Loading...
HomeMy WebLinkAboutBuilding Permit #756 - 54 Harold Street 6/19/2008BUILDING PERMIT TOWN OF NORTH ANDOVER APPLICATION FOR PLAN EXAMINATION Permit NO: Date Received Date Issued: I IMPORTANT: Applicant must complete all items on this page I LOCATION 66o IA`"a✓o k8 f ". 00, A"1Ac.VQ4&v'1 AJ A 01ca—q—r Print PROPERTY OWNER A( ✓(� C. tv't5i�iy' %-t,l,✓tin41 Print MAP NO: /D PARCEL: ,6 ZONING DISTRICT: Historic District yes no Machine Shop Villaae ves no TYPE OF IMPROVEMENT PROPOSED USE Reside Non- Residential New Building eme famiI Addition Two or more family Industrial A eration No. of units: Commercial Repair, replacement Assessory Bldg Others: Demolition Other Septic Well Floodplain Wetlands Watershed District Water/Sewer . DESCRIPTION OF 1(VORK TO BE PREFORMED: �,�c.tyuut' �zl 13' Ted d-arw►�s c7-►� �x �s� HQ ra 5\ I1ov Identification Please Type or Print Clearly) OWNER: Name: A(e\ Cla✓tsSy �Nvvtct✓1 Phone: R76 68V—A04—i Address: 1-410 Hzx --v t J S{: No. MA G7 l8 4S CONTRACTOR Name:GcA A%csvt-:,� . Phone: Z 8t X13-1 S$caS''' Address: 1 t c o t 8o i Supervisor's Construction License: 07 C( � &I Exp. Date: D(a 0 — Horne Improvement License: \ 23 01 Exp. Date: co ARCHITECT/ENGINEER Tv +.2^, Phone: 1 Ibt 7316 312;3 Address: Ito O 196 ( Reg. No. A :�'Zt -2, FEE SCHEDULE: BULDING PERMIT: $12.00 PER $1000.00 OF THE TOTAL ESTIMATED COST BASED ON $125.00 PER S.F. Total Project Cost: $ 54. 2418. ° O FEE: $ 6�Q Check No.: -1166--1 Receipt No.:�� NOTE: Persons contracting with unregistered contractors do not have access to the gua my fund _o- ___._ - - Signature , ofrrt/Owner-��..� Signature of contrac#or Plans Submitted Plans Waived Certified Plot Plan Stamped Plans GE DISPOSAL Public Sewer Tanning/Massage/Body Art Swimming Pools Tobacco Sales Food Packaging/Sales Private (septic tank, etc. Permanent Dumpster on Site THE FOLLOWING SECTIONS FOR OFFICE USE ONLY INTERDEPARTMENTAL SIGN OFF - U FORM DATE REJECTED DATE APPROVED PLANNING & DEVELOPMENT COMMENTS DATE REJECTED DATE APPROVED CONSERVATION COMMENTS i� DATE REJECTED DATE APPROVED HEALTH COMMENTS Zoning Board of Appeals: Variance, Petition No: Zoning Decision/receipt submitted yes Planning Board Decision: Comments Conservation Decision: -Comments Water & Sewer Connection/Signature & Date Driveway Permit Located at 384 Osgood Street FIRE DEPARTMENT - Temp Dumpster on site yes no Located at 124 Main Street Fire Department signature/date COMMENTS Dimension Number of Stories: Total square feet of floor area, based on Exterior dimensions. Total land area, sq. ft.: ELECTRICAL: Movement of Meter location, mast or service drop requires approval of Electrical Inspector Yes No DANGER ZONE LITERATURE: Yes MGL Chapter 166 Section 21A—F and G min.$100-$1000 fine NOTES and DATA — (For department use ❑ Notified for pickup - Date Doc.Building Permit Revised 2007 No Building Department The following is a list of the required forms to be filled out for the appropriate permit to be obtained. Roofing, Siding, Interior Rehabilitation Permits ❑ Building Permit Application ❑ Workers Comp Affidavit o Photo Copy Of H.I.C. And/Or C.S.L. Licenses ❑ Copy of Contract ❑ Floor Plan Or Proposed Interior Work ❑ Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit Addition Or Decks ❑ Building Permit Application ❑ Certified Surveyed Plot Plan ❑ Workers Comp Affidavit ❑ Photo Copy of H.I.C. And C.S.L. Licenses ❑ Copy Of Contract ❑ Floor/Crossection/Elevation Plan Of Proposed Work With Sprinkler Plan And Hydraulic Calculations (If Applicable) ❑ Mass check Energy Compliance Report (If Applicable) ❑ Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit New Construction (Single and Two Family) ❑ Building Permit Application ❑ Certified Proposed Plot Plan ❑ Photo of H.I.C. And C.S.L. Licenses ❑ Workers Comp Affidavit ❑ Two Sets of Building Plans (One To Be Returned) to Include Sprinkler Plan And Hydraulic Calculations (If Applicable) ❑ Copy of Contract ❑ Mass check Energy Compliance Report ❑ Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit In all cases if a variance or special permit was required the Town Clerks office must stamp the decision from the Board of Appeals that the appeal period is over. The applicant must then get this recorded at the Registry of Deeds. One copy and proof of recording must be submitted with the building application Doc: INSPECTIONAL SERVICES DEPARTMENT:BPFORM07 Revised 2.2007 Location r%ar a 1-t No. 7S-6 Date C - off' TOWN OF NORTH ANDOVER e Certificate of Occupancy $ Building/Frame Permit Fee $ S� Foundation Permit Fee $ Other Permit Fee $ TOTAL $ Check # G/ 2 r r� i t8 Building Inspector w w O O FM4 W cz Fj o co C O o � C y ' � C C.3 u •dam d C O O C _t 0 �. co E a m y d: E C w e m C ' y CLA :mm o CO, CM h � � m H A ca mo Z 1 \' cm p C V y O c2 '; Z ,r�C�o � a Q C y m C x m :m�3 p, O ~ w H m $ ~ W C o Ow=..•OZ LL 16 C «. H 'd= O C 7 +•' LU E ca 0 C3 cm C.3 CD cm N_ n oCD � o� x R m ` h = f- z 0aOm 5 cm F. 91 .m a) O CD L O s ZCD O H o c CD cm i O co o_ h O O .E m m � H= CL f•+ 3.0 � 0 0 e_vv o a cmQ c o .0.0 � ev cc d O � c Z Q V y O C c m H 0 W IO LLI vI N It W 19 W U) .� �.cn o w ' a coo p U � ca�' or. C-0 w a w U w O � p' x °�° w w � W �, a W .� aG chi w x O C7 o00 O C4 G w z W fx v cc ., cn v o cn o co C O o � C y ' � C C.3 u •dam d C O O C _t 0 �. co E a m y d: E C w e m C ' y CLA :mm o CO, CM h � � m H A ca mo Z 1 \' cm p C V y O c2 '; Z ,r�C�o � a Q C y m C x m :m�3 p, O ~ w H m $ ~ W C o Ow=..•OZ LL 16 C «. H 'd= O C 7 +•' LU E ca 0 C3 cm C.3 CD cm N_ n oCD � o� x R m ` h = f- z 0aOm 5 cm F. 91 .m a) O CD L O s ZCD O H o c CD cm i O co o_ h O O .E m m � H= CL f•+ 3.0 � 0 0 e_vv o a cmQ c o .0.0 � ev cc d O � c Z Q V y O C c m H 0 W IO LLI vI N It W 19 W U) RENOVATION SOLUTIONS Date: May 30, 2008 REVISED ANDOVER RENO" kTION SOLUTIONS, INC. 110 Winn Street, Suite Woburn, Massachusetts 01801 781937-8805 FAX 781932-1174 04-3452338 MA Home Improvement Contractor 128016 MA Construction Supervisors License 079181 Name: Ahren and Chrissy Lippman Project Address: 56 Harold Street, North Andover, MA 01845 Home Phone: 978 688-4047 Mailing Address: Same e-mail: alippman@statestreet.com Day Phone: Ahren Work 617 664-1829 Ahren Cell 617 571-3841 Work To Be Performed under this Agreement: 1. We will furnish and install in a workmanlike manner the remodeling project according to the conceptual plans dated May 30, 2008, scope of work attached, and the terms and conditions made part of this agreement. 2. This agreement is subject to Addendum A made part of this agreement. 