Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Building Permit #1000-2016 - 874 SALEM STREET 3/24/2016
BUILDING PERMIT OF ttORTH q 1 ` TOWN OF NORTH ANDOVER APPLICATION FOR PLAN EXAMINATION f T Z y T n _ Permit No#: � Date Received A°'rare°Fea q5 �SSAcmus�� Date Issued: IMPORTANT:Applicant must complete all items on this page LOCATION 3?y c5ct� Sf. Print PROPERTY OWNER 7-o6\. Con1o�5 Print 100 Year Structure yes nn MAP (o .0 PARCEL:� 1 ZONING DISTRICT: Historic District yeso Machine Shop Village yes no TYPE OF IMPROVEMENT PROPOSED USE Resid ntial Non- Residential ❑ New Building R16ne family ❑Addition ❑Two or more family ❑ Industrial &41teration No. of units: ❑ Commercial ❑ Repair, replacement ❑Assessory Bldg ❑ Others: ❑ Demolition ❑ Other ❑,Flootl lain' ®Wetlantls, ❑Sepfic ❑Welh p �11Vaterstedl!®istnct a w? 0(1Nater/Sewers DESCRIPTION OF W//��ORK TO BE PERFORMED: n yV 5014-- eAZG r;C� +`G1S on rco� of ex,-s" 6b , fw' nn P�� w Ho►w 's c6in c,-,I wm . 2(a Orve,1 s oaf cd. & (e.(Q 3 K� . i Identification- Please Type or Print Clearly OWNER: Name: 'Sok. Phone: (o1?- (o9q- X9) Address: 8?y 3t- Contractor Name: T)ao;&1 D. 1 o z; Phone: Email: +-VIC4 SP so 6'r .cow% Address: S��K..Ua, ,�►, +oh Nt A oink-7 } � R�,Q_ w.l � . Supervisor's Construction License: (o l -7 Exp. Date: 91 I311(o Home Improvement License: I S 72- Exp. Date: 3 Fs ► 7 ARCHITECT/ENGINEER Phone: ��S' 7�S-a'�fs`l erc4.5TSa Address: 3oS5 Clcarv-40 W(,l .Sew. Mcd,LA flyroa Reg. No. s7;z I U_0 FEE SCHEDULE:BULDING PERMIT:$12.00 PER$1000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PER S.F. Total Project Cost: $ 17-c*o FEE: $ _aoli Check No.: -I (p°I Receipt No.: NOTE: Persons contracti - registered contractors do not have access,t �ranty fund N � ;- _- - Building Department The following is a list of the required forms to be filled out for the appropriate permit to be obtained. Roofing, Siding, Interior Rehabilitation Permits Building Permit Application Workers Comp Affidavit Photo Copy Of H.I.C. And/Or C.S.L. Licenses Copy of Contract Floor Plan Or Proposed Interior Work Engineering Affidavits for Engineered products OTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit Addition Or Decks Building Permit Application Certified Surveyed Plot Plan Workers Comp Affidavit Photo Copy of H.I.C. And C.S.L. Licenses Copy Of Contract Floor/Cross Section/Elevation Plan Of Proposed Work With Sprinkler Plan And Hydraulic Calculations (If Applicable) Mass check Energy Compliance Report (If Applicable) Engineering Affidavits for Engineered products OTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit New Construction (Single and Two Family) Building Permit Application Certified Proposed Plot Plan Photo of H.I.C. And C.S.L. Licenses Workers Comp Affidavit Two Sets of Building Plans (One To Be Returned) to Include Sprinkler Plan And Hydraulic Calculations (If Applicable) Copy of Contract 2012 IECC Energy code Engineering Affidavits for Engineered products OTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg. Permit In all cases if a variance or special permit was required the Town Clerks office must stamp the decision from the Board of Appeals e this recorded at the Re istr of Deeds. One co and roof of recording The applicant must then t Y P that the appeal period is over. Th pp g g Y P must be submitted with the building application Doe:Building Permit Revised 2014 Plans Submitted Plans Waived ❑ Certified Plot Plan ❑ Stamped Plans ❑ TYPE OF SEWERAGE DISPOSAL Public Sewer ❑ Tanning/MassageBody Art ❑ Swimming Pools ❑ well ❑ Tobacco Sales ❑ Food Packaging/Sales ❑ Private(septic tank,etc. ❑ Permanent Dumpster on Site ❑ THE FOLLOWING SECTIONS FOR OFFICE USE ONLY INTERDEPARTMENTAL SIGN OFF - U FORM PLANNING & DEVELOPMENT Reviewed On Signature_ COMMENTS CONSERVATION Reviewed on Signature COMMENTS WEALTH Reviewed on Signature COMMENTS Zoning Board of Appeals:Variance, Petition No: Zoning Decision/receipt submitted yes Planning Board Decision: Comments Conservation Decision: Comments a Water& Sewer Connection/Signature& Date Driveway Permit DPW Town Engineer: Signature: Located 384 Osgood Street FIRE�DEPAR+TMENT ' Temp'Dum ster, ontsite ,a nog L�oc=:da124 Mam„Sta � �,t a � � l, + t �k}`` MA, e . t �iCy' yC�Car69 "i...�$.'._.... .t.u. `"' +,€�y :jt�'�.�� �#" } r �+.�•� sxr+s� `��L r�,��F.«,i 3�. ��i'*t•i�`�'9 'gyp` stw;;�y." 'c.r 't."-"`�"f`T�"'y"';.o.��.w "; � 4T, t...J��$ti 1. i t-Q� ii y r !-'++4' R�+ c�� z 14 r1 2 t r spa .a s Ca '' •a 1 t a T. {� a e COMMENTS '/�3� t = x � 71. Dimension Number of Stories: Total square feet of floor area, based on Exterior dimensions. Total land area, sq. ft.: I ELECTRICAL: Movement of Meter location, mast or service drop requires approval of Electrical Inspector Yes No DANGER ZONE LITERATURE: Yes No MGL Chapter 166 Section 21A—F and G min.$100-$1000 fine NOTES and DATA-- (For department use) i ® Notified for pickup Call Email Date Time Contact Name Doc.Building Pennit Revised 2014 Location i � � - �UfX� - Zit No. � Date .w- TOWN OF NORTH ANDOVER Certificate of Occupancy $ Building/Frame Permit Fee $�C Foundation Permit Fee $ Other Permit Fee $ `. TOTAL Check r 3 5 Building Inspector r 1 NORT#i - . _ _ . w. .. . . c . . ve: 490 0 No. zol h ver, Mass, Olktotl �r oLA142 4 �oCHIC149WICK 1 �.9 q04 Teff s � BOARD OF HEALTH Food/Kitchen PERMIT LD Septic System THIS CERTIFIES THAT BUILDING INSPECTOR ...................... .01►+!�................ �s ......... ....... ........... has permission to erect .......................... building's on ..... � .., �...• r!!�... � .........,.,., Foundation �� Rough to be occupied as ..�..... ... .... � ................... `............�w.......................... Chimney provided that the person accepting this permit shall in every respect conform to the terms of the application Final on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection,Alteration and Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR VIOLATION of the Zoning or Building Regulations Voids this Permit. Rough Final PERM]T EXPIRES IN 6 MONTHS ELECTRICAL INSPECTOR UNLESS CONSTRUCTIO TARTS Rough Service .............. ... .. .. ... ... ..'"..'"........................... Final BUILDING INSPECTOR GAS INSPECTOR Occupancy Permit Required to Occupy Buildinz Rough Display in a Conspicuous Place on the Premises — Do Not Remove Final No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. Burner Street No. Smoke Det. Version#55.3-�- TBD ° PIL "•! r March 23,2016 ? G n A8 LARDO E. RE: CERTIFICATION LETTER `l DE VERA.v STRUCTURAL y too. 52160 Project/Job# 0183598 , e Project Address: Conides Residence9�� 874 Salem St �SS�cNALtia° North Andover, MA 01845 Digitally signed by Abe De Vera AH] North Andover Date:2016.03.2314:15:33-07'00' SC Office Wilmington Design Criteria: -Applicable Codes= MA Res. Code, 8th Edition,ASCE 7-05, and 2005 NDS - Risk Category = II -Wind Speed = 100 mph, Exposure Category C -Ground Snow Load = 50 psf - MPI: Roof DL= 10.5 psf, Roof LL/SL= 34.5 psf(Non-PV Areas), Roof LL/SL= 18.5 psf(PV Areas) - MP2: Roof DL= 10 psf, Roof LL/SL= 35 psf(Non-PV Areas), Roof LL/SL= 22 psf(PV Areas) Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.33365 < 0.4g and Seismic Design Category(SDC) = C < D To Whom It May Concern, A jobsite survey of the existing framing system of the address indicated above was performed by a site survey team from SolarCity. Structural evaluation was based on site observations and the design criteria listed above. Based on this evaluation, I certify that the existing structure directly supporting the PV system is adequate to withstand all loading indicated in the design criteria above based on the requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally, I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes for loading. The PV assembly hardware specifications are contained in the plans/docs submitted for approval. S-incerely, Abe De Vera,P.E. Professional Engineer Main: 888.765.2489,x.57526 email; adevei-d@soiattity.com 3055 Cfearview VMy San Mateo,CA 94402 -.(650)638-1028 (888)SOL-CITY -(650)638-1029 sclardiity.corn NC',090I147T,�172' PA b>.Of'—A €„s wat. It b. .3r.,ti,FSr rc. „tSvw-0. ,t'F a_n.,..-,:e G .. ...1': � Version#55.3-TBD PIL 0 a r 0,ty. HARDWARE DESIGN AND STRUCTURAL ANALYSIS RESULTS SUMMARY TABLES Landscape Hardware-Landscape Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MPI 64" 24" 39" NA Staggered 63.0% MP2 64" 24" 39" NA Staggered 55.7% Portrait Hardware-Portrait Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MP1 48" 19" 65" NA Staggered 78.6% MP2 48" 18" 65" NA Staggered 69.4% Structure Mounting Plane Framing_ Qualification Results Type Spacing Pitch Member Evaluation Results MPI Stick Frame @ 16 in.O.C. 380 Member Impact Check OK MP2 Stick Frame @ 16 in.O.C. 320 Member Impact Check OK Refer to the submitted drawings for details of information collected during a site survey. All member analysis and/or evaluation is based on framing information gathered on site.The existing gravity and lateral load carrying members were evaluated in accordance with the IBC and the IEBC. 3055 Clearvlew=My San Mateo,CA 94402 -(650)638-1028 (688)Sol-CITY P(65Vj 638-'1029 sclarcit°y.ccm 4�00IF,I P37,All 243171.A,r�24.e, , f:._aW ',cf) Dc sa5f:'VC:�^.' ..,.�Sz:.:.'•.ta.2..fi a�,1,;.;� �„S�.�i i. :k.2:;.H:»T.4.�:,.:YS Cv,`,,,. S;:.i ig£:72. tt €R a6 It.. Kroi!:'Naa.. ?:.#��d ti'_4rC .,2.�-,N4'i C9i.,,.r,tilaL... ,5 tP:, »...,.o,WA 3., i:: tCH OX CAV A4., s tI W t`0,4g fi §.,V,'AYd;+ ,a_'E;C..i,,`!D P,SC,�.,'.n. '.'J' :6.1,4.'a.2,g4 , t.z 24. ,i4C .,c7tfRz a::,�e - re naA ?t, es.x .¢'S4, ';.t EA.,a�".4 tq�{-a.w.,•'.s+k .:f[,-'�.s:(c�z �„�.(..Y.+_.c'9'6,EM:ad.-?c=.�Y 1:,k Y�e..d ..ic ;'N YCf 'Snr.E�4g N... :2ot...F.,,-.u..,..'.» x.4�.,> i! A✓rs. _i k.,^,?r„<.tN :x q"� ::'i°i..:3..n.Y. .u.:+:S.:. .r. .'.n !rt4r OKWa ,.'?C,,,--.or22d..,' STRUCTURE ANALYSIS LOADING SUMMARY AND MEMBER CHECK - MPL Member Properties Summary MP1 Horizontal Member Spans Rafter Pro erties Overhang 1.16 ft Actual W 1.50" Roof System Pro erties San 1 13.79 ftActual D 7.25" Number of Spans(w/o Overhang) 1 San 2 Nominal Yes Roofing Material Comp Roof San 3 A 10.88 in.^2 Re-Roof No San 4 S. 13.14 in.^3 Plywood Sheathing Yes Span 5 11 47.63 in.