Loading...
HomeMy WebLinkAboutBuilding Permit #039-15 - 54 COMPASS POINT ROAD 7/11/2014 BUILDING PERMIT o` NORTH ,b TOWN OF NORTH ANDOVER APPLICATION FOR PLAN EXAMINATION �o e" Permit No#: Date Received �gSSgcHArE USS��y Date Issued: I PORTANT: Applicant must complete all items on this page LOCATION lid Print PROPERTY OWNER LLQ L Print -_2100 Year Structure yes rK MAP bCU PARCEL: 0 (05 ZONING DISTRICT: Historic District yes 04 Machine Shop Village yes t)6 TYPE OF IMPROVEMENT PROPOSED USE Residential Non- Residential fp'New Building ❑ One family ❑Addition XTwo or more family ❑ Industrial ❑Alteration No. of units: 7J ❑ Commercial ❑ Repair, replacement ❑Assessory Bldg ❑ Others: ❑ Demolition ❑ Other ❑ Septic ❑Well ❑ Floodplain lWetiands ❑ Watershed District ❑Water/Sewer DESCRIPTION OF WORK TO BE PERFORMED: &At-L-- ,40entification- Please Type or Print Clearly (_ OWNER: Name: UL Phone: 3�s� Address: Contractor Name:_ 'S,IL i'�, Phone: Som _SQc,1 8331 Address:_ P0 `,� Supervisor's Construction License: Exp. Date: LA Home Improvement License: Exp. Date: 1 ARCHITECT/ENGINEER kha,ocsxi N Lc� Lc.,, Phone: �`j� _35a Address: Q • &Uev- (-C� &#Do ` L.. Reg. No. ( " L J FEE SCHEDULE.BULDING PERMIT.$12.00 PER$1000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PER S.F. Total Project Cost: $ a(P5 ' 0 0 FEE: $ Check No.: 2-. Receipt No.: 2-7-7(A NOTE: Persons contracting with unregistered contractors do not have access to the g aranty fund Signature of Agent/Owner Signature of contractor Location ( �-t(�[, S pt No. 9 — Date i . - TOWN OF NORTH ANDOVER • Certificate of Occupancy $ DO Building/Frame Permit Fee $ 3/s- Foundation Permit Fee $ Other Permit Fee $ TOTAL Check# � I BLilding Inspector C i Plans Submitted ❑ Plans Waived ❑ Certified Plot Plan ❑ Stamped Plans ❑ TYPE OF SEWERAGE DISPOSAL Public Sewer ❑ Tanning/massage/Body Art ❑ Swiimning Pools 11 Well ❑ Tobacco Sales ❑ Food Packaging/Sales ❑ Private(septic tank,etc. ❑ permanent Dumpster on Site ❑ I THE FOLLOWING SECTIONS FOR OFFICE USE ONLY INTERDEPARTMENTAL SIGN OFF - U FORM PLANNING & DEVELOPMENT Reviewed On Signature_ COMMENTS CONSERVATION Reviewed on )( b� l Si nature /l-o--1 (�;Wd�- `t COMMENTS — l O� � ✓� t HEALTH Reviewed on Signature COMMENTS Zoning Board of Appeals: Variance, Petition No: Zoning Decision/receipt submitted yes Planning Board Decision: Comments Conservation Decision: Comments iD Water& Sewer Connection/signature& Date DrivewaV Permit DPW Town Engineer: Signature: Y--71 L ated 384 Osgood Street FIRE DEPARTMENT - Temp Dumpster o ite es no Located at 124 Main Street Fire Department signature/date COMMENTS Dimension Number of Stories: Total square feet of floor area, based on Exterior dimensions. a o") Total land area, sq. ft.: ELECTRICAL: Movement of Meter location, mast or service drop requires approval of Electrical Inspector Yes No DANGER ZONE LITERATURE: Yes No MGL Chapter 166 Section 21A—F and G min.$100-$1000 fine NOTES and DATA— (For department use) ❑ Notified for pickup Call Email Date Time Contact Name Doc.Building Pennit Revised 2014 Building Department The following is a list of the required forms to be filled out for the appropriate permit to be obtained. Roofing, Siding, Interior Rehabilitation Permits o Building Permit Application a Workers Comp Affidavit o Photo Copy Of H.I.C. And/Or C.S.L. Licenses o Copy of Contract o Floor Plan Or Proposed Interior Work u Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit Addition Or Decks o Building Permit Application u Certified Surveyed Plot Plan a Workers Comp Affidavit o Photo Copy of H.I.C. And C.S.L. Licenses o Copy Of Contract o Floor/Cross Section/Elevation Plan Of Proposed Work With Sprinkler Plan And Hydraulic Calculations (If Applicable) o Mass check Energy Compliance Report (If Applicable) o Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit New Construction (Single and Two Family) o Building Permit Application o Certified Proposed Plot Plan La Photo of H.I.C. And C.S.L. Licenses Li Workers Comp Affidavit o Two Sets of Building Plans (One To Be Returned) to Include Sprinkler Plan And Hydraulic Calculations (If Applicable) o Copy of Contract a Mass check Energy Compliance Report a Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg. Permit In all cases if a variance or special permit was required the Town Clerks office must stamp the decision from the Board of Appeals that the appeal period is over. The applicant must then get this recorded at the Registry of Deeds. One copy and proof of recording must be submitted with the building application Doc:Building Permit Revised 2014 OE HORTy 14, O ti 9 + + 'fig°y..n.•"S9 �SSACH°SES CERTIFICATE OF USE & OCCUPANCY TOWN OF NORTH ANDOVER Building Permit Number 039-15 on 7/11/2014 Date: July 15, 2015 . THIS CERTIFIES THAT THE BUILDING LOCATED ON 54 Compass Point— Building F MAY BE OCCUPIED AS a single family home IN ACCORDANCE WITH THE PROVISIONS OF THE MASSACHUSETTS STATE BUILDING CODE AND SUCH OTHER REGULATIONS AS MAY APPLY. Certificate Issued to: Berry CO,LLC 51 Mount Joy Drive Tewksbury, MA 01876 Building Inspector I Fee: PrePaid $100.00 Receipt: 27768 Check : 7772 :J NORT11 i own of E �tAndover G ` h ver, Mass, COC KI C.JWICK 01� 7�A0#ArEo S U BOARD OF HEALTH Food/Kitchen PERMIT T LD Septic System .............. LL-It THIS CERTIFIES THAT . I....., J Bu LDINNWily/� � has permission to erect buildings on ......... GESS . �,,.:qn dation , .......................... : ..... ..................................... . n n � h Jam- • ✓ern L� /%�� / to be occupied as ......... t)................................................................ chi ney provided that the person accepting this permit shall in every respect conform to the terms of the application ina I/ on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection, Alteration and Construction of Buildings in the Town of North Andover. PLUMBING IINSP CTOR Rough �!f�f VIOLATION of the Zoning or Building Regulations Voids this Permit. Final p4K I/Al I PERMIT EXPIRES IN 6 MONTHS ELECTRICAL INSPECTOR UNLESS CONSTRUCTION STS Service ..................... ..... . . .......?... .. t?•rt,..................... BUILDING INSPECTOR GAS INSPECTOR Occupancy Permit Required to Occupy Building [!F o � fd�,�, `'`y Display in a Conspicuous Place on the Premises — Do Not Remove in,1 4(ir"111 No Lathing or Dry Wall To Be Done FIRE DEPARTMENT. Until Inspected and Approved by the Building Inspector. Burner e Street No. Smoke Det —1 ✓�/l��l Z� - 7� NORTH Town of E : ,, n over G Yf 0 No. h ver, Mass, 2b 14 cocNic«ewic« �1- �,9 S U BOARD OF HEALTH Food/Kitchen PERMIT T D Septic System THIS CERTIFIES THAT BUILDING INSPECTOR ............. ... . . ........