Loading...
HomeMy WebLinkAboutBuilding Permit #972-15 - 66 COMPASS POINT ROAD 5/27/2015BUILDING PERMIT TOWN OF NORTH ANDOVER APPLICATION FOR PLAN EXAMINATION Permit No#: Date Received Date Issued: IL, 111-7 IMPORTANT: Applicant must complete all items on this page LOCATION n.00,S& Q 010� 61a 0 PROPERTYOWNER "�,-(J-Lprint Print 100 Year Structure yes nA MAP PARCEL: -D-63 ZONING DISTRICT: Historic District yes V- rx, Machine Shop Village yes TYPE OF IMPROVEMENT PROPOSEDUSE Residential Non- Residential El New Building El One family El Addition XTwo or more f mily El Industrial El Alteration No. of units: q 0 Commercial El Repair, replacement El Assessory Bldg El Others: [I Demolition El Other 0, Flooclp,(4in ­WiR eddb istriic-t M W -ate 0 WAte US,ewia r DESCRIPTION OF WORK TO BE PEKI-UMLL): Ya &4) 0znCk)f�"6\0n0 Co'c CAO�2�L or Frinttuieariv OWNER: Name: Address: 5k (nA--�W T�f 'A�LZ"V12Uf(A M,,- Q\�Ok Contractor Name: Phone: Address: Vb lyok \;;)' �>-bfU*-JynT\ \vlc,- Supervisor's Construction License:- LS _Exp. Date: t�2 (-\ sfo 11 Home Improvement License: \ LkS -750c> Exp. Date: -1 �� ( �Q - ARCH ITECT/ENGI NEER U,�Lr, Phone: 00bo 331 -sas; Address: ver 'I'LC At Reg. No. 33-7 C)— FEE SCHEDULE. BULDING PERMIT. $12.00 PER $1000.00 OF THE TOTAL ESTIMATED cosrBAsED ON $125.00 PER S.F. a -I I & -13 to 4 (+_1 z - Total Project Cost: $ I FEE: $ Check No.: Receipt No.: NOTE: Persons contractinglAth unregistered contractors do not have access to the gVarantyfund Location (.0 �p 0 No. (I -I zz— ( — Dateq V1 It Check # TOWN OF NORTH ANDOVER Certificate of Occupancy s— LO�-- Building/Frame Permit Fee Foundation Permit Fee Other Permit Fee TOTAL Building Inspector Plans Submitted D Plans Waived Certified Plot Plan Stamped Plans TYPE OF SEWERAGE DISPOSAL Public Sewer Tanuffig/Massage/Body Art 0 Swilling Poll, 11 well Tobacco Sales 0 Food Packaging/Sales 0 Private (septic tank etc. Pennanent Dumpster on Site D THE FOLLOWING SECTIONS FOR OFFICE USE ONLY INTERDEPARTMENTAL SIGN OFF - U FORM PLANNING & DEVELOPMENT Reviewed On COMMENTS Signature. CONSERVATION Reviewed on. Si-qnatur6—", U COMMENTS HEALTH Reviewed on Signature COMMENTS Zoning Board of Appeals: Variance, Petition No: Zoning Decision/receipt submitted yes Planning Board Decision: Comments 411, Conservation Decision: Com Water & Sewer Connection/silqnature & DatfiK ]DPW Town Engineer: Signature: -1. - : i i,: =: � i! � - RE 11: � P R111.10! i -j -Zi-rfe- 51 ns nt.qi 5'—z"-2r1ve1 Located 384 c' " i"� -L—atz ?F-,i��F!�- �,e _,:ep_ 'o' i� M N AV od Street Dimension Number of Stories: 3 Total square feet of floor area, based on Exterior dimensions.OR 11 Total land area, sq. ft.: ELECTRICAL: Movement of Meter location, mast or service drop requires approval of Electrical Inspector Yes No DANGER ZONE LITERATURE: Yes MGL Chapter 166 Section 21A —F and G min.$100-$1000 fine NO I t5 and DA I A — (For LI Notified for pickup Cal artment use mai Date Time Contact Name Doc.Building Pennit Revised 2014 mil Building Department The following is a list of the required forms to be filled out for the appropriate permit to be obtained. Roofing, Siding, Interior Rehabilitation Permits Building Permit Application Workers Comp Affidavit Photo Copy Of H.I.C. And/Or C.S.L. Licenses ,6 Copy of Contract 4= Floor Plan Or Proposed Interior Work 4� Engineering Affidavits for Engineered products OTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit Addition Or Decks 4� Building Permit Application 4� Certified Surveyed Plot Plan ,4. Workers Comp Affidavit Photo Copy of H.I.C. And C.S.L. Licenses Copy Of Contract Floor/Cross Section/Elevation Plan Of Proposed Work With Sprinkler Plan And Hydraulic Calculations (If Applicable) Mass check Energy Compliance Report (If Applicable) Engineering Affidavits for Engineered products TE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit New Construction (Single and Two Family) Building Permit Application Certified Proposed Plot Plan Photo of H.I.C. And C.S.L. Licenses Workers Comp Affidavit Two Sets of Building Plans (One To Be Returned) to Include Sprinkler Plan And Hydraulic Calculations (if