3. Includes a reduction in the price listed below in the amount of $1295.00 for the original design fee already paid by the purchaser. 4. The final price listed below will change based on the final scope of work determined at the pre -construction meeting and will be adjusted by Change Order #1 outlining additions and deletions to this agreement. Anticipated Construction Schedule at time this agreement is signed: Approximate Start Date of Work: 07-15-08 Approximate Substantial Completion Date: 11-30-08 The above schedule are approximate dates for overall planing purposes only. We can not be held responsible, for circumstances arising during the course of construction beyond our control. Price: $54,298.00 Payment Payments are to be made as per the payment schedule on page 7 of this Schedule: agreement. The parties agree to the attached schedule. This agreement supersedes all conversations, statements, and agreements expressed or implied between the parties, their agents and representatives. Do not sign this Agreement if there are any DianK spices. - _✓---- (p -�f'� 0 r• IN Willid'm C. Penny, President. Date L 7-0y Date A—ci -or Date Page I of 6 Andover Renovation Solutions, Inc Addendum "A" To Purchase Agreement - Dated May 30, 2008 1. Financing Contingency In order to assist or help finance the work set forth in the work specifications of this purchase agreement, you shall apply for a conventional bank or other institutional loan of $ payable in no less than 30 years at prevailing market rates. If despite your diligent and good faith efforts a commitment for such loan cannot be obtained on or before June 30, 2008, you may terminate this agreement by written notice to Andover Renovation Solutions, Inc., said written notice shall contain written evidence to us, as to your inability to obtain financing, whereupon any and all obligations of the parties hereto shall cease and this agreement shall be null and void without recourse to the parties hereto. In no event will you be deemed to have used diligent efforts to obtain such commitment unless you submit a completed loan application conforming to the foregoing position on or before June 30, 2008, to a conventional bank or other financial institution which is presently in the business and practice of making residential mortgage loans. Should you fail to notify Andover Renovation Solutions, Inc. in writing on or before June 30, 2008, TIME BEING OF THE ESSENCE of your inability to obtain such financing with written evidence acceptable to us, then it shall be conclusively presumed that you have obtained satisfactory financing and this contingency shall lapse, and you shall be bound to perform your obligations under this agreement. In the event financing is not obtained by client as outlined above, any monies received will be returned within 30 days less any out of pocket expenses incurred by Andover Renovation Solutions, Inc. 2. References Contingency You hereby acknowledge receipt of a list of references from the Andover Renovation Solutions, Inc. You may on or before June 11, 2008, check the references furnished by us. You shall have the option of withdrawing from this agreement by written notice to Andover Renovation Solutions, Inc. on or before June 11, 2008, TIME BEING OF THE ESSENCE. Should you fail to notify us in writing on or before June 11, 2008, your wish or desire to withdraw from this agreement then it shall be conclusively presumed that you have checked the references provided by us and are satisfied with our references and qualifications and this contingency will lapse, and you shall be bound to perform your obligations under this agreement. Page 2 of 6 Scope of Work - May or -May 28, 2008 Lippman Master Bedroom Project 1 Construct (2) shed dormers as per conceptual drawings dated May 28, 2008 and labeled "Floor Plans -Option" including removal of roof and roof structure, 2x10 rafters, '/2" CDX plywood wall and roof sheathing, 2x4 wall construction, GAF asphalt fiberglass three tab roofing to match existing, cement siding to closely match existing asbestos siding, #2 primed pine exterior trim boards, windows and doors as specified below, R-13 fiberglass wall insulation, R- 30 fiberglass ceiling insulation, blueboard and skim coat plaster, aluminum gutters and downspouts, 2 Furnish and install (5) Harvey Vicon vinyl windows with low E glass, full insect screens and grilles on top sash only. (3)28310, (2)210410 Install tempered sashes in stair well windows and tub window. 3 Install 3/4" plywood sub -floor over existing plank flooring. 4 Furnish and install (1) Jeld Wen 1-3/8" Cambridge molded two panel solid core interior door with Schlage Plymouth polished brass passage set. Furnish and install (1) Jeld Wen 5 foot hollow core Cambridge bi-fold closet door. 5 Construct (2) closets in existing bedroom as per plan with clothes pole and shelf in each and 1x5 primed casing with 5/4" head casing with crown. Patch existing clear 1x6 baseboard with cap molding. Plaster patch. walls as necessary. Remove (2) existing closets as per plan and patch interior walls and baseboards. 6 Install electrical to include relocation of all wiring in disturbed walls and ceilings and installation of (12) new outlets, (6) client supplied light fixtures, (6) hard wired smoke detectors, and (1) bath fan. 7 Does not include interior or exterior paint, plumbing, tile, interior finish on new bedroom side or reconstruction of existing stairs. Does not include client supplied surface mounted light fixtures or carpet. Includes permit application, permit fees and all required construction drawings. 9 Provide certified plot plan. 10 Remove all construction debris in supplied containers. Page 3 of 6 Farms and r"loons: ...................................................................................................................................... 1. Parties: "You" refers to the buyer or buyers. "We" or "Us" refers to the seller, Andover Renovation Solutions, Inc. 2. Access: You will permit us to go into the premises. the premises includes the land and the buildings. You will get any consent needed for us to go onto any other premises in order to do the job. You are responsible and hold us harmless and accept all risks for access through adjacent properties. if we are not allowed to go onto the premises and are prevented from completing the work, then we have no further duty to perform this contract. 3. Insurance: We and all our subcontractors agree to carry the necessary Workmans' Compensation Insurance and Public Liability Insurance as required by law. They cover the work to be performed under this agreement. 