Loading...
HomeMy WebLinkAboutBuilding Permit #362-13 - 32 CIDERPRESS WAY 11/1/2012 TOWN OF NORTH ANDOVER APPLICATION FOR PLAN EXAMINATION Permit NO: I Date Received Date Issued: I �v IMPORTANT: Applicant must complete all items on this page LOCATION 3 2�' �oV �tVlNLS rint / PROPERTY OWNER 7l— Print 100 Year Old Structure yes MAP NO: I 1 qL PARCEL:-3) ZONING DISTRICT: Historic District yes Machine Shop Village yes o TYPE OF IMPROVEMENT PROPOSED USE Residential Non- Residential V,New Building ❑ One family ❑Addition Lf tTwo or more family ❑ Industrial ❑Alteration No. of units:ONE nFTN't Wy 11'S ❑ Commercial ❑ Repair, replacement ❑Assessory Bldg ❑ Others: ❑ Demolition 0 Other ❑ Septic ❑Well ❑ Floodplain ❑Wetlands ❑ Watershed District Water/Sewer DESCRIPTION OF WORK TO BE PERFORMED: s �Z T�N�1ot� - Rfl�� 5jAk)g1[ Rq FIvA vV l7- I tifi tion Please Type or Print Clearly) OWNER: Name:. J . Phone:`T7�'` 0?Address: S CONTRACTOR Name:!_dzg �r)l L)z, -L Phone: g7L997?A-? Address: t) )V/r S Supervisor's Construction License: ��' Exp. Date: Y - Home Improvement License: tiJ/A Exp. Date: ARCHITECT/ENGINEER( (IUe,, r 4 P� Phone: 77) Address:S'KO m y R e .h , A D t��9 Reg. No. FEE SCHEDULE.BOLDING PERMIT.$12.00 PER$1000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PER S.F. Total Project Cost: $ LY 7, �Z �'•6V FEE: $ 314 l-S o Check No.: 33,03 Receipt No.: ,�q 01 NOTE: Persons contracting with unregistered con ractors do not have access to the guayyfu Signature of Agent/Owner Signature of contractor Plans Submitted ans Waived ❑ Certified Plot Plan ❑ amped Plans ❑ Location JZ. 0 No. lOZ Date ( 1 Z ® • TOWN OF NORTH ANDOVER ¢ m s Certificate of Occupancy Building/Frame Permit Fee Foundation Permit Fee $ Other Permit Fee $ TOTAL $?1�I •`�� Check# 25901 Building Inspector Plans Submitted( Plans Waived ❑ Certified Plot Plan ❑ Stamped Plans ❑ TYPE OF SEWERAGE DISPO,SSArL Public Sewer Tanning/Massage/Body Art ❑ Swimming Pools ❑ Well ❑ Tobacco Sales ❑ Food Packaging/Sales ❑ Private(septic tank,etc. ❑ Permanent Dumpster on Site ❑ THE FOLLOWING SECTIONS FOR OFFICE USE ONLY INTERDEPARTMENTAL SIGN OFF - U FORM DATE REJECTED DATE APPROVED PLANNING & DEVELOPMENT ❑ ❑ COMMENTS C X CONSERVATION Ewed on N Signature COMMENTS HEA Re ' ed on Signature COMMENTS Zoning Board of Appeals: Variance, Petition No: Zoning Decision/receipt submitted yes Planning Board Decision: Comments Conservation Decision: Comments Water & Sewer Connection/Signature Date Driveway Permit DPW Town Engineer: Signature: Located 384 Osgood Street FFire E DEPARTMENT - Temp Dumpster on site yes no ed at 124.Main Street Department signatureldate COMMENTS Dimension Number of Stories: Z Total square feet of floor area, based on Exterior dimensions. Total land area, sq. ft.: 3b Z ELECTRICAL: Movement of Meter location, mast or service drop requires approval of Electrical Inspector n Yes No DANGER ZONE LITERATURE: Yes No MGL Chapter 166 Section 21A—F and G min.