Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Building Permit #444-15 - 44 EQUESTRIAN DRIVE 11/6/2014
O� r►ORTH et��a° *6�ti0 BUILDING PERMIT r 3a ,.„.r. . O� - TOWN OF NORTH ANDOVER i APPLICATION FOR PLAN EXAMINATION Permit NO: Date Received <Argo �=�= •.�' �9SS�cMUS�� Date Issued: �P IMPORTANT: Applicant must complete all items on this page LOCATION 44 Equestrian Dr Print PROPERTY OWNER Nancy Sarro ') Print MAP NO PARCEL: ZONING DISTRICT: Historic District yes no t z, Machine Shop Village es no K�r TYPE OF IMPROVEMENT PROPOSED USE Residential Non- Residential ❑ New Building E30ne family ❑Addition QTwo or more family ❑ Industrial ❑ Alteration No. of units: ❑ Commercial ❑ Repair, replacement ❑Assessory Bldg ❑ Others: ❑ Demolition DOther Solar/PV ❑ Septic ❑Well ❑ Floodplain ' ❑Wetlands ❑ Watershed District i ❑Water/Sewer Install 42 solar electric panels @10.71M DC to roof of existing home, to be interconnected with the homes' electrical system Identification Please Type or Print Clearly) OWNER: Name: Nancy Sarro Phone: (617)435-3524 Address: 44 Equestrian Dr CONTRACTOR Name: Phone: 978-215-2383 SolarCity Corp Address: 800 Research Dr.Wilmington Ma.01887 Supervisor's Construction License: Exp. Date: 107663 8/29/2017 Home Improvement License: Exp. Date: 168572 3/8/2015 ARCHITECT/ENGINEER Phone: Address: Reg. No. FEE SCHEDULE:BULD/NG PERMIT.$12.00 PER$1000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PER S.F. Total Project Cost: $27,000 FEE: $ Check No.: :1-1�9)a f?tP Receipt No.: X45 2 3 NOTE: Persons contracting with unregistered contractors do not have access to the guaranty fund ignature of Agent'Owner Signature of contractor ( 8V— 1 __ - e. Ll (141-1 Location S No. " 1iD Date a . - TOWN OF NORTH ANDOVER Certificate of Occupancy $ Building/Frame Permit Fee $ ,3 Foundation Permit Fee $ Other Permit Fee $ TOTAL $ 611�Check 0 I� J �. u 20 J Building Inspector Plans Submitted.❑.- Plans Waived El Certified Plot Plan'.❑ --,Stamped Plans ❑ f TYPE'OF SEWERAGE DISPOSAL Public Sewer ❑ Tanning/Massage/Body Art ❑ Swimming Pools ❑ I Well ❑ Tobacco Sales ❑ Food Packaging/Sales ❑ Private(septic tank,etc. ❑ permanent Dumpster on Site ❑ THE FOLLOWING SECTIONS FOR OFFICE USE ONLY INTERDEPARTMENTAL SIGN OFF - U FORM PLANNING & DEVELOPMENT Reviewed On Signature_ COMMENTS CONSERVATION Reviewed on Signature i COMMENTS HEALTH Reviewed on Signature . I COMMENTS Zoning Board of Appeals: Variance, Petition No: Zoning Decision/receipt submitted yes Planning Board Decision: Comments Conservation Decision: Comments Water & Sewer Connection/Signature& Date Driveway Permit DPW Town Engineer: Signature: Located 384 Osgood Street FIRE DEPARTMENT Temp Dumpster on site yes no Located at 124 Main Street Fire Department signature/date COMMENTS _ Dimension Number of Stories: Total square feet of floor area, based on Exterior dimensions. Total land area, sq. ft.: ELECTRICAL: Movement of Meter location, mast or service drop requires approval of Electrical Inspector Yes No DANGER ZONE LITERATURE: Yes No MGL Chapter 166 Section 21A—F and G min.$100-$1000 fine NOTES and DATA — (For department use) ❑ Notified for pickup Call Email i Date Time Contact Name Doc.Building Pen-nit Revised 2014 Building Department The following is a list of the required forms to be filled out for the appropriate permit to be obtained. 11 Roofing, Siding, Interior Rehabilitation Permits ❑ Building Permit Application ❑ Workers Comp Affidavit ❑ Photo Copy Of H.I.C. And/Or C.S.L. Licenses ❑ Copy of Contract ❑ Floor Plan Or Proposed Interior Work ❑ Engineering Affidavits for Engineered products � N Bldg TE: All dumpster permits require sign off from Fire Department prior to Issuance of g Permit Addition Or Decks ❑ Building Permit Application ❑ Certified Surveyed Plot Plan ❑ Workers Comp Affidavit ❑ Photo Copy of H.I.C. And C.S.L. Licenses ❑ Copy Of Contract ❑ Floor/Cross Section/Elevation Plan Of Proposed Work With Sprinkler Plan And Hydraulic Calculations (If Applicable) ❑ Mass check Energy Compliance Report (If Applicable) ❑ Engineering Affidavits for Engineered products N TE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit New Construction (Single and Two Family) ❑ Building Permit Application ❑ Certified Proposed Plot Plan ❑ Photo of H.I.C. And C.S.L. Licenses ❑ Workers Comp Affidavit ❑ Two Sets of Building Plans (One To Be Returned) to Include Sprinkler Plan And Hydraulic Calculations (If Applicable) ❑ Copy of Contract ❑ Mass check Energy Compliance Report ❑ Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg. Permit n all cases if a variance or special permit was required the Town Clerks office must stamp the decision from the Board of Appeals at the appeal period is over. The applicant must then get this recorded at the Registry of Deeds. One copy and proof of recording ust be submitted with the building application Doc:Building Permit Revised 2014 �ORTii Town of �. Andover No. * _ h ver, Mass 2m4 ��� COC NICNt WICK LD1' S U BOARD OF HEALTH Food/Kitchen IT Septic System THIS CERTIFIES THATPER I .. . e.. ....... , �v........................... BUILDING INSPECTOR . ,. �,� .... has permission to erect .......................... buildings on .... ��.�.. ....... L Foundation . Rough to be occupied as ...�?... � .. 4�Q/!..Q' �5.............�O.l .....kw. Chimney provided that the person accepting this permifshall in every respect conform to the terms of thea application pp Final on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection,Alteration and Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR VIOLATION of the Zoning or Building Regulations Voids this Permit. Rough Final PERMIT EXPIRES IN 6 MONTHS ELECTRICAL INSPECTOR UNLESS CONSTRUC TRT - Rough Service ......% i�.................................................. Final BUILDING INSPECTOR GAS INSPECTOR Occupancy Permit Required to Occupy Building Rough Display in a Conspicuous Place on the Premises — Do Not Remove Final No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. Burner Street No. Smoke Det. The Commonwealth of Massachusetts Department of Industrial Accidents Office of Investigations _ 1 Congress Street,Suite 100 j' Boston,MA 02114-2017 • www mass gov/dia Workers'Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Annlicant Information Please Print Legibly Name(Business/Organization/Individual): SOLARCITY CORP Address:3055 CLEARVIEW WAY City/State/Zip:SAN MATEO,CA 94402 Phone#:886-765-2489 Are you an employer?Check the appropriate box: Type of project(required): 1.n I am a employer with 5000 4. ❑ I am a general contractor and 1 6 ❑New construction employees(full and/or part-time).* have hired the sub-contractors 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have g. ❑ Demolition working for me in any capacity. employees and have workers' 9. ❑ Building addition [No workers' comp. insurance comp. insurance.; required.] 5. ❑ We are a corporation and its 10.❑ Electrical repairs or additions 3.❑ 1 am a homeowner doing all work officers have exercised their 11.❑Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑Roof repairs insurance required.]t c. 152,§1(4),and we have no SOLAR/PV employees. [No workers' 13.E Other comp. insurance required.] *Any applicant that checks box til most also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they arc doing all work and then hire outside contractors must submit a new of iidavit indicating such. tConlractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer float is providing workers'compensation insurance for my employees. Below is floe policy and job site Information. Insurance Company Name:LIBERTY MUTUAL INSURANCE COMPANY Policy#or Self-ins. Lic.. #:WA7-66D-066265-024 Expiration Date:09/01/2015 Job Site Address: I` �soc 01�6:�10 City/State/Zip:)11,1-Lh cV/�e^ Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). . Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. 1 do hereby certify ander the pains and enalties of perjurp that the Information provider!above is true and correct. 01it C: Phone#: Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4. Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: 3 DATE(MMIDDIYYYY) A 0 CERTIFICATE OF LIABILITY INSURANCE Illo� 0812912014 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: It the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsemen s. PRODUCER C NTACT MARSH RISK 8 INSURANCE SERVICES NAME: 345 CALIFORNIA STREET,SUITE 1300 -INS-N-0-NAftONE - CALIFORNIA CALIFORNIA LICENSE NO.0437153 E-MAIL SAN FRANCISCO,CA 94104 ADDRESS: INSURERIS)AFFORDING COVERAGE_ NAIC a 998301-STND-GAWUE-14.15 INSURER A:Liberty Mutual Fire Insurance Company 16586 INSURED INSURER B:Liberty Insurance Corporation 42404 Ph(650)963.5100 — SofarCity Corporation INSURER C:NIA NIA 3055 ClearYlew Way INSURER D: San Mateo,CA 94402 - w INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: SEA-002440269-02 REVISION NUMBER:4 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REOUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS_. !NSR TYPE OF INSURANCE AODL UBR POLICY NUMBER MM/uDD EFF POLICY EXP LIMITS 117R A GENERAL LIABILITY TB2-661-066265.014 0910112014 09/01/2015 EACH OCCURRENCE $ 1,000,000 X DAMA E TO RENTED 100,000 COMMERCIAL GENERAL LIABILITY PREMISES We occurrence) $ _ CLAIMS-MADE �I OCCUR MED EXP(Any one person) _$ 10,000 _ PERSONAL 6 ADV INJURY $ 1.000'000 GENERAL AGGREGATE S _ 2,000,000 GENT AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OP AGG $ 2,000,000 X POLICY X PRO- LOC Deductible -- J $ 25,000 A AUTOMOBILE LIABILITY AS2-661-066265-044 09/0112014 0910112015 COMBINED SINGLE LIMIT 1,000,000 F=or aceident__ __" X ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS AUTOS -- - X X NON-OWNED P OPPERT t)AMAGE $ HIRED AUTOS AUTOS X Phys.Damage I COMPICOLLDED: $ $1,000!$1,000 UMBRELLA LIAB OCCUR EACH OCCURRENCE EXCESS UAB _ CLAIMS-MADE AGGREGATE _ S D D RETENTION III $ g WORKERS COMPENSATION WA7.66D-066265424 09101/2014 09/0112015 X WC STATU- 0tH- B AND EMPLOYERS'LIABILITY JORYLNI ER ANY PROPRIETORIPARTNERIEXECUTWE Y N WC7-661066265A34(WI) 09!01/2014 09/01/2015 El. EACH ACCIDENT $ 1,000,000 B OFFICERIMEM8ER EXCLUN N/A DED? WC DEDUCTIBLE:$350,000 1.000.000 (Mandatory In NH) E L.DISEASE-EA EMPLOYEE $ It yes,describe under 1,000,000 DESCRIPTION OF P RATIONS below E L DISEASE-POLICY LIMIT $ D CRIPTION OF OPERATIONS l LOCATIONS I VEHICLES (Attach ACORD f01,Additional Remarks Schedule,if more space Is required) E' ence of Insurance. CE TIFICATE HOLDER CANCELLATION SolarCity Corporation SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 3055 Clearview Way THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN San Mateo,CA 94402 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh Risk d Insurance Services Charles Marmolejo ©1988-2010 ACORD CORPORATION. All rights reserved. ACOR 25(2010105) The ACORD name and logo are registered marlts of ACORD Off ce of Consumer Affairs and Business Regulation r� 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 168572 Type: Supplement Card SOLARCITY CORPORATION Expiration: 3/8/2015 CRAIG ELLS _ __ ____ _-___ _ . ._-_-------_. 