4. Warranties: We warranty all materials and workmanship for a period of one (1) year from date of substantial completion on all work and materials supplied by us. This warranty does not cover damages beyond our control such as misuse or failure to follow maintenance instructions or Acts of God. If a replacement product is unavailable will we provide a substitute of equal value. You may not withhold any portion of the final payment for guaranteed performance under this warranty. No service under this warranty is available if payments have not been made under this agreement. The only remedies for breach of warranty are stated in this paragraph. It is understood that we will not be liable for incidental, special or consequential damages in any way connected with the products or their installation whether for breach of warranty express or implied, negligence or other reason. The limitation of damages under this warranty are for repair, replacement or abatement only. 5. Changes and Alterations: No additional work will be performed without the prior written authorization by you. Any such authorization will be done on a written Change Order form approved by both parties. Corrections of existing building code violations not specified in the project description, or hidden structural, electrical or plumbing defects will be an addition to this Agreement and paid by you. Any changes requested by inspecting Public Authorities not covered in the Project Description will be billed to you as additional work. You agree that the duration of work and the scheduled date of completion may differ from the date as indicated on page one, because of changes, alterations, hidden conditions, inspectional delays, etc. which are unavoidable by us and shall not be considered to be a violation of this agreement. Change orders are paid at time of approval and prior to such work. 6. Survey: You are solely responsible for the location of all lot lines and shall provide at your own cost a survey showing buildings and property lines unless a certified plot plan is included in the attached scope of work. 7. Matching Existing: Where materials are to be matched, we will make every effort to do so, using standard materials, but we cannot guarantee a perfect match. We are not responsible for the existing conditions of the structure with regard to the level and plumb of walls, ceilings and floors and work to be done to existing conditions will be done in a workmanlike manner without re -plumbing existing conditions unless specified in the Project Description. 8. Landscaping and Ledge: This agreement does not cover the blasting or removal of ledge during excavation and will be billed separately to you. We will bring the grade, back to a rough grade condition after excavation, which does not include loam, seed or sod. We are not responsible for damages to landscaping or grounds due to the use of vehicles or heavy equipment. 9. Payment Schedule: Payments shall be made by you as per the attached Payment Schedule. We have the right to stop work if payments are not made to us when due. Overdue payments will include a finance charge of 18 percent per year. We shall pay all invoices authorized by us arising out of the construction and will hold you harmless against any liens for labor or material filed against the property provided you have made all payments due us under the payment schedule. 10. Owner Supplied Services: You agree to provide electricity, water, toilet and telephone as may be required by us to perform the work under this Agreement. 11. Advertising: You grant us the right to display a job sign at the property and take photographs of our work for the use in our advertising. 12. Complete Agreement: This contract is the entire agreement, and it is agreed by both parties that the entire understanding is contained in this written contract between you and us. It is further agreed that any subsequent changes to this agreement must be in writing and signed by the parties. No oral agreements not specifically stated in this agreement will have any force or effect. You are advised not to sign this agreement unless all blank sections have been filled in or marked as void, deleted or not applicable, and until all exhibits and related documents that are incorporated herein are attached. Page 4 of 6 I 3. Subcontractors: We have tb- 'ght to subcontract any percentage of the work v ' , performed under this agreement. You will not during the coursk the project hire any of our designated subco►. tors for other or additional work without our written approval. You may hire your own subcontractors to perform selected work at our approval during the course of our construction process. You are responsible for their supervision and their clean-up of the work site. You must have them provide us with insurance certificates prior to starting their work, if they are working during the course of our construction period. We are not responsible for delays caused by your subcontractors. 14. Cancellation: You may cancel this agreement within three business days as required by law ifthis agreement is signed outside our place of business. We retain the same right of cancellation. Any deposit received from you will be returned. See attached notice of cancellation (if signed by the parties at a place other than our place of business) for an explanation of this right. 15. Registration: All home improvement contractors and subcontractors engaged in home improvement contracting,. unless specifically exempt from registration by provisions of Chapter 142A of the general laws, must be registered with the Commonwealth of Massachusetts. Inquires about registration and status should be made to the Director, Home Improvement Contract Registration, One Ashburton Place, Room 1301, Boston, MA 02108. 16. Permits: We agree to obtain as your agent the building, plumbing, and electrical permits necessary to complete the scope of work under this agreement. We shall not be held responsible for delays in the work described in this agreement caused by regulatory, permit granting or inspectional agencies, or authorities. Under Chapter 142A, homeowners that obtain their own construction related permits or contract with unregistered contractors will be excluded from the guaranty fund. 17. Copy of Agreement: This agreement in governed by the Laws of Massachusetts. It must be executed in duplicate, and an original signed copy will be given to you at the time of execution. No work under this agreement shall begin prior to the signing of this agreement and transmittal to you. 18. Arbitration: The contractor and the homeowner mutually agree in advance that in the event of a dispute concerning this agreement, the parties shall submit such dispute to a private arbitration service which has been approved by the Secretary of the Executive Office of Consumer Affairs and Business Regulations as provided in MGL c. 142A, and the decision of the arbitrator will be final. In the event of a dispute, and we have to retain an attorney to collect monies due us, and we prevail, you will be responsible for all attorney fees. 19. Cleaning: We will keep the job site broom clean. At the end of the job we will broom clean all disturbed areas. 