$100-$1000 fine NOTES and DATA— For department use *ZS 7 6ZS. 0 ® Notified for pickup - Date Doc.Building Permit Revised 2010 Building Department The following is a list of the required forms to be filled out for the appropriate permit to be obtained. Roofing, Siding, Interior Rehabilitation Permits ❑ Building Permit Application ❑ Workers Comp Affidavit ❑ Photo Copy Of H.I.C. And/Or C.S.L. Licenses o Copy of Contract ❑ Floor Plan Or Proposed Interior Work ❑ Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit Addition Or Decks ❑ Building Permit Application ❑ Certified Surveyed Plot Plan ❑ Workers Comp Affidavit ❑ Photo Copy of H.I.C. And C.S.L. Licenses ❑ Copy Of Contract ❑ Floor/Crossection/Elevation Plan Of Proposed Work With Sprinkler Plan And Hydraulic Calculations (If Applicable) ❑ Mass check Energy Compliance Report (If Applicable) ❑ Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit New Construction (Single and Two Family) ❑ Building Permit Application ❑ Certified Proposed Plot Plan ❑ Photo of H.I.C. And C.S.L. Licenses ❑ Workers Comp Affidavit ❑ Two Sets of Building Plans (One To Be Returned) to Include Sprinkler Plan And Hydraulic Calculations (If Applicable) ❑ Copy of Contract ❑ Mass check Energy Compliance Report ❑ Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit In all cases if a variance or special permit was required the Town Clerks office must stamp the decision from the Board of Appeals that the appeal period is over. The applicant must then get this recorded at the Registry of Deeds. One copy and proof of recording must be submitted with the building application Doc: Doc.Building Permit Revised 2012 0.4 40RTh 4'1! Ox..re"1y y �aSACHU5f1 CERTIFICATE OF USE & OCCUPANCY 'SOWN OF NORTH ANDOVER Building Permit Number 362-13 on 11/1/2012 Date: December 20, 2012 THIS CERTIFIES THAT THE BUILDING LOCATED ON 32 Ciderpress Way MAY BE OCCUPIED AS a single family home IN ACCORDANCE WITH THE PROVISIONS OF THE MASSACHUSETTS STATE BUILDING CODE AND SUCH OTHER REGULATIONS AS MAY APPLY. Certificate Issued to: Tara Leigh Development LLC 115 Carter Field Road North Andover,MA 01845 Building Inspector Fee: Pre Paid Receipt: 25901 Check : 3353 LAWRENCE H.OGDEN,PE. 198 EAST MAIN STREET GEORGETOWN,M-1.01833 978-352-8318 fax 978 352-2858 cell 978-502-5921 November 12,2012 Mr. Thomas Zahoruiko Meeting House Commons,LLC. 115 Carter Field Road North Andover,Ma. 01845 Re:Meeting House Commons,LLC.,North Andover,Ma. 01845 Dear Mr.Zahoruiko As you requested I visited the site November 12,2012 to review the installation of the Engineered Materials consisting of LVLs and Steel Beams utilized in the framing of the above project for Unit 32 Ciderpress Rd. These Engineered Materials are shown on plans prepared by O'Sullivan Architects Dated 12-17-09 with the framing plans certified by me 12-17-09,and revised framing sketches SK-1 to SK-4 dated 3/14/10 And UNIT A revised rear shear wall dated 5/12/10. Based on the above site visit and on what I could visibly see provided the below Iisted exceptions are corrected I can certify that to the best of my knowledge the LVLs and Steel Beam members utilized in the framing as shown on the drawings are installed properly and meet the loading conditions of the 7h. Edition of the Massachusetts State Building Code, 1.0 Insure all LVLs are connected together per the drawings see sheet A0.11. 2.0 Insure interior and exterior Shear walls are nailed as shown on A0.11, I did not see the bottom plate nailing,the remaining nailing was not visable. This certification is limited to the installation of LVL and Steel beams. All other framing requirements of the drawings and code,including but not limited to materials, nailing schedules, blocking,connections,other details and manufactures installation requirements remain the responsibility of the framer and the licensed construction supervisor responsible for the project. Should you have any questions please do not hesitate to