24 ST. MARTIN STREET BLD 2 UNIT 11 - - - - - - -- - ---- MARLBOROUGH, MA 01752 Update Address and return card.Mark reason for change. SCA, c lora 01.11 [] Address L.] Renewal n Employment [-] Lost Card Office or Consumer Affairs&Business Regulation License or registration valid for individul use only }� k4OME IMPROVEMENT CONTRACTOR before the expiration date. If found return to: s 'I+ Office of Consumer Affairs and Business Regulation Registration: 168572 TYpr 10 Park Plaza-Suite 5170 Expiration: 3/8/2015 Supplement ,ard Boston,MA 02116 SOLARCITY CORPORATION CRAIG ELLS 24 ST MARTIN STREET BLD 2UNI I fNAkLBOR0UGH,MA 01752 Undersecretary Not v lid without signature V I Massachusetts .Department of P.,ot,c Safet-j �- Board of Building Regulations and Stanciarcis (rrnoiukmin Iupurl,s,.r -,Cense CS-107663 CRAIG ELLS 206 BAKER STREET Keene NH 03431 �r,nunlbu„u.r 08/29/2017 Office of Consumer Affairs tind Business Regulation 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 168572 Type: Supplement Card SOLAR CITY CORPORATION Expiration: 3/8/2015 ASTRID BLANCO -�- -- --- -- 24 ST. MARTIN STREET BLD 2 UNIT 11 -- - MARLBOROUGH, MA 01752 Update Address and return card.Mark reason for change. SCAT 0 20M-0f.1i Address ❑ Renewal 0 Employment ❑ Lost Card , n=" Of ice of Consumer Affairs&Business Regulation License or registration valid for individul use only r t, f` before the expiration date. If found return to: 5 ME IMPROVEMENT CONTRACTOR Office of Consumer Affairs and Business Regulation Registration: 168572 Type: 10 Park Plaza-Suite 5170 Expiration: 3/8/2015 Supplement Card Boston,MA 02116 SOLAR CITY CORPORATION ASTRID BLANCO 24 ST MARTIN STREET BLD 2UNI TAANLBOROUGH,MA 01752 Undersecretary Not valid without signature DocuSign Envelope ID:343EFAC3-C586-40A7-ACBB-4601EC1CA033 "-,;SO1arGty. Power Purchase Agreement Here are the key terms of your SolarCity Power Purchase Agreement Date: l0 29 2014 0 11000 20years System installation cost Electricity rate per kWh Agreement term Our Promises to You • We insure,maintain,and repair the System(including the inverter)at no additional cost to you,as specified in the agreement. • We provide 2417 web-enabled monitoring at no additional cost to you,as specked in the agreement. • We warranty your roof against leaks and restore your roof at the end of the agreement,as specified in the agreement. • The rate you pay for electricity,exclusive of taxes,will never increase by more than 2.90%per year. • The pricing in this PPA is valid for 30 days after 10/29/2014. • We are confident that we deliver excellent value and customer service.As a result, you are free to cancel anytime at no charge prior to construction on your home. Estimated First Year Production 13,585 kWh Customer's Name & Service Address Exactly as it appears on the utility bill Customer Name and Address Customer Name Installation Location Nancy Sarro 44 Equestrian Dr 44 Equestrian Dr North Andover, MA 01845 North Andover, MA 01845 Options for System purchase and transfer: Options at the end of the 20 year term: • If you move,you may transfer this agreement to the purchaser of your • SolarCity will remove the System at no cost to you. Home,as specified in the agreement. • You can upgrade to a new System with the latest solar • At certain times,as specified in the agreement,you may purchase the technology under a new contract. System. • You may purchase the System from SolarCity for its fair • These options apply during the 20 year term of our agreement and not market value as specified in the agreement, beyond that term. • You may renew this agreement for up to ten(10)years in two(2)five(5)year increments. 3055 CLEARVIEW WAY, SAN MATEO, CA 94402 888.SOL.CITY 1888.765.2489 SOLARCITY.COM MA HIC 168572/EL-1136MR Document Generated on 10/29/2014 �■ rml 0 363131 5wnwl DocuSign Envelope ID:343EFAC3-C586-40A7-ACBB-4601EC1CA033 22. NOTICE OF RIGHT TO CANCEL. I have read this Power Purchase Agreement and the Exhibits in their YOU MAY CANCEL THIS CONTRACT AT ANY TIME PRIOR TO entirety and I acknowledge that I have received a complete copy of this MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE DATE Power Purchase Agreement. YOU SIGN THIS CONTRACT. SEE EXHIBIT 1,THE ATTACHED NOTICE OF CANCELLATION FORM FOR AN Customer's Name:Nancy Sarro EXPLANATION OF THIS RIGHT. oocusignea by: I'10� 23.ADDITIONAL RIGHTS TO CANCEL. Signature: IN ADDITION TO ANY RIGHTS YOU MAY HAVE TO CANCEL THIS PPA UNDER SECTION 22,YOU MAY ALSO CANCEL Date: 10/29/2014 THIS PPA AT NO COST AT ANY TIME PRIOR TO COMMENCEMENT OF CONSTRUCTION ON YOUR HOME. 24. Pricing The pricing in this PPA is valid.for 30 days after 10/29/2014. If you Customer's Name: don't sign this PPA and return it to us on or prior to 30 days after 10/29/2014,SolarCity reserves the right to reject this PPA unless Signature: you agree to our then current pricing. Date: =� SolarCity. Power Purchase Agreement SOLARCITY APPROVED Signature: ;► �� � LYNDON RIVE,CEO (PPA) Power Purchase Agreement RY. Date: 10/29/2014 0 Solar Power Purchase Agreement version 8.1.1 363131 N . Version#39.5 �o,%SolarCit . OF y �H 3055 Clearview Way, San Mateo, CA 94402 '' Y00 JIN ¢_ (888)-SOL-CITY (765-2489) 1 www.solarcity.com K �n October 31, 2014 NI H No.4 7 Project/Job# 0181270 RE: CERTIFICATION LETTER AL Project: Sarro Residence Dig ita I ly y Yoo Jin Kim 44 Equestrian Dr North Andover, MA 01845 Date: 2 14.10.31 13:55:33 To Whom It May Concern, -07'00' A jobsite survey of the existing framing system was performed by a site survey team from SolarCity. Structural review was based on site observations and the design criteria listed below: Design Criteria: -Applicable Codes = MA Res. Code,8th Edition,ASCE 7-05,and 2005 NDS - Risk Category = II -Wind Speed = 100 mph, Exposure Category C -Ground Snow Load = 50 psf -MP1: Roof DL= 8 psf,Roof LL/SL= 35 psf(Non-PV Areas), Roof LL/SL= 21.5 psf(PV Areas) -MP2: Roof DL= 8 psf, Roof LL/SL= 35 psf(Non-PV Areas), Roof LL/SL= 21.5 psf(PV Areas) Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.33365 < 0.4g and Seismic Design Category(SDC) =C < D On the above referenced project,the components of the structural roof framing impacted by the installation of the PV assembly have been reviewed. After this review it has been determined that the existing structure is adequate to withstand the applicable roof dead load,PV assembly load,and live/snow loads indicated in the design criteria above. I certify that the structural roof framing and the new attachments that directly support the gravity loading and wind uplift loading from PV modules have been reviewed and determined to meet or exceed structural strength requirements of the MA Res.Code,8th Edition. Please contact me with any questions or concerns regarding this project. Sincerely, Yoo Jin Kim, P.E. Professional Engineer Main: 888.765.2489,x5743 email: ykim@solarcity.com 3055 Clearview Way San Mateo,CA 94402 T(650)638-1028 (888)SOL-CITY F(650)638-1029 solarcity.com +d r -4, 1 t.4 i%M t• '41 ,1 .Z, : (.�.^.. Iio,n.. «F -4, .... � a uA n: n,?.2.MG WH t.r C� l 2 if.a4f'3,FA r!!i.t:l �<m H 'Cn KA .,1 .i:AF' 1• . .1 me 1 ,.,hln rt 1 10.31.2014 TM Version#39.5 o St��af Clt SleekMount PV System � p�'Q y Structural Design Software PROJECT INFORMATION &TABLE OF CONTENTS Project Name: Sarro Residence AHJ: North Andover Job Number: 0181270 Building Code: MA Res.Code, 8th Edition Customer Name: Sarro, Nancy Based On: IRC 2009/IBC 2009 Address: 44 Equestrian Dr ASCE Code: ASCE 7-05 City/State: North Andover, MA Risk Category: II Zip Code 01845 Upgrades Req'd? No Latitude/Longitude: 42.642420 -71.046971 Stamp Req'd? Yes SC Office: Wilmington PV Designer: Rob Solaski Calculations: Ran Atwell EOR: Yoo Jin Kim P.E. Certification Letter 1 Project Information, Table Of Contents, &Vicinity Map 2 Structure Analysis (Loading Summary and Member Check) 3 Hardware Design (PV System Assembly) 4 Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.33365 < 0.4g and Seismic Design Category(SDC) =C < D 112-MILE VICINITY MAP D . ..s- Commonwealth of Massachusetts • D• - Agency Equestrian Dr, North Andover, MA 01845 Latitude:42.64242,Longitude: -71.046971,Exposure Category:C LOAD ITEMIZATION - MP1 PV System Load PV Module Weight(psf) 2.5 psf Hardware Assembly Weight s 0.5 psf PV System Weight s 3.0 psf Roof Dead Load Material Load Roof Category Description MPI Roofing Type Comp Roof ( 1 Layers) 2.5 psf Re-Roof to 1 Layer of Comp? No Underlayment Rooting Paper 0.5 psf Plywood Sheathing Yes 1:5 psf Board Sheathing None Rafter Size and Spacing 2 x 8 @ 16 in. O.C. 2.3 psf Vaulted Ceiling No Miscellaneous Miscellaneous Items 1.2 Dsf Total Roof Dead Load 8 Psf(1MP1) 1 8.0 Psf Reduced Roof LL Non-PV Areas Value ASCE 7-05 Roof Live Load Lo 20.0 psf Table 4-1 Member Tributary Area At < 200 sf Roof Slope 7/12 Tributary Area Reduction Rl 1 Section 4.9 Sloped Roof Reduction R2 0.85 Section 4.9 Reduced Roof Live Load Lr L,= Lo(RI)(R2) I Equation 4-2 Reduced Roof Live Load Lr 17 psf MPi 17.0 PsF Reduced Ground/Roof Live/Snow Loads Code Ground Snow Load py 50.0 psf ASCE Table 7-1 Snow Load Reductions Allowed? Yes Effective Roof Slope 300 I Horiz. Distance from Eve to Ridge W 18.5 ft Snow Importance Factor IS 1.0 Table 1.5-2 Snow Exposure Factor Ce Partially Exposed Table 7-2 1.0 Snow Thermal Factor Ct All structures except as indicated otherwise Table 7-3 1.0 Minimum Flat Roof Snow Load(w/ 35.0 psf 7.3.4&7.10 Rain-on-Snow Surcharge) Pf-min Flat Roof Snow Load Pf pf= 0.7(Ce)(Ct)(I) pg; pf i pf-min Eq: 7.3-1 35.0 psf 70% ASCE Design Sloped Roof Snow Load Over Surroundinq Roof Surface Condition of Surrounding All Other Surfaces Roof fOOf 1.0 Figure 7-2 Design Roof Snow Load Over Ps-roof= QCs-roof)Pf ASCE Eq: 7.4-1 Surrounding Roof Ps-roof 35.0 psf 70% ASCE Design Sloped Roof Snow Load Over PV Modules Surface Condition of PV Modules C Unobstructed Slippery Surfaces 5_pv 0.6 Figure 7-2 Design Snow Load Over PV PS-PV= (Cs-pv)Pf ASCE Eq:7.4-1 Modules PS-PV 21.6 psf 43% COMPANY PROJECT WoodWorkso SOFIWARFFOR WOOD OFSICN Oct. 31, 2014 13:18 MP1.wwb Design Check Calculation Sheet WoodWorks Sizer 10.1 Loads: Load Type Distribution Pat- Location [ft] Magnitude Unit tern Start End Start End DL Dead Full Area No 8.00 (16.0) * psf SL Snow Partial Area Yes 0.00 1.17 35.00 (16.0) * psf PV Dead Full Area No 3.00 (16.0) * psf SL-PV Snow Partial Area Yes 1.17 14.00 21.60 (16.0) * psf SL2 Snow Partial Area Yes 14.00 16.00 35.00 (16.0) * ,psf *Tributary Width (in) Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) : 18'-10.8" 0' 1'-2" 16' Unfactored• Dead 146 126 Snow 272 246 Factored: Total 418 372 Bearing: F'theta 516 516 Capacity Joist 677 387 Supports 586 586 Anal/Des Joist 0.62 0.96 Support 0.71 0.63 Load comb #2 #4 Length 0.50* 0.50* Min req'd 0.36** 0.50* Cb 1.75 1.00 Cb min 1.75 1.00 Cb support 1.25 1.25 Fcp sup 625 625 *Minimum bearing length setting used: 1/2"for end supports and 1/2"for interior supports **Minimum bearing length governed by the required width of the supporting member. MP1 Lumber-soft, S-P-F, No.1/No.2, 2x8 (1-1/2"x7-1/4") Supports:All-Timber-soft