��. ....L ............................. ........................ has permission to erect buildings on ......... G►5S e+. —w i: Rough tobe occupied as ......... M....C 0............................................................... Chimney provided that the person accepting this permit shall in every respect conform to the terms of the application Final on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection, Alteration and Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR VIOLATION of the Zoning or Building Regulations Voids this Permit. Rough Final PERMIT EXPIRES IN 6 MONTHS ELECTRICAL INSPECTOR UNLESS CONSTRUCTION STS Rough Service ..................... ..... ....... ... .. t?_rt........................ Final BUILDING INSPECTOR GAS INSPECTOR Occupancy Permit Required to Occupy Building Rough Display in a Conspicuous Place on the Premises — Do Not Remove Final No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. Burner Street No. Smoke Det. NORTH Town of s ndover O - 0 6 ,� oh ver, Mass, l coc«ic«lWIC« �1• �f.Qs R�reo rPa,��(5 U BOARD OF HEALTH Food/Kitchen Septic System P RM IT LD THIS CERTIFIES THAT .......00.mAdaue. . .. h! ....��.. � � ....... BUILDING INSPECTOR .. .......... !. ........... ........ .... ...... � oundation has permission to erect 5-'10 ................... buildings on ... . ,..... �... ....�..... ... ..... 4 Mwv ough to be occup,ed as ....... vQ� t ....... .......... ........................................... Chimney provided that the person accepting this permit shall in every re ct conform to the terms of the application Final on file in thi� office, and to the provisions of the Codes and By-Laws relating to the Inspection,Alteration and Constructio i of Buildings in the Town of North Andover. PLUMBING INSPECTOR VIOLATION Df the Zoning or Building Regulations Voids this Permit. Rough Final ppb.. PERMIT EXPIRES IN 6 MONTHS ELECTRICAL INSPECTOR UNLESS CONSTRUCTIO S Rough Service .................... .. ..... ................................. Final BUILDING INSPECTOR GAS INSPECTOR Occupancy Permit Required to Occupy Building Rough Display in a Conspicuous Place on the Premises — Do Not Remove Final No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. Burner Street No. Smoke Det. SEE REVERSE SIDE ACCP a® CERTIFICATE OF LIABILITY INSURANCE �' '°"""Y"' 4714 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER THIS CERTIFICATE DOES NOT AFRWAATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW THIS.CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT- N the certificate holder is an ADDITIONAL INSURED,the policyges)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions ofthe policy,certalnpolicies may require an endorsement. A statement on this certificate does not confer riots to the certificate holder in lieu of such endorsement(s). PRODUCER N Coonan Insurance Agency, Inc. visD ----`_-----.-__--__-_--._-- ---- - Fnx - - --"--- 267 Main Street 0 87-7 22 (5508)09) 98877-7152 Oxford, MA 01540 Mss: cindy0coonaninsurance.com ---_NAICN.--- INW MA_Travelers ------ ---- --- - - ----- - WSUREO INSURER 6 TJK, Inc. INaIn:ERc• ------- ---- ----- --PO Box Sox 12 --INSUM D---, ---------- -----------_- _ -- : South Grafton, MA 01560 INSII ERF: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY-REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS. EXCLUSIONS ANO CONDITIONS OF SUCH POLICIES.LFAITS SHOWN MAY HAVE BEEN REDUCED_ BYPAIDCLAIMS. R_...- AWE SIM - -- - --PO y EFF POLICY ppi�pp L TYPEOFINSURAHCE P'OUCYNMER MIDDY MMANDJYYW UMTS A GMERALIJ"B1UTM 680-335MI703-13 11/3/13 11/3/14 FACH000UrIRENCE $ , 1 000 000 00 - X_ COMMERCIAL GENERALLIABILITY 15AK61ETO RENTED �OGrUR Ise�tr�loowa�,�-_ -3�0000 CIAaAStiIADE VEDoe�roreperson) s_-__5-000 __-- --_-__-- PERSONALBADVIKURY i 1,00_0 -- •--------------•__-- cv_�aAL A(idlEGATE_ _s-. 2,000_000 GEWLAGGREGATELIMTAPPLIESPER PRODUCTS-ODMP1OPAGG f 2.000,000 POLICY LOC ------- - i AUTOMONLELIAeWTY ANY AUTO BODILY INJURY(Per panwl)ALLf AUTOS D AUTOS D BODILY INJURY(Per acIXderd) ~----- NDN-OV NED PERTY DAMA f-- HIREDAUTOS ,_AUTOS eracaOergL—_---_--_---_--� f UWRELLALIAB OCCUR EAGHOCCURRENCE f EIa1E33LlAH - YXAIMSMADE AGGREGATE f A vMKERS CoNs" IE-ITB-9914N01-3-14 1/26/14 1/26/15 X STATU- OTH ANDEMPLOYEWLIA911M YIN -. SORYIallTB.- R _---_�.— ANYPROPRIETDwPARTNERIEXECUTME E� aca[Ewr -- .S—._.100 000 OFMRIMEMBER EXCLUDED? NIA ►---•---..- (Mand.lory In NH) _E.L.0ISE16M-EA 1EW10YE_ 6_ 100.000 U and NorRAT below E.L.r%-qEAsE-PoucYLwrr s 500,000 A Contractors Equipment QT-660-2D283058 5/8/13 5/8/14scheduled 100,000 equipment UESCRIPTION OF OPERATIONS I UXATWNS I I unh ACORD 101,AdMbW Renarb Sdn",IF nom space Rmgdmd) CERTIFICATE HOLDER CANCELLATION N SHOULD ANY OF 7HE ABOVE DESCRIBED POLICES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Town of North Andover ACCORDANCE WITH THE POLICY PROVISIONS. 120 Main Street North Andover, MA 01.845 AUTHORIZED REPRESENTAYM Cind y Davis ®1888-2010 ACORD CORPORATION. All fights reserved. ACORD 25(2010105) The AC ORD_name and logo are registered marks of ACORD Phone: Fax: E-Mail: tbbuildina@atol.com 1 RE check Software Version 4.4.4 Compliance Certificate Project Title: 130625 Trust Merrimack Energy Code: 2009 IECC Location: North Andover,Massachusetts Construction Type: Multi Family Project Type: New Construction Conditioned Floor Area: 2,127 ft2 Glazing Area Percentage: 10% Heating Degree Days: 6322 Climate Zone: 5 Permit Date: Construction Site: Owner/Agent: Designer/Contractor. Unit C1 North Andover,MA 166W.jh �Em won,'W mapa Compliance: 3.8%Better Than Code Maximum UA: 338 Your UA:325 The%Better or Worse Than Code Index reflects how dose to compliance the house is based on code trade-oft rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Cont.Gross Cavity Assembly Area or or Door UAPerimeter Floor SLAB:Slab-On-Grade:Unheated 48 10.0 37 Insulation depth:2.0' Wall LOWER LEVEL 2X6 EXT:Wood Frame,16"o.c. 384 19.0 0.0 23 Window DH:Vinyl Frame:Double Pane with Low-E 48 0.290 14 SHGC:0.00 Wall SEPARATION 2X6:Wood Frame,16"o.c. 280 19.0 0.0 17 Wall GARAGE 2X4:Wood Frame,16"o.c. 104 15.0 0.0 8 Wall 1 ST FLOOR 2X6:Wood Frame,16"o.c. 464 19.0 0.0 28 Window DH:Vinyl Frame:Double Pane with Low-E 27 0.290 8 SHGC:0.00 Window BAY:Vinyl Frame:Double Pane with Low-E 28 0.270 8 SHGC:0.00 Wall 1 ST FLOOR SEPARATION 2X6:Wood Frame,16"o.c. 488 19.0 0.0 29 Wall 2ND FLOOR 2X6:Wood Frame.16"o.c. 464 19.0 0.0 28 Window DH:Vinyl Frame:Double Pane With Low-E 95 0.290 28 SHGC:0.00 Wall 2ND FLOOR SEPARATION 2X6:Wood Frame,16"o.c. 488 19.0 0.0 29 Ceiling ABOVE 2ND FLOOR:Flat Ceiling or Scissor Truss 803 38.0 0.0 24 Project Title: 130625—Trust—Merrimack— Report date: 09/28/13 Data filename: &XEbbeling_E030625 Trust Merrimack C\RESchecks1130625 Trust Merrimack- C UnitCl.rck Page 1 of 8 Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2009 IECC requirements in REScheck Version 4.4.4 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name-Title Signature Date Project Notes: Unit C1 Project Title: 130625—Trust_Merrimack_C1 Report date: 09/28/13 Data filename: S:\Ebbeling_Ed\130625_Trust Merrimack C\RESchecks\130625_Trust_Merrimack_C_UnitCi.rck Page 2 of 8 REScheck Software Version 4.4.4 Inspection Checklist Requirements: 0.0% were addressed directly in the REScheck software Text in the"Comments/Assumptions"column is provided by the user in the REScheck Requirements screen.For each requirement,the user certifies that a code requirement will be met and how that is documented,or that an exception is being claimed.Where compliance is itemized in a separate table,a reference to that tableis provided. 