Ut,GK11' 11UN OF WUKK TO BE PREFORMED:
interior renovation to include carpentry, painting, plumbing, electrical,finish
flooring and drywall.
Identification Please Type or Print Clearly)
OWNER: Name: ''SP9P_acl1 t -_ w W P alff=. [-,LC-Phone: (Qag) U,0 -()C
VAN
ARCHITECT/ENGINEER RHC Professional Association Phone: (603) 465-7133
Address: 76 Wright Rd -Hollis, NH 03049 Reg. No. 2020
FEE SCHEDULE: BULDING PERMIT: $12A0 PER $1000.00 OF THE TOTAL ESTIMATED COST BASED ON $125.00 PER S.F.
Total Project Cost: $ 261,000. FEE: $_/l
Check No.: ��- Receipt No.:
NOTE: Persons contractingth nlgis d contract do not have access to the guaranty fund
Plans Submitted Plans Waived Certified Plot Plan =Stamped
TYPE OF SEWERAGE DISPOSAL
V,
Public Sewe
Tanning/Massage/Body Art
r t ea
Swimming Pools
Well
Tobacco Sales
Food Packaging/Sahs�;
Private (septic tank, etc.
Permanent Dumpster on Site
THE FOLLOWING SECTIONS FOR OFFICE USE ONLY
INTERDEPARTMENTAL SIGN OFF - U FORM
DATE REJECTED DATE APPROVED _
PLANNING & DEVELOPMENT
COMMENTS
CONSERVATION Reviewed on Signature
COMMENTS
HEALTH Reviewed on Signature
COMMENTS
rj
Zoning Board of Appeals: Variance, Petition No: Zoning Decision/receipt submitted yes
Planning Board Decision: Comments
Conservation Decision: Comments
Water & Sewer Connection/Signature & Date Driveway Permit
DPW Town Engineer: Signature:
Dimension
Number of Stories: Total square feet of floor area; based on Exterior dimensions.
Total land area, sq. ft.:
ELECTRICAL: Movement of Meter location, mast or service drop requires approval of
Electrical Inspector Yes No
DANGER ZONE LITERATURE: Yes No
MGL Chapter 166 Section 21A —F and G min.$100-$1000 fine
NOTES and DATA — (For department use)
❑ Notified for pickup - Date
Doc.Building Permit Revised 2008
Building Department
The following is a list of the required forms to be filled out for the appropriate permit to be obtained.
Roofing, Siding, Interior Rehabilitation Permits
❑ Building Permit Application
❑ Workers Comp Affidavit
❑ Photo Copy Of H.I.C. And/Or C.S.L. Licenses.
❑ Copy of Contract
❑ Floor Plan Or Proposed Interior Work
❑ Engineering Affidavits for Engineered products
NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit
Addition Or Decks
❑ Building Permit Application.
❑ Certified Surveyed Plot Plan
❑ Workers Comp Affidavit
❑ Photo Copy of H.I.C. And C.S.L. Licenses
❑ Copy Of Contract
o Floor/Crossection/Elevation Plan Of Proposed Work With Sprinkler Plan And
Hydraulic Calculations (If Applicable)
❑ Mass check Energy Compliance Report (If Applicable)
❑ Engineering Affidavits for Engineered products
NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit
New Construction (Single and Two Family)
❑ Building Permit Application
❑ Certified Proposed Plot Plan
❑ Photo of H.I.C..And C.S.L. Licenses
❑ Workers Comp Affidavit
❑ Two Sets of Building Plans (One To Be Returned) to Include Sprinkler Plan And
Hydraulic Calculations (If Applicable)
❑ Copy of Contract
❑ Mass check Energy Compliance Report
❑ Engineering Affidavits for Engineered products
NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit
In all cases if a variance or special permit was required the Town Clerks office must stamp the decision from the Board of Appeals
that the appeal period is over. The applicant must then get this recorded at the Registry of Deeds. One copy and proof of recording
must be submitted with the building application
Doc: INSPECTIONAL SERVICES DEPARTMENT:BPFORM07
Revised 2.2008
Location v
No. ( Date
NORTH
TOWN OF NORTH ANDOVER
t - s
W
Certificate Occupancy
�o ,• .
of $
._�,_.. .
","°
sACHUSt
Building/Frame Permit Fee $—
Foundation Permit Fee $
Other Permit Fee $
TOTAL $
Check # s'
2 (I 87
Building Inspector
Gel ina5 %ruderal Fngineerinq LLC Phone 978.465.6436
Daniel L. Gelinas, P.E. Fax Line : 978.465.5160
579A North End Blvd,
Salisbury, MA 01952-1738 email danl�elinas(c O—Mcast.nct
June 5, 2008
Joe Levis, Levis Companies, 111c.
160 Pleasant Street
North Andover, MA 01845StTBJECT:
Subject:
Enclosures
Dear Mr. Levis:
fax 978.687.3042
phone 2783
levisco ,verizon.net
5 Village Way, North Andover, MA
You have requested Gelinas Structural Engineering LLC (GSE) to review and comment regarding three
LVL beams at the above address. On 6-5-09 GSE met you on site, m3dc structural observations, etc.
Reference enclosed Ivey Plan SKSCY-1 for Second Floor Framing LVL beams B21, B22, and 823. The
results of our observations are as follow:5:
All three LVL beams satisfy the code requirements of the Massachusetts Sate Building Code O Edition
Chapter 36 One and Two Family Dwellings as well as the Massachusetts State Building Code 7`h Edition
One and Two family Dwellings
Please call all with any questions.
very truly yours,
!D.i2A*n , .