Beam, D.Fir-L No.2 Roof joist spaced at 16.0"c/c; Total length: 18'-10.8"; Pitch: 7/12; Lateral support: top=full, bottom=at supports; Repetitive factor: applied where permitted (refer to online help); WARNING: Member length exceeds typical stock length of 18.0[ft] F71 I WOodWorkS® Sizer SOFTWARE FOR WOOD DESIGN MP1.wwb WoodWorksO Sizer 10.1 Page 2 Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2012 : Criterion Analysis Value Design Value Analysis/Design Shear fv = 40 Fv' = 155 fv/Fv' = 0.26 Bending(+) fb = 1154 Fb' = 1389 fb/Fb' = 0.83 Bending(-) fb = 40 Fb' = 576 fb/Fb' = 0.07 Live Defl'n 0.64 = L/322 1.14 = L/180 0.56 Total Defl'n 1.19 = L/173 1.72 = L/120 0.69 Additional Data: FACTORS: F/E(psi)CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC# Fv' 135 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 2 Fb'+ 875 1.15 1.00 1.00 1.000 1.200 1.00 1.15 1.00 1.00 - 4 Fb' - 875 1.15 1.00 1.00 0.415 1.200 1.00 1.15 1.00 1.00 - 2 Fcp' 425 - 1.00 1.00 - - - - 1.00 1.00 - - E' 1.4 million 1.00 1.00 - - - - 1.00 1.00 - 4 Emin' 0.51 million 1.00 1.00 - - - - 1.00 1.00 - 4 CRITICAL LOAD COMBINATIONS: Shear : LC #2 = D+S, V = 320, V design = 290 lbs Bending(+) : LC #4 = D+S (pattern: sS) , M = 1263 lbs-ft Bending(-) : LC #2 = D+S, M = 43 lbs-ft Deflection: LC #4 = (live) LC #4 = (total) D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake All LC's are listed in the Analysis output Load Patterns: s=S/2, X=L+S or L+Lr, _=no pattern load in this span Load combinations: ASCE 7-10 / IBC 2012 CALCULATIONS: Deflection: EI - 67e06 lb-in2 "Live" deflection = Deflection from all non-dead loads (live, wind, snow...) Total Deflection = 1.50 (Dead Load Deflection) + Live Load Deflection. Bearing: Allowable bearing at an angle F'theta calculated for each support as per NDS 3 .10.3 Design Notes: 1. WoodWorks analysis and design are in accordance with the ICC International Building Code(IBC 2012), the National Design Specification (NDS 2012), and NDS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Continuous or Cantilevered Beams: NDS Clause 4.2.5.5 requires that normal grading provisions be extended to the middle 2/3 of 2 span beams and to the full length of cantilevers and other spans. 4. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. 5. SLOPED BEAMS: level bearing is required for all sloped beams. 6. FIRE RATING: Joists, wall studs, and multi-ply members are not rated for fire endurance. 7. The critical deflection value has been determined using maximum back-span deflection. Cantilever deflections do not govern design. CALCULATION OF DESIGN WIND LOADS - MP1 , Mounting Plane Information Roofing Material Comp Roof PV System Type SolarCity SleekMountTM Spanning Vents No Standoff Attachment Hardware Com Mount T e C Roof Slope 300 Rafter Spacing 16"O.C. Framing Type Direction Y-Y Rafters Purlin Spacing X-X Purlins Only NA Tile Reveal Tile Roofs Only NA Tile Attachment System Tile Roofs Only NA .Standing Seam Spacing SM Seam Only NA Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 100 mph Fig. 6-1 Exposure Category C Section 6.5.6.3 Roof Style Gable Roof Fig.6-11B/C/D-14A/B Mean Roof Height h 25 ft I Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.95 Table 6-3 Topographic Factor KA 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 1.0 Table 6-1 Velocity Pressureqh =0.00256(Kz)(Krt)(Kd)(V^2)(I) q" 20.6 sf Equation 6-15 Wind Pressure Ext. Pressure Coefficient U GC -0.95 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient Down GC 0.88 Fig.6-11B/C/D-14A/B Design Wind Pressure p p = q"(GC) Equation 6-22 Wind Pressure U -19.6 psf Wind Pressure Down 18.0 Psf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 64" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 17 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T-actual -310 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 62.0% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 48" 64" Max Allowable Cantilever Portrait 20" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 21 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T-actual -388 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 77.5% LOAD ITEMIZATION - MP2 PV System Load PV Module Weight(psf) 2.5 psf Hardware Assembly Weight s 0.5 psf PV System Weigh s 3.0 psf Roof Dead Load Material Load Roof Category Description MP2 Roofing Type Comp Roof ( 1 Layers) 2.5 psf Re-Roof to 1 Layer of Comp? No Underlayment Roofing Paper 0.5 psf Plywood Sheathing Yes, 1.5 psf Board Sheathing None Rafter Size and Spacing 2 x 8 @ 16 in. O.C. 2.3 psf Vaulted Ceiling No Miscellaneous Miscellaneous Items 1 1.2 psf Total Roof Dead Load 8 psf MP2 8.0 Psf Reduced Roof LL Non-PV Areas Value ASCE 7-05 Roof Live Load Lo 20.0 psf Table 4-1 Member Tributary Area At < 200 sf Roof Slope 7/12 Tributary Area Reduction Rl 1 Section 4.9 Sloped Roof Reduction RZ 0.85 Section 4.9 Reduced Roof Live Load Lr L, = Lo(Rl)(R2) Equation 4-2 Reduced Roof Live Load Lr 17 psf MP2 17.0 Psf Reduced Ground/Roof Live/Snow Loads Code Ground Snow Load p9 50.0 psf ASCE Table 7-1 Snow Load Reductions Allowed? Yes Effective Roof Slope 300 I Horiz. Distance from Eve to Ridge W 17.2 ft Snow Importance Factor IS 1.0 Table 1.5-2 Snow Exposure Factor Ce Partially Exposed Table 7-2 1.0 Snow Thermal Factor Ct All structures except i s0 indicated otherwise Table 7-3 Minimum Flat Roof Snow Load(w/ Pf-min 35.0 psf 7.3.4&7.10 Rain-on-Snow Surcharge) Flat Roof Snow Load Pf pf= 0.7(Ce)(Ct) (I) pg; pf>_ pf-min Eq: 7.3-1 35.0 psf 70% ASCE Design Sloped Roof Snow Load Over Surround�n Roof Surface Condition of Surrounding All Other Surfaces Roof Cs Figure 7-2 1.0 Design Roof Snow Load Over ro PS- of= (Cs-roof)Pf ASCE Eq: 7.4-1 SurroundingRoof Ps-roof 35.0 psf 70% ASCE Design Sloped Roof Snow Load Over PV Modules Unobstructed 5016 pery Surfaces Figure 7-2 Surface Condition of PV Modules CS_P" Design Snow Load Over PV PS-PV= (Cs-pv)Pf ASCE Eq: 7.4-1 Modules PS P" 21.6 psf 43% COMPANY PROJECT WoodWorkso WMAIF FOR w00n DFSN:N Oct. 31, 2014 13:18 MP2.wwb Design Check Calculation Sheet WoodWorks Sizer 10.1 Loads: Load Type Distribution Pat- Location [ft] Magnitude Unit tern Start End Start End DL Dead Full Area No 8.00 (16.0) * psf SL Snow Full Area Yes 35.00 (16.0) * psf PV Dead Full Area No 3.00 (16.0) * psf *Tributary Width (in) Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) : 17'-6.6„ 0' 1'-2" 14'-10" Unfactored: Dead 136 116 Snow 375 319 Factored: Total 512 435 Bearing: F'theta 516 516 Capacity Joist 677 435 Supports 586 659 Anal/Des Joist 0.76 1.00 Support 0.87 0.66 Load comb #2 #4 Length 0.50* 0.56 Min req'd 0.44** 0.56 Cb 1.75 1.00 Cb min 1.75 1.00 Cb support 1.25 1.25 Fcp sup 625 625 "Minimum bearing length setting used: 1/2"for interior supports "Minimum bearing length governed by the required width of the supporting member. MP2 Lumber-soft, S-P-F, No.1/No.2, 2x8 (1-1/2"x7-1/4") Supports:All-Timber-soft Beam, D.Fir-L No.2 Roof joist spaced at 16.0"c/c; Total length: 17'-6.6"; Pitch: 7/12; Lateral support: top=full, bottom=at supports; Repetitive factor: applied where permitted (refer to online help); WOodWorkS® Sizer SOFTWARE FOR WOOD DESIGN MP2.wwb WoodWorks®Sizer 10.1 Page 2 Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2012 : Criterion Analysis Value Design Value Analysis/Design Shear fv = 48 Fv' = 155 fv/Fv' = 0.31 Bending(+) fb = 1344 Fb' = 1389 fb/Fb' = 0.97 Bending(-) fb = 40 Fb' = 619 fb/Fb' = 0.06 Live Defl'n 0.73 = L/260 1.05 = L/180 0.69 Total Defl'n 1.12 = L/168 1.58 = L/120 0.71 Additional Data: FACTORS: F/E(psi)CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC# Fv' 135 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 2 Fb'+ 875 1.15 1.00 1.00 1.000 1.200 1.00 1.15 1.00 1.00 - 4 Fb' - 875 1.15 1.00 1.00 0.446 1.200 1.00 1.15 1.00 1.00 - 2 Fcp' 425 - 1.00 1.00 - - - - 1.00 1.00 - - E' 1.4 million 1.00 1.00 - - - - 1.00 1.00 - 4 Emin' 0.51 million 1.00 1.00 - - - - 1.00 1.00 - 4 CRITICAL LOAD COMBINATIONS: Shear : LC #2 = D+S, V = 378, V design = 349 lbs Bending(+) : LC #4 = D+S (pattern: sS) , M = 1472 lbs-ft Bending(-) : LC #2 = D+S, M = 43 lbs-ft Deflection: LC #4 = (live) LC #4 = (total) D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake All LC's are listed in the Analysis output Load Patterns: s=S/2, X=L+S or L+Lr, _=no pattern load in this span Load combinations: ASCE 7-10 / IBC 2012 CALCULATIONS: Deflection: EI = 67e06 lb-int "Live" deflection = Deflection from all non-dead loads (live, wind, snow...) Total Deflection = 1.50 (Dead Load Deflection) + Live Load Deflection. Bearing: Allowable bearing at an angle F'theta calculated for each support as per NDS 3 .10.3 Design Notes: 1. WoodWorks analysis and design are in accordance with the ICC International Building Code(IBC 2012), the National Design Specification (NDS 2012), and NDS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Continuous or Cantilevered Beams: NDS Clause 4.2.5.5 requires that normal grading provisions be extended to the middle 2/3 of 2 span beams and to the full length of cantilevers and other spans. 4. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. 5. SLOPED BEAMS: level bearing is required for all sloped beams. 6. FIRE RATING: Joists, wall studs, and multi-ply members are not rated for fire endurance. 7. The critical deflection value has been determined using maximum back-span deflection. Cantilever deflections do not govern design. CALCULATION OF DESIGN WIND LOADS - MP2 Mounting Plane Information Roofing Material Comp Roof PV System Type SolarCity SleekMountTM Spanning Vents No Standoff Attachment Hardware Comp Mount T e C Roof Slope 300 Rafter Spacing 16"O.C. Framin Type Direction Y-Y Rafters Purlin Spacing X-X Purlins Only NA Tile Reveal Tile Roofs Only NA Tile Attachment System Tile Roofs Only NA Standing Seam Spacing SM Seam Only NA Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 100 mph Fig. 6-1 Exposure Category C Section 6.5.6.3 Roof Style Gable Roof Fig.6-11B/C/D-14A/B Mean Roof Height h 15 It Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 Table 6-3 Topographic Factor KA 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 1.0 Table 6-1 Velocity Pressure qh qh = 0.00256(Kz)(Krt)(Kd)(V^2)(I) Equation 6-15 18.5 psf Wind Pressure Ext. Pressure Coefficient U GC -0.95 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient Down GC 0.88 Fig.6-11B/C/D-14A/B Design Wind Pressure P p =qh(GC ) Equation 6-22 Wind Pressure U -17.6 psf Wind Pressure Down 16.2 psf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 64" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 17 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T-actual -275 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 55.1% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 48" 64" Max Allowable Cantilever Portrait 20" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 21 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T-actual -345 lbs _ Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 68.9% s r ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. 