Applicable) Copy of Contract 2012 IECC Energy code Engineering Affidavits for Engineered products 10TE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg. Permit In all cases if a variance or special permit was required the Town Clerks office must stamp the decision from the Board of Appeals that the appeal period is over. The applicant must then get this recorded at the Registry of Deeds. One copy and proof of recording must be submitted with the building application Doe: Building Permit Revised 2014 CONSTRUCTION CONTRACTOR REPORT MASSACHUSETTS BUILDINGCODE SECTION REPORT NO: Eighteen Bldg.G - #805-15 TO: Building Commissioner- Permit Number Bldg.H - #506-15 400 Osgood Street, N Andover, MA Bldg. I - #505-15 Bldg. J - #072-2016 Merrimack Condominiums PROJECT NAME OR NUNIBER: - 60, 62, 64, &-66 Compass Point, Units G 1, G2, G3, & G4 STREET ADDRESS: 52 & 50 Compass Point, Units HI & H2 48 & 46 Compass Point, Units 11 & 12 TOWN/CITY: Nortb Andover, MA WORK: GENERAL CONTRACTOR: TRUST CONSTRUCTION CORPORATION CONSTRUCTION SUPERINTENDENT: Timothy Barlow UP DATE PREVIOUS ISSUES: DATES COVERED: CONDITIONS: 178 2015 through July 23, 201 � Partial Sunny Spring Day - 64F LICENSE# CS 059359 Buiding "D" is 70% complete. COMMENTS: Installation of electric & plumbing rough -ins are in progress in Building "H" & ?fill WORK IN PROGRESS Puilding "I" - framing is 90% complete. Building "H" - framing is 90% complete. Building "G" - framing is 60% complete. In general low soffit in garage should be limited to 2' width off walls. S171E VISITS: Inspected on July 23 for the excavation for "J" & progressing work in D, G, H & 1. RELATEDISSUES: ACTION REQUIRED: ADDITIONS TO FILED PLANS: STATUS OF COWLETION: % 48% of the all 15 buildings REPORTING ARCHITECT: Kanayo Lala IN CONPLIANCE WITF1 MASSACHUSETTS STATE BUILDING CODE, SECTION 107.6.4 CONSTRUCTION CONTROL AND APPROVED PLANS Kanayo Lala ARCHITECT OF RECORD: — ��,& _DAIE: JULY 23, 2015 Enter construction cost for fee cal - North Andover Fee Calculation Construction Cost $ 271,875.00 m $ - $ 3,262.50 Plumbing Fee $ 407.81 Gas Fee 100 comm. $ 100.00 Electrical Fee $ 407.81 Total fees collected $ 4,178.13 66 Compass Point 972-15 on 5/27/15 New Townhome U) 0 CD 0 z r-qpk o CD CL 2) CL > co 0 00 < Q CD CL cr CD 0 CD CL 0 S' = CM CD F Cl) a CD 0 r.*L 0 7 0 0 U) 0 CD 0 CD CD CD U) 0 m 0 CD B 0 CD 'r—I z rl m U) Cl) 0 0 z cn cn m 0 —a m X m X 0 55 m Cl) z 0 z Cl) 0 0 mo — =r --i 0 = " 0 0) = -h 0 U) Wo U) = :5. .0 FA CD CL 0 CD 0 CD C-) 0 r.L CM) m o T. 75 CD 0 — 0 0 CL m =R = 2) con) CD r -OL 0 (n 0 CD '0 - - CD (D im R @ > F = 0 to CL Do) C=D' (D -!� --1 0 0 , co 0 0 z U) 0 0 rr CD U) 0 rL 0 (a < CD 0 0 CL U) CO) a) :0 = CD it EEL FL- ch a) -a :* (D (low CO) 0 cc) U3 =r CD ug _0 CD C') U) - -0 h CD (D a " Ly 2) 0 CL mikob,") wow v (4n LA 03 Ln ;;o -n W -n 3 0 0 =3 0 =5 2: 0 rD 0 0 c 9L c E c 9L c 'a 0 X, (D aq 5 . CrQ aq 3 =) — CL rD - q =r n =- =r =3 0- K -, z rD (D LA rD 0 m M :3 rD r- (D m c C 3 F= 0 m > m z M > 0 "n M m m m m m z 0 0 0 v (4n C v (4n RESc eck Software Version 4.6.1 Compliance Certificate Project 15 052 7—Trust—M erri mac_BldgG_U n itG4—Model B Energy Code: 2012 IECC Location: North Andover, Massachusetts Construction Type: Multi -family Project Type: New Construction Conditioned Floor Area: 2,326 ft2 Glazing Area 12% Climate Zone: 5 (6322 HDD) Permit Date: 0.0 Permit Number: 40 Construction Site: Bldg G, Unit G4 North Andover, MA Owner/Agent; Designer/Contractor: 9�lffim qmio 91� wllaEl� - - I Compliance: 0.0% Better Than Code Maximum UA: 327 Your UA: 327 The % Better or Worse Than Code Index reflects how close to compliance the house is based an code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home. Envelope Assemblies Floor Ist Floor: All -Wood joist/Truss: Over Unconditioned Space 416 30.0 0.0 0.033 14 Wall lst Separation: Wood Frame, 16" o.c. 96 15.0 0.0 0.077 7 Wall Ist Ext 2x6: Wood Frame, 16" o.c. 812 21.0 0.0 0.057 40 Window Dh: Vinyl Frame:Double Pane with Low -E 32 0.290 9 Door Front Ground Fir entry: Glass 20 0.260 5 Door Back: Glass 34 0.290 10 Door Metal: Solid 18 0.160 3 Floor 2nd Over garage/entry: All -Wood joist/Truss: Over Unconditioned Space 481 30.0 0.0 0.033 16 Floor 2nd Over entry: All -Wood Joistfrruss: Over Outside Air 39 30.0 0.0 0.033 1 Wall 2nd Floor 2x6: Wood Frame, 16" o.c. 855 21.0 0.0 0.057 39 Window DH: Vinyl Frame:Double Pane with Low -E 100 0.290 29 Window Fix: Vinyl Frame:Double Pane with Low -E 19 0.280 5 Window CSMT: Vinyl Frame:Double Pane with Low -E 12 0.260 3 Door Slider: Glass 34 0.290 10 Wall 2nd Fir Separation: Wood Frame, 16" o.c. 279 15.0 0.0 0.077 21 Ceiling Bay Win: Flat Ceiling or Scissor Truss 6 30.0 0.0 0.035 0 Wall 3rd Floor: Wood Frame, 16" o.c. 749 21.0 0.0 0.057 36 Window DH: Vinyl Frame:Double Pane with Low -E 86 0.290 25 Project Title: 150527 — Trust — Merrimac_BldgG_L1nitG4_ModelB Report date: 05/27/15 Data filename: S:\Ebbeling Ed\150507 Trust—MerrimacCondos—BidgG_UnitsBB- Pagel of 9 BB—NAndover\Rescheck\150527—Trust—Merrimac—BidgG_UnitG4—ModelB.rck i Window Awn: Vinyl Frame:Double Pane with Low -E 7 0.270 2 DoorFrench: Glass 18 0.260 5 Wall 3rd Separation: Wood Frame, 16" o.c. 243 15.0 0.0 0.077 19 Ceiling Main: Flat Ceiling or Scissor Truss 936 38.0 0.0 0.030 28 Compliance Statement. The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in REScheck Version 4.6.1 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. e - Project Notes: Building G nature Date Project Title: 150527 — Trust — Merrinnac_BldgG—UnitG4—ModelB Report date: 05/27/15 Data filenanne: S:\Ebbeling Ed\150507—Trust MerrimacCondos—BldgG_UnitsBB- Page 2 of 9 BB—NAndover\Rescheck\l��-0527—Trust—Merri—mac—BidgG_UnitG4—ModelB.rck REScheck Software Version 4.6.1 Inspection Checklist C�(J Energy Code: 2012 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Pre-inspection/Plan Review Plans Verified Value Field Verified T Value Complies? yom:m ents/Assumptions & Req.113 103.1, ;Construction drawings and ElComplies 103.2 'documentation demonstrate E]Does Not [PR1111 energy code compliance for the E]Not Observable a building envelope. E]Not Applicable 103.1, Construction drawings and ElComplies 103.2, documentation demonstrate E]Does Not 403.7 energy code compliance for :,E]Not Observable [PR311 lighting and mechanical systems. Systems serving multiple EINot Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ElComplies 403.6 sized per ACCA Manual S based Btu/hr Btu/hr— 'E]Does Not [PR2 ]2 on loads calculated per ACCA Cooling: Cooling: E]Not Observable 14 Manual J or other methods approved by the code official. Btu/hr Btu/hr EINot Applicable Additional Comments/Assumptions: I I High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: 150527–Trust–Merrimac_BldgG–UnitG4–ModelB Report date: 05/27/15 Data filename: S:\Ebbeling_Ed\150507–Trust – MerrimacCondos–BldgG_UnitsBB- Page 3 of 9 BB–NAndover\Rescheck\150527–Trust–Merrimac_BldgG_UnitG4–ModelB.rck 2012 IECCI Foundation Inspection Complies? Comments/Assumptions 303.2.1 A protective covering is installed to OComplies [FO11]? protect exposed exterior insulation ElDoes Not 10 and extends a minimum of 6 in. below ONot Observable grade. E]Not Applicable 403.8 Snow- and ice -melting system controls'E]Com plies [FO12]2 installed. ElDoes Not [:]Not Observable E]Not Applicable Additional Comments/Assumptions: 111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Ti Project Title: 150527 - Trust J Merrimac_BldgG-UnitG4-ModelB Report date: 05/27/15 Data filenarne: SAEbbeling - Ed\150507-Trust - MerrirnacCondos_BldgG_UnitsBB- Page 4 of 9 BB-NAndover\Rescheck\l�'0527-Trust-Merrimac-BldgG_UnitG4-ModelB.rck S ection # Framing / Rough- 1, 1,specti7,, Plans Verified Value Field Verified Value Complies? Comments/Assumptions & Req.111) 402.1.1, Door U -factor. U_ U_ ElComplies See the Envelope Assemblies 402.3.4 ElDoes Not table for values. [FRI]' E]Not Observable 0 �E]Not Applicable 402.1.1, Glazing U -factor (area -weighted U- U_ tlComplies See the Envelope Assemblies 402.3.1, average). ElDoes Not table for values. 