HomeMy WebLinkAboutBuilding Permit #519-2011 - 38 EMPIRE DRIVE 1/4/2011TOWN OF NORTH ANDOVER
APPLICATION FOR PLAN EXAMINATION
Permit NO: &)011
Issued: //K///
IMPORTANT:
4
Date Received
cant must complete all items on this
Print
PROPERTY OWNER —���4 P-
L -
Print .�.�- �
MAP NO:��PARCEL��ZONING DISTRICT Historic District yes
Machine Shop Village yes �d
TYPE OF IMPROVEMENT
PROPOSED USE
Residential
Non- Residential
VLNew Building
*One family
❑ Addition
11 Two or more family
11 Industrial
❑ Alteration
No. of units:
❑ Commercial
❑ Repair, replacement
❑ Assessory Bldg
❑ Others:
❑ Demolition
❑ Other
0 Septic q `Well
,..
�,Fiood'p lain ❑Wetlands
N Watefshea1' ,nct f
OWNER:
Address:'
DESCRIPTION OF WORK TO BE PERFORMED:
PloacP Tvn,- nr Print f'lenrly)
16
Z,
CONTRACTOR Name:
Address:
Supervisor's Construction License:41A2.-�,s i Exp
Home Improvement License: / q k2.- Exp
ARCHITECT/ENGINEER
w••
Date: Z --
Date:
Phone:�2' ?-3S-Z- 9-?/ 5"'
No.
FEE SCHEDULE. BULDING PERMIT: $12.00 PER $1000.00 OF THE TOTAL ESTIMATED COST BASED ON $125.00 PER S.F.
Total Project Cost: $ 3 d FEE: $
Check No.: �� Receipt No.:
NOTE: Persons contracting with unregistered contractors do not have access to the guaranty fund
Signature of�Agent/Ow ne"r Signature of contractor:
Location
No. "2o/' Date y /�
NaRT►,
TOWN OF NORTH ANDOVER
OL
9
Certificate of Occupancy
$ /bo
JCMUs <�'
Building/Frame Permit Fee
$ </ 7 Gv
Foundation Permit Fee
$
Other Permit Fee
$
TOTAL
$ 4-11 �6
Check #
2 3 6 3 kf6ibng Inspector
Plans Submitted 14 Plans Waived ❑ Certified Plot Plan pal Stamped Plans 9
TYPE OF SEWERAGE DIS702%anning/Massage/Body
Public Sewer
Art ❑
Swimming PoolsWell
bacco Sales ❑
Food Packaging/Sales ❑
Private (septic tank, etc. ❑
permanent Dumpster on Site ❑
THE FOLLOWING SECTIONS FOR OFFICE USE ONLY
INTERDEPARTMENTAL SIGN OFF - U FORM
DATE REJECTED DATE APPROVED
PLANNING & DEVELOPMENT ❑ ❑
COMMEN
CONSERVATION Reviewed on—I L `(J / I
COMMENTS 0-6 Zy
HEALTH Reviewed on Siqnature
COMMENTS
Zoning Board of Appeals: Variance, Petition No: Zoning Decision/receipt submitted yes
Planning Board Decision: Comments
N61.Conservation Decision:
w. ._ter & Sewer Connectio
DPW Town Engineer:
FIRE DEPARTMENT - Temp
Located at 124 Main Street
Fire Department signature/date
COMMENTS
Comm
Located 384
Dimension
Number of Stories: Total square feet of floor area, based on Exterior dimensions.
Total land area, sq. ft.:
ELECTRICAL: Movement of Meter location, mast or service drop requires approval of
Electrical Inspector Yes No
DANGER ZONE LITERATURE: Yes No
MGL Chapter 166 Section 21A —F and G min.$10041000 fine
NOTES and DATA — For department use
U Notified for pickup - Date
Doc:.Building Permit Revised 2008
Building Department
The following is a list of the required forms to be filled out for the appropriate permit to be obtained.
Roofing, Siding, Interior Rehabilitation Permits
❑ Building Permit Application
❑ Workers Comp Affidavit
❑ Photo Copy Of H.I.C. And/Or C.S.L. Licenses
❑ Copy of Contract
❑ Floor Plan Or Proposed Interior Work
❑ Engineering Affidavits for Engineered products
NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit
- Addition Or Decks
❑ Building Permit Application
❑ Certified Surveyed Plot Plan
❑ Workers Comp Affidavit
❑ Photo Copy of H.I.C. And C.S.L. Licenses
❑ Copy Of Contract
❑ Floor/Crossection/Elevation Plan Of Proposed Work With Sprinkler Plan And
Hydraulic Calculations (If Applicable)
❑ Mass check Energy Compliance Report (If Applicable)
❑ Engineering Affidavits for Engineered products
NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit
New Construction (Single and Two Family)
❑ Building Permit Application
❑ Certified Proposed Plot Plan
❑ Photo of H.I.C. And C.S.L. Licenses
❑ Workers Comp Affidavit
❑ Two Sets of Building Plans (One To Be Returned) to Include Sprinkler Plan And
Hydraulic Calculations (If Applicable)
o Copy of Contract
❑ Mass check Energy Compliance Report
❑ Engineering Affidavits for Engineered products
NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit
In all cases if a variance or special permit was required the Town Clerks office must stamp the decision from the Board of Appeals
that the appeal period is over. The applicant must then get this recorded at the Registry of Deeds. One copy and proof of recording
must be submitted with the building application
Doe: Doc.Building Permit Revised 2008mi
z
0
w
w
P-4
W
co
o
w°
a
cn
U
w
ra
w°
x
a
U
w
w
a
-Q
w
O
a
i
CO cn
w
a
O
w�'
w
W
m m
oco
cn
Q
cn
z
0
w
w
P-4
W
co
c o r
co
L
Cl
as c
s
Z
3^
CL
c
y
C
i
W vI
C2 `
QCl
co
CO2
co
C H
m m
CD
CL
CD C13
_O C
co
C.3 C3
�
co
Q
L-
o
d�
a
�a
C. C
O R
c
vCc
J .0
CO C
049
CO2
Z Ca
co
Q
Q)
CL
vs
CIO
C
C
c
a
D
E
•r
y
O
CD
�.