C setter 08088 5 Village Way.doc
0
DANIEL L.
GELINAS
STRUCTURAL
No. 33094
GELINAS STRUCTURAL ENGINEERING LLC SHEET NOof-
579A North End Blvd.
Salisbury, MA 01952-1738 °ArE�
Phone: 978.485.6436 (Fax 5160)
e-mail: danigelinas@adelphia.net J0B
e � Ali
E�
DANIEL Lr G
C-,ELINAS
STRUCTURAL -----
No. 33994
�iconVr. � < ,,• f4i� RS C'S3STA�NJ!''.v �., r.... .
_ � � f.a..:�•i 15x�s�.. r.
UIt _! Ll U(1 !I L.i IIIf i!_ I L'_I22, <�, A4_.'A1 G -e
,
a
tY ,,.1..1u:» 4 RCS Of 1314" x 24" 4.0*PE Microllam@ LVL
TJ -Been,® 6.30 Serif NtMr. 70M121073
Uswr2 b151200e01.22.30PM THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN
Page 1 Engine Vehion: 6.30.14
CONTROLS FOR THE APPLICATION AND LOADS LISTED
F1I
PFOdUCt Diagram is Coiij4e ual.
LOADS:
Analysis is for a Drop Beam Member.
Tributary Load Width; 14'
Primary Load Group - Residential -
Living Areas (psf): 40.0 Live at 100 % duration, 12.0 Dead
SUPPORTS:
Input Bearing
Vertical Reactions (lbs) Detail Other
Width Length
LivelDeadltlplittlTotal
1 Stud wall 3.50" .. 3.12"
6720125731019293 -- L1: Blocking Custom Blocking
2 Stud wall 3.50" 3.12"
6720 12573 1 0 / 9293 Lf: Blocking Custom Blocking
-See iLevelO Specifter'slBuilder's Guide for detail(s): L1: Blocking
DESIGN CONTROLS:
Maxlmumri
Design Control Result Location
Shear (lbs) 8164
-7518 31920 Passed (24%) Rt. and Span 1 under Floor loading
Moment (Ft -Lbs) 54219
54219 132502 Passed (41%) MID Span 1 under Floor loading
Live Load Defl,(in)
0.286 0.789 Passed (L1992) MID Span 1 under Floor loading
Total Load Deft (in)
0,396 1.183 Passed (11717) MID Span 1 under Floor loading
DANIEL L.
GELINAS
STRUCTURAL
No. 33994
-Deflection Criteria: STANDARD(LL:U360,TL:L1240).
-Bracing(Lu): All compression edges (top and bottom) must be braced at 16' o1c unless detailed otherwise. Proper attachment and positioning of lateral
bracing is required to achieve member stability.
ADDITIONAL NOTES-
-IMPORTANT! The analysis presented is output from software developed by iLevelO. iLeveI8 warrants the sizing of its products by this software will
be accomplished in accordance with iLevei* product design criteria and code accepted design values. The specific product application, input design
loads, and stated dimensions have been provided by the software user. This output has not been reviewed by an it-evelt Associate.
-Not all products are readily available. Check with your supplier or iLevela technical representative for product availability.
-THIS ANALYSIS FOR iLOVel@ PRODUCTS ONLY! PRODUCT SUBSTITUTION VOIaS THIS ANALYSIS.
-Allowable Stress Design methodology was used for Building Code UBC analyzing the iLevel® Distribution product listed above,
-Note: See iLeveM Specifler'slBuilder's Guide for multiple ply connection.
PROJECT INFORMATION:
.toe Levis, Levis Companies, Inc_
160 Pleasant Street
North Andover, MA 01845
Site 5 Village Way
North Andover, MA
OPERATOR INFORMATION:
Dan L, Gelinas, P.E.
Gelinas Structural Engineering LLC
579A North End Blvd
Salisbury, MA 01952-1738
Phone., (978)465-6436
Fax :(97B)465-5160
danlgelinas@comcast.net
COPY'-! 1)11L ,yV47 Ly iSCVt1M, FQ6(,ral Bay, WA_
M1crol LATIM to q rryietered trcacmark pC LLevc1'&.
1::\v+cvncntz and Sctvngy\pd11 (ielinas%%:jy D.',^1=mHI1Ca\OB_:.LC\UyUUe .Toy l.w;a icr 5 V_11a�7.; Way 14 Aadavnr\t' fill GAragc ba,mr_nrtg
If . V V _ J _ : f' I'vl U d 11 _ 0 C I I I I .1 ;, !' ryL''y./`�a�i ; . `i l, . i i • o) i L.' /h L I !
e '/ ✓` f 11-064 �/
U
w a t
4 Pcs of 1,75" x 21111.9E Microllam@ LVL
TJ-aesmO 6.30 Serial Number. Mai 21073
U31CO 615120066.53:,3Pm THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN
Pegs, Engine Vmgion:fi.3o.14 CONTROLS FOR THE APPLICATION AND LOADS LISTED
�Q
product Diagram is 0onteptual.