402.3.3, 402.3.6. E]Not Observable 402.5 EINot Applicable [FR211 303.1.3 U -factors of fenestration products �OComplies [FR411 are determined in accordance ElDoes Not with the NFRC test procedure or IE]Not Observable taken from the default table. EINot Applicable 402.4.1.1 Air barrier and thermal barrier OComplies FR2311 installed per manufacturer's ElDoes Not instructions. EINot Observable ONot Applicable 402.4.3 Fenestration that is not site built DComplies [FR2011 is listed and labeled as meeting ElDoes Not AAMA /WDMA/CSA 101/i.S.2/A440 ONot Observable 1 ,or has infiltration rates per NFRC EINot Applicable 400 that do not exceed code limits. 402.4.4 IC -rated. recessed lighting fixtures, ElComplies [FR16]2 sealed at housing/interior finish ElDoes Not 9 and labeled to indicate :52.0 cfm EJNot Observable leakage at 75 Pa. EJNot Applicable 403.2.1 Supply ducts in attics are R- R- ElComplies [FR12]1 insulated to �:R-8. All other ducts R- R- '!ODoes Not in unconditioned spaces or EINot Observable outside the building envelope are Applicable insulated to 2:11-6. :ONot 403.2.2 �All joints and seams of air ducts, Complies [FR13]1 'air handlers, and filter boxes are ODoes Not sealed. ONot Observable EINot Applicable 403.2.3 Building cavities are not used as ElComplies [FR15]3 ducts or plenums. ElDoes Not 14 0Not Observable TINot Applicable 403.3 HVAC piping conveying fluids R- R- ElComplies [FR17]2 above 105 9F or chilled fluids 'ODoes Not 10) below 55 OF are insulated to �tlk- EINot Observable 3. ONot Applicable 403.3.1 Protection of insulation on HVAC OComplies [FR2411 piping. ElDoes Not EINot Observable ONot Applicable 403.4.2 Hot water pipes are insulated to R- R- FIcomplies [FR18]2 aR-3. 'ODoes Not -E]Not Observable EINot Applicable 11 High Impact (Tier 1) 2 1 Medium lmpact.(Tier 2) 3 1 Low lmpa7c7tJTTier3) Project Title: 150527 — Trust — Merrimac — BldgG_UnitG4 — ModelB Report date: 05/27/15 Data filename: S:\Ebbeling - Ed\150507—Trust — MerrimacCondos_BldgG_UnitsBB- Page 5 of 9 BB—NAndover\Rescheck\l��0527—Trust—Merrimac—BldgG�_UnitG4—ModelB.rck Section Plans Verified Field Verified � # Framing / Rough -in Inspection Value Value Complies? Comments/Assumptions & Req.111) 403.5 Automatic or gravity dampers are ElComplies [FR 19]2 installed on all outdoor air E]Does Not intakes and exhausts. E]Not Observable E]Not Applicable Additional Comments/Assumptions: I I I High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impa Project Title: 150527 - Trust-Merrimac.BidgG-UnitG4-ModelB Report date: 05/27/15 Data filename: 5:\Ebbeling_Ed\150507-Trust - MerrimacCondos-BidgG-UnitsBB- Page 6 of 9 BB-NAndover\Rescheck\150527-Trust-Merrimac-BidgG_UnitG4-ModelB.rck Section # Insulation Inspection Plans Verified Value Field Veri T;��� fled Value Complies? Comments/Assumptions & Req.ID 303.1 All installed insulation is labeled ElComplies [IN13 ]2 or the installed R -values E]Does Not 10) provided. EJNot Observable E]Not Applicable 402.1.1, Floor insulation R -value. R- R- []Complies See the Envelope Assemblies 402.2.6 Wood F] Wood E]Does Not table for values. [IN1]1 E] Steel E] Steel []Not Observable EINot Applicable 303.2, Floor insulation installed per ElComplies 402.2.7 ;manufacturer's instructions, and ElDoes Not [IN211 in substantial contact with the EINot Observaule under -side of the subfloor. E]Not Applicable 402.1.1, Wall insulation R -value. If this is a R- R- ElComplies See the Envelope Assemblies 402.2.5, mass wall with at least 1/z of the Wood F1 Wood DDoes Not table for values. 402.2.6 [IN311 wall insulation on the wall �exterior, the exterior insulation E] Mass E] Mass :E]Not Observable requirement applies (FR10). E] Steel Steel EJNot Applicable 303.2 Wall insulation is installed per ElComplies [IN411 manufacturer's instructions. E]Does Not [JNot Observable E]Not Applicable Additional Comments/Assumptions: 11 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: 150527 - Trust - Merrirnac_BIdgG-UnitG4-ModeIB Report date: 05/27/15 Data filename: S:\Ebbeling_Ed\150507-Trust - MerrirnacCondos-B1dgG-UnitsBB- Page 7 of 9 BB-NAndover\Rescheck\150527-Trust-Merrimac-BldgG_UnitG4-ModelB.rck Section # I Final Inspection Provisions ; Plans Verified Value Field led V=f Value Complies? Comments/Assumptions & Req.1D 402.1.1, Ceiling insulation R -value. R- R- ElComplies See the Envelope Assemblies 402.2.1, [J Wood F] Wood DDoes Not table for values. 