2009 IECC Pre-Inspection/Plan Review Plans Verged Field Verged Complies? Comments/Assumptions Value Value 103.2 Construction drawings and ❑Complies [PR1]1 documentation demonstrate energy Thoes Not Comply ,9 code compliance for the building []Not Observable envelope. []Not Applicable 103.2, Construction drawings and ❑Complies 403.7 documentation demonstrate energy ❑Does Not Comply [PR3]' code compliance for lighting and mechanical systems.Systems serving ❑Not Observable multiple dwelling units must []Not Applicable demonstrate compliance with the commercial code. 403.6 Heating and cooling equipment is Heating: Heating: ❑Complies [PR2]2 sized per ACCA Manual S based on Btu/hr Btu/hr []Does Not Comply J loads per ACCA Manual J or other Cooling: Cooling: []Not Observable approved methods. Btu/hr Btu/hr []Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3 Project Title: 130625—Trust—Merrimack—Cl Report date: 09/28/13 Data filename: S:\Ebbeling_Ed\130625_Trust Merrimack C\RESchecks\130625 Trust Merrimack C_UnitCl.rck Page 3 of 8 2009 IECC Foundation Inspection Plans Verified Field Verified Complies? Comments/Assumptions Value Value 402.1.1 Slab edge insulation R-value. R- R- ❑Complies See theFwel�nP AccAmhGa�table for [FO1]1 ❑ Unheated ❑ Unheated ❑Does Not Comply values. ❑ Heated ❑ Heated ❑Not Observable ❑Not Applicable 303.2, Slab edge insulation installed per ❑Complies 402.2.8 manufacturer's instructions. []Does Not Comply [FO2]1 ❑Not Observable ❑Not Applicable 402.1.1 Slab edge insulation depth/length. ft ft ❑Complies See the FnvPlnnr.A.ccamhliP.c table for [FO3]' ❑Does Not Comply values. ❑Not Observable ❑Not Applicable 303.2.1 A protective covering is installed to ❑Complies [FO11]2 protect exposed exterior insulation 40Does Not Comply and extends a minimum of 6 in.below ❑Not Observable grade. ❑Not Applicable 403.8 Snow-and ice-melting system ❑Complies [FO12]2 controls installed. ❑Does Not Comply ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: 130625—Trust—Merrimack—Cl Report date: 09/28/13 Data filename: S:\Ebbeling_Ed\130625_Trust_Merrimack C\RESchecks\130625_Trust_Merrimack C_UnitC1.rck Page 4 of 8 20091ECC Framing I Rough-In Inspection Plans Verified Field VerifiedValue Value Complies? Comments/Assumptions 402.1.1, Door U-factor. U- U- ❑Complies See the table for 402.3.4 ❑Does Not Comply values. [FR1]' []Not Observable []Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envalnne Accamhliac table for 402.3.1, average). ❑Does Not Comply values. 402.3.3, ❑Not Observable 402.5 402.5 [:]Not Applicable to 303.1.3 U-factors of fenestration products are ❑Complies [FR4]1 determined in accordance with the ❑Does Not Comply NFRC test procedure or taken from ❑Not Observable the default table. []Not Applicable 402.3.5 Sunrooms enclosing conditioned U- U- ❑Complies [FR8]' space have a maximum fenestration ❑Does Not Comply U-factor of 0.50 in Climate Zones 4-8. ❑Not Observable New glazing separating the sunroom from conditioned space must meet []Not Applicable code requirements. 402.3.5 Sunrooms enclosing conditioned U- U- ❑Complies [FR9]1 space have a maximum skylight U- ❑Does Not Comply factor of 0.75 in Climate Zones 4-8. ❑Not Observable ❑Not Applicable 402.4.4 Fenestration that is not site built is ❑Complies [FR20]1 listed and labeled as meeting ❑Does Not Comply AAMANVDMA/CSA 101/I.S.2/A440 or ❑Not Observable has infiltration rates per NFRC 400 that do not exceed code limits. +❑Not Applicable 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish and ❑Does Not Comply labeled to indicate 2.0 cfm leakage at []Not Observable 75 Pa. []Not Applicable 403.2.1 Supply ducts in attics are insulated to R- R- ❑Complies [FR12]' R-8.All other ducts in unconditioned R- R- ❑Does Not Comply 10 spaces or outside the building ❑Not Observable envelope are insulated to R-6. []Not Applicable 403.2.2 All joints and seams of air ducts,air ❑Complies [FR13]' handlers,filter boxes,and building ❑Does Not Comply cavities used as return ducts are []Not Observable sealed. []Not Applicable 403.2.3 Building cavities are not used for ,❑Complies [FR15]3 supply ducts. ❑Does Not Comply 9J []Not Observable []Not Applicable 403.3 HVAC piping conveying fluids above R- R- ❑Complies [FR17]2 105 IF or chilled fluids below 55 OF ❑Does Not Comply J are insulated to R-3. ❑Not Observable ❑Not Applicable 403.4 Circulating service hot water pipes are R- R- ❑Complies [FR18]2 insulated to R-2. ❑Does Not Comply 9 []Not Observable ❑Not Applicable 403.5 Automatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air intakes and DDoes Not Comply exhausts. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 12 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 130625_Trust Merrimack C1 Report date: 09/28/13 Data filename: S:\Ebbeling_Ed\130625 Trust Merrimack C\RESchecks\130625 Trust Merrimack C_UnitC1.rck Page 5 of 8 2009 IECC Insulation Inspection Plans Verified Field Verified Complies? Comments/Assumptions Value Value L_ 303.1 All installed insulation is labeled or the ❑Complies [IN13]2 installed R-values provided. []Does Not Comply 9� ❑Not Observable ❑Not Applicable 402.1.1, Wall insulation R-value.If this is a R- R- ❑Complies See the table for 402.2.4, mass wall with at least%of the wall ❑ Wood ❑ Wood ❑Does Not Comply values. 402.2.5 insulation on the wall exterior,the ❑ Mass ❑ Mass ❑Not Observable [I N3]1 exterior insulation requirement applies. ❑ Steel ❑ Steel []Not Applicable 303.2 Wall insulation is installed per ❑Complies [IN4]1 manufacturer's instructions. ❑Does Not Comply []Not Observable ❑Not Applicable 402.2.11 Sunroom wall insulation has a R- R- []Complies [IN8]1 minimum R-value of R-13.New walls ❑Does Not Comply separating the sunroom from ❑Not Observable conditioned space must meet code ❑Not Applicable requirements. 