1 CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING P01 POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 THREE LINE DIAGRAM LICENSE GENERAL NOTES Cutsheets Attached GEN #168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION ELEC 1136 MR OF THE MA STATE BUILDING CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: ZEP SOLAR AHJ: North Andover REV BY DATE COMMENTS REV A NAME DATE COMMENTS UTILITY: National Grid USA (Massachusetts Electric) CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: J B-0181270 0 0 MEMISE OMNER: DESCRIPTION: DESIGN: \\, CONTAINED SHALL NOT BE USED FOR THE SARRO, NANCY SARRO RESIDENCE Rob Solaski =;;,So�arCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: W. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 44 EQUESTRIAN DR 10.71 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S MooutEs NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH s THE SALE AND USE OF THE RESPECTIVE (42) CANADIAN SOLAR # CS6P-255PX 24 St. Mmtin Drive,Building 2,uolt 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REN DATE: MarlborouL (650)638-1028 F: (65052 )638-1029 PERMISSION OF SOLARCITY INC Multiple Inverters 6174353524 COVER SHEET PV 1 10/31/2014 (BBB)—SOL-CITY(765-2489) ww..solorcity.com PITCH: 30 ARRAY PITCH:30 MP1 AZIMUTH: 141 ARRAY AZIMUTH: 141 PITCH: 30 ARRAY PITCH:30 MP2 AZIMUTH: 141 ARRAY AZIMUTH: 141 MATERIAL: Comp Shingle STORY: 1 Story PITCH: 15 ARRAY PITCH:15 MP3 AZIMUTH: 141 ARRAY AZIMUTH: 141 m MATERIAL: Comp Shingle STORY: 1 Story BPITCH: 30 ARRAY PITCH:30 CD DRIVEWAY MP4 AZIMUTH:231 ARRAY AZIMUTH: 231 MATERIAL: Comp Shingle STORY: 1 Story 0 OF a IIL y Mai LEGEND Y00 AN K V1 (E) UTILITY METER & WARNING LABEL No. Cos INVERTER W/ INTEGRATED DC DISCO a Ing & WARNING LABELS 4 © DC DISCONNECT & WARNING LABELS Digitally gne y Yoo Jin Kim a Date:2014.10.31 13:55:52 © AC DISCONNECT & WARNING LABELS -07'00' Front Of House DC JUNCTION/COMBINER BOX & LABELS MP4 Q DISTRIBUTION PANEL & LABELS 4 d Lc LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER A Q STANDOFF LOCATIONS _`T__, CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR D /'E;--� GATE/FENCE Q HEAT PRODUCING VENTS ARE RED OInv Inv r, �� INTERIOR EQUIPMENT IS DASHED ACL-"J © LC SITE PLAN Scale: 3/32" = 1' 01' 10' 21' PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN ,�NUMBER. JB-01 81270 00 ��� CONTAINED SHALL NOT BE USED FOR THE SARRO, NANCY SARRO RESIDENCE Rob Solaski �,��`" BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: � ,S��a f City NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount T :, Type C 44 EQUESTRIAN DR 10.71 KW PV ARRAY '® PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St. Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (42) CANADIAN SOLAR # CS6P-255PXSOLARCITY PAGE NAME SHEET: REV DAIS Marlborough,MA 01752 PERMISSION EQUIPMENT,SOLAT, WITHOUT THE WRITTEN INVERTER: T. (650)638-1028 R (650)638-1029 PERMISSION OF SOLARgTY INC. Multiple Inverters 6174353524 SITE PLAN PV 2 10/31/2014 (888)—SOL—CITY(765-2489) www.solarcity.com a OF�u Y00 JIN S 1 S1 K VI No.4 4" — � 13'-8" 01 14' �o" AL 1'— (E) LBW Digital y Yoo Jin Kim 11— (E) LBW A SIDE VIEW OF MP1 NTs -07'00'014.10.31 13:55:45 B SIDE VIEW OF MP2 NTs MPJ X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 64" 24" STAGGERED LANDSCAPE 64" 24" STAGGERED PORTRAIT 48" 20" PORTRAIT 48" 20" RAFTER 2X8 @ 16"OC ROOF AZI 141 PITCH 30 STORIES: 2 ROOF AZI 141 PITCH 30 ARRAY AZI 141 PITCH 30 RAFTER 2X8 @ 16"OC ARRAY AZI 141 PITCH 30 STORIES: 1 C.I. 2x8 @16"OC Comp Shingle C.J. 2X8 @16"OC Comp Shingle PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. ZEP COMP MOUNT C ZEP FLASHING C (3) (3) INSERT FLASHING. (E) COMP. SHINGLE (4) PLACE MOUNT. (1) (E) ROOF DECKING (2) INSTALL LAG BOLT WITH 5/16" DIA STAINLESS (5) L5)T) SEALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH WITH SEALING WASHER (6) BOLT & WASHERS. (2-1/2" EMBED, MIN) (E) RAFTER 4-5T� JB-01 81270 D O PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN IDB NUMBER: SARRO, NANCY SARRO RESIDENCE solareCity. CONTAINED SHALL NOT BE USED FOR THE Rob Solaski �\,:! BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: A,jw NOR MALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 44 EQUESTRIAN DR 10.71 KW PV ARRAY PART TO OTHERS OUTSIDE THE NMODULES: NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTIONECTIONPATAT H THE SALE AND USE OF THE RESPECTIVE (42)_ CANADIAN SOLAR # CS6P-255PX 24 St. Martin Drive, MA 01g 2 Unit 11 PAGE NAME SHEET: REN DATE SOLARCITY EQUIPMENT, WITHOUT THE WRITR?I INVERTER: T: (650)Marlborough38-102 'F A(650)636 -1029 PERMISSION OF SOLARCITY INC. Multiple Inverters 6174353524 STRUCTURAL VIEWS PV 3 10/31/2014 (BBB)-SCI-CITY(765-2489) www.8alarcity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE _l2aaeLAumbjer-11E Inv 1: DC Un rounded INXJL-(1)SOLAREDGE 60DOA-USD0OSNR • A (42)CANADIAN SOLAR CS6P-255PX GEN #168572 ODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:05062224 Inv 2: DC Ungrounded n er a IyL(`4. ZELEnable_d ELEC 1136 MR Underground Service Entrance Tie-In: Supply Side Connection INV 2-(1)SOLAREDGE�SE300DA-USOOOSN 2 LAg� B Inverter, 30 W, 240V, 97.5X; w/Unifed D.-co and ZB,RGM,AFCI Voc: 37,4 Vpmax: 30.2 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL E 20OA/2P MAIN CIRCUIT BREAKER SolarCity (E) WIRING CUTLER-HAMMER BRYANT Inverter 1 Disconnect CUTLER-HAMMER (N) 125A Load Center 5 1 20OA/2P 10 Disconnect 9 7 SOLAREDGE DC+ B 50A D SE6000A-USOOOSNR2 DC_ MP 1: 1x14 C 35A/2P - - EGc II A Lt 2aov r--------- - - ---------------- B L2 DC+ I N DG I 4 2 I (E) LOADS GND ____ GND _ _ EGC/ DC+ DC+ - - -------------- GEC ---T� Dc DC_ MP 1: 1x13 I 13) Z � r--- LO J I I GND __ N II EGC--- ---------V(11-)Co-nd-uit-Kit;-3-/4-'E-MT I Inverter 2 T EGC/GEC-, I I s SOLAREDGE I I i SE3000A-USOOOSNR2 L 1 20A/2P a v zao GEC --r--� I L2 TO 120/240V i i i N 6 F 3 I SINGLE PHASE I I L_ Eca Dc+ Dc+ - - I UTILITY SERVICE I I ___------------- - GEC ---I I I N Dc DC- MP : 1x15 --------------------------- ---,----- - EGC-------------- ---t I I I I I PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Voc* = MAX VOC AT MIN TEMP POI (2)Ground Rod; 5/8' x 8', Copper B (1)CUTLER-HAMMER �!DG222NRB /f\� A (1)SolarCi, 4 STRING JUNCTION BOX D� -(2)ILSCO#IPC 4/0-/6 Disconnect; 60A, 24OVac, Fusible, NEMA 3R /y 2x2 STR GS, UNFUSED, GROUNDED Insulation Piercing Connector; Main 4/0-4, Tap 6-14 -(1)CUTLER- AMMER DGIODNB `, D Grounds eutral it; 60-100A, General Duty(DG) P V (42)SOLAREDGE 4P300-2NA4AZS Load #BR816L125RP -(1)CUTLER-HAMMER #DS16FK PowerBox Optimizer, 30OW, H4, DC to DC, ZEP Load Center, 125A, 120/24OV, NEMA 3R Class R Fuse Kit -(1)CUTLER-HAMMER #BR235 -(2)FERRAZ SHAWMUT#TRSOR PV BACKFEED OCP nd (1)AWG#s, Solid Bare Copper Breaker, 35A 2P, 2 Spaces Fuse; 50A, 25OV, Class RK5 -(1)Ground Rod; 5/8' x 8% Copper -(1)CUTLER-HAMM R #BR220 Breaker, 20A 2P, 2 Spaces C (I)CUTLER-HAMMER #DG222UR8 N ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION N0. 2, ADDITIONAL SCDisconnect; 60A, 24OVoc, Non-Fusible, NEMA 3R ( ) SUPPLY SIDE CONNECTION. DISCONNECTING MEANS SHALL BE SUITABLE -(1)CUTLER- AMMER DG10ONB ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE AS SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. Ground�leutral Kit; 60-100A, General Duty(DG) pF(i AWG#8, THWN-2, Block (1)AWG#8, THWN 2, Block (1)AWG 110, THWN-2, Black Voc* =500 VDC Isc -15 ADC (2)AWG#10, PV WIRE, Black Voc* =500 VDC Isc =15 ADC O (1)AWG 18, THWN-2, Red O Lr`L(1)AWG#8, THWN 2, Red ®k(I)AWP (1)AWG 110, THWN-2, Red Vmp =350 VDC Imp=9.35 ADC O (1)AWG#6, Solid Bare Copper EGC Vmp =350 VDC Imp=10.07 ADC (1)AWG #8, THWN-2, White NEUTRAL Vmp =240 VAC Imp=37.5 AAC (1)AWG#10, THWN 2, White NEUTRAL VmP =240 VAC Imp=25 AAC #10, THWN-2,,Green EGC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LJ . . . . ..70)AWG#8,.THWN-2,.Green _. EGC/GEC (1)Conduit,Kit;.3/,'.EMT. . . . . . . . . . . . . . . . .-(1)AWG#8,.TFIWTI-2,.Green . . EGC/GEC.-(1)Conduit.Kit;.3/4�.EMT. . . . . . . , , , (1)AWA;#10, THWN-2, Black Voc* =500 VDC Isc =15 ADC (2)AWG#10, PV WIRE, Black Voc* =500 VDC Isc =15 ADC (1)AWG#6, THWN-2, Black (1)AWG#10, THWN-2, Black O (1)AWG#10, THWN-2, Red Vmp =350 VDC Imp=10.07 ADC O (1)AWG#6, Solid Bare Copper EGC Vmp =350 VDC Imp=9.35 ADC ®�(1)AWG 16,AWG THWN-2, Red ®L-L(1)AWG#10, THWN-2, Red (i)AWG#10, THWN-2,,Green EGC. . . . . . . . .. II�_LL ( ) #6, THWN-2, White NEUTRAL Vmp =240 VAC Imp=37.5 AAC (1)AWG#10, THWN-2, White NEUTRAL Vmp =240VAC Imp=12.5 AAC (1)AWG 110, THWN-2, Black Voc* =500 VDC Isc =15 ADC (2)AWG#10, PVIMRE Black Voc* =500 VDC Isc =15 ADC . . . . . ..-(1)AN#§,,Solid Bare.Copper. AEP. . . .-(1)Conduit.Kit;.3/47.EMT. . . . . . . . . . . . . . . . .-(1)AWG#8,_THWN-2,,Green . . EGC/GEC.-(i)Conduit.Kit;.3/4".EMT. . _ . . . . , .. © (1)AWG#10, THWN-2, Red Vmp =350 VDC Imp=10.79 ADC O (1)AWG#6, Solid Bare Copper EGC Vmp =350 VDC Imp=10.79 ADC (1)AWG#10, THWN-2,.Green, , EGC, . . -(1)Condgit.Kit;.3/4'.EMT. . . . . , , , , IJJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . JB-01 81270 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER \I„�OI���I� m CONTAINED SHALL NOT BE USED FOR THE SARRO, NANCY SARRO RESIDENCE Rob Solaski " BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: .,� �/ NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 44 EQUESTRIAN DR 10.71 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S MaOULEs NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St. Martin Drive, Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (42) CANADIAN SOLAR # CS6P-255PXSOLARCITY PAGE NAME SHEET: REV DATE Marlborough,MA 01752 PERMISSION EQUIPMENT,SOLAR, WITHOUT THE WRITTEN INVERTER: t (650)638-1028 F: (650)638-1029 PERMISSION OF SOLARgTY INC. Multiple Inverters 6174353524 THREE LINE DIAGRAM PV 4 10/31/2014 (888)-SOL-CITY(765-2489) www.solarcity.com WARNING;PHOTOVOLTAIC POWER SOURCE _ •" WARNING ;'_ WARNING CLabel Location: Label Location: Label Location: ode: Code: NEC 690.31.G.3 ELECTRIC SHOCK HAZARDNEC ELECTRIC SHOCK HAZARD NEC . DONOT TOUCH TERMINALS THE DC CONDUCTORS OF THIS Label • • TERMINALS ON BOTH LINE AND PHOTOVOLTAIC SYSTEM ARETO BE USED WHEN PHOTOVOLTAIC DCLOADNTH OPENPOSNTIONIZED UNGROUNDED ANDVERTERIS DISCONNECTPer Code: . -_.. MAYBE ENERGIZEDUNGROUNDED NEC .'1 r. Label • • •- Location: . .� ��WARNING Code:Per MAXIMUM POWER- q INVERTER OUTPUT POINT CURRENT(Imp}- Per Code: CONNECTION 690.64.B.7 MAXIMUM POWER- VNEC 690.53DO NOT RELOCATE POINT VOLTAGE(Vmp}_ M SYSTEM• � THIS OVERCURRENT MA VOLTAGE(Voc)_V :DEVICE SHORT-CIRCUIT CURRENT(Isc}_q Label • • PHOTOVOLTAIC POINT OF '• Label • • INTERCONNECTIONPer •. WARNING WARNING: ELECTRIC SHOCKNEC 690.17.4; NEC • Per HAZARD. DO NOT TOUCH Code: TERMINALS.TERMINALS ON ELECTRICAL SHOCK HAZARD 690.17(4) BOTH THE LINE AND LOAD SIDE DO NOT TOUCH TERMINALSMAY BE ENERGIZED IN THE OPEN TERMINALS ON BOTH LINE AND POSITION. FOR SERVICE LOAD SIDES MAYBE ENERGIZED DE-ENERGIZE BOTH SOURCE IN THE.OPEN POSITION AND MAIN BREAKER. OC VOLTAGE iS PV POWER SOURCE ALWAYS PRESENT WHEN MAXIMUM AC - A SOLAR MODULES ARE OPERATING CURRENT EXPOSED TO SUNLIGHT MAXIMUM AC OPERATING VOLTAGE V Label • • WARNINGLocation: Per ELECTRIC-SHOCK HAZARD �.; CAUTION ' Code:NEC IF A GROUND FAULT IS.INDICATED PHOTOVOLTAIC SYSTEM NORMALLY GROUNDED CIRCUIT IS BACKFED 690.64.13.4 CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED Label • • Location:Label (POI) _ PHOTOVOLTAIC AC PO DUAL POWER SOURCECode: • DISCONNECT Per Code: PHOTOVOLTAOICSYSTEM 690.64.13.4Conduit NEC 6.014.C.2 (CB): Combiner :. Conduit(D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Label . . Inverter -. DC Disconnect MAXIMUM AC A Load OPERATING CURRENT Per AC . OPERATING VOLTAGE _ V I _ Point ofInterconnection / 1 1' Ic, 1 11 1 1 1- .SIC •11• unlnm�m nr .onu r .urm 1 1' 1 1 7• 1 `1 1' 1 Label IIIIIN•OIIIIIIIIIIIIJ nminlnuuulnP.nm N 1 •1 1 •1 ' , � 11111'i1117. 