402.2.2, 402.2.6 E] Steel Steel F]Not Observable [Fl1]1 E]Not Applicable 0 303.1.1.1, Ceiling insulation installed per ElComplies 303.2 manufacturer's instructions. E]Does Not [F12]11 Blown insulation marked every EJNot Observable 300 ft2. E]Not Applicable 402.2.3 Vented attics with air permeable ElComplies [F122]2 insulation include baffle adjacent ODoes Not to soffit and eave vents that EINot Observable extends over insulation. []Not Applicable 402.2.4 �Attic access hatch and door R- R- ElComplies [F1311 insulation a:R-value of the ElDoes Not .adjacent assembly. 'E]Not Observable 'E]Not Applicable 402.4.1.2 Blower door test @ 50 Pa. < =5 ACH 50 ACH 50 ElComplies [FI17]1 ach in Climate Zones 1-2, and E]Does Not 19 <=3 ach in Climate Zones 3-8. E]Not Observable E]Not Applicable 403.2.2 Duct tightness test result of <=4 cftn/100 cfm/100 ElComplies [F1411 cfm/100 fl:2 across the system or ft2 ft2 E]Does Not < =3 cfm/100 ft2 without air E]Not Observable handier @ 25 Pa. For rough -in 'tests, EINot Applicable verification may need to !occur during Framing Inspection. 403.2.2.1 Air handler leakage designated Elcomplies [F124]1 by manufacturer at <=2% of E]Does Not design air flow. EINot Observable EINot Applicable 403.1.1 Programmable thermostats ElComplies [F19]2 installed on forced air furnaces. E]Does Not 14 [:]Not Observable E]Not Applicable 403.1.2 Heat pump thermostat installed ElComplies [FlJ0]2 on heat pumps. E]Does Not 10) E]Not Observable E]Not Applicable 403.4.1 'Circulating service hot water ElComplies [F11 1]2 systems have automatic or E]Does Not 14 accessible manual controls. EJNot Observable E]Not Applicable 403.5.1 All mechanical ventilation system ElComplies [F125]2 fans not part of tested and listed E]Does Not HVAC equipment meet efficacy E]Not Observable and air flow limits. E]Not Applicable 404.1 75% of lamps in permanent 'FIComplies [F1611 fixtures or 75% of permanent []Does Not fixtures have high efficacy lamps. E]Not Observable Does not apply to low -voltage EJNot Applicable lighting. 111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 3 1 Low lmpac7t7(7T7i e�r �3) Project Title: 150527 — Trust — Merrimac_BldgG—UnitG4—ModelB Report date: 05/27/15 Data filename: S:\Ebbeling - Ed\150507—Trust — MerrimacConc1os_BldgG_Un1tsl3B- Page 8 of 9 BB—NAndover\Rescheck\l��0527—Trust—Merrimac—BidgG�_UnitG4—ModelB.rck Section # Final Inspec � tion Provisions Plans Verified Value Field Verified Value ComplieS7 Comments/Assumptions & Req.113 404.1.1 Fuel gas lighting systems have ElComplies [F[23]3 no continuous pilot light. E]Does Not [-]Not Observable EINot Applicable 401.3 Compliance certificate posted. ElComplies [F1712 E]Does Not EINot Observable EINot Applicable 303.3 Manufacturer manuals for ElComplies [F[18]3 mechanical and water heating E]Does Not !systems have been provided. E]Not Observable EINot Applicable Additional Comments/Assumptions: 111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) 1 Project Title: 150527 — Trust — Merrimac — BIdgG — UnitG4 — ModelB Report date: 05/27/15 Data filename: S;\Ebbeling Ed\150507—Trust MerrimacCondos—BidgG—UnitsBB- Page 9 of 9 BB—NAndover\Rescheck\l�-0527—Trust—Merri—mac—BidgG_UnitG4—ModelB.rck i 2012 �ECC Energy Effidency CerVflcate Above -Grade Wall 21.00 Below -Grade Wall 0.00 Floor 30.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Window 0.29 Door 0.29 Comments c3l a c33o c34 c35 m /co..... . .... 0 0 CERTIFIED PLOT PLAN =MBWY U= me ommmm "" am M= mi Im M"Mvm WWM RAW nR TM K&W TW MOMTM #3 SHMM 0= SW VWLA'm my amm PSMZM*m mmoomm tnwcnm to Few" IV Lim �,qj -4F*v 0 -43�Mv -Nam .7 -& 7 - .", 6w, 107 - Af 12-9. -. , , 1: 'Ain1wi, W I kijw�"' PAro= e,,wmwm pts F -A! r t AL 67 b C39 75. F All 4z l--'/ $0, C4C 0- c 41 lro owwwm"jcwh cm Nummm Yuan= Imal 2 mw in ntm WWWWAY. w Cm "3=& ow a Lora 10W - 03 FOUNDATION.AS-BUILT.BUILDING."G* MERRIMAC CONDOMINIUMS ROUTE 114.. NORTH ANDOVER, MASS. PR[UECT NO NAND13 SCAM 1'=4(r DRAVN BYs PCG DATE, 5/1/15 CHECKED BYvSC SHT& I REVISED Wo I 2 Massachusetts - Department of Public Safety Board of Building Regulations and Standards Construction Supervisor License: CS -05M9 T11MO1HY M BAOLOYY., P.O. BOX # 12 South Grafton MA 01S6 0 T ww"N Expiration Commissioner 01124/2016 S—\ Office of Consumer Affairs & Business Regulation ME IMPROVEMENT CONTRACTOR -43758 gistration: Type: xpiration: , 7/2k616, DBA U � -- * BARLOW BUILDING9',1SF�------. TIM BARLOW 13 DEPOT ST S. GRAFTON, MA 0156 Undersecretary VP Kanayo Lala, P.E . ............. 