303.2 Sunroom wall insulation installed per ❑Complies [IN9]1 manufacturer's Instructions. []Does Not Comply ❑Not Observable ❑Not Applicable 402.2.11 Sunroom ceiling minimum insulation R- R- ❑Complies [IN10]1 R-value of R-19 in Climate Zones 1-4, ❑Does Not Comply 10 and R-24 in Climate Zones 5-8. ❑Not Observable ❑Not Applicable 303.2 Sunroom ceiling insulation is installed ❑Complies [IN11]1 per manufacturer's instructions. ❑Does Not Comply 9i ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: 130625_Trust Merrimack C1 Report date: 09/28/13 Data filename: S:\Ebbeling_Ed\130625_Trust Merrimack_C\RESchecks\130625_Trust Merrimack C_UnitCl.rck Page 6 of 8 l _r 2009 IECC Final Inspection Provisions Plans Verified Field Verified Complies? Comments/Assumptions Value Value 402.1.1, Ceiling insulation R-value.Where>R- R- R- []Complies See the table for 402.2.1, 30 is required,R-30 can be used if Wood Wood []Does Not Comply values. 402.2.2 insulation is not compressed at eaves. Steel ❑ Steel []Not Observable [FI1]' R-30 may be used for 500 ft'or 20% (whichever is less)where sufficient [:]Not Applicable space is not available. 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions.Blown ❑Does Not Comply [FI2]' insulation marked every 300 ft2. ❑Not Observable 0 ❑Not Applicable 402.2.3 Attic access hatch and door insulation R- R- ❑Complies [FI3]' R-value of the adjacent assembly. ❑Does Not Comply U ❑Not Observable ❑Not Applicable 402.4.2, Building envelope tightness verified ACH 50,= ACH 50= ❑Complies 402.4.2.1 by blower door test result of<7 ACH ❑Does Not Comply [FI17]' at 50 Pa.This requirement may []Not Observable 19 instead be met via visual inspection, ❑Not Applicable in which case verification may need to occur during Insulation Inspection. 402.4.3 Wood-burning fireplaces have ❑Complies [FI8]2 gasketed doors and outdoor []Does Not Comply J combustion air. ❑Not Observable ❑Not Applicable 403.2.2 Post construction duct tightness test cfm cfm ❑Complies [F14]' result of 8 cfm to outdoors,or 12 cfm ❑Does Not Comply across systems.Or,rough-in test []Not Observable result of 6 cfm across systems or 4 cfm without air handler.Rough-in test ❑Not Applicable verification may need to occur during Framing Inspection. 403.1.1 Programmable thermostats installed ❑Complies [F19]2 on forced air furnaces. ❑Does Not Comply ,Qj ❑Not Observable []Not Applicable 403.1.2 Heat pump thermostat installed on ❑Complies [FI10]2 heat pumps. ❑Does Not Comply V ❑Not Observable ❑Not Applicable 403.4 Circulating service hot water systems ❑Complies (Fit 1]2 have automatic or accessible manual ❑Does Not Comply 9 controls. ❑Not Observable ❑Not Applicable 403.9.1 Readily accessible switch on heaters ❑Complies [FI12]3 for swimming pools. []Does Not Comply []Not Observable ❑Not Applicable 403.9.2 Timer switches on pool heaters and ❑Complies [FI19]3 pumps are present. ❑Does Not Comply 6y []Not Observable []Not Applicable 403.9.3 Heated swimming pools have a cover. ❑Complies [F120]3 Covers on pools heated over 90 OF ,❑Does Not Comply 10) are insulated to R-12. ❑Not Observable []Not Applicable 404.1 50%of lamps in permanent fixtures ❑Complies are high efficacy lamps. Thoes Not Comply 0Not Observable ❑Not Applicable 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) i Project Title: 130625_Trust Merrimack C1 Report date: 09/28/13 Data filename: S:\Ebbeling_Ed\130625_Trust Merrimack_C\RESchecks\130625_Trust Merrimack C_UnitC1.rck Page 7 of 8 i 20091ECC Final Inspection Provisions Plans Verified Field Verified Complies? Comments/Assumptions Value Value 401.3 Compliance certificate posted. I ❑Complies [F17]2 ❑Does Not Comply ❑Not Observable .[:]Not Applicable 303.3 Manufacturer manuals for mechanical ❑Complies [FI18]3 and water heating equipment have ❑Does Not Comply been provided. ❑Not Observable []Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: 130625—Trust—Merrimack—Cl Report date: 09/28/13 Data filename: S:\Ebbeling_Ed\130625 Trust Merrimack C\RESchecks\130625_Trust Merrimack C_UnitCl.rck Page 8 of 8 1 a 2009 ECC Cinergy Efff dency Certfflcate Insulation, . Wall 19.00 Floor 10.00 Ceiling/Roof 38.00 Ductwork(unconditioned spaces): Window 0.29 Door 0.29 Heating System: Cooling System: Water Heater: Name: Date: Comments: 1 a ✓ REScheck Software Version 4.5.0 Compliance Certificate Project 140707 Trust MerrimackCondos_BIdgD_UnitsB-E-E_NAndover Energy Code: 2009 1ECC Location: North Andover, Massachusetts Construction Type: Multi-family Project Type: New.Construction Conditioned Floor Area: 2,159 ft2 Glazing Area 10% Climate Zone; 5 (6322 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 54-F3 North Andover, MA •. .• .,•:;, ,• • 4�+.,`s,�„���` a�xa> � Vit' r > s;, 'a: ,ia;-�� Compliance: 0.3%Better Than.Code Maximum UA:. 328 Your UA: 327 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Glazing Cavity Cont. Assembly or or Door UA Floor 1st Floor:All-Wood Joist/Truss:Over Unconditioned Space 534 38.0 0.0 0.026 14 Wall 1st Separation:Wood Frame, 16”D.C. 612 15.0. 0.0 0.077 47 Wall 1st Ext 2x6:Wood Frame,16"o.c. 480 21.0 0.0 0.057 22 Door Front Ground Fir entry: Glass 34 0.210 7 Door Metal: Solid 18 0.160 3 Door Slider:Glass 40 0.290 12 Floor 2nd Over garage:All-Wood J oist/Tru ss:Over Unconditioned Space 554 38.0 0.0 0.026 14 Wall 2nd Floor 2x6:Wood Frame,16"o.c. 585 21.0 0.0 0.057 26 Window DH:Vinyl Frame:Double Pane with Low-E 34 0.290 10 Window Fix:Vinyl Frame:Double Pane with Low-E 19 0.280 5 Window CSMT:Vinyl Frame:Double Pane with Low-E 12 0.260 3 Door Slider: Glass 68 0.290 20 Wall 2nd Fir Separation:Wood Frame, 16"o.c.. 495 15.0 0.0 0.077 38 Ceiling Bay Win: Flat Ceiling or Scissor Truss 6 30.0 0.0 0.035 0 Wall 3rd Floor:Wood Frame,16"D.C. 496 21.0 0.0 0.057 23 Window DH:Vinyl Frame:Double Pane with Low-E 80 0.290 23 Window Awn:Vinyl Frame:Double Pane with Low-E 7 0.270 2 Wall 3rd Separation:Wood Frame, 16"o.c. 440 15.0 0.0 0.077 34. Project Title: 140707 Trust_.MerrimackCondos_BldgD_UnitsB-E-E_NAndover Report date: 09/0.9/14 Data filename: S:\Ebbeling_Ed\140707 Trust MerrimackCondos_BIdgF_Unitsl3-E- Page ! of 9 E_NAndover\REScheck\140909 Trust Merrimac_Bldg4_UnitF3_54.rck f Gross Area Cavity Cont. Glazing Assembly or R-Value R-Value or Door UA Perimeter U-Factor Ceiling . o Ceiling Main: Flat Ceiling or Scissor Truss 810 38.0 0.0 0.030 24 Compliance Statement. The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2009 IECC requirements in REScheck Version 4.5.0 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name-Title Signature Date Project Notes: Building D Project Title: 140707 Trust=MerrimackCondos_B.IdgD_UnitsB-E-E_NAndover Report date: 09/09/14 Data filename: S:\Ebbeling_Ed\140707 Trust_MerrimackCondos BldgF_UnitsB-E- Page 2 of 9 E_NAndover\REScheck\140909 Trust Merrimac_BIdgD_UnitF3 54.rck ciREScheck Software Version 4.5.0 Inspection Checklist Energy Code: 2009 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the"Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.ID 103.2 ;Construction drawings and '!