sewer ❑ Tanning/Massage/Body Art ❑ Swimming Pools ❑ Well ❑ Tobacco Sales ❑ Food Packaging/Sales ❑ Private(septic tank,etc. ❑ Permanent Dumpster on Site ❑ THE FOLLOWING SECTIONS FOR OFFICE USE ONLY INTERDEPARTMENTAL SIGN OFF - U FORM PLANNING & DEVELOPMENT Reviewed On Signature_ COMMENTS CONSERVATION Reviewed on Signature COMMENTS HEALTH Reviewed on Signature COMMENTS T4] 4 Zoning Board of Appeals: Variance, Petition No: Zoning Decision/receipt submitted yes Planning Board Decision: Comments Conservation Decision: Comments Water & Sewer Connection/Signature& Date Driveway Permit DPW Town Engineer: Signature: Located 384 Osgood Street FIRE DEPARTMENT - Temp Dumpster on site yes no Located at 124 Main Street Fire Department signature/date COMMENTS Dimension Number of Stories: Total square feet of floor area, based on Exterior. dimensions. Total land area, sq. ft.: ELECTRICAL: Movement of Meter location, mast or service drop requires approval of Electrical Inspector Yes No DANGER ZONE LITERATURE: Yes No MGL Chapter 166 Section 21A—F and G min.$100-$1000 fine NOTES and DATA — (For department use) ❑ Notified for pickup Call Email Date Time Contact Name Doc.Building Permit Revised 2014 Building Department The following is a list of the required forms to be filled out for the appropriate permit to be obtained. Roofing, Siding, Interior Rehabilitation Permits ❑ Building Permit Application o Workers Comp Affidavit ❑ Photo Copy Of H.I.C. And/Or C.S.L. Licenses ❑ Copy of Contract ❑ Floor Plan Or Proposed Interior Work ❑ Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit Addition Or Decks ❑ Building Permit Application ❑ Certified Surveyed Plot Plan ❑ Workers Comp Affidavit ❑ Photo Copy of H.I.C. And C.S.L. Licenses ❑ Copy Of Contract ❑ Floor/Cross Section/Elevation Plan Of Proposed Work With Sprinkler Plan And Hydraulic Calculations (If Applicable) ❑ Mass check Energy Compliance Report (If Applicable) ❑ Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign offrom Fire Department prior to issuance of Bldg Permit New Construction (Single and Two Family) ❑ Building Permit Application ❑ Certified Proposed Plot Plan ❑ Photo of H.I.C. And C.S.L. Licenses o Workers Comp Affidavit ❑ Two Sets of Building Plans (One To Be Returned) to Include Sprinkler Plan And Hydraulic Calculations If Applicable) ❑ Copy of Contract ❑ Mass check Energy Compliance Report ❑ Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg. Permit In all cases if a variance or special permit was required the Town Clerks office must stamp the decision from the Board of Appeals that the appeal period is over. The applicant must then get this recorded at the Registry of Deeds. One copy and proof of recording must be submitted with the building application Doc:Building Permit Revised 2014 i I NORTH Town of O �+ Zr a912614 h , ver, ss, COC MIC HE�WICK 4122601 RATEO I.P � ' S U BOARD OF HEALTH Food/Kitchen PER T L D Septic System bTHIS CERTIFIES THAT BUILDING INSPECTOR Foundation has permission to erect ........ ........ . .... buildings on .. ..... .. . .. .. . . .. ... .. s............. Rough to be occupied as � I y Chim e .0rovided that the person accepting this permit shall in every respect conform to the terms of the application Final on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection, Alteration and Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR Rough VIOLATION of the Zoning or Building Regulations Voids this Permit. Final PERMIT EXPIRES IN 6 MONTHS ELECTRICAL INSPECTOR UNLESS CONST TIO Rough . Service . ... ... .. .... Final BUILDING INS CT GAS INSPECTOR Occupancy Permit Required to Occupy Building Rough 1 Display in a Conspicuous Place on the Premises — Do Not Remove Final No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. Burner Street No. Smoke Det. GlCev�c i NORTFi Town of t EAndover No. - h ver, Mass, O COG NIC"IWIC.1 S U BOARD OF HEALTH T LD Food/Kitchen P E Rk I I Septic System 111 h THIS CERTIFIES THAT ... tow .. ............ .... ........... BUILDING INSPECTOR .... ... ............. .. . ..... ................ . .. �. ..:! � Foundation has permission to erect .......................... buildings o � � Rough to be occupied as . .Z. .... . .AS.... .... Chimney provided that the person accepting this permit shall in every respect conform to the terms of the application Final on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection, Alteration and Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR VIOLATION of the Zoning or Building Regulations Voids this Permit. Rough Final PERMIT EXPIRES IN 6 MONTHS ELECTRICAL INSPECTOR UNLESS CONSTRUCTI STARTS Rough Service ............. .... A ......:.................................... Final i BUILDING INSPECTOR GAS INSPECTOR Occupancy Permit Required to Occupy Building Rough Display in a Conspicuous Place on the Premises — Do Not Remove Fina' No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. Burner Street No. Smoke Det. 0 tl Massachuseas Electric Company M.D.P.U.No.1 176 1 Nantucket Electric Company Canceling M.D.T,E,No. 1116-A STANDARDS FOR rNTERCONNECTING DISTRIBUTED GENERATION ATTACHMENT 2 Certificate of Completion for Simplified Process Interconnections Installation Information: Check ii'owner-instalred CustomerorCompany Name(print); SolarCity Corp. Contact Person,if Company: Interconnection Admin Mailing Address: 3055 Clearview Way City: San Mateo State: CA Zip Code: 94402 Telephone (Primary): 702-703-8981 Telephone(Secondary): F,,: 650-240-1672 Email: interconnection.ma@solarcity.com Facility Address(If different from above): 26 Dartmouth St City: Notch Andover state: MA zip Code: 01845 Account Number: Meter Number: Electrical Contractor's Company or Name(print): SolarCity Corp. Electrician Narne,if Company. Matthew T. Markham Mailing Address: 24 St. Martin Drive City: Marlborough state: MA Zip Code: 01752 Telephone (Primary): 774-258-8505 Telephone(Secondary): 978-995-6584 Fax: 978-429-0898 Email: mmarkham@solarcity.com License number: MR1136 Date of approval to install Facility granted by the Company: Application ID number: Inspection: The system has been installed and inspected in compliance with the local guilding/Electrical Code of: North Andover (CityrlbvIi) Signed(Local Electrical Wiring Inspector,or attach signed electrical inspection): pjzti:;� 0 Wiring InspeetorName(printed): (f Phone Number: Email Address: / r�dlL7" IV 17t rl�o,�lH�lySc��71�� As acondition of interconnection.you are required to email a copy of'this form along with a copy of the signed electrical permit to distributed.generation@us.ngrid.com • ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. 1 CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING P01 POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 THREE LINE DIAGRAM LICENSE GENERAL NOTES Cutsheets Attached GEN #168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION ELEC 1136 MR OF THE MA STATE BUILDING CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: ZEP SOLAR 114 AHJ: North Andover REV BY DATE COMMENTS REV A NAME DATE COMMENTS UTILITY: National Grid USA (Massachusetts Electric) : 133 CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBEkPREMISE OWNER: DESCRIPTION: DESIGN: JB-01 81013 0 0 CONTAINED SHALL NOT BE USED FOR THE DERBY, CHRISTOPHER DERBY RESIDENCE Todd Beachley �SolarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: • a NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 26 DARTMOUTH ST 6.885 KW PV ARRAY Or • PART TO OTHERS OUTSIDE THE RECIPIENTS [MODULES: NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH24 St. Martin Drive, Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (27) CANADIAN SOLAR # CS6P-255PX SHEET: REV DATE Marlborough, MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PACE NAME: T. (650)638-1028 F: (650) 638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE5000A—USOOOSNR2 (978) 360-7012 COVER SHEET PV 1 10/1/2014 (888)—SOL-CITY(765-2489) www.solarcity.com PITCH: 38 ARRAY PITCH:38 MP1 AZIMUTH: 145 ARRAY AZIMUTH: 145 MATERIAL: Comp Shingle STORY: 2 Stories YOO JIM K No.4 AL Digitally oo Jin Kim Date:2014.10.01 08:21:59 -OT00' LEGEND E IS (E) UTILITY METER & WARNING LABEL lnv INVERTER W/ INTEGRATED DC DISCO Inv & WARNING LABELS DC DISCONNECT & WARNING LABELS AC © ® AC DISCONNECT & WARNING LABELS AC O DC JUNCTION/COMBINER BOX & LABELS —4 — — EF] Mpg D M DISTRIBUTION PANEL. & LABELS Lc LOAD CENTER & WARNING LABELS A O DEDICATED PV SYSTEM METER Q STANDOFF LOCATIONS Front Of HouseCONDUIT RUN ON EXTERIOR --- CONDUIT RUN ON INTERIOR GATE/FENCE Q HEAT PRODUCING VENTS ARE RED INTERIOR EQUIPMENT IS DASHED L---J SITE PLAN Scale: 1/8" = 1' 0 1' 8' 16' S F CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: PREMISE OBNER: DESCRIPTION: DESIGN: JB-0181013 00 CONTAINED SHALL NOT BE USED FOR THE DERBY, CHRISTOPHER DERBY RESIDENCE Todd Beachley BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �OI�� '�� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 26 DARTMOUTH ST 6.885 KW PV ARRAY wA PART TO OTHERS OUTSIDE THE RECIPIENT'S MooutEs �' NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH r THE SALE AND USE OF THE RESPECTIVE (27) CANADIAN SOLAR # CS6P-255PX 24 St. MartiinoDriive. Building 2, Unit 11 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEET: REV DATE T. (650)638-1028 F A(650) 638-1029 PERM�ION of SOLARCITY INC. SOLAREDGE SE5000A—USOOOSNR2 (978) 360-7012 SITE PLAN PV 2 10/1/2014 (BBB)-SOL- (765-2489) �.sole.citr.c«n PV MODULE (E) 2x4 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. ZEP COMP MOUNT C S1 ZEP FLASHING C (3) (3) INSERT FLASHING. (E) COMP. SHINGLE (4) PLACE MOUNT. 