11 111111'1111111'll.���111111i111111111!1 SolarCity SleekMountTM - Comp SolarCity SleekMountT"" - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM modules r aesthetics while minimizing roof disruption and Q Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and •Interlock and grounding devices in system UL t listed to UL 2703 Fastener Size Per NDS Section 1.1.3.2 mounting clamps, combined with the addition / 2 Sealilot hole with roofing sealant of array trim and a lower profile all contribute •Interlock and Ground Zep ETL listed to UL 1703 P g to a more visually appealing system.SleekMount as"Grounding and Bonding System" O3 Insert Comp Mount flashing under upper utilizes ZepCompatible modules with � � P •Ground Zep UL and ETL listed to UL 467 as � layer of shingle strengthened frames that attach directly to grounding device ® Place Comp Mount centered Zep Solar standoffs,effectively eliminating the need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition .Anodized components for corrosion resistance O5 Install lag pursuant to NDS Section 11.1.3 shingles are not required to be cut for this with sealing washer. system,allowing for minimal roof disturbance. •Applicable for vent spanning functions © Secure Leveling Foot to the Comp Mourit using machine Screw O7 Place module ® Components 0 ® 5/16"Machine Screw B ® Leveling Foot © Lag Screw OD Comp Mount _ © Comp Mount Flashing ® �t r I � SolarCity. January. 2013 Fro/m� U< LISTED ����SolarCity® January 2013 44 w`e�Ed�eesg� ��0i CS6P-235/240/245/250/255PX ``� F`am _r CanadianSolar Black-framed gteaKrn<° Electrical Data STC CS6P-235P CS6P-240P CS6P-245P CS6P-250PXCS6P-255PX Temperature Characteristics Nominal Maximum Power(Pmax) 235W 240W 245W 250W 255W _ _ Optimum Operating Voltage(Vmp) 29.8V 29.9V 30.OV 30.1V 30.2V Pmax -0.43%rC Optimum Operating Current(Imp) 7.90A 8.03A 8.17A 8.30A 8.43A Temperature Coefficient Voc -0.34%/°C Open Circuit Voltage(Voc) 36.9V 37.OV 37.1V 37.2V 37AV Isc 0.065%/'C Short Circuit Current(Isc) 8.46A 8.59A 8.74A 8.87A 9.00A Normal Operating Cell Temperature 45±2-C Black-framed • Module Efficiency 14.61% 14.92% 15.23% 1 15.54% 15.85% Operating Temperature 40'C-+85•C Performance at Low Irradiance Maximum System Voltage 1000V IEC /600V UL Industry leading performance at low irradiation Maximum Series Fuse Rating 15A environment,+95.5%module efficiency from an Application Classification Class A irradiance of t 000w/m'to 200w/m' Power Tolerance 0-+5W (AM 1.5,25°C) Next Generation Solar Module Under Standard Test Conditions(STC)ofirradiance of 1000W/m',spectrum AM 1.5 and cell temperature of25C NewEdge,the next generation module designed for multiple Engineering Drawings NOCT CS6P-235P CS6P-240P CS6P-245PXCS6P-250PXCS6P•255PX types of mounting systems,offers customers the added Nominal Maximum Power(Pmax) 170W 174W 178W 181W 185W value of minimal system costs,aesthetic seamless Optimum Operating Voltage(Vmp) 27.2y 27.3V 27.4y 27.5V 27.5y appearance,auto groundingand theft resistance. Optimum Operating Current(Imp) 6.27A 6.38A 6.49A 6.60A 6.71A Open Circuit Voltage(Voc) 33.9V 34.OV 34.1V 34.2V 34.4V The black-framed CS6P-PX is a robust 60 cell solar module Short Circuit Current(Isc) 6.86A 6.96A 7.08A 7.19A 7.29A incorporating the groundbreaking Zep compatible frame. Under Normal Operating Cell Temperature,Irradiance of 800 W/m',spectrum AM 1.5,ambient temperature 20'C, The specially designed frame allows for rail-free fast wind speed 1 m/s installation with the industry's most reliable grounding Mechanical Data system.The module uses high efficiency poly-crystalline Cell Type Poly-crystalline 156 x 156mm,2 or 3 Busbars Key Features silicon cells laminated with a white back sheet and framed Cell Arrangement 60(6 x 10) with black anodized aluminum.The black-framed CS6P-PX Dimensions 1638 x 982 x 40mm(64.5 x 38.7 x 1.57in) • Quick and easy to install - dramatically is the perfect choice for customers who are looking for a high Weight 20.5kg(45.2 lbs) reduces installation time quality aesthetic module with lowest system cost. Front Cover 3.2mm Tempered glass Frame Material Anodized aluminium alloy • Lower system costs - can cut rooftopJ-Box IP65,3 diodes installation costs in half Best Quality • 235 quality control points in module production Cable 4mm'(IEC)/12AWG(UL),1000mm 912 Connectors MC4 or MC4 Comparable • Aesthetic seamless appearance - low profile EL screening to eliminate product defects cs Standard Packaging(Modules per Pallet) 2a with auto leveling and alignment • Current binning to improve system performance p • Accredited Salt mist resistant Module Pieces per container(40 ft.Container) 672pcs(40'HQ) --- • Built-in hyper-bonded grounding system - if it's I-V Curves(CS6P-255PX) mounted,it's grounded Best Warranty Insurance • Theft resistant hardware • 25 years worldwide coverage o + Section A-A i • 100/o warranty term coverage • Ultra-low parts count - 3 parts for the mounting • Providing third party bankruptcy rights 35.0 and grounding system • Non-cancellable ` • Immediate coverage • " ' Industry first comprehensive warranty insurance by 3 , . AM Best rated leading insurance companies in the • Insured by 3 world top insurance companies 4 world Comprehensive Certificates • Industry leading plus only power tolerance:0-+5W IEC 61215,IEC 61730, IEC61701 ED2,UL1703, • Backward compatibility with all standard rooftop and CEC Listed,CE and MCS ground mounting systems • IS09001:2008:Quality Management System •" . ISO/TS 16949:2009:The automotive quality Specations included in this datasheet are subject to change without prior notice. • Backed By Our New 10/25 Linear Power Warranty management system Plus our added 25 year insurance coverage • IS014001:2004:Standards for Environmental About Canadian Solar management system Canadian Solar Inc. is one of the world's largest solar Canadian Solar was founded in Canada in 2001 and was 70g�% q • QC080000 HSPM:The Certification for companies. As a leading vertically-integrated successfully listed on NASDAQ Exchange (symbol: CSIQ) in dded Value Fro Hazardous Substances Regulations manufacturer of ingots,wafers,cells,solar modules and November 2006. Canadian Solar has module manufacturing 90% m Warranty solar systems, Canadian Solar delivers solar power capacity of 2.05GW and cell manufacturing capacity of 1.3GW. - OHSAS 18001:2007 International standards for products of uncompromising quality to worldwide 80% occupational health and safety customers. Canadian Solar's world class team of 0% s 10 1s 20 2s REACH Compliance professionals works closely with our customers to provide them with solutions for all their solar needs. Headquarters 1545 Speedvale Avenue West • 1E6 I Canada •10 year product warranty on materials and workmanship : a� '�`. $p• .•-- ?`ea Q cast E c' G�� .. . r :: •25 year linear power output warranty r www.canadiansolar.com EN-Rev 10.17 Copyright O 2012 Canadian Solar Inc. solar=ee T solar=se T SolarEdge Power Optimizer Module Add-On for North America P300 / P350 / P400 SolarEdge Power Optimizer P300 P350 P400 Module Add-On For North America (for 6G-cell PV (for 72-cell PV (fbr96-cellPV modules) modules) modules) INPUT P300 P350 P400 Rated l9put DC Power" 300 350 400 Absolute Maximum Input Voltage(Voc at lowest temperature) 48 60 80 M.P.PT.Operating Range 8.-. 8-69 8-80 Vdc ............... ............ ......Adc Maximum DC Input Curren[ . Ad . ...... Maximum Efficiency..... ....... ....... ........... % Weighted Efficiency 98.8............ ............ Overvoltage Category 11 OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) ....irnum Output Current ...... IS. ......... Adc ..... Maximum Output Voltage 60 OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER Safety Output Voltage per Power Optimizer I Vdc STANDARD COMPLIANCE I Z+,1 EMC .............. FCC Part15 Class JEC61P90-6 �3 Safety................ .... .. ....... RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions(W X.IL H) 141x212 x40.5/S.SSx8.34x159 mm/in Weight(including cables) _ ......95012A......................... gr/Ib ....... ..'nIput Connector MC4/Amph"ol/Tyco Pytp'lt Wire Type/Connector Double Insulated;Ampherol Oytpu�WirpLenglh 12/3.9 0 ol..... _........ ........ Operating Temperature Range -40-+85 -40-+185 'C/F ............ .......... ........ Protection Rating IP65/NEMA4 Relative Humidity 0-100 % . ....... .... ...... ........ '-d f--dm,.Mtor pp t.S%p— A�d. PV SYSTEM DESIGN USING A SOLAREDGE SINGLE PHASE THREE PHASE THREE PHASE INVERTER 208V 480V PV power optimization at the module-level Minimum..Stri.n.g Leng,th.(.Power Opt.iTi.zem) 8.......... to1.8 . .f.Diff.ere.ntLe.n.g.t.h.s.o.r.O.rie.n.t.a.tio,ns, ...... .Yes — Up to 25%more energy Maximum,String Length(Power Optimizers) 25 25 Maximum Power per String 5250 6000 12750 W - Superior efficiency(99.5%) ... — Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading .......Parallel Strings. — Flexible system design for maximum space utilization — Fast installation with a single bolt — Next generation maintenance with module-level monitoring — Module-level voltage shutdown for installer and firefighter safety USA - GERMANY - ITALY - FRANCE - JAPAN CHINA - ISRAEL AUSTRALIA www.solaredge.us 4c s t solar a r=eeSingle Phase Inverters for North America soIar SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ SE760OA-US/SE10000A-US/SE1140OA-US SE3000A-US SE380OA-US SE5000A-US SE6000A-US I SE760OA-US SE10000A-US I SE1140OA-US OUTPUT S o l a r E d g e Single Phase I n ve rte rs Nominal AC Power Output 3000 3800 5000 6000 7600 9980 @ 208V . ......11400 VA ............ 10000.@240V ..................................... . ..... ................ .. ........ ....... .... ....... .... For North America 5400@208V 10950@20BV Max.AC Power Output 3300 4150 6000 8350 12000 VA 5450 @240V 10950 @240V AC Output Voltage Min.-Nom.-Max.- SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ 183-208-229 Vac ...................... .. .. . . ........ ............... ................. ................ ................ .................. .................. ........... AC Output Voltage Min.-Nom:.Ma.x.*.. ......�. � � � � SE7600A-US/SE1000DA-US/SE1140OA-US ..211-.240-..264 Vac ..... .... ............................. ................ ............... ................. ................ ................ .................. .................. ........... AC Frequency Min.