^4 Board Sheathing None Total Rake Span 18.97 ft TL DefTn Limit 120 Vaulted Ceiling No PV 1 Start 0.83 ft Wood Species SPF Ceiling Finish 1/2"Gypsum Board PV 1 End 13.58 ft Wood Grade #2 Rafter Slope 380 PV 2 Start Fb 875 psi Rafter Spacing 16"O.C. PV 2 End F. 1 135 psi Top Lat Bracing Full PV 3 Start j E 1 1400000 psi Bot Lat Bracing At Supports PV 3 End Em;,, 510000 psi Member Loading mary Roof Pitch 10/12 Initial Pitch Ad'ust Non-PV Areas PV Areas Roof Dead Load DL 10.5 psf x 1.27 13.3 psf 13.3 psf PV Dead Load PV-DL `3.0 psf x 1.27 3.8 psf Roof Live Load RLL 20.0 psf x 0.73 14.5 psf Live/Show Load LL/SL 1,2 50.0 psf x 0.69 1 x 0.37 34.5 psf 18.5 psf Total Load(Governing LC TL 1 47,8 Psf 35.6 Psf Notes: 1. ps=Cs*pf; Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf=0.7(Ce)(Ct)(IS)pg; Ce=0.9,Ct=1.1, I5=1.0 Member Desi n Summa (per NDS Governing Load Comb CD CL + GL - CF Cr D+S_ 1.15 1.00 1 0.35 1 1.2 1.15 Member Anal sis Results Summary Governing Analysis I Pre-PV Demand-1 1Post-PV Demand NetImpact I Result Gravity Loading Check 1 1370 psi 1020 psi 0.74 Pass ;CALCULATION OF DESIGN WIND LOADS.-MPi Mounting Plane Information Roofing Material Comp Roof PV System Type _ SolarCity SleekMountTm Spanning Vents No Standoff Attachment Hardware Comp Mount. it Roof Slope380 Rafter Spacing _ 16"0 C. , Framing Type Direction Y-Y Rafters Purlin.Spacing _ _._ . X-X Purlins Only...a NA Tile Reveal Tile Roofs Only NA _...._ _._ _._ ._. . ...__. ... „-..... Tile Attachment System Tile Roofs Only NA Isiandirig seamiTrap spacing SM Seam Only NA Wind Design Criteria Wind Design Code 4 _ ASCE 7-05__ Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 100 mph Fig. 6-1_ Exposure Category C _ Section_6.5.6.3 Roof Style_ Gable Roof Fig.6_116/C/D-14A/B Mean Roof Height h 25 ft Section 6.2 Wind Pressure Calculation Coefficients _ Wind Pressure Exposure KZ 0.95 Table 6-3 Topographic Factor Krt _... . _ _ 1.00 Section 6.5.7 Wind Directionality Factor Kd � 0.85 Table 6-4 Im ortance Factor I 1.0 Table 6-1 Velocity Pressure qh qh = 0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 20.6 psf Wind-Pressure Ext. Pressure Coefficient U GC u -0.95 Fig.6-11B/C/D-14A/B Ext.Pressure Coefficient Down GC wn 0.88 Fig.6-116/C/D-14A/B Design Wind Pressure p p =qh (GC ) Equation 6-22 Wind Pressure Up Nual -19.6 psf Wind Pressure Down 18.0 psf 'ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing _ Landscape 64" _ _ 39" Max Allowable Cantilever Landscape _... _ -24° NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area _ _ Trib.__ 17 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff _ T-actual _ � -315 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand Ca aci DCR 63.0% X-Direction Y-Direction Max Allowable Standoff Spaces _ Portrait 48" 65" -_ __ _ Max Allowable Cantilever Portrait 19" NA Standoff Configuration Portrait Staggered Max Standoff TributaryArea Trib _ 22_sf PV Assembly Dead.Load - - --_ .. .W PV _ _ _ ,3.0 psf _ . Net Wind Uplift at Standoff._ _ T-actual'. _ .. .� ��_ -3931bs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand Ca ci ---ECR 78.6% STRUCTURE ANALYSIS'- LOADING_SUMMARY AND MEMBER CHECK- MP2 Member Properties Summary Horizontal Member S ans Rafter Pro erties MP2 Overhang 1.16 ft Actual W 1.50" Roof System Pro erties San 1 9.75 ft I Actual D 5.50" Number of Spans(w/o Overhang) 1 San 2 Nominal Yes Roofing Material _, Comp Roof San 3, A. 8.25 in.A2 Re-Roof No San 4 SX 7.56 in.A3 Plywood Sheathing Yes Sans f 20.80 in.^4 Board Sheathing None Total Rake Span 12.86 ft TL DefPn Limit 120 Vaulted Ceiling No PV 1 Start 1.08 ft Wood Species SPF Ceiling Finish 1/2"Gypsum Board PV 1 End 9.42 ft Wood Grade #2 Rafter Sloe 320 PV 2 Start Fb_ 875 psi Rafter Spacing 16"O.C. PV 2 End F„ 135 psi Top Lat Bracing Full PV 3 Start E 1400000 psi Bot Lat Bracing At Supports PV 3 End Emin 510000 psi Member Loadingmary Roof Pitch 8112 Initial Pitch Ad'ust Non-PV Areas PV Areas Roof Dead Load DL 10.0 psf x 1.18 11.8 psf 11.8 psf PV Dead Load PV-DL 3.0 psf x 1.18 3.5 psf Roof Live Load RLL 20.0 psf x 0.83 16.5 psf Live/Snow Load LL SL1,2 50.0 psf x 0,7 1 x 0.44 35.0 psf 22.0 psf Total Load(Governing LC I TL 1 46.8 Psf 37.3 psf Notes: 1. ps=Cs*pf;Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf=0.7(Ce)(CO(Is)pg; Ce=0.9,Ct=1.1,I5=1.0 Member Design Summa er NDS Governing Load Comb CD GL + CL CF Cr D+S 1.15 1.00 1 0.62 1 .1.3 1.15 Member Anal sis Results Summary Governing Analysis Pre-PV Demand I Post-PV Demand Net Impact Result GravityLoadingCheck 1150 psi 917 psi 0.80 Pass ,CALCULATION OF DESIGN WAND LOADS MP2 Mounting Plane Information Roofing Material Comp Roof PV System Type _ SolarCity SleekMount'"' _ . Spanning Vents _ No�_ Standoff Attachment Hardware, Com Mount Type C Roof Slope 320 Rafter Spacing Framing T e Direction Y-Y Rafters Purlin Spacing —,X,-X,Purlins,Only _.-_ __ NA Tile Reveal Tile Roofs Only NA m Tile Attachment System Tile Roofs Only NA ._ _ Standin Seam/Trap Spacing SM Seam Only NA Wind Design Criteria Wind Design Code _ ASCE 7-05 Wind-be—sign, eth_Mod �,�T _— Partially/Fully Enclosed Method, _ Basic Wind Speed V 100 mph Fig. 6-1 Exposure CategoryC Section 6.5.6.3 Roof Style Gable Roof Fig.6-11B/C/D-14A/B ........�._.. _.. .__ ., _.. Mean Roof Height h 15 ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 Table 6-3 _. a ... _. Topographic Factor K 100 _ Section 6.53 Wind Directionality Factor Kd 0.85 Table 6-4 Im ortance Factor I 1.0 Table 6-1 Velocity Pressure qh qh = 0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 18.5 Psf Wind Pressure Ext. Pressure Coefficient U GC -0.95 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient Down GCp mown) 0.88 Fig.6-118/C/D-14A/B Design Wind Pressure p p= qh(GC) Equation 6-22 Wind Pressure Up Pfuu) -17.6 psf Wind Pressure Down 16.2 psf ALLOWABLE STANDOFF SPACINGS X-Direction,- Y-Direction Max Allowable Standoff Spacing _LL Landscape _ „y W _._._...._EN_ 64 F. _. _39 — -- -nd - Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trio 17 sf _ PV Assembly Dead Load W-PV3.0 psf Net Wind Uplift at Standoff T-actual Uplift Capacity-of_Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 55.7% y ' X:Direction Y-Direction Max Allowable Standoff Spacing Portrait 48" 65" Max Allowable Cantilever_ _ Portrait . _ NA _ Standoff Configuration Portrait Staggered Max Standoff Tributary Area__ Trio _' _,... _ 22,sf, PVAssembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff._ _T„actual .. . _..: _ _ -347 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand Ca acit DCR 69.4% DocuSign Envelope ID:C8ED1554-E519-45D1-B5D1-1E1AEDE86FC2 SolarGty SolarLease ,' Customer Name and Address Installation Location Date John Conides 874 Salem St 3/18/2016 874 Salem St North Andover,MA 01845 North Andover,MA 01845 Here are the key terms of your SolarLease Agreement >a. Co).V `. ,Amount due at contract signing First year mon qoyment Agrees eBsm (Est.Price per kWh F rst ji�a .$4.1504) �� Initial here_ ,J Initial here Q The SolarCity Promise DS •We provide a money-back energy performance guarantee. JU •We guarantee that if you sell your Home,the buyer will qualify-to assume your Agreement. ... ............................................Initial here •We warrant all of our roofing work. Ds •We restore your roof at the end of the Agreement: J •We warrant,insure and repair,the System. ..` ... ... " ......... ..................................................... ........................ ........................ .........Initial her •We fix or pay for any damage we may cause to,your property. •We provide 24/7 web-enabled monitoring at no additional cost. •The rate you pay us will remain fixed for'the term of the Agreement. •The pricing in this Agreement is valid,for 30 days after 3/18/2016. ti C� Your SolarCity lease Agreement Details Your Choices at the End of the Initial Your Prepayment Choices During Amount due at contract signing Term: the Term: $0 •SolarCity will remove the System,at no If you move,you may prepay the Est.amount due at installation additional cost to you. remaining payments(if any)at a $0 •You can upgrade to a new System"withdiscount. the latest solar technology under a new Est.amount due at building inspection contract. $0 __ __ •You may renew your Agreement for up to Est.first year production ten(10)years in two(2)five(5)year 7,759 kWh increments. '*Otherwise,the,Agreement will automatically renew for an additional one ,(1)year term at 10%less than the then current average rate charges by your local utility. Y 3055 Clearview Way,San Mateo CA 944021 888.765.2489 solarcity.corn 1672502 t SolarLease Agreement,version 7.1.3,February 15,2016'x, SAPC/SEFA Compliant Contractor License MA HIC 168572/EL 1136MR r Document generated on 3/18/2016 -- r copyright 2008-2015 Sola rCityCorporation,All Rights Reserved �■ DocuSign Envelope ID:C8ED1554-E519-45D1-B5D1-1E1AEDE86FC2 1. INTRODUCTION 3. SYSTEM DESCRIPTION This Solarl-ease(this"Lease"or"Agreement")is.the Lease and installation of a 7.8 kW DC photovoltaic agreement between you and SolarCity Corporation system consisting of PV modules,corresponding. (together with its successors and assigns,"SolarCity"or inverter(s)and a mounting system designed for "we"),covering the lease to you of the solar panel installation and operation at your Home. system(the"System")described.below.The System will REST OF PAGE INTENTIONALLY LEFT BLANK. be installed by SolarCity at the address you listed above.This Lease will refer to this address as the "Property"or your"Home."This Lease is up to thirteen (13) pages long and has up to three(3) Exhibits depending on the state where you live.This Lease has disclosures required by the Federal Consumer Leasing Act and,where applicable,state law.SolarCity provides you with a Performance Guarantee and Limited Warranty (the"Limited Warranty").The Limited Warranty is attached as Exhibit 2.SolarCity will also provide you with a System user manual entitled"Solar Operation and Maintenance Guide"(the"Guide"),that contains J. important operation,maintenance and service information.This is a legally binding agreement,so please read everything carefully including all of the exhibits. If you do not meet your contract obligations under this Lease,you may lose your rights to the System: If you have any questions regarding this Lease,please ask , your SolarCity sales consultant. THIS AGREEMENT SUPERSEDES ALL PRIOR EXISTING CONTRACTS BETWEEN YOU AND SOLARCITY THAT PERTAIN TO THE"SYSTEM" DEFINED IN THIS s ,AGREEMENT. 