Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Building Permit #361-15 - 31 OXBOW CIRCLE 10/16/2014
1 � f NORTH 1 BUILDING PERMIT ti-' or°.t"`°.^6.,'�'o r TOWN OF NORTH ANDOVER to APPLICATION FOR PLAN EXAMI Permit NO: !!``tt'' II �� Date ReceivedNATI T Arlo Date Issued: 101110 �9SS�cHUS t� MPORTANT: Applicant must complete all items on this page LOCATION 31 Oxbow Cir Print PROPERTY OWNER Judy Ferres Print MAP NO: 210 PARCEL: 107 ZONING DISTRICT: Historic District yesrn Machine Shop Village yes TYPE OF IMPROVEMENT PROPOSED USE Residential Non- Residential ❑ New Building ❑One family ❑Addition E]Two or more family ❑ Industrial ❑Alteration No. of units: ❑ Commercial ❑ Repair, replacement ❑ Assessory Bldg ❑ Others: El Demolition ❑✓Other Solar/PV ❑ Septic ❑ Well ❑ Floodplain ❑Wetlands ❑ Watershed District ❑Water/Sewer Install 68 solar electric panels @17.34kW DC to roof of existing home, to be interconnected with the homes' electrical system Identification Please Type or Print Clearly) OWNER: Name: Judy Ferres Phone: (978)688-8589 Address: 31 Oxbow Cir '* CONTRACTOR Name: Phone: 978-215-2360 SolarCity Corp '' Address: 800 Research Dr.Wilmington Ma.01887 Supervisor's Construction License: Exp. Date: 107663 8/29/2017 Home Improvement License: Exp. Date: 168572 3/8/2015 ARCHITECT/ENGINEER Phone: Address: Reg. No. FEE SCHEDULE:BULDING PERMIT:$12.00 PER$1000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PER S.F. Total Project Cost: $43,000 FEE: $ 1710 Check No.: 11 r�, Receipt No.: ct�. '3 ' NOTE: Persons contracting'with unregistered contractors do not have access to the guarantyfund ignature of Agent/Owner Signature of contractor C-e,c � -1 Plans Submitted ❑ Plans Waived ❑ Certified Plot Plan ❑ Stamped Plans ❑ TYPE'OF SEWERAGE DISPOSAL Public Sewer ❑ Tanning/Massage/Body Art ❑ Swimming Pools ❑ Well ❑ Tobacco Sales ❑ Food Packaging/Sales ❑ Private(septic tank,etc. ❑ Permanent Dumpster on Site ❑ THE FOLLOWING SECTIONS FOR OFFICE USE ONLY INTERDEPARTMENTAL SIGN OFF - U FORM PLANNING & DEVELOPMENT Reviewed On Signature_ COMMENTS CONSERVATION Reviewed on Signature COMMENTS HEALTH Reviewed on Siqnature COMMENTS 4 Zoning Board of Appeals: Variance, Petition No: Zoning Decision/receipt submitted yes Planning Board Decision: Comments Conservation Decision: Comments Water& Sewer Con nection/Siqnature& Date Driveway Permit DPW Town Engineer: Signature: Located 384 Osgood Street FIRE DEPARTMENT - Temp Dumpster on site yes no Located at 124 Main Street Fire Department signature/date COMMENTS ; Dimension Number of Stories: Total square feet of floor area, based on Exterior dimensions. Total land area, sq. ft.: ELECTRICAL: Movement of Meter location, mast or service drop requires approval of Electrical Inspector Yes No DANGER ZONE LITERATURE: Yes No MGL Chapter 166 Section 21A—F and G min.$100-$1000 fine NOTES and DATA— (For department use) ❑ Notified for pickup Call Email Date Time Contact Name Doc.Building Permit Revised 2014 Building Department The following is a list of the required forms to be filled out for the appropriate permit to be obtained. Roofing, Siding, Interior Rehabilitation Permits ❑ Building Permit Application ❑ Workers Comp Affidavit ❑ Photo Copy Of H.I.C. And/Or C.S.L. Licenses ❑ Copy of Contract ❑ Floor Plan Or Proposed Interior Work ❑ Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit Addition Or Decks ❑ Building Permit Application ❑ Certified Surveyed Plot Plan ❑ Workers Comp Affidavit ❑ Photo Copy of H.I.C. And C.S.L. Licenses ❑ Copy Of Contract ❑ Floor/Cross Section/Elevation Plan Of Proposed Work With Sprinkler Plan And Hydraulic Calculations (If Applicable) ❑ Mass check Energy Compliance Report (If Applicable) ❑ Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit New Construction (Single and Two Family) ❑ Building Permit Application ❑ Certified Proposed Plot Plan ❑ Photo of H.I.C. And C.S.L. Licenses ❑ Workers Comp Affidavit ❑ Two Sets of Building Plans (One To Be Returned) to Include Sprinkler Plan And Hydraulic Calculations (If Applicable) ❑ Copy of Contract ❑ Mass check Energy Compliance Report ❑ Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg. Permit In all cases if a variance or special permit was required the Town Clerks office must stamp the decision from the Board of Appeals that the appeal period is over. The applicant must then get this recorded at the Registry of Deeds. One copy and proof of recording must be submitted with the building application Doc:Building Permit Revised 2014 Location ' No. 7 Date 1 d ( '� 4 . - TOWN OF NORTH ANDOVER • ��.�LaED j�a` . • ra Certificate of Occupancy $ Building/Frame Permit Fee $ Foundation Permit Fee $ Other Permit Fee $ TOTAL $ Check# e 1 Q u Building Inspector t10RTH Town of _ � Andover No. �y * s, ' ;h ver, Mass, , I o � K. 1. COC NIC Ml WICK s V BOARD OF HEALTH Food/Kitchen PERMIT T LD Septic System aEft THIS CERTIFIES THAT ........N�. .. ....... le S........... ................................................. BUILDING INSPECTOR Foundation , �..... a►�c.6.6..w Com. ....... has permission toe ct .......................... buildings on ... .. .... ... .. .. .� ... Rough to be occupied as ...... ........ . .......... •..?5 .... Chimney provided that the person accepting this permit shall in of respect conform to the terms of the application p p p g p � p pp Final on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection, Alteration and Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR Rough VIOLATION of the Zoning or Building Regulations Voids this Permit. Final PERMIT EXPIRES IN 6 ONTHS ELECTRICAL INSPECTOR UNLESS CONSTRUC Rough Service ............. ..... ........ .......................................... Final BUILDING INSPECTOR GAS INSPECTOR Occupancy Permit Reguired to Occupy Building Rough Display in a Conspicuous Place on the Premises — Do Not Remove Final No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. Burner Street No. Smoke Det. Deems, Maura From: ��avid Millar <dmillar@solarcity.com> Sent: Tuesday, December 09, 2014 3:05 PM To: -Deems, Maura Subject: 31 Oxbow Cir Attachments: jb_0181110_00_c_acad_b_Ol.pdf North Andover Building Department, Attached are the recently revised plans for our solar installation @ 31 Oxbow Cir. Since receiving the Building permit (Building-361-15) we needed to downsize the system from the original plans by 18 panels, per the customer's request. (new total 49 panels @12.495).All modules were taken off MP4, Changes can be found clouded on PV2—Site Plan. We would greatly appreciate these plans be added as a modification to our existing permit. Please do not hesitate to contact me regarding this matter. Sincerely, Dave David Millar I Permit Coordinator I SolarCity I Wilmington, MA I T_978-215-23601 C:617-417-73121 dmillar solarcity.com www.solarcity.com SolarCity, HIC 168572/MA Lic.11 36M 1 Q a s ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED NA A AC ALTERNATING CURRENT UL—USIED POWER—CONDITIONING INVERTER. BLDG BUILDING 2 THIS SYSTEM HAS NO BATTERIES NO UPS CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL UST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART.110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART.690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT VALL BE IDENTIFIED BY HOG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART.210.5. I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART.250.97,250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART.690.31(E). MIN MINIMUM & ALL WIRES SHALL BE PROVIDED LOUTH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REWIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE W ON CENTER UL—USTEO LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE PV PHOTOVOLTAIC 10. MODULE FRAMES RAIL,AND POSTS SHALL BE SCH SCHEDULE BONDED WTH EQUIPMENT GROUND CONDUCTORS S STAINLESS STEEL STCSTANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Wap VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R,RAINTIGHT PVI COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES PV5 THREE LINE DIAGRAM Cutsheets Attached GEN/168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION ELEC 1136 MR OF THE MA STATE BUILDING CODE. 4k 2 ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE INCLUDING • • MASSACHUSETTS AMENDMENTS. 114 MODULE GROUNDING METHOD: ZEP SOLAR AH,}. North Andover A REV BY DATE COMMENTS UTILITY:National Grid USA(Massachusetts Electric) nE r•a�a^o J B-0181110 00 uw»'�ocM° m wnNc FERRIES, JUDY&JACK F�ERRES RESIDENCE �ia�ta Napgam - 50�8fC�}" Nm suu n m sanosa N wmc w N camMutat Type C 31 OXBOW CIR 12.495 KW PV ARRAY rr•T To o�wa ansa nc�rs vNe�e NORTH ANDOVER, MA 01845 4T.INU11at E]OtPT N @MCIOI Nnl nc sva No use a Nwxmc 49 CANADIAN SOLAR I CS6P-255PX N A•.m oAu B►fo 1 ua ii 5f fir• DE NlTIFM �� Na NVE 9EFe IE1G are ®`u3Si�'® Multiple Inverters 9786888589 COVER SHEET PV 1 c 11/13/2014 9 r a PITCH:35 ARRAY PITCH:35 MPI ADMUTH:303 ARRAY AZIMUTH:103 n ti MATERIAL'Com Shin le STORY:2 Stones i' PITCH:35 ARRAY PITCH:35 ""— MP2 AZIMUTH:283 ARRAY AZIMUTH:283 _ MATERIAL*Com Shin le STORY:2 Stones PITCH:35 ARRAY PITCH:35 MP3 AZIMUTH:110 AZIMUTH: 0 MATERIAL:Com ARRAY AZ13 Shin le STORY:2 Stones PITCH:35 ARRAY PITCH:35 C MP4 AZIMUTH:290 ARRAY AZIMUTH:290 MATERIAL•Com Shin le STORY:2 Stones D 3 LEGEND ® s (E)U11UTY METER A:WARNING LABEL ^' O INVERTER W/INTEGRATED OC DISCO »� ✓p WARNING LABELS p DC DISCONNECT h WARNING LABELS B � O AC DISCONNECT&WARNING LABELS A Q DC JUNCTION/COMBINER BOX&LABELS Digitally ooJinKim Frorrc of House Date:2 4.11.13 09:11:12 ❑O° DISTRIBUTION PANEL&LABELS -08'00' LOAD CENTER @ WARNING LABELS O DEDICATED PV SYSTEM METER (Q1 STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR GATE/FENCE • CAy T_ Q HEAT PRODUCING VENTS ARE RED �(D _ INTERIOR EQUIPMENT IS DASHED L® M JSITE PLAN N Inv Inv Scale:O 10' =1' E 01' 10' LC ORlfIXMTAI-MxFONAipn 1F%11 JB-0181110 00JUDY&JACK FERRES RESIDENCEa olv9 Nam WlIAI®9WL IIDi S U4D M iXe , "1 ®Eili Q AN1RE IXffPT SOLWtl1Y xC.. IC.,51510! M°11NLRff 0°a®N HOE°" Com Mount T e C 31 OXBOW CIR 12.495 KW PV ARRAY `s rAAr ro onus almc nmavlrs mcw5unm.E>�r n menclux■1x S ) NORTH ANDOVER, MA 01845 (49 �swt wo ux a nt n®ccmc 49 CANADIAN SOLAR I CS6P-255PX .334x+t1 saAAmr mwmlr.smwl nE nm>f �� rAn:nxc sur. 55r. are r.(a5o7��`n(mc1 nn-ion r5w55soxasaAxmrrc Multiple Inverters 9786888589 SITE PLAN PV 2 c 11/13/2014 Ieee>-aanPes ....a�aty� 4 (E)2.4 1x6 2x8 2.4 S S 4- 4LBW 4-f0' OW n SIDE VIEW OF MP2 rs n SIDE VIEW OF MPl m5 0 ~ 1 MP2vcvmtFreBT-5vpaxc v MPI axG lx � �x 64arvcxiAMI�6 24 siK46RED Wra6f.VE 64• 24� 6THGEPfO NxixNr 98" 28" 46' 26' BlJrFB 2x8 @ 16"OC Tey S:2 axFlfn b8 @ 16'OC pp�v nil iro Prta is SrpU6:2 2x18 016"00 shi k 2x10 @36'Oc ��1tlOFPV MODULE S1 ,t,FT 5/16'BOLT WTH LOCK INSTALLATION ORDER Ql' YOO JUN 1, FENDER WASHERS LOCATE RAFTER,MARK HOLE `2TS3 ZEP LEVELING FOOT (1) LOCATION,AND DRILL PILOT No. ZEP ARRAY SKIRT (6) HOLE. (4) (2) SEAL PILOT HOLE YATFi ZEP COMP MOUNT C POLYURETHANE SEALANT. Digitally o An Kim ZEP FLASHING C 3 (3) INSERT FLASHING. Date:20 4.11.13 09:11:05 E COMP.SHINGLE -08.00' () (1) (a) PLACE MouNT. (O LBW (E)ROOF DECKING (2) SIDE VIEW OF MP3 nfi 5/16-DIA STAINLESS (5) (5) INSTALL LAG ROLT W17H C STEEL LAG BOLT _ - WITH SEALING WASHER LOWEST MODULE SUBSEWENT MODULES (6 INSTALL LEVEIJNC F00T PATH MP3 wnu rxmevin T-senaxG vrarvmevcx arcs (2-1/2'EMBED,MIN) ) BOLT k WASHERS x 61' 29" AGGFvfD ro8mort 48• (E)RAFTER �x b6@16.00 x�T , %TGx 36 naw�:2 STANDOFF 0 %TCn 35 u. 2x8 @16' [`a J Sc.:1 1/2"=1' - ^^a J B-0181110 00 4wTw�m suu.T a usn ra 3� FERRES, JUDY&JACK ITI"W® � � FERRES RESIDENCE Lalita Nayvgam SolarCity. PWnmonw w3m6lfE rsuaWhwnt Te C 31 OXBOW CIR Comp M 12.495 KW PV ARRAY r BecW4una.txorrW wNCDnur 34ro Ymucs NORTH ANDOVER, MA 01845 IWiy� fx[sut WN us:v f�ieaccmc 49 CANADIAN SOLAR I CS6P-255PX 24 a u.0 o'M )u uxf n Pu a�d�7rWnart nc Wemx � r. we s¢r: av um c(ay 6�'W'ie-f'o `nu(my aarm Multiple Invertus 19786888589 STRUCTURAL VIEWS PV 3 c 11/13/2014 (sem-m-mTtias-:w1.•..mux�x f UPLIFT CALCULATIONS SEE SEPARATE PACKET FOR STRUCTURAL CALCULATIONS. JB-0181110 00 �, JUDY&JACK omaE "�1°901 M01 a 04D f0R"` FERRIES RESIDENCE lama N.y g- City. eamr s xxm[Exc[Pr sawwrc xc, wrn¢mmE Yn9am Maunt 7 e C 31 OXBOW CIR 12.495 KW PV ARRAY h� P"fE ro onmx wlm[,�IEaP[llt'S acxxEulnE Exavr"mon,n,r,x Ilmuu NORTH ANDOVER, MA 01845 iK wx u"usE a 1r¢a�Eomc 49 CANADIAN SOLAR CS6P-255PX 5"AIRm F➢Ix1VEML•TRAIL 111E NIIE" � P�KY[ 9RC IEY. DAIL T;( 6A-10}E f Im7 a1FfOM vuePma v Txrtmr PIG Mult'le Inverters 9786888589 UPLIFT CALCULATIONS PV 4 c fl/ll/X14 1 GROUND SPECS I MAIN PANEL SPECS I GENERAL NOTES INVERTER SPECS MODULE SPECS I LICENSE BOND N /B DEC TO TWO N (RWIaD an G40/OMBIZW Inr I:DC On RODS AT PANEL WITH TO, CU Meta Number:11807069 Inr 2 DC UngmDnded aIw. .A o -(49)CANAOINa SIXM CS6P-255P% CEN/168572 PV MDd 4 2d 274.3W PTC,Blade Frame,M04,ZEP Fn.Wed ELEC 1138 MR Undagand S.41.Ent— In:Supply SMe Connection INV 2-(1) z�.91$. �a�$�� Voc 37.4 VP-234 P— 30.2 INV 3 �Iac AND hp ARE SHOWN IN THE DC STRINGS IDENTnER JE200A MAIN SERVICE PANEL. E 2DOA SCAM CIRCUIT BREAKER CUTLER-HAMMER BflYANT Inverter 1 Sdor6ty I Dieecnneat CU DER-HHM (N)125A Load Center 9 � s A v _ 100A/7P B 60A SE50DOA-USD003TR2 ¢ C D �/� MP 3:1x8 eI. MIr--------- -- - ------- - Lpc--- ---------- ---a It m. s z _____________ _S M 'IIoJgK P 1:1x19 I an0 "5c_—_ _________ ------------ _ Sac______________ } •� Inverter 2 wawn m 3/4'PYI o SOLMED(EB 7 ra• I I i � SE6000A-USOWSIRI w MP 2:1.13 ' 35A/1P T 4 � I � II m,mn,aY � B � ] : PI ASE ec, L_ ___ —___________ _ __ p� MP 2:1x14 Uflatt SERVICE I � Amp' (Dawn Im J/Y On ii PHOTO VOLTAIC SYSTEM EQUIPPED'MIN RAPID SHUTDOWN Voc4=MAX VOC AT MIN TEMP 21—a Ree 5/C.9..Caper (1) / It) 4 Bp�{ I _X)L42 PD./p-� s °�m"rrtiv'�L% �W xou AC A 51�R uivdAq pE0 DC wAaUm IVwd°a.aim Mw 1]R1,rap a-,. -fa)IPanm DaoWm D (t)amAm/amlwlzm � I�t taoA p.�.a 4nr(oLi PV W9 a,,V1A� Mme a^a;1mA IED wv,NDM JRAn a ro O0.>m � -(2) eLA ,'R%a.' as w,IAwOn 4w n (D Ac R saM Ba.Cmpa -(1)rNnm-IurPp A -(+)Dona Noe 5AY x W.Cw SLPPLr an-- CaMEUM n�SmINECDI4 MEANS NVLL BE WAB1E C xo.