03/03/2014 PROJECT: Merrimack Condominiums G -TYPE BB -Compass Point, N Andover, MA DESIGN FOR - GIRDERSMOISTS /RAFTERS Third Floor Beam T1 Supporting Floor, Wall, Affic & Point Load From T5 LOADS: DEAD LOAD 22.54 PSF 323.00 PLF Ce= 1 CF= 1.00 SNOW LOAD PSF 0.00 PLF Cq= 1 Cs= LIVE LOAD 30.00 PSF 429.90 PLF qs= 29.10 Cd= I TOTALLOAD 753 PLF I= 1 Crn=1 WIND SPEED 100 MPH 29.10 PSF POINT LOAD 3510 LBS 3.25 FT Ra= 2925 LBS 7341 LB =TOTAL REACTION TRIBUTARYWIDTH 14.33 LF E= 2000000 PSI JOIST/GIRDER SPAN 19.5 LF Fb= 2900 PSI WIDTH- IN 10.50 PSL/LVL 11.875 IN = d Fv= 285 PSI ROOF PITCH - N:12 Fc= 2700 PSI Fcp= 750 PSI MOMENT= 35786 LB -FT MOMENT2= 9506 LB -FT 246.78 =S provided OK S= 187.42 IN A 3 1465.24 = I Deflection 0.836 IN = U 240 For Total Load Required 1-1240 Deflection2 0.139 IN = U 421 For Live Load Required 1-1360 Fcp'= 652 PSI OK 1.50 In Bearing Length Fv'= 123 PSI OK USE BETTER HEADER#65 (FLITCH BEAM) 2-LVLs 11 7/8" WITH 1/2"STEEL PLATE BOLTED WITH 5/8"DIA@12"O.C. IN TWO ROWS. or KWYO H. LALA No. 3371" ST Kanayo Lala, P.E . ............. 03/03/2014 PROJECT: Merrimack Condominiums G -TYPE BB -Compass Point, N Andover, MA 14 DESIGN FOR - GIRDERSMOISTS /RAFTERS Third Floor Beam T2 Supporting Floor, Wall & Attic LOADS: DEAD LOAD 22.54 PSF 322.95 PLF Ce= 1 CF= 1.00 SNOW LOAD PSF 0.00 PLF Cq= 1 Cs= LIVE LOAD 30.00 PSF 429.90 PLF qs= 29.10 Cd= 1 TOTALLOAD 753 PLF I= I CM=1 WIND SPEED 100 MPH 29.10 PSF POINT LOAD LBS FT Ra= 0 LBS 6211 LB =TOTAL REACTION TRIBLITARYWIDTH 14.33 LF E= 2000000 PSI JOIST/GIRDER SPAN 16.5 LF Fb= 2900 PSI WIDTH- IN 7.00 PSULVL 11.875 IN = d Fv= 285 PSI ROOF PITCH - N:12 Fc= 2700 PSI Fcp= 750 PSI MOMENT= 25620 LB -FT MOMENT2= 0 LB -FT 1164.52 =S provided OK S= 106.02 IN A 3 976.83 = I Deflection 0.643 IN = U 308 For Total Load Required U240 Deflection2 0.000 IN = L/ 540 For Live Load Required U360 Fcp'= 592 PSI OK 1.50 In Bearing Length Fv'= 112 PSI OK KANAY0 LALA NO. .33710-C Kanayo Lala, RE . ............. 03/03/2014 PROJECT: Merrimack Condominiums G -TYPE BB -Compass Point, N Andover, MA DESIGN FOR - GIRDERSMOISTS /RAFTERS Third Floor Beam T3 Supportinq Floor & Point Load From TI& T2 LOADS: DEAD LOAD 20.00 PSF 360.00 PLIF Ce= 1 CF= 1.00 SNOW LOAD PSF 0.00 PLF Cq= I Cs= LIVE LOAD 30.00 PSF 540.00 PLIF qs= 29.10 Cd= 1 TOTALLOAD 900 PLF I= 1 Crn=1 WIND SPEED 100 MPH 29.10 PSF POINT LOAD 16477 LBS 3.25 FT Ra= 13327 LBS 7650 LB =TOTAL REACTION TRIBUTARY WIDTH 18.00 LF E= 2000000 PSI JOIST/GIRDER SPAN 17 LF Fb= 2900 PSI WIDTH- IN 14.00 PSULVL 11.875 IN = d Fv= 285 PSI ROOF PITCH - N:12 Fc= 2700 PSI Fcp= 750 PSI MOMENT= 32513 LB -FT MOMENT2= 43313 LB -FT 329.04 =S provided OK S= 313.76 IN A 3 1953.65 = I Deflection 0.433 IN = L/ 252 For Total Load Required U240 Deflection2 0.378 IN = L/ 419 For Live Load Required L/360 Fcp'= 499 PSI OK 3.00 In Bearing Length Fv'= 189 PSI OK r"A" "� OF USE BETTER HEADER#84 (FLITCH BEAM) 3-LVLs 11 7/8" WITH 2-3/8" STEEL PLATE OF w Ct t BOLTED WITH 5/8" DIA @ 12-O.C. IN TWO ROWS. AW; -1 USE 2-LVLs 11 7/8" FOR BEAM T4. 1�� It Kanayo Lala, RE . ............. 03/03/2014 PROJECT: Merrimack Condominiums G -TYPE BB -Compass Point, N Andover, MA DESIGN FOR - GIRDERSMOISTS /RAFTERS Third Floor Beam T3 -STEEL Suw)ortina Floor & Point Load From TI& T2 LOADS: DEAD LOAD 20.00 PSF 360.00 PLF Ce= 1 CF= 1.00 SNOW LOAD PSF 0.00 PLF Cq= 1 Cs= LIVE LOAD 30.00 PSF 540.00 PLF qs= 29.10 Cd= 1 TOTALLOAD 900 PLF I= 1 Crn=1 WIND SPEED 100 MPH 29.10 PSF POINT LOAD 16477 LBS 3.25 FT Ra= 13327 LBS 7650 LB =TOTAL REACTION TRIBUTARY WIDTH 18.00 LF E= 29000000 PSI JOIST/GIRDER SPAN 17 LF Fb= 24000 PSI WIDTH- IN 6.50 36KSI W1 2X30 12.34 IN = d Fv= 16200 PSI ROOF PITCH - N:12 Fc= 24000 PSI Fcp= 405 PSI MOMENT= 32513 LB -FT MOMENT2= 43313 LB -FT 38.60 =S provided OK S= 37.91 IN A 3 210.00 =I Deflection 0.278 IN = U 392 For Total Load Required L/240 Deflection2 0.242 IN = U 654 For Live Load Required U360 Fcp'= 359 PSI OK 9.00 In Bearing Length Fv'= 10,200 PSI OK W12X30, DEPTH=12.34" AND FLANGE WIDTH=6.5". USE 2-LVLs 11 7/8 "FOR BEAM T4. ( r..t= Kanayo Lala, RE . ............. 