2. LEASE TERM SolarCity agrees to lease you the System for 20 years (240 full calendar months),plus,if the Interconnection Date is not on the first day of a calendar month,the number of days left in that partial calendar month, - including the Interconnection Date.We refer to this period of time as the"Lease Term."The Lease Term begins on the Interconnection Date.The Interconnection Date is the ^ date that the System is turned on and generating power. . SolarCity will notify you by email when your System is ready to be turned on. i' solaftease Agreement,version 7:1.3,February 15,2016 ; 1672502 ❑■ DocuSign Envelope ID:.C8ED1554-E519-45D1-B5D1-1E1A.EDE86FC2 4. LEASE PAYMENTS;AMOUNTS ... ....... .. . A. Amounts Due at Lease Signing,Installation and Building B. Monthly Payments: j I Inspection: - i I j Your first monthly paymentis$97.25, Payments Due at Signing: followed by 11 monthly payments of$97.25 each; j Amount Due at Lease Signing: $0.00 followed by 12 monthly payments of$97.25 each, Delivery/Installation Fee: 0.00 followed by 12 monthly payments of$97.25 each, Total Due at Lease Signing $0.00 followed by 12 monthly payments of$97.25 each, followed by 12 monthly payments of$97.25 each, Payments Due at Installation: followed by 12 monthly payments of$97.25 each, 50%of,Lease Prepayment: $0.00 followed by 12 monthly payments of$97.25 each, Estimated Tax*: 0.00* followed by 12 monthly payments of$97.25 each, Payments Due after Building Inspection: $0.00 followed by 12 monthly payments of$97.25 each, followed by 12 monthly payments of$97.25 each, Payments Due after Building Inspection: followed by 12 monthly payments of$97.25 each, 50%of Lease Prepayment: $0.00 followed by 12 monthly payments of$97.25 each, Estimated Tax*: 0.00* followed by 12 monthly payments of$97.25 each, Total Due after Building Inspection: followed by 12 monthly payments of$97.25 each, j $0,00 followed by 12 monthly payments of$97.25 each, I followed by 12 monthly payments of$97.25.each, followed by 12 monthly payments of$97.25 each, followed by 12 monthly payments of$97.25 each, followed by 12 monthly payments of$97.25 each, i followed by 12 monthly payments of$97.25 each. Your total lease payments,excluding tax,are$23,340.00.Your estimated average monthly tax payments are$0.00: Your first Monthly Payment is due on the first day of the first full calendar month following the Interconnection Date. After c" your first Monthly Payment,future Monthly Payments(and any applicable taxes)are due on the first day of the calendar month:, i j i C. Other Charges: D. Total of Payments(A+B+C)_$23,340.00 i This is the total amount you will have paid by the endof this I If you make your Monthly Payments by allowing us to Lease by making 240 payments in total. It includesahe I automatically debit your checking or savings account,then Monthly Payments stated above and estimated taxes of$0. you will receive a discount of$7.50 on'your Monthly Payments.The Monthly Payments listed above reflect this discount. If you do not allow the automatic debit,this discount will not be applied to your Monthly Payments and A I each Monthly Payment will be$7.50 greater. Solarlease Agreement,version 7,1.3,.February 15,2016 1672502 _ ,,\ ;. e ,' DocuSign Envelope ID:C8ED1554-E519-4501-B5D1-lE1AEDE86FC2 E. Purchase Option At End of Lease Term: F. Other Important Terms: F You do not have an option to purchase the System at the end See Section 2 above for additional information on the Lease of the Lease Term. Term and also see below for additional information on termination, purchase options,renewal options,maintenance responsibilities,warranties,late and default charges and prohibition on assignment without SolarCity's consent. Payments due upon installation are due immediately prior to commencement of installation. 5. LEASE OBLIGATIONS (x) notify SolarCity if you think the System is (a) System,Home and Property Maintenance damaged or appears unsafe;if the System is stolen;and prior to changing your power You agree to: supplier; � a (i) only have the System repaired pursuant to (xi) have anyone who has an ownership interest the Limited Warranty and reasonably in your Home sign this Lease; 4 cooperate when repairs are,being made;' (xii) return any documents we send you for (ii) keep trees,bushes and hedges trimmed so signature(like incentive claim forms)within that the System receives as muchsunlight as seven(7)days of receiving them;and it did when SolarCity installed it; (xiii) maintain and make available,at your cost,a (iii) keep the panels clean,pursuant to the functioning indoor internet connection with a Limited Warranty and the Guide; router,one DHCP enabled Ethernet port with (iv) not modify your Home in a way that shades internet,access and standard AC power outlet the System; close enough and free of interference to enable an internet-connected gateway (v) be responsible"for any conditions at your provided by SolarCity to communicate Home that affect the installation(e.g. wirelessly with the system's inverter(typically blocking access to the roof or removing a tree this is 80 feet,but may depend on site that is in the way,prior work you have done conditions).See Section 2(c)(ii)of the Limited on your home that was not permitted); Warranty for details;and (vi) not remove any markings or identification (xiv) if your home is governed by a home owner's tags on the System; association or similar community organization, (vii) permit SolarCity,after we give you obtain all approvals and authorizations for the. reasonable notice,to inspect the System for System required by that organization and proper operation as we reasonably determine advise us of any requirements of that necessary; organization that will otherwise impact the System,its installation or operation. (viii) use the System primarily for personal,family or household purposes;but not to heat a (b) System Construction,Repair,Insurance and . swimming pool; SolarCity's obligations: (ix) not do anything,permit or allow to exist any,' SolarCity agrees to: condition or circumstance that:would cause the System not to operate a 11 s intended at the (i) schedule the-installation of the System at a Property mutually:convenient date and time; (ii) construct the System according to writter� plans you review; A R1 SolarLease Agreement,version 7.1..3,February 1S,2016 r1672S02 �• DocuSign Envelope ID:C8ED1554-E519-45D1-B5D1-1E1AEDE86FC2` (iii) provide you with a web-enabled meter to or withdrawal right,that is returned or accurately measure the amount of power the refused by your bank;and System delivers to you, (iv) notify`you if the System design has to be (iii) Late payments:accrue interest at twelve percent(12%)annually,or the maximum materially changed so that you can review allowable by applicable law. any such changes; (y) clean up after ourselves during the (e) insurance construction of the System; SolarCity shall insure the System against all damage or (vi) repair the System pursuant to the Limited loss unless(i)athat damage or loss is caused by your Warranty and reasonably cooperate with you gross negligence;or(ii)that damage or loss is caused when scheduling repairs; by ball,strikes;or,(iii)you intentionally damage the (vii) create a priority stream of operation and System, maintenance payments to provide enough (f) Estimated Taxes cash flow in our financing transactions to pay You agree to pay any applicable sales or use taxes on for the Limited Warranty obligations and the the Monthly Payments due under this Lease. If this repair and maintenance of the System in Lease contains a purchase option at the end of the accordance with this Lease even if SolarCity Lease Term,you agree to pay any applicable`tax on the ceases to operate;and purchase price for the System.You also agree to pay (viii) not put a lien on your.Home or Property: as invoiced any applicable personal,property taxes on the System that your local jurisdiction may levy.The (c) Home Renovations or Repairs total estimated amount you will pay for taxes over the If you want to make any repairs or improvements to / Lease Term is$0. the Property that could interfere with the System (g) No Alterations (such as repairing the roof where the System is You agree that you will not snake any modifications, located),yo'u may only remove and replace the System improvements,revisions or additions to the System or -pursuant to the Limited Warranty. - take any other action that could void the Limited (d) Automatic Payment Fees;Late Charges Warranty on the System without SolarCity's prior In addition to the other amounts you agree to pay in written consent. f you make any modifications, this Lease,you agree to pay the following: improvements,revisions or additions to the System, they will become part of the System and shall be (i) Automatic Payment Discount: If you make , SoWcity's_property. your Monthly Payments by allowing us to automatically debit your checking or (h) Access to the System savings account,then you will receive a (i) You grant to SolarCity and its employees, discount of$7.50 on your Monthly ,- agents and contractors the right to Payments.The Monthly Payments listed in reasonably access all of the Property as Section 4 of this Agreement reflect this necessary for the purposes of(A)installing, discount. If you do not allow the automatic constructing,operating,owning, repairing, debit,this discount will not be applied to removing and replacing the System or making your Monthly Payments and.each Monthly any additions to the System-or installing Payment will be$7.50 greater;\ complementary technologies on or about the location of the System,(B)enforcing (ii) Returned Check Fee:$25(or such dower SolarCity's rights as to this Lease and the amount as required by`law)-for any check System;(C)installing, using and'maintaining n 0�� So4l_ease Agreement,version 7:1.3,Febr6ary 15,2016 1672502 ❑ F fi DocuSign Envelope ID:C8ED1554-E51945D1-B5D1-1E1AEDE86FC2`• electric lines,inverters and meters;necessary ALL