*rat A """'011e1"" )ARRAY GRWNO PER 690.47(D).NOTE PER EXCEPTION NO.Z,ADDITIONAL S AS SmM¢EOURPNT Nip SHNL BE RATED PER NFL _(I)aUPI1ERa Op10apB ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF(E)ELECTRODE ®�[�,A.E R THw-z ems rrTT,AMG 04 1XWFz Ooh 1 AMG/10.ArIN-a,eloA v«•.5m vx]a=15 A 2)—n4 w TWE Blas vm•.500 v.Ir-15 ADC (I)A.R—:zBel O6F(I)Aa n41XR✓-],Rtl OgT-(1)AC/Iq Tr111-2,W vvl* VDC Imp=1407 ADL O�(IIAFRSpBa Ba.I—EOC Vmp.1 v.1-5.5 ADC (I)A.0 RTINN-z.NN. IPVIRAE vmv=240 v,5c Imp=4S87AAL (t)ANC R4 ANN-z wM NEVIP/1 vmP-2 vnc rmv=2awAAc t)Ac/(q ixw-z uw�. Lor,....IX... .........((I)Ac.R.nPTI-z.pS.M^..Lpr,ATEA„-((IPA4i1.pP.J/fm.......... .......-.(,Awe R.nON-zP.wI..LPFA?p.-(!)fgw.e. m.......... [�i)A.0 d14 TNel-i BnIX •=500"VDC'lu=i5 ADC .......... a}Aw:n4 PY Wi[.Ek3.........Vm .SW'1.lu:i5 ADC ®ET'(I)AM RiN LNOA (i�AC R 1NPw-z Mva ©QSL(t)A.G pq TNMT-z le,e vmv=350 V.Imv=S75 A. O�(I)A.c Rsana a..cypa E0c ftp-7s0 voc ImP•t407 AK NAf(QAM%R MIN-z aw ®�(I)Acino, zaa .....F.i.(I AM n.4 n 4o.a..FR.......... .. ..�. ..... .3(I)A.0 R INWI-z MA. XEIIML Vmp=2b VAC MP=1S47MC IIIAc/141MM-z rNh NEDIRAL YmP=110 VAC Mp=TS AAC (I AM i1411a1FZ Bkd Yo<•=sbd"Y ':<-13 T�)AWIi n4 Pv wm riod a•'�W YDC Ix�n ADC i. ())AwC R.S4w BED.L'ip!..IZF.....-(I)ItM!I.wS.J/♦'.4?.......... ......-(Tc R.TI(wN&P.+1.,L4K/4L.-I0)W xlge.J/Ydi.......... O�0)Ac/141NM-2 ba Vmp=350 VDC Imp=I40)AD[ Op{�(1)AM1%-1 Bae C{ Ew V n=750 VDC Imp=8.75 AOC ........(1 AIE/(q TM..1-2 Cnn..Ippr.......... LL��(I Anjlo.NM-.R Va•-500..VDC�)u�=15..ADC .....EC.--��..(])A�C n4.PV w1�.MW.........Vu�';B00 46d iI,�iS ADC A.0 P4 TIMi-z Atl Vmp.350 VDC Imp=9.33 A ®pk(t)ACRSak Bn Crypr Eft Vmp.750 vDC Imp.1W]ADC SIT ff1t0,,� mM� JB-0181110 00 JUDY&JACK HHRH FR RES RESIDENCE ®®L�aRt4 N4pg4m BR�NEXOEFr L � = SolarCity. -s. R aE 01sa 0 M WCE an N Coln Maunl Type C 31 OXBOW CIR 12.495 KW PV ARRAY /r P.wr m a7IEI¢w15¢rIc IeanlTs wur.utnA DaPrM mealnl Wm I(49) NORTH ANDOVER, MA 01845 t1E sAtE AND IH err nc RESPECmE (49 CANADIAN SOLAR f CS6P-255PX SOIABOIY fMFINN;W1NOlI 1H Nlld rA2YIIG 9fE1: 3V: 41m h W a maBssa ap saNmrc.c Multi le Inverters 9788888589 THREE LINE DIAGRAM PV 5 c 1)/13/2004 (eeej-�-)an(ia+x1�)(°a°I m'an01x, t CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: -Address:31 Oxbow Cir INVERTER AND AC DC DISCONNECTDISCONNECT u ^ AC DISCONNECT r� INVERTER AND UTILITY DC DISCONNECT SERVICE SOLAR PHOTOVOLTAIC ARRAYS) ----------------------- PHMVOLTAIC BAC(—FED CRCUIT BIWAIER N MAN HECIWk PMEL IS AN A/C DISC+ KCf PER NEC 890.17 OPERATING VOLTAGE=240V JB-0181110 00 00NT11rt0 swi Xeiff�"+ne FERRES, JUDY& JACK FERRIES RESIDENCE Lana Na am �r � °� � mp =" SolarCity. "gin" Com Mount T e C 31 OXBOW CIR 12.495 KW PV ARRAY raw m+.cmrr"mmErnon"m NORTH ANDOVER, MA 01845 ne sue"u usP rc mP PL44 49 CANADIAN SOLAR CS6P-255PX u s: O+w 9tlp z w++ P0.1P" .■e1011 TE"di4X � P/S NNG 9EFT. RC MR IYbnyy IN P55i °61S90X0-m Multiple Inverters 9786888569t60t6B'0°" 60.101 SITE PLAN PLACARD PV 6 C 11/13/2014 1 Label Location: _ Label Location: Label Location: E (C)(CB) (AC)(POI) (DC)(INV) Per Code: Per Code: Per Code: NEC 690.31.G.3 NEC 690.17.E NEC 690.35(F) Label Location: , TO BE USED WHEN (DC)(INV) INVERTERS Per Code: . UNGROUNDED NEC 690.14.C.2 Label Location: Label Location: (POI) (DC)(INV) Per Code: Per Code: INVERTER OI1T1tJT NEC 690.64.8.7 CONNECTION NEC 690.53 00 NOT RELOCATE THIS OVERCURRENT DEME Label Location: PHOTOVOLTAJCPOiNTOl (POI) Label Location: Per Code: It ELECTRIC SHOCK (DC)(CB) NEC 690.17.4;NEC 690.54 Per Code: NEC 690.17(4) BOTH THE LINEAND LOAD SIDE M3 Label Location: (DC)(INV) Label Location: Per Code: CAUTION (D)(POI) NEC 690.5(C) Per Code: NEC 690.64.8.4 Label Location: jjjj� Label Location: CAUTION (POI) (AC)(POI) Per Code: (AC):AC Disconnect Per Code: NEC 690.64.8.4 (C):Conduit PHOTOVOLTAIC SYSTEM NEC 690.14.C.2 (CB):Combiner Box (D):Distribution Panel (DC):DC Disconnect Label Location: (IC):Intenor Run Conduit (AC)(POI) (INV):Inverter With Integrated DC Disconnect Per Code: (LC):Load Center NEC 690.64 (M):Utility Meter (POI):Point of Interconnection nc eo art�rs.wT sa�iaan nc�.01 srs I us�a. W W U E m PM1 0 0 W1190 � s OP4NRA p. SC Label Set ENQPT N fM2CipM WM ilE SNE IrD Uff Of ME W:SHCiNF 11 6rtv S0.MN1Y E0.PYFN1,WMpR 111E WiniCN MAlIS9M U 5¢.WO1T HC f SolarCity SleekMountTM-Comp SolarCity SleekMount`rm-Comp The SolarCity Slo*Momt hardware solution •Wires Zap Saar hardwae and ULmarled �.: '` � Installation Instructions is optimized to achieve superior strength and Zep Corroetitl4a-modules aesthefic bile minimizing roof diarupli n and .� Drill Piot Hole a Proper Diameter far Labor.The etlminatbn of NsiDle mil ends and 'Interlock am gmundng denims in a).—UL fisted to UL 2703 Sealener Size Per NDS Section 1.1.3.2 maiming clamps,combined with the addition �akk of army him and a lower profile all contribute •Interlock and Ground Zap En.Wed to UL 1703 �� �lr Seal pia n rmfirg sedan o a more Nsuelly appealing sym as stem.sle".u 'Grounding and Bor r g Sysian' utilizes Zap Compatible'-modules with .Gmmd Zap UL and LTL listed to UL 467 as \ ®� p ouflaY�rg ands upper of shlng� strengthened frames that attach directly to grounding device Zap Solar standoffs.effectively eliminating the - 8 Race Camp Mont cenleratl need for roll and reducing the number of 'Painted gaWaniz¢d waterproof flashing upon lashing standoffs required.In addition.composition ,Anodized cavpaiems ler corroslon Insall leg pursuant to NDS S—Ion 11.13 shingles are not required to be cul for this v system,allowitlg for minimal roof disturbance. •Appk isle for van spanning funabn �a with sealing washer. Secure Leveling Foot to the Camp Moira usng machine Screw Racer We ® Components ®SMS'Machine Screw ®Levditg Foot L-g— a ®Carp Mord 'e as ® ®Carp Moam Flashing _ r ® • ii`VO1aFCity January2013 1- % (D 3.So�BrGitji January 2013 dge CS6P-235/240/245/250/255PX Ne� � CanadianSolar ElectrlcalData Black-framed Temperature Characteristics NewEa e oue,a + Black-framed a.ea.�y Performance at Low Irradiance 5/240/24 1 ®.assn.- tmaaayk.aAm P.rt«mara.a+t•n lmabdaa =»a+..v .nwmm•m.ws.ax n•ad,•rt iaacylmm.n aw�oo.a�„„ etldgpnm•rozogtnm' Next Generation Solar Module tAu+.s.zs cl N—Edge,-nett gmauron imide deaipnea r«m+trmk � Engineering Drawings tywa m nnpnary ayare�.Pnen walmaera as aaxe yeme Dr minimal s»um<osb.aeew.m•eamkaa 15 mMdZe � tpetlb « at 11111 1111111111 MYaaatlOnaM OwlnOusbys mostrerubkgr«aM'vg Mechanical Data cyamm.TMm I.wa ao ffiide PdymrYeane =+u...x-aeieene Key Features >liopncxsiamkat•a amnea+dmteca an.efane pained c+w-o•-.+ =+m aimlgac_4ed aamaaan.llrekcbeamea CS6P-Px • 0u...n esauen 1-Mma6uay bOm arrtarws Mnrtekolmp ArakW aey, maplaaaar z «auaskau0atim tMe «u0ryaesmnk_Weaim kwensyamm mu �mnrwn,eUn, Loaeraystemmau-cem-rmaop �� • kafflimces l.hw Best Quality vas.amea,. •=Vualay mmol Pdnb M ecaule Precut— mnylEgnzAa4ul4+«e.. • AeadmS<•eemlesaaPPearance-ins ProOb ELa«saning to e0minete Proaud defects GCO'°a-ter I atm autolevding ens etigmmnt •Curunt nindng to Mmrpye ayamm pedormanceer" mO�ana�t wNa,� - • aum-InA •Accudi[ed can mint rosiateM *~'�O���Pet" 1 c +�1O+ ywr-eendea9mur�6rp.yabm-atra mounted.We prpuridedI•V Curves(C86P-233PX) i Best Warranty Insurance -. � i • Tn.ft—w ramaan 35ye—MV cc-reg. •100%dsngM ytarm rawrdga •• smm,", • umaamaPmtacpum-3wnar«mPnunv <mo •Prowmngmira pameenwwc<yrynb - aMgumdirperitem Nm-unPNude • Inawo-ysaatmmPranenaiaa.bnantyxnman<aq. •Immeakmwaeraga !!` ;(� Aleeatuteakaaiap Maunnu<«nwniee in me Ina«edey3emdatop(n,uumecompanies . narM Comprehensive Certificates _ — • MduatrykNing panenrypaaerroknnce:0-e5W ,IEC 6131 a.IEC 61130,1.05110+ED].U11103. • Bac_M m.Patibliit�Mmaa sbMam rccllopaM CECLiafaa,CEand MCS -- «outs mounllrg ayatam• IS09001:30oa:0ue6ry Management System -^ .ISOrtS159<9:g009:TM auomotlw 0ua0+Y '�-"�"""•^�<"'<•'r`='^a+.•.b•'•^a.ew. • 6a<k•day Our N•r 1dR6Llmar Povmr Wartanty IS0140mentayamm Plus our•aa.azsyev M•wan<•<oveng• IS0ta00L2o01:SkMaNslorEmtrmmental About Canadian Solar ana9emeniiya[em Gnaiae agar be b•ro«[M neACa krpast.<In Cmanan aeln na•tovrWeO m Cavada m 3001 a oe +Ltii •00080000 HSPM:TM CerSlfutbnf« can<.•<.A•a 1•aeina r•rti<aliy-1n«y ue•vcwmV,of den a--!«Mnaa(aTa6e1:C,no)In Adaa yA„E Hazardous SI200 1 Regda6ma ^b<e^<•MI^a°r<•art••<,c•W,Wm°duW eM NarenMr 200E C<nadl,n solar nm nedak nuurxluMg rom xan,nty .OMSA615001:3001Intema6onalabndaNsl« aprt�Mueu N r•<PmpioN<i.q y��orr1�N uP•enYM3AsaYaM ctl nanafacm•mg<ap.Ya1.3oM. o pe9onal hash n pmd,ndabn+.<ntrmbnedeuabna.mkmbananP Off'*�CfaF'sCail�ryfbS ap+eom<l•a+•a1+e„+ob aim aafv<tlwen•,•yM ntlim U,Nern ae<barammamsaan. om1 REACH C—Pram :121"1 5yeeeaxr mfy««—ty wuw.ea nadia nsolar.cpm t 4 i solar-a a T • solar-..6 SolarEdge Power Optimizer Module Add-On for North America P300/P350/P400 SolarEdge Power Optimizer Module Add-On for North America P300/P350/P400 • w • ;o wr..roa w;n,nn o....o .. .�w� o---------.,�x�[;m,o,r,.[a[c.osF : .tr .w w;w[ Now Nsruu„o.v.c;ns.noxn uwww..uwa.+nx•.w,m w ka:xrcnur ; r tx - PV power optimization at the module-feval o -wnnw eunma�assf1 m�e .o«mw.. .. .. navµee, x.r,n.�oa.mu,n�rx.wa x�,arr..w wmwr-a raoao-re wx,R.a,w+aw�ra.mro,r,.a�.o-.mro usn cx.vsar r.�rr ru,[[ :nvu was vavr ar�sms,u www.solareege.us Single Phase Inverters for North America solar=@ * solar=ss z SE30MA-US I S'390DA-S/SEMDDA-US/SE60OA-US SE7600A US SEICODOAU-US I SO 14MA-US SolarEdge Single Phase Inverters I j— I— For North America IT. SE3000A-US/SE380OA-US If SE500DA-US/SE600DA-US/ S E760OA-U S S El ODOOA-U S SEI 140 OA-U S f ELI Fo I, ........ ....... . ......................... 4 ........... . ..... A ........... ...... Ta 11.A. ...IS. ,•ouw] ............................. 15 ............ ........ a --sit ........... ad.—RIATINIES ,Camueoamrme _--all ........... ....—FILEARPE. ---------------------------- R_.SHEERENEAEREN,H ............ ................. The best choice for SolarEdge enabled systems RFRM,Arddamfwkpotdcden(rpe,1)for NEC 2011690.11compliar,ce I/-c S.Fericwr efflNNIc,,(M) ............ ST,4491RAeINT and easy.omsml on P,-Id.d tNRE. ftift-Ir,Ieddo ,,Ael".1eriRs IHEN—ed—It..Sh-,,F.er Wireless 0,Pd—IRNI NNk,d,INS,.N.H. rued dIrap 11 DC/AC.—N..only ACIMSafety Switch for I— OPUdraI–I,—grade d2u,AHSI CMI LFSA'GERALANI-ITAIV-FRANCE-JAPAN CHINA ALI—A-THE NETHERLANDS ISRAEL Ay solaredge-us ■ so I a r " @ • ! so I a r ' • q SolarEdge Power Optimizer Module Add-On for North America P300 / P350 / P400 SolarEdge Power Optimizer P300 P350 P400 Module Add-On For North America (fors°-cell Pv (for72-ceIIPV (for 9&ceIIPV modules) modules) modules) P300 / P350 / P400 INPUT Rated Input DC Power"� 300 350 400 W ....................................................................................................................................................................... Absolute Maximum Input Voltage(Vo c at lowest temperature) 48 60 80 Vdc ............................................................................................................................................................................ MPP70perating Range 8-48 8-60 8-80 Vdc ............................................................................................................................................................................ ■ Maximum Short Circuit Current(Isc) 10 Adc Maximum DC Input CurrentAdc ................................................................................................................ .......... 12.5.................................................... Maximum Efficiency99.5 ......................................................................................................................P.S.................................................... Weighted Efficiency 98.8 .............................................................................................................................................................................. Overvoltage Category II OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) _ Maximum Output Current 15 Adc Maximum Output Voltage olt B.............. .............. ............... ........ ......... .......... Maximum Out ut Volta a 60 Vdc ■ OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class 8,IEC61000-6-2,IEC63000-6-3 ................................................................................................................................................................. } Safety IEC62309-1(class II safety),UL3741 RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc .............................................................................................................................................................................. Dimensions(WxLx H) ...1.4.1.x 212 x40.5/S.SSx8.34x1.59 mm/in Weight(including cables) 950/2.1 gr/lb ...................................................................................................................................................................... ... Input ConnectorMC4/Amphenol/Tyco Output.W ire.Type./Connector .......... Double l nsulated;AmPhenol ............. Output Wire Length........................................................... ::95./.3: .......I.......................1:?.�.3:9........................ m/ff Operating Temperature Range40-+85/-40-+185 'C/'F .............................................................................................................................................................................. Protection Rating IP65/NEMA4 .............................................................................................................................................................................. Relative Humidity............................................................................................0-100 % Irl fttt STC powerd toem 1.0 —.1-1.o.