-Nom;Max;* 59,3:50:60.5(with HI country setting 57-.60.-60:5) Hz 24 @ 208V 48 @ 208V j Max.Continuous Output Current - 12 5 I - 16 21 @ 240V ,,... 25 32 42 @ 240V.._ 47.5 A E .......... ............... .. ... .. .... i ...... ........ I ` .......G1 A FDI.........................I.......... ............................................................... ........................................................... ...... .... Utility Monitoring,Islanding Protection,Country Configurable Yes Thresholds w122 INPUT m` Recommended Max.DC Power`* VearntY »' 3750 4750 6250 7500 9500 12400 14250 W y m (STC .g Wan ............................. . ..... ................. ................ ................ .................. ................ Transformer-less,Ungrounded Yes ......................... .............. .......................................................................................................................... ........... -r^••,•,.:..� - Max.InputVoltage 500 Vdc ........................................... .......................................................................................................................... ........ Nom.DC Input Voltage 325 @ 208V/350 @ 240V Vdc I - - '16.5@208V . 33@208V Max.Input Current— 9.5 13 18 23 34.5 Adc 240V 30.5 @ 240V .............. ...... ............. .. .. ......... ..... ...... . ........ ........ ..... .... ......... ....... .............. .... ... Max.Input Short Circuit Current 30 45 ........................................... .................. ............... .................................................... ... Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600ka Sensitivity MaximuminverterEfficiency..___.__ ....97.7...- ...98.2.._ 98.3 98.3 .98.... ......98.... .....98...... ..%..... .. .. .. .. .. .. .. .. .. .. . ........ ........... ........ .. .. 97.5 @ 208V 97 @ 208V -- CEC Weighted Efficiency ....97.5...... ......98......I..98.@.240V..I......97.5..... ......97.5...... ..975_@.240V.. ......97.5....... ..../..... ........................................... . Nighttime Power Consumption <2.5 <4 W ADDITIONAL FEATURES I Supported.Co.m..munication Interfaces. ...................... RS485,RS232,Ethernet,ZigBee(optional) ..k �,,..:.. ............. .. . ..... ..... ........ .. ...... ................... ................ ... ..................................... . Revenue Grade Data,ANSI C12.1 Optional STANDARD COMPLIANCE - - Safety ...................................... .................... Grid Connection StandardsIEEE1547 _Em.issions FCC part15 class B INSTALLATION SPECIFICATIONS AC output conduit size/AWG range 3/4".m i n i m.u.m/24 6 AWG 3/4"minimum/.8.-.3 AWG DC input conduit size If of strings/ AWG range3/4"minimum/1-2 strings/24-6 AWG 3/4"minimum/1-2 strings/14-6 AWG ...................................I....... ................................ .................................. ............................................. ........... Dimensions with AC/DC Safety 30.5 x 12.5 x 7/ 30.5 x 12.5 x 7.5/ in/ 30.Sx12.5x10.5/775x315x260 �1. Switch(HxWxD)........................ ........775x315x172...-.... ......_.775x315x19........___ ..mm _Weight with AC/DC Safety Switch .,,,......51.2/23.2 ..,,-.,...54.7/24.7 ....................88.4/40.1 lb/.kg... ........................I........ ............... . ................ . ............................ . Cooling Natural Convection Fans(user replaceable) .... . . . ..... .......................... . ................................. . ................................ ...... ... The best choice for SolarEd a enabled systems Noise <zs <so d.. .. ........................................ ................................................................... ...................................................... ........... g y Min.-Max.Operating Temperature - Integrated arc fault protection(Type 1)for NEC 2011690.11 compliance Range ,. -13 to+la0/-zs to+60(CAN version"`*40to+6o) 'F/'C ........................................................................ .. Superior efficiency(98%) Protection Rating NEMA 3R . ................................................................................................................... ........... Protection other regional settings please contact SoNrEdge Suppor.. — Small,lightweight and easy to install on provided bracket Dmitedto 125%for locations where the yearly average high temperature is above 77'F/25'C and to 135%for locations where itlsbelow77'F/25'C. For detailed information,refer to htto//www solaredge us/files/odfs/inverter do oversizing au11,ndf — Built-in module-level monitoring �.•A higher current source maybe used;the inverter will limit its input current[o the values state d. '"CAN P/Ns are eligible for the Ontario FIT and micro FIT(microFIT exc.SE31400A-US-CAN). — Internet connection through Ethernet or Wireless — Outdoor and indoor installation — Fixed voltage inverter,DC/AC conversion only — Pre-assembled AC/DC Safety Switch for faster installation — Optional—revenue grade data,ANSI C12.1 ON suns?gc Ro H S USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-ISRAEL www.solaredge.us ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. 1 CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING P01 POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 THREE LINE DIAGRAM LICENSE GENERAL NOTES Cutsheets Attached GEN #168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION ELEC 1136 MR OF THE MA STATE BUILDING CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: ZEP SOLAR AHJ: North Andover REV BY DATE COMMENTS REV A NAME DATE COMMENTS UTILITY: National Grid USA (Massachusetts Electric) CONnDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-01 81270 00 PREMISE ONNER. DESCRIPTION: DESIGN: SARRO, NANCY SARRO RESIDENCE \N���SolarGty. CONTAINED SHALL NOT BE USED FOR THE Rob Solaski �" BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �a8 NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 44 EQUESTRIAN DR 10.71 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES. NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St. Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (42) CANADIAN SOLAR # CS6P-255PX Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET, REV: DATE PERMISSION of SOLARCITY INC. '"`�'� 6174353524 PV 1 10/31/2014 (888T)—SOL—CITY(765-2489) www�..solaarciycom Multiple Inverters COVER SHEET PITCH: 30 ARRAY PITCH:30 MPI AZIMUTH: 141 ARRAY AZIMUTH: 141 PITCH: 30 ARRAY PITCH:30 MP2 AZIMUTH: 141 ARRAY AZIMUTH: 141 MATERIAL: Comp Shingle STORY: 1 Story PITCH: 15 ARRAY PITCH:15 MP3 AZIMUTH: 141 ARRAY AZIMUTH: 141 G 40 co m MATERIAL: Comp Shingle STORY: 1 Story B PITCH: 30 ARRAY PITCH:30 CD DRIVEWAY MP4 AZIMUTH:231 ARRAY AZIMUTH:231 o 1 MATERIAL: Comp Shingle STORY: 1 Story a a zdt -%H OF LEGEND Y00 JAN K VA H Q (E) UTILITY METER & WARNING LABEL NO.41 INVERTERW/ INTEGRATED DC DISCO a Ing & WARNING LABELS AL Z! © DC DISCONNECT & WARNING LABELS Wl!d Digitally gne y Yoo Jin Kim ° Date:20 4.10.31 13:55:52 © AC DISCONNECT & WARNING LABELS -07'00' Front Of House O DC JUNCTION/COMBINER BOX & LABELS DISTRIBUTION PANEL & LABELS z c PI; MP4 d Lc LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER A Q STANDOFF LOCATIONS — CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR D %' _�' — GATE/FENCE Q HEAT PRODUCING VENTS ARE RED �' O Inv Inv _- '% ''' INTERIOR EQUIPMENT IS DASHED LC L,:._ © J SITE PLAN Scale: 3/32" = 1' 01' 10' 21' CONFlDENIIAL— THE INFORMATION HEREIN JOB NUMBER: JB-01 81270 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE SARRO, NANCY SARRO RESIDENCE Rob Solaski = ;; BENEFIT OF ANYONESo�arCity. EXCEPT SOLARCITY INC., MOUNTING SYSTEM: .,; NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 44 EQUESTRIAN DR 10.71 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St. Matin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (42) CANADIAN SOLAR # CS6P-255PX �, SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN C Z PAGE NAME SHEET: REV: DATE Morlborou MA 01752 PERMISSION OF SOLARCITY INC. INVERTER. V1 743rjJrj24 PV 2 10/31/2014 L (650)638-1028 F: (650)638-1029 Multiple Inverters SITE PLAN (888)—SOL—CITY(765-2489) •ww.solarcity.eom �tH GF� Y00 JIN S 1 S 1 KVI y No.4 4" � 13'-8" 14'-10" to 1'— (E) LBW Digital y Yoo Jin Kim 1 — (E) LBW A SIDE VIEW OF MP1 NTS a 0: 014.10.31 13:55:45 B SIDE VIEW OF MP2 NTs MPI X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER I NOTES MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 64" 24" STAGGERED LANDSCAPE 64" 24" STAGGERED PORTRAIT 1 48" 20" 1 PORTRAIT 48" 20" RAFTER 2X8 @ 16"OC ROOF AZI 141 PITCH 30 STORIES2 ROOF AZI 141 PITCH 30 ARRAY AZI 141 PITCH 30 : RAFTER 2x8 @ 16"OC ARRAY AZI 141 PITCH 30 STORIES: 1 C.I. 2x8 @16"OC Comp Shingle C.I. 2X8 @16"OC Comp Shingle PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. ZEP COMP MOUNT C ZEP FLASHING C (3) ti (3) INSERT FLASHING. (E) COMP. SHINGLE (4) PLACE MOUNT. (1) (E) ROOF DECKING (2) INSTALL LAG BOLT WITH 5/16" DIA STAINLESS (5) (5) SEALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULESINSTALL LEVELING FOOT WITH WITH SEALING WASHER (6) BOLT & WASHERS. (2-1/2" EMBED, MIN) (E) RAFTER STANDOFF CONFIDENTIAL— THE INFORMATION HEREIN FER JB-01 81270 00 PREMISE OWNER: DESCRIPTION: DESIGN: SARRO, NANCY SARRO RESIDENCE ��,,,So�arCity. CONTAINED SHALL NOT BE USED FOR THE Rob Solaski BENEFIT OF ANYONE EXCEPT SOLARGTY INC.. MOUNTINGTEM �.��� NOR MALL IT BE DISCLOSED IN WHOLE OR INount Type C 44 EQUESTRIAN DR 10.71 KW PV ARRAY PART IZ OTHERS OUTSIDE THE RECIPIENTS NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St.Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE NADIAN SOLAR # CS6P-255PX Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REN DATE T: (650)638-1028 F: (650)636-1029 PERMISSION OF SOLARGTY INC. Inverters 6174353524 STRUCTURAL VIEWS PV 3 10/31/2014 (888)—Soi.—CITY(765-2489) rn.rr.solaraltyaom GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE ber:IIE Inv 1: DC Ungrounded GE s000A-us000SNR �pgEL p � � -(42)CANADIAN SOLAR CS6P-255PX # ODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:05062224 Inv 2: ngroun e n er ; hn,a IiII �Ertt>-1 , GEN 168572 ivivuumtG_1-136-MRs Underground Service Entrance. Tie-In: Supply Side Connection INV 2 -(1)SOLAREDGE !SE3000A-US000SN 2 B Inverter, 30 W, 24OV, 97.5% w�Unifed D'Isco and ZB,RGM,AFCI Voc: 37,4 VpmOX: 30.2 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL E 20OA/2P MAIN CIRCUIT BREAKER SolarCity (E) WIRING CUTLER-HAMMER BRYANT Inverter 1 Disconnect CUTLER-HAMMER 125A Load Center120OA/2P 10 Disco711 7 SOLAREDGE Dc+ - B 50A D SE6000A-US000SNR2 DC- MP 1: 1x14 C 35A/2P EGc z4ov ------------ - ------- - --------------------4 A L1 F---------- g L2 DC+ I I N ne I 4 2 I (E) LOADS GND _ ECIC_/ DC+ DO, ---- GND - -� r r-------------- - GEC ---� N Dc Oc- MP 1: 1x13 GND -- E --- --------- ------------ - - ----- - EGC------------------ � .J II Inverter 2 (1)Conduit Kit; 3/4' EMT �EGaGGEC II 8 SOLAREDGE I I i SE3000A-USOOOSNR2 20A/2P L1 z75v L2 I TO 120/240V I I I N 6 3 I SINGLE PHASE I I L_ EGC! Dc. DC+ UTIUTY SERVICE I I ____-_____------ -GEC ---SIN Da 11 1 1 DC- MP 1&2: 1x15 I EGC- -------------------------- - -'----- - EGC-----------------♦ I I i I I I I PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Voc* = MAX VOC AT MIN TEMP p�I (2)Ground Rod; 5/8' x 8', Copper B (1)CUTLER-HAMMER #DG222NRB A (1)SolarCit 4 STRING JUNCTION BOX -(2)ILSCO/IPC 4/0-/6 Disconnect; 60A, 24OVac,Fusible, NEMA 3R AC 2x2 S1YR GS, UNFUSED, GROUNDED DC Insulattion Piercing Connector; Main 4/0-4, Tap 6-14 -0)CUTLER- AMMER ��II DG100NB D (I)BGround�Neutral It; 60-100A General Duty(DG) PV (42)SOLAREDGE 300-2NA4AZS /RYANT BR816Lj125RP -(1)CUTLER-HAMMER DS16FK PowerBox ptimizer, 300W, H4, DC to DC, ZEP Load Center, 125A, 120/24OV, NEMA 3R Class R Fuse Kit -(1)CUTLER-HAMMEJ2/BR235 -(2)FERRAZ SHAWMUT#TR50R PV BACKFEED OCP n d (1)AWG X16, Solid Bare Copper Breaker, 35A 2P, 2 Spaces Fuse; 50A, 25OV, Class RK5 -(1)Ground Rod; 5/8' x 8', Copper -(1)CUTLER-HAMM BR220 Breaker, 20A/2i9 P, 2 Spaces C (1)CUTLER-HAMMER #DG222URB N ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION N0. 