CIRCUMSTANCES AND SHALL NOT BE SUBJECT TO to interconnect the System to your electric. ANY ABATEMENT,DEFENSE,COUNTERCLAIM,SETOFF, system at the Property and/or to the utility's RECOUPMENT OR REDUCTION FOR ANY REASON electric distribution system;or(D)"taking any WHATSOEVER, IT BEING THE EXPRESS INTENT OF THE other action reasonably necessary in PARTIES THAT ALL=AMOUNTS PAYABLE BY YOU connection with the`construction,, HEREUNDER SHALL BE AND CONTINUE TO BE PAYABLE installation,operation,maintenance,removal ,IN'ALL EVENTS INCLUDING BY YOUR HEIRS AND or repair of the System.This access right shall ESTATE AND, EXCEPT AS SET FORTH BELOW IN continue for up to ninety(90)days after this SECTIONS 6,23 AND 24,YOU HEREBY WAIVE ALL Lease expires to provide SolarCity with time RIGHTS YOU MAY HAVE TO REJECT OR CANCEL THIS to remove the System at the end of the Lease LEASE,TO REVOKE ACCEPTANCE OF THE SYSTEM,OR Term.SolarCity shall provide you with TO GRANT ASECURITY INTEREST IN THE SYSTEM. reasonable notice of its need to access the (k) You authorize SolarCity,or its designee,to obtain your Property whenever commercially reasonable. credit report now and in the future,check your credit (ii) During the time that SolarCity has access and employment history,answer questions others rights you shall ensure that its access rights may ask regarding your credit and share your credit are preserved and shall not interfere with or information with SolarCity's financing partners.You permit any third party to interfere with such certify that all information you provide to us in rights or access. You agree that the System is connection with checking your credit will be true and not a fixture, but SolarCity-has the right to file understand that this information must be updated any UCC-1 financing°statement or fixture upon request if your financial condition changes. filing that confirms its interest in the System. 6. CONDITIONS PRIOR TO INSTALLATION OF THE SYSTEM (i) Indemnity (a)SolarCity's Obligation to Install and Lease To the fullest extentermitted b law,you shall p Y SolarCity's obli atlons.to install and lease the System are Y g Y indemnify,defend,protect,save and hold harmless conditioned on the following items having been completed SolarCity, its employees,officers,directors;`agents, to its reasonable satisfaction: successors and assigns from any and all third party claims,actions,costs,expenses(including reasonable {i) completion of(A)the engineering site audit attorneys'fees and expenses),damages, liabilities, (a thorough physical inspection of the penalties,losses,obligations, injuries,demands and Property,including,if applicable, liens of any kind or nature arising out of,connected geotechnical work),(B)the final System with, relating to or resulting from your negligence or design,and(C)real estate due diligence to willful misconduct; provided,that nothing herein shall confirm the suitability of the Property for the require you to indemnify SolarCity for its own construction,installation and operation of negligence or willful misconduct.The provisions of this the System; paragraph shall survive termination or expiration of this Lease. (ii) approval of this Lease by SolarCity's financing partner(s); (j) Monthly Payments The Monthly Payments section(Section 4(13)) your meeting the applicable credit score; describes your monthly payment obligations under this Lease.YOU AGREE THAT THIS IS A NET LEASE AND (iv) confirmation of rebate,tax credit and THE OBLIGATION TO PAY"ACL MONTHLY PAYMENTS renewable energy credit payment availability AND ALL OTHER AMOUNTS DUE UNDER THIS LEASE in the amount used to calculate the Monthly SHALL BE ABSOLUTE AND UNCONDITIONAL UNDER Payment amounts set forth in this Lease; 0 0 SolarLease Agreement,version 7.1.3,February 15,2016 y 1672502 -_ ■ DocuSign Envelope ID:C8ED1554-E519-45D1-B5D1-1EIAEDE86FC2', (v) confirmation that SolarCity will obtain all 7. WARRANTY applicable benefits referred to in Section 9; YOU UNDERSTAND THAT THE SYSTEM IS WARRANTED° (vi) receipt of all necessary zoning,land use and SOLELY UNDER THE LIMITEDWARRANTYATTACHED AS building permits;and EXHIBIT 2,AND THAT THERE ARE NO OTHER REPRESENTATIONS OR WARRANTIES, EXPRESS OR (vii) completion of any renovations; IMPLIED,AS TO THE MERCHANTABILITY, FITNESS FOR ANY improvements or changes reasonably PURPOSE,CONDITION, DESIGN,CAPACITY,SUITABILITY OR required at your Home or on the Property PERFORMANCE OF THE SYSTEM OR ITS INSTALLATION. (e.g.removal of a tree or roof repairs necessary to enable SolarCity to safely install 8• TRANSFER the System);and SolarCity Works with banks, large companies and other significant financing partners to finance your System. As a (viii) if your home is governed by a home owner's result,SolarCity will assign this Lease to one of its financing association or similar community organization, partners. SolarCity may assign,sell or transfer the System your receipt of all approvals and authorizations and this Lease,or any part of this Lease or the exhibits, for the System required by that organization without your consent.Assignment,sale or transfer and advising us of any requirements of that generally means that SolarCity would transfer certain of its, organization that will otherwise impact the rights and certain of its obligations under this Lease to System,its installation or operation. ' another party. This assignment does not change SolarCity may terminate this Lease without liability if,in,its SolarCity's obligation to maintain and repair your System reasonable judgment,any of the'above listed conditions(i), as set forth in the Limited Warranty. . through(vi)will not be satisfied for reasons beyond its reasonable control. Once SolarCity starts installation, 9. OWNERSHIP OF THE SYSTEM;TAX CREDITS AND REBATES however,it may not terminate this Lease for the failure to satisfy conditions(i)through(vi)above. You agree that the System is SolarCity's personal property (b)Amendments,Your Right to Terminate for Material under the Uniform Commercial Code. You understand and Chanes,' agree that this is a lease and not a sale agreement, g SolarCity owns the System for all purposes,including any Both parties will have the right to terminate this Lease, data generated from the System.You shall at all times without penalty or fee,if SolarCity determines after the keep the System free and clear of all liens,claims, levies engineering site audit of your Home that it has and legal processes not created by SolarCity,and shall at misestimated by more than ten percent(10%)any of(i)the your expense protect and defend SolarCity against the System size;"(ii)the System's total cost or(iii)the System's same. annual production.Such termination right will expire at the earlier of(A)one(1)week prior to the scheduled System YOU UNDERSTAND AND AGREE THAT ANY AND ALL TAX installation date and(B)one(1)month after we inform you CREDITS, INCENTIVES, RENEWABLE ENERGY CREDITS, in writing of the revised size,cost or production estimate. GREEN TAGS,CARBON OFFSET CREDITS, UTILITY REBATESf If neither party exercises their right to terminate this Lease OR ANY OTHER NON-POWER ATTRIBUTES OF THE SYSTEM following such a 10%change,then any changes to the ARE THE PROPERTY OF AND FOR THE BENEFIT OF System will be documented,-in an amendment to this SOLARCITY, USABLE AT ITS SOLE DISCRETION.SOILARCITY Lease. You authorize SolarCity to make corrections to the SHALL HAVE THE EXCLUSIVE RIGHT TO ENJOY AND USE ALL utility paperwork to conform to thi"s Lease or any SUCH BENEFITS,WHETHER SUCH BENEFITS EXIST NOW OR amendments to this Lease we both sign. IN THE FUTURE. YOU AGREE TO REFRAIN FROM ENTERING INTO ANY AGREEMENT WITH YOUR UTILITY THAT WOULD ENTITLE YOUR UTILITY TO CLAIM ANY SUCH BENEFITS.` YOU AGREE TO REASONABLY COOPERATE WITH SOLARCITY 1672502 e A reement,version 7:13,Febr6a 15,2016 il R1 L DocuSign Envelope ID:C8ED1554-E519-45D1-B5D1-1E1AEDE86FC2'. SO THAT IT MAY CLAIM ANY TAX CREDITS,RENEWABLE writing after we send you the renewal forms,then this ENERGY CREDITS, REBATES,CARBON OFFSET;CREDITS OR- Lease shall renew for an additional one(1)year term at ANY OTHER BENEFITS FROM THE SYSTEM.THIS MAY ten percent(10%)less than the then-current average rate INCLUDE,TO THE EXTENT ALLOWABLE BY LAW,ENTERING charged by your local utility and shall continue to renew INTO NET METERING AGREEMENTS,INTERCONNECTION for one(1)year term's at that same rate until(i)you give AGREEMENTS,AND FILING RENEWABLE ENERGY/CARBON us notice at least thirty(30)days prior to a renewal term OFFSET CREDIT REGISTRATIONS AND/OR APPLICATIONS that you do not wish to renew;or(ii)we send you a FOR REBATES FROM THE FEDERAL,STATE OR LOCAL notice terminating the Lease. GOVERNMENT OR A LOCAL UTILITY AND GIVING THESE TAX CREDITS RENEWABLE ENERGY/CARBON CREDITS, 12. SELLING YOUR HOME REBATES OR OTHER BENEFITS TO SOLARCITY. (a) If you sell your Home you can: You understand that solar renewable energy credits - (SRECs)and associated data cannot be generated without (i)Transfer this tease and the Monthly Payments. intern et. As such,you agree to maintain and make The person buying your Home(the"Home available,at your cost,a functioning indoor Internet Buyer")can sign a transfer agreement assuming connection with the understanding that Wi-Fi hotspotting, all of your rights and obligations under this tethering and intermittent Internet connection will'not Agreement by qualifying in one of three ways: satisfy this obligation. You also agree to cooperate with 1) The Home Buyer has a FICO score of 650 SolarCity as necessary to provide any other information or greater; required to generate SRECs and troubleshoot monitoring 2) The Home Buyer is paying cash for your issues. Your failure to cooperate with SolarCity with Home;or respect to Internet requirements will result,in your 3) If the Home Buyer does not qualify'under obligation to compensate SolarCity for all lost SREC (1)or(2),the Home Buyer qualifies for a revenue and related costs,subject to a monthly charge of mortgage to purchase your Home and no less than$10.00(ten dollars)per month until adequate either;you or the Home Buyer pays us a Internet monitoring is implemented or restored. $250 credit exception fee: 10. .PURCHASING