+s.power rolerante alloweo. PV SYSTEM DESIGN USING A SOLAREDGE SINGLE PHASE THREE PHASE THREE PHASE INVERTER 208V 480V PV power optimization at the module-level Minimum String Len g[h(Power Optimizers) 8 10 1R Up to 25%more energy Maximum String Length(Power Optimizers) 25 25 50 .......................................................................... .............................................................................................. Maximum Power per String 5250 6000 12750 W Superiorefficient 99.5% ....................... .................................................................................................................................................. P y( ) Parallel Strin sof Different Len hs or Orientations Yes — Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading """"""""'g"' """"""'..'..."`.""'""""""""..."""""'""""......'.........""""""""""""""""""""""""'... — Flexible system design for maximum space utilization — Fast installation with a single bolt — Next generation maintenance with module-level monitoring — Module-level voltage shutdown for installer and firefighter safety USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. 1 CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING P01 POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT WNEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 STRUCTURAL VIEWS LICENSE GENERAL NOTES PV5 UPLIFT CALCULATIONS PV6 THREE LINE DIAGRAM GEN #168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION Cutsheets Attached ELEC 1136 MR OF THE MA STATE BUILDING CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE INCLUDING • • • MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: ZEP SOLAR AHJ: North Andover REV BY DATE COMMENTS REV A NAME DATE COMMENTS * * * * UTILITY: National Grid USA (Massachusetts Electric) * * * * JB-01 81110 00 PREMISE oNNER: DESCRIPTION: DESIGN: CONTAINED L A THE INFORMATION HEREIN JOB NUMBERFERRIES, JUDY FERRES RESIDENCE Y 9 �• solarCity.CONTAINED SHALL NOT E USED FOR THE Lallto Na a amI,BENEFlT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: � NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 31 OXBOW CIR 17.34 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES: NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St. Martin Who,Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (68) CANADIAN SOLAR # CS6P-255PX PAGE NAME: SHEET: REk DATE- Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER T: (650)638-1028 F: (650)638-1029 PERMISSION of SOLARCITY INC. SOLAREDGE # SE760OA—USOOOSNR2 9786888589 COVER SHEET PV 1 10/3/2014 (M)_SOL-CITY(765-2489) ww..sdareity.eom PITCH: 35 ARRAY PITCH:35 MP1 AZIMUTH: 103 ARRAY AZIMUTH: 103 o MATERIAL: Comp Shingle STORY: 2 Stories o PITCH: 35 ARRAY PITCH:35 MP2 AZIMUTH:283 ARRAY AZIMUTH: 283 K' MATERIAL: Comp Shingle STORY: 2 Stories PITCH: 35 ARRAY PITCH:35 MP3 AZIMUTH: 110 ARRAY AZIMUTH: 110 MATERIAL: Comp Shingle STORY: 2 Stories C PITCH: 35 ARRAY PITCH:35 MP4 AZIMUTH:290 ARRAY AZIMUTH: 290 MATERIAL: Comp Shingle STORY: 2 Stories M a LEGEND ® Q (E) UTILITY METER & WARNING LABEL Q 10 Inv INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS DC DC DISCONNECT & WARNING LABELS B A tNOF © AC DISCONNECT & WARNING LABELS gr Q Front Of House YOO JIM DC JUNCTION/COMBINER BOX & LABELS K Q DISTRIBUTION PANEL & LABELS No.4 Lc LOAD CENTER & WARNING LABELS ° Digitally oo Jin Kim O DEDICATED PV SYSTEM METER Date: 20 4.10.03 14:50:44 0 STANDOFF LOCATIONS -07'00' � CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR 3 ❑ GATE/FENCE r--T- N B , AC i,' 0 HEAT PRODUCING VENTS ARE RED iG�iIE=I� D 11 'i INTERIOR EQUIPMENT IS DASHED O1% L--'J Ise SITE PLAN LG Scale: 3/32" = V E W 0 1' 10' 21' I x k5 J B-0181110 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: a CONTAINEDDSHALL NOT BE USED Lalita Naam D FOR THE FERRES, JUDY FERRES RESIDENCE Y 9 BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: •.� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 31 OXBOW CIR 17.34 KW PV ARRAY 71 `SolarCit PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St Martin Drive, Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (68) CANADIAN SOLAR # CS6P-255PX PAGE NAME SHEET; REv DATEM°rlbarougn, MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER T. (850)838-1028 F. (650)838-1029 PERMI$�AN of solJ�RaTY INC. SOLAREDGE SE7600A–USOOOSNR2 9786888589 SITE PLAN PV 2 10/3/2014 (8BB)—SOL-CITY(765-2489) www.solarcity.eom Alk (E) 2x4 (E) 1x8 E) 2x8 2x4 sl S1 4" 0 14'-9" 0 14'-10" (E) LBW (E) LBW SIDE VIEW OF MP2 NTS SIDE VIEW OF MP1 NTS B A MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES MPI X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 64" 24" STAGGERED LANDSCAPE 64" 24" STAGGERED PORTRAIT 48" 20" PORTRAIT 48" 20" RAFTER 2X8 @ 16"OC ROOF AZI 283 PITCH 35 STORIES:2 ARRAY AZI 103 PITCH 35 ARRAY AZI 283 PITCH 35 RAFTER 2X8 @ 16"OC ROOF AZI 103 PITCH 35 STORIES:2 C.J. 2X10 @16"OC Comp Shingle C.J. 2x10 @16"OC Comp Shingle OF sl S1 Y00 JIN K Yi No.a 0 12'-10" jk (E) LBW AL 0 12'-10" SIDE VIEW OF MP3 NTS Digitally igned by Yoo Jin Kim (E) LBW C Date: 2014.10.03 14:50:51 -07'00' SIDE VIEW 0 F M P4 Ni s MP3 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER I NOTES i D LANDSCAPE 64" 24" STAGGERED PORTRAIT 48" 20" 1 MP4 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES RAFTER 2x8 @ 16"OC ROOF AZI 110 PITCH 35 STORIES: 2 LANDSCAPE 64" 24" STAGGERED ARRAY AZI 110 PITCH 35 C.J. 2x8 @16"OC Comp Shingle PORTRAIT 48" 20" RAFTER 2X8 @ 16"OC ROOF AZI 290 PITCH 35 STORIES: 2 ARRAY AZI 290 PITCH 35 C.7. 2x8 @16"OC I Comp Shingle JB-01 81110 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: : . CONTAINED AL— THE INFORMATION HEREIN JOB NUMBERFE R R E S, JUDY D Y CONTAINED SHALL NOT E USED FOR THE FERRES RESIDENCE Lalita Nayagam SolarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �.��& NOR SHALL IT BE DISCLOSED IN MOLE OR IN Comp Mount Type C 31 OXBOW CIR 17.34 KW PV ARRAY l�� PART TO OTHERS OUTSIDE THE RECIPIENT'S MoouLEs NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St. Martin Drive, Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (68) CANADIAN SOLAR # CS6P-255PX PAGE NAME SHEET: REV DATE: Marlborough, MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T: (650)638-1028 F. (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE760OA—USOOOSNR2 9786888589 STRUCTURAL VIEWS PV 3 10/3/2014 (888)-SCI-CITY(765-2489) www.solarcity.com PV MODULE 5/16" BOLT WITH LOCK F INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. H OF (4) (2) SEAL PILOT HOLE WITH ?� �► ZEP COMP MOUNT C POLYURETHANE SEALANT. Y00 JIN + K ZEP FLASHING C (3) (3) INSERT FLASHING. I y No,4 (E) COMP. SHINGLE (1) (4) PLACE MOUNT. (E) ROOF DECKING (2) INSTALL LAG BOLT WITH 5/16" DIA STAINLESS (5) (5) SEALING WASHER. Digital signed by Yoo Jin Kim STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULESINSTALL LEVELING FOOT WITH Date:2014.10.03 14:50:59 WITH SEALING WASHER (6) BOLT & WASHERS. (2-1/2" EMBED, MIN) -07'00' (E) RAFTER 1 STAN DOFF CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER JB-01 81110 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINEDDAL SHALL NOT BE USED FOR THE FERRES, JUDY FERRES RESIDENCE Lalita Nayagam �_ a BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: •�����0'�! � � •0 SHALL ALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 31 OXBOW CIR 17.34 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES. NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St. Martin Drive, Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (68) CANADIAN SOLAR # CS6P-255PX PAGE NAME SHEET: REV DATE: Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER T. (650)638-1028 F. (650)638-1029 PERMISSION OF SOLARCITY INC. ISOLAREDGE SE760OA—US000SNR2 9786888589 STRUCTURAL VIEWS PV 4 10/3/2014 (888)-SOL-CITY(765-2489) www.solarcity.com UPLIFT CALCULATIONS SEE SEPARATE PACKET FOR STRUCTURAL CALCULATIONS. CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-01 81110 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT USED FOR THE FERRIES, S JUDY FERRES RESIDENCE Lalita Nayagam �: ��a�C.�ty. BENEFIT OF ANYONE EXCEPT SOLARgTY INC., MOUNTING SYSTEM: �.,�3 NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 31 OXBOW CIR 17.34 KW PV ARRAY ;,S PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH � 24 St Martin Drive, Budding 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (68) CANADIAN SOLAR # CS6P-255PX Marlborough,MA Building Z SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEET- REV: DATE: T. (650)638 Marlborough, F. (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE # SE7600A—USOOOSNR2 9786888589 UPLIFT CALCULATIONS PV 5 10/3/2014 (888)-SOL-CITY(765-2489) www.solarcity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO TWO (N) GROUND Panel Number:G4040MB1200 Inv 1: DC Ungrounded INV 1-(11)SOLAREDGE jS�EE6o00A-US00DSNR2A -(66)CANADIAN SOLAR # CS6P-255PX GEN #168572 ODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:12807069 Inv 2: DC Ungrounded Inverter, 6000% 24OV/208V, 97.596 w/Unifed Disco and ZB,RGM,AFCI PV Module; 255W; 234.3W PTC, Black Frame, MC4, ZEP Enabled ELEC 1136 MR Underground Service Entrance Tie-In: Supply Side Connection INV 2-(I)SOLAREDGE I SE760OA-USOOOSNR e Inverter 76 W, 240V, 97.SR w n1 Isco and ZB, RGM, AFCI Voc: 37.4 Vpmox: 30.2 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL E 20OA/2P MAIN CIRCUIT BREAKER Inverter 1 (E) WIRING CUTLER-HAMMER BRYANT Disconnect CUTLER-HAMMER (N) 125A Load Center 20OA/2P l0 Disconnect 9 7 SOLAREDGE B 80A D SE6000A-US0O0SNR2 C 35A/2P SolarCity A L1 znov 2 - - - 1 B L2 A DC+ N 5 DC- (E) LOADS GND ____ GND _ _ EPC/ -__ DC+ DC+ - MP 2: 2x14 _ -� o -------------- GEC l I _ N DG DG GND EGC-------------------- ------- -- EGC - - -'----- - ---------- ----I I } J N i I I Inverter 2 El EGGGEC I B SOLAREDGE I i SE760OA-USOOOSNR2 I I I 40A/2P I - GEC L1 zaov U�D - - - Lz I To 120/240V N 6 ❑ MP 1,2: 1x19 SINGLE PHASE I I L_ ____-_____--_--- _ EGC/ ___ DC+ - MP34: 1x19UTILITY SERVICE I I GEC T N DC- l I I I I GND -_ EGC--------------------------- - -,----- --EGC --------- - -- J I I I I I I PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Voc* = MAX VOC AT MIN TEMP p�I (2)Ground Rod; 5/8' x 8', Copper B (1)CUTLER-HAMMER #DG223NRB A (1)SolarCitYL�##4 STRING JUNCTION BOX -(2)ILSCO f IPC 4/0-2/0 Disconnect; 1ODA, 24OVac, Fusible, NEMA 3R AC 2x2 SIRMGS, UNFUSED, GROUNDED DC Insula ion Piercing Connector, Main 4/0-2, Tap 2/0-6 -(1)CUTLER- AMMER DG10ONB D Ground�Neutralt; 60-100A General Duty(DG) PV (66)SOLAREDGE,jP300-2NA4AZS (1)BRYANT#BR816L125RP -(1)CUTLER-HAMMER #DS16FK PowerBox optimizer, 30OW, H4, DC to DC, ZEP Load Center, 125A, 120/24OV, NEMA 31? Class R Fuse Kit -(1)CUTLER-HAMMEJt f BR235 -(2)FERRAZ SFIAWMUT#TR80R PV BACKFEED OCP n d (1)AWG #6, Solid Bare Copper Breaker, 35A 2P, 2 Spaces Fuse-, SOA, 250V, Class RK5 -(1)Ground Rod; 5/8' x 8', Copper -(1)CUTLER-HAMM R #BR240 Breaker, 40A 2P, 2 Spaces C (1)CUTLER-HAMMER #DG323URB N ARRAY GROUND PER 690.47 D NOTE: PER EXCEPTION N0. 2, ADDITIONAL SUPPLY SIDE CONNECTION. DISCONNECTING MEANS SHALL BE SUITABLE Disconnect; 100A, 24OVac, Non-Fusible, NEMA 3R ( ) ( ) S AS SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. -(I)GILERd NeMME.traR 0 D6000r00A, General Duty(DG) ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE r.01 AWG 14, THWN-2, Black L L1 AWG #8, THWN-2, Black (1)AWG fB, THWN-2, Black Voc* =500 VDC Isc =30 ADC 2 AWG #10, PV WIRE, Black Voc* =500 VDC Isc =15 ADC O L L(1)AWG#4, THWN-2, Red O (1)AWG #8, THWN-2, Red t. .5 1 � (1)AWG /8, THWN-2, Red Vmp =350 VDC Imp=20.14 ADC O � (1)AWG #6, Solid Bare Copper EGC Vmp =350 VDC Imp=10.07 ADC I (11)AWG 14, THWN-2, White NEUTRAL Vmp =240 VAC Imp=57 AAC (1)AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp 25 AAC (1)AWP #10, THWN-2,.Green EGC. . . 0)Conduit Kit; 3/4' EMT . . . . . .70)AWG #8,.THRN-2,.Green . . EGC/GEC.-0)Conduit,Kit;.1'.EMT. . . . . . . . . . . . .. . . . . .-(1)AWG #8,.TFIWN-2,.Green , , EGC/GEC,-(1)Conduit,Kit;,3/4'.EMT. . (1 AWG #8, THWN-2, Black Voc* =500 VDC Isc =30 ADC (2)AWG 0, PV WARE, Block Voc* =500 VDC Is =15 ADC �(1)AWG #4, THWN-2, Black (11)AWG #8, THWN-2, Black ©PF(1)AWG #8, THWN-2, Red Vmp =350 VDC Imp=27.32 ADC O (1)AWG #6, Solid Bare Copper EGC Vmp =350 VDC Imp=10.07 ADC (1)AWG #4, THWN-2, Red ®L L(1)AWG #8, THWN-2, Red . . . . . . . . (1)AWG #10, THIWJ-2,.Green. . EGC. . . . 0)Conduit.Kit;.3/47.EM.T. . . . . . . . . . I" (I)AWG#4, THWN-2, White NEUTRAL Vmp =240 VAC Imp-57 AAC (1)AWG 0, THWN-2, White NEUTRAL Vmp =240 VAC Im -32 AAC . . . . . . . . . * . . C. , . p- ( ) #1 p p- (2)AWG #10, PV WARE, Black Voc 500 VDC Isc 15 ADC . . _ . .-(1)AWG #6,,Solid Bare.Copper. GEC. . . . (1)Conduit.Kit;.1'.EMT. . . . . . . . . . . . . . . . . . .-(1)AWG #8,,THWN-2,.Green . . EGC/GEC.-0)Conduit.Kit;.3/47 EMT. . . . . . O (11)AWG #6, Solid Bare Copper EGC Vmp =350 VDC Imp-13.66 ADC O4 (2)AWG #10, PV WIRE, Black Voc* =500 VDC Isc =15 ADC (1)AWG #6, Solid Bare Copper EGC Vmp =350 VDC Imp=13.66 ADC CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER PREMISE OWNER: DESCRIPTION: DESIGN: JB-0181110 00 '_1%N. I r CONTAINED SHALL NOT USED FOR THE FERRES, JUDY FERRES RESIDENCE Lalita Nayagam �O �'I �� BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �.� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 31 OXBOW CIR 17.34 KW PV ARRAY h� PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES- NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH ' THE SALE AND USE OF THE RESPECTIVE (68) CANADIAN SOLAR # CS6P-255PX 24 St Martin Drive, Binding 2, Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEET: REV- DATE T. (650)B3B-1028,F. (6A1752 638-1029 PERMIS40N OF SOLARCITY INC. SOLAREDGE SE760OA-USOOOSNR2 9786888589 THREE LINE DIAGRAM PV 6 10/3/2014 (868)-SOL-CTY(765-2489) www.solarcity.com CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 31 Oxbow Cir INVERTER AND AC DC DISCONNECT DISCONNECT AC DISCONNECT ii ii ii ii INVERTER AND UTILITY DC DISCONNECT SERVICE --------------------------� SOLAR- PHOTOVOLTAIC ARRAYS) PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-01 81110 00 BENEFIT OF ANYONE EXCEPT PREMISE OWNER: DESCRIPTION: DESIGN: `\`t CONTAINED SHALL NOT EPT SOLARCITY INC., MOUNTING SYSTEM: ' ���a USED FOR THE FERRES JUDY FERRES RESIDENCE Lalita Nayagam ' So�arCity. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 31 OXBOW CIR 17.34 KW PV ARRAY PART IZ OTHERS OUTSIDE THE CONNECTION WITH MODULES: NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH � 24 St. Martin Drive,Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (68) CANADIAN SOLAR # CS6P-255PX REV OAS Marlborough,MA ing Z SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME T. (650)638-1028 F. (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE7600A-USOOOSNR2 9786888589 SITE PLAN PLACARD PV 7 10/3/2014 (666)-sol-CITY(765-2489) ,, ,.5alaraitr.a«n Label tion: Label Location: Label 11IARNING:PHOTOVOLTAIC POKIER SOUP,CE Code:Per I WA R N.I N G :_ ;'_ WARNING _Per Cod : NEC Location: 6. ELECTRIC SHOCK HAZARDNEC 6. ELECTRIC SHOCK HAZARD E NEC 690.35(F) 3119110OT TOUCH TERMINALS THE OWN*] OF THIS Label Location: TERMINALS ON BOTH LINE AND PHOTOVOLTAIC SYSTEM ARETO BE USED WHEN PHOTOVOLTAIC DC LOADN D OPEN POSNTIONIZED MAY BEOINVERTERIS ENERGIZED DISCONNECT Per Code: UNGROUNDED NEC .•0 LabelLabel • WARNING MAXIMUM POWER- A D INVERTER OUTPUT 690.64.13.7 POINT CURRENT(Imp)_ Code: CONNECTION MAXIMUM POWER VNEC 690.53 DO NOT RELOCATE POINT VOLTAGE(Vmp) MAXIMUM SYSTEh9 THIS OVERCURRENT VOLTAGE(Voc)_v DEVICE SHORT-CIRCUIT CURRENT(isc} A Label • • PHOTOVOLTAIC POINT OF '• Label Location: INTERCONNECTIONPer Code: _ WARNING: ELECTRIC SHOCK NEC 6. 6. 0.54 Per WARNING HAZARD. DO NOT TOUCH Code: NEC TERMINALS.TERMINALS ON ELECTRICAL SHOCK HAZARD BOTH THE LINE AND LOAD SIDE DO NOT TOUCH TERMINALS MAY BE ENERGIZED IN THE OPEN TERMINALS ON BOTH LINE AND POSITION. FOR SERVICE LOAD SIDES MAY BE ENERGIZED DE-ENERGIZE BOTH SOURCE IN THE OPEN POSITION AND MAIN BREAKER. DG VOLTAGE IS PV POWER SOURCE ALWAYS PRESENT WHEN MAXIMUM AC A SOLAR MODULES ARE OPERATING CURRENT EXPOSED TO SUNLIGHT MAXIMUM AC OPERATING VOLTAGE V Label • • WARNINGLocation: Per Code:ELECTRIC SHOCK HAZARD � �NEC 690.5(C) CAUTION Code: IF A GROUND FAULT IS INDICATEDPHOTOVOLTAIC SYSTENi NORh1ALLY GROUNDED CIRCUIT IS BACKFED 690.64.13.4 CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED Label • • Label Location: CAUTION '• PHOTOVOLTAIC AC DUAL POWER SOURCEDisconnect AC DISCONNECT PHO OVOLTAOIC SYSTEh1 690.64.13.4 , •I3I Conduit NEC 6.0 :. Conduit(D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Label Location: (INV): Inverter With Integrated DC Disconnect naAxlnluM Ac A '•I) (LC): Load Cente CURRENTPer Code: Meter(M): Utility h1AXIMUM ACNEC 690.54Point of • • OPER,4TING VOLTAGE _ .IIIA. 111111111•�111 111 /1111111/ 111'.11111 LabelSC IIIIIII1111IIIIIILIII11 11111111I11111IIIIIIIII1111 / 1 1 1 ' , III111!II:/ [I 11111111111111111'1���111111i 11111111111 SolarCity SleekMountT"" - Comp SolarCity SleekMountT"' - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed - Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM modules r aesthetics while minimizing roof disruption and Drill Pilot Hole of Proper Diameter for isted to UL 2703 labor.The elimination of visible rail ends and •Interlock and grounding devices in system UL Fastener Size Per NDS Section 1.1.3.2 l mounting clamps, combined with the addition of array trim and a lower profile all contribute •Interlock and Ground Zep ETL listed to UL 1703 Q Seal pilot hole with roofing sealant to a more visually appealing system.SleekMount as"Grounding and Bonding System ' pp g " y t'3 Insert Comp Mount flashing under upper utilizes Zep Compatible TM modules with •Ground Zep UL and ETL listed to UL 467 as layer of shingle strengthened frames that attach directly to grounding device Zep Solar standoffs, effectively eliminating the — ® Place Comp Mount centered need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition .Anodized components for corrosion resistance O5 Install lag pursuant to NDS Section 11.1.3 shingles are not required to be cut for this with sealing washer. system, allowing for minimal roof disturbance. •Applicable for vent spanning functions \\ © Secure Leveling Foot to the Comp Mount using machine Screw O7 Place module ® Components ® (3) 5/16"Machine Screw ® Leveling Foot ellb © Lag Screw QD Comp Mount 0 0 Comp Mount Flashing C sem' O o o� l� O all r ►1 SolarCity. F%0 \Ilr V� LISTED �it�SolarCity m January 2013 m January 2013 �OMPPr tc Des%" ®��� CS6P-235/240/245/250/255PX Neeaythlo�gh -� CanadianSolar Electrical Data Black-framed STC CS6P-235P CS6P-240P CS6P-245P CS6P-250PXCS6P-255PX Temperature Characteristics Nominal Maximum Power(Pmax) 235W 240W 245W 250W 255W _ _ Optimum Operating Voltage(Vmp) 29.8V 29.9V 30.OV 30.1V 30.2V Pmax -0.43%/-C Optimum Operating Current(Imp) 7.90A 8.03A 8.17A 8.30A 8.43A Temperature Coefficient Voc -0.34%rC Open Circuit Voltage(Voc) 36.9V 37.OV 37.1V 37.2V 37AV Isc 10.065%/•C Bl _ Short Circuit Current(Isc) 8.46A 8.59A 8.74A 8.87A 9.00A Normal Operating Cell Temperature q5±2'C • • Module Efficiency 14.61% 14.92% 15.23% 1 15.54% 15.859/6 Operating Temperature -40•C-+65^C Performance at Low Irradiance Maximum System Voltage 1000V IEC /600V UL Industry leading performance at low irradiation Maximum Series Fuse Rating 15A environment,+95.5%module efficiency from an Application Classification ClassA irradiance of 1000w/m'to 200W/m' Power Tolerance 0,5w, (AM 1.5,25-C) Next Generation Solar Module Under Standard Test Conditions(STC)ofirradianceofl000W/m',spectrum AM 1.5 and cell temperature of25V NewEdge,the next generation module designed for multiple Engineering Drawings NOCT CS6P-235PXCS6P-240PXCS6P-245P CS6P-250PXCS6P-255PX types of mounting systems,offers customers the added Nominal Maximum Power(Pmax) 170W 174W 178W 18lW 185W value of minimal system costs,aesthetic seamless Optimum Operating Voltage(Vmp) 27.2V 27.3V 27.4V 27.5V 27.5V appearance,auto groundingand theft resistance. Optimum Operating Current(Imp) 6.27A 6.38A 6.49A 6.60A 6.71A Open Circuit Voltage(Voc) 33.9V 34.OV 34.1V 34.2V 34AV The black-framed CS6P-PX is a robust 60 cell solar module Short Circuit Current(Isc) 6.86A 6.96A 7.08A 7.19A 7.29A Incorporating the groundbreaking Zep compatible frame. Under Normal Operating Cell Temperature,Irradianceof800 W/m',spectrum AM 1.5,ambient temperature 20'C, The specially designed frame allows for rail-free fast wind speed t mis installation with the industry's most reliable grounding Mechanical Data system.The module uses high efficiency poly-crystalline Cell Type Poly-crystalline 156 x 156mm,2 or 3 Busbars Key Features silicon cells laminated with a white back sheet and framed Cell Arrangement 60(6 x 10) with black anodized aluminum.The black-framed CS6P-PX Dimensions 1638 x 982 x 40mm(64.5 x 38.7 x 1.57in) • Quick and easy to install - dramatically is the perfect choice for customers who are looking for a high Weight 20.5kg(45.2 lbs) I I MII reduces installation time quality aesthetic module with lowest system cost. Front Cover 3.2mm Tempered glass Frame Material Anodized aluminium alloy • Lower system costs - can cut rooftop Best Quality J-Box IP65,3 diodes installation costs in half Cable 4mm'(IEC)/12AWG(UL),1000mm • 235 quality control points in module production connectors MC4 or MC4 Comparable • Aesthetic seamless appearance - low profile • EL screening to eliminate product defects Standard Packaging(Modules per Pallet) 24pcs with auto leveling and alignment • Current binning to improve system performance Module Pieces per container(40ft.Container) 672pcs(40'HQ) o • Accredited Salt mist resistant • Built-in hyper-bonded grounding system - if it's I-V Curves(CS6P-255PX) mounted,it's grounded Best Warranty Insurance • Theft resistant hardware • 25 years worldwide coverage I 100%warranty term coverage 0 1 SeclionA-A • Ultra-low parts count - 3 parts for the mounting • Providing third party bankruptcy rights 7 35.0 and grounding system • Non-cancellable e Immediate coverage • Industry first comprehensive warranty insurance by I o AM Best rated leading insurance companies in the Insured by 3 world top insurance companies 1 0 7.011 world v Comprehensive Certificates • Industry leading plus only power tolerance:0-+5W 15 • IEC 61215,IEC 61730, IEC61701 ED2,UL1703, n -''- -, • Backward compatibility with all standard rooftop and CEC Listed,CE and MCS ground mounting systems • IS09001:2008:Quality Management System l . ISO/TS 16949:2009:The automotive quality Specifications included in this datasheet are subject to change without prior notice. • Backed By Our New 10/25 Linear Power Warranty management system Plus our added 25 year insurance coverage • IS014001:2004:Standards for Environmental About Canadian Solar management system Canadian Solar Inc. is one of the world's largest solar Canadian Solar was founded in Canada in 2001 and was 190% • QC080000 HSPM:The Certification for companies. As a leading vertically-integrated successfully listed on NASDAQ Exchange (symbol: CS10) in Added Value pro Hazardous Substances Regulations manufacturer of ingots,wafers,cells,solar modules and November 2006. Canadian Solar has module manufacturing 90% m Warranty g solar systems, Canadian Solar delivers solar power capacity of 2.05GW and cell manufacturing capacity of 1.3GW. • OHSAS 18001:2007 International standards for products of uncompromising quality to worldwide 80% occupational health and safety customers. Canadian Solar's world class team of 0'/. s 10 1s zo Zs REACH Compliance professionals works closely with our customers to provide them with solutions for all their solar needs. On •10 year product warrant on materials and workmanship ;'P, w�crac cE •25 year near power output warranty o _`SP-u'`` to� v C.. E- www.canadiansolar.com EN-Rev 10.17 Copyright 0 2012 Canadian Solar Inc. r eel Version#39.1 �=0,5olar�Cit . 9 tH OF 3055 Clearview Way, San Mateo, CA 94402 �� Y00 AN (888)-SOL-CITY (765-2489) 1 www.solarcity.com K October 3, 2014 NC. Project/Job # 0181110 RE: CERTIFICATION LETTER M. Project: Ferres Residence Dig ita I l y Yoo Jin Kim 31 Oxbow Cir North Andover, MA 01845 Date: 2014.10.03 14:49:48 -07300' To Whom It May Concern, A jobsite survey of the existing framing system was performed by a site survey team from SolarCity. Structural review was based on site observations and the design criteria listed below: Design Criteria: -Applicable Codes = MA Res. Code, 8th Edition,ASCE 7-05,and 2005 NDS - Risk Category = II -Wind Speed = 100 mph, Exposure Category C -Ground Snow Load = 50 psf - MP1: Roof DL = 12.5 psf, Roof LL/SL= 30.5 psf(Non-PV Areas), Roof LL/SL = 19 psf(PV Areas) - MP2,3,4: Roof DL= 8 psf, Roof LL/SL= 30.5 psf(Non-PV Areas), Roof LL/SL = 19 psf(PV Areas) Note: Per IBC 1613.1; Seismic check is not required because Ss= 0.33365 < 0.4g and Seismic Design Category(SDC) = C< D On the above referenced project,the components of the structural roof framing impacted by the installation of the PV assembly have been reviewed. After this review it has been determined that the existing structure is adequate to withstand the applicable roof dead load, PV assembly load,and live/snow loads indicated in the design criteria above. I certify that the structural roof framing and the new attachments that directly support the gravity loading and wind uplift loading from PV modules have been reviewed and determined to meet or exceed structural strength requirements of the MA Res. Code, 8th Edition. Please contact me with any questions or concerns regarding this project. Sincerely, Yoo Jin Kim, P.E. Civil Engineer Main: 888.765.2489,x5743 email: ykim@solarcity.com 3055 Clearview Way San Mateo,CA 94402 T(650)638-1028 (888)SOL-CITY F(650)638-1029 solarcity.com lq1'- 1 1 �1t- :rs• .V' ,?]tt'.1 I lel 1'4; , re6 .. _ i, ••are h .'7�'r •-} e.• ;... _ l._ r.-LCH 1L`:l.Jn•R4¢I' A:. ...-:eA 11•,.' ::,4-� � r ... ., a ..•I'. r.. ..t 10.03.2014 d`�as • TM Version#39.1 � �����,�M,� SleekMount PV System . y Structural Design Software PROJECT INFORMATION &TABLE OF CONTENTS Project Name: Ferres Residence AHJ: North Andover Job Number: 0181110 Building Code: MA Res. Code, 8th Edition Customer Name: Ferres,Judy Based On: IRC 2009/IBC 2009 Address: 31 Oxbow Cir ASCE Code: ASCE 7-05 City/State: North Andover, MA Risk Category: II Zip Code 01845 Upgrades Req'd? No Latitude/Longitude: 42.635360 -71.080334 Stamp Req'd? Yes SC Office: Wilmington PV Designer: Lalita Nayagam Calculations: Brad Taylor EOR: Yoo Jin Kim P.E. Certification Letter 1 Project Information, Table Of Contents, &Vicinity Map 2 Structure Analysis (Loading Summary and Member Check) 3 Hardware Design (PV System Assembly) 4 Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.33365 < 0.4g and Seismic Design Category(SDC) = C < D 1/2-MILE VICINITY MAP 1C4 Woodland li4 DQJ (R931CM ssGIS, Commonwealthof • ' USDA Agency Farm Service 31 Oxbow Cir, North Andover, MA 01845 Latitude:42.63536,Longitude: -71.080334, Exposure Category:C LOAD ITEMIZATION - MPI PV System Load PV Module Weight(psf) 2.5 psf Hardware Assembly Weight 0.5 psf PV System Weight s 3.0 Psf Roof Dead Load Material Load Roof Category Description MPI Roofing Type_ _ Comp Roof ( 1 Layers) 2.5 psf Re-Roof to 1 Layer of Comp? No Underlayment r� Roofing Paper _ _W 0.5 psf Plywood Sheathing Yes _ 1.5 psf Board Sheathing _ None Rafter Size and Spacing _ 2 x 8 @16 in.O.C. 2.3 psf Vaulted Ceiling _ Y Yes � 4.7 psf Miscellaneous Miscellaneous Items 1.0 sf Total Roof Dead Load 12.5 psf(MP1) 12.5 Psf Reduced Roof LL Non-PV Areas Value ASCE 7-05 Roof Live Load Lo 20.0 psf Table 4-1 Member Tributary Area At < 200 sf Roof Slope 9/12 Tributary Area Reduction Rl 1 Section 4.9 Sloped Roof Reduction Rz _ 0.775 _ Section 4.9 Reduced Roof Live Load Y Lr Lr= Lo(RI)(RZ) _ E cation 4-2 Reduced Roof Live Load Lr 15.5 Psf(MPI) 15.5 sf Reduced Ground/Roof Live/Snow Loads Code Ground Snow Load p9 50.0 psf_ ASCE Table 7-1 Snow Load Reductions Allowed? Yes Effective Roof Slope _ 350 I Horiz. Distance from Eve to Ridge W 16.5 ft Snow Importance Factor IS 1.0 Table 1.5-2 Snow Exposure Factor Ce Partially 0 posed Table 7-2 Snow Thermal Factor ®� Ct All structures except 1 s0 indicated otherwise Table 7-3 Minimum Flat Roof Snow Load (w/ Rain-on-Snow Surcharge) Pf-min 35.0 psf 7.3.4&7.10 Flat Roof Snow Load Pf Pf= 0.7(Ce) (Ct)(I) pg; pf>_ pf-min Eq: 7.3-1 35.0 psf 70% ASCE Design Sloped Roof Snow Load Over Surrounding Roof Surface Condition of Surrounding All