03/03/2014 PROJECT: Merrimack Condominiums G -TYPE BB -Compass Point, N Andover, MA DESIGN FOR - GIRDERSMOISTS /RAFTERS Third Floor Beam T5 Sutmortina Floor & Wall LOADS: DEAD LOAD 24.00 PSF 240.00 PLF Ce= 1 CF= 1.00 SNOW LOAD PSF 0.00 PLF Cq= 1 Cs= LIVE LOAD 30.00 PSF 300.00 PLF qs= 29.10 Cd= 1 TOTALLOAD 540 PLF 1= 1 Cm=1 WIND SPEED 100 MPH 29.10 PSF POINT LOAD LBS FT Ra= 0 LBS 3510 LB =TOTAL REACTION TRIBLITARYWIDTH 10.00 LF E= 2000000 PSI JOIST/GIRDER SPAN 13 LF Fb= 2900 PSI WIDTH- IN 3.50 PSL/LVL 11.875 IN = d Fv= 285 PSI ROOF PITCH - N:12 Fc= 2700 PSI Fcp= 750 PSI MOMENT= 11408 LB -FT MOMENT2= 0 LB -FT 82.26 =S provided OK S= 47.20 IN A 3 488.41 =I Deflection 0.355 IN = L/ 439 For Total Load Required U240 Deflection2 0.000 IN = L/ 790 For Live Load Required L/360 Fcp'= 669 PSI OK 1.50 In Bearing Length Fv'= 127 PSI OK ALSO USE 3-LVLs 117/8" FOR BEAM T6. KANAYO H. LALA No. 33710-C Kanayo Lala, P.E . ............. 03/03/2014 PROJECT: Merrimack Condominiums G -TYPE BB -Compass Point, N Andover, MA DESIGN FOR - GIRDERSMOISTS /RAFTERS LOADS: DEAD LOAD 24.00 PSF SNOW LOAD PSF LIVE LOAD 40.00 PSF TOTALLOAD WIND SPEED 100 MPH POINT LOAD LBS Ra= 0 LBS TRIBLITARYWIDTH 10.00 LF JOIST/GIRDER SPAN 13 LF WIDTH- IN 3.50 PSL/LVL 11.875 ROOF PITCH - N:12 = N 2nd Floor Beam S1 Supporting Floor & Wall 240.00 PLF Ce= 1 0.00 PLF Cq= 1 400.00 PLF qs= 29.10 640 PLF I= 1 29.10 PSF FT 4160 LB =TOTAL REACTION E= 2000000 PSI Fb= 2900 PSI IN = d Fv= 285 PSI Fc= 2700 PSI Fcp= 750 PSI CF= 1.00 Cs= Cd= 1 Cm= 1 MOMENT= 13520 LB -FT MOMENT2= 0 LB -FT 82.26 =S provided OK S= 55.94 IN A 3 488.41 =I Deflection 0.421 IN = U 371 For Total Load Required L/240 Deflection2 0.000 IN = U 593 For Live Load Required U360 Fcp'= 396 PSI OK 3.00 In Bearing Length Fv'= 150 PSI OK OF VANA NO. 3- Kanayo Lala, P.E . ............. 03/03/2014 PROJECT: Merrimack Condominiums G -TYPE BB -Compass Point, N Andover, MA DESIGN FOR - GIRDERS/JOISTS /RAFTERS 2nd Floor Beam S2 Supporting Floor & Point Load From S1 LOADS: DEAD LOAD 15.00 PSF 19.95 PLF Ce= 1 CF= 1.00 SNOW LOAD PSF 0.00 PLF Cq= 1 Cs= LIVE LOAD 40.00 PSF 53.20 PLF qs= 29.10 Cd= 1 TOTALLOAD 73 PLF I= 1 Crn=1 WIND SPEED 100 MPH 29.10 PSF POINT LOAD 4160 LBS 3.25 FT Ra= 3467 LBS 713 LB =TOTAL REACTION TRIBLITARYWIDTH 1.33 LF E= 2000000 PSI JOIST/GIRDER SPAN 19.5 LF Fb= 2900 PSI WIDTH- IN 3.50 PSULVL 11.875 IN = d Fv= 285 PSI ROOF PITCH - N:12 Fc= 2700 PSI Fcp= 750 PSI MOMENT= 3477 LB -FT MOMENT2= 11267 LB -FT 82.26 =S provided OK S= 61.01 IN A 3 488.41 = I Deflection 0.244 IN = U 318 For Total Load Required 1-1240 Deflection2 0.493 IN = U 437 For Live Load Required U360 Fcp'= 398 PSI OK 3.00 In Bearing Length Fv'= 151 PSI OK LALA No. 33710-C Kanayo Lala, RE . ............. 03/03/2014 PROJECT: Merrimack Condominimums G -TYPE -BB -Compass Ponit, N Andover, MA DESIGN FOR - GIRDERS/JOISTS /RAFTERS Garage Door Header S3 Supporting Two Floors, Roof, Wall & Point Load From TI LOADS: DEAD LOAD 73.72 PSF 718.75 PLIF Ce= 1 CF= 0.96 SNOW LOAD 38.50 PSF 375.38 PLF Cq= 1 Cs= LIVE LOAD 70.00 PSF 682.50 PLF qs= 29.10 Cd= 1.15 TOTALLOAD 1777 PLF I= 1 Cm=1 WIND SPEED 90 MPH 29.10 PSF POINT LOAD 4900 LBS 6 FT Ra= 3118 LBS 14657 LB =TOTAL REACTION TRIBUTARY WIDTH 9.75 LF E= 2000000 PSI JOIST/GIRDER SPAN 16.5 LF Fb= 2900 PSI WIDTH- IN 5.25 PSL/LVL 18 IN = d Fv= 285 PSI ROOF PITCH - N:12 Fc= 2700 PSI Fcp= 750 PSI MOMENT= 60461 LB -FT MOMENT2= 18709 LB -FT 350.00 =S provided OK S= 284.87 INA3 2228.94 = I Deflection 0.665 IN = L/ 240 For Total Load Required U240 Deflection2 0.160 IN = U 403 For Live Load Required U360 Fcp'= 677 PSI OK 5.00 In Bearing Length Fv'= 245 PSI OK USE 2-LVLs 11 7/8" FOR BEAM S4. /4� M9 KANAYO LALA, P.E ........ . 