LOADS:
Analysis is for a Drop Beam Member. Tributary Load Width: 1'
Primary Load Group - Residential - living Areas (psf): 80.0 Live at 100 % duration, 30.0 meed
Vertical Loads:
Type Class Live Dead Location Application Comment
Point(lbs) Floor(1.00) 10080 4183 V V, -
Uniform(plf) Floor(1.00) 0.0 80.0 0 To 17'6" Adds To
Uniform(plt) Floor(1.00) 40.0 15,0 0 To 17' 6" Adds To
SUPPORTS:
Input Bearing Vertical Reactions (Ibs) Detail Other
Width Length Live/Dead/Upliftfrotal
1 Stud wall 3,50" 3.24"- 60901354010 / 9631 L1: Blocking Custom Blocking
2 Stud wall 3.50" 3,24" 60901354010 1 9631 L1: Blocking Custom Blocking
jjy OF �S
T DANIEL L.
p GELINAS
STRUCTURAL
No. 33M
-See iLevelg) specif'er'sBuiider's Guide for detail(s): L1: Blocking
DESIGN CONTROLS:
Maximum
Design
Control
Result
Location
Shear (lbs) 9583
-9047
27930
Passed (32%u)
Rt. end Span 1 under Floor loading
Moment (Ft -Lbs) 71733
71733
103306
Passed (69%)
MID Span 1 under Floor loading
Live Load Defl (in)
Total Load Defl (in)
0.241
0.367
0,572
Passed (L1855)
MID Span 1 under Floor loading
0.858
Passed (U562)
MID Span 1 under Floor loading
-Deflection Criteria: STANDARD(LL:L/360,TL:L/240).
-Bracing(Lu): All compression edges (top and bottom) must be braced at 9' 9" oic unless detailed otherwise. Proper attachment and positioning of
lateral bracing is required to achieve member stability.
ADDITIONAL NOTES-
-IMPORTANT! The anatysis presented is output from software developed by ii-evel®. iLevel® warrants the sizing of its products by this software will
be accomplished in accordance with iLevelS product design criteria and code accepted design values. The speck product application, input design
loads, and stated dimensions have been provided by the software user, This output has not been reviewed by an iLevel® Associate.
-Not all products are readily available. Check with your supplier or iLevelO technical representative for product availability.
-THIS ANALYSIS FOR iLeve10 PRODUCTS ONLY[ PRODUCT SUBSTITUTION V0I06 THIS ANALYSIS.
-Allowable Stress Design methodology was used for Building Code UBC analyzing the iLevelO Distribution product listed above.
-Note: See iLeveM Specifier's/Builder's Guide for multiple ply connection.
PROJECT INFORMATION:
Joe Levis, Levis Companies, Inc.
160 Pleasant Street
North Andover, MA 01845
Site 5 Village way
North Andover, MA
OPERATOR INFORMATION:
Dan L. Gelinas, P.E.
Gelinas Structural Engineering LLC
579A North End Blvd
Salisbury, MA 01952.1738
Phone:(97a)465-6436
Fax :(978)465-5160
danleelinas@comcasLnet
Capyr!4ht )1 2007 by tr,evt!1o, Federal Way, NA,
MicrILIZV,: 1A a r,g4;tgr,0 trod«nark o: iLavalcy,
C'\DaC=aat. and SeLLingz\Dan GCl!.na3\1'fy DDCUP.=t:\09 T,i.C\080e& Jac Levin rOr 5 Village Way N A,m1,vvcr1e 327 %reader Left FaMl I FL;+cs, SMS
W . . I, _ ` _ _ _ - , Irl L; _I :I _ i I . I L , '1 . _ .. I , _ - I . ,
ry,H:.yc
1 J-90e7l1QD 6.30 Serial Number. ?W5121073 h,l4 Pcs of 1314" x 2411.9E Microllam® LVL
atfrkr
p6ceI Encino9 rsitir•rM THISPRODUCT MEETS OR EXCEEDS THE SET DESIGN
P�„^,e 1 EnQlne V6f8iCre 9.301;
CONTROLS 'FOR THE APPLICATION AND LOADS LISTED
-Deflection Criteria: STANDARD(LL:IJ360,TL:L/240).
-Bracing(Lu): All compression edges (top and bottom) must be braced at 1601c unless detailed otherwise. Proper attachment and positioning of lateral
bracing is required to achieve member stability,
ADDITIONAL NOTES:
-IMPORTANT! The analysis presented is output from software developed by iLevelO. iLevel® warrants the sizing of its products by this software will
be accomplished in accordance with ileveig product design criteria and code accepted design values. The specific product application, input design
loads, and stated dimensions have been provided by the software user. This output has not been reviewed by an iL9velO Associate.
-Not all products are readily available. Check with your supplier or iLeve* technical representative for product availability,
THIS ANALYSIS FOR iLevel® PRODUCTS ONLY! PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS.
-Allowable Stress Design methodology was used for Building Code UBC analyzing the iLevel6 Distribution product listed above.
-Note: See iLeveIV Specifiers/Builders Guide for multiple ply connection.
PROJECT INFORMATION:
Joe Levis. Levis Companies Inc.
160 Pleasant Street
North Andover, MA 01845
Site 5 Village Way
North Andover, MA
OPERATOR INFORMATION:
Dan L. Colinas, P.E.
Colinas Structural Engineering LLC
579A North End Blvd
Salisbury, MA 01952-1738
Phone : (978)465.6436
Fax : (978)465-5160
danigelinas@00mcastnet
Cor,yzight .h 2007 ty iLeva190, Eariaral key, WA,
Micrella:oa� is a r9ra_e,ere. •_radeark of iT,evelli:.