THE SYSTEM PRIOR TO THE END OF THE (ii) Move the System to Your New Home. LEASE TERM If you are moving to a new home in the same You do not have.an option to purchase the System at the utility district,then where permitted by the local end of the Lease Term. utility,the System can be moved to your new home pursuant to the Limited Warranty.You will 11. RENEWAL, need to payall costs associated with relocating If you are in compliance with your Lease,you have the the System,execute and provide the same option to renew your Lease for up to ten(10)years in two access and ownership rights as provided for in (2)five(5)year renewal periods.We will send you this Lease and provide any third party consents f renewal forms three(3)months prior to the expiration of or releases required by SolarCity in connection the Lease Term,which forms shall set forth the new with the substitute premises. Monthly Payments due under the renewed Lease,based' (iii) Prepay this Lease and Transfer only the Use of on our assessment of the then current fair market value the System. of the System. If you want to renew,complete the, 'ry renewal forms and return them,to us at least one(1) At any time during the Lease Term,if the person buying your home does not meet SolarCity s month prior to the expiration of the Lease Term. In the event that you respond that you do not agree to the new credit requirements, butstili wants the System, then you can(A)prepay the payments remaining Monthly Payments,the Lease shall expire by its terms on on the Lease(See Section 16(i)(i)and(ii)),(B)add the termination date. If you'don't send us anything in r SolarLease Agreement,version 7.1.3,Februar 15, ,, Y, 2016 1672302 �, 3 DocuSign Envelope ID:C8ED1554-E51945D1-B5D1-1EIAEDE86FC2" the cost of the Lease to the price of your home; (e) EXCEPT AS SET FORTH IN THIS SECTION,YOU WILL and(C) have the person buying your Home sign a NOT SUBLEASE,ASSIGN,SELL,PLEDGE OR IN ANY transfer agreement to assume your rights and OTHER WAY TRANSFER YOUR INTEREST IN THE non-Monthly Payment obligations under this SYSTEM OR THIS LEASE WITHOUT OUR PRIOR Lease.The System stays at your Home,the WRITTEN CONSENT,WHICH SHALL NOT BE person buying your Home does not make any UNREASONABLY WITHHELD. Monthly Payments and has only to comply with the non-Monthly-Payment portions of this Lease. (b) You agree to give SolarCity at least fifteen(15)days 13. LOSS OR DAMAGE but not more than three(3)months'prior written (a) Unless you are grossly negligent,you intentionally notice if you want someone to assume your Lease damage the System,or damage or loss to the System obligations. In connection with this assumption,you, is caused by ball strikes,SolarCity will bear all of the your approved buyer and SolarCity shall execute a risk of loss,damage,theft,destruction or similar written transfer of this Lease.Unless we have occurrence to any or all of the System. Except as released you from your obligations in writing,you are expressly provided in this Lease, no loss,damage,theft still responsible for performing under this Lease.. If or destruction will excuse you from your obligations your buyer defaults on this Lease and we have not under this Lease, including Monthly Payments. yet signed the transfer agreement,you-will be '.. responsible for their default. We will release you (b) If there is loss,damage,theft,destruction or a similar from your obligations under this,Lease in writing occurrence affecting the System,and you are not in once we have a signed transfer agreement with the default of this Lease,you shall continue to timely person buying your Home(provided such person has make all Monthly Payments and Pay all other amounts been approved as a transferee by SolarCity in due under the Lease and,cooperate with SolarCity,at writing). SolarCity's sole cost and expense,to have the System repaired pursuant toahe Limited Warranty. (c) If you sell your Home and-can't comply with any of the options in subsection(a)above,you"will be in 14. LIMITATION OF LIABILITY default under this Lease: Section 12(a)includes a Home sale by your estate or heirs. (a) No Consequential Damages SOLARCITY'S LIABILITY TO YOU UNDER THIS LEASE (d) Free Assumability.This agreement is free of any SHALL BE LIMITED TO DIRECT,ACTUAL DAMAGES restrictions that would prevent the homeowner from ONLY.YOU AGREE THAT IN NO EVENT SHALL EITHER freely transferring their home("Property").SolarCity PARTY BE LIABLE TO THE OTHER FOR will not prohibit the sale,conveyance or refinancing CONSEQUE-NTIAL;INCIDENTAL,PUNITIVE, of the Property.SolarCity may choose to file in the EXEMPLARY,SPECIAL OR INDIRECT DAMAGES. real estate records a UCC-1 financing statement ("Fixture Filing")that preserves their rights in the (b) Actual Damages System.The Fixture Filing is intended only to give Except for claims under Section 5(i),neither party's: r notice of its rights relating to the System and'is not a liability to the other will exceed an amount equal to lien or encumbrance against the Property.SolarCity' the maximum amount that could be payable by you, shall explain the Fixture Filing to any subsequent under Section 16(i).Damages to your Home, purchasers of the Property and any related lenders as belongings or property resulting from the installation requested.SolarCity shall also accommodate' or operation of the System are covered in Section reasonable requests from lenders or title companies 6(c)of the Limited Warranty. to facilitate a purchase;financing or refinancing of the Property. � �• 04 0 SglaAease Agreement,version 7.1.3,February15,2016 1672502 a DocuSign Envelope ID:C8ED1554-E519-45D1-B5D1-1E1AEDE86FC2 15. DEFAULT (f) disconnect,turn off or take back the System by legal You will be in default under this Lease if any one of the process or self-help,but we'may not disturb the following occurs: _ , peace or violate the law; (a) you fail to make any payment when itis due and such (g) report such non-operational status of the System to failure continues for a period of ten(10)days; your utility, informing them that you are no longer net metering; . (b) you fail to perform any,material obligation that you (h) charge you a reasonable reconnection fee for have undertaken in this Lease(which includes doing something you have agreed not to do, like alter the reconnecting the System to your utility or turning System)and such failure continues for a period of your System back on after we disconnect or turn off the System due to your default; fourteen(14)days after written notice; (c) you or your guarantor have provided any false or (i) recover.from you(i)all accrued but unpaid Monthly misleading financial or other information to obtain Payments,taxes,late charges,penalties,interest and this Lease; all or any other sums then accrued or due and owing, plus(ii)the unpaid balance of the aggregate rent, (d) you assign,transfer,encumber,sublet or sell this each payment discounted to present value at 5%per Lease or any part of the System without SolarCity's annum, plus(iii)reasonable compensation,on a net prior written consent;or after tax basis assuming a tax rate of 35%,for the loss (e) you or any guarantor makes an assignment for the or recapture of(A)the investment tax credit equal to benefit of creditors,admits in writing its insolvency, thirty percent(30%)of the System cost,including files or there is filed against you or it a voluntary installation;and(B)accelerated depreciation over petition in bankruptcy,is adjudicated bankrupt or five(5)years equal to eighty five percent(85%)of the insolvent or undertakes or experiences'any System cost, including installation,and for the loss of substantially similar activity. any anticipated benefits pursuant to Section 9 of this Lease(SolarCity shall furnish you with a detailed 16. REMEDIES IN CASE OF DEFAULT calculation of such compensation if such a claim is made);or If this Lease is in default,we may take any one or more of the following actions. If the law requires us to do so,we (j)..e, use any other remedy available to us in this Lease or will give you notice and wait any period of time required by law. before taking any of these actions.We may: You agree to repay us for any reasonable amounts we pay (a) terminate this Lease and your rights to possess and to correct or cover your default.You also agree to use the System; reimburse us for any costs and expenses we incur relating to the,System's return resulting from early termination. By (b) suspend our performance under this Lease; choosing any one or more of these remedies,SolarCity (c) take any reasonable action to correct your default or does not give up its right to use another remedy. By to prevent our loss;any amount we pay will be added deciding not to use any remedy should this Lease be in to the amount you owe us and will be immediately default,SolarCity does not give up our right to use that due; remedy in case of a subsequent default. (d) require you,at your expense,to return the System or We may submit to credit reporting agencies(credit make it available to us in a reasonableT6nanner; bureaus)negative credit reports that would be reflected (e) proceed,by appropriate court action,to enforce on your credit record if you do not pay,-any amounts due performance of this Lease and to recover damages under this Lease as required. for your breach; 17. SYSTEM REMOVAL:RETURN . a ao SolarLease Agreement,version 7.1.3,February 15,2016 •' 1672502 / v DocuSign Envelope ID:C8ED1554-E51945D1-B5D1-1EIAEDE86FC2 , At the end of the Term or the termination of this-Lease,if award is higher than SolarCity's last written settlement. you have not renewed this Lease or exercised your offer your attorney's fees and costs will not be included. purchase option (if any)and you have not defaulted,then Only Disputes involving you andSolarCitymaybe addressed within ninety(90)days you agree to call SolarCity at the in the arbitration. Disputes must be brought in the name of telephone number listed in Section 7 of Exhibit 2 to an individual person or entity and must proceed on an schedule a convenient time for SolarCity to remove the individual-(non-class,none-representative) basis.The ' System from your Home at no cost to you. arbitrator will