21. Unknown Conditions: We will advise you in writing of any unknown conditions discovered during the course of construction; ie. moisture, mold/mildew, rotted wood, insect damage, or any existing structural damage. We will provide a separate cost to you for those repairs. 22. Living at the House During Construction: It is recommended by us that you vacate the house during construction, however if you decide to live at the house we are not responsible for any health related problems due to dust, or adverse moisture conditions. You are responsible to keep children and pets away from the construction site. 23. Quality and Workmanship Standard: Quality and workmanship standard for this contract are defined by the National Association of Home Builders, Residential Construction Performance Guidelines for Professional Builders & Remodelers, 2 n Edition, ISBN 0-86718-495-7. In the event of a dispute these standards will be used. 20. Approval of these terms and conditions is indicated by your signature on the first page of this agreement Page 5 of 6 Andover Renovation Solu s, Inc. Payment Schedule May 30, 2008 Name: Lippman Project Address: 56 Harold Street, North Andover, MA 01845 Phone: 978 688-4047 Payment Description Percent of Total I Amount Original Order Amount____ 55,593.00 Design Fee Paid ! $ $ (1,295.00) 0.00 0.00 Revised Contract Amountm__._ $ 100.00% T$ 0.00 I 54,298.00 With Order Deposit (Due At Placement of Order) _b(� _ 5.00% $ 2,714.90 A � vev► .._.�-. 1..-_ �I .._._71LS ._ _63-x- Materials Deposit I 30.00%. ( $ 16,289.40 Due at Preconstruction Meeting) At completion of exterior frame —~ At rough inspections 20.00% i $ 15.00% $ 10,859.60 8,144.70 At blueboard and plaster At installation of interior doors _ 10.00% $ 10.00% $ 5,429.80 5,429.80 i__ __. ________.... _ _ _. _ _ Substantial completion _ ° 8.00% $ 4,343.84 Completion of punch list_ 2.00% ! $ 1,085.96 ---- i Definitions: Substantial Completion is obtained when all areas of the addition/renovations are functional and habitable. Does not include any town inspections. Punch List Items: Material or weather dependent items that cannot be completed until received or done until weather permits. Punch list payment amount held by client should not exceed one and one half times cost of items not completed. Page 6 of 6 The Commonwealth of Massachusetts I?epartmenI of Industrial Accidents Office of Investigations 600 Washington Street Boston, MA 02111 www.mass:gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): Andover Renovation SOlutlons i t✓`G 110 Winn Street Address: Woburn, MA 01801 City/State/Zip: Phone #: -7131 OLS-1 6009 Are you an employer? Check the -appropriate box: 1 JA I am a employer with 4. ❑ I am a general contractor and I employees (full and/or part-time).* have hired the sub -contractors 2. ❑ I am a sole proprietor or partner- listed on the attached sheet I ship and have no employees working for me in any capacity. [No workers'. comp. insurance required.] 3. ❑ I am a homeowner doing all.work myself. [No workers' comp. insurance required.] t These sub -contractors have - workers' comp. insurance. ❑ We are a corporation and its officers have. exercised their Tight of exemption per MGL c. 152, § 1(4), and we have no employees. [No workers' comp. insurance required.] Type of project (required): 6. ❑ New construction 7. ❑ Remodeling 8. ❑ Demolition 9. ❑ Building addition 10.❑ Electrical repairs or additions 11.❑ Plumbing repairs or- additions 12.0 Roof repairs 13.0 Other *Any applicant that checks box # 1-mitst also fill out the section below showing their workers' compensation policy information # Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit.a new affidavit indicating such. tContractors that check this box must attached an additional sheet showing the name of the sub -contractors and their workers' comp. policy information. I ant an employer that is providing workers'rompensation insurance for my employees. Below is the.policy and job site information. Insurance Company Name: L i 6 ey �-A. lk4 a Policy # or Self -ins. Lica #: (/�(,, ' ?l' rj - 33j 1 1 Q--00 Z'? Expiration Date: �?i3 o$ Job Site Address: 56 t -'a., -D I d AL%. A Y%OqP., City/state/zip: MA D 19E -S Attach a copy of the workers' compensation policy declaration page (showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to $1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of.up to $250.00 a day against -the violator:- Be advised that a copy of this statement maybe forwarded to the Office of Investigations of the DIA.for insluance coverag.. verification. I do herebytettify under L and penalties of pe)jury that the information provided above is true and correct - 0 Oe orrect_ Phone #: -715( 1131 VIVO s OOe Official use only. Do not write in this area, to be completed by city or town official. City or Torn: Permit/License # Issuing Authority (circle one): 1. 1oard of Health 2. Building Department 3. City/Town.Clerk 4. Electrical Inspector 5. Plumbing Inspector '6. Other Contact Person: Phone #: Information and Instructions Massachusetts General Laws chapter 152 requires all employers to provide workers' compensation for their employees. Pursuant to this statute, an employee is defined as "...every person in the service of another under any contract of hire, express or implied, oral or written." An employer is defined as "an individual, partnership, association, corporation or other legal entity, or any two or more of the foregoing engaged in a joint enterprise, and including the legal representatives of a deceased employer, or the receiver or trustee of an individual, partnership, association or other legal. entity, employing employees. However the owner of a dwelling house having not more than three apartments and who resides therein, or the occupant of the dwelling house of another who employs persons to do maintenance, construction