C:\-cuuxentn and ccttingn%nyrt GC?LASE\P:y II'\600du Cos i.aa5p f�+r 5 valagc Way N Acx:oyer\C 9�7 CArage beama.em:
2T
Pfockrct Diagram is ConceptilmiI.
LOADS:
Analysis is for a Drop Beam Member. Tributary Load Width: 14'
Primary Load Group - Residential -
Living Areas (psf): 4410 Live at 100 % duration, 12.0 Dead
'(H OF
SUPPORTS:
Input Bearing
Vertical Reactions (lbs) Detail Other
$O OANIEL L
Width Length
Live/Dead/UpliftlTotal
GELWAS
1 Stud wall 3.50" 3.12"
6720 1 2573 / 019293 L1: Blocking Custom Blocking
c)
STRUCTURAL
04
No. 3 +
o
2 Stud wall 3.50" 3.12"
6720 / 25731018293 L1: Blocking Custom Blocking
See iLeveM 5pecifees/Buildees Guido for detail(s): L1: Blocking
DESIGN CONTROLS:
Maximum
Design Control Result Location
Shear (lbs) 9164
-7518 31920 Passed (24%) Rt end Span 1 under Floor loading
Moment (Ft -Lbs) 54219
54219 132502 Passed (41 %u) MID Span 1 under Floor loading
Live Load Deft (in)
0.286 0.789 Passed (11992) MID Span 1 under Floor loading
Total Load Deff (in)_ ..
0,398 ' 1.183 Passed (1-1717) MID Span I under Floor loading
-Deflection Criteria: STANDARD(LL:IJ360,TL:L/240).
-Bracing(Lu): All compression edges (top and bottom) must be braced at 1601c unless detailed otherwise. Proper attachment and positioning of lateral
bracing is required to achieve member stability,
ADDITIONAL NOTES:
-IMPORTANT! The analysis presented is output from software developed by iLevelO. iLevel® warrants the sizing of its products by this software will
be accomplished in accordance with ileveig product design criteria and code accepted design values. The specific product application, input design
loads, and stated dimensions have been provided by the software user. This output has not been reviewed by an iL9velO Associate.
-Not all products are readily available. Check with your supplier or iLeve* technical representative for product availability,
THIS ANALYSIS FOR iLevel® PRODUCTS ONLY! PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS.
-Allowable Stress Design methodology was used for Building Code UBC analyzing the iLevel6 Distribution product listed above.
-Note: See iLeveIV Specifiers/Builders Guide for multiple ply connection.
PROJECT INFORMATION:
Joe Levis. Levis Companies Inc.
160 Pleasant Street
North Andover, MA 01845
Site 5 Village Way
North Andover, MA
OPERATOR INFORMATION:
Dan L. Colinas, P.E.
Colinas Structural Engineering LLC
579A North End Blvd
Salisbury, MA 01952-1738
Phone : (978)465.6436
Fax : (978)465-5160
danigelinas@00mcastnet
Cor,yzight .h 2007 ty iLeva190, Eariaral key, WA,
Micrella:oa� is a r9ra_e,ere. •_radeark of iT,evelli:.
C:\-cuuxentn and ccttingn%nyrt GC?LASE\P:y II'\600du Cos i.aa5p f�+r 5 valagc Way N Acx:oyer\C 9�7 CArage beama.em:
x
w
Am
0
o
w°
co
a
Cf)w°
Cd
°
w
z
°�°
U
w
°
w
a�4
�a
w
AG
a
W
C2
C/)w
x
°�°
�
m
w
z
�
w
C5
cn
E
cn
c o
m c
cy
o c
c.2
_=
ti.ac
w ev
.� ea
r
Q
v
ca
CL
CO
E.S
m
OS CD
C
O y
t: y 3
♦ m
ccm
v y W
Ece
Aa�L
�: y m m
'coa
:act
m13:9o�
cc C>2
o �o
ui = co
C
•N dL C
0-
LU .® n o,
y a m- ��_
CL= A m mo O` to
4 S C36 m
f
�i" m
i�
u
uJ
rig
O
O
O
O
v
Z co
d
O y
� C
O cm
y O
O �—
y 0t O
m C12
L0 CD
C
CD
O � CD
CD
0 O
_O O d
CL CMQ
c
o-0
cc
v J 'C
= O yO..
C Z �
CL
V y
O C
C
C
c
H
cm
107 Audubon Rcwl
Btidding 1 — Suite 19
Wakefieid, MA 0,1880
Tei, . 781.2x76-1900
>-,.x 781246-0901
Chris Graham
KS Partners, LLC
700 Tech Park Drive / Suite 102
Billerica, MA 01821
North Andover Pediatrics Bid Proposal
800 Turnpike Street
N Andover, MA
Prism Builders, Inc. is pleased to respond to your invitation to submit this construction bid for work
at the above referenced location.
This proposal is based on the following drawings by Wright Interiors: Al & A2 dated 5-4-08, and
A3,A4,A5,A6 dated 5-7-08.
Scope of work / Clarifications to the drawings include:
Demolition: $11,300.
• Removal of all VCT flooring and carpet, selective wall demo per plans
• Removal of ceiling grid & the in open areas
Doors/Frames: $15,000.