call. � -V1%OF"'tr,�cy Yours truly, CA l►r wrence H. Ogden?.E. Structural 27765 o c, �� Ffss n�E ANG LAWRENCE H.OGDEN,PE. 198 EAST ALAN STREET GEORGETOW34 MA 01833 978-352-8318 fax 978—352-2858 cell 978-502-5921 November 12,2012 Mr.Thomas Zahoruiko Meeting House Commons,LLC. 115 Carter Field Road North Andover,Ma. 01845 Re:Meeting House Commons,LLC.,North Andover,Ma. 01845 Dear Mr.Zahoruiko As you requested I visited the site November 12,2012 to review the installation of the Engineered Materials consisting of LVLs and Steel Beams utilized in the framing of the above proiect for Unit 32 Ciderpress Rd. These Engineered Materials are shown on plans prepared by O'Sullivan Architects Dated 12-17-09 with the framing plans certified by me 12-17-09,and revised framing sketches SK-1 to SK 4 dated 3/14/10 And UNIT A revised rear shear wall dated 5/12/10. Based on the above site visit and on what I could visibly see provided the below listed exceptions are corrected I can certify that to the best of my knowledge the LVLs and Steel Beam members utilized in the framing as shown on the drawings are installed properly and meet the loading conditions of the 7d`. Edition of the Massachusetts State Building Code. 1.0 Insure all LVLs are connected together per the drawings see sheet A0.11. 2.0 Insure interior and exterior Shear walls are nailed as shown on A0.11,I did not see the bottom plate nailing,the remaining nailing was not visable. This certification is limited to the installation of LVL and Steel beams. All other framing requirements of the drawings and code,including but not limited to materials, nailing schedules,blocking,connections,other details and manufactures installation requirements remain the responsibility of the framer and the licensed construction supervisor responsible for the project.. Should you have any questions please do not hesitate to call. �,��'OF"'�s,�cy Yours truly, o wwa �N X "AROUD 40 Qwrence H.Ogden P.E.Structural 27765 Sg NAl E t. f NORT#1 q O ttco j6 .1. *60 to O APPLICATION FOR CERTIFICATE OF OCCUPANCYANSPECTION Argo BUILDING PERMIT # 562-13 CH ADDRESS/LOCATION OF PROPERTY: 3 Z- 't���/ Map 1(1 G Parcel- 31 Lot Number SUBDIVISION: DATE REQUESTED FILED/READY FOR INSPECTION: � 2- A CLOSING DATE ON PROPERTY: 121*1Z FIVE (5) DAYS NOTICE PRIOR TO CLOSING DATE IS REQUIRED ALL WORK AND SIGN-OFFS MUST BE COMPLETED WITHIN THIS TIME FRAME. A REINSPECTION FEE OF TWENTY DOLLARS ($20.00) W LL BE CHARGED IF THE STRUCTURE DOES NOT MEET ALL APPLICABLE ODES. APPLICANT SIGNATURE Permit Issued to: 'L' Address: lq ("-4 Ar gdkaJ bA ,A" A ROUTING TOWN ENGINEER, SITE PLA -DRIVE-WAY REVIEW Ud All,*- CONSERVATION P ? 2q2-11 I y A,4s PLANNING I N( chi U%OR DPW-WATER METER V/ SEWER CONNECTION lir", DPW MUST INDICATE THAT THE WATER METER HAS BEEN INSTALLED PRIOR TO SUBMITTAL OF THE OCCUPANCY/INSPECTION REQUEST DPW 1� 1alig1l �- SIGNATURE File:Application for OC form revised Jan 2007/2011 RT VkOH 7.own of t E f, n over ° No. Z.h ver, Mass 01 coc«I�«ew�cw �1 Q�RATEv S U BOARD OF HEALTH Food/Kitchen PER !T LD Septic System 41A THIS CERTIFIES THAT .. .... �.. .. ®�! .... 4R. BUILDING INSPECTOR ...... � � .....,...... ...... FoullJdation has permission to erect .......................... buildin son 160% . J � eh to be occu led as ........... . .......� ►,�. .. ....�.................................................................. v,� r � .