or repair work on such dwelling house or on the grounds or building appurtenant thereto shall not because of such employmentbe deemed to be an employer." MGL chapter 152, §25C(6)'also states that "every state or local licensing agency shall withhold the issuance or renewal of a license or permit to operate a business or to construct buildings in the commonwealth for any" applicant who has not produced acceptable evidence -of compliance with the insurance coverage required." Additionally, MGL chapter 152, §25C(7) states "Neither the commonwealth nor any of its political subdivisions shall enter into any contract for the performance of public work until acceptable evidence of compliance with the insurance requirements of this chapter have been presented to the contracting authority." Applicants Please fill out the workers' compensation affidavit completely, by checking the boxes that apply to your situation and, if necessary, supply sub-contractor(s) name(s), address(es) and phone number(s) along with their certificate(s) of insurance. Limited Liability Companies (LLC) or. Limited Liability Partnerships (LLP) with no employees other than the members or partners, are not required to carry workers' compensation insurance. If an LLC or LLP does have employees, a policy is required.. Be advised- that this affidavit may be submitted to the Department of. Industrial Accidents for confirmation of insurance coverage. Also be sure to sign and date the affidavit. The affidavit should be returned to the city or.town that the application for.the permit or license is being requested, not the Department of Industrial Accidents. Should you have any questions regarding the law or if you are required to obtain a workers' compensation policy, please call the Department at the number listed below. Self-insured companies should enter their self-insurance license number on the appropriate line. City or Town Officials Please be sure that the affidavit is complete and printed legibly. The Department has provided a space at the bottom of the affidavit for you to fill out in the event the Office of Investigations has to contact you regarding the applicant Please be sure to fill in the permit/license number which will be used as a reference number. In addition, an applicant that must submit multiple pehnit/license applications in any given year, need only submit one affidavit indicating current policy information (if necessary) and under "Job Site Address" the applicant should write "all locations in (city or town)." A copy of the affidavit that has been officially stamped or marked by the city or town may be provided to the applicant as proof that a valid affidavit is on file for future permits or licenses. A new affidavit must be filled out each year. Where a home owner or citizen is obtaining a license or permit not related to any business or commercial venture (i.e. a dog license or permit to bur leaves etc.) said person is NOT required to complete this affidavit The Office of Investigations would like to thank you in advance for your cooperation and should you have any questions, please do not hesitate to give us a call. The Department's address, telephone -and fax number: The Commonwealth of Massachusetts Department of Industrial Accidents Office of Investigations 600 Washington Street Boston, MA 02111 ....Tel.. #.6.17.-727-4900 ext 4066r _1-877-MASSAFE Fax # 617-727-7749 Revised 5 -26 -OS www.mass.gov/dia ENERGY CONSERVATION APPLICATION FORM FOR ENERGY EFFICICIENCY FOR ONE- AND TWO-FAMILY DETACHED RESIDENTIAL CONSTRUCTION (780 CMR 61.00) Applicant Name: Site Address: Print ,,O .' i10�ns, iKG , Town: Applicant Phone: ebp!;- oo . AM cloves ti t A 01 g9 -,— Applicant Signature: 1.4 Z\� Date of Application G7)o1cb NEW CONSTRUCTION: (choose ONE of the following two options) 780 CMR TABLE 6107.1 PRESCRIPTIVE ENVELOPE COMPONENT CRITERIA FOR NEW ONE- AND TWO-FAMILY BUILDINGS 124 O SF 100 x 76 . � - 12-40 = b . 7i % of glazing MAXIMUM MINIMUM Option l: PRESCRIPTIVE ENVELOPE COMPONENT CRITERIA ADDITIONS TO EXISTING Ceiling or MAXIMUM Basement Slab Ceiling and Fenestration exposed Wall Floor Wall Perimeter AFUE HSPF SEER Exposed floors U -factor floors R -Value R -Value R -Value R -Value and Depth .39 R -Value R-13 R-19 R-10 R-10, 4 feet and Depth area (i.e. not compressed over exterior walls, and including any access openings). ❑ SUNROOM - An addition or alteration to an existing building/dwelling unit where the total glazing area of said addition exceeds 40% of the combined gross wall and ceiling area of the addition. Note: Owner to fill out Consumer ln ormation Form (found in Appendix 120.P) R-10, National Appliance Energy Conservation Act R-38 R-19 R-19 R-10 (NAECA) of .35 4 ft 1987 as amended, minimums or greater as applicable Note: This form is not required if you choose either of the two versions of REScheck as listed below. ❑ Option 2: REScheck Version 4.1.2 or later variant software analysis must be completed (780 CMR 6107.3.2 REScheck-Web which can be accessed at http://www.energycodes.gov/reschecld ADDITIONS OR ALTERATIONS TO EXISTING BUILDINGS OVER 5 YEARS OLD* *Buildings under 5 years old must use option #I or #2 in New Construction section above. Complete the following formula to determine the % of glazing: (a) Gross Wall & Ceiling Area equals Formula: (100 x b _ a) 124 O SF 100 x 76 . � - 12-40 = b . 7i % of glazing (b) Glazing area equals 76 . h SF b a If glazing is <_40% use the chart below. If glazing is > 40 % proceed to "SUNROOM" section 780 CMR TABLE 6101.3 PRESCRIPTIVE ENVELOPE COMPONENT CRITERIA ADDITIONS TO EXISTING LOW-RISE RESIDENTIAL BUILDINGS MAXIMUM MINIMUM Ceiling and Slab Perimeter Fenestration Wall Floor Basement Wall U -factor Exposed floors R -Value R -value R -Value R -Value R -Value and Depth .39 R-37 a R-13 R-19 R-10 R-10, 4 feet a R-30 ceiling insulation may be used in place of R-37 if the insulation achieves the full R -value over the entire ceiling area (i.e. not compressed over exterior walls, and including any access openings). ❑ SUNROOM - An addition or alteration to an existing building/dwelling unit where the total glazing area of said addition exceeds 40% of the combined gross wall and ceiling area of the addition. Note: Owner to fill out Consumer ln ormation Form (found in Appendix 120.P) 1 GTS �-\ Board of Building Regulations and Standards HOME IMPROVEMENT CONTRACTOR Registraton;k, 128016 expiration 2I 1/2009 Tr# 263931 �IRiType Private Corporation ANDOVER REN11 TIONS, INC WILLIAM PENNY`�.