not award relief for or against anyone who is 18. APPLICABLE LAW;ARBITRATION not a party. If either of us arbitrates Dispute,neither of us,nor any other person,may pursue the Dispute in PLEASE READ THIS SECTION CAREFULLY.ARBITRATION arbitration as a class action,class arbitration,private REPLACES THE RIGHT TO GO TO COURT, INCLUDING THE attorney general action or other representative action, nor RIGHTTO A JURY AND THE RIGHT TO PARTICIPATE IN A may any such Dispute be pursued on your or our behalf in CLASS ACTION OR SIMILAR PROCEEDING. IN ARBITRATION, any litigation in any court.Claims regarding any Dispute and A DISPUTE IS RESOLVED BY AN ARBITRATOR INSTEAD OF A remedies sought as part of a class action,class arbitration, JUDGE OR JURY. private attorney general or other representative action are . The laws of the state where your Home is located shall ' subject to arbitration on an individual(non-class, non- govern this Lease without giving effect to conflict of laws' representative) basis,and the arbitrator may award relief'`, principles.We agree that any dispute,claim or only on an individual (non-class,non-representative).basis. disagreement between us(a"Dispute")shall be resolved This means that the arbitration may not address disputes exclusively by arbitration. involving other persons with disputes similar to the The arbitration,including the selecting of the arbitrator,will Disputes between you and SolarCity. be administered by JAMS,under its Streamlined Arbitration' The arbitrator shall have the authority to award any legal or Rules(the"Rules")by a single neutral arbitrator agreed on equitable remedy or relief that a court could order or grant by the parties within thirty(30)days of the commencement under this agreement.The arbitrator,however,is not of the arbitration. ,The arbitration will,be governed by the. authorized to change or alter the terms of this agreement Federal Arbitration Act(Title 9 of the U.S.Code). Either or to make any award that would extend to any transaction party may initiate the arbitration process byfiling the other than-yours.All statutes of limitations that are necessary'forms with JAMS.To learn more about applicable to any dispute shall.apply to any arbitration arbitration,you can call any JAMS office or review the between us. The Arbitrator will issue a decision or award in materials at www.jamsadr.com.The arbitration shall be writing,briefly stating' the essential findings of fact and held in the location that is most convenient to your Home. conclusions of law. If aJAMS office does not exist within fifty(50)miles of your BECAUSE YOU AN6 WE HAVE AGREED TO ARBITRATE ALL Home;then we will use another accredited arbitration DISPUTES,NEITHER OF US WILL HAVE THE RIGHT TO provider with offices close to your Home. LITIGATE THAT DISPUTE IN COURT,OR TO HAVE A JURY If you initiate the arbitration,you will be required to pay TRIAL ON THAT DISPUTE,OR ENGAGE IN DISCOVERY the first$125 of any filing fee. We will.pay any filing fees in EXCEPT AS PROVIDED FOR IN THE RULES. FURTHER,YOU excess of$125 and we will pay all of the arbitration'fees WILL NOT HAVE THE RIGHT TO PARTICIPATE AS A and costs. If we initiate the arbitration,we will pay all of REPRESENTATIVE OR MEMBER OF ANY CLASS PERTAINING the filing fees and all of the arbitration fees and costs. We TO ANY DISPUTE.THE ARBITRATOR'S DECISION WILL BE will each bear all of our own attorney's fees`ancl costs FINAL AND BINDING ON THE PARTIES AND MAY BE except that you are entitled to recover your attorney's.fees ENTERED AND ENFORCED IN ANY COURT HAVING and costs if you prevail in the arbitration and the award you. JURISDICTION, EXCEPT TO THE EXTENT IT IS SUBJECT TO receive from the arbitrator is higher than SolarCity's last ' REVIEW IN ACCORDANCE WITH APPLICABLE LAW , written settlement offer. When determining whether your GOVERNING ARBITRATION AWARDS.OTHER RIGHTS THAT SolarLease ,,A reementversion 7.1.3Febru ; Agreement, ary 15,2016 ■ ON 1972502 ,. � , ❑ ' DocuSign Envelope ID:C8ED1554-E51945D1-B5D1-1E1AEDE86FC2 YOU OR WE WOULD HAVE IN COURT MAY ALSONOT BE AVAILABLE IN ARBITRATION: 19. WAIVER Any delay or failure of a party to enforce any of the provisions of this Lease,including but not limited to any ,remedieslisted in this Lease,,or to require performance by ` the other party of any of the provisions of this Lease,shall not be construed to(i)be a waiver of such provisions or a party's right to enforce that provision;or(ii)affect the validity of this Lease. 20. NOTICES All notices under this Lease shall be in writing and shall be by personal delivery,facsimile transmission,electronic mail,overnight courier,or certified,or registered mail,` return receipt requested,and deemed received upon personal delivery,acknowledgment of receipt of electronic transmission,the promised delivery date after deposit with overnight courier,or five(5)days after deposit in the mail'. Notices shall be sent to the person identified in this Lease at the addresses set forth in this Lease or such other r address as either party may specify in writing, Each party shall deem a document faxed or sent via PDF as an original document. 21. ENTIRE AGREEMENT,CHANGES This Lease contains the parties'entire agreement regarding the lease of the System. There are no other agreements regarding this Lease,either written or oral. Any change to this Lease must be in writing and signed by both parties.Only an authorized officer of SolarCity may execute any change to this Lease on behalf of SolarCity. If any portion of this Lease is determined to be unenforceable,the remaining provisions shall be enforced in accordance with their terms or shall be interpreted or re-written so as to make them enforceable. REST OF PAGE INTENTIONALLY LEFT BLANK 1 r li ps SolarLease Agreement,version 7.1.3,February 15,2016 ' 1"672502 J DocuSign Envelope ID:C8ED1554-E519-45D1-B5D1-1E1AEDE86FC2 , 22. PRIVACY/PUBLICITY 1 have read this Lease and the Exhibits,in their entirety and I You grant SolarCity the right to publicly use,display,share; acknowledge that I have received a complete copy of this and advertise the photographic images, Project details, Lease. price and any other-don-personally identifying information of your Project.SolarCity shall not knowingly release any personally identifiable information about you or any data Customer's Name:John Conides associating you with the Project location.You may opt-out —DocuSigned by: of these publicity rights by giving us written notice and �b CblatdtS. mailing it to:SolarCity Corporation,Attention: Publicity Opt Signature: E56EB0442M3451... Out,3055 Clearview Way,San Mateo,CA 94402. Date: 3/18/2016 23. NOTICE OF RIGHT TO CANCEL YOU MAY CANCEL THIS LEASE AT ANY TIME PRIOR TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE DATE Customer's Name: YOU SIGN THIS LEASE.SEE EXHIBIT 1,THE ATTACHED NOTICE OF CANCELLATION FORM,FOR AN EXPLANATION Signature: OF THIS RIGHT. Date: 24. ADDITIONAL RIGHTS TO CANCEL IN ADDITION TO ANY RIGHTS YOU MAY HAVE TO CANCEL THIS LEASE UNDER SECTIONS 6 AND 23,YOU MAY ALSO SolarLease Agreement CANCEL THIS LEASE AT NO COST AT ANY TIME PRIOR TO COMMENCEMENT OF CONSTRUCTION ON YOUR HOME: Sofia rCity 25. Pricing ' The pricing in this Lease is valid for 30 days after a pp`roved 3/18/2016. If you don't sign this Lease and return it to us on or prior to 30 days after 3/18/2016,SolarCity reserves- the right to reject this Lease unless you agree to our then Signature: current pricing. Lyndon Rive, CEO Date: 3/18/2016 f i SolarLease Agreement,version 7.1.3,February 15,2016 1672502 /,- DocuSign Envelope ID:C8ED1554-E519-45D1-B5D1-1E1AEDE86FC2 EXHIBIT 1(SOLARCITY COPY) NOTICE OF CANCELLATION STATUTORILY-REQUIRED-LANGUAGE Notice of Cancellation Date of Transaction:The date you signed the'Lease. You may CANCEL this transaction,without any penalty or obligation,within THREE BUSINESS DAYS from the above date. If you cancel,any property traded in,any payments made by you under the contract or sale and any negotiable instrument executed by you will be returned within TEN DAYS following receipt by the seller(SolarCity Corporation)of your cancellation notice,and any security interest arising out of the transaction will be canceled. If you cancel,'you must make available to the seller(SolarCity Corporation)at your residence,in substantially as good condition as when received,any goods delivered to you under this contract or sale,or you may,if you wish,comply with the instructions of the seller(SolarCity Corporation)regarding the return shipment of the goods at the seller's(SolarCity Corporation's)expense and risk. If you do make the goods available to the seller (SolarCity Corporation)and the seller(SolarCity Corporation)does not pick them up within 20 days of the date of your notice of cancellation,you may retain or dispose of the goods without any further obligation. If you fail to make the goods available to the seller(SolarCity Corporation),or if you agree to returri:the goods to the seller(SolarCity Corporation)and fail to do so,then you remain liable for performance of all obligations under the contract. To cancel this transaction,mail or deliver a signed and dated copy of this cancellation notice,or any other written notice,or send a telegram to SolarCity Corporation,Document Receiving,6611 Las Vegas Blvd.S.,Unit 200,Las Vegas,NV 89119 NOT LATER THAN MIDNIGHT of the date that is THREE BUSINESS DAYS from the date you signed the Lease. I,John Conides,hereby cancel this transaction on [Date]. Customer's Signature: { Customer's Signature: SolarLease Agreement,version 7.1.3,February 15,2016. 