4" -10" B. (1) (E) LBW (E) ROOF DECKING (2) (5) INSTALL LAG BOLT WITH SIDE VIEW OF MP1 rvTs 5/16" DIA STAINLESS (5) SEALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH WITH SEALING WASHER (6) BOLT & WASHERS. MPI JX-SPACINGX-CANTILEVER Y-SPACING Y-CANTILEVER NOTES (2-1/2" EMBED, MIN) LANDSCAPE 64" 1 24" STAGGERED PORTRAIT 1 48° 1 20" (E) RAFTER C RAFTER 2X6 @ 16"OC ROOF AZ145 PITCH 38 STAN DO F F ARRAY AZI 145 PITCH 38 STORIES:2 C.J. 2x4 @16"OC Comp Shingle 1 „ , Scale: 1 1/2 = 1 �yaN OF y Y00 JN K No.4 T DINAL Digitally oo Jin Kim Date:2014.10.01 08:21:53 -07'00' CONFIDENTIAL— THE INFORMATION HEREIN [INVERTER: NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: JB-0181013 00 CONTAINED SHALL NOT E USED FOR THE DERBY, CHRISTOPHER DERBY RESIDENCE Todd Beachley ':,;SolarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NTING SYSTEM: .��� NOR SHALL IT BE DISCLOSED IN WHOLE OR INm Mount T e C 26 DARTMOUTH ST 6.885 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS u�s NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St. Martin Drive, Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE 7) CANADIAN SOLAR # CS6P-255PX SPIFFY: REV DATE Marlborough, MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME T: (650)638-1028 F: (650) 638-1029 PERMISSION OF SOLARCITY INC. LAREDGE SE5000A—USOOOSNR2 (978) 360-7012 STRUCTURAL VIEWS PV 3 10/1/2014 (BBB)-SOL-aTY(765-2489) www.salaraity.aom GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO TWO (N) GROUND Panel Number: G303OB1100CU Inv 1: DC Ungrounded GEN #168572 INV 1 -(1)SOLAREDGE�SE5000A-USOOOSNR� LABEL: A -(27)CANADIAN SOLAR__# CS6P-255PX ODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:12807471 Tie-In: Supply Side Connection Inverter; 50 OW, 240V, 97.574 w Unifed Disco and ZB,RGM,AFCI PV Module; 255 234.3W PTC, Black Frame, MC4, ZEP Enabled ELEC 1136 MR Overhead Service Entrance INV 2 Voc: 37.4 Vpmax: 30.2 INV 3 1 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 150A MAIN SERVICE PANEL E 10OA/2P MAIN CIRCUIT BREAKER (E) WIRING CUTLER-HAMMER Inverter L Disconnect CUTLER-HAMMER 100A 2P 5 Disconnect 6EGC1 SOLAREDGE SE5000A-USOOOSNR2 B 30A C ZDV SolarCity 2 LA 1 - - - 2 DG+ u B 3 PF DG MP 1: 1x13 -------------- ----------- _ DC+ DC+ - - I --MP 1: 1x14 - GEC �N DG DC- I EGC -- '---- --- EGC -- ----- - -- J r----J GND -- ---------------------------- I TO MSP N I I o I z z I c� I GEC ' To 120/240V SINGLE PHASE I I UTILITY SERVICE I I I I MAIN BREAKER I I I PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Voc* = MAX VOC AT MIN TEMP POIS2)Ground Rod; 5/8' x 8', Copper B (I)CUTLER-HAMMER III DG222NRB /r♦ A (1)SolarCit #4 STRING JUNCTION BOX D� - 2)ILSCO IPC 4/0- 6 Disconnect; 60A, 24OVac, Fusible, NEMA 3R /y 2x2 S�RMGS, UNFUSED, GROUNDED Insulation Piercing Connector; Main 4/0-4, Tap 6-14 S C (1)CUTLER-HAMMER /DG221UR6 PV (z7)SOLAREDGE 3oo-2NA4AZS SUPPLY SIDE CONNECTION. DISCONNECTING MEANS SHALL BE SUITABLI Disconnect; 30A, 24OVac, Non-Fusible, NEMA 3R PowerBox timizer, 30OW, H4, DC to DC, ZEP AS SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. -(I)CUTLER-�iAMMER j DG030NB Ground/Neutral It, 30A, General Duty(DG) nd (1)AWG /6, Solid Bare Copper -(1)Ground Rod; 5/8' x 8', Copper (N) ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION NO. 2, ADDITIONAL ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE O��T 1 AWG ¢6, THWN-2, Black 1 AWG $10, THWN-2, Black 1 AWG ¢8, THWN-2, Black Voc* =500 VDC Isc =30 ADC (2)AWG #10, PV WIRE, Black Voc* =500 VDC Isc =15 ADC IUF (1)AWG/6, THWN-2, Red ®I�L(11)AWG #10, THWN-2, Red O (1)AWG /8, THWN-2, Red Vmp =350 VDC Imp=19.42 ADC O (1)AWG J6, Solid Bare Copper EGC Vmp =350 VDC Imp=9.35 ADC IL.=LL(1)AWG/6, THWN-2, White NEUTRAL Vmp =240 VAC Imp=20.83AAC III^����LLL(I)AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=20.83AAC (1)AWG /10, THWN-2, Green EGC, , 7 59Conduit Kit;_3/4'.EMT -(1)AWG #6,,Solid Bore.Copper_ GEC. . . -(1)Conduit.Kit;•3/4'.EMT. . . . . . . . . . . . . . . . .-(1 AWG #8,.Tl{WN-2,_Green . . EGC/GEC (1)Conduit.Kit;.3/4'.EMT, w (2)AWG #t10, PV WIRE, Black . . . . Voc* =500 VDC Isc =15 4bt 1 / 1�(1)AWG #6, Solid Bare Copper EGC Vmp =350 VDC Imp=10.07 ADC . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: J B-0181013 00 PREMISE OWNER: DESCRIPTION: DESIGN: CBONTAINED SHALL NOT BE USED FOR THE DERBY, CHRISTOPHER DERBY RESIDENCE Todd Beachley "49�\`!a SolarCit . O EFIT OF SHALL TNBENDISCLOSED N WHCITY OLE ORCIN MOUNTING SYSTEM: 26 DARTMOUTH ST 6.885 KW PV ARRAY -►�� y PART TO OTHERS OUTSIDE THE RECIPIENT'S Comp Mount Type C ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: NORTH ANDOVER, MA 01845 24 St. Martin Drive, Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (27) CANADIAN SOLAR # CS6P-255PX PAGE NAME SHEET: REV DATE Marlborough, MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T: (650) 638-1028 F: (650)638-1029 PERM!S$ION OF SOLARCITY INC. SOLAREDGE SE5000A-USOOOSNR2 (978) 360-7012 THREE LINE DIAGRAM PV 4 10/1/2014 (888)-SOL-CITY(765-2489) www.solarcity.com Label Location: Label Location: Label Location: WARNING:PHOTOVOLTAIC POWER SOURCE � �� � ' � D Per Code: ��WARNING. �� � _r Code: WARNING Per NEC 690.31.G.3NEC EL'ECTRIG S�iOCK HAZARD . ELECTRIC SHOCK HAZARD E NEC - DONOTTOUCH'TERNIINALS THE.DC CONDUCTORS OF THIS •- • •n: TO BE LOAD SIDES'MAYBE ENERGIZED UNGROUNDED AND PHOTOVOLTAIC DC (DC) (INV) INVERTERIS IN THE;OPEN POSITION MAY BE ENERGIZED DISCONNECTPer Code: a d .. d1 „ ter UNGROUNDED NEC 6.0 Label Location: Label Location: WARNING (POI) MAXIMUM POWER- Per •• POINT CURRENT Im A--- ._( '•_ - INVERTER OUTPUT p}- CONNECTION 690.64.B.7 MAXIMUM POWER VNEC 690.53 LONDON= POINT VOLTAGE(Vmp}_ MAXIMUM SYSTEM THIS OVERCURRENT VOLTAGE(Voc}_v DEVICE: SHORT-CIRCUIT CURRENT(Isc)�A Label • • PHOTOVOLTAIC POINT OF -• Label • • INTERCONNECTION Code: WARNING' ELECTRIC SHOCK NEC 690.17.4; 690.54 Per WARNING HAZARD. DO NOT TOUCH ' Code: NEC TERMINALS.TERMINALS ON ELECTRICAL SHOCK HAZARD BOTH THE LINE AND LOAD SIDE DO NOT-TOUCH TERMINALS MAY BE ENERGIZED IN THE OPEN TERMINALS ON BOTH LINE AND POSITION. FOR.SERVICE LOAD SIDES MAY BE ENERGIZED DE-ENERGIZE BOTH SOURCE IN THE OPEN POSITION AND MAIN BREAKER. - -- DG VOLTAGE IS - PV POWER-SOURCE ALWAYS PRESENT-WHEN MAXIMUM AC - :SOLAR MODULES ARE OPERATING CURRENT A EXPOSED TO SUNLIGHT MAXIMUM AC OPERATING VOLTAGE V Label • • WARNINGLocation: Per ELECTRIC SHOCK HAZARD �•; CAUTION ' (POI) NEC _ IF A GROUND FAULT IS INDICATED PHOTOVOLTAIC SYSTEM NORMALLY GROUNDED CIRCUIT IS BACKFED 690.64.13.4 CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED Label • • - (POI AC A (POI) DUAL POWER SOURCE ••- Per Code: PHOTOVOLTAIC SYSTEM 690.64.13.4 Conduit NEC 6.0 :. Interior(D): Distribution Panel (DC): DC Disconnect • Label Location: (INV): Inverter With Integrated DC Disconnect MAXIMUM AC A -OI) (LC): Load Center CURRENTPer Code: AC VNEC 690.54 -• Point of • • OPERATING VOLTAGE ■!mu muu■■■m ■u ■mm■ - wuuu • . a • • r Label uuimivauun:m■■uunm■■w■uumn■ � • � . I , wmw:• n w:wnuuwnu■uuu�nniruc■ SolarCity SleekMountTM - Comp SolarCity SleekMountTM - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed ,. Installation Instructions is optimized to achieve superior strength and Zep Compatible TM modules aesthetics while minimizing roof disruption and O Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and • Interlock and grounding devices in system UL listed to UL 2703 Fastener Size Per NDS Section 1.1.3.2 mounting clamps, combined with the addition / t� Seal pilot hole with roofing sealant of array trim and a lower profile all contribute • Interlock and Ground Zep ETL listed to UL 1703 to a more visually appealing system.SleekMount as"Grounding and Bonding System" 0 Insert Comp Mount flashing under upper utilizes Zep Compatible TM modules with •Ground Zep UL and ETL listed to UL 467 as layer of shingle strengthened frames that attach directly to grounding device Zep Solar standoffs, effectively eliminating the ® Place Comp