• Supply & install new paint grade doors & H.M. frames to match existing
• Supply & install new door lever hardware at all existing and new doors
Millwork $39,575.
■ Supply & install per plans
Glass: $ 3,000.
■ New sidelight at entry door, new pass-thru glass at check-in area
Drywall: $31,900.
• New drywall partitions (thru ceiling) per plans (insulated at exam rooms)
Acoustical Ceilings: $12,100.
■ Supply & install new 2x4 grid & Cortega ceiling tile throughout most
of the space, otherwise patch & repair in certain areas
Flooring: $17,000.
• Supply & install new carpet and VCT throughout the space ($18/SY allowance)
Painting: $ 8,700.
• Paint (2) coats latex eggshell on all existing walls, (2) coats semi -gloss on
doors & frames, prime & paint (2) coats on new walls
107 Au„1ubor. Road
6iA(ing ' — Site 19
Wa0,?fie:!d. MA 01880
TeL 7fit'?4fr1900
Fax 781%24& 0001
HVAC: (revised scope per Merrimack quote dated 5-12-8) $13,995.
• Install (3) bathroom exhaust systems including fan's, ductwork and roofwork
• Installation of (2) duct distribution systems using a portion of the existing ductwork
• Insulation of all duct distribution systems
Electrical: $34,450.
• Relocate existing lights as needed, convenience power & switching in new offices.
• Upgrade fire alarm & life safety equipment
• Power wire new rooftop units and bathroom exhausts
• Replace ballasts & relamp (88 lights)
• CATS wiring
Sprinkler: $ 4,500.
• Relocate existing sprinkler heads as needed to accommodate new walls
Plumbing: $35,350.
• Supply & install new sinks and bathrooms per plan
Building Permit $ 3,130.
General Conditions & Fee $31,000.
TOTAL COST:
Clarifications:
1. Toilet room specialties included (grab bars, mirrors)
2. Work performed during normal business hours
(portion of demo / first floor plumbing off hours)
Exclusions:
1. Appliances
2. Architectural/engineering fees
3. Removal of hazardous material
$261,000.
F!
North Andover Pediatrics 800 Technology Street North Andover.
Code Analysis May 5, 2008 By RHC Professional Association
Analysis Based on Mass Sixth Edition State Building Code Page 1
Occupancy of the building shall consist of tenants in
Use Group "B" Business only. The Building shall be
classified as Type 2 Unprotected 2C
1. Section 304.0 Business Use Grou
Section 304.1 General: All building and structures which
are occupied for the transaction of business, for the
rendering of professional services, or for other services
that involve stocks of goods, wares or merchandise in
limited quantities which are incidental to office
occupancies or sample purposes shall be classified as Use
Group B.
2. TABLE 503 - Height and Area Limitations of Buildings
b. B Business
Noncombustible Construction Type 2 Unprotected 2C
Height 3 stories 40' Area 14,400 sq.ft.
d. Actual area of building per floor = 17,480 Sq. Ft.
3. Section 506.0 Area Modifications
a. Section 506.1 General: The provisions of 780 CMR 506.0
shall modify the area limitations of Table 503 as
.herein specified.
b. Section 506.2 Street frontage increase: Where a
building or structure has more than 250 of the building
perimeter fronting on a street or other unoccupied
space, the area limitations specified in Table 503
shall be increased 2% for each 1% of such excess
frontage. The unoccupied space shall be on the same lot
or dedicated for public use, shall not be less than 30
feet in width and shall gave access from a street by a
posted fire lane not less than 18 feet in width.
100% of exterior perimeter wall is accessible
Area can be increased 100 - 25 = 75 x 2% = 1.50
C. Section 506.3 Automatic sprinkler system: Where a
building, other than those with an occupancy in Use
Group H-1, H-2 or H-3, is equipped throughout with an
automatic sprinkler system installed in accordance with
780 CMR 906.2.1, the area limitation specified in Table
503 shall be increased 200% for one -and two-story
buildings and 100% for buildings more than two stories
in height.
1
M1
5.
10
North Andover Pediatrics 800 Technology Street North Andover.
Code Analysis May 5, 2008 By RHC Professional Association
Analysis Based on Mass Sixth Edition State Building Code Page 2
Section 506.0 The allowable building area increase by code
between firewalls:
l.Table 503.0 (Noted above) 1.0
2. Section 506.3 (Noted above) 1.5
3. Section 506.4 (Noted above) 1.0
3.5
Allowable area increase 3.5 x 14,400 = 50,400 Sq. Ft.
Actual gross building floor area = 17,480 Sq. Ft.
TABLE 602 Fireresistance ratings of structural elements (In
hours):
Type
2 Unprotected 2C
Rating
A.
Fire Enclosure of
Stairways
2
HRS
B.
Fire Enclosure of
Firewalls
2
HRS
C.
Exitway Access
Corridors
0
HRS
(Table 1011.4 with
Fire Suppression)
D.
Structural Members
Supporting Wall
0
HRS
E.
Floor Construction
Including Beams
0
HRS
F.
Column and Girders
0
HRS
G.