1672502 DocuSign Envelope ID:C8ED1554-E519-45D1-B5D1-1EIAEDE86FC2 EXHIBIT 1(CUSTOMER COPY) NOTICE OF CANCELLATION STATUTORILY-REQUIRED LANGUAGE Notice of Cancellation , Date of Transaction:The date you signed the Lease: You may CANCEL this transaction,without any penalty or obligation,within THREE BUSINESS DAYS from the above date. If you cancel,any property traded in,any payments made by you under the contract or sale and any negotiable instrument executed by you will be returned within TEN DAYS following receipt by the seller(SolarCity'Corporation)of your cancellation notice,and any security interest arising out of the transaction will be canceled. If you cancel,you must make available to the seller(SolarCity Corporation)at your residence,in substantially as good condition as when received,any goods delivered to you under this contract or sale,or you may,if you wish,comply with the instructions of the seller(SolarCity Corporation)regarding the return shipment of the goods at the seller's(SolarCity Corporation's)expense and risk. If you do make the goods available to the seller (SolarCity Corporation)and the seller(SolarCity Corporation)does not pick them up within 20 days of the date of your notice of cancellation,you may retain or dispose of the goods without any further obligation. If you fail to make the goods available to the seller(SolarCity Corporation),or if you agree to return the goods to the seller(SolarCity Corporation)and fail to do so,then you, remain liable for performance of all obligations under the contract. To cancel this transaction,mail or deliver a signed and dated copy of this cancellation notice,or any other written notice,or send a telegram to SolarCity Corporation,Document Receiving,6611 Las Vegas Blvd.S.,Unit 200,Las Vegas,NV 89119 NOT LATER THAN MIDNIGHT of the date that is THREE BUSINESS DAYS from the date you signed the Lease. I,John Conides,hereby cancel this transaction on [Date]. Customer's Signature: Customer's Signature: r z SolarLease Agreement,ver2sion 7.1.3,February 1S,2016 1672502 A DocuSign Envelope ID:C8ED1554-E519-45D1-B5D1-1E1AEDE86FC2 Exhibit 2 PERFORMANCE GUARANTEE AND LIMITED WARRANTY 1. INTRODUCTION This Performance Guarantee and,Limited WarrantY(this""Limited Warranty")Is SolarCi t s agreement to provide you warranties on the System you leased. The System will be professionally installed by SolarCity at the address you listed in the Lease.We will refer to the installation location as your"Property"or your"Home." This Limited Warranty begins when we start the survey of your Home for the System. We look forward to helping you produce clean,renewable solar power at your Home. 2. LIMITED WARRANTIES,PERFORMANCE GUARANTEE (a) Limited Warranties (i) System Warranty Under normal use and service conditions the System will be free from defects in workmanship or defects in,or a breakdown of,materials or components,for the full Term; (ii) Roof Warranty All roof penetrations we make for your System will be watertight.This warranty will run the longer of(a)the first ten (10)years of the Term.or-(b)the length of any existing installation warranty or new home builder performance standard for your roof; - (iii) Damage Warranty We will repair damage we cause to your Home,your belongings or your property or pay you for the damage we cause,as limited by Section 6,;for the full Term(except damages that result from our roof penetrations,which damages are covered for the first ten(10)years of the Term). Under each of these warranties SolarCity will repair or replace any damage,defective part,material or component or correct any defective workmanship,at no cost or expense to you(including all labor costs),when' you submit"a valid claim to us under this Limited Warranty. SolarCity may use new or reconditioned parts when making repairs or replacements.SolarCity may also,at no additional cost to you,upgrade or add to any part of the System to ensure that it performs according to the guarantees set forth in this Limited Warranty. Cosmetic repairs that do not involve safety or performance shall be made at SolarCity's discretion. ; (b) Performance Guarantee (i) Power Production Guarantee SolarCity guarantees that during the Lease Term the System will generate kilowatt-hours(kWh)asset forth in the table below and calculated as follows.To calculate the guaranteed amount of kWh for an applicable two-year period ("Guaranteed kWh")we will take the applicable year's Total kWh in the chart below minus the Total kWh from two years prior,also as indicated in the chart below: SolarLease Agreement,version 7.1.3,February 15,2016 1672502 ■ DocuSign Envelope ID:C8ED1554-E519-45D1-B5D1-1E1AEDE86FC2'. SolarCitty SolarLease,- Customer Name and Address Installation Location, Date John Conides 874 Salem St 3/18/2016 874 Salem St North Andover,MA 01845 North Andover,MA 01845 Here are the key terms of your Solar ease Agreement ; I I l...i- 0 ' U Amount due at contract signing First year mon 0ayment �. A reem 6 m `J (Est.pace per kwh F rsI car: 0.1504) � A/' Initial here Initial here -,J(�_ D The SolarCity Promise DS •We provide a money-back energy performance guarantee. JL •We guarantee that if you sell your Home,the buyer will qualify to assume your Agreement. ........................... .. ................Initial here__.___ •We warrant all of our roofing work. ` Ds •We restore your roof at the end of the Agreement., �C •We warrant, insure and repair the System. ..,..:... .................................( .....:::.................................... .................................... ....... Initial her •We fix or pay for any damage we may cause to your property: •We provide 24/7 web-enobled monitoring at no additional cost. •The rate you pay us will remain fixed for the term of the Agreement. •The pricing in this Agreement is valid for 30 days after 3/18/2016. ' !� Your SolarCity Lease Agreement Details Your Choices at the End of the Initial "Your Prepayment Choices During Amount due at contract signing . Term: the Term: 1 $0 •SolarCity will remove the System at no : • If you move,you may prepay the Est.amount due at installation additional cost to you. remaining payments(if any)at a $0 •You can upgrade to a new System with discount. the latest solar technology under a new Est.amount due at building inspection contract. $0 g •You may renew your Agreement for up to Est.first year production ten(10)years in two(2)five(5)year 7,759 kWh increments. •Otherwise,the Agreement will automatically renew for an additional one (1)year term at 10%less than the then- current average rate charges by your local utility. 3055 Clearview Way,San Mateo,CA 94402 888.765.2489 1 solarcity.com ' 1672502 SolarLease Agreement,version 7.1.3,February 15,2016, SAPC/SEFA Compliant a Contractor License MA HIC 168572/EL 1136MR; Document generated on 3/18/2016 f ❑ . ,;copyright 2008-2015 SolarCity Corporation,All Rights Reserved ■ DocuSign Envelope ID:C8ED1554-E519-45D1-B5D1-1EIAEDE86FC2'' 22. PRIVACY/PUBLICITY I have read this Lease and the Exhibits,in their entirety and I You grant SolarCity the right to publicly use,display,share, acknowledge that I have received a complete copy of this and advertise the photographic images, Project details, Lease. price and any other non-personally identifying information of your Project.SolarCity shall not knowingly release any personally identifiable information about you or any data Customer's Name:John Conides associating you with the Project location.You may opt-out DocuSigned by:. of these publicity rights by giving us written notice and mailing it to:SolarCity Corporation,Attention: Publicity Opt Signature: E56E60442A53451... Out,3055 Clearview Way,San Mateo,CA 94402. Date: _..3.3/18/2016 23. NOTICE OF RIGHT TO CANCEL YOU MAY CANCEL THIS LEASE AT ANY TIME PRIOR TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE DATE Customer's Name: YOU SIGN THIS LEASE.SEE EXHIBIT 1,THE ATTACHED NOTICE OF CANCELLATION FORM,FOR AN EXPLANATION Signature: OF THIS RIGHT. Date: 24. ADDITIONAL RIGHTS TO CANCEL IN ADDITION TO ANY RIGHTS YOU MAY HAVE TO CANCEL THIS LEASE UNDER SECTIONS 6 AND 23,YOU MAY ALSO SolarLease Agreement CANCEL THIS LEASE AT NO COST AT ANY TIME PRIOR TO COMMENCEMENT OF CONSTRUCTION ON YOUR HOME: • ty 25. Pricing Solaro The pricing in this Lease is valid for 30 days after approved 3/18/2016. If you don't sign this Lease and return it to us on or prior to 30 days after 3/18/2016,SolarCity reserves •^, the right to reject this Lease"unless you agree to our then Signature: { current pricing. ` LyndOn Rive, CEO Date: 3/18/2016 o ti - Sola'rtease Agreement,version 7.1.3,February 15,2016 1672502 T z ❑ The Comm nhaealth ofMassachaseft Depariment of IndustrialAccidents Office of Invest€gad ms ' I Congress Sir=e Su to 100 Bastortr MA 02114-20.17 www tnass gov/dia Workers'Compensation InsuranceAffidevit:Builders/Contractors/Electricians/Plumbers Ailiplicant 111formagen Tease Print Le ibl NaMe(13usincss/0rganizationlfndividual), SolarCity Corp. Address: 3055 Clearview Way City/Stategip: San Mateo CA. 94402 Phone#.888-765-2489 Are you an ehmployer7 Check the appropriate boa: Type or project(required): 1.Q✓ l am a employer with.15,000 4. [l I ant a general contractor and 1 mploycos(full andlar part-time),' have hired the sub-contractors eNew construction 2.❑ arts a sole proprietor or partner- listed on the attached sheet. 7. []Remodeling ship and have no employees Theso subcontractors have g. Q Demolition working far the in any capacity, employees and have workers' [Noworlcers' comp. insurance comp,inswance.3 4. ©Building addition required.] S. We are a corporation and its 10.[]Electrical repairs or additions 3.❑ 1 am a homeowner doing all work officers have exercised their 11,E]Plumbing repairs or additions trtybolL [No worlds' comp. rfptlitoi xentptiont per kYRVL 12,0 Roof repairs insurance required,)t c. 152,§1(4),and we have no employees.[No workers' 13[✓ Other Solar/PV comp. insurance required.] "Any applicant that checks boxfl f must also fill out the scetina botow showing their workas'wmpcnsotion policy information. t Homeowners who submit this affidavit itidfcating they are doing all v6vrk and then hire outs"tdc contractors must submit it new affidavit indicating suet+, rContrnctors that check this box Hurst attached on additional sheet showing the name of the sub•contractots and stn:to whether or not those entities havo employees. ffthesub•contraetors have employees,they utust provide their workers'comp policy number. Y gulf an employer drat is providing workers'compensation.Insurance for my employees. Below Is the policy acid job site information. Insurance Company Name: Zurich American Insurance Company Policy#or Selt-ins.l ic.