(]Complies [PR111 documentation demonstrate ODoes Not 41 :energy code compliance for the ;building envelope. f , Not Observable iONot Applicable 103.2, ;Construction drawings and ;[]Complies 403.7 documentation demonstrate i ODoes Not [PR3]1 I energy code compliance for + �pNot Observable ,lighting and mechanical systems. , ? Systems serving multiple UNot Applicable ;dwelling units must demonstrate compliance with the commercial code. 403.6 ;Heating and cooling equipment is; Heating: Heating: ;[]Complies [PR2]2 sized per ACCA Manual S based Btu/hr I Btu/hr ODoes Not ;on loads per ACCA Manual J or Cooling: Cooling: other approved methods. Btu/hr Btu/hr Not Observable ;[]Not Applicable ; Additional Comments/Assumptions: 1 I High Impact(Tier 1) 12 1 Medium Impact(Tier 2) 13 1 Low Impact Crier 3) Project Title: 140707—Trust.MerrimackCondos_B1dgD_UnitsB-E-E_NAndover Report date: 09/09./14 Data filename: S:\Ebbeling_Ed\140707 Trust MerrimackCondos_BldgF_UnitsB-E- Page 3 of 9 E_NAndover\REScheck\140909 Trust Merrimac BIdgD_UnitF3_54.rck t 009 IECC Foundation Inspection Complies? Comments/Assumptions 303.2.1 ;A protective covering is installed to ;❑Complies [FO11]2 protect exposed exterior insulation ❑Does Not and extends a minimum of 6 in. below ; grade. UNot Observable; ❑Not Applicable 403.8 ;Snow-and ice-melting system controls;❑Complies [FO12]2 installed. ;❑Does Not ;❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low.lmpact.(Tier 3) Project Title: 140707 Trust MerrimackCondos_BldgD_UnitsB-E-E_NAndover Report date:. 09/09/14 Data filename: S:\Ebbeling_Ed\140707 Trust MerrimackCondos_BldgF_UnitsB-E- Page 4 of 9 E_NAndover\REScheck\140909_Trust Merrimac BIdgD_UnitF3_54.rck r «w Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value- Complies? Comments/Assumptions &Req.ID 402.1.1, Door U-factor. U- U- ❑Complies ;See the Envelope Assemblies 402.3.4 ;❑Does Not table for values. [FR1]1 j❑NotObservable ❑Not Applicable 402.1.1, ,Glazing U-factor(area-weighted U- U- ❑Complies ;See the Envelope Assemblies 402.3.1, average). ;❑ ;table for values. 402.3.3, Does Not 402.5 ;❑Not Observable ' [FR211 ❑Not Applicable : 303.1.3 ;U-factors of fenestration products' ❑Complies ; [FR411 :are determined in accordance I❑Does Not ;with the NFRC test procedure or ;taken from the default table. g t❑Not Observable ❑Not Applicable 402.3.5 ;Sunrooms enclosing conditioned U- U- ❑Complies [FR8]1 :space have a maximum T❑Does Not ;fenestration U-factor of 0.50 in ;Climate Zones 4-8.New glazing ;❑Not Observable separating the,sunroom from ;❑Not Applicable ;conditioned space must meet code requirements. 402.3.5 ;Sunrooms enclosing conditioned U- U- ;❑Complies [FR911 :space have a maximum skylight ;❑Does Not U-factor of 0.75 in Climate Zones j ;4-8 ❑Not Observable ❑Not Applicable 402.4.4 Fenestration that is not site built '❑Complies [FR20]1 is listed and labeled as meeting r I❑Does Not :AAMA/WDMA/CSA 101/I.S.2/A440. or has infiltration rates per NFRC i ❑Not Observable ; :400 that do not exceed code ❑Not Applicable ;limits. r• 402.4.5 ;IC-rated recessed lighting fixtures? II❑Complies [F ]2 :sealed at housing/interior finish !❑Does Not and labeled to indicate s2.0 cfm 1 III leakage at 75 Pa. I❑Not Observable ❑Not Applicable 403.2.1 ;Supply ducts in attics are R- R- ;❑Complies [FR12]1 :insulated to>_R-8.All other ducts R- ; R- ;❑Does Not :in unconditioned spaces or ;outside the building envelope are: ❑Not Observable :insulated to>R-6. ;❑Not Applicable 403.2.2 :All joints and seams of air ducts, ❑Complies [FR13]1 :air handlers,filter boxes,and f❑Does Not > :building cavities used as return ;ducts are sealed. ❑Not Observable ❑Not Applicable 403.2.3 ;Building cavities are not used for ; '❑Complies [FR15]3 :supply ducts. '❑D.oes Not- 0 � k❑Not Observable ❑Not Applicable 403.3 ;HVAC piping conveying fluids : R- R- ;❑Complies [FR17]z :above 105 QF or chilled fluids ❑Does Not below 55.°F are insulated to '>_R- ❑Not Observable 3 ;❑Not Applicable 403.4 ;Circulating service hot water R- • R- ❑Complies [FR18]2 ;pipes are insulated to R-2. j❑Does Not ;❑Not Observable ❑Not Applicable i 11 High Impact.(Tier 1) 2 Medium Impact(Tier 2) 3. 1 Low impact.(Tier 3) I Project Title: 140707 Trust_MerrimackCond.os_BldgD_UnitsB-E-E,NAndover Report date: 09/09/14 Data filename: S:\Ebbeling_Ed\140707 Trust MerrimackCondos_BldgF_UnitsB-E- Page 5 of 9 E_NAndover\REScheck\140909 Trust_Merrimac_BldgD_UnitF3_54.rck v M Section ming/Rough-In Inspection Plans Verified Field Verified # FraValue Value Complies? & Req.ID Comments/Assumptions 403.5 ;Automatic or gravity dampers are; '❑Complies [FR19)2 !installed on all outdoor air ;❑Does Not j ;intakes and exhausts. i #❑Not Observable ; ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact.(Tier 2) 3 Low Impact(Tier 3.) Project Title: 140707 Trust_MerrimackCondos_BldgD_U.nitsB-E-E_NAndover Report date: 09/09/14 Data filename: 5:\Ebbpling_Ed\140707 Trust_MerrimackCondos_BldgF_UnitsB-E- Page 6 of 9 E_NAndover\REScheck\140909 Trust Merrimac BldgD_UnitF3 54.rck y Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions &Re .ID 303.1 ;All installed insulation is labeled ❑Complies [IN13]2 or the installed R-values `❑Does Not provided. i❑Not Observable a❑Not Applicable 402.1.1, ;Floor insulation R-value. R, R- ;❑Complies ;See the EnvelopeAssemblies 402.2.5, ❑ Wood Wood ;❑Does Not ;table for values. 402.2.6 n Steel ;❑ Steel [IN1]1 EI Observable , ❑Not Applicable ; 303.2, ;Floor insulation installed per ; ;❑Complies 402.2.6 manufacturer's instructions, and bDoes Not [IN2]1 :in substantial contact with the I 1 underside of the subfloor. I ❑Not Observable ❑Not Applicable 402.1.1, ;Wall insulation R-value.If this is a; R- R- ;❑Complies :See the Envelope Assemblies 402.2.4, mass wall with at least 1/2 of the :E] Wood ❑ Wood ❑Does Not ;table for values. 