Roof Construction
15' or less
to lowest member
0
HRS
Roof Construction
15' or more but
less than 20'
0
HRS
Roof Construction
15' or more but
less than 20'
0
HRS
Section 603.0 Types 1 and 2 Construction:
a. Section 603.1 General: Buildings and structures of
Types 1 and 2 construction are those in which the
walls, partitions, structure elements, floor, ceilings,
roofs and exits are constructed of approved
noncombustible materials. Each structure element shall
not be less than the required fireresistance rating
specified in Table 602, except as otherwise
specifically provided for a 780 CMR. Buildings of Types
1 and 2 construction shall be further classified as
Type 1A, 1B,2A, 2B, or 2C. Fireretardant-treated wood
shall only be used as specified in Table 602 and 780
CMR 2310.0
N
North Andover Pediatrics 800 Technology Street North Andover.
Code Analysis May 5, 2008 By RHC Professional Association
Analysis Based on Mass Sixth Edition State Building Code Page 3
7. Section 1008.0 Occupant Load
a. Design occupant load: In determining required
facilities, the number of occupants for whom exit
facilities shall be provided shall be established by
the largest number computed in accordance with 780 CMR
1008.1.1 through 1008.1.3.
b. Section 1008.1.1 Actual number: The actual number of
occupants for whom each occupied space, floor or
building is designed.
c. Section 1008.1.2: Number by Table 1008.1.2: The number
of occupants computed at the rate of one occupant per
unit of area as prescribed in Table 1008.1.2.
Table 1008.1.2 Occupancy Floor area in
sq.ft. per occupant
Business "B" 100 gross
d. Section 1008.1.3 Number by combination: The number of
occupants of any space as computed in 780 CMR 1008.1.1
or 1008.1.2 plus the number of occupants similarly
computed for all spaces that discharge through the
space in order to gain access to exit.
8. Section 1006.5 Length of Travel: All exits shall be so
located that the maximum length of exit accesss travel,
measured from the most remote point to an approved exit
along the natural and unobstructed line of travel, shall
not exceed the distances given in Table 10056.5
Table 1006.5 Length of Exit Access Travel
Use Group With Sprinkler System (Feet)
Business "B" 250 feet
9. Section 1009.0 Capacity of Egress Components:
a. Section 1009.2 Minimum width: The width of each means
of egress component shall not be less than the width
computed in accordance with Table 1009.2 for the
required capacity of the component, but not less than
the minimum width as prescribed by 780 CMR for each
such component.
North Andover Pediatrics 800 Technology Street North Andover.
Code Analysis May 5, 2008 By RHC Professional Association
Analysis Based on Mass Sixth Edition State Building Code Page 4
b. Table 1009.2 Egress Width Per Occupant
Use Group With sprinkler system
(inches per person)
Stairways Doors Ramps &
Business "B"
0.2
0.15
10. Section 1010.0 Number of Exits
a. Section 1010.2 Minimum number: Every floor area shall
be provided with the minimum number of approved
independent exits are required in Table 1010.2 based
on the occupant load, except as modified in 780 CMR
1010.3.
b. Table 1010.2 Minimum Number of Exits for Occupant Load
Occupant Load Minimum number of exits
500 or less 2
END OF CODE ANALYSIS
North Andover Pediatrics 800 Technology Street North Andover.
Code Analysis May 5, 2008 By RHC Professional Association
Analysis Based on Mass Sixth Edition State Building Code Page 1
Occupancy of the building shall consist of tenants in
Use Group "B" Business only. The Building shall be
classified as Type 2 Unprotected 2C
1. Section 304.0 Business Use Grou
Section 304.1 General: All building and structures which
are occupied for the transaction of business, for the
rendering of professional services, or for other services
that involve stocks of goods, wares or merchandise in
limited quantities which are incidental to office
occupancies or sample purposes shall be classified as Use
Group B.
2. TABLE 503 - Height and Area Limitations of Buildings
b. B Business
Noncombustible Construction Type 2 Unprotected 2C
Height 3 stories 40' Area 14,400 sq.ft.
d. Actual area of building per floor = 17,480 Sq. Ft.
3. Section 506.0 Area Modifications
a. Section 506.1 General: The provisions of 780 CMR 506.0
shall modify the area limitations of Table 503 as
.herein specified.
b. Section 506.2 Street frontage increase: Where a
building or structure has more than 250 of the building
perimeter fronting on a street or other unoccupied
space, the area limitations specified in Table 503
shall be increased 2% for each 10 of such excess
frontage. The unoccupied space shall be on the same lot
or dedicated for public use, shall not be less than 30
feet in width and shall gave access from a street by a
posted fire lane not less than 18 feet in width.
1000 of exterior perimeter wall is accessible
Area can be increased 100 - 25 = 75 x 20 = 1.50
C. Section 506.3 Automatic sprinkler system: Where a
building, other than those with an occupancy in Use
Group H-1, H-2 or H-3, is equipped throughout with an
automatic sprinkler system installed in accordance with
780 CMR 906.2.1, the area limitation specified in Table
503 shall be increased 200% for one -and two-story
buildings and 100% for buildings more than two stories
in height.
North Andover Pediatrics 800 Technology Street North Andover.
Code Analysis May 5, 2008 By RHC Professional Association
Analysis Based on Mass Sixth Edition State Building Code Page 2
4. Section 506.0 The allowable building area increase..by code
between firewalls:
S.
1.Table 503.0 (Noted above) 1.0
2. Section 506.3 (Noted above) 1.5
3. Section 506.4 (Noted above) 1.0
3.5
Allowable area increase 3.5 x 14,400 = 50,400 Sq. Ft.
Actual gross building floor area = 17,480 Sq. Ft.