`: 110 WINN ST WOBURN, MA 01801 Administrator -- ------ �ize iiJomrmtonure� o�✓vrcraaaciurGe� BOARD OF BUILDING REGULATIONS i License: CONSTRUCTION SUPERVISOR Number.- CS.. 079181 Birthdate 061953 Tr. no: 3556.0 Expwes.l4. /2008 Mz RestricPy-M WILLIAM C PENNY' 2 COPLEY DRIVE ANDOVER, MA 01810 -' Commissioner TRIPI ENGINEERING SERVICES. LLC 110 Winn Street, Suite 207 Woburn. Massachusetts 01301 www.tripiengineermg.com N OF M Project: 080049.00 Date: 6/11/2008 By: JMT PROJECT: I y LIPPMAN RENOVATION ,0 No. 45212 56 HAROLD STREET �o,� `�crSTEP�` NORTH ANDOVER, MA ass/ONAL�N�'\ 6-11-v8 CLIENT: ANDOVER RENOVATION SOLUTIONS, INC. Q PA 61M ;I it 14, 1b 2,.3 DESIGNER/ARCHITECT: A es /NlnxF-� ANDOVER RENOVATION SOLUTIONS, INC. 110 WINN STREET WOBURN, MA TRIPI ENGINEERING SERVICES LLC'S (TES) SCOPE OF WORK **: SIZING OF MEMBERS AND SUPPORTS SHOWN EXPLICITLY ON ATTACHED STAMPED DRAWINGS WITH SUPPORTING CALCULATIONS ONLY. **- NOTE: TES's scope of work is limited to design of the specific items indicated above. Design of other elements, if required, is the responsibility of others. Project Contractor(s) is responsible for constructing all work in accordance with all applicable codes and regulations. LIST OF CALCULATIONS: i. DESIGN CRITERIA ii. NOTES la RIDGE BEAM OVER PROPOSED NEW DORMER (TRIPLE LVL) lb RIDGE BEAM OVER PROPOSED NEW DORMER (DOUBLE LVL) 2 POST SELECTION TABLE 3 WINDOW HEADER TRIPI ENGINEERING SERVICES, LLC 110 "A%inn Street, Suite 207 Woburm Massachusetts 01301 vvx w. tripienggineerung.com DESIGN CRITERIA PROJECT NOTES BUILDING CODE IS MSBC 7th EDITION 1&2 FAMILY DWELLING CODE (780 CMR) LOADS ROOFS DEAD 15 PSF (ASPHALT SHING. OR EQUIV., WOOD FRAM.) GROUND SNOW = 55 PSF NORTH ANDOVER, MA) 1= 1.0 CATEGORY II Ce= 1.0 Ct= 1.1 FLAT -ROOF SNOW= 42 PSF ROOF SNOW LOADS COMPUTED BASED UPON FLAT ROOF SNOW AND REDUCTIONS BASED UPON ACTUAL ROOF SLOPES ATTIC DEAD 10 PSF LIVE 20 PSF (STORAGE) 10 PSF (NO STORAGE) 2nd FLOOR DEAD 12 PSF LIVE 30 PSF (SLEEPING AREAS) 40 PSF (REMAINING AREAS) 1st FLOOR DEAD 15 PSF LIVE 40 PSF (INTERIOR SPACES) WIND PER MSBC DEFLECTION CRITERIA*: Project: 080049.00 Date: 6/11/2008 By: JMT LIVE & SNOW LOAD TOTAL LOAD A) FLOORS & VENEER PLASTERED CLGS. U360 U240 B) OTHER, NON -FINISHED 0240 U180 *TES -RECOMMENDED MAXIMUM TOTAL LOAD DEFLECTIONS WERE IMPOSED AT SOME LOCATIONS AS INDICATED ON CALC. SHEETS 780CMR T5301.2(5) ASCE 7-02 .5 & 1.5 780CMR 5301.7 & T5301.7 TRIPI ENGINEERING SERVICES, LLC 110 Winn Street, Suite 207 Woburn. Massachusetts 01501 ,i -Ni -Na-. tripiengineer6ig. c om . Project: 080049.00 Date: 6/11/2008 By: JMT NOTES RELATED TO STRUCTURAL ELEMENTS SIZED BY TRIPI ENIGNEERING SERVICES LLC 1 ALL CONSTRUCTION TO CONFORM TO THE MASSACHUSETTS ONE AND TWO-FAMILY DWELLING CODE, 780 CMR, 7TH EDITION AND ALL APPLICABLE LOCAL REGULATIONS. THESE DRAWINGS/SKETCHES SHOW ENGINEERED MODIFICATIONS ONLY. CONTRACTOR IS SOLELY RESPONSIBLE FOR PROVIDING ADDITIONAL CONSTRUCTION, STRUCTURAL AND NOW STRUCTURAL, AS REQUIRED TO CONFORM TO THE REQUIREMENTS OF THE ABOVE -REFERENCED CODE AND ALL APPLICABLE REGULATIONS. CONTRACTOR TO COORDINATE ALL NECESSARY INSPECTIONS DURING THE CONSTRUCTION PHASE OF THE WORK. 2 CONTRACTOR IS SOLELY RESPONSIBLE FOR MEANS AND METHODS OF CONSTRUCTION, SUPERVISION, AND SAFETY DURING ALL PHASES OF THE WORK. CONTRACTOR SHALL PROVIDE SAFE ACCESS FOR ENGINEER TO OBSERVE DETAILS OF THE AS -BUILT AND EXISTING CONSTRUCTION AS REQUIRED. 3 CONTRACTOR TO CONTACT ENGINEER TO COORDINATE SITE VISITS DURING THE WORK. 4 CONTRACTOR TO NOTIFY STRUCTURAL ENGINEER OF ANY PROPOSED DEVIATION FROM DETAILS SHOWN ON THESE DRAWINGS/SKETCHES PRIOR TO PERFORMING THE WORK. 5 DESIGN CRITERIA: PER ATTACHED DESIGN CRITERIA PAGE, UNO 6 ALL NEW STEEL (IF APPLICABLE) TO BE ASTM A992 (MIN.). FINISH TO BE SHOP PRIMED PAINT UNLESS NOTED OTHERWISE. 7 ALL BOLTS TO BE ASTM A307 - MIN., UNO. 8 ALL NEW FRAMING TO BE SPRUCE -PINE -FIR NO.2 OR BETTER. BUILD UP AND FASTEN ALL FRAMING AS REQUIRED BY MSBC. ALL FASTENING TO BE IN ACCORDANCE WITH MSBC. GUN - DRIVEN NAILS FOR FRAMING CONNECTIONS SHALL BE 12d, 0.131 -INCH DIAMETER SHANK, MIN., EXCEPT WHERE LARGER NAILS ARE REQUIRED PER MSBC TABLE. 9 DO NOT DRILL HOLES THROUGH STRUCTURAL ELEMENTS EXCEPT AS ALLOWED BY CODE - SUBJECT TO ENGINEER'S PRIOR APPROVAL. DO NOT DRILL HOLES THROUGH STRUCTURAL POSTS / BUILT-UP COLUMNS. 10 PROVIDE SOLID BLOCKING FROM ALL POSTS CONTINUOUS DOWN TO FOUNDATION OR OTHER SUPPORT MEMBERS AS INDICATED ON PLAN. USE SQUASH BLOCKS OR SOLID LVL. 11 ALL NEW LVL TO BE Fb3100SP AS MANUFACTURED BY BOISE CASCADE, OR APPROVED EQUAL, INSTALL IN ACCORDANCE WITH ALL MANUFACTURER REQUIREMENTS / RECOMMENDATIONS FOR EACH APPLICATION. BUILD UP AS INDICATED IN CALCULATION PACKAGE. DO NOT DRILL HOLES THROUGH LVL FRAMING. 12 ALL NEW VERSALAM TO BE VERSALAM 2200 AS MANUFACTURED BY BOISE CASCADE, OR APPROVED EQUAL. DO NOT DRILL HOLES THROUGH VERSALAM POSTS. 13 ALL NEW ALLJOIST TO BE OF TYPE SHOWN ON DRAWINGS, AS MANUFACTURED BY BOISE CASCADE, OR APPROVED EQUAL. , INSTALL IN ACCORDANCE WITH ALL MANUFACTURER REQUIREMENTS / RECOMMENDATIONS FOR EACH APPLICATION. 14 ALL STRUCTURAL CONNECTORS TO BE SIMPSON STRONG -TIE, OF TYPE INDICATED ON PLANS OR ENGINEER -APPROVED EQUAL. PROVIDE COMPATIBLE FASTENERS OF TYPE REQUIRED FOR FULL CONNECTOR CAPACITY, TYP. LINO. BOISE" Triple 1-3/4" x 18" VERSA -LAM® 2.0 3100 SP Roof Beam1TRIPLE BC CALC® 9.5 Design Report - US 1 span I No cantilevers 10/12 slope Tuesday, June 10, 2008 23:55 Build 91 File Name: BC.BCC Job Name: LIPPMAN RENOVATION Description: TRIPLE Address: 56 HAROLD STREET Specifier: City, State, Zip: N. ANDOVER, MA Designer. JMTripi Customer: Company: TES Code reports: ESR -1040 Misc: '1*10 12 130, 3.1/2" LL 1316 lbs DL 3623 lbs SL 5528 lbs B1, 3-1/2" LL 1316 lbs DL 3623 lbs SL 5528 lbs Total Horizontal Product Length =19-06.00 Load Summary Live Dead Snow Wind Roof Live Tag Description Load Type Ref. Start End 100% 90% 115% 133% 125% Trib. 1 UNIFORM LOADS Unf. Lin. (plf) Left 00-00-00 19-06-00 135 345 567 n/a Cautions Column at Bearing BO analyzed for bearing only, column analysis has not been performed. Column at Bearing B1 analyzed for bearing only, column analysis has not been performed. For roof members with slope (1/4)/12 or less final design must ensure that ponding instability will not occur. For roof members with slope (1/2)/12 or less final design must account for Rain -on -Snow surcharge load. Notes Design meets User specified (U360) Total load deflection criteria. Design meets User specified (0480) Live load deflection criteria. Design meets arbitrary (0.625") Maximum load deflection criteria: Member Slope = 0, consider drainage. Connection