Other Surfaces Roof CS-roof 0.9 Figure 7-2 Design Roof Snow Load Over P:-roof= (Cs-roof)Pf ASCE Eq: 7.4-1 SurroundingRoof PS 1O°f 30.7 psf 61% ASCE Design Sloped Roof Snow Load Over PV Modules Surface Condition of PV ModulesUnobstructed Slippery Surfaces °° 0.5 Figure 7-2 Design Snow Load Over PV PS_ „= (CS-P.)Pf ASCE Eq: 7.4-1 Modules PS-Pv 18.9 Psf 38% COMPANY PROJECT WoodWorks® SORWAREIOR WOOD DIF" Oct. 3, 2014 13:36 MP1.wwb Design Check Calculation Sheet WoodWorks Sizer 10.1 Loads: Load Type Distribution Pat- Location [ft] Magnitude Unit tern Start End Start End DL Dead Full Area No 12.50 (16.0) * psf PV LOAD Dead Partial Area No 5.00 10.42 3.00 (16.0) * psf ROOF .SL 1 Snow Partial Area Yes 0.00 5.00 30.70 (16.0) * psf ROOF SL 2 Snow Partial Area Yes 10.42 15.67 30.70 (16.0) * psf PV SL Snow Partial Area Yes 5.00 10.42 1 18.90 (16.0) * ,psf *Tributary Width (in) Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) : 20'-4.5" 0' 0'-10" 15'-8" Unfactored: Dead 187 171 Snow 293 264 Factored: Total 479 435 Bearing: F'theta 567 567 Capacity Joist 3293 2974 Supports 2789 - Anal/Des Joist 0.15 0.15 Support 0.17 - Load comb #2 #4 Length 3.50 3 .50 Min req'd 0.60** 0.51 Cb 1.11 1.00 Cb min 1.62 1.00 Cb support 1.25 - Fcp sup 425 - "Minimum bearing length governed by the required width of the supporting member. Bearing for wall supports is perpendicular-to-grain bearing on top plate. No stud design included. MPI Lumber-soft, S-P-F, No.1/No.2, 2x8 (1-1/2"x7-1/4") Supports: 1 - Lumber Stud Wall, S-P-F Stud; 2 - Hanger; Roof joist spaced at 16.0" c/c; Total length: 20'-4.5"; Pitch: 9/12; Lateral support: top= full, bottom=at supports; Repetitive factor: applied where permitted (refer to online help); WARNING: Member length exceeds typical stock length of 18.0 [ft] WoodWOrks® Sizer SOFTWARE FOR WOOD DESIGN MP1.wwb WoodWorks®Sizer 10.1 Page 2 Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2012 : Criterion Analysis Value Design Value Analysis/Design Shear fv = 44 Fv' = 155 fv/Fv' = 0.28 Bending(+) fb = 1385 Fb' = 1389 fb/Fb' = 1.00 Bending(-) fb = 20 Fb' = 538 fb/Fb' = 0.04 Live Defl'n 0.82 = L/270 1.24 = L/180 0.66 Total Defl'n 1.42 = L/156 1.85 = L/120 0.77 Additional Data: FACTORS: F/E(psi)CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC# Fv' 135 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 2 Fb'+ 875 1.15 1.00 1.00 1.000 1.200 1.00 1.15 1.00 1.00 - 4 Fb' - 875 1.15 1.00 1.00 0.388 1.200 1.00 1.15 1.00 1.00 - 2 Fcp' 425 - 1.00 1.00 - - - - 1.00 1.00 - - E' 1.4 million 1.00 1.00 - - - - 1.00 1.00 - 4 Emin' 0.51 million 1.00 1.00 - - - - 1.00 1.00 - 4 CRITICAL LOAD COMBINATIONS: Shear . : LC #2 = D+S, V = 344, V design = 319 lbs Bending(+) : LC #4 = D+S (pattern: sS) , M = 1517 lbs-ft Bending(-) : LC #2 = D+S, M = 21 lbs-ft Deflection: LC #4 = (live) LC #4 = (total) D=dead L=construction S=snow W=wind I=impact Lr=roof constr. Lc=concentrated All LC's are listed in the Analysis output Load Patterns: s=S/2, X=L+S or L+Lr, _=no pattern load in this span Load combinations: ASCE 7-10 / IBC 2012 CALCULATIONS: Deflection: EI = 67e06 lb-in2 "Live" deflection = Deflection from all non-dead loads (live, wind, snow...) Total Deflection = 1.00 (Dead Load Deflection) + Live Load Deflection. Bearing: Allowable bearing at an angle F'theta calculated for each support as per NDS 3 .10.3 Design Notes: 1. WoodWorks analysis and design are in accordance with the ICC International Building Code (IBC 2012), the National Design Specification (NDS 2012), and NDS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Continuous or Cantilevered Beams: NDS Clause 4.2.5.5 requires that normal grading provisions be extended to the middle 2/3 of 2 span beams and to the full length of cantilevers and other spans. 4. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. 5. SLOPED BEAMS: level bearing is required for all sloped beams. 6. The critical deflection value has been determined using maximum back-span deflection. Cantilever deflections do not govern design. i CALCULATION OF DESIGN WIND LOADS - MP1 _ Mounting Plane Information Roofing Material Comp Roof PV System Type SolarCity SleekMountTm Spanning Vents No Standoff Attachment Hardware Com Mount T e C Roof Slope 350 Rafter Spacing 16"O.C. Framing Type Direction Y-Y Rafters Purlin Spacing X-X Purlins Only NA Tile Reveal Tile Roofs Only NA Tile Attachment System Tile Roofs Only_ _NA Standing Seam Spacinq SM Seam Only NA Wind Design Criteria Wind Design Code ASCE-7-05 Wind Design Method _ Partially/Fully Enclosed Method Basic Wind Speed V 100100 moh Fig. 6-1 Exposure Category _. __C_ _ _Section 6.5.6.3 Roof Style Gable Roof Fig.6-11B/C/D-14A/B Mean Roof Hei ht h 25 ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ _ 0.95 Table 6-3 Topographic Factor Kg 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 1.0 Table 6-1 Velocity Pressure qh qh = 0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 20.6 psf Wind Pressure Ext. Pressure Coefficient U GC -0.95 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient Down GC 0.88 Fig.6-11B/C/D-14A/B Design Wind Pressure p p = qh(GC) Equation 6-22 Wind Pressure U -19.6 psf Wind Pressure Down 18.0 Psf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 64" 39" Max Allowable Cantilever Landscape ___24" __ _ NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib_ 17 sf_ PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T-actual -311 lbs _ Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 1 62.2% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait48" 64" Max Allowable Cantilever Portrait _ a 20" __ _ NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib _ _21 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T-actual _ -389 lbs Uplift Capacity of Standoff T-allow_ 500 lbs Standoff Demand/Capacity I DCR 1 77.9% LOAD ITEMIZATION - MP213, 4 PV System Load PV Module Weight(psf) _ 2.5 psf Hardware Assembly Weight 0.5 psf PV System Weight s 3.0 psf Roof Dead Load Material Load Roof Category Description MP2, 3,4 Roofing Type - J _ _Comp Roof T ( 1 Layers) 2.5 psf Re-Roof to 1 Layer of Comp? No Underlayment __ �_ Roofing Paper 0.5,psf Plywood Sheathing Yes 1.5 psf Board Sheathing _ None Rafter Size and Spacing 2 x 8 @ 16 in. O.C. 2_._3 psf Vaulted Ceiling _ a No Miscellaneous Miscellaneous Items 1.2 psf Total Roof Dead Load 8 psf(MP2,3 4 8.0 psf Reduced Roof LL Non-PV Areas Value ASCE 7-05 Roof Live Load _ Lo 20.0 psf _ Table 4-1 Member Tributary Area _ At < 200 sf Roof Slope _ 9/12 _ Tributary Area Reduction Ri _ 1 w Section 4.9 Sloped Roof Reduction Rz 0.775 Section 4.9 Reduced Roof Live Load Lr L,= L.(Ri)(RZ) Equation 4-2 Reduced Roof Live Load Lr 15.5 psf MP2 3 4 15.5 Psf Reduced Ground/Roof Live/Snow Loads Code Ground Snow Load p9 50.0 psf ASCE Table 7-1 Snow Load Reductions Allowed? Yes Effective Roof Slope _ 350 Horiz. Distance from Eve to Ridge _-_ W _ _ _ 19.0 ft Snow Importance Factor IS 1.0 Table 1.5-2 Snow Exposure Factor Ce Partially Exposed _ Table 7-2 - — - 1.0 Snow Thermal Factor Ct All structures except as indicated otherwise Table 7-3 Minimum Flat Roof Snow Load (w/ 1.0_ Rain-on-Snow Surcharge) Pf-moo 35.0 psf 7.3.4&7.10 Flat Roof Snow Load pf pf= 0.7(Ce) (Cr) (I) pg; pf> pf-min Eq: 7.3-1 35.0 Psf 70% ASCE Design Sloped Roof Snow Load Over Surroundinq Roof Surface Condition of Surrounding All Other Surfaces Roof CS goof Figure 7-2 0.9 Design Roof Snow Load Over P:-roof= (Cs-roof)Pf ASCE Eq: 7.4-1 SurroundingRoof Ps-roof 30.7 Psf 61% ASCE Design Slo ed Roof Snow Load Over PV Modules Surface Condition of PV Modules CS_p„ Unobstructed Slippery Surfaces Figure 7-2 0.5 Design Snow Load Over PV PS_ = (CS- „)Pf ASCE Eq: 7.4-1 Modules PS°" 18.9 Psf 38% COMPANY PROJECT WoodWorks@ Oct. 3, 2014 13:37 MP2, 3, 4.wwb Design Check Calculation Sheet WoodWorks Sizer 10.1 Loads: Load Type Distribution Pat- Location [ft] Magnitude Unit tern Start End Start End DL Dead Full Area No 12.50 (16.0) * psf PV LOAD Dead Partial Area No 1.33 14.75 3.00 (16.0) * psf ROOF SL 1 Snow Partial Area Yes 0.00 1.33 30.70 (16.0) * psf ROOF SL 2 Snow Partial Area Yes 14.75 15.67 30.70 (16.0) * psf PV SL Snow Partial Area Yes 1.33 14.75 18.90 (16.0) * ,psf *Tributary Width (in) Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) 20'-3.2,1 0' 0'-10" 15'-7" Unfactored: Dead 206 191 Snow 229 202 Factored: Total 434 392 Bearing: F'theta 567 567 Capacity Joist 3293 2974 Supports 2789 - Anal/Des Joist 0.13 0.13 Support 0.16 - Load comb #2 #4 Length 3.50 3 .50 Min req'd 0.55** 0.50* Cb 1.11 1.00 Cb min 1.69 1.00 Cb support 1.25 - Fcp sup 425 - *Minimum bearing length setting used: 1/2"for end supports "Minimum bearing length governed by the required width of the supporting member. Bearing for wall supports is perpendicular-to-grain bearing on top plate. No stud design included. MP2, 3, 4 Lumber-soft, S-P-F, No.1/No.2, 2x8 (1-1/2"x7-1/4") Supports: 1 - Lumber Stud Wall, S-P-F Stud; 2 - Hanger; Roof joist spaced at 16.0" c/c; Total length: 20'-3.2"; Pitch: 9/12; Lateral support: top=full, bottom= at supports; Repetitive factor: applied where permitted (refer to online help); WARNING: Member length exceeds typical stock length of 18.0 [ft] WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN i MP2, 3,4.wwb WoodWorks®Sizer 10.1 Page 2 i Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2012 : Criterion Analysis Value Design Value Analysis/Design Shear fv = 39 Fv' = 155 fv/Fv' = 0.25 Bending(+) fb = 1263 Fb' = 1389 fb/Fb' = 0.91 Bending(-) fb = 20 Fb' = 541 fb/Fb' = 0.04 Live Defl'n 0.63 = L/351 1.23 = L/180 0.51 Total Defl 'n 1.27 = L/174 1.84 = L/120 0.69 Additional Data: FACTORS: F/E(psi)CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC# Fv' 135 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 2 Fb'+ 875 1.15 1.00 1.00 1.000 1.200 1.00 1.15 1.00 1.00 - 4 Fb' - 875 1.15 1.00 1.00 0.389 1.200 1.00 1.15 1.00 1.00 - 2 Fcp' 425 - 1.00 1.00 - - - - 1.00 1.00 - - E' 1.4 million 1.00 1.00 - - - - 1.00 1.00 - 4 Emin' 0.51 million 1.00 1.00 - - - - 1.00 1.00 - 4 CRITICAL LOAD COMBINATIONS: Shear : LC #2 = D+S, V = 307, V design = 282 lbs Bending(+) : LC #4 = D+S (pattern: sS) , M = 1383 lbs-ft Bending(-) : LC #2 = D+S, M = 21 lbs-ft Deflection: LC #4 = (live) LC #4 = (total) D=dead L=construction S=snow W=wind I=impact Lr=roof constr. Lc=concentrated All LC's are listed in the Analysis output Load Patterns: s=S/2, X=L+S or L+Lr, _=no pattern load in this span Load combinations: ASCE 7-10 / IBC 2012 CALCULATIONS: Deflection: EI = 67e06 lb-in2 "Live" deflection = Deflection from all non-dead loads (live, wind, snow...) Total Deflection = 1.00 (Dead Load Deflection) + Live Load Deflection. Bearing: Allowable bearing at an angle F'theta calculated for each support as per NDS 3.10.3 Design Notes: 1. WoodWorks analysis and design are in accordance with the ICC International Building Code (IBC 2012), the National Design Specification (NDS 2012), and NDS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Continuous or Cantilevered Beams: NDS Clause 4.2.5.5 requires that normal grading provisions be extended to the middle 2/3 of 2 span beams and to the full length of cantilevers and other spans. 4. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. 5. SLOPED BEAMS: level bearing is required for all sloped beams. 6. The critical deflection value has been determined using maximum back-span deflection. Cantilever deflections do not govern design. .CALCULATION OF DESIGN WIND LOADS - MP2, 3, 4 _ Mounting Plane Information Roofing Material Comp Roof PV System Type SolarCity SleekMountT"' Spanning Vents No Standoff Attachment Hardware Comp Mount Type C Roof Slope 350 Rafter Spacing - _16"O.C. Framing Type Direction Y-Y Rafters Purlin Spacing X-X Purlins Only_ --NA Tile Reveal Tile Roofs Only NA Tile Attachment System Tile Roofs Only NA IStanding Seam Spacing SM Seam Only NA Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method Partially/Fully--Enclosed Method _ Basic Wind Speed V 100 mph Fig. 6-1 Exposure Category C Section 6.5.6.3 Roof Style Gable Roof Fig.6-116/C/D-14A/13 Mean Roof Height I h 25 ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ _ 0.95 Table 6-3 Topographic Factor Krt _ - 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 1.0 Table 6-1 VelocityPressure qh = 0.00256(Kz)(Kzt)(Kd)(V^2)(I) qn 20.6 sf Equation 6-15 Wind Pressure Ext. Pressure Coefficient U GC -0.95 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient Down G 0.88 Fig.6-11B/C/D-14A/B Design Wind Pressure p p = qh(GC ) Equation 6-22 Wind Pressure U -19.6 psf Wind Pressure Down 18.0 Psf ;ALLOWABLE STANDOFF SPACINGS _ X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 64" 39" Max Allowable Cantilever Landscape___ _. _ 24" _ __ _ NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 17 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T-actual' _-311 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity I DCR 1 62.2% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 48" 64" Max Allowable Cantilever Portrait --20" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area. Trib _ _ 21 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T-actual ? _-_389_lbs Uplift Capacity of Standoff T-allow _500 Ibs Standoff Demand Ca aci DCR 77.9% DocuSign Envelope ID:3C455077-EA5C-45F3-A52B-E3D7336C1D4C 22. NOTICE OF RIGHT TO CANCEL. I have read this Power Purchase Agreement and the Exhibits in their YOU MAY CANCEL THIS CONTRACT AT ANY TIME PRIOR TO entirety and I acknowledge that I have received a complete copy of this MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE DATE Power Purchase Agreement. YOU SIGN THIS CONTRACT. SEE EXHIBIT 1,THE ATTACHED NOTICE OF CANCELLATION FORM FOR AN Customer's Name:Judy Ferres EXPLANATION OF THIS RIGHT. D-U8 pp„ddy, 23. ADDITIONAL RIGHTS TO CANCEL. Signature: .JU _y F-e- s IN ADDITION TO ANY RIGHTS YOU MAY HAVE TO CANCEL THIS PPA UNDER SECTION 22,YOU MAY ALSO CANCEL Date: gy��1j THIS PPA AT NO COST AT ANY TIME PRIOR TO COMMENCEMENT OF CONSTRUCTION ON YOUR HOME. 24. Pricing The pricing in this PPA is valid for 30 days after 9/27/2014. If you Customer's