m
(�
.10 Qa
caE
oCD
y �
V:
u cm
:CD
CL--
co
L L
H
., 3
Qf
m
;5.5CD
y
_
�Ca
s
V'
N O
O
E m
CM
O ;
N
'mom
m
yZ
C.3
O.�
O
•
LO
0
cm
C
Q
d
e m c
•O
=
o
: o 3
N
0
dS O
CD
CD
W
o
� •+ � t
�.
•N
.., c •-
�O O
O
oc
E
t C
�"mca
o
v
m`
omc
g
h
a
o�o�
.O h �O
O
_
�=.aZm5
W
c
z
0
w
w
P-4
W
co
CD
co
L
Cl
s
Z
3^
CL
O
�
y
C
i
W vI
QCl
co
CO2
co
.g
m m
CD
CL
CD C13
co
o
�
co
Q
L-
o
env
a
a
�a
C2
c
vCc
J .0
.CL
049
CO2
Z Ca
co
Q
Q)
CL
vs
CIO
C
C
c
CLCO2
D
Required on the warm -in -winter side of all non -vented framed
ceilings, walls, and floors.
MATERIALS IDENTIFICATION:
Materials and equipment must be identified so that compliance can
be determined. Manufacturer manuals for all installed heating
and cooling equipment and service water heating equipment must be
provided. Insulation R -values, glazing U -values, and heating and
cooling equipment efficiency must be clearly marked on the building
plans or specifications.
DUCT INSULATION:
Ducts shall be insulated per Table J4.4.7.1.
DUCT CONSTRUCTION:
All accessible joints, seams, and connections of supply and return
ductwork located outside conditioned space, including stud bays or
joist cavities/spaces used to transport air, shall be sealed
using mastic and fibrous backing tape installed according to the
manufacturer's installation instructions. Mesh tape may be
omitted where gaps are less than 1/8 inch. Duct tape is not
permitted. The HVAC system must provide a means for balancing
air and water systems.
TEMPERATURE CONTROLS:
Thermostats are required for each separate HVAC system. A manual
or automatic means to partially restrict or shut off the heating
and/or cooling input to each zone or floor shall be provided.
HVAC EQUIPMENT SIZING:
Rated output capacity of the heating/cooling system is
not greater than 125% of the design load as specified
in Sections 780CMR 1310 and J4.4.
SWIMMING POOLS:
All heated swimming pools must have an on/off heater switch and
require a cover unless over 20% of the heating energy is from
non-depletable sources. Pool pumps require a time clock.
HVAC PIPING INSULATION:
HVAC piping conveying fluids above 120 F or chilled fluids
below 55 F must be insulated to the following levels (in.):
HEATING SYSTEMS:
Low pressure/temp.
Low temperature
Steam condensate
COOLING SYSTEMS:
Chilled water or
refrigerant
CIRCULATING HOT WATER SYSTEMS:
Insulate circulating hot water pipes to the following levels (in.):
PIPE SIZES (in.)
PIPE
SIZES
(in.)
TEMP (F)
2" RUNOUTS
0-1"
1.25-2"
2.5-4"
201-250
1.0
1.5
1.5
2.0
120-200
0.5
1.0
1.0
1.5
any
1.0
1.0
1.5
2.0
40-55
0.5
0.5
0.75
1.0
below 40
1.0
1.0
1.5
1.5
CIRCULATING HOT WATER SYSTEMS:
Insulate circulating hot water pipes to the following levels (in.):
PIPE SIZES (in.)