2, ADDITIONAL SUPPLY SIDE CONNECTION. DISCONNECTING MEANS SHALL BE SUITABLE Disconnect; 60A, 24OVoc, Non-Fusible, NEMA 3R ( ) SC AS SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. -(1)Gra d�NeuME KitD 00-OOA General Duty(DG) ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE 1 AWG/8, THWN-2, Black 1 AWG#8, THWN-2, Black (1)AWG#10, THWN-2, Black Voc* =500 VDC Isc =15 ADC 2)AWG 110, PV WIRE, Block Voc* =500 VDC Isc =15 ADC O (1)AWG 18, THWN-2,Red O (1)AWG,y8, THWN-2, Red ® (1)AWG/10, THWN-2, Red Vmp =350 VDC Imp=9.35 ADC O (1)AWG N6 Copper P Imp= (1)AWG/8, THWN-2,White NEUTRAL Vmp =240 VAC Imp=37.5 AAC (I)AWG 0, THWN-2, White NEUTRAL Vm =240 VAC IMP=25 AAC Solid Bare Co er EGC Vmp =350 VDC Im 10.07 ADC 41 P P- 1)AWG/10. THWN-2..Green. . EGC. . . . . . I . . . . . . . . . . . . .. . . . . . . . . . . . '70)AN/8,.THWN-?,.Green . . EGC/GEC.-(1)Conduit.Kit;.3/4'.EMT. . .. . . . . . . .. . . . . .-(1)AWG#8,.THWN-2,.Green . . EGC/GEC.-(1)Conduit.Kit;,3/4",EMT. . . . . . .. . . (1)AWG 110, THWN-2, Black Voc* =500 VDC Isc =15 ADC (?)AWG X110, PV WIRE, Black Voc* =500 VDC Isc =15 ADC (1)AWG/B, THWN-2,Black (1)AWG#10, THWN-2, Black O (1)AWG 110, THWN-2, Red Vmp =350 VDC Imp=10.07 ADC O (1)AWG 16, Solid Bare Copper EGC Vmp =350 VDC IMP=9.35 ADC ® (1)AWG/6, THWN-2,Red go (1)AWG g10, THWN-2, Red (1)AWG#10, THWN-2,,Green, EGC. . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . ISL. . .. . . . . . . (i)AWG/6, THWN-2, Mite NEUTRAL Vmp =240 VAC Imp=37.5 AAC (1)AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC IMP AAC (1)AWG/10, THWN-2, Black Voc* =500 VDC Isc =15 ADC (2 AWG /10, PV WIRE, Black Voc* =500 VDC Isc =15 ADC . . . ._ . .7(1)AWG#6,.Solid Bare.Copper. GEC. . . .-(1)Conduit.Kit;.3/4'.EMT. . .. . . . . . . .. . . . . .7(1)AWG#8,.THWN72,,Green . . EPC/GEC.-(1)Conduit.Kit;,3/4'_ . . . . . . . . . . © g (1)AWG 110, THWN-2, Red Vmp =350 VDC IMP=10.79 ADC O (1)AWG /6, Solid Bare Copper EGC Vmp =350 VDC Imp=10.79 ADC .. . . . . . (1)AWG /10, TIiWN-2,.Green. . EGC. . . .-(1)Conduit.Kit;.3/4'.EMT. , , . . . . , , . . . . . . . . . .. . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER PREMISE 090: DESCRIPTION: DESIGN JB-0181270 00 \\, SolarCit . CONTAINED SHALL NOT BE USED FOR THE SARRO, NANCY SARRO RESIDENCE Rob Solaski � , • " BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: .,; y NOR SHALL IT BE DISCLOSED IN WHOLE OR N Com Mount Type C 44 EQUESTRIAN DR 10.71 KW PV ARRAY �� PART TO OTHERS OUTSIDE THE RECIPIENT'S IMODULES: NORTH ANDOVER MA 01845ORGANIZATION, EXCEPT IN CONNECTION WITH , 24 St.Martin Drive,Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (42) CANADIAN SOLAR # CS6P-255PX t' SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE: Malborough, MA 01752 PERMISSION OF SOLARCITY INC. IMUItR le Inverters 6174353524 THREE LINE DIAGRAM PV 4 10/31/2014 (888)-SOL-CITY)6765-2489j6�soarcit�am Label Location: Label Location: Label Location: WARNING:PHOTOVOLTAIC:111TA A"W0111ONZ1111 Per - Code: WARNING Code:' WARNING ' Code: NEC 690.31.G.3 ELECTRIC SHOCK HAZARNEC D •. ELECTRIC SHOCK HAZARD NEC •. DO NOT TOUCH TERMINALS THE DC CONDUCTORS OF THIS Label Location: TERMINALS ON BOTH LINE AND PHOTOVOLTAIC SYSTEM ARETO BE USED WHEN LOAD SIDES MAYBE ENERGIZED UNGROUNDED AND • Per PHOTOVOLTAIC DC ! Code: •- IN THE OPEN POSITION - MAY BE ENERGIZED UNGROUNDED NEC DISCONNECT .•0 bwLabelrLabel Location: WARNING Code: MAXIMUM POWER- POINT CURRENT(Imp)_A Per CodeINVERTER OUTPUT 690.64.13.7 MAXIMUM POWER- CONNECTION POINT VOLTAGE(Vmp)_VNEC 690.53DO NOT RELOCATE THIS OVERCURRENT MAXIMUM SYSTEM V DEVICE VOLTAGE{Voc)_ SHORT-CIRCUIT - - ' CURRENT(Isc)_A Label • • PHOTOVOLTAIC POINT OF '• Label • • INTERCONNECTION Per ••- WARNING: ELECTRIC SHOCK WARN LN G HAZARD.DO NOT TOUCH NEC . 690.54 Per Code: TERMINALS.TERMINALS ON ELECTRICAL SHOCK HAZARD BOTH THE LINE AND LOAD SIDE DO NOT TOUCH TERMINALS 690.17(4) MAY BE ENERGIZED IN THE OPEN TERMINALS ON BOTH LINE AND POSITION.FOR SERVICE LOAD SIDES MAY BE ENERGIZED DE-ENERGIZE BOTH SOURCE IN THE OPENpOSITION AND MAIN BREAKER. DC VOLTAGE IS PV POWER SOURCE ALWAYS PRESENT WHEN MAXIMUM AC SOLAR MODULES ARE OPERATING CURRENT A EXPOSED TO SUNLIGHT MAXIMUM AC OPERATING VOLTAGE - V Label • • WARNINGLocation: Per ELECTRIC SHOCK HAZARD 690.5(C) CAUTION (PO Code: IF AGROUND FAULT IS INDICATEDPHOTOVOLTAIC SYSTEM NORMALLY GROUNDED CIRCUIT IS BACKFED 690.64.13.4 CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED Label • • Label PHOTOVOLTAIC AC '• Du C ow BION cE Per•Code: Disconnect DISCONNECTPer Code: PHO OVOLTAOICSYSTEM 690.64.B.4 (C): Cond ,' •, • I • uit NEC •.014.C.2 (CB): Combiner :. Distribution Conduit(DC): DC Disconnect (IC): Interior Run Label AC A Load OPERATING CURRENT Per Code: Meter(M): Utility MAXIMUM AC VNEC . Pointof • • OPERATING VOLTAGE oil • • • • • • • i n■ •uuu• nn•n• • • • • • • • SIC Label unmuiunimnr••owwcu•wnrm■ • • � • ' I nnum:• a wwunm•iuuunmuwuni• SolarCity SleekMountTM - Comp SolarCity SleekMountT"" - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM modules r aesthetics while minimizing roof disruption and 0 Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and •Interlock and grounding devices in system UL Fastener Size Per NDS Section 1.1.3.2 listed to UL 2703 mounting clamps, combined with the addition of array trim and a lower profile all contribute •Interlock and Ground Zep ETL listed to UL 1703 �� 0 Seal pilot hole with roofing sealant as"Grounding and Bonding System" 3 Insert Com Mount flashing under upper to a more visually appealing system.SleekMount \ 0 P 9 PP utilizes Zep Compatible TM modules with •Ground Zep UL and ETL listed to UL 467 as layer of shingle strengthened frames that attach directly to grounding device ® Place Comp Mount centered Zep Solar standoffs,effectively eliminating the need for rail and reducing the number of •Painted galvanized waterproof flashing ` upon flashing standoffs required. In addition, composition \ O5 Install lag pursuant to NDS Section 11.1.3 •Anodized components for corrosion resistance \\ shingles are not required to be cut for this \ with sealing washer. system,allowing for minimal roof disturbance. •Applicable for vent spanning functions © Secure Leveling Foot to the Comp Mount using machine Screw O7 Place module ® Components _ I © ® 5/16"Machine Screw © Leveling Foot © Lag Screw ® Comp Mount j © © Comp Mount Flashing 00 0 O r SolarCity / 0% LISTED SolarCity. ® January 2013 ��o P►°m ® January 2013 r �tidges�g^ ,.IiCS6P-235/240/245/250/255PX ID" NeF`am Nr CanadanSolar Electrical Data Black-framed eteak`�< - STC CS6P-235P CS6P-240P CS6P-245P CS6P-250PXCS6P-255PX Temperature Characteristics Nominal Maximum Power(Pmax) 235W 240W 245W 25OW 255W Optimum Operating Voltage(Vmp) 29.8V 29.9V 30.0V 30.1V 30.2V Pmax -0.43 rc NewEdge Optimum Operating Current(Imp) 7.90A 8.03A 8.17A 8.30A 8.43A Temperature Coefficient Voc -0.34%/°C Open Circuit Voltage(voc) 36.9V 37.OV 37.1V 37.2V 37AV Isc 0.065%/°C Black-framed Short Circuit Current(Isc) 8.46A 8.59A 8.74A 8.87A 9.00A Normal Operating Cell Temperature 45±2°C • • • Module Efficiency 14.61% 14.92% 15.23% 15.54% 15.85 Operating Temperature _40°C-+85°C Performance at Low Irradiance Maximum System Voltage 1000V(IEC)/600v UL Industry leading performance at low irradiation Maximum Series Fuse Rating 15A environment,+95.5%module efficiency from an Application Classification ClassA irradiance of 1000w/m'to 200w/m' Next Generation Solar Module Power Tolerance 0_+5W (AM 1.5,25-C) Under Standard Test Conditions(STC)of irradiance of 1000W/m',spectrum AM 1.5 and cell temperature of 25'C NewEdge,the next generation module designed for multiple Engineering Drawings N OCT CS6P-235PX CS6P-240PX CS6P-245PX CS6P-250PX CS6P-255PX types of mounting systems,offers customers the added Nominal Maximum Power(Pmax) 170W 174W 178W 181w 185W value of minimal system costs,aesthetic seamless _Optimum Operating Voltage(Vmp) 27.2V 27.3V 27AV 27.5V 27.5V appearance,auto groundingand theft resistance. Optimum Operating Current(Imp) 6.27A 6.38A 6.49A 6.60A 6.71A Open Circuit Voltage(Voc) 33.9V 34.OV 34.1V 34.2V 34AV The black-framed CS6P-PX is a robust 60 cell solar module Short circuit Current(Ise) 6.86A 6.96A 7.08A 7.19A 7.29A incorporating the groundbreaking Zep compatible frame. Under Normal Operating Cell Temperature,Irradianca of 800 W/m',spectrum AM 1.5,ambient temperature 20'C, The specially designed frame allows for rail-free fast wind speed 1 m/s installation with the industry's most reliable grounding Mechanical Data system.The module uses high efficiency poly-crystalline Cell Type Poly-crystalline 156 x 156mm,2 or 3 Busbars Key Features silicon cells laminated with a white back sheet and framed Cell Arrangement 60(6x 10) with black anodized aluminum.The black-framed CS6P-PX Dimensions 1638 x 982 x 40mm(64.5 x 38.7 x 1.57in) • Quick and easy to install - dramatically is the perfect choice for customers who are looking for a high Weight 20.5kg(45.2 lbs) reduces installation time quality aesthetic module with lowest system cost. Front cover 3.2mm Tempered glass Frame Material Anodized aluminium alloy • Lower system costs - can cut rooftopJ-BOX IP65,3 diodes Best Quality I s2 installation costs in half Cable 4mm'(IEC)/12AWG(UL),1000mm yi • 235 quality control points in module production Connectors MC4 or MC4 Comparable • Aesthetic seamless appearance - low profile • EL screening to eliminate product defects with auto leveling and alignment • Current binning to improve system performance Standard Packaging(Modules per Pallet) 24pcs • Accredited Salt mist resistant Module Pieces per container(40 ft.Container) 672pcs(40'HQ) - • Built-in hyper-bonded grounding system - if it's I-V Curves(CS6P-255PX) mounted,it's grounded Best Warranty Insurance a . • Theft resistant hardware • 25 years worldwide coverage 9 , o e Section A-A • 100/o warranty term coverage • Ultra-low parts count - 3 parts for the mounting • Providing third party bankruptcy rights 35.0 and grounding system • Non-cancellable • Immediate coverage Industry