Name:. Jack Ferres don't sign this PPA and return it to us on or prior to 30 days after °aUWg'"dW. 9/27/2014,SolarCity reserves the right to reject this PPA unless Signature: .Ja('( Ferrel__ you agree to our then current pricing. cwirww_ Date: "9/27/203'4-7 "SQlarCity. Power Purchase Agreement S©LAiRCITY APPROVED Signature: ` LYNDON RIVE,CEO (PPA) Power Purchase Agreement .yk1ls Date: 9/27/2014 Solar Power Purchase Agreement version 8.1.0 300414 a ,� DocuSign Envelope ID:3C455077-EA5C-45F3-A528-E3D7336C1 D4C ,; SolarCity. Power Purchase Agreement Here are the key terms of your SolarCity Power Purchase Agreement Date:927/14 0 11000 20years System installation cost Electricity rate per kWh Agreement term Our Promises to You • We insure,maintain,and repair the System (including the inverter)at no additional cost to you,as specified in the agreement. • We provide 24/7 web-enabled monitoring at no additional cost to you,as specified in the agreement. • We warranty your roof against leaks and restore your roof at the end of the agreement,as specified in the agreement. • The rate you pay for electricity,exclusive of taxes,will never increase by more than 2.90%per year. • The pricing in this PPA is valid for 30 days after 9/27/2014. • We are confident that we deliver excellent value and customer service. As a result, you are free to cancel anytime at no charge prior to construction on your home. Estimated First Year Production 13,719 kWh Customer's Name & Service Address Exactly as it appears on the utility bill Customer Name and Address Customer Name Installation Location Judy Ferres Jack Ferres 31 Oxbow Cir 31 Oxbow Cir North Andover, MA 01845 North Andover, MA 01845 Options for System purchase and transfer: Options at the end of the 20 year term: • If you move,you may transfer this agreement to the purchaser of your • SolarCity will remove the System at no cost to you. Home,as specified in the agreement. • You can upgrade to a new System with the latest solar • At certain times,as specified in the agreement,you may purchase the technology under a new contract. System. . You may purchase the System from SolarCity for its fair • These options apply during the 20 year term of our agreement and not market value as specified in the agreement. beyond that term. • You may renew this agreement for up to ten(10)years in two(2)five(5)year increments. 3055 CLEARVIEW WAY, SAN MATEO, CA 94402 888.SOL.CITY 1888.765.2489 1 SOLARCITY.COM MA HIC 168572/EL-1136MR Document Generated on 9/27/2014 300414 A The Commonwealth of Massachusetts Department of Industrial Accidents Office of Investigations ' 1 Congress Street,Suite 100 Boston,MA 02114-2017 t www.mass.gov/dia Workers'Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Analicant Information Please Print Legibiy Name(Business/Organization/Individual): SOLARCITY CORP Address:3055 CLEARVIEW WAY City/State/Zip:SAN MATEO, CA 94402 phone #:888'765-2489 Are you an employer?Check the appropriate box: Type of project(required): 1.0 I am a employer with 5000 4. ❑ I am a general contractor and I 6. ❑New construction employees(full and/or part-time)." have hired the sub-contractors 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have g. ❑ Demolition working for me in any capacity. employees and have workers' 9. ❑ Building addition [No workers' comp. insurance comp. insurance.$ required.] 5. ❑ We are a corporation and its 10.❑ Electrical repairs or additions 3.❑ 1 am a homeowner doing all work officers have exercised their 1 LE] Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs insurance required.] t c. 152,§1(4),and we have no SOLAR/PV employees. [No workers' 13.❑Other comp. insurance required.] *Any applicant that checks box#I must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they arc doing all work and then hire outside contractors must submit a new affidavit indicating such. $Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is lite policy and job rile Information. Insurance Company Name:LIBERTY MUTUAL INSURANCE COMPANY Policy#or Self-ins. Lic. #:WA7-66D-066265-024 Expiration Date:08/01/2015 Job Site Address: 31 n bow C►.r- City/State/Zip:11)CH—ll 6,2dQL�er Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required-under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby cerl6o nutlet the pains irnd penalties ajperjrrry flintttlite hr rmation provided above is true and correct. Signature: ` l)at c:: — Phone#• Of)'dcial«se only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2. Building Department 3.City/Town Clerk 4. Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: DATE(MMIDDIYYYY) A`ORv CERTIFICATE OF LIABILITY INSURANCE 0812912014 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the policy(les)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTA T MARSH RISK 8 INSURANCE SERVICES NAME: 345 CALIFORNIA STREET,SURE 1300 IAICNN•Extl (AIC.No): _ CALIFORNIA LICENSE NO.0437153 E-MAIL SAN FRANCISCO,CA 94104 ADDRESS: INSURERS)AFFORDING COVERAGE NAIC N 998301-STND-GAWUE-14.15 INSURER A:Liberty Mutual Fire Insurance Company 16586 INSUREDLiberty Insurance Corporation 42404 Ph(650)963.5100 INSURER e SolarCity Corporation INSURER C;NIA NIA 3055 Ciearview Way INSURER D: San Mateo,CA 94402 -- "— INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: SEA-002440269-02 REVISION NUMBER:4 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS. EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS_. LLICYEXP TYPE OF INSURANCE JNgR WVn UB POLICY NUMBER MPMIDDY EFF MMIDD/YYY _ LIMITS A GENERAL LIABILITY T82-861-066265.014 09101/2014 09/01/2015 EACH OCCURRENCE $ 1,000,000 X DAMA E TO RENTED 100,000 COMMERCIAL GENERAL LIABILITY PREMISES(Ea 2m nonce) $ _ CLAIMS-MADE M OCCUR MED EXP(Any oneperson) $ 10,000 PERSONAL&ADV INJURY $ _ 1'000'000 _ _GENERAL AGGREGATE $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OP AGG $ 2,000,000 X1 POLICY I X PRO• LOC Deductible $ 25,000 A AUTOMOBILE LIABILITY AS2MI-066265.044 09/01/2014 09101/2015 COMBINED SINGLE LIMIT 1 Q�� _ Ea accident) x ANY AUTO BODILY INJURY(Per person) S ALL OWNED SCHEDULED BODILY INJURY(Per accident) $ X AUTOS AUTX NON OWNED PROPERTY DAMAGE $ HIRED AUTOS _ AUTOS (Per s-derit) X Phys.Damage COMPICOLL DED: S $1,0001$1,000 UMBRELLA LIAS OCCUR EACH OCCURRENCE $ _ EXCESS UAB CLAIMS-MADE AGGREGATE S DEO RETENTION$ $ B WORKERS COMPENSATION WA7-66D-066265-024 09/0112014 09/01/2015X WC ST�U-ITS 1 ER B -_ AND EMPLOYERS'LIABILITY WC7-661- 265-034(WI) 09/01/2014 09/01/2015 E L EACH ACCIDENT $ 1,000,000 ANY PROPRIETOR/PARTNER/EXECUTIVE YIN 066 _ B OFFICERIMEMBER EXCLUDED? N NIA DEDUCTIBLE:!350 WC DEDU : ,000' {Mandatory In NH) E L.DISEASE•EA EMPLOYEE $ 1'000,000 If yes,describe under 100,0DQ DESCRIPTION OF OPERATIONS below E L DISEASE-POLICY LIMIT S DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (Attach ACORD 101,Additional Remarks Schedule,if more space Is required) Evidence of Insurance. CERTIFICATE HOLDER CANCELLATION SolarCity Corporation SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 3055 Clearview Way THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN San Mateo,CA 94402 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh Risk&Insurance Services Charles Marmolejo ��— O 1988-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010105) The ACORD name and logo are registered marks of ACORD ' I Office of Consumer Affairs and Business Regulation eJ r t it = 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 168572 Type: Supplement Card SOLARCITY CORPORATION Expiration: 3/8/2015 CRAIG ELLS 24 ST. MARTIN STREET BLD 2 UNIT 11 - - - - -- - - ------ MARLBOROUGH, MA 01752 Update Address and return card.Mark reason for change. sc�+ c• 20M osr+ EI Address n Renewal n Employment CI Lost Card Office of Consumer Affairs&Business Regulation License or registration valid for individul use only 1 ; ME IMPROVEMENT CONTRACTOR before the expiration date. If found return to: z�i'` f f'4St Office of Consumer Affairs and Business Regulation .t_., Registration: 168572 Typc 10 Park Plaza-Suite 5170 Expiration: 3/8/2015 Supplement :ard Boston,MA 02116 SOLARCITY CORPORATION CRAIG ELLS 24 ST MARTIN STREET BLD 2UN1 KIA&LBOROUGH,MA 01752 Undersecretary Not v lid without signature Massachusetts •Department of A-,'JI+C Safety Board of Building Reguiat+ons ard 5tanuaras :.-cense CS-107663 4 CRAIG ELLS 206 BAKER STREET Keene NH 03431 I r+++anti++c mrr 08/29/2017 ' I CTG foijefil0jettleirtAll to t"i jaC'Il vi e//' Office of Consumer Affairs-and Business Regulation N 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration P g Registration: 168572 Type: Supplement Card SOLAR CITY CORPORATION Expiration: 3/8/2015 ASTRID BLANCO _- -- 24 ST. MARTIN STREET BLD 2 UNIT 11 - - MARLBOROUGH, MA 01752 Update Address and return card.Mark reason for change. SCA 1 e 20M-05,11 Address Renewal [:] Employment E] Lost Card _==�flice of Consumer Affairs&Business Regulation License or registration valid for individul use only M bME IMPROVEMENT CONTRACTOR before the expiration date. If found return to: j Office of Consumer Affairs and Business Regulation �.� ;Registration: 168572 Type: 10 Park Plaza-Suite 5170 "= ' Expiration: 3/8/2015 Supplement Card Boston,MA 02116 SOLAR CITY CORPORATION ASTRID BLANCO 94mic 24 ST MARTIN STREET BLD 2UNI - _ — TAAALBOROUGH,MA 01752 Undersecretary Not valid without signature t ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN ECC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HOG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. 1 CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) ' NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING P01 POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 STRUCTURAL VIEWS LICENSE GENERAL NOTES PV5 UPLIFT PV6 CALCULATIONS THREE LINEDIAG AM GEN #168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION Cutsheets Attached ELEC 1136 MR OF THE MA STATE BUILDING CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: ZEP SOLAR AHJ: North Andover REV BY DATE COMMENTS REV A NAME DATE COMMENTS * * * * UTILITY: National Grid USA (Massachusetts Electric) i JB-01 81110 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBERFERRES, JUDY FERRES RESIDENCE Y 9 \`I1,�OI���'� CONTAINED SHALL NOT BE USED FOR THE Lallta NO a Om NORBENEFIT OF SHALL ITNBEN DISCLOSED IN MOLE ORT SOLARCITY CIN MOUNTING SYSTEM: 31 OXBOW CIR 17.34 KW PV ARRAY Arq PART TO OTHERS OUTSIDE THE RECIPIENTS Comp Mount Type C ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: NORTH ANDOVER, MA 01845 24 St. Martin Drive, Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (68) CANADIAN SOLAR # CS6P-255PX R� DATE Marlborough, MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: T: (650)638-1026 F: (650)638-1029 PERMISSION of soLARaTY INC. SOLAREDGE SE760OA—USOOOSNR2 9786888589 COVER SHEET PV 1 10/3/2014 (BSB)-SOL-CITY(765-2489) www.solarcity.com _ PITCH: 35 ARRAY PITCH:35 MP1 AZIMUTH: 103 ARRAY AZIMUTH: 103 o MATERIAL: Comp Shingle STORY: 2 Stories. n o PITCH: 35 ARRAY PITCH:35 MP2 AZIMUTH:283 ARRAY AZIMUTH: 283 MATERIAL: Comp Shingle STORY: 2 Stories PITCH: 35 ARRAY PITCH:35 MP3 AZIMUTH: 110 ARRAY AZIMUTH: 110 MATERIAL: Comp Shingle STORY. 2 Stories C PITCH: 35 ARRAY PITCH:35 MP4 AZIMUTH:290 ARRAY AZIMUTH: 290 MATERIAL: Comp Shingle STORY: 2 Stories i7 M a Cp LEGEND ® 0 (E) UTILITY METER & WARNING LABEL INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS DC DC DISCONNECT & WARNING LABELS B A GF © AC DISCONNECT & WARNING LABELS y.�Front House O DC JUNCTION/COMBINER BOX & LABELS Of YOC! JIN K H Q DISTRIBUTION PANEL & LABELS No.4 LG LOAD CENTER & WARNING LABELS ° E O Digitalloo Jin Kim DEDICATED PV SYSTEM METER y Date: 20 4.10.03 14:50:44 O STANDOFF LOCATIONS -07�00� CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR M O r AC T,- GATE/FENCE N l E._�l r p Q HEAT PRODUCING VENTS ARE RED 1. '1 INTERIOR EQUIPMENT IS DASHED D O L� Inv Inv SITE PLAN " Lc Scale: 3/32" = 1' E 01' 10' 21' W S CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: JB-0181110 00 CONTAINED SHALL NOT USED FOR THE FERRES, JUDY FERRES RESIDENCE Lalita Nayogam �;;;SO�a�C�t�/ BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �.,, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 31 OXBOW CIR 17.34 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH , -THE SALE AND USE OF THE RESPECTIVE (68) CANADIAN SOLAR # CS6P-255PX 24 St Martin Drive Building 2, unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEET' REV. DATE' L (650)Marlborough,36-102F: (6A1752 636-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE760OA—USOOOSNR2 9786888589 SITE PLAN PV 2 10/3/2014 (see)-SOL-CITY(765-2489) www.solarcity.com 0 (E) 2x4 (E) 1x8 E) 2x8 2x4 S1 S1 4" 0 14'-9" 0 14'-10" (E) LBW (E) LBW SIDE VIEW OF MP2 NTS A SIDE VIEW OF MP1 NTS B MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 64" 24" STAGGERED LANDSCAPE 64" 24" STAGGERED PORTRAIT 48" 20" PORTRAIT 48" 20" RAFTER 2X8 @ 16"OC ROOF AZI 283 PITCH 35 STORIES:2 ARRAY AZI 283 PITCH 35 RAFTER 2X8 @ 16"OC ROOF AZI 103 PITCH 35 STORIES: 2 C.J. 2x10 @16"OC Comp Shingle ARRAY AZI 103 PITCH 35 C.J. 2x10 @16"OC Comp Shingle �tH� S1 S 1 Y00 JIN K Na.4 „ 0 12'-10" (E) LBW AL 0 12'-10" SIDE VIEW OF MP3 NTs Digitally igned by Yoo Jin Kim (E) LBW Date: 2014.10.03 14:50:51 -07'00' SIDE VIEW OF MP4 NTS. EI P3 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTESSCAPE 64" 24" STAGGERED RAIT 48" 20" 1 MP4 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES RAFTER 2x8 @ 16"OC ROOF AZI 110 PITCH 35 DORIES:2 LANDSCAPE 64" 24" STAGGERED ARRAY AZI 110 PITCH 35 C.J. 2x8 @16"OC Comp Shingle PORTRAIT 48" 20" RAFTER 2X8 @ 16"OC ROOF AZI 290 PITCH 35 STORIES: 2 ARRAY AZI 290 PITCH 35 C.J. 2x8 @16"OC Comp Shingle JB-0181110 00 PREMISE OWNER: DESCRIPTION: DESIGN: ■ CONFIDENTIAL THE INFORMATION HEREIN doh NUMBER FERRES, JUDY FERRES RESIDENCE y 9 ,',SolarC�t . CONTAINED SHALL NOT BE USED FOR THE LCIIItO NO Cl 0m �� BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: Ilk NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type c 31 OXBOW CIR 17.34 KW PV ARRAY PART IZ OTHERSC PT IN THE RECIPIENT'S MODULES. NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St. Martin Drive, Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (68) CANADIAN SOLAR # CS6P-255PX PAGE NAME SHEET: REV. DATE: Marlborough,MA 01752 SOLARgTY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T. (650)638-1028 F. (650)638-1029 PERMISSION OF SOLARq,Y INC. SOLAREDGE sE7sooA—us000sNR2 9786888589 STRUCTURAL VIEWS PV 3 10/3/2014 (8nB-sol.