TABLE 602 Fireresistance ratings of structural elements (In
hours):
Type 2 Unprotected 2C
A. Fire Enclosure of Stairways
B. Fire Enclosure of Firewalls
C. Exitway Access Corridors
(Table 1011.4 with Fire Suppression)
D. Structural Members Supporting Wall
E. Floor Construction Including Beams
F. Column and Girders
G. Roof Construction 15' or less
to lowest member
Roof Construction 15' or more but
less than 20'
Roof Construction 15' or more but
less than 20'
6. Section 603.0 Types 1 and 2 Construction:
Rating
2 HRS
2 HRS
0 HRS
0 HRS
0 HRS
0 HRS
0 HRS
0 HRS
0 HRS
a. Section 603.1 General: Buildings and structures of
Types 1 and 2 construction are those in which the
walls, partitions, structure elements, floor, ceilings,
roofs and exits are constructed of approved
noncombustible materials. Each structure element shall
not be less than the required fireresistance rating
specified in Table 602, except as otherwise
specifically provided for a 780 CMR. Buildings of Types
1 and 2 construction shall be further classified as
Type 1A, 1B,2A, 2B, or 2C. Fireretardant-treated wood
shall only be used as specified in Table 602 and 780
CMR 2310.0
North Andover Pediatrics 800 Technology Street North Andover.
Code Analysis May 5, 2008 By RHC Professional Association
Analysis Based on Mass Sixth Edition State Building Code Page 3
7. Section 1008.0 Occupant Load
a. Design occupant load: In determining required
facilities, the number of occupants for whom exit
facilities shall be provided shall be established by
the largest number computed in accordance with 780 CMR
1008.1.1 through 1008.1.3.
b. Section 1008.1.1 Actual number: The actual number of
occupants for whom each occupied space, floor or
building is designed.
c. Section 1008.1.2: Number by Table 1008.1.2: The number
of occupants computed at the rate of one occupant per
unit of area as prescribed in Table 1008.1.2.
Table 1008.1.2 Occupancy Floor area in
sq.ft. per occupant
Business "B" 100 gross
d. Section 1008.1.3 Number by combination: The number of
occupants of any space as computed in 780 CMR 1008.1.1
or 1008.1.2 plus the number of occupants similarly
computed for all spaces that discharge through the
space in order to gain access to exit.
8. Section 1006.5 Length of Travel: All exits shall be so
located that the maximum length of exit accesss travel,
measured from the most remote point to an approved exit
along the natural and unobstructed line of travel, shall
not exceed the distances given in Table 10056.5
Table 1006.5 Length of Exit Access Travel
Use Group With Sprinkler System (Feet)
Business "B" 250 feet
9. Section 1009.0 Capacity of Egress Components:
a. Section 1009.2 Minimum width: The width of each means
of egress component shall not be less than the width
computed in accordance with Table 1009.2 for the
required capacity of the component, but not less than
the minimum width as prescribed by 780 CMR for each
such component.
a
' North Andover Pediatrics 800 Technology Street North Andover.
Code Analysis May 5, 2008 By RHC Professional Association
Analysis Based on Mass Sixth Edition State Building Code Page 4
b. Table 1009.2 Egress Width Per Occupant
Use Group With sprinkler system
(inches per person)
Stairways Doors Ramps &
Corridors
Business "B" 0.2 0.15
10. Section 1010.0 Number of Exits
a. Section 1010.2 Minimum number: Every floor area shall
be provided with the minimum number of approved
independent exits are required in Table 1010.2 based
on the occupant load, except as modified in 780 CMR
1010.3.
b. Table 1010.2 Minimum Number of Exits for Occupant Load
Occupant Load Minimum number of exits
500 or less 2
END OF CODE ANALYSIS
NORTH ANDOVER BUILDING DEPARTMENT
Tel: 978-688-9545
DEBRIS DISPOSAL FORM
In accordance with the provision of MGL c 40 S 54, a condition of Building Permit
at: 800 Turnpike St. -Unit 202 is that the debris resulting from this work shall be
disposed of in a properly licensed solid waste disposal facility as defined by MGL
C 11, S 150 A.
Also, note Permits are required under Fire Prevention laws Chapter 148 Section
10A.
The debris will be disposed of in:
Peabody, MA
(Location of Facility)
ture of Permit Applicant
5/14/08
The Commonwealth of Massachusetts
Department of Industrial Accidents
Office of Investigations
Ulf 600 Washington Street
Boston, MA 02111
www.mass.gov/dia
Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers
Applicant Information Please Print Legibly
Name (Business/Organization/Individual): PRISM BUILDERS, INC.
Address: 107 AUDUBON RD., BLDG. 1- SUITE 19
City/State/Zip: WAKEFIELD, MA 01880 Phone 9:
781/246-1900
Are you an employer? Check the appropriate box:
Type of project (required):
1. ❑ I am a employer with
4. I am a general contractor and I
6.WRemodeling
employees (full and/or part-time).*
have hired the sub -contractors
ew construction
2. ❑ I am a sole proprietor or partner-
listed on the attached sheet. t
7•
ship and have no employees
These sub -contractors have
8. ❑ Demolition
working for me in any capacity.
[No workers' comp. insurance
workers' comp. insurance.