Diagram b a minimum = 1-1/2"c = 7-1/2" b minimum = 4" d = 12" e minimum = 1" Install screws from both sides, staggering screws by Y2 of the spacing to avoid splitting. Pnnn gco ire: SDS 1/4 x 4-1/2 Ike Disclosure Completeness and accuracy of input must be verified by anyone who would rely on output as evidence of suitability for particular application. Output here based on building code -accepted design properties and analysis methods. Installation of BOISE engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (888)234-0056 before installation. BC CALCO, BC FRAMERS, AJS-, ALLJOIST®, BC RIM BOARD-, BCI®, BOISE GLULAM-, SIMPLE FRAMING SYSTEMS, VERSA -LAMS, VERSA -RIM PLUS®, VERSA -RIM®, VERSA -STRANDS, VERSA -STUD® are trademarks of Boise Wood Products, L.L.C. Load Controls Summary Value %Allowable Duration Case Span Location Pos. Moment 48658 ft -lbs 60.4% 115% 2 1 - Internal End Shear 8544 lbs 41.4% 115% 2 1 - Left Total Load Defl. U367 (0.622") 98.0% 2 1 Live Load Defl. U562 (0.407') 85.5% 2 1 Max Defl. 0.622" 99.6% 2 1 Span / Depth 12.7 n/a 0 1 % Allow % Allow Bearing Supports Dim. (L x W) Value Support Member Material BO Post 3-1/2" x 5-1/4" 10467 lbs 78.6% 76.0% Spruce -Pine -Fir B1 Post 3-1/2" x 5-1/4" 10467 lbs 78.6% 76.0% Spruce -Pine -Fir Cautions Column at Bearing BO analyzed for bearing only, column analysis has not been performed. Column at Bearing B1 analyzed for bearing only, column analysis has not been performed. For roof members with slope (1/4)/12 or less final design must ensure that ponding instability will not occur. For roof members with slope (1/2)/12 or less final design must account for Rain -on -Snow surcharge load. Notes Design meets User specified (U360) Total load deflection criteria. Design meets User specified (0480) Live load deflection criteria. Design meets arbitrary (0.625") Maximum load deflection criteria: Member Slope = 0, consider drainage. Connection Diagram b a minimum = 1-1/2"c = 7-1/2" b minimum = 4" d = 12" e minimum = 1" Install screws from both sides, staggering screws by Y2 of the spacing to avoid splitting. Pnnn gco ire: SDS 1/4 x 4-1/2 Ike Disclosure Completeness and accuracy of input must be verified by anyone who would rely on output as evidence of suitability for particular application. Output here based on building code -accepted design properties and analysis methods. Installation of BOISE engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (888)234-0056 before installation. BC CALCO, BC FRAMERS, AJS-, ALLJOIST®, BC RIM BOARD-, BCI®, BOISE GLULAM-, SIMPLE FRAMING SYSTEMS, VERSA -LAMS, VERSA -RIM PLUS®, VERSA -RIM®, VERSA -STRANDS, VERSA -STUD® are trademarks of Boise Wood Products, L.L.C. BOISE Double 1-3/4" x 24" VERSA -LAM® 2.0 3100 SP Roof Beam1DOUBLE BC CALCO 9.5 Design Report - US 1 span I No cantilevers 0/12 slope Tuesday, June 10, 2008 23:55 Build 91 File Name: BC.BCC Job Name: LIPPMAN RENOVATION Description: DOUBLE Address: 56 HAROLD STREET Specifier: City, State, Zip: N. ANDOVER, MA Designer: JMTripi Customer: Company: TES Code reports: ESR -1040 Misc: 130, 5-1/C LL 1316 lbs DL 3594 lbs SL 5528 lbs 81, 5-1/4" LL 1316 lbs DL 3594 lbs SL 5528 lbs Total Horizontal Product Length =1946-00 Load Summary Live Dead Snow Wind Roof Live Tag Description Load Type Ref. Start End 1000/0 90% 115% 133% 125% Trib 1 UNIFORM LOADS Unf. Lin. (plf) Left 00-00-00 19-06-00 135 345 567 n/a Cautions Column at Bearing BO analyzed for bearing only, column analysis has not been performed. Column at Bearing B1 analyzed for bearing only, column analysis has not been performed. For roof members with slope (1/4)/12 or less final design must ensure that ponding instability will not occur. For roof members with slope (1/2)/12 or less final design must account for Rain -on -Snow surcharge load. Notes Design meets User specified (U360) Total load deflection criteria Design meets User specified (U480) Live load deflection criteria. Design meets arbitrary (0.625") Maximum load deflection criteria. Member Slope = 0, consider drainage. 1 7{ b a minimum = 1-1/2%= 10-1/2" 16 b minimum = 4" d = 12" 1116— e minimum = 1" Connectors are: SDS 1/4 x 3-1/2 Page 1 of 1 Disclosure Completeness and accuracy of input must be verified by anyone who would rely on output as evidence of suitability for particular application. Output here based on building code -accepted design properties and analysis methods. Installation of BOISE engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (888)234-0056 before installation_ BC CALCO, BC FRAMER®, AJSTm, ALUOISTO , BC RIM BOARD-, BCI® , BOISE GLULAMTM, SIMPLE FRAMING SYSTEM®, VERSA -LAM®, VERSA -RIM PLUS®, VERSA -RIM®, VERSA -STRAND®, VERSA -STUDS are trademarks of Boise Wood Products, L.L.C. Load Controls Summary Value %Allowable Duration Case Span Location Pos. Moment 47049 ft -lbs 50.9% 115% 2 1 - Internal End Shear 7829 lbs 42.7% 115% 2 1 - Left Total Load Defl. 0609 (0.369") 59.1% 2 1 Live Load Defl. 0929 (0.242") 51.6% 2 1 Max Defl. 0.369" 59.1% 2 1 Span / Depth 9.4 n/a 0 1 % Allow % Allow Bearing Supports Dim. (L x W) Value Support Member Material BO Post 5-1/4" x 3-1/2" 10439 lbs 78.4% 75.7% Spruce -Pine -Fir B1 Post 5-1/4" x 3-1/2" 10439 lbs 78.4% 75.7% Spruce -Pine -Fir Cautions Column at Bearing BO analyzed for bearing only, column analysis has not been performed. Column at Bearing B1 analyzed for bearing only, column analysis has not been performed. For roof members with slope (1/4)/12 or less final design must ensure that ponding instability will not occur. For roof members with slope (1/2)/12 or less final design must account for Rain -on -Snow surcharge load. Notes Design meets User specified (U360) Total load deflection criteria Design meets User specified (U480) Live load deflection criteria. Design meets arbitrary (0.625") Maximum load deflection criteria. Member Slope = 0, consider drainage. 