03/03/2014 SPECIFIC CALCULATIONS FOR THE WOOD CONSTRUCTION IN 10OMPH WIND ZONE 60,62,64 & 66 COMPASS POINT, NORTH ANDOVER, MA BUILDING "G" UNIT G1, G2, G3 & G4 26'X 36' BASIC LOADS: GROUND SNOW LOAD 50 PSF LIVE LOAD 40 PSF WIND LOAD 18 PSF Building Length 36 ft Building Width 26 ft Building Aspect Ratio= 1.38 Building Area 936 sf Shear End Wall= 11,664 224 PLF Building Mean Height 36 ft Shear Long Wall= 8,424 117 PLF Total Height 45 ft Dead Load of Building 65,520 lbs 1/2"A.BOLT SHEAR 801 LB DL Moment End Wall 1,179,360 LB -FT 4 FT SPACING FOR 1/2" A.BOLTS DL Moment Long Wall 851,760 LB -FT WITH TWO 2X SYP PLATES NET Wind Moment End Wall 209,952 End Wall M -969408 NO UPLIFT Wind Moment Long Wall 151,632 Long W M -700128 NO UPLIFT I.E. NO UPLIFT EXISTS AT THE BASE OF THE BUILDING. SHEAR ANCHORS ARE ADEQUTE SHEAR WALL CAPACITY BY TABLE 2306.2.1 (1) 1/2" OSB / CDX PLY WITH 8D NAILS AT 6" ON EDGES AND 6" ON FIELD - 270PLF< 224 PLF REQUIRED FOR THREE STORY HEIGHT- OK SHEAR WALL REQUIREMENT BY TABLE R602.10.1.2(l) 1/2" OSB WITH 6D NAILS AT 6" ON EDGES AND 12" ON FIELD PER TABLE R602.3(3) 13 FT CONTINUOUS SHEATHING AVAILABLE ALONG LONG WALL = 19 FT THE MOMENT SHEAR AT THE OPENINGS IS RESISTED BY THE METAL CONNECTION PLATES AS DETAILED ON THE PLANS. FOR A TYPICAL 6'WIDE OPENING IN END WALL AT 224 PLF SHEAR: AT THE OPENING CORNER 673 LBS. A SIMPSON PC66 POST CAP - LATERAL CAPACITY 1285LBS - OK THE CALCULATIONS ABOVE MEET THE REQUIREMENTS OF THE IRC2009 R602.10 AND 780CMR51 AMENDMENTS TO IRC2009. 7 a ACCORLY CERTIFICATE OF LIABILITY INSURANCE DATE (MMIDDIYYYY) F 2/10/15 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER THIS CER71FICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERrIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policyfies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsemengs). PRODUCER Coonan Insurance Agency, Inc. 267 Main Street Oxford, MAL 01540 CONTACT -NAME: PHONE (508) 987-7122 No): (508) 987-7152 .(AiEN,E,di- F -ArDRELSS: cindv@coonaninsurance.com 680-335M1703-14 11/3/14 INSURE R(S) AFFORDING COVERAGE NAIC 0 INSURER A - Travelers DAMAGE TO RENTED rence) $ 300,000 INSURED _ PERSO NA L & ADV I NJURY $ 11000,000 TJK, Inc. _INSURERB: INSURERC: PO Box 12 INSURERD: South Grafton, MA 01560 INSURER E * I I NSURER F: I i COVERAGES CERTIFICATE N UMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LT TYPE OF INSURANCE AML 1M SUBR WvD POLICY NUMBER POLICY EFF tMMIDDNYYY) POLICY OW (MMIDD1YYYY) LIMITS A GENERAL LIABILITY X COMMERCIAL GENERALLIABILITY CLAIMS-MADEFx ]OCCUR Cindy Davis 680-335M1703-14 11/3/14 11/3/15 EACH OCCURRENCE $ 1,000,000 DAMAGE TO RENTED rence) $ 300,000 ME D OF (A . ny one person) $ 5,000 _ PERSO NA L & ADV I NJURY $ 11000,000 GENERAL AGGREGATE $ 2,000,000 GEN'LAGGREGATE LIMITAPPLIES PER PRO- LOC _X1 POLICY FIXCT [PRODUCTS - ODMPA:)P AGG $ 2,000,000 $ AUTOMOBILE LIABILITY ANYAUTO ALLOWNED SCHEDULED AUTOS AUTOS NON -OWNED HIREDAUTOS — AUTOS '0 EDSINGLELIMIT (E,T,"d.r,) $ BODILY INJURY (Per person) $ BODILY INJURY (Per accident) $ PROPERTY DAMAGE P.r..dnt) $ UMBRELLA LIAB EXCESSUAB OOCUR CLAIMS -MADE EACH OCCU ENCE $ AGGREGATE $ DED RETENTION $ $ A WORKERS COMPENSATION AND EMPLOYERS' LIABILITY YIN ANY PROPRIETOR/PARTNERIEXECUTIVE OFFICERIMEMBER EXCLUDED? 7N (Mandatory In NH) If yes, describe under I DESCRIPTION OF OPERATIONS below NIA IE -UB -9914N01-3-15 1/26/15 1/26/16 C ATU- OTH- X I TWIIFIYSTL,M.Tq I PP E.L. EACH ACCI DENT $ 100,000 E.L. DISEASE -EA EMPLOYEE $ 100,000 E.L. DISEASE - POLICY LIMIT $ 500,000 OESCRIIPTION OF OPERATIONS I LOCATIONS I VEHICLES (Aftitch ACORD V", Additional Refferks Schedulle, N nwre space Is recItilmd) CERTIFICATE HOLDER CANCELLATION @ 1988-20 10 ACORD CORPORATION. All rights reserved. ACORD 25 (2010105) The ACORD name and logo are registered marks of ACORD Phone: Fax: E -Mail: tdbuilding@aol.com SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Town of North Andover ACCORDANCE WITH THE POLICY PROVISO NS. 120 Main Street AUTHORIZED REPRESENTATIVE North Andover, MA 01845 Cindy Davis @ 1988-20 10 ACORD CORPORATION. All rights reserved. ACORD 25 (2010105) The ACORD name and logo are registered marks of ACORD Phone: Fax: E -Mail: tdbuilding@aol.com