-� ,ten ' z I provided.that the person accepting this permit shall in every respect conform to the terms of the application Final on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection, Alteration and Construction of Buildings in the Town of North Andover. RLUMBING INSPEC O_ � VIOLATION of the Zoning or Building Regulations Voids this Permit. Rough j" r Final ��,Lt p� pp�� MONTHS PERMIT EXPIRES IN 6 MONTHS ELECTRICAL ASPECT UNLESS CONSTRUCTION ARTS .................... Service ................. .. �BUILDI14 .. �.. � j Z- a�—/�G INSPECTOR GAS INSPECTOR Occupancy Permit Required to Occupy Building Rough Y a p Display in Cons icuous Place on the Premises - Do Not Remove Final p No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. Burner Street No. SEE REVERSE SIDE Smoke Det-� I'� lZ_/-z� �( Enter construction cost for fee cal - North Andover Fee Cakulaflon Construction Cost $ 257,625.00 m $ - $ 3,091.50 Plumbing Fee $ 386.44 Gas Fee 100 comm. $ 100.00 Electrical Fee $ 386.44 Total fees collected $ 3,964.38 32 Ciderpress Way 362-13 on 11/1/2012 New Single Family Townhouse V4ORTH Town of tAndover 0 0% No. Z. I - b o h ver Mass �zol, ,g coc NIC Nl W'CK y1' y,�A°�i•ITEO ►PP,�,�y S U BOARD OF HEALTH Food/Kitchen PER1,T T LD Septic System THIS CERTIFIES THAT ........... .e6.a "�!`5t-.... ............... ........ BUILDING INSPECTOR :3.?....! Foundation has permission to erect .......................... buildin son .... .�/�. ® Rough to be occupied as ........... F......�Q1N� .. ..............................................................�../. Chimney provided that the person accepting this permit shall in every respect conform to the terms of the application Final on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection, Alteration and Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR Rough VIOLATION of the Zoning or Building Regulations Voids this Permit. Final PERMIT EXPIRES IN 6 MONTHS ELECTRICAL INSPECTOR UNLESS CONSTRUCTION ARTS Rough ........•.. Service ................. .. .��.. ............. Final BUILDING INSPECTOR GAS INSPECTOR Occupancy Permit Required to Occupy Building Rough Display in a Conspicuous Place on the Premises — Do Not Remove Final No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. Burner Street No. Smoke Det. SEE REVERSE SIDE tans Subml d Plans Waived Certified Plot Plan Stamped Plans TYPE OF SEWERAGE DISPOSAL ublic r Tanning/Massage/Body Art Swimming Pools Well Tobacco Sales Food Packaging/Sales Private(septic tank,etc. Permanent Dumpster on Site THE FOLLOWING SECTIONS FOR OFFICE USE ONLY INTERDEPARTMENTAL SIGN OFF- U FORM DATE REJECTED DATE APPROVED PLANNING & DEVELOPMENT -' COMMENTS � 13 '$ N �' CONSERVATION Reviewed on Signature COMMENTS-f ZDO 90-L-I I Iq i r, a<<6rACACp w10b dviQ we, I'LoJL� HEALTH Reviewed on Signature COMMENTS -litI f-4 - r tl"'ow. Zoning Board of Appeals:Variance, Petition No: Zoning Decision/receipt submitted yes Planning Board Decision: Comments Conservation Decision: 2 I Comments Water& Sewer Connection/signature Date DrivewayPermit DPW Town Engineer: Signature: Located 384 Osgood Street FIRE.DEPARTMENT- Temp Du ter onsite_ .s- no Located at 124 Main Street Fire Department signature/date COMMENTS Z Massachusetts -Department of Public Safety / Board of Building Regulations and Standards E Construction Supervisor License:C -OSU17 ZHOMAS D ZAHgkUIICO 115 CARTERFU D RD N ANDOVER Mk 018x5 Expiration Commissioner 04/05/2014 the Cnmmonweaft ofMas chrrs pop of14rial Act O.fwe oflnveSfr..jaores Workers'Co 'maw/tea k ant wbustion on�usnrancg A�davi�RmlderrJContractorsWec LidanWnnmbi. Please Name�ntionlfndividoral�_ � Pont Ip Addzeim l C r' P= of I AA Phone k Are yon an a mpdoyer9 qeg the aMwopriate b= L I am a employer with 4 ❑I mm a Type of Pro?ea(required):" - 3 �oY�(M�orpart-time).