5. ❑ We are a corporation and its
9. ❑ Building addition
required.]
officers have exercised their
10.F]Electrical repairs or additions
3. ❑ I am a homeowner doing all work
right of exemption per MGL
11.❑ Plumbing repairs or additions
myself. [No workers' comp.
c. 152, § 1(4), and we have no
12.❑ Roof repairs
insurance required.] t
employees. [No workers'
13.0 Other
comp. insurance required.]
Any applicant that checks box #1 must also fill out the section below showing their workers' compensation policy information.
t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such.
*Contractors that check this box must attached an additional sheet showing the name of the sub -contractors and their workers' comp. policy information.
lam an employer that is providing workers' compensation insurance for my employees. Below is the policy and jab site
information.
Insurance Company Name: AMERICAN INTERNATIONAL COMPANIES
Policy # or Self -ins. Lic. #: POL. //WC 6346633 Expiration Date:6/30b8
800 Turnpike Street—Unit 202
Job Site Address: City/State/Zip: North Andover, MA
Attach a copy of the workers' compensation policy declaration page (showing the policy number and expiration date).
Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a
fine up to $1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine
of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of
Investigations of the DIA for insurance coverage verification.
Ido hereby certify and Z he p d penalties ofperjury that the information provided above istrueand correct.
Snature: Date: l
Phone#: 781/2 6-1900
Official use only. Do not write in this area, to be completed by city or town official
City or Town: Permit/License #
Issuing Authority (circle one):
1. Board of Health 2. Building Department 3. City/Town Clerk 4. Electrical Inspector 5. Plumbing Inspector
6. Other
Contact Person:
A sm
Phone M
Board of Building Regulations and Standards s.
Construction Supervisor Licenser
License: CS 78126
Birthdate: 11311978
Expiration: 1/3/2009 Tr# 7969"
Restriction: 00
IV
I�
MATTHEW R GENZALE
19 GARDEN ST #307
DANVERS, MA 01923 Commissioner
TOWN OF NORTH ANDOVER
Building Inspection Department
Construction Control Affidavit
Project Title: North Andover Pediactrics - Tenant Fit -up
Project Location: 800 Turnpike Street, Suite 202, North Andover, Ma
Owner: KS Partnees, Suite 102, Billrica, MA
Description of Project: Tenant Fit -up for North Andover Pediactrics
In accordance with Section 116.0 of the Massachusetts State Building Code, I, Richard H Casale AIA, Massachusetts
Registration No: 2020, being a Registered Professional Architect, hereby certify that I have reviewed all design plans and
specification concerning:
Entire Project Architectural X Structural F] Mechanical
Other (specify)
For the above named project and that, to the best of my knowledge, such plans and specifications meet the applicable
provisions of 780CMR, the Massachusetts State Building Code, and all accepted architectural /engineering practices.
I further certify that I shall perform the necessary professional services and be present on the construction site on periodic
basis to determine that the work is proceeding in accordance with the documents approved for the building permit and
shall be responsible for the following as specified in Section 116.2.:
1. Review, for conformance to the design concept, shop drawings, samples and other submittals
which are submitted by the contractor in accordance with the requirements of the construction
documents.
2. Review and approval of the quality control procedures for all code -required controlled materials.
3. Be present at intervals appropriate to the stage of construction to become, generally famili,, with
the progress and quality of the work and to determine, in general, if the work is being performed in
a manner consistent with the construction documents.
Pursuant to Section 116.4, 1 shall keep appropriate records. Upon completion of the work I shall submit the Construction
Control Certification of Completion indicating that the work has been performed in accordance with the approved plans and
780 CMR.
Signature:
\C QED AR ti
H. cgs F�
No. 2020
01
C' BOSTON
MA.
Seal: OF
Date: d��0 ez S
Projectfe.
Project Location:
TOWN OF NORTH ANDOVER
Building Inspection Department
Construction Control Affidavit
'IN -800 Turnpike Street, Suite 202, North Andover, Ma
Owner: KS Partnees Suite 102 Billrica MA
Description of Projec6 Tenant Fit -up for North Andover Pediactrics
In accordance with Section-TP6.0 of the Massachusetts State Building Geode, I, Rich'a`rd, Fi Casale AIA, Massachusetts
Registration No: 2020, being a Registered Professional Architect, hereby certify-thlfi-f`ha reviewed all design - A
specification concerning:
Entire Project F� Architectural a Structural F] Mechanical
Other (specify)
For the above named project and tfiat, to the best of my knowledge, such plans and specifidations meet the applicable
provisions of-780CMR, the Massachusetts State Building Code, and all accepted architectural /engineering practices.
f
I further certify that -1 shall perform the necessary professional services ,and be present on the construction site on periodic
basis to determine that the work is proceeding in accordance ocumen s -approved for the building permit and
shall be responsible for the fallowing as specified in Section 116. .: Tf
1. Review, for conformance to the design concept, shop drawings, samples and other submittals
which are submitted by lie contractor in accordance with the requirements of the construction
documents.
2. Review and approval of the quality control procedu�s for all code -required controlled materials.
3. Be prgs�ea at-interVE appropriate to the stage of construction to become, generally familiar with
the progress -9nd quality of the work and to determine, in general, if the work is being performed in
a manner consistent with the constructiogdocuments.
Pursuant to Semon 116.4, 1 shall keep appropriate records. Upon edmpletion of the wwk-- hall submit the Construction
Control Certification o! -Completion indicating that the work ha47been performed in accordance with the approved plans and
780 CMR.