—CITY(765-2489) www.solarcity.com PV MODULE 5/16° BOLT WITH LOCK F INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. vtOF 4 2 SEAL PILOT HOLE WITH ZEP COMP MOUNT C �► ( ) ( ) POLYURETHANE SEAYoo AN ZEP FLASHING C (3) (3) INSERT FLASHING. K H No,4 (E) COMP. SHINGLE (4) PLACE MOUNT. (1) (E) ROOF DECKING (2) U INSTALL LAG BOLT WITH AL 5/16" DIA STAINLESS (5) (5) SEALING WASHER. Digital signed by Yoo Jin Kim STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH Date: 2014.10.03 14:50:59 WITH SEALING WASHER (6) BOLT & WASHERS. (2-1/2 EMBED, MIN) -07'00' (E) RAFTER S♦ J 11/�l Scale: 1 1/2" = 1' CONFIDENTIAL— THE INFORMATION HEREIN [INI B NUMBER: JB-01 81110 00 PREMISE OWNER. DESCRIPTION: DESIGN: . CONTAINED SHALL NOT E USED FOR THE FERRES, JUDY FERRES RESIDENCE Lalita Nayagam ':,,So�arC�t . k BENEFIT OF ANYONE EXCEPT SOLARCITY INC., UNTING SYSTEM: /�� NOR SHALL IT BE DISCLOSED IN WHOLE OR INomp Mount Type C 31 OXBOW CIR 17.34 KW PV ARRAY PART TO OTHERS OUTSIDE THE CONNECTION DULES: NORTH ANDOVER MA 01845 ORGANIZAl1ON, EXCEPT IN CONNEC11ON WITH , THE SALE AND USE OF THE RESPECTIVE 68) CANADIAN SOLAR # CS6P-255PX 24 St.Martin Drive, Building 2,Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE: Marlborough,MA 01752 PERMISSION OF SOLARCITY INC. ERTER' 9786888589 T. (650)638-1028 F: (650)638-1029 OLAREDGE SE7600A—USOOOSNR2 STRUCTURAL VIEWS PV 4 10/3/2014 (888)-SOL-CITY(765-2489) www.solareity.com UPLIFT CALCULATIONS SEE SEPARATE PACKET FOR STRUCTURAL CALCULATIONS. CONFlDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-01 81110 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: FERRES, JUDY FERRES RESIDENCE y 9 ,,,So�arCit . CONTAINED SHALL NOT BE USED FOR THE LOIIttI NCI O 4m �� BENEFlT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �..� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 31 OXBOW CIR 17.34 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St. Martin Drive, Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (68) CANADIAN SOLAR # CS6P-255PX PAGE NAME SHEET: REN DATE: Marlborough, MA 01752 SOLARCITY EQUIPMENT, WnHOUT THE WRITTEN INVERTER T. (650)638-1028 F. (650)638-1029 PERMISSION OF SOLARCITY INC. ISOLAREDGE # SE760OA-USOOOSNR2 9786888589 UPLIFT CALCULATIONS PV 5 10/3/2014 (888)_SOL-CITY(765-2469) rmr.solarcity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO TWO (N) GROUND Panel Number:G4040MB1200 Inv 1: DC Ungrounded INV 1 -0)SOLAREDGE 6000A-USOOOSNR2 q -(66)CANADIAN SOLAR # CS6P-255PX GEN #168572 ODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:12807069 Inv 2: DC Ungrounded Inverter, sODow, 2aov/2osv, 97.5 'w/Unifed Disco and ZB,RGM,AFCI PV Module; 255W," 234.3W PTC, Black Frame, MC4, ZEP Enabled ELEC 1136 MR Underground Service Entrance Tie-In: Supply Side Connection INV 2-(1)SOLAREDGE #SE760OA-USOOOSNRLpgE� Inverter, 760OW, 24OV, 97.574 w�ni' disceo and ZB, RGM, AFCI Voc: 37.4 Vpmax: 30.2 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL E 20OA/2P MAIN CIRCUIT BREAKER Inverter 1 (E) WIRING CUTLER-HAMMER BRYANT Disconnect CUTLER-HAMMER (N) 125A Load Center 20OA/2P 10 Disconnect 9 7 SOLAREDGE B BOA D SE6000A-US00OSNR2 C 35A/2P SolarCity A L1 zgov 1 2 - - - a L2 A Dc+ N 5 DC- N I 4(E) DS GND GND _ _ EGC/ ___ DC+ DC+ MP 2: 2x14� -, r-------------- GEC TN DG DC• I r---J I = I GND __ EGC--------------------------- - -'----- --EGC -- ---------- I ` .J --- 41 N I II Inverter 2 EGC/GEC 8 SOLAREDGE ' I i SE7600A-LIS000SNR2 I I I 40A/2P Lt zaov AD L2 TO 120/240V ; N 6 ❑ MP 1,2: 1x19 SINGLE PHASE ________________ _ EGC/ ___ DC+_ MP34: 1x19UTILITY SERVICE I I GEC IN DG --------- -- J GND -_ EGC--------------------------- - -,-----I I I I I PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Voc* = MAX VOC AT MIN TEMP POI (2)Ground Rod; 5/8' x 8', Copper B (I)CUTLER-HAMMER #DG223NRB A (1)SolarCAYT 4 STRING JUNCTION BOX -(2)ILSCO }IPC 4/0-2/0 Disconnect; 1DOA, 24OVac, Fusible, NEMA 3R AC 2x2 STRINGS, UNFUSED, GROUNDED DC Insulation Piercing Connector; Main 4/0-2, Tap 2/0-6 -(1)CUTLER- AMMER #DGIDDNB D Ground�Neutral Kit; 60-100A, General Duty(DG) PV (66)SOLAREDGE P30D-2NA4AZS (1)BRYANT#BR816L125RP -(I)CUTLER-HAMMER #DS16FK PowerBox ptimizer, 30OW, H4, DC to DC, ZEP Load Center, 125A, 120/24OV, NEMA 311 Gass R Fuse Kit -(1)CUTLER-HAMM #BR235 -(2)FERRAZ SHAWMUT#TR80R PV BACKFEED OCP nd (1)AWG #6, Solid Bare Copper Breaker, 35A72P, 2 Spaces Fuse; 80A, 250V, Gass RK5 -(1)Ground Rod; 5/8* x 8', Copper -(I)CUTLER-HAMM #BR240 Breaker, 4OA/2P, 2 Spaces C (1)CUTLER-HAMMER #DG323UR6 N ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION N0. 2, ADDITIONAL SUPPLY SIDE CONNECTION. DISCONNECTING MEANS SHALL BE SUITABLE Disconnect; 1DOA, 24OVac, Non-Fusible, NEMA 3R ( ) S AS SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. -(1)Ground�NAeMMEER #Dtral Kit; 1 OOA General Duty(DG) ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE � 1 AWG #4, THWN-2, Black 1 AWG#8, THWN-2, Black 1 AWG 18, THWN-2, Black Voc* =500 VDC Isc =30 ADC (2)AWG #10, PV WIRE, Black Voc* =500 VDC Isc =15 ADC OIsF (1)AWG#4, THWN-2, Red - O L`L(1)AWG#8, THWN-2, Red O (1)AWG #8, THWN-2, Red Vmp =350 VDC Imp=20.14 ADC O (1)AWG#6, Solid Bare Copper EGC Vmp =350 VDC Imp=10.07 ADC IL LL(1)AWG , THWN-2, White NEUTRAL Vmp =240 VAC Imp=57 AAC IIII LLLL(1)AWG 0, THWN-2, White NEUTRAL Vm 240 VAC Im 25 AAC 1 AWG 10, THWN-2, Green EGC -(1)Conduit Kit; 3 4 EMT #I P = P= �. #. . . . . . . . . . . . /�. . . . . . . . . . . . . . (1 AWG THWN-2,,Green EGC GEC- 1 Conduit Kit; 1 EMT - 1 AWG #8, THWN-2, Black Voc* 500 VDC Isc 30 ADC (2 AWG .#10,. . PV WIRE, Black Voc* =500 VDC Isc =15 ADC ). . .#8. . . . . . . . . . . . . . ./. . . .{.), (.), _ , #8,.THWN-2,.Green . . ECC/GEC,-(1)Conduit.Kit:.3/4'.EMT (1 AWG . . . . . . . . . . . . . . . . . . . . . . . . (1)AWG#4, THWN-2, Black 8 �(1)AWG#8, THWN-2, Black © (1)AWG #8, THWN-2, Red Vmp =350 VDC Imp=27.32 ADC 2 (1)AWG #6, Solid Bare Copper EGC Vmp =350 VDC Imp=10.07 ADC ®� , THWN-2, Red O L L(1)AWG#8, THWN-2, Red 1 AWG 10 TOWN-2, Green EGC. . . . (1)Conduit.Kit;.3 4' EMT cn (1)AWG#4 LLL�=_=CELL (1)AWG#4, THWN-2, White NEUTRAL Vmp =240 VAC Imp=57 AAC (1)AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=32 AAC (2)AWG#10, PV WIRE, Black Voc* =500 VDC Isc =15 ADC -(1)AWG#6,.Solid Bare,Copper. GEC. . . -(1)Conduit.Kit;.1'.EMT. . . . . . . . . . . . . . . . . . .-(1)AWG#8,.TFIWN-2,.Green . _ EGC/GEC (1)Conduit.Kit;.3/4'EMT. . . O (1)AWG #6, Solid Bare Copper EGC Vmp =350 VDC Imp=13.66 ADC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ®�(2)AWG #10, PV WIRE, Black VoC* =500 VDC Isc =15 ADC (1)AWG #6, Solid Bare Copper EGC Vmp =350 VDC Imp=13.66 ADC PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: JB-01 81110 00 Lalito NO 0 am So arCit CONTAINED SHALL NOT BE USED FOR THE FERRES, JUDY FERRES RESIDENCE y 9 BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: Vii,` NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 31 OXBOW CIR 17.34 KW PV ARRAY y. PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St. Martin Drive,Building Z Unit 11 -THE SALE AND USE OF THE RESPECTIVE (68) CANADIAN SOLAR # CS6P-255PX PACE NAME SHEET: REV DATE Marlborough, MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T. (650)638-1028 F: (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE # SE760OA-USOOOSNR2 9786888589 THREE LINE DIAGRAM PV 6 10/3/2014 (868)-SOL-CITY(765-2489) www.solarcity.com CAUTIO. N POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 31 Oxbow Cir INVERTER AND AC DC DISCONNECT DISCONNECT AC DISCONNECT ii ii ii ii INVERTER AND UTILITY DC DISCONNECT SERVICE r------------------------ — SOLAR PHOTOVOLTAIC ARRAY(§) J PH0T0`Y%TAIC BACK—FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL THE INFORMATION HEREIN JOB NUMBER: \\ CONTAINED SHALL NOT BE USED FOR THE JB-01 8 FERRES, JUDY FERRES RESIDENCE Lalita Nayagam ,;So�arCity. BENEFIT OF ANYONE EXCEPT SOLARgTY INC., MOUNTING SYSTEM: � + NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 31 OXBOW CIR 17.34 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS IMODULES:- NORTH ANDOVER MA 01845ORGANIZATION, EXCEPT IN CONNECTION WITH24 St. Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (68) CANADIAN SOLAR # CS6P-255PX PAGE NAME SHEET: REV DATE Marlborough, MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T. (650)838-1028 F: (650)638-1029 PERMISSION OF SOLARGTY INC. SOLAREDGE # SE7600A—USOOOSNR2 9786888589 SITE PLAN PLACARD PV 7 10/3/2014 (6B8)—SOL—CITY(765-2469) www.solarcity.com e�Edgees;g� ®D0� CS6P-235/240/245/250/255PX Neakt�fopgh _r CanadianSolar Electrical Data Black-framed STC CS6P-235P CS6P-240P CS6P-245P CS6P-250PXCS6P-255PX Temperature Characteristics Nominal Maximum Power(Pmax) 235W 240W 245W 25OW 255W _ _ Optimum Operating Voltage(Vmp) 29.8V 29.9V 30.OV 30.1V 30.2V Pmax -0.43%/°C Optimum Operating Current(Imp) 7.90A 8.03A 8.17A 8.30A 8.43A Temperature Coefficient Voc -0.34%/°C Open Circuit Voltage(Voc) 36.9V 37.OV 37.1V 37.2V 37.4V I Isc 10.065%/°C Black-framed Short Circuit Current(Isc) 8.46A 8.59A 8.74A 8.87A 9.00A Normal, Cell Temperature 45±2°C • Module Efficiency 14.61% 14.92% 15.23% 1 15.54% 15.85% Operating Temperature -40°C-+85°C Performance at Low Irradiance 23 5/240/245/2 1 Maximum System voltage 1000V IEC /600v UL Industry leading performance at low irradiation Maximum Series Fuse Rating 15A environment,+95.5%module efficiency from an Application Classification ClassA irradiance of 1000w/m'to 200w/m' Power Tolerance 0-+5W (AM 1.5,25•C) Next Generation Solar Module Under Standard Test Conditions(STC)ofirradiance of 1000W/m2,spectrum AM 1.5and cell temperature of25'C NewEdge,the next generation module designed for multiple Engineering Drawings NOCT CS6P-235P CS6P•240PXCS6P-245P CS6P-250PXCS6P-255PX types of mounting systems,offers customers the added Nominal Maximum Power(Pmax) 170W 174w 178w 181W 185w value of minimal system costs,aesthetic seamless Optimum Operating Voltage(Vmp) 27.2V 27.3V 27AV 27.5V 27.5V appearance,auto groundingand theft resistance. Optimum Operating Current(Imp) 6.27A 6.38A 6.49A 6.60A 6.71A Open Circuit Voltage(Voc) 33.9V 34.OV 34.1V 34.2V 34.4V The black-framed CS6P-PX is a robust 60 cell solar module Short Circuit Current(Isc) 6.86A 6.96A 7.08A 7.19A 7.29A Incorporating the groundbreaking Zap compatible frame. Under Normal Operating Cell Temperature,Irradiance of 800 W/m',spectrum AM I.S.ambient temperature 20'C, The specially designed frame allows for rail-free fast wind speed 1 m/s installation with the industry's most reliable grounding Mechanical Data system.The module uses high efficiency poly-crystalline Cell Type Poly-crystalline 156 x 156mm,2 or 3 Busbars Key Features silicon cells laminated with a white back sheet and framed Cell Arrangement 60(6 x 10) with black anodized aluminum-The black-framed CS6P-PX Dimensions 1638 x 982 x 40mm(64.5 x 38.7 x 1.57in) • Quick and easy to install - dramatically is the perfect choice for customers who are looking for a high weight 20.5kg(45.2 lbs) reduces installation time quality aesthetic module with lowest system cost. Front cover 3.2mm Tempered glass Frame Material Anodized aluminium alloy • Lower system costs - can cut rooftop Best Quality J-Box IP65,3 diodes installation costs in half Cable 4mm'(IEC)/l2AWG(UL),1000mm • 235 quality control points in module production connectors MC4 or MC4 Comparable I • Aesthetic seamless appearance - low profile EL screening to eliminate product defects Standard Packaging(Modules per Pallet) zapcs with auto leveling and alignment • Current binning to improve system performance • Accredited Salt mist resistant Module Pieces per container(40 ft.Container) 672pcs(40'HQ) • Built-in hyper-bonded grounding system - if it's I-V Curves (CS6P-255PX) mounted,it's grounded Best Warranty Insurance to • Theft resistant hardware • 25 years worldwide coverage • ; i o e f Section A-A • 100/e warranty term coverage I � { • Ultra-low parts count - 3 parts for the mounting • Providing third party bankruptcy rights ' 350 i and grounding system Non-cancellable Immediate coverage 15 • • Industry first comprehensive warranty insurance by o I AM Best rated leading insurance companies in the Insured by 3 world top insurance companies o „-o„-, world ' — _2 l v Comprehensive Certificates I —_~- -1 I_ • Industry leading plus only power tolerance:0-+5W . IEC 61215,IEC 61730, IEC61701 ED2,UL1703, f15 • Backward compatibility with all standard rooftop and CEC Listed,CE and MCS - 92 ground mounting systems • IS09001:2008:Quality Management System • ISO/TS16949:2009:The automotive quality Specifications included in this datasheet are subject to change without prior notice. • Backed By Our New 10125 Linear Power Warranty management system Plus our added 25 year insurance coverage • IS014001:2004:Standards for Environmental About Canadian Solar management system Canadian Solar Inc. is one of the world's largest solar Canadian Solar was founded in Canada in 2001 and was ioov. • QC080000 HSPM:The Certification for companies. As a leading vertical) inte rated successful) listed on NASDAQ Exchange (symbol: CSIQ in g0x Add P 9 Y- 9 Y 9 ( Y ) sacturing oi ed Value From,Warranty Hazardous Substances Regulations manusolar(acturer systems f ingots, Canadi nwafers, Solarcells, deliverssolar solar modules power capac ty of 2 05GW and cell manufacturing capacity of 1f3GW. • OHSAS 18001:2007 International standards for products of uncompromising quality to worldwide 80% occupational health and safety customers. Canadian Solar's world class team of °% REACH Compliance professionals works closely with our customers to 5 10 is 20 2s P provide them with solutions for all their solar needs. Headquarters 1545 Speedvale • •10 year product warranty on materials and workmanship $p•c' rr �;,een4'I •25 year linear power output warranty 2550 • D www.canadiansolar.com EN-Rev 10.17 Copyrlghl 6 2012 Canadian Solar Inc. CAUTIO. N POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 31 Oxbow Cir INVERTER AND AC DC DISCONNECT DISCONNECT AC DISCONNECT l . l l l l l l INVERTER AND UTILITY DC DISCONNECT SERVICE r------------------- ------- SOLARPHOTOVOLTAIC ARRAYS) - - J PHOTOVOLTAIC BACK—FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V JB-01 81110 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL THE INFORMATION HEREIN JOB NUMBERFERRIES, JUDY FERRIES RESIDENCE Y 9 ;05olarCit . CONTAINED SHALL NOT E USED FOR THE Lalita Na a am �. ! BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �. s NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type c 31 OXBOW CIR 17.34 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: NORTH ANDOVER, MA 01845 THE SALE AND USE OF THE RESPECTIVE (68) CANADIAN SOLAR # CS6P-255PX 24 st Martin Drive, Building 2 Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV DATE Marlborough,MA 01752 INVMTER: L (650)638-1028 F. (650)638-1029 PERMISSION Of SOLARgTY INC. SOLAREDGE SE760OA—USOOOSNR2 9786888589 SITE PLAN PLACARD PV 7 10/3/2014 (sea)—soL—CiTY(765-2489) www.solarcity.com Label Location: Label Location: Label Location: NIARNING;PHOTOVOLTAIC PONDER SOURCE WARNING P' WARNING ' Per Code: Per Code: Per Code: NEC • ELECTRIC SHOCK HAZARDNEC •. ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS THE DC CONDUCTORS OF THIS NEC 690.35(F) Label • •n: TO BE USED WHEN PHOTOVOLTAIC DC LOADNTDHESOPEN POSNTIONIZED MAYBEOENDINVERTERIS ERGIZED DISCONNECTPer Code: UNGROUNDED NEC .•0 LabelLabel Location: WARNING MAXIMUM POWER- A D INVERTER OUTPUT 690.64.13.7- Code: POINT CURRENT(Imp)_ MAXIMUM POWER- NEC 690.53 CONNECTION POINT VOLTAGE(Vmp)-�� DO NOT RELOCATE MAXIMUM SYSTEM THIS OVERCURRENT VOLTAGE(Voc)_V DEVICE SHORT-CIRCUIT A CURRENT(Isc} Label • • PHOTOVOLTAIC POINT OF '• Label Location: INTERCONNECTIONPer Code: _ WARNING: ELECTRIC SHOCK NEC 690.17.4; 690.54 Per WARNING HAZARD. DO NOT TOUCH Code: TERMINALS.TERMINALS ON ELECTRICAL SHOCK HAZARD 690.17(4) MAY BE ENERGIZED IN THE OPEN TERMINALS ON BOTH LINE AND POSITION. FOR SERVICE LOAD SIDES MAY BE ENERGIZED DE-ENERGIZE BOTH SOURCE IN THE OPEN POSITION AND MAIN BREAKER. DC VOLTAGE IS PV POWER SOURCE ALWAYS PRESENT WHEN MAXIMUM AC A SOLAR MODULES ARE OPERATING CURRENT EXPOSED TO SUNLIGHT MAXIMUM AC OPERATING VOLTAGE V Label • • WARNING -_ • ' Per ELECTRIC SHOCK HAZARD 690.5(C) CAUTIODCode: IF A GROUND FAULT IS INDICATEDPHOTOVOLTAIC SYSTEM NORMALLY GROUNDED CIRCUIT IS BACKFED 690.64.13.4 CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED Label • • el Location: PHOTOVOLTAIC AC • '•' Du C owJERIsOoN cE •'Code: Disconnect AC •••- SECOND SOURCE IS •• •, Conduit • DISCONNECT PHOTOVOLTAIC SYSTEM Combiner :• . Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit Label . . InverterDisconnect -. -. . MAXIMUM AC A • ) (LC): Load Center CURRENTPer Code: Meter(M): Utility MAXIMUM AC V 690.54 • of • • OPERATING VOLTAGE — nnn wenn■■n■ n■ nnonn ■uv�■ • . SIC Label — mnirnmiunw■nmem■nrnunnn . . � •. I � unmu:• a unncm:nm■■■■unwnuinuu s SolarCity SleekMountTM - Comp SolarCity SleekMountTM - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed - Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM"modules C, N aesthetics while minimizing roof disruption and ,: 0 Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and •Interlock and grounding devices in system UL listed to UL 2703 Fastener Size Per NDS Section 1.1.3.2 mounting clamps, combined with the addition of array trim and a lower profile all contribute • Interlock and Ground Zep ETL listed to UL 1703 Seal pilot hole with roofing sealant to a more visually appealing system.SleekMount as"Grounding and Bonding System" \ O Insert Comp Mount flashing under upper utilizes Zep Compatible TM modules with •Ground Zep UL and ETL listed to UL 467 as layer of shingle strengthened frames that attach directly to grounding device Zep Solar standoffs, effectively eliminating the ® Place Comp Mount centered need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition .Anodized components for corrosion resistance ( Install lag pursuant to NDS Section 11.1.3 shingles are not required to be cut for this with sealing washer. system,allowing for minimal roof disturbance. •Applicable for vent spanning functions © Secure Leveling Foot to the Comp Mount using machine Screw R _ 0 Place module ® Components © ® 5/16"Machine Screw ® Leveling Foot © Lag Screw tG t�D Comp Mount © Q Comp Mount Flashing D obi 0 'b"d OT11=1) ' ��SolarCity �� ����SolarCity® January 2013 �o�pr: U� LISTED �t ry m January 2013 e�EdIli,gees,g� ®D0� CS6P-235/240/245/250/255PX NeaK`�to,,g� _r CanadianSolar Electrical Data Black-framed STC CS6P-235P CS6P-240P CS6P-245P CS6P-250PXCS6P-255PX Temperature Characteristics Nominal Maximum Power(Pmax) 235W 240W 245W 250W 255W _ _ Optimum Operating Voltage(Vmp) 29.8V 29.9V 30.OV 30.1V 30.2V Pmax -0.43%/•C Optimum Operating Current(Imp) 7.90A 8.03A 8.17A 8.30A 8.43A Temperature Coefficient Voc -0.34%/°C Open Circuit Voltage(Voc) 36.9V 37.OV 37.1V 37.2V 37.4V Isc 0.065%/•C Black-framed Short Circuit Current(Isc) 8.46A 8.59A 8.74A 8.87A 9.00A Normal Operating Cell Temperature 4512"C • Module Efficiency 14.61% 14.92% 15.23% 1 15.54% 15.85% Operating Temperature -40•C-+85•C Performance at Low Irradiance Maximum System voltage 1000v IEC /600V UL Industry leading performance at low irradiation Maximum Series Fuse Rating 15A environment,+95.5%module efficiency from an Application Classification ClassA irradiance of 1000w/m'to 200w/m' Power Tolerance 0-+5W (A 11.5,25•C) Next Generation Solar Module Under Standard Test Conditions(STC)ofirradiance of 1000W/m',spectrum AM 1.5 and cell temperature of 25'C NewEdge,the next generation module designed for multiple Engineering Drawings types of mounting systems,offers customers the added NOCT CS6P-235PXCS6P-240PXCS6P-245P CS6P-250PX CS6P-255PX Nominal Maximum Power(Pmax) 170W 174W 178W 181W 185W value of minimal system costs,aesthetic seamless Optimum Operating Voltage(Vmp) 27.2V 27.3V 27.4V 27.5V 27.5V j appearance,auto groundingand theft resistance. Optimum Operating Current(Imp) 6.27A 6.38A 6.49A 6.60A 6.71A Open Circuit Voltage(Voc) 33.9V 34.OV 34.1V 34.2V 34.4V The black-framed CS6P-PX is a robust 60 cell solar module Short Circuit Current(Isc) 6.86A 6.96A 7.08A 7.19A 7.29A incorporating the groundbreaking Zep compatible frame. under Normal operating cell Temperature,Irradiance of Boo W/m2,spectrum AM 1.5,ambient emperature 20V, The specially designed frame allows for rail-free fast wind speed 1 m/s installation with the industry's most reliable grounding Mechanical Data system.The module uses high efficiency poly-crystalline Cell Type Poly-crystalline 156 x 156mm,2 or 3 Busbars Key Features silicon cells laminated with a white back sheet and framed Cell Arrangement 60(6 x 10) with black anodized aluminum.The black-framed CS6P-PX Dimensions 1638 x 982 x 40mm(64.5 x 38.7 x 1.57in) • Quick and easy to install - dramatically is the perfect choice for customers who are looking for a high Weight 20.5kg(45.2 lbs) reduces installation time quality aesthetic module with lowest system cost. Front cover 3.2mm Tempered glass • Lower system costs - can cut rooftop Frame Material Anodized aluminium alloy installation costs in half Best Quality Box IP65,3 diodes 235 quality control points in module production Cable 4mm'(IEC)/12AWG(UL),1000mm Connectors MC4 or MC4 Comparable • Aesthetic seamless appearance - low profile • EL screening to eliminate product defects Standard Packaging(Modules per Pallet) zapcs with auto leveling and alignment • Current binning to improve system performance Module Pieces per container(40 ft.Container) 672pcs(40'HQ) • Accredited Salt mist resistant • Built-in hyper-bonded grounding system - if it's I-V Curves (CS6P-255PX) mounted,it's grounded Best Warranty Insurance °a „ • Theft resistant hardware • 25 years worldwide coverage • 100%warranty term coverage ° k ° ( sectienA-A j • Ultra-low parts count - 3 parts for the mounting • Providing third party bankruptcy rights and grounding system • Non-cancellable Immediate covera • coverage ' ,1 Industry first comprehensive warranty insurance by , AM Best rated leading insurance companies in the • Insured by 3 world top insurance companies °TZ-__ world - Comprehensive CertificatesI • Industry leading plus only power tolerance:0 5W 1 , _,U • IEC 61215,IEC 61730, 1EC61701 ED2,UL1703, 740 a Ifs • Backward compatibility with all standard rooftop and CEC Listed,CE and MCS ' ground mounting systems • IS09001:2008:Quality Management System I.SO/T.S 16949:2009:The automotive quality 'Specifications included in this datasheet are subject to change without prior notice. • Backed By Our New 10125 Linear Power Warranty management system Plus our added 25 year insurance coverage • IS014001:2004:Standards for Environmental About Canadian Solar management system Canadian Solar Inc. is one of the world's largest solar Canadian Solar was founded in Canada in 2001 and was t00% • companies. As a leading vertical) Inte rated successful) listed on NASDAQ Exchange (symbol: CSIQ in a0% Added y QC080000 HSPM:The Certification for P 9 Y- 9 Y g ( Y ) afue From Hazardous Substances Regulations manufacturer of ingots,wafers,cells,solar modules and November 2006. Canadian Solar has module manufacturing eo% ; warranty 9 solar systems, Canadian Solar delivers solar power capacity of 2.05113W and cell manufacturing capacity of 1.3GW. • OHSAS 18001:2007 International standards for products of uncompromising quality to worldwide 80% occupational health and safety customers. Canadian Solar's world class team of 0% s to is zo zs • REACH Compliance professionals works closely with our customers to provide them with solutions for all their solar needs. °° Ontario • 10 year product warranty on materials and workmanship z X $p• .vc�iac 4`;,�Ea*I •25 year linear power output warranty O Ca'C` �� v �- Fax:+1 5198372550 www.canadiansolar.com EN-Rev 10.17 Copyright 0 2012 Canadian Solar Inc. • solar " • • solar ' 9 9 IT SolarEdge Power Optimizer Module Add-On for North America P300 / P350 / P400 SolarEdge Power Optimizer Module Add-On For North America (for 6-ce P350 9400 60-cell PV (for 72-cell PV (for 96-cell PV modules) modules) modules) P300 / P350 / P400 • INPUT Rated Input DC Powerl'� 300 350 400 W Absolute Maximum In ut Volta a Voc at lowest tem erature 48 60 80 Vdc ............................................................................................................................................................................ M PPT Operating Range 8-48 8-60 8-80 Vdc ............................................................................................................................................................................ • Maximum Short Circuit Current(Isc) 30 Adc Mazimum DC Input Current 12.5 Adc .............................................................................................................................................................................. Maximum Efficiency 99.5 % .............................................................................. ................................................................................................ Weighted Efficiency98.8 % ............................................................................................................................................................................... Overvoltage Category III OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) _ Maximum Output Current 15 Adc Maximum Output Voltage 60 Vdc • OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE f!_�ril' EMC FCC Part15 Class B,IEC61000-6-2,IEC63000-6-3 Safety IEC62109-1(class II safety),UL1741 e .............................................................. ................................................................................................ ................ RoHS Yes I INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions(WxLx H) 141x212x40.5/S.SSx834x1.59 mm/in Weight(including cables) 950/2.1 gr/lb ................................................................................ .............................................. Input Conneaor...............................................................................I....MC4/Amphenol/Tyco........................................ Output Wire Type/Connector Double Insulated;Amphenol Output Wire Length.............................................................:95./.3:........1............... 1.2/3.9 m/ft ...................................................... I .Operating Temperature Range......................................................................40-+85/40-+185...............................N/.*F... Protectlon Rating IP65/NEMA4 ................................................................................................................................................................. ............. Relative Humidity 0-100 % ���RateE Srt Dower of tie nioaule.MOEuIe of uD co�5%power takrance albweE. PV SYSTEM DESIGN USING A SOLAREDGE SINGLE PHASE THREE PHASE THREE PHASE INVERTER 208V 480V PV power optimization at the module-level ................... inimum String Length(Power Optimizers) a l0 16 ...... ......................................................... — Up to 25%more energy Maximum String Length(Power Optimizers) 25 25 SO Maximum Power per String 5250 6000 12750 W — Superior efficiency(99.5%) ........ ........ ...... —.....I. .I................. ... .... .......... ... ........................................................... f Different ths or Orientations Yes Leng — Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading Parallel Strings o — Flexible system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module-level monitoring Module-level voltage shutdown for installer and firefighter safety USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us