402.2.5 ;wall insulation on the wall :[-1 Mass ;❑ Mass :❑Not Observable [IN3]1 ;exterior,the exterior insulation ; requirement applies. ;❑ ❑ Steel Steel ❑Nat Applicable ; , 303.2 Wall insulation is installed per 4 4❑Complies [IN4]1 manufacturer's instructions. I❑Does Not , ❑Not Observable ❑Not Applicable 402.2.11 ;Sunroom wall insulation has a R- R- ;❑Complies (IN8]1 :minimum R-value of R-13.New ;❑Does Not ;walls separating the sunroom ;from conditioned space must ;❑Not Observable meet code requirements. �❑Not Applicable 3032 ;Sunroom wall insulation installed ❑Complies ; [IN9]1 ;per manufacturer's Instructions. s E❑Does Not :[-]Not Observable h i❑Not Applicable 402.2.11 ;Sunroom ceiling minimum R- R- ❑Complies [IN10]1 ;insulation R-value of R-19 in ; ❑Does Not 119 ; Climate Zones 1-4,and R-24 in Climate Zones 5-8. ❑Not Observable ❑Not Applicable 303.2 ;Sunroom ceiling insulation is "' ❑Complies [IN11]1 installed per manufacturer's ❑Does Not instructions. I ;[:]Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: 140707 Trust MerrimackCondos_BldgD._UnitsB-E-E NAndover Report-date: 09./09/.14 Data filename: S:\Ebbeling_Ed\140707 Trust MerrimackCondos_BIdgF_UnitsB-E- Page 7 of 9 E_NAndover\REScheck\140909 Trust Merrimac BIdgD_UnitF3_54.rck i Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions &Req.ID 402.1.1, ;Ceiling insulation R-value.Where R- R- ;❑Complies ;Seethe Envelope Assemblies 402.2.1, ;>R-30 is required,R-30 can be ❑ Wood ❑ Wood ;❑Does Not table for values. 402.2.2 used if insulation is not Steel E] Steel [Fill' ;compressed at eaves.R-30 may ❑Not Observable be used for 500 ft2 or 20% ;❑Not Applicable (whichever is less)where ;sufficient space is not available. 303.1.1.1,;Ceiling insulation installed per i ]❑Complies 303.2 ;manufacturer's instructions. r ❑Does Not (FI2]' ;Blown insulation marked every 1-4 1300 ft2. ❑Not Observable p I❑Not Applicable 402.2.3 ;Attic access hatch and door R- R- ❑Complies [FI3]' :insulation >_R-value of the ❑Does Not ;adjacent assembly. R' ;❑Not Observable ❑Not Applicable 402.4.2, ;Building envelope tightness ACH 50 = ACH 50 = ❑Complies 402.4.2.1 verified by blower door test result; ❑Does Not [FI17]' ;of<7 ACH at 50 Pa.This 1 requirement may instead be met {❑Not Observable I ;via visual inspection, in which ;❑Not Applicable case verification may need to ; I ;occur during Insulation Inspection. 402.4.3 ,Wood-burning fireplaces have ;❑Complies [FI8]2 :gasketed doors and outdoor a I❑Does Not combustion air. I ❑Not Observable j❑Not Applicable 403.2.2 Post construction duct tightness cfm cfm ❑Complies [FI4]' test result of:58 cfm to outdoors, ❑Does Not or<_12 cfm across systems.Or, rough-in test result of:56 cfm ❑Not Observable across systems or:54 cfm ;❑Not Applicable without air handler.Rough-in test ;verification may need to occur during Framing Inspection. 403.1.1 ;Programmable thermostats ❑Complies [FI9]2 ;installed on forced air furnaces. f❑Does Not '(4) t SE]Not Observable 1❑Not Applicable 403.1.2 ;Heat pump thermostat installed ! ❑Complies [FllO]2 :on heat pumps. ❑Does Not 1J ❑Not Observable ❑Not Applicable 403.4 ;Circulating service hot water ❑Complies [FI11]2 :systems have automatic or 1❑Does Not accessible manual controls. 10� ❑Not Observable ; s❑Not Applicable 403.9.1 ;Readilyaccessible switch on ; ❑Complies [FI12]3 :heaters for swimming pools. r ❑Does Not ❑Not Observable i ❑Not Applicable 403.9.2 ;Timer switches on pool heaters ;❑Complies [FI19]3 :and pumps are present. "❑Does Not ❑Not Observable I T❑Not Applicable 1.1 High-Impact(Tier 1) 2 Medium Impact(Tier 2) 13 1 Low Impact(Tier 3). Project Title: 14070.7 Trust_MerrimackCondos_B.IdgD_UnitsB-E-E NAndover Report date: 09/09/14 Data filename: S:\Ebbeling_Ed\140707 Trust MerrimackCondos_BldgF_UnitsB-E- Page 8 of 9 E_NAndover\REScheck\140909 Trust_Merrimac_BldgD_UnitF3_54.rck Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.9.3 :Heated swimming pools have a i ❑Complies [F120]3 cover.Covers on pools heated ! ❑Does Not j over 90 QF are insulated to R-12. ❑Not Observable ❑Not Applicable 404.1 :150%of lamps in permanent ❑Complies [FI6]1 fixtures are high efficacy lamps. ❑Does Not ❑Not Observable ❑Not Applicable 401.3 ;Compliance certificate posted. ❑Complies [F17]2 j❑Does Not ❑Not Observable ❑Not Applicable 303.3 I Manufacturer manuals for €❑Complies [FI18]3 mechanical and water heating ❑Does Not ;equipment have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact( 3) Project Title: 140707_Trust MerrimackCondos_BldgD_UnitsB-E-E.NAndover Report date: 09/09/14 Data filename: S:\Ebbeling_Ed\140707 Trust_MerrimackCondos_Bldg F_UnitsB-E- Page 9 of 9 E_NAndover\REScheck\140909 Trust Merrimac BldgD_UnitF3_54.rck 2009 HCC Energy Efficiency Certificate ,Insulation . Wall 15.00 Floor 38.00 Ceiling/Roof 38.00 Ductwork(unconditioned spaces): Window 0.29 Door 0.29 Heating System: Cooling System: Water Heater: Name: Date: Comments C31 c330 C37 WETLAM DVACTED ONl UM WrVM PTS, M � L T7 To TO � �4 SHOW MERM c34 �"` ,� � C C39 c36 001, i1.cy 481 ---6.5' � ,s c35 o o C40 C4 48.6 O Q J6 0 /,'�P ROPOSE BLDG-Dr PROPOSED ` SLOG Ow s v CERTIFIED PLOT PLAN w oTHER use vrcmm NO E&IMM SKM ARS 14M Of THE OPIUM, Ptr m Rw ym PR T. THE FtRRmnm AS smw mm HRCT ONE rmmo H TM PLM M NUt M K USM M QCT FF3CM QUER � r STRUCTURM of FOR L46MSCAptwj L 53, E XY som MOWRY,m TM CEAT?FMTIW IS PW-TRYAtiS€ERMNLL AND 13 FURTHER MC V1TH THE PRUVVM THAT THE D#MRNATMN SHOW Ma MR A=AtATELY FURNUM BY was,mr a THE OWER M TH U FOL 106D.03 td** FE3USI`DA` 'IOiN.AS—BUILT' ,. UIL I Gi OF* PuNERRIMIAC CON'DOM1N1UMS • ••• • - t*h'�..►t� 1 ROUTE 114 NORTH ANDOVER, MASS. PATMM PROJECT' ND NAND13 SCALE, 1''=4W DRAIN BYr PCG DAT•Et 2/7/1.4 CHECKED BYE SC 517+ ��~ REVISEDy/ 14 GF's 3 °I OVWV f 0 . VIP t 41 cp S°t •e rtJ � { p —J Massnlaltusetts•-isiepniii'vie d CA Pi4bl'!r safety i Board of Building Reg idaticnns-and Standards �.(YYkti�t7l S:�i3Y di `-+`^ •ate License:CS409350 r . � C• TIMOT"M BA 117 f �O BOX#12 i !South Grdtou mi 01 Expiration . Carnn%%i �8rn>cr 01/2412t{'IB II i I � Oda nt Treated ood tions plica ® Provides tested r W ment,FRX wood p I may be substituted for I ,ad and smoXeo ed to weather; ated by the L' w_')ns directly e P es design uilding ®wood combines 44 �,aombustibie in certain bon ormance FRX ble materials. Y �;uiring.ASTM D 28 of non-combusts co 0vood with the fire safety W .00 U- . Free of halogens j ?o� . Kiln dried after treatmentd a available d o ed,military Y � �¢ o•a �e . Paper wrapped, ® o`ags, . Issued ESR-1159 O � y Wo 'OKE DEVELOPMENT VVII � Fire Performance Ratings tunnel test � As determined in the ASTM E Smoke ` ,g of Flame pevelopment spread -- ,candard species ,t 15 est is extended _ 20 fto qualify as a ' � ern Pine m fire 20 south 15 25 dial.FRX Wood maintains Douglas Fir 45 ,eated 20 both those Hem-Fir ,r all species listed• 0 ;S than Western Red Cedar 20 w ,panying table for specificsPr,ue r r 0 igs by species. 