Mount centered need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition •Anodized components for corrosion resistance O Install lag pursuant to NDS Section 11.1.3 shingles are not required to be cut for this \ with sealing washer. system, allowing for minimal roof disturbance. •Applicable for vent spanning functions ® Secure Leveling Foot to the Comp Mount using machine Screw O7 Place module ® Components O5/16"Machine Screw OLeveling Foot © Lag Screw ® Comp Mount OComp Mount Flashing C 0 O f •"kid, �`OMPgTB` I. -�kddI � January 2013 �1� V� LISTED SolarCity. s0la�lty® January 2013 DMPP e� d�ee5,�� ©��� CS6P-235/240/245/250/255PX N h _r CanadianSolar Electrical Data Black-framed gfeakthfO°� STC CS6P-235P CS6P-240P CS6P-245P CS6P-250PXCS6P-255PX Temperature Characteristics Nominal Maximum Power(Pmax) 235W 240W 245W 250W 255W _ _ Optimum Operating Voltage(Vmp) 29.8V 29.9V 30.OV 30.1V 30.2V Pmax -0.43%/•C Optimum Operating Current(Imp) 7.90A 8.03A 8.17A 8.30A 8.43A Temperature Coefficient Voc -0.34%/•C Open Circuit Voltage(Voc) 36.9V 37.OV 37.1V 37.2V 37AV Isc 0.065%/°C - Short Circuit Current(Isc) 8.46A 8.59A 8.74A 8.87A 9.00A Normal Operating Cell Temperature 45±2°C • • - • • Module Efficiency 14.61% 14.92% 15.23% 1 15.54% 15.85% Operating Temperature -40•C-+85°C Performance at Low Irradiance Maximum System Voltage 1000V IEC /600v UL Industry leading performance at low irradiation Maximum Series Fuse Rating 15A environment,+95.5%module efficiency from an Application Classification ClassA irradiance of 1000w/m'to 200w/m' Power Tolerance 0-+5W (AM 1.5,25`C) Next Generation Solar Module Under Standard Test Conditions(STC)ofirradiance of 1000W/m',spectrum AM 1.5 and celitemperature of25C NewEdge,the next generation module designed for multiple Engineering Drawings NOCT__ CS6P-235PX C86P-240PX CS6P-245PX CS6P-250PX CS6P-255PX types of mounting systems,offers customers the added Nominal Maximum Power (Pmax) 170W 174W 178W 181W 185W value of minimal system costs,aesthetic seamless Optimum Operating Voltage(Vmp) 27.2V 27.3V 27AV 27.5V 27.5V (— appearance,auto groundingand theft resistance. Optimum Operating Current(Imp) 6.27A 6.38A 6.49A 6.60A 6.71A Open Circuit Voltage(Voc) 33.9V 34.OV 34.1V 34.2V 34AV The black-framed CS6P-PX is a robust 60 cell solar module Short Circuit Current(Isc) 6.86A 6.96A 7.08A 7.19A 7.29A incorporating the groundbreaking Zep compatible frame. Under Normal Operating Cell Temperature,Irradiance of 600 W/m',spectrum AM 1.5,ambient temperature 201x, The specially designed frame allows for rail-free fast wind speed 1 m/s I IM installation with the industry's most reliable grounding Mechanical Data system.The module uses high efficiency poly-crystalline Cell Type Poly-crystalline 156 x 156mm,2 or 3 Busbars Key Features silicon cells laminated with a white back sheet and framed Cell Arrangement 60(6 x 10) with black anodized aluminum.The black-framed CS6P-PX Dimensions 1638 x 982 x 40mm(64.5 x 38.7 x 1.571n) • Quick and easy to install - dramatically is the perfect choice for customers who are looking for a high Weight 20.5kg(45.2 lbs) reduces installation time quality aesthetic module with lowest system cost. Front Cover 3.2mm Tempered glass Frame Material Anodized aluminium alloy • Lower system costs - can cut rooftop i-Box IP65,3 diodes 112 installation costs in half Best Quality • 235 quality control points in module production Cable 4mm'(IEC)/12AWG(Ul_),1000mm Connectors MC4 or MC4 Comparable • Aesthetic seamless appearance - low profile • EL screening to eliminate product defects Standard Packaging(Modules per Pallet) 2apos with auto leveling and alignment • Current binning to improve system performance Module Pieces ginger (Modules s p ft.container) s7zpcs(4o HQ> • Accredited Salt mist resistant • Built-in hyper-bonded grounding system - if it's 1-V Curves (CS6P-255PX) mounted,it's grounded Best Warranty Insurance 1] „ , I • Theft resistant hardware • 25 years worldwide coverage + a • 100%warranty term coverage P I , f Section A-A • Ultra-low parts count - 3 parts for the mounting Providing third party bankruptcy rights 7i 35.7 and grounding system • Non-cancellable • Immediat • e coverage p Industry first comprehensive warranty insurance by AM Best rated leading insurance companies in the • Insured by 3 world top insurance companies o „_o,,, i world ' I Comprehensive Certificates , = -m� _ 1_5. • Industry leading plus only power tolerance:0--+5W IEC 61215,IEC 61730, IEC61701 ED2,UL1703, e , --`'"' —"` t5 40 <. • Backward compatibility with all standard rooftop and CEC Listed,CE and MCS ground mounting systems • IS09001:2008:Quality Management System • ISO/TS16949:2009:The automotive quality Specifications included in this datasheet are subject to change without prior notice. • Backed By Our New 10/25 Linear Power Warranty management system Plus our added 25 year insurance coverage • IS014001:2004:Standards for Environmental About Canadian Solar management system Canadian Solar Inc. is one of the world's largest solar Canadian Solar was founded in Canada in 2001 and was 7097% Adde • QC080000 HSPM:The Certification for companies. As a leading vertically-integrated successfully listed on NASDAQ Exchange (symbol: CSIQ) in d Value F manufacturer of ingots,wafers,cells,solar modules and November 2006. Canadian Solar has module manufacturing so% rOm Warranty Hazardous Substances Regulations solar systems, Canadian Solar delivers solar power capacity of 2.05GW and cell manufacturing capacity of 1.3GW. • OHSAS 18001:2007 International standards for products of uncompromising quality to worldwide so% occupational health and safety customers. Canadian Solar's world class team of °% • REACH Compliance professionals works closely with our customers to 5 10 1s 20 2s P provide them with solutions for all their solar needs. 'rters 1545 p__ . • • 10 year product warranty on materials and workmanship s aE � s^p- L .r `a' a� Tel:+1 519 837 1881 • 10 year linear power output warranty o& C�,C E� 1 E6 I Canada �i_SCt vFax:+1 519 837 2550 di WWW.Canadiansolar.com EN-Rev 10.17 Copyright 0 2012 Canadian Solar Inc. � =gg SolarEd a Power 0 timizer solar - • . solar g p Module Add-On for North America P300 / P350 / P400 SolarEdge Power Optimizer P300 P350 P400 Module Add-On For North America (for 60-cell PV (for 72-cell PV (for 96-cell PV modules) modules) modules) P300 / P350 / P400 INPUT Rated Input D.Power•' 300 350 400 W Absolute Maximum Input Voltage Voc at lowest tem erature 48 60 80 Vdc .............................................................................. .............................................................................................. MPPT Operating Range 8-48 ..8-60. ... 8-80 Vdc . Maximum Short CircuitCurrent.(Isc)............................... .................................. ..io..................................... .Adc ... Maximum DC Input Current ..12.5................................................Adc .... ....................... .............................................................................................. Maximum Efficien 99.5 .............................................................................................................................................................................. Weighted Efficiency98.8 % .............................................................................. ................................................................................................ Overvoltage Category 11 OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) _ Maximum Output Current 15 Adc Maximum Output Voltage I 60 I Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) TT- Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE ' EMCFCC Part15 Class B,IEC61000-6-2,IEC61000-6-3 ................................................................................................................................................................. ............. Safety.........................................................................................IEC62109-1(class II safetYl.UL3741 RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage0 Vdc .....................................................................................................................10...0......................................... ............. Dimensions(WxLx H) 141x212x40.5/S.SSx8.34x1.59 mm /in ..................................................................................................................................................... Weight(including cables) 950/2.1 gr/Ib ................................................................................................................................................................. ............. Input Connector MC4/Amphenol/Tyco Output Wire Type/Connector Double Insulated;Amphenol ............................................................................................................................................................................ Output Wire Length 0.95/3.0.......I.......................1:Z.