$ have hued the -COa� 6- kxm co w --� I am a sok paaptiew arpartnrr car$e sheet t 7. ship and have no employees - These� have �g *me m an �vatY s'c P•msmahav 8' ❑ [No vorlreas °omR S ❑We are. 9- ❑ addition �,� a mon and its 3_� I am a offiarshava I0.0 mal�or ba�waer doing aH work right oftx�on�mGL I1. nWwK��'�P- c.132,�I(,¢� �mvc S. or=.. no I2. msat�c,e nqu6zdj fi paim �� � j]gO {r, _Camp-hxxumce z�&] 13.0 other `S-y b=49 Hebb JM�r � $off =tb<e air' &e'er Vis"`rte,i tea*oe xConftcb-8mt�S¢bcm -e gall=G*aadT� mnpar-,—S.....diM ' �asadmdaa . �dthor am all MpkYar&at onJ'mrApygmBelow raAkepvJiI7 and ashe I umance Y)&M= Policy#or San=Lac- onDatc: Job Site Addrew Attach it copy of the woain' C P a 1Y dedurna4m�( the ccphmfim fine t°secure as regaaed Hader Section 23A ofbdGL c.i32 l 9 number and ap W SI,M.00=&or oM-year' can lead to fire hnpositiw of�P�of a of up to S130.00 a day_ the viol as meIl as civ>Z P�m Sic fMm of a STOP WORK ORDER sad a fine Iagatiams of the DIAfar nosaramcx -" that aropy ofd UIRY be ceded In the Office of 1AP hmmbl C974fy Mdow pahn ��m'mratwa,pmv' �trrie end correct, _ done#. -79-46 57!-- - - O,�ia1 use o»1,}t Da naf»in mnq to be �'�'m fMM o cw City or Tow= Ism-ku&miEy(circle or=k P iv L Board of Health L S �t 3-C /Town 6.Oti rr h 4-Eh=trjczl hmpectur S.Plumbiimg Inspector Comae Person: Pboae�: —L MAP 104C / \ LOT 30 MAP 104C LOT 29 N/F ESSEX REENBELT OUNTY NOTES. 25' NO / \ ASSOC., INC. D1 URB ONE / \ 1) THE BOUNDARY INFORMATION SHOWN HEREON WAS TAKEN FROM A PLAN ENTITLED "PLAN OF LAND, MEETINGHOUSE COMMONS AT SMOLAK FARMS, SOUTH BRADFORD STREET, NORTH ANDOVER, MAP 104C V / MASSACHUSETTS"; SCALE: 1" - 80% DATE: JULY 20, 2001 BY THIS 7 OFFICE. RECORDED AS PLAN #14828 IN THE ESSEX COUNTY LOT 28 r`3 ,�� / NORTH DISTRICT REGISTRY OF DEEDS. / 7, 2) THE INTENT OF THIS PLAN IS TO SHOW THE AS—BUILT LOCATION OF THE FOUNDATION ONLY. 3) THE FOUNDATION SHOWN HEREON IS NOT WITHIN THE 100 YEAR i FLOOD ZONE AS TAKEN FROM THE FLOOD INSURANCE RATE MAP FOR THE TOWN OF NORTH ANDOVER MASSACHUSETTS COMMUNITY PANEL NUMBER 250098 0007 C, MAP REVISED: 6/2/83. �t"q / / r`. 4) THE CONCRETE FOUNDATION SHOWN HEREON HAVE BEEN INSTALLED SUBSTANTIALLY IN ACCORDANCE WITH THE 40B SITE PLAN AS I v APPROVED BY THE TOWN OF NORTH ANDOVER PLANNING BOARD. r �— �_ �� \ 1LoQ66 /� \\�✓,/ .� \ 1 HEREBY CERTIFY THAT THE LOCATION OF THE TOWNHOUSE UNIT NUMBERS 31-35 FOUNDATION SHOWN HEREON IS THE RESULT OF A M L gtiQo\ A �� `� / FIELD SURVEY BY THIS OFFICE MADE ON SEPTEMBER 28, 2012. r� i 0.S.. OF V tl oA,ft��D10p,VJWr ` �s / ;(N 6fq £ N�' `\`.� �`. % / � ,LTiRISIOPHER FRANCHER 38118 py cZ0 LICENSED LAND SURVEYOR DATE CERTIFIED FOUNDATION PLAN MEETINGHOUSE COMMONS TOWNHOUSE UNITS 31-35 GRAPHIC SCALE CIDERPRESS LANE 6o 100 NORTH ANDOVER, MASSACHUSETTS PREPARED FOR 41. MEETINGHOUSE COMMONS, LLC (IN FEET) 121 CARTER FIELD ROAD 1 inch 50 ft NORTH ANDOVER, MASSACHUSETTS A 97B 14 SliIH Rood,Suits One Sobm,Now Hompshfm 03079 (603)693-0720 PAF NMF Design Consultontb,Inc. ENGINEERS•PLANNERS•SURVEYORS ` ~ ———————i / SCALE: 1" 50' DATE: OCTOBER 1, 2012 DRAWING AL / q N0. DESCRIPTION BY DATE DRAWN BY: I CHECKED BY: PROJECT NO. NAME AIL / REVISIONS CMF 250508 1 2505CFP.DWG