NON -CIRCULATING I CIRCULATING MAINS & RUNOUTS
j HEATED WATER TEMP (F): RUNOUTS
0-1" I 0-1.25"
1.5-2.0"
2.0+"
170-180
0.5
I 1.0
1.5
2.0
j 140-160
0.5
I 0.5
1.0
1.5
100-130
I
0.5
I 0.5
0.5
1.0
----NOTES TO FIELD
(Building Department
Use Only)-------------------------
MAScheck COMPLIANCE REPORT
Massachusetts Energy Code
MAScheck Software Version 2.01 Release 2
CITY: North Andover
STATE: Massachusetts
HDD: 6322
CONSTRUCTION TYPE: 1 or 2 Family, Detached
HEATING SYSTEM TYPE: Other (Non -Electric Resistance)
DATE: 12-28-2010
DATE OF PLANS: 6/9/10
TITLE: The Kingston
PROJECT INFORMATION:
Orchard Village, Lot 8 #38 Empire Drive
COMPANY INFORMATION:
Orchard Village, LLC
COMPLIANCE: PASSES
Required UA = 556
Your Home = 332
Permit #
Checked by/Date
Area or
Cavity
Cont.
Glazing/Door
Perimeter
R -Value
R -Value
U -Value
UA
-------------------------------------------------------------------------------
CEILINGS 1425
38.0
0.0
43
WALLS: Wood Frame, 16" O.C. 2505
20.0
0.0
148
BSMT: Conc. 8.0' ht/7.0' bg/0.0' insul 0
0.0
0.0
0
GLAZING_: Windows or Doors 307
0.350
107
DOORS 70
0.000
0
FLOORS: Over Unconditioned Space 1025
30.0
0.0
34
HVAC EQUIPMENT: Furnace, 96.0 AFUE
HVAC EQUIPMENT: Air Conditioner, 13.0 SEER
-------------------------------------------------------------------------------
COMPLIANCE STATEMENT: The proposed building
design described
here is
consistent with the building plans, specifications,
and
other
calculations
submitted with the permit application. The
proposed
building
has been
designed to meet the requirements of the Massachusetts
Energy
Code.
The heating load for this building, and the cooling load if appropriate,
has been determined using the applicable Standard Design Conditions found
in the Code. The HVAC equipment selected to heat or cool the building
shall be no greater than 125% of the design load as specified in
Sections 780CMR 1310 and J4.4.
Builder/Designer Date
Massachusetts Energy Code
MAScheck Software Version 2.01 Release 2
The Kingston
DATE: 12-28-2010
Bldg.
Dept.
Use
CEILINGS:
1. R-38
Comments/Location
WALLS:
1. Wood Frame, 16" O.C., R-20
Comments/Location
BASEMENT WALLS:
1. Conc. 8.0' ht/7.0' bg/0.0' insul, R-0 (uninsulated)
Comments/Location
WINDOWS AND GLASS DOORS:
1. U -value: 0.35
For windows without labeled U -values, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments/Location
DOORS:
1. U -value: 0
Comments/Location
FLOORS:
1. Over Unconditioned Space, R-30
Comments/Location
HVAC EQUIPMENT:
1. Furnace, 96.0 AFUE or higher
Make and Model Number
2. Air Conditioner, 13.0 SEER or higher
Make and Model Number
AIR LEAKAGE:
Joints, penetrations, and all other such openings in the building
envelope that are sources of air leakage must be sealed. When
installed in the building envelope, recessed lighting fixtures
shall meet one of the following requirements:
1. Type IC rated, manufactured with no penetrations between the
inside of the recessed fixture and ceiling cavity and sealed or
gasketed to prevent air leakage into the unconditioned space.
2. Type IC rated, in accordance with Standard ASTM E 283, with no
more than 2.0 cfm (0.944 L/s) air movement from the the
conditioned space to the ceiling cavity. The lighting fixture
shall have been tested at 75 PA or 1.57 lbs/ft2 pressure
difference and shall be labeled.
VAPOR RETARDER:
EMPIRE DR.
FOUNDATION L OCA TION THIS CMN' SHALL NOTBE USED BY THECLIENTFORANY
PURPOSE OTHER THAN THAT OUTLINED ABOVE EXCEPT WITH
THE I INC
CLIENT- ORCHARD VILLAGE, LLC FURTHERMORE
ISDRANINGOF IST ECOPENQSERGPRO
FURTHF_RIIfORE THIS DRAWING IS THE COPYRIGHTED PROPERTY
OFCHRISTIANSENd SERGI INC ANDANY VML17HaMED USE IS
THIS CERTIRCATION IS MADEAND LIMITED TO THEABOVE CLIENT PROHIB/TED.ChIVS/14NSEN A SERB! TAKES NO RESPONSMILITY
LOCATION. NORTHANDOVER,MA. ; FH,Nl O ms's DR1 N01Ri0NY
DATE.' 12/23/10 SCALE:1 "=30' BASED ON SCALED DA TAGNLYTHE PRIMARYSTRUCTURE
SHOWN IS NOT LOCATED INA FLOOD HA2ARD200VEAS SHOWN
ON FEMA FLOOD /NSURANCERA TE MAP. COMWAITYNO.:250098
0008C DATE-*Wl9932ONEX
PROFESSIONAL ENGINEERS & LAND SURVEYORS
CHRISTIANSEN & SERGI INC.
160 SUMMER STREET, HAVERHILL, MASSACHUSETTS 01830
WWW. CSI-ENGR. COM TEL. 978-373-0310 FAX 978-372-3960
D WG. NO.: 06029.001.047