�3:9........................ m/ft .............................................................................. ................... ............ V Operating Temperature Range........................................ .............................40_+85/-40.+185................................� �F... Protection RatingIP65/NEMA4 .............................................................................. ................................................................................... ............. Relative Humidity .............................................................................................0.-.100..........................................9�° '�'Rated STC power&[M1e mpdule.M-1—P uP to�5%power tdmlm It— PV SYSTEM DESIGN USING A SOLAREDGE SINGLE PHASE THREE PHASE THREE PHASE INVERTER 208V 480V ' PV power optimization at the Module-level Minimum StringLength(PowerOptimizers) 8 10 18 ................................................................... ........................... ................................................................... Up[0 25%more energy Maximum String Length(Power Optimizers) 25 25 50 ........................................................................................................................................................................ Maximum Power per String 5250 6000 12750 W - Superior efficient 99.5% ............................................................................................................................................................................ p y( ) Parallel Strings of Different Lengths or Orientations Yes - Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading """' """"'......-""""""""'......""""""'"""" - Flexible system design for maximum space utilization - Fast installation with a single bolt , - Next generation maintenance with module-level monitoring - Module-level voltage shutdown for installer and firefighter safety USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us "4 The Commonwealth of Massachusetts Department of Industrial Accidents • — Ogee of Investigations 1 Congress Street,Suite 100 ` Boston,MA 02114-2017 www.mass.gov/dia Workers'Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Analicant Information Please Print Lezibly Name(Business/Organization/Individual): SOLARCITY CORP Address:3055 CLEARVIEW WAY i City/State/Zip:SAN MATEO, CA 94402 Phone#:888-765-2489 Are you an employer?Check the appropriate box: Type of project(required): 1. 1 am a employer with 5000 4. ❑ I am a general contractor and 1 6. ❑New construction employees(full and/or part-time).* have hired the sub-contractors 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have g, ❑ Demolition working for me in any capacity. employees and have workers' 9. ❑ Building addition [No workers' comp. insurance romp. insurance.; required.] 5. ❑ We are a corporation and its 10.❑ Electrical repairs or additions 3.❑ 1 am a homeowner doing all work officers have exercised their 11.❑ Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs insurance required.] t c. 152,§1(4),and we have no SOLAR/PV employees. [No workers' 13.Q Other comp. insurance required.] *Any applicant that checks box#l must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. tContractors that chock this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that Is providing workers'compensation insurance for my employees. Below is the policy and job site Information. Insurance Company Name:LIBERTY MUTUAL INSURANCE COMPANY Policy#or Self-ins. Lic. #:WA7-66D-066265-024 Expiration Date:09/0, GL111/2,0115 Job Site Address:�0 aMo,)±j) V- City/State/Zip: 4)+ I�77 C e Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required-under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby cert rtnrler the pains and penalties ojperjtrry flint the hiformaldon providedabove is true and correct. Signature: ---- ` t Date: Phon #: Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2. Building Department 3.City/Town Clerk 4. Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: ^ D 1 ® DATE(MMIDDIYYYn ACOOR n CERTIFICATE OF LIABILITY INSURANCE 0812912014 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER C NTA T MARSH RISK 8 INSURANCE SERVICES NAME: NE IFAX 345 CALIFORNIA STREET,SUITE 1300 JAICO.N •fxl) AIC,"0: CALIFORNIA LICENSE NO.0437153 EMAIL SAN FRANCISCO,CA 94104 ADDRESS; INSURERS)AFFORDING COVERAGE _ NA_IC# 998301-STND-GAWUE-14-15 rINSURER A:Liberty Mutual Fire Insurance Company _ 16586 INSURED _ S:Liberty Insurance Corporation 42404 Ph(650)963.5100 SolarCity Corporation C:NIAN/A3055 Clearview Way D: San Mateo,CA 94402 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: SEA-00244026902 REVISION NUMBER:4 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL UB POLICY EFF POLICY EXP LIMITS IM POLICY NUMBER MMIDD MMIDD Y A GENERAL LIABILITY TB2-661-066265.014 09/0112014 0910112015 EACH OCCURRENCE s 1,00O,OOD DAMA E TO RENTED 100,000 X COMMERCIAL GENERAL LIABILITY PREMISES E_{_a occurrence $ _ a MED EXP(Any one person) $ 10,000 CLAIMS-MADE OCCUR PERSONAL&ADV INJURY $ 1'000'000 GENERAL AGGREGATE $ 2,000,000 GEN'L AGGREGATE X ATE LIMIT APPLIES PER: PRODUCTS-COMPIOP.AGG $ 2,000,000 X POLICY PRO- Deductible $ 25,000 LOC A AUTOMOBILE LIABILITY AS2-661-066265.044 09101/2014 0910112015 COMBINED SINGLE LIMIT 1004000 Ea awident) _ rXX ANY AUTO BODILY INJURY(Per person) $ALL OWNED SCHEDULED BODILY INJURY(Per accident) $ NON•OWNED PROPERTY DAMAGE $ AUTOS HIRED AUTOS XAUTOS (Per accident)Phys.Damage COMPICOLLDED: $ $1,000!$1,000 UMBRELLA LIAB OCCUR r_2A��GGREGATE H OCCURRENCE $ _ EXCESS UAB CLAIMS-MADE $ DED RETENTION$ $ B WORKERSCOMPENSATION WA7-66D-066265-024 0910112014 09/0112015 WC sTATU- OTH- AND EMPLOYERS'LIABILITY 9BYI IM ER ._. B YIN WC7-661-066265-034(WI) 09/0112014 09101/2015E L EACH ACCIDENT $ 1,000,000 ANY PROPRIETORMARTNERIEXECUTIVE B OFFICERIMEMBER EXCLUDED? a NIA WC DEDUCTIBLE:5350,000 1,000,000 (Mandatory In NH) E L.DISEASE-EA EMPLOYEE $ If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E L DISEASE•POLICY LIMIT $ DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (Attach ACORD 101,Additional Remarks Schedule,if more space Is required) Evidence of Insurance. CERTIFICATE HOLDER CANCELLATION SolarCity Corporation SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 3055 ClearView Way THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN San Mateo,CA 94402 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh Risk&Insurance Services Charles Marmolejo ©1988.2010 ACORD CORPORATION. All rights reserved. ACORD 25(20101`05) The ACORD name and logo are registered marks of ACORD ,q (r 0/Ye/Y/0j//tIN't///1r� rlr16r1li Office of Consumer Affairs/and Business Regulation 4,0 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 168572 Type: Supplement Card SOLARCITY CORPORATION Expiration: 3/8/2015 CRAIG ELLS 24 ST. MARTIN STREET BLD 2 UNIT 11 - - - — -- - -- ------ MARLBOROUGH, MA 01752 Update Address and return card.Mark reason for change. SCA I Co 20M tss.11 [] Address [� Renewal [] Employment [J Lost Card Office of Consumer Affairs&Business Regulation License or registration valid for individul use only Y SOME IMPROVEMENT CONTRACTOR before the expiration date. If found return to: rF a' Office of Consumer Affairs and Business Regulation to- - Registration: 168572 Typc 10 park Plaza-Suite 5170 Expiration: 3/8/2015 Supplement :ard Boston,MA 02116 SOLARCITY CORPORATION CRAIG ELLS 24 ST MARTIN STREET BLD 2UNI � --y6 if F,�s` _ TAAALBOROUGH,MA 01752 —with-'out Undersecretary Not v lid signature "Massachusetts •Department of 0,,t)oc Satet, Board of Budding Reguiat+ons ard Stanuaras f ffn.tlIlk h+ut ~1111+ItIs"t :.cense CS-107663 fn. CRAIG ELLS s ,� _ 206 BAKER STREET Keene NH 03431 I � o..��'�6�c.. • fir n , Unum+s,ur+r++ 08129/2017 K n�ll� (�C1llllllfll�tl.