20 0 •,� . FRT Wood must Southern Pine 1s 10 �r exterior use, Douglas Fir 20 o further ASTM E 84 anderg spruce "g00-inch rain which is conducted on testing, test,also referred to as the material that has beenaccelerated weathering ' assed by FRX®Wood. the ASTM D 2898 test."This testing protocol has been p TIONS applications permitted by a '� COMMON ApPLICA be used in exterior app , materials would transfer heat or allow I wood may atmospheres FRX®fire retardant treated cal,other m corrosive atmosp , public safety is critical, be installed, protection is I the codes where p stems cannot easily where fire p t read,sprinkler sy fires to spread,excessive maintenance of other materials,and I necessitate available. inadequate or not readily TYPICAL EXTERIOR USES • Storefronts and facades . \Nall coverings . Eaves,soffits and fascia . Construction staging . Roof coverings and horse stalls • Balconies . Agricultural buildingstanks • scaffolding and scaffold p ercial uses . Stairways ' • Decks . various other residential and co 4 open-air roof systems ` . canopies and awnings --------------• - —-- -------- - • • • --------- • • • • • FR-I: d�3I R � � ! �--� � ,� 1� a- i - � � � ,, 1 ' �� J� � _ __- _ - 1 1 r FRX8 Fire Retardant Treated Wood for Exterior Applications Invented to reduce flame spread and smoke development, FRX®wood provides tested fire protection for applications directly exposed to weather;it may be substituted for materials classified as non-combustible in certain building types designated by the . model building codes and requiring ASTM D 2898 conformance. FRXII wood combines the beauty and versatility of wood with the fire safety of non-combustible materials. • Complies with major model • Free of halogens _ building codes • Kiln dried after treatment •Tested, proven fire performance • Paper wrapped, military dye available • Effective for lumber, plywood, logs, . Issued ESR-1159 siding, LVL FLAME SPREAD AND SMOKE DEVELOPMENT Model building codes require a Fire Performance Ratings read rating of 25 or less and a smoke developed rating of As determined in the ASTM E 84 tunnel test 450 or less,when the standard Flame Smoke surface burning test is extended Species Spread Development to 30 minutes to qualify as a Class A material. FRX°fire Southern Pine 1s 20 retardant treated wood maintains Douglas Fir 15 0 ratings less than both those Hem-Fir zo 25 levels for all species listed.See western Red Cedar 20 45 accompanying table for specific Spruce 20 0 ratings by species. PLYWOOD For exterior use,FRT wood must Southern Pine zo o undergo further ASTM E 84 Douglas Fir 15 0 testing,which is conducted on material that has been through Spruce 20 10 the ASTM D 2898 accelerated weathering test, also referred to as the"800-inch rain test"This testing protocol has been passed by FRX®wood. COMMON APPLICATIONS FRX®fire retardant treated wood may be used in exterior applications permitted by m the codes where public safety is critical,other materials would transfer heat or allow fires to spread,sprinkler systems cannot easily be installed,corrosive atmospheres necessitate excessive maintenance of other materials,and where fire protection is inadequate or not readily available. rJF^ TYPICAL EXTERIOR USES • Wall coverings • Storefronts and facades • Roof coverings • Eaves,soffits and fascia • Balconies • Construction staging • Stairways • Agricultural buildings and horse stalls • Decks • Scaffolding and scaffold planks • Open-air roof systems • Various other residential and commercial uses • Canopies and awnings STRENGTH FRX®wood has been tested in accordance with ASTM D 143 and MIL-L-19140E. Following are the design value adjustments. Strength Design Factors for FRX°Fire Retardant Treated Lumber Compared to Untreated Lumber Allowance Total Sheathing Load(psf) Applicable at Ambient Temperatures Up to 80°F* for FRX®Plywood Tested Species Plywood Span(inches) Thickness Plywood Southern Douglas g Ratin Pine Fir (inch) 12 16 19.2 24 30 32 36 40 48 Compression Parallel 1.00 1.00 5/16 20/0 185 104 67 47 Horizontal Shear 0.91 1.00 3/8 24/0 280 161 103 71 28 Tension Parallel 0.78 0.88 15/32,1/2 32/16 409 231 145 102 65 57 Bending: Modulus of Elasticity,E 1.00 0.96 19/32,5/8 40/20 641 361 231 160 103 88 57 46 Extreme Fiber Stress,Fb 1.00 1.00 23/32,3/4 48/24 805 453 290 202 128 114 71 61 41 *Lonza Wood Protection does not recommend the use ofTable based on Structural 1,exterior-grade plywood.Fastener size and spacing must be as FRX wood in high temperature interior applications.Dricon0 required in the code for untreated plywood of the same thickness. FRT wood should be used in these situations.Contact Lonza Wood Protection or visit us online at www.dricon.com for more information. APPEARANCE The treatment has little effect on the color of lumber.Deposits • • • • of FRX®fire retardant solution may appear on the surface of wood or exude from the edges of plywood during drying. This is a result of injection of adequate chemical to achieve desired fire protection,and is considered normal.On most species, discoloration is barely noticeable. Marks made by stickers, used to separate the layers of lumber during the kiln drying following treatment,will be -• -., - ,.. .• _ noticeable on lumber. For structural use,this is not usually objectionable.FRX®exterior FRT wood can be special ordered with one face free of sticker marks.Slight irregular water ••• • ' • marks may show on such material. ••• •' -• • ••• • - •-• The pressure treatment and subsequent drying may result in a slight waviness in plywood;for normal applications this ,, _ • is not a problem as the plywood can be straightened when •• _ nailing. TIPS ON USE ' ' "' '" ' 1. FRX®wood should not be installed where it will be o exposed to high interior temperatures, or in contact with the ground. 2. When painting or staining,the paint or stain manufacturer's •• . . . ..-. •. -. recommendations should be followed.As with untreated . - • - •-. . . lumber, the surface should be clean and dry. See • • •- www.frxwood.com for more details. 3. The same common sense precautions should be taken when handling FRX®wood as with untreated wood or other building materials. Dust masks and eye protection _ devices are recommended to avoid possible irritation from sawdust and wood chips. Gloves will help avoid splinters.Hands should be washed after doing construction work. ©2012 Arch Wood Protection, Inc.,a Lonza company FRX-2031-112 f +Z •X 4 I i i { 1.631 TU4X2.5 4 5 1.6 2 ' N I` I 3 i I i 1 . I 1 1.9 I ALL TUBES ARE 1 / 8 " THICK � 1.1 I KL MA cn=KL MA, o=KANAYO LALA, ou, LAU email=KANAYOLALA@GMAIL. re KL COM, c=US 2013.02.22 16:55:03 -05'00" Results for LC 3,ALL Z-moment Reaction units are k and k-ft KANAYO LALA- PE ` SK-2 - - -- -. - — - --i KL BALCONY BRACKET Feb 22, 2013 at 4:5-1--P.