first comprehensive warranty insurance by _ , a AM Best rated leading insurance companies in the • Insured by 3 world top insurance companies I 0 1 e v world Comprehensive Certificates i -6 -'� • Industry leading plus only power tolerance:05W • IEC 61215,IEC 61730, IEC61701 ED2,UL1703, <e • Backward compatibility with all standard rooftop and CEC Listed,CE and MCS s ground mounting systems IS09001:2008:Quality Management System • ISO/TS16949:2009:The automotive quality •Specifications included in this datasheet are subject to change without prior notice. • Backed By Our New 10/25 Linear Power Warranty management system Plus our added 25 year insurance coverage • IS014001:2004:Standards for Environmental About Canadian Solar management system Canadian Solar Inc. is one of the world's largest solar Canadian Solar was founded in Canada in 2001 and was 197% q • QC080000 HSPM:The Certification for companies. As a leading vertically-integrated successfully listed on NASDAQ Exchange (symbol: CSIQ) in Added Value Fro Hazardous Substances Regulations manufacturer of ingots,wafers,cells,solar modules and November 2006. Canadian Solar has module manufacturing 90% rn Warranty solar systems, Canadian Solar delivers solar power capacity of 2.05GW and cell manufacturing capacity of 1.3GW. • OHSAS 18001:2007 International standards for products of uncompromising quality to worldwide 80% occupational health and safety customers. Canadian Solar's world class team of o% s 10 1s zo zs REACH Compliance professionals works closely with our customers to provide them with solutions for all their solar needs. Headquarters Ontario -10 year product warranty on materials and workmanship • i Tel:-1 519 837 1881 25 year linear power output warranty O $4.0`ra ` E Fax:+1 519 837 2550 www.canadiansolar.com EWRe,10.17 Copyright 0 2012 Canadian Solar Inc. • solar ' 90 T solar ' @@ Sol arEdge Power Optimizer Module Add-On for North America P300 P350 / P400 SolarEdge Power Optimizer P300 P350 I P400 Module Add-On For North America (for 60-cell PV (for 72-cell PV (for 96-cell PV modules) modules) modules) • INPUT P300 P350 P400 Rated Input DC Power") 3.00....... ...356------- 400 W Absolute Maximum Input Voltage(Voc at lowest temperature) 0 C ............................ .................................. MPPTOp,!atin Range 8-48 B-80 F_ .......... ............... -............... Vdc.._. • Maximum Short Circuit CUrrent(Isc)_........ ........... ................................1.0 Adc ..Maximum DC Input Current.. ..... .5 Adt ..Maximum Efficiency 99:5 % Weighted Efficiency 98.8 Overvoltage Category OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) Maximum Output Current ..............1.5 Acic� Maximum Output Voltage 60 Vdc • OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE .FCC Par15 Class B,I.EC61000-6-2,IEC61000-6-3 IEC62109- Safety ...........� .1,(class I I safety), 741.... ....... RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions(W x L x H) 1.4.1 x 212 x.4,0.51J.5.55 x8..3.4.x.1.59 Mm/in Weight(including cables) 950/2.1 gr/lb ..Input Connector ...MC4/ATplhen?l/Tyco Output tWire Type/Connector Double Insulated;Amphenol Output Wire Length ...095/30..._ 1Z/39.. .m./ft.. Operating,.Temperature.Range........ ...... ............. ......-- -4.0.-..,.1.85.�............... ......... C./ Protection Rating ....... ...... P�5/.NEMA.4.. ...... Relative Humidity 0 % ......................... PV SYSTEM DESIGN USING A SOLAREDGE SINGLE PHASE THREE PHASE THREE PHASE INVERTER 208V 490V PV power optimization at the module-level minimum String Length(Power Optimizers) 8 10 18 Maximum String Length(Power Optimizers) 25 50 - Up to 25%more energy Maximum Power pe I r.String I ........- 5250. 60.00 12750..... W - Superior efficiency(99.5%) Parallel Stringsof..Differ..Different Lengths or Orientations .Ye.s....... ................ - Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading ............... ........................ ...............- - Flexible system design for maximum space utilization - Fast installation with a single bolt - Next generation maintenance with module-level monitoring - Module-level voltage shutdown for installer and firefighter safety CE ON USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL AUSTRALIA www.solaredge.us IQ�ARE�E.Zh,Slll�dgli.g,.OPT:�IZEDBYSOL�E�GE solar=ee Single Phase Inverters for North America soIar SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ SE760OA-US/SE1000OA-US/SE1140OA-US SE3000A-US SE380OA-US SE5000A-US SE6000A-US SE760OA-US I SE10000A-US I SE1140OA-US OUTPUT SolarEdge Single Phase Inverters • Nominal AC Power Output 3000 3800 5000 6000 7600 9980 @ 208V10000@240V 11400 VA ........................................... ................ ............... ................. ................ ................ .................. .................. ........... For North America 5400@208V 10800@208V Max.AC Power Output 3300 4150 6000 8350 12000 VA ............... ............... .5450 @240V 10950 @240V AC Output Voltage Min.-Nom.-Max.* SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ 1s Output zz9vac . ..... ................................... ................ ............... ................. ................ ................ .................. .................. ........... AC Output Voltage Min.-Nom.-Max.* � � � SE760OA-US/SE10000A-US/SE1140OA-US 211-240-264 Vac ........................................... ................ ............... ................. ................ ................ .................. .................. ........... AC Frequency Min:Nom:Max.` 59.3-60-60.5(with HI country setting 57-60-60.5) Hz ........................ ................ ................ Max.Continuous Output Current 12.5 16 24 @ ZOSV 25 32 48 @ 208V 47.5 A 21 @ 240V... ....._......... ................ 42 @ 240V ........................................... ................ ............. ... .................. ................ . A ... I ..GFDI.. .... 1 A I . .... ................g............ ...........................................-................... ........................................................... ........... Utility Monitoring,Islanding Protection,Count Configurable Yes :+ ""Ver ej`�-.;_, Thresholds d 12-25 2= INPUT _ = Recommended Max.DC Power- 0(STC) 3754750 6250 7500 9500 12400 14250 W WaRantY; ................................ . ............. . ........ .................. ................ .. .. >,. ��.f Transformer-less: Ungrounded Yes ................... ...... ................ .......................................................................................................................... .. .... ... Max.Input Voltage 500 Vdc ..Nom.DC.Input Voltage............... ............................................325 @ 208V/350 @ 240V............................................ .Vdc.... ......... . ......... . .. .. .. .. .. ...... ... @ .... 16.5 @ 208V 33 @ 208V Max.Input Current— 9.5 13 15.5 @ 240V 18 23 30.5 240V 34.5 Adc ..............L................ ................ ................ .................. .................. . Max.In ut ShortCircuit Current 30 45 Adc -, Reverse-PpIarit Protection Yes Ground-Fault Isolation Detection 600kn Sensitivit ..Maximum Inverter.Efficiency........ .._.97.7.... ...98.2... .98.3 . 98.3 .....98.... ......98..... ......98...... ..%..... ........ ........... ........ .. .. .... .. .. ..... .. ................. ................ .............. .............. .. .. 5 @ 208V 97 @ 208V CEC Weighted Efficiency 97.5 98 97. 97.5 97.5 97.5 ........................................ ................ ............... ..98 @_240V.. ................ ................ ..97.5 @ 240V.. Nighttime Power Consumption <2.5 <4 1 W • ADDITIONAL FEATURES Supported Communication Interfaces RS485,RS232,Ethernet,ZigBee(optional) 1 ��.,,.,, - ........................................... ..........................................................P............................................................... ........... Revenue Grade Data,ANSI C12.1 Optional STANDARD COMPLIANCE Safety .......................................UL1741,,UL16996,UL1998,CSA 222 ........................................... ............................. . ......... ..... ........... . .... ........... GricGrid Connection Standards IEEE1547 ..onne............................. .......................................................................................................................... ........... Emissions FCC part15 class B INSTALLATION SPECIFICATIONS AC output conduit size/AWG range 3/4"minimum/246 AWG... 3/4"minimum/8 3 AWG............. ......... DC input conduit size/#of strings/ AWG range 3/4"minimum/1-2 strings/24-6 AWG 3/4"minimum/1-2 strings/14-6 AWG ........................................... ................................ .................................. ...................................................... ........... Dimensions with AC/DC Safety 30.5 x 12.5 x 7/ 1 30.5 x 12.5 x 7.5/ in/ 30.5x12.5x10.5/775x315x260 i Switch(HXWXD) 775 x 315 x 172 775 x 315 x191 mm ........................................... . ........ ......................... ...................................................... ........... Weight with AC/DC Safety Switch ....,,....51.2/23.2 ,,,,......54.7/24.7 ....................88.:4/40.1 Ib/kg ., ................................. ............... ................ . ............................ ........... Cooling Natural Convection Fans(userreplaceable) ........................................... ................................................................... . The best choice for SolarEdge enabled systems Noise <zs <5o dBA ........................................... ................................................................... ...................................................... ........... g y Min:Max.Operating Temperature -13 to+140/-25 to+60(CAN version—*-40 to+60) 'F/-C Integrated arc fault protection(Type 1)for NEC 2011690.11 compliance Range Superior efficiency(98%) Protection Rating. .. .. ........... ....... ..... MA..............................................NE3R........................................................ ........... For other regional settings please Contact SolarEdge support. Small,lightweight and easy to install on provided bracket "Limited to 125%for locations where the yearly average high temperature isabove 77'F/25'C and to 135%for locations where it is below 77'F/25'C. For detailed information,refer to htto.//wwwsolaredgeus/files/rails/inverter do overs'Yn au'de odf Built-in module-level monitoring Ahigher current source may be used;the Inverter will limit its input current to the values stated. ••CAN P/Ns are eligible for the Ontario FIT and micmFIT(microFIT exc.SE11400A-US-CAN). Internet connection through Ethernet or Wireless Outdoor and indoor installation Fixed voltage inverter,DC/AC conversion only Pre-assembled AC/DC Safety Switch for faster installation Optional—revenue grade data,ANSI C12.1 reo sunsaEc RoHS USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-ISRAEL www.solaredge.us