�C�fll�11 t? Cll ` Office of Consumer Affairs d Business Regulation . y 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 168572 Type: Supplement Card SOLAR CITY CORPORATION Expiration: 3/8/2015 ASTRID BLANCO ----- - - 24 ST. MARTIN STREET BLD 2 UNIT 11 - - MARLBOROUGH, MA 01752 Update Address and return card.Mark reason for change. SCA 1 0 20M-05!11 Address [I Renewal [-] Employment ❑ Lost Card ffice of Consumer Affairs&Business Regulation License or registration valid for individul use only wp ' {SME IMPROVEMENT CONTRACTOR before the expiration date. if found return to: t r'Ir Office of Consumer Affairs and Business Regulation 4 '.lRegistration: 168572 Type: 10 Park Plaza-Suite 5170 Expiration: 3/812015 Supplement Card Boston,MA 02116 SOLAR CITY CORPORATION ASTRID BLANCO 24 ST MARTIN STREET BLD 2UNI WI-BOROUGH,MA 01752 144 Undersecretary Not valid without signature ` r DocuSign Envelope ID:F53B417E-3349-4E43-ADA7-101C82lD6A68 ecNr ■ ,SolarCity. Power Purchase Agreement d�a Here are the key terms of your SolarCity Power Purchase Agreement Date: 9/3/2014 O 12m000 2 System installation cost Electricity rate per kWh Agreement term Our Promises to You • We insure,maintain,and repair the System(including the inverter)at no additional cost to you,as specified in the agreement • We provide 24/7 web-enabled monitoring at no additional cost to you, as specified in the agreement. • We warranty your roof against leaks and restore your roof at the end of the agreement,as specified in the agreement. • The rate you pay for electricity, exclusive of taxes,will never increase by more than 2.90%per year. • The pricing in this PPA is valid for 30 days after 9/2/2014. • We are confident that we deliver excellent value and customer service.AS A RESULT,YOU ARE FREE TO CANCEL ANYTIME AT NO CHARGE PRIOR TO CONSTRUCTION ON YOUR HOME. Estimated First Year Production 8,593 kWh Customer's Name & Service Address Exactly as it appears on the utility bill Customer Name and Address Customer Name Installation Location Christopher P Derby 26 Dartmouth St 26 Dartmouth St North Andover, MA 01845 North Andover, MA 01845 Options for System purchase and transfer: Options at the end of the 20 year term: • If you move,you may transfer this agreement to the purchaser of your • SolarCity will remove the System at no cost to you. Home,as specified in the agreement. • You can upgrade to a new System with the latest solar * At certain times,as specified in the agreement,you may purchase the technology under a new contract. System. . You may purchase the System from SolarCity for its fair • These options apply during the 20 year term of our agreement and not market value as specified in the agreement. beyond that term. • You may renew this agreement for up to ten(10)years in two(2)five(5)year increments. 3055 CLEARVIEW WAY, SAN MATEO, CA 94402 888.SOL.CITY 1888.765.2489 I SOLARCITY.COM MA HIC 168572/MA Lic. MR-1136 Document Generated on 9/2/2014 247364 DocuSign Envelope ID:F53B417E-3349-4E43-ADA7-101C821D6A68 22.NOTICE OF RIGHT TO CANCEL. I have read this Power Purchase Agreement and the Exhibits in their YOU MAY CANCEL THIS CONTRACT AT ANY TIME PRIOR TO entirety and I acknowledge that I have received a complete copy of this MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE DATE Power Purchase Agreement. YOU SIGN THIS CONTRACT. SEE EXHIBIT 1,THE ATTACHED NOTICE OF CANCELLATION FORM FOR AN Customer's Name:Christopher P Derby EXPLANATION OF THIS RIGHT. Docuft ed by: 23.ADDITIONAL RIGHTS TO CANCEL. (,66 P � y IN ADDITION TO ANY RIGHTS YOU MAY HAVE TO CANCEL Signature: THIS PPA UNDER SECTION 22,YOU MAY ALSO CANCEL THIS PPA AT NO COST AT ANY TIME PRIOR TO Date: 9/3/2014 COMMENCEMENT OF CONSTRUCTION ON YOUR HOME. 24.Pricing The pricing in this PPA is valid for 30 days after 9/2/2014. If you don't sign this PPA and return it to us on or prior to 30 days after Customer's Name: 9/2/2014,SolarCity reserves the right to reject this PPA unless you agree to our then current pricing. Signature: Date: vi,isolarCity. Power Purchase Agreement SOLARCITY APPROVED Signature: UNDON RIVE. CEO (PPA) Power Purchase Agreement 410WIf My. Date: 9/2/2014 Solar Power Purchase Agreement version 8.0.2 247364 Qd�eD Version#39.1 1Te , So1arG o� l° -jHoF 3055 Clearview Way, San 'Mateo, CA 94402 �� Y00 AN (888)-SOL-CITY (765-2489) 1 www.solarcity.com K October 1, 2014 No.4 Project/Job # 0181013 RE: CERTIFICATION LETTER AL Project: Derby Residence DI itall SI n Yoo Jin Kim 26 Dartmouth St g g y North Andover, MA 01845 Date: 2014.10.0108:21:05 To Whom It May Concern, 07'00' A jobsite survey of the existing framing system was performed by a site survey team from SolarCity. Structural review was based on site observations and the design criteria listed below: Design Criteria: -Applicable Codes = MA Res. Code, 8th Edition,ASCE 7-05,and 2005 NDS - Risk Category = II -Wind Speed = 100 mph, Exposure Category C -Ground Snow Load = 50 psf - MPI: Roof DL = 11 psf, Roof LL/SL = 28 psf(Non-PV Areas), Roof LL/SL = 17.5 psf(PV Areas) Note: Per IBC 1613.1; Seismic check is not required because Ss= 0.33365 < 0.4g and Seismic Design Category(SDC) = C < D On the above referenced project,the components of the structural roof framing impacted by the installation of the PV assembly have been reviewed. After this review it has been determined that the existing structure is adequate to withstand the applicable roof dead load, PV assembly load,and live/snow loads indicated in the design criteria above. I certify that the structural roof framing and the new attachments that directly support the gravity loading and wind uplift loading from PV modules have been reviewed and determined to meet or exceed structural strength requirements of the MA Res. Code, 8th Edition. Please contact me with any questions or concerns regarding this project. Sincerely, Yoo]in Kim, P.E. Civil Engineer Main: 888.765.2489,x5743 email: ykim@solarcity.com 3055 Clearview Way San Mateo,CA 94402 T(650)638-1028 (888)SOL-CITY F(650)638-1029 solarcity.com A! :adz'1 L4("Ll ay1"V r N ' - !' L tb. (110146t- r ,1,1714,0 t •!y n,. MAt1"-1ti1'S1J !r'C'fi�.i - ,'", PL. IAVr c11 1 I,'j4" F `4 '. {{;^rl;_WA c:. , "'A ANI'111N)7 )':01:1�_. r K A 10.01.2014 SleekMountTM PV System Version#39.1 �o":SolarClt . y Structural Design Software PR03ECT INFORMATION &TABLE OF CONTENTS Project Name: Derby Residence AHJ: North Andover Job Number: 0181013 Building Code: MA Res. Code, 8th Edition Customer Name: Derby,Christopher Based On: IRC 2009/IBC 2009 Address: 26 Dartmouth St ASCE Code: ASCE 7-05 City/State: North Andover, MA Risk Category: II Zip Code 01845 Upgrades Req'd? No Latitude/Longitude: 42.677647 -71.130395 Stamp Req'd? Yes SC Office: Wilmington PV Designer: Todd Beachley Calculations: Brad Taylor EOR: Yoo Jin Kim P.E. Certification Letter 1 Project Information, Table Of Contents, &Vicinity Map 2 Structure Analysis (Loading Summary and Member Check) 3 Hardware Design (PV System Assembly) 4 Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.33365 < 0.4g and Seismic Design Category(SDC) = C < D 112-MILE VICINITY MAP 114 114 133 �D)i i e, MassGIS, Commonwealth of Massachus/etts EOEA, U S- DA Farm Service Agency 125 26 Dartmouth St, North Andover, MA 01845 Latitude:42.677647,Longitude: -71.130395,Exposure Category: C M LOAD ITEMIZATION - MP1 PV System Load PV Module Weight(psf) 2.5 psf Hardware Assembly Weight s 0.5 psf PV System Weight s 3.0 psf Roof Dead Load Material Load Roof Category Description MP1 Roofing Type Comp Roof ( 1 Layers) 2.5 psf Re-Roof to 1 Layer of Comp? No Underlayment Roofing Paper 0.5 psf Plywood Sheathing Yes 1.5 psf Board Sheathing None Rafter Size and Spacing 2 x 6 @ 16 in. O.C. 1.7 psf Vaulted Ceiling Yes 4.7 psf Miscellaneous Miscellaneous Items 0.1 sf Total Roof Dead Load 11 Psf(Mpi) 11.0 sf Reduced Roof LL Non-PV Areas Value ASCE 7-05 Roof Live Load Lo 20.0 psf Table 4-1 Member Tributary Area At < 200 sf Roof Slope 10/12 Tributary Area Reduction Rl 1 Section 4.9 Sloped Roof Reduction Rz 0.725 Section 4.9 Reduced Roof Live Load Lr Lf= Lo(Rt)(RA E uation 4-2 Reduced Roof Live Load Lr 14.5 psf(MP1) 14.5 psf Reduced Ground/Roof Live/Snow Loads Code Ground Snow Load py 50.0 psf ASCE Table 7-1 Snow Load Reductions Allowed? Yes Effective Roof Slope 380 Horiz. Distance from Eve to Ridge W 18.6 ft Snow Importance Factor IS 1.0 Table 1.5-2 Snow Exposure Factor Ce Partially Exposed Table 7-2 1.0 Snow Thermal Factor Ct All structures except as indicated otherwise Table 7-3 Minimum Flat Roof Snow Load (w/ 1.0 Rain-on-Snow Surcharge) Pf-min 35.0 psf 7.3.4&7.10 Flat Roof Snow Load Pf pf= 0.7(Ce) (Ct)(I) Pg; Pf? pf-min Eq: 7.3-1 35.0 psf 1 700/a ASCE Design Sloped Roof Snow Load Over Surroundinq Roof Surface Condition of Surrounding All Other Surfaces Roof CS-roof Figure 7-2 0.8 Design Roof Snow Load Over P:-roof= (CS_,. 