1 7{ b a minimum = 1-1/2%= 10-1/2" 16 b minimum = 4" d = 12" 1116— e minimum = 1" Connectors are: SDS 1/4 x 3-1/2 Page 1 of 1 Disclosure Completeness and accuracy of input must be verified by anyone who would rely on output as evidence of suitability for particular application. Output here based on building code -accepted design properties and analysis methods. Installation of BOISE engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (888)234-0056 before installation_ BC CALCO, BC FRAMER®, AJSTm, ALUOISTO , BC RIM BOARD-, BCI® , BOISE GLULAMTM, SIMPLE FRAMING SYSTEM®, VERSA -LAM®, VERSA -RIM PLUS®, VERSA -RIM®, VERSA -STRAND®, VERSA -STUDS are trademarks of Boise Wood Products, L.L.C. 32 The same properties that make VERSA -LAM® beams great, also make them highly suitable for wood columns. In VERSA -LAM® columns, you'll find none of the deep checks, cracks or twists that can plague solid wood columns and there's no need to box in VERSA -LAM® beams good looks. VERSA -LAW 2200 Column Table o pp Allowable Design !Values Product Bending Fb [psi]pt Compression Parallel to Grain F. [psi] Iorizontal Shear FY sl [psi] Modulus of Elasticity E [psi] Allowable Axial Load (Lb) 100% Load Duration 2722(3) 3000 285 VQ 4 k k� Q rr 15,160 16,600 17,465 Q Ei►[� rr 22,700 24,860 26,160 W91n W, WW n W rr rr rr wr ra F rr', No. 2 SPF 2x6 5 12,655 13,555 14,080 18,990 20,345 21,135 No. 2 Hem Fir 2x6 1271 1250 75 1300000 6 10,385 10,970 11,305 15,590 16,465 16,970 20,790 21,955 22,635 33,340 36,540 38,450 7 8,555 8,955 9,185 12,840 13,440 13,785 17,125 17,925 18,385 29,745 32,105 33,495 8 7,125 7,405 7,570 10,690 11,115 11,360 14,260 14,825 15,155 26,200 27,940 28,955 34,950 37,265 38,620 9 6,000 6,210 6,330 9,005 9,320 9,500 12,010 12,430 12,670 22,995 24,310 25,075 30,675 32,425 33,445 10 11 5,110 5,270 5,360 4,400 4,525 4,595 7,675 6,605 7,9 0 8,045 16,790 6,895 10,235 110,5501 8,810 10,730 20,220 121,235 21,825 9,055 9,195 17,850 18,650 19,115 26,970 23,810 28,325 29,110 24,880 25,495 12 3,825 3,920 3,975 5,740 5,885 5,970 7,660 7,850 7,960 15,830 16,475 16,850 21,120 21,980 22,475 13 3,355 3,430 3,475 5,035 5,150 5,215 6,715 6,870 6,955 14,115 14,640 14,945 18,830 19,530 19,935 14 2,960 3,025 3,060 4,445 4,540 4,595 5,930 6,055 6,130 12,650 13,085 13,330 16,875 17,450 17,785 33,415 35,020 35,950 15 11,390 11,750 11,960 15,195 15,675 15,955 30,490 31,845 32,630 116 10,305 10,610 10,780 13,745 14,150 14,385 27,900 29,050 29,715 17 9,360 9,620 9,765 12,490 12,830 13,030 25,600 26,585 27,155 18 8,540 8,760 8,885 11,390 11,685 11,855 23,%0 24,405 24,900 19 7,820 8,010 8,115 10,430 10,685 10,830 21,740 22,475 22,900 20 7,185 7,345 7,440 9,580 9,800 9,930 20,110 20,755 21,125 21 6,620 6,765 6,845 8,830 9,025 9,135 18,655 19,220 19,545 22 17,345 17,845 18,130 23 16,160 16,605 16,860 24 15,095 15,490 15,715 Allowable Design Stresses w d • Table assumes that the column is braced at column ends only. Effective column length tial to actual column length. • Tables are based on one-piece column members used in dry service conditions. • Allowable loads in an eccentricity value value of 0.167 of column thidmess (first dimension). is • Allowable loads are based on axial loading columns using the design provisions of the National Design Specification? for Wood Construction (NDS), 1997 edition. For side other combined bending and axial loads, provisions of NDS, 1997 edition. or see Modulus of Elasticity E =1.8 x 106 psi Flexural stress Fb = 2200(12/d)'" psi Tension roller to rain F -1600 9 r - Horizontal shear perpendicular to glue line Fv = 285 psi ° Compression parallel to grain Fd = 3000 psi Compression perpendicular to grain F, = 900 psi parallel to glue line o pp Allowable Design !Values Product Bending Fb [psi]pt Compression Parallel to Grain F. [psi] Iorizontal Shear FY sl [psi] Modulus of Elasticity E [psi] 2400Fb DF VERSA -STUD® 2722(3) 3000 285 2000000 2900Fb SP VERSA -STUD® 3289(4) 3000 290 2000000 No. 2 SPF 2x6 1121 1100 70 1100000 No. 2 Hem Fir 2x6 1271 1250 75 1300000 No. 2 D Fir -L 2x6 1308 1300 95 1600000 1) Design values are for loads applied to the narrow face of the studs. 2) Repetitive member and size factors have been applied ^ 3) For a 51/2 inch depth. Use 2862 psi and 2640 psi for 3%2 and 7A inch depths, respectively. L 4) For a 51/2 inch depth. Use 3459 psi and 3190 psi for 31h and 71/4 inch depths, respectively. 5) Dimension lumber design values per the 1997 NDS. BOISE, Double 1-3/4" x 7-1/4" VERSA -LAM® 2.0 3100 SP Floor Beam1HEADER BC CALC® 9.5 Design Report - US 1 span I No cantilevers 10/12 slope Wednesday, June 11, 2008 00:19 Build 91 lmu!p� SL 2764 lbs D t_ 7 824 I Ips S L 2764 I bs Tot�1 Horizor�t�1 F�rocluc Load Summary Live Dead Snow Wind Roof live Tag Description Load Type Ref. Start End 100% 90% 115% 133% 125% Trib 1 RIDGE POINT LOAD Conc. Pt. (Ibs) Left 01-09-00 01-09-00 1316 3623 5528 n/a Controls Summary File Name: BC.BCC Job Name: LIPPMAN RENOVATION Description: HEADER Address: 56 HAROLD STREET Specifier: City, State, Zip: N. ANDOVER, MA Designer: JMTripi Customer: Company: TES Code reports: ESR -1040 Misc: lmu!p� SL 2764 lbs D t_ 7 824 I Ips S L 2764 I bs Tot�1 Horizor�t�1 F�rocluc Load Summary Live Dead Snow Wind Roof live Tag Description Load Type Ref. Start End 100% 90% 115% 133% 125% Trib 1 RIDGE POINT LOAD Conc. Pt. (Ibs) Left 01-09-00 01-09-00 1316 3623 5528 n/a Controls Summary Value %, Allowable Duration Load Case Span Location Pos. Moment 7907 ft -lbs 82.1% 115% 2 1 - Internal End Shear 5240lbs 94.5% 115% 2 1 - Left Total Load Defl. L/764 (0.048") 31.4% 2 1 Live Load Defl. L/1170 (0.031") 30.8% 2 1 Max Defl. 0.048" 19.1% 2 1 Span / Depth 5.0 n/a 0 1 Bearing Supports Dim. (L x W) Value % Allow Support % Allow Member Material BO Post 3-1/2" x 3-1/2" 5246lbs 59.1% 57.1% Spruce -Pine -Fir B1 Post 3-1/2" x 3-1/2" 5246 lbs 59.1% 57.1% Spruce -Pine -Fir Cautions Column at Bearing BO analyzed for bearing only, column analysis has not been performed. Column at Bearing B1 analyzed for bearing only, column analysis has not been performed. Notes ueslgn meets coae minimum (L/240) Total load deflection criteria. Design meets Code minimum (L/360) Live load deflection criteria. Design meets arbitrary (0.25") Maximum load deflection criteria. Connection Diagram d * • C V 0 a minimum = 1-1/2"c = 4-1/4" b minimum = 4" d = 12" e minimum = 1" Connection design assumes point load is 'top -loaded'. For connection design of 'side -loaded' point loads, please consult a technical representative or professional of Record. Install Screws with screw heads in the loaded ply. Member has no side loads. Concentrated loads are not considered in side load analysis. Connectors are: SDS 1/4 x 3-1/2 Page 1 of 1 Disclosure Completeness and accuracy of input must be verified by anyone who would rely on output as evidence of suitability for particular application. Output here based on building code -accepted design properties and analysis methods. Installation of BOISE engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (888)234-0056 before installation. BC CALC®, BC FRAMER®, AJS-, ALLJOIST®, BC RIM BOARD-, BCI®, BOISE GLULAM-, SIMPLE FRAMING SYSTEM®, VERSA -LAM®, VERSA -RIM PLUS®, VERSA -RIM®, VERSA -STRANDS, VERSA -STUD® are trademarks of Boise Wood Products, L.L.C. 3 AWT