-M.. f 13000 BRACKET MEBER SIZES I METAL BRACKET MERRIMACK-... ' I -.6k/ft fit `Ct '•" ` i 2.8 ... ,t'..". „J 1 0 Loads:LC 3,ALL Results for LC 3,ALL Z-moment Reaction units are k and k-ft KANAYO LALA- PE SK- 1 KL HIP ROOF PORCH Feb 22, 2013 at 12:10 PM 12115 BALCONY BRACKET 4'6" LONG@8' SPACING METAL BRACKET MERRIMACK.r... 00RTH Town of t EAndover IF 0 {` 0 I- AawwNo. ver, Mass, il A_ COC./IC Nl WICK 7�A�4ArE0 S U BOARD OF HEALTH Food/Kitchen PERMIT T LD Septic System THIS CERTIFIES THAT BU LDING,INSPE TOR has permission to erect buildings on ......... GESS . wi FF undation .Rough L i V/-'�/77 L.- to be occupied as ......... ...1:�....C t� y ....... .... 0 .... ................................................................ Chi ne provided that the person accepting this permit shall in every respect conform to the terms of the application ein, on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection, Alteration and Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR Rough �'/I��i 1 1 k VIOLATION of the Zoning or Building Regulations Voids this Permit. Final ,ykb � l PERMIT EXPIRES IN 6 MONTHS ELECTRICAL INSPECTOR UNLESS CONSTRUCTION S TS Service ..................... ..... . . ....... ... .. !Z rt...,.................. BUILDING INSPECTOR GAS INSPECTOR Occupancy Permit Required to Occupy Building Ro . %d� Display in a Conspicuous Place on the Premises — Do Not Remove Final '5/' 4 (1 No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. Burner , Street No. 7i - 1L� C* NORT{y ttED < q<y { 6i 0 APPLICATION FOR CERTIFICATE OF OCCUPANCYANSPECTION "TED CHy BUILDING PERMIT # 0 —1 S �SSAUS EK 3q ADDRESS/LOCATION OF PROPERTY: 3 , 5Y OG.ss 0+ Map O Parcel Lot Number SUBDIVISION: Mef(-% MCA.C_IC. er,2 �S DATE REQUESTED FILED/READY FOR INSPECTION: CLOSING DATE ON PROPERTY: FIVE(5)DAYS NOTICE PRIOR TO CLOSING DATE IS REQUIRED ALL WORK AND SIGN-OFFS MUST BE COMPLETED WITHIN THIS TIME FRAME. A REINSPECTION FEE OF TWENTY DOLLARS ($20.00) WILL BE CHARGED IF THE STRUCTURE DOES NOT MEET ALL APPLICABLE CODES. ' APPLICANT SIG TURE Permit Issued to: (ry C� r' Address: Sk SnUom / ROUTING /TOWN ENGINEER, SITE PLAN—DRIVE-WAY REVIEW ❑ CONSERVATION [q/ PLANNING ❑ "DPW-WATER METER �`rt OWER CONNECTION C� DPW MUST INDICATE THAT THE WATER METER HAS BEEN INSTALLED PRIOR TO SUBMITTAL OF THE OCCUPANCY/INSPECTION REQUEST `bPW SIGNATURE File:Application for OC form revised Jan 2007/2011 c3i o c33c C37 WETLM= Df%CTO ars STM KTWMK PM UL C48 & T7 'M tom ►` w Rug Di SPf= OF eft,4 c34 'eso" C C39 001* iVy 48.2' —6.9' + is c35 s• o a C4U C¢ O o 11,0 4 °• 4 r /..PROPOSED l SLOG M� �.I PROPOSED s CERTIFIED PLOT PLAN mun4mUSX nag= a �. NAW nm Tilly �, ne momnm a � mo i =CnWM MPUM LW Tin Puw M IIT m K USED mcm amm Amcn 9F Omni tTvjcnms, m i t awwo G uxrm w oam mr rr*,Asxw,0 Gum Tilt couu C1inm is $ -T Ql*Axr, Om m ruwn4m MV' vnw Tie � U AT Tie IFFCvIRTi m S a*% ms Xw f;TY Fly >m 1�►�t,� m ws FMloarl•Ib FE]UNIMATT[IN. -BUILT.BUILDI C T" Amm G MERRIMAC CONDOMINIUMS ROUTE 114, NORTH ANDOVER, MASS+ PAM= PROJECT NSD NAND1.3 SCALE1 11=40" GAA^ti--ANo =51 DRAWN RYt PCG n y 2/7/14 p7/ `pfd '¢!�Sp� i CHECKED DY@ SC SHT+ 1 '►krvYY��" REV'ISEIA Qf"1 1 50 Washington Street Suite 3000 Westborough,MA 01581 t 508.836.9500 Conser ation f 508.870.5975 Services Group www.csgrp.com IECC 2009 & MA Stretch Energy Code Duct Tightness Verification Pass ail Date: June 23`d,2015 Permit No.: Street Address:54 Compass Point North Andover, MA 01845 Total conditioned floor area:2,175 Square Feet Source of Area Calculation: Builder HERS Rater: Nicholas Abreu Certification Number: 8368122 Signature: — Builder: Tim Barlow Builder Contact: TB Building HVAC Contractor: 1&J Heating and Air Conditioning 2009 IECC-New Construction Post-construction test ® Total Leakage–12 cfm/100 ft2 maximum allowed ❑ Leakage to outdoors–8 cfm/100 ft2 maximum allowed Testing result: 9.1 cfm/100 ft2 Rough-in test Total leakage Air Handler Installed? ❑ Yes–6 cfm/100 ft2 maximum allowed. ❑ No–4 cfm/100 ft2 maximum allowed Testing result: cfm/100 ft2 MA Stretch Energy Code–401.3 Prescriptive Option for Residential Additions and 401.5 Prescriptive Option for Alterations,Renovations or Repairs Applies to all systems except those in which the air handler and all ducts are located within conditioned space ❑ Leakage to outdoors-4 dm/100 ft2 maximum allowed Testing result: cfm/100 ft2 Results apply to the system as tested on the date above.Compliance is void if any changes are made to tb@ du@t§Y§t@fR: Final Construction Control Document To be submitted at completion of construction by a h ' Registered Design Professional for work per the 8`"edition of the V Massachusetts State Building Code, 780 CMR, Section 107 Project Title: MERRIMACK TOWNHOMES Date: 4/29/15 Permit No.-F-39,40,41-15 Property Address: 54, 56&58 COMPASS PONT, NORTH ANDOVER, MA Project: Check one or both as applicable: X New construction ❑ Existing Construction Project description: Wood framed, fire sprinkled,three story town homes in a row of three in the building named "F" with u/g_gas, electric,water and sewer services. I KANAYO LALA MA Registration Number: 33710-C Expiration date: JUNE 30, 16 ,am a registered design professional, and I have prepared or directly supervised the preparation of all design plans, computations and specifications concerning: [ ] Architectural [ ] Structural [ ] Mechanical [ ] Fire Protection [ ] Electrical [X] Other: ALL DESCIPLINES for the above named project. I,or my designee,have performed the necessary professional services and was present at the construction site on a regular and periodic basis.To the best of my knowledge,information,and belief the work proceeded in accordance with the requirements of 780 CMR and the design documents approved as part of the building permit and that I or my designee: 1. Have reviewed,for conformance to this code and the design concept,shop drawings,samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Have performed the duties for registered design professionals in 780 CMR Chapter 17,as applicable. 3. Have been present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work was performed in a manner consistent with the construction documents and this code. Nothing in this document relieves the contractor of its responsibility regarding the provisions of 780 CMR 107. Enter in the space to the right a"wet"or `w OF electronic signature and seal: , K uu H No.33710-C fSS10 4l Phone number: 978-337-5252 Email: kanayolala@gmail.com Building Official Use Only Building Official Name: Permit No.: Date: Version 06 11 2013 I Enter construction cost for fee cal - North Andover Fee Calculation Construction Cost $ 265,375.00 m $ - $ 3,184.50 Plumbing Fee $ 398.06 Gas Fee 100 comm. $ 100.00 Electrical Fee $ 398.06 Total fees collected $ 4,080.63 54 Compass Point 039-15 on 7/11/2014 3 Bedroom Condo