0 Pf ASCE Eq: 7.4-1 Surroundin Roof Ps-roof 28.0 psf 56% ASCE Design Sloped Roof Snow Load Over PV Modules Surface Condition of PV ModulesUnobstructed Slippery Surfaces P° 0.5 Figure 7-2 Design Snow Load Over PV Ps-p„= (Cs- „)Pf ASCE Eq: 7.4-1 Modules PS-PV 17.3 psf 35% Woodworks® COMPANY PROJECT SOFFWARf FOS WOOD OFSICN Oct. 1, 2014 08:08 MP1.wwb Design Check Calculation Sheet WoodWorks Sizer 10.1 Loads: Load Type Distribution Pat- Location [ft] Magnitude Unit tern Start End Start End DL Dead Full Area No 11.00 (16.0) * psf PV LOAD Dead Partial Area No 0.83 13 .75 3 .00 (16.0) * psf ROOF SL 1 Snow Partial Area Yes 0.00 0.83 28.00 (16.0) * psf ROOF SL 2 Snow Partial Area Yes 13 .75 14.58 28.00 (16.0) * psf PV SL lSnow IPartial Areal Yesl 0.83 13 .75 1 17.30 (16.0) * sf *Tributary Width (in) Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) 0' 1'-9" 14'-7" Unfactored: Dead 195 154 Snow 203 158 Factored: Total 398 313 Bearing: F'theta 599 599 Capacity Joist 3480 3143 Supports 2789 - Anal/Des Joist 0.11 0.10 Support 0.14 - Load comb #2 #4 Length 3 .50 3 .50 Min req'd 0.50* 0.50* Cb 1.11 1.00 Cb min 1.75 1.00 Cb support 1.25 - Fcp sup 425, - *Minimum bearing length setting used: 1/2"for end supports Bearing for wall supports is perpendicular-to-grain bearing on top plate. No stud design included. MP1 Lumber-soft, S-P-F, No.1/No.2, 2x6 (1-1/2"x5-1/2") Supports: 1 - Lumber Stud Wall, S-P-F Stud; 2 - Hanger; Roof joist spaced at 16.0" c/c; Total length: 19'-8.6"; Pitch: 10/12; Lateral support: top= full, bottom= at supports; Repetitive factor: applied where permitted (refer to online help); WARNING: Member length exceeds typical stock length of 18.0[ft] WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN MP1.wwb WoodWorks®Sizer 10.1 Page 2 Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2012 : Criterion Analysis Value Design Value Analysis/Design Shear fv = 40 Fv' = 155 fv/Fv' = 0.26 Bending(+) fb = 1505 Fb' = 1504 fb/Fb' = 1.00 Bending(-) fb = 131 Fb' = 779 fb/Fb' = 0.17 Live Defl'n 0.80 = L/251 1.11 = L/180 0.72 Total Defl'n 1.63 = L/123 1 1.67 = L/120 0.97 Additional Data: FACTORS: F/E(psi)CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC# Fv' 135 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 2 Fb'+ 875 1.15 1.00 1.00 1.000 1.300 1.00 1.15 1.00 1.00 - 4 Fb' - 875 1.15 1.00 1.00 0.518 1.300 1.00 1.15 1.00 1.00 - 2 Fcp' 425 - 1.00 1.00 - - - - 1.00 1.00 - - E' 1.4 million 1.00 1.00 - - - - 1.00 1.00 - 4 Emin' 0.51 million 1.00 1.00 - - - - 1.00 1.00 - 4 CRITICAL LOAD COMBINATIONS: Shear : LC #2 = D+S, V = 239, V design = 222 lbs Bending(+) : LC #4 = D+S (pattern: sS) , M = 948 lbs-ft Bending(-) : LC #2 = D+S, M = 83 lbs-ft Deflection: LC #4 = (live) LC #4 = (total) D=dead L=construction S=snow W=wind I=impact Lr=roof constr. Lc=concentrated All LC's are listed in the Analysis output Load Patterns: s=S/2, X=L+S or L+Lr, _=no pattern load. in this span Load combinations: ASCE 7-10 / IBC 2012 CALCULATIONS: Deflection: EI = 29e06 lb-in2 "Live" deflection = Deflection from all non-dead loads (live, wind, snow...) Total Deflection = 1.00 (Dead Load Deflection) + Live Load Deflection. Bearing: Allowable bearing at an angle F'theta calculated for each support as per NDS 3 .10.3 Design Notes: 1. WoodWorks analysis and design are in accordance with the ICC International Building Code (IBC 2012), the National Design Specification (NDS 2012), and NDS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Continuous or Cantilevered Beams: NDS Clause 4.2.5.5 requires that normal grading provisions be extended to the middle 2/3 of 2 span beams and to the full length of cantilevers and other spans. 4. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. 5. SLOPED BEAMS: level bearing is required for all sloped beams. 6. The critical deflection value has been determined using maximum back-span deflection. Cantilever deflections do not govern design. CALCULATION OF DESIGN WIND LOADS - MPI Mounting Plane Information Roofing Material Comp Roof PV System Type SolarCity SleekMountTM Spanning Vents No Standoff Attachment Hardware Comp Mount Tyge C Roof Slope 380 Rafter Spacing 16"O.C. Framin Tvpe Direction Y-Y Rafters Purlin Spacing X-X Purlins Only NA Tile Reveal Tile Roofs Only NA Tile Attachment System Tile Roofs Only NA IStanding Seam Spacing SM Seam Only NA Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 100 mph Fig. 6-1 Exposure Category C Section 6.5.6.3 Roof Style Gable Roof Fig.6-11B/C/D-14A/B Mean Roof Height h 25 ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.95 Table 6-3 Topographic Factor KA 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Im ortance Factor I 1.0 Table 6-1 VelocityPressure qh = 0.00256(Kz)(Kzt)(Kd)(V^2)(I) qh 20.6 sf Equation 6-15 Wind Pressure Ext. Pressure Coefficient U GC -0.95 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient Down GC 0.88 Fig.6-11B/C/D-14A/B Design Wind Pressure p p = qh(GC ) Equation 6-22 Wind Pressure U -19.6 psf Wind Pressure Down 18.0 Psf ,ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 64" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 17 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T-actual -312 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 62.4% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 48" 64" Max Allowable Cantilever Portrait 20" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 21 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T-actual -391 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 78.1% ` ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONIC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. 1 CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING P01 POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 THREE LINE DIAGRAM LICENSE GENERAL NOTES Cutsheets Attached GEN #168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION ELEC 1136 MR OF THE MA STATE BUILDING CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: ZEP SOLAR 114 AHJ: North Andover REV BY DATE COMMENTS REV A NAME DATE COMMENTS * * r s UTILITY: National Grid USA (Massachusetts Electric) i 133 jiliEnds PREMISE OWNER: DESCRIPTION: DESIGN: CONFlDENIIAL— THE INFORMATION HEREIN JOB NUMBER: J B-0181013 0 0 ■ BENEFIT O SHALL NOTE USED FOR THE DERBY, CHRISTOPHER DERBY RESIDENCE Todd Beachley ';;;SO�arC�t�/. BENEFIT Of ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ��: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 26 DARTMOUTH ST 6.885 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS Moou�Es NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION NTH , 24 St. Martin Drive, Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (27) CANADIAN SOLAR # CS6P-255PXT; REV PATE; Marlborough, MA 01752 SOLARGIY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: T: (650) 636-1026 F: (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE5000A—USOOOSNR2 (978) 360-7012 COVER SHEET PV 1 10/1/2014 (BBB)-SOL-CITY(765-2489) www.solarcitycom PITCH: 38 ARRAY PITCH:38 MP1 AZIMUTH: 145 ARRAY AZIMUTH: 145 MATERIAL: Comp Shingle STORY: 2 Stories �N OF YOQ AN yn Z-17K No.4 AL. Digitally oo Jin Kim Date: 2014.10.01 08:21:59 -07'00' LEGEND (E) UTILITY METER & WARNING LABEL Inv INVERTER W/ INTEGRATED DC DISCO Inv & WARNING LABELS DC DISCONNECT & WARNING LABELS AC © © AC DISCONNECT & WARNING LABELS AC . DC JUNCTION/COMBINER BOX & LABELS FEE Mph,D; M DISTRIBUTION PANEL & LABELS O Lc LOAD CENTER & WARNING LABELS A O DEDICATED PV SYSTEM METER Q STANDOFF LOCATIONS Front Of HouseCONDUIT RUN ON EXTERIOR --- CONDUIT RUN ON INTERIOR GATE/FENCE Q HEAT PRODUCING VENTS ARE RED INTERIOR EQUIPMENT IS DASHED L---J SITE PLAN Scale: 1/8" = V O 1' 8' 16' S F JB-01 81013 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED AL THE INFORMATION HEREIN ore NUMBER: DERBY, CHRISTOPHER DERBY RESIDENCE Todd Beachle CONTAINED SHALL NOT E USED FOR THE y SolarCit BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �.��a NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 26 DARTMOUTH ST 6.885 KW PV ARRAY A • PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES: NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION NTH 24 St. Martin Drive, Building 2 Unit 11 THE SALE AND USE OF THE RESPECTIVE (27) CANADIAN SOLAR # CS6P-255PX PAGE NAME SHEET: REV DAIS Marlborough, MA ing Z SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T: (650)638 Marlborough, F: (650)638-1029 PERMf�SION of SOLARCITY INC. SOLAREDGE SE5000A—USOOOSNR2 (978) 360-7012 SITE PLAN PV 2 10/1/2014 (888)-SOL-CITY(765-2489) www.solarcitycom PV MODULE (E) 2x4 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE j ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT i ZEP ARRAY SKIRT (6) HOLE. (4) G(2) SEAL PILOT HOLE WITH POLY ZEP COMP MOUNT C URETHANE SEALANT. S1 ZEP FLASHING C (3) (3) INSERT FLASHING. (E) COMP. SHINGLE (1) (4) PLACE MOUNT. 4 -10' (E) LBW (E) ROOF DECKING (2) INSTALL LAG BOLT WITH SIDE VIEW OF MP1 NTs 5/16" DIA STAINLESS (5) (5) SEALING WASHER. A STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULESINSTALL LEVELING FOOT WITH WITH SEALING WASHER (6) BOLT & WASHERS. MPJ I X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES (2-1/2" EMBED, MIN) LANDSCAPE 64" 24" STAGGERED PORTRAIT 4s° zo° (E) RAFTER RAFTER 2X6 @ 16"OC ROOF AZI 145 PITCH 38 STORIES:2 STA N DO F F ARRAY AZI 145 PITCH 38 C.I. 2x4 @16"OC Comp Shingle 1 n OF Scale: 1 1/2 = 1 Y00 J ¢_ No.4 M. Digitally oo Jin Kim Date:2014.10.01 08:21:53 -07'00' CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: JB-01 81013 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: \� ■ CONTAINED SHALL NOT EXCEPT USED FOR THE Todd Beachle I1`SolarCity. DERBY, CHRISTOPHER DERBY RESIDENCE y NOR SHALL IBENEFIT OF ITBENDISCLDN WHRCITY OLE ORCIN MOUNTING SYSTEM: 26 DARTMOUTH ST 6.885 KW PV ARRAY , PART TO OTHERS OUTSIDE THE RECIPIENTS Comp Mount Type C ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: NORTH ANDOVER, MA 01845 24 St. Matin Drive, Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (27) CANADIAN SOLAR # CS6P-255PX SHEET: REV.: DATE: Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVPAGE NAME T. (650)638-1026 F- (650)636-1029 INVERTER:PERMISSION OF SOLARCITY INC. SOLA GE SE5000A—USOOOSNR2 (978) 360-7012 STRUCTURAL VIEWS PV 3 10/1/2014 (888)-SCI-CITY(765-2489) www.solarcity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO TWO (N) GROUND Panel Number: G303OB1100CU Inv 1: DC Ungrounded INV 1 -(1)SOLAREDGE#SE5000A-USOOOSNR LABEL: A -(27)CANADIAN SOLAR CS6P-255PX GEN #168572 ODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:12807471 Tie-In: Supply Side Connection Inverter; 50 OW, 240V, 97.5%; w/Unifed Disco and ZB,RGM,AFCI PV Module; 255W#234.3W PTC, Black Frame, MC4, ZEP Enabled ELEC 1136 MR Overhead Service Entrance INV 2 Voc: 37.4 Vpmax: 30.2 INV 3 1 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 150A MAIN SERVICE PANEL E 10OA/2P MAIN CIRCUIT BREAKER (E) WIRING CUTLER-HAMMER Inverter 1 Disconnect CUTLER-HAMMER 100A 2P 5 Disconnect 4 SOLAREDGE SE5000A-USOOOSNR2 B 30A C ZDV SolarCity 2 A L1 1 - - - LL 9 N 3 A Dc- MP 1: 1x13 GND - ---- GND ------------------------- - EGCI --- OC+ DC+ MP 1: 1x14 - - I -- - I DI GEC �N DG DC- I f-----J GND -- EGC--------------------------- -- '---- --- EGC -- J I TO MSP N I I I p I Z Z I � I GEC I TO 120, )V I I SINGLE PHASE I I I I UTILITY SERVICE I I I I I I MAIN BREAKER I I I PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Voc* = MAX VOC AT MIN TEMP ppI (2)Ground Rod; 5/8' x 8% Copper B (1)CUTLER-HAMMER N DG222NRB /tr� A (1)SolarCit #4 STRING JUNCTION BOX D� -(2)ILSCO f IPC 4/0-/6 Disconnect; 60A, 24OVac, Fusible, NEMA 3R /y 2x2 S MGS, UNFUSED, GROUNDED Insula ion Piercing Connector; Main 4/0-4, Tap 6-14 S C (1)CUTLER-HAMMER DG221UR6 PV (27)SOLAREDGE300-2NA4AZS SUPPLY SIDE CONNECTION. DISCONNECTING MEANS SHALL BE SUITABLE Disconnect; 30A, 24OVac, Non-Fusible, NEMA 3R PowerBox Optimizer, 30OW, H4, DC to DC, ZEP AS SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. -(1)CUTLER-HAMMER !DG030NB Ground/Neutral Kit; 30A, General Duty(DG) nd (1)AWG /6, Solid Bare Copper -(1)Ground Rod; 5/8' x W, Copper (N) ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION NO. 2, ADDITIONAL ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE O� 1 AWG#6, THWN-2, Black � 1 AWG 110, THWN-2, Black 1 AWG #8, THWN-2, Black Voc* =500 VDC Isc =30 ADC 2 AWG /10, PV WIRE, Black Voc* =500 VDC Isc =15 ADC Iu+F(1)AWG/6, THWN-2, Red ®Ist (1)AWG #10, THWN-2, Red O (1)AWG #8, THWN-2, Red Vmp =350 VDC Imp=19.42 ADC O (1)AWG #6, Solid Bare Copper EGC Vmp =350 VDC Imp=9.35 ADC IL�-LL(I)AWG/6, THWN-2, White NEUTRAL Vmp =240 VAC Imp=20.83AAC LL LL(1)AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=20.83AAC EGC. . . -(1)Conduit.Kit;,3/4' EMT. . . . . . . . . . . . . . . . . . * . . . . . . . . . . . . . . . . . . . . . . . 70)AWG }6,.Solid Bare.Copper. GEC_ . _ -(1)Conduit.Kit;.3/4'.EMT. . . . . . . . . . . . . . . . .-0 AWG #8,.TH.WN-2,.Green . , EGC/GEC.-(1)Conduit_Kit;.3. _EMT. (2 AWG #10, PV WIRE, Black 500 VDC Isc =' '15' . . . ADC O 9 (1)AWG #6, Solid Bare Copper EGC Vmp =350 VDC Imp=10.07 ADC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: JB-0181013 00 PREMISE OWNER: DESCRIPTION: DESIGN: DERBY, CHRISTOPHER Todd Beachle • CONTAINED SHALL NOT E USED FOR THE DERBY RESIDENCE y ��;SO�a�C�ty. BENEFIT OF ANYONE EXCEPT SOLARGTY INC., MOUNTING SYSTEM: �.�� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 26 DARTMOUTH ST 6.885 KW PV ARRAY PART TO OTHERS OUTSIDE THE CONNECTION WITH MODULES: NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION IMTH � THE SALE AND USE OF THE RESPECTIVE (27) CANADIAN SOLAR # CS6P-255PX 24 St. Martin Drive, Building 2, Unit 11 SOLARGTY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE L (650) 638-1028 F:A(61752 638-1029 PERMIS$ION of soI1,RGTY INC. SOLAREDGE SE5000A-USOOOSNR2 (978) 360-7012 THREE LINE DIAGRAM PV 4 10/1/2014 (668)-SOL-CITY(765-2489) www.solarcity.com Label Location: abel Location: WARNI�IG:`PHOTOVOLTAIG POWER SOURCE Label • • 4$ 4 'W/ RfNI'INGr WARNING ' Per Code: Code: Per Code: NEC EL'EGTRiGSI�OCZ IiAZARD ELECTRIC SHOCK HAZARD 690.31.G.3 D9"NOT�TQ�UCH TERMINALS NEC � � - THE.DC CONDUCTORS OF THIS 690.35(F) Label • •n: TO BE LOAD;SIDES;MAY BEIN ERGIZED UNGROUNDED AND PHOTOVOLTAIC DC � ••- IN THE OPEN ION MAYBE ENERGIZED UNGROUNDED NEC..DISCONNECTINVERTERIS - - -- 690.14.C.2 Label Location: Label Location: 1/1/ARN LN G Code: MAXIMUM POWER-_ - POINT CURRENT(Imp} A _ _ INVERTER OUTPUT MAXIMUM POWER- •• CONNECTION • POINT VOLTAGE(Vmp}_V 690.53 DO NOT RELOCATE - THIS OVERCURRENT MAXIMUM SYSTEM V DEVICE VOLTAGE(Voc)_ ` SHORT-CIRCUIT A CURRENT(Isc)_ PHOTOVOLTAIC POINT OF (POI) Label • _ • INTERCONNECTIONPer • _ WARNING: ELECTRIC SHOCK WARNING - HAZARD. DO NOT TOUNEC 690.17.4; NEC 690.54 CH Per Code: TERMINALS,TERMINALS ON ELECTRICAL SHOCK HAZARD 690.17(4) BO7Fi THE LINE AND LOAD SIDE DO NOT TOUCH TERMINALSMAY BE ENERGIZED IN THE OPEN TERMINALS ON BOTH LINE AND POSITION. FOR SERVICE LOAD SIDES MAY BE ENERGIZED DE-ENERGIZE BOTH SOURCE "IN THE OPEN POSITION AND MAIN BREAKER. DC VOLTAGE IS PV POWER SOURCE ALWAYS PRESENT WHEN MAXIMUM AC SOLAR MODULES ARE OPERATING CURRENT A EXPOSED TO SUNLIGHT MAXIMUM AC OPERATING VOLTAGE V Label • • WARNINGLocation: Per ELECTRIC SHOCK HAZARD 690.5(C) CAUTION ' (POI)_ IF A GROUND FAULT IS INDICATEDPHOTOVOLTAIC SYSTEM NORMALLY GROUNDEDNEC 690.64.13.4 CONDUCTORS MAY BE CIRCUIT IS BACKFED Label • • Label • - CAUTION '• PHOTOVOLTAIC AC A • ) Per Code: Per Code: PHOTOVOLTAOICSYSTEM 690.64.B.4 (C): Cond •0644 • uit NEC •.0 :. Conduit(D): Distribution Panel (DC): DC Disconnect (IC): Interior Run InverterLabel Location: (INV): - ct AC A -OI) (LC): Load Center OPERATING CURRENTPer Code: Meter(M): Utility MAXIMUM AC VNEC •• • Point of • • OPERATING VOLTAGE _ ■mn■ nuw■—■-- m ■ow■iu• ■uuin■ a' SC umnnnimuumm ■iuuuuu■uuunuuu ' unnmc• 14 I nunnunmuiuuuill millinnr■w■ SolarCity SleekMountTM - Comp SolarCity SleekMountTM - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM modules --''"r aesthetics while minimizing roof disruption and iO Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and • Interlock and grounding devices in system UL `listed to UL 2703 Fastener Size Per NDS Section 1.1.3.2 mounting clamps, combined with the addition of array trim and a lower profile all contribute • Interlock and Ground Zep ETL listed to UL 1703 Seal pilot hole with roofing sealant as"Grounding and Bonding System" .; 3 Insert Com Mount flashing under upper to a more visually appealing system.SleekMount Q p 9 pp utilizes Zep Compatible TM modules with •Ground Zep UL and ETL listed to UL 467 as layer of shingle strengthened frames that attach directly to grounding device Place Comp Mount centered Zep Solar standoffs, effectively eliminating the ® need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition Install lag pursuant to NDS Section 11.1.3 •Anodized components for corrosion resistance shingles are not required to be cut for this \ with sealing washer. system, allowing for minimal roof disturbance. •Applicable for vent spanning functions © Secure Leveling Foot to the Comp Mount using machine Screw O7 Place module ® Components { O ® 5/16"Machine Screw B ® Leveling Foot QLag Screw ✓ © Comp Mount O Comp Mount Flashing IWO -.; SolarCity �A'0 0� 9 ':����SolarCity ® January 2013 LISTED �►t ��MPPT ® January 2013 J e�Ed?ees,.� 400i Electrical Data CS6P-235/240/245/250/255PX N <°a\, _r CanadianSolar Black framed e�eak�ti STC CS6P-235P CS6P-240P CS6P-245P CS6P.250PXCS6P-255PX Temperature Characteristics Nominal Maximum Power (Pmax) 235W 240W 245W 250W 255W Optimum Operating Voltage(Vmp) 29.8V 29.9V 30.OV 30.1V 30.2V Pmax -0.43 rC NewEdge Optimum Operating Current(Imp) 7.90A 8.03A 8.17A 8.30A 8.43A Temperature Coefficient Voc -0.34%rC Open Circuit Voltage(Voc) 36.9V 37.OV 37.1V 37.2v 37AV Isc 10.065%rc Black-framed Short Circuit Current(Isc) 8.46A 8.59A 8.74A 8.87A 9.00A Normal Operating Cell Temperature 45±2°C • Module Efficiency 14.61% 14.92% 15.23% 15.54% 15.85% Operating Temperature -40•C-+85°C Performance at Low Irradiance ■ Maximum System Voltage 1000V IEC /600v UL Industry leading performance at low irradiation Maximum Series Fuse Rating 15A environment,+95.5%module efficiency from an Application Classification ClassA irradiance of 1000w/m'to 200w/m' Next Generation Solar Module Power Tolerance 0-+5W, (AM 1.5,25°C) Under Standard Test Conditions(STC)of irradiance of 1000W/m',spectrum AM 1.5 and cell temperature of 25•C NewEdge,the next generation module designed for multiple Engineering Drawings types of mounting systems,offers customers the added NOCT _. CS6P-235PX CS6P-240PX CS6P-245PX CS6P-250PX CS6P-255PX Nominal Maximum Power (Pmax) 170W 174W 178W 181W 185W value of minimal system costs,aesthetic seamless Optimum Operating Voltage(Vmp) 27.2V 27.3V 27AV 27.5V 27.5V appearance,auto groundingand theft resistance. Optimum Operating Current(Imp) 6.27A 6.38A 6.49A 6.60A 6.71A Open Circuit Voltage(Voc) 33.9V 34.OV 34.1V 34.2V 34AV The black-framed CS6P-PX is a robust 60 cell solar module Short Circuit Current(Isc) 6.86A 6.96A 7.08A 7.19A 7.29A incorporating the groundbreaking Zep compatible frame. Linder Normal operating cell Temperature,Irradiance of 800 W/m',spectrum AM 1.5,ambient temperature 201C, The specially designed frame allows for rail-free fast wind speed 1 m/s installation with the industry's most reliable grounding Mechanical Data system.The module uses high efficiency poly-crystalline Cell Type Poly-crystalline 156 x 156mm,2 or 3 Busbars Key Features silicon cells laminated with a white back sheet and framed Cell Arrangement 60(6 x 10) with black anodized aluminum.The black-framed CS6P-PX Dimensions 1638 x 982 x 40mm(64.5 x 38.7 x 1.571n) • Quick and easy to install - dramatically is the perfect choice for customers who are looking for a high Weight 20.5kg(45.2 lbs) reduces installation time quality aesthetic module with lowest system cost. Front Cover 3.2mm Tempered glass Frame Material Anodized aluminium alloy • Lower system costs - can cut rooftop J-Box IP65,3 diodes installation costs in half Best Quality Cable 4mm'(IEC)/12AWG(UL),1000mm • 235 quality control points in module production connectors MC4 or MC4 Comparable � • Aesthetic seamless appearance - low profile • EL screening to eliminate product defects with auto leveling and alignment • Current binning to improve system performance Standard Packaging(Modules per Pallet) 24pcs Module Pieces per container(40 ft.Container) 672pcs(40'HQ) • Accredited Salt mist resistant • Built-in hyper-bonded grounding system - if it's I-V Curves (CS6P-255PX) mounted,it's grounded Best Warranty Insurance • Theft resistant hardware • 25 years worldwide coverage i 0 e 1 • 100/e warranty term coverage Section A-A • Ultra-low parts count - 3 parts for the mounting • Providing third party bankruptcy rights 35.0 and grounding system Non-cancellable Industry first comprehensive warranty insurance by Immediate coverage • AM Best rated leading insurance companies in the • Insured by 3 world top insurance companies ' ' world t { - +415 r1-at,_,_Comprehensive Certificates I - F 1 2 -= -• Industry leading plus only power tolerance:0 5W • IEC 61215,IEC 61730, IEC61701 ED2,UL1703, • Backward compatibility with all standard rooftop and CEC Listed,CE and MCS ground mounting systems • ISO9001:2008:Quality Management System R "" . ISO/TSI 6949:2009:The automotive quality Specifications included in this datasheel are subject to change without prior notice. • Backed By Our New 10/25 Linear Power Warranty management system Plus our added 25 year insurance coverage • IS014001:2004:Standards for Environmental About Canadian Solar management system Canadian Solar Inc. is one of the world's largest solar Canadian Solar was founded in Canada in 2001 and was 1 97% ed . QC080000 HSPM:The Certification for companies. As a leading vertically-integrated successfully listed on NASDAQ Exchange (symbol: CSIQ) in 97°/. Valu manufacturer of ingots,wafers,cells,solar modules and November 2006. Canadian Solar has module manufacturing dd 9g% a From Warranty Hazardous Substances Regulations solar systems, Canadian Solar delivers solar power capacity of 2.05GW and cell manufacturing capacity of 1.3GW. OHSAS 18001:2007 International standards for products of uncompromising quality to worldwide 80 occupational health and safety customers. Canadian Solar's world class team of 0% s 10 1s 20 zs • REACH Compliance professionals works closely with our customers to provide them with solutions for all their solar needs. Headquarters 1545 Speedvale Guelph I • . N 1 K 1 E6 I Canada • 10 year product warranty on materials and workmanship O YE espug�E C` S� .ve�yr,..r�o,: w* •25 year linear power output warranty 1881•837 0 www.canadiansolar.com EN-Rev 10.17 Copyright 0 2012 Canadian Solar Inc. solar=ee solar=ee T SolarEdge Power Optimizer Module Add-On for North America P300 / P350 / P400 SolarEdge Power Optimizer P300P350 P400 " Module Add-On For North America (for 60-ceP" (for PV (for 9a cell PV modules) P300 P350 P400 INPUT Rated Input DC Power"I �99�. 1 400 _W ............. e ................ ........ Vdc ,j�bsolute Maximum Input temperature). ... .....4�..............I....... 60 . ..................�R........... .... M .........*....Range............ ............... ....... ........ ...... .. Vdc ................................... ...... 48._..... 10 Adc Maximum DC Input Adc ....................................................I........................... ................... ............. ....... Maximum Efficiency ........................................ .........................................99.5...........................................%...... Weighted ......................................... ..........I......I.......................... ....................................... ............ Overvoltage Category III OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) ..Maximum Output Current 15 Adc Maximum Output Voltage 6 'e .......*........ ................................. 0utpu0...........................I.............Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE EMC . ................... ..........I....................... ......... ........... ....... Safety ..................................................................... ......... ... ................... ....... ...... RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed Vdc �n!eT YRI!�q�.................................. ...................................... .......................... ..... .... Dimensions(WxLx 1Hk............................................... .................... .................. . weight(including gr/Ib �0!es)................... . ...........................r.................. .................................... .................................... .. Input Connector ................................I.................................................. ........................... ............. Output Wire Type 0..gs. 3 Double Insulated;Amphenol ............................................. Output Wire Length ....................._.............................................9.......I................*......*1':'2'/*��­9'............ ........ Operating 'C/*� .. .. .................................. ............................. .......................................... ............. . Protection Ratin .............I.................................. ................................. .............................. ................ Relative Humidity .............................................................................................0.-..1.00..................................... .....%...... Rated 5T­If the module.-11 If.P II r5%M-WIM111 A— PV SYSTEM DESIGN USING A SOLAREDGE SINGLE PHASE THREE PHASE THREE PHASE INVERTER 208V 480V PV power optimization at the module-levelMinimum St'ing�Len!�h(Po a 10 1s .. _. ................................................ .............. wer Optimizers) Maximum String Length(Power 0 timiz rs) — Up to 25%more energy ..........................................p......e:..................................... ............ Maximum Power per String 5250 6 00 12750 .. - ( ) .......................................................................... .......... ............ Superior efficiency 99.5% .................... Parallel Strings of Different Len.. ngths or orientations Yes — Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading .................................... ................................................................................................................... — Flexible system design for maximum space utilization — Fast installation with a single bolt — Next generation maintenance with module-level monitoring — Module-level voltage shutdown for installer and firefighter safety USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us