#: WC01820115-00 Expiration Date: 9/1/2016� " � Job Site Address: City/State/'Gip: N•a,&J9d'./nA 018,15 Attach a eopyof the workers' cofnpeuttation policy declaration page(showing the policy number and expiration date). Fzilurs to secure coverage as required under Section 25A of NGL c. I52 can lead to the imposition of criminal penalties of a fine up to S1,500.00 and/or one-year imprisorunent,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to 1250.00-a day against the violator. Be advised that a copy of this statement may use forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby cert yy the pains and penaNies of periary that the infornfaden provrrded above Is true and correct 5i ' atu Date: a`l Phone '' Ofeietal»ase only. Leo not write in this area,to be completed by city or low$ojjicial, City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.CitylTown Cterk 4.Electrical inspector 5.Plumbing Inspector 6.other Contact Person: Phone#; ��op� DAT E(MWDD;YYYVj � CERTIFICATE OF LIABILITY INSURANCE �r17rz�15 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER, THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION 1S WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT MARSH RISK& INSURANCE SERVICES NA_,ME.-..-...-.__._......... ._. _.,Fax.. ..... aHorl> -. ._... 345 CALIFORNIA STREET,SUITE 1300 lAtC.tlfLJ3xI1—......._........_. .. ... ... ..... . . ........:.{nuc,evo):. ......... ......... ................... CALIFORNIA LICENSE NO.0437153 E-MAIL SAN FRANCISCO,CA 94104 _aouRg5�:. ..... .............. ... ..... .. ............... ............ ........ ......... ........T........................._.. Atli:Shannon Scott 415-143.8334 ..........INSURER.iq AFFORDING COVERAGE. ... . .. ... ......._....+... NAIC# 99DOI A;Zurich American Insurance Company 16535 _ ._......__........... ... .. ........... ...... .... ............ .... .......... ....... ........... ...... .. ............._. ........ _.. ... . ..._ .. INSURED INSURER 8:NIA NIA SolarCiV Corporation ....._. +. .. ....... .... 3059 Clearview Way INSURER c:NIA NIA San Mateo,CA 94402 rNSURER.D:American Zurich Insurance Company 40142 IIQSURER E: ENSURER F: COVERAGES CERTIFICATE NUMBER: SEA-00271383MB REVISION NUMBER:4 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADOL.SUBR POLICY EFF POLICY EXP LIMITS LFR POLICY NUMI3ER I MMIDD Y MMIDDI YY A X COMMERCIAL GENERAL LIABILITY iGL00182016-00 0010112015 `091011201$ EACH OCCURRENCES 3,60D,C00 _.� �...... DAMAGE TQIiEN'fED..._..... .;. ........ ...........__..._.._.. CLAWS-MADE ,OCCURRRFMISES(Eaoaurresce�,,,.;_5 ,.. .____.-.._.3,000,000 X X 502:$250,000 MED ExP(Any one person) S ............................................. . . . ..... 5,000 3,000,000 i .............. .................__........_............. PERSONAL&ADV INJURY -S GEN'L AGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE 5 ....., ,....._ 6,000,000 I.._.. PRO- [ F X POLICY:. .. JE CT LOC i PRODUCTS•COMPIOP AGG:$ 6,000,000 OTHER S A AUTOMOBILE LIABILITY 'BAP0182017.00 :0910112015 09101(201fi C BINED SI GLE LIMIT $ 5,000,OOD X ANY AUTO BODILY INJURY(Per person) $ ,.. ..1 ALL OWNED SCHEDULED ,..... .. . ........ ........ _ X X ;BODILY INJURY(Per accrdent)'$ ,.. ..i AUTOS r.... AUTOS � ............. ...... _ ... X X NON-OV+MED ARaPERTYDANIAGE $ f. ....1 HIRED AUTOS F... AUTOS F{Peraccjdent}. ..... ..._ .....+.. .. ...... .................... _ COMPICOLL DED_ $ $5,000 UMBRELLA LIAB OCCUR I EACH OCCURRENCE $ E7(CESSLIAB CLAIMS-MADE AGGREGATE 3 j.... r.... .r... ....._..1. ...i.....---.....---1 ....... ... .. {..... ... .............. DED RETENTIONS i ;£ D 'WORKERS COMPENSATION WC0182014.00(AOS) :0910112015 0910112016 i X PER DTH- IAND EMPLOYERS'LIABILITY A Y/Nj W130182015.00 MA 0910112015 0910112016 E L EACH ANY PROPRIETORIPARTNERIEXECUTIVE ) ACCIDENT �$ ,1,000,000 OFFiCERIMEMBER EXCLUDED �;NIA:. r-....---..._._....... .. ... ....�. . .. . ... . (Mandatory In NW} I WC DEDUCTIBLE;$500,000 E.L DISEASE-EA EMPLOYE s 1.000,000 If es.dew be under I _._........_..... .... . ...... ...�._.... ._. . . ... ...".... DESCRIPTION OF OPERATIONS below I E L DISEASE-POLICY LIMIT is 1,000,000 i i DESCRIPTION OF OPERATIONS I LOCATIONS 1 VEHICLES (ACORD 401,Additional Remarks Schedule,may be attached II more space is requ{red) Evidence of insurance. CERTIFICATE HOLDER CANCELLATION SolarC4 Corporation SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 3055 Clearview Way THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED 1N San Mateo,CA 99402 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE or Marsh Risk&Insurance Services CharlesMarmolejo - � 41988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014101) The ACORD name and logo are registered marks of ACORD /X - Office of Consumer Affairs and Business Regulation ` 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 168572 Type: Supplement Card SOLAR CITY CORPORATION Expiration: 3/8/2017 . DAN FONZI - ------ -- - -- - 24 ST MARTIN STREET BLD 2UNIT 11 --- - -- ---- MARLBOROUGH, MA 01752 Update Address and return card.Mark reason for change. [] Address E] Renewal ❑ Employment Lost Card ", "f3ftice of Consumer Affairs&Business Regulation License or registration valid for individul use only ` r140ME IMPROVEMENT CONTRACTOR before the expiration date. If found return to: "` Office of Consumer Affairs and Business Regulation Registration: 168572 Type: 10 Park Plaza-Suite 5170 Expiration: 3/8/2017 Supplement Card Boston,MA 02116 SOLAR CITY CORPORATION DAN FONZI 3055 CLEARVIEW WAY SAN MATED,CA 94402 Undersecretary Not valid without signature + E'�ares:.'Rui:..'.Y3 Rt�ulatlG.::, ar••aS:,tn��;":3: �Eccrrse CS-1D1687 DANIEL D FON2I-' �+.-.. 15 KELLEY RD WILMINGTON MA 01887 Comrfva s::nrvW� 09/13/2016 F Solar 0 0 Single Phase Inverters for North America S Q I e 0 Xo & SE3000A US/SE3800A US/SE5000A US/SE6000A-US/ r� SE760OA-US/SE1000OA-US/SE1140OA-US �. SE3000A-US SE3800A-US .SES000A-US �SE6000A U.. SE7600A-US, SE..... US SE31400A US OUTPUT So l a r E d g e Single Phase Inverters - Nominal AC Power Output 3000 I 3800 5000_ 6000 7600 10000 240V. 11400 VA 5400 @ 208V 10800 @ 208V ` Max.AC Power Output 3300 4150 5450,,@240V, 6000 8350 10950,4x1,240V 12000 VA For North America AC Output Voltage Min:Nom.Max.(tI 183 208--229 Vac..................... ...... . .. . ............... ......... .. ... ...... ....._.. SE3000A-US/ SE380OA-US/SE5000A-US/SE60O0A-US/ AC Output Voltage Mln:Nom.Max!tI 211-240 264 Vac SE76OOA-US/SE1O000A-US/SE114OOA-US ................ ... ... _ . .. ... ...... .. ... . . . ...... . .. .. .. ... .. ... .. .... . . . ... . '' r '` r cy Min-N m Max t( 3 60-60.5 co 57 - 5j .-, Hz .....................:............:...... ..... .. .. .. 9.-24 @ 208V(with .. ........ ..... ..... 60.48 @ 208V... AC Frequency o ( 5 ith HI country setting 60. `I �. ...... ....... .............. ...........: -1 .21.V.24�y..-I.. - ....I.....-..._.....i ..42.@.240V .. . : .. Continuous Output Current 12 5 16 25 32 47 5 A ... .. .... ... .. .. .... ......... .1 .... ... .. .A.,... r r .... . 4 - _IMonitoring,IsIandIng Protection Country Configurable Thresholds Yes - Yes NPUT _ Maximum DC Power(S7C) 4050 _'.,.m.5100._., 6750 -. ._8100 ,.. ., ,10250-.-,-1 ...13500, -T ,15350,.- Transformer-less,Ungrounded _Yes 25 ti. _ . . ..... ......... .. ..... .... . .......... ....... . . . ... ..... .. ... ..... . 1 a Wil. Max.Input Voltage..... .-I..-. S00 Vdc 2 acs .. . ... ... . . . Wanes tj - - _. s !z - - Nom.DC Input Voltage 325 @ 208V/350 @ 240V ,- ,., a�J-,�7 Max.Input Current(2) .9 5 .I ..,.13.... 15.5 @ 240V.. . .....18 -23. .. ..I. 30.5@�°20�V. 34.5.. Adc... ,as adc. _...._. .............. . . . . . . . .. ... . ...... Max.Input Short Current I . tic Ye so ationcDetection.... .. ...... .. .. .. .. .. ... ...... .600kst Sensitivity.............. _. f : a ,.::__ a. fu = ;• s` Maximumd-alnverter Efficienc......... 97.7 I.. . 98.2.. ....98.3.. ....98.3... .....98.... .98..... ... .98 -..�...-. .. € .. ..a. . .. . .. . ... . . . ... ... ..... . I... ...... .... ....... .. 98 2 . 975 98 � 97.5@208V � 7S 97@208VI o Weighted Efficiency - @ _ .... . . . . . .... . ...... L. ... y..i.. ............ ... .. .... . �.. CEC -d Ffficil 97 5 9 97 5 Y .! . Nighttime Power Consumption - _. -_..-----.-____.____. -98 @ 5 0 -._..-. .--.--...�_.. _. <4 -...__...._....._.W.._._ i I 1ADDITIONAL FEATURES___ Supported Communication Interfaces( RS485,RS232,Ethernet,Zig Bee(optional) _ .. .. .. ......... t Revenue Grade Data,ANSI C12.. l Optional `-� � - Functionality enabled when SolarEdge rapid shutdown kit Is installed(s) - H a STAN =- Mm", t Safety 2 .. .. . . . .. .. Shutdown NEC 2014 690 1 I RD COMPLIANCE .. ......... .... 996 UL19 Grid Connection Standards i t6IEEE1547 98 - - ;, _ �; _ Emissions....... ...... .. 1. FCC part15 class B CS _ ..........___..__ U L174 A 22 2 _ _�_ ........ _ _ . ..._.... __._, s INSTALLATION SPECIFICATIONS _ y R output size/AW range 3/4" m/16 3/4" m/8 - � AC conduit si G minimum 6 AWG minimum 3 AWG input conduit size/#of strings .. ..... ........ .. ... ... ............ ..3/4"minimum/1-2 strings/ ..I.-.. 3/4"minimum/1-2 strings/16-6 AWG .. .. .. ... ....... 30.5 0 ........ .. .... .. .. ...... ... ...... ( 146 AWG. ., ... t _ _ Dimensions with Safety Switch 30.5 x].2.5 x 10.5/ In�.. (HxWxD) 5x184 75x315x.2 ....-., rnm_. �. a .. ................. ... ...... ... .. ... . .. ..... ... .. - - - s Weight with SafetySwitch 512/23.2 3154.7/24.7 -- - - - -- - 788.4/40.1 0 Ib/.kg, ......... ..... . . ........ .... ... .. . . ... ........... . . . . . .. .... .. .Natural .. Sx125x 72 775x e w ":: .. _ Cooling convection i in Natural Convection and internal I Fans(user replaceable) fan(user - i .. . . .. .. .. .. I-replaceable)... . . . .. . . . .... The best choice for SolarEdge enables! systems .0 .. . . . . . . . . . . . . ....... q ) � Noise ���� <25 <50 .- , dBA ii - Integrated arc fault protection(Type 1)for NEC 2011690.11 compliance. Mln.-Max Operating Temperature -13 to+140/-25 to+60 -40 to version available"') "F/-C Superior efficienc98% Range........................... . . . (.. . .. ...... .... .,.... . . . . ... . . ...... . . . . , Protection Rating NEMA 311 .herr-.onalseri.... eu ort Small,lightweight and easy to install on provided bracket p settings sed; heinv,arEdg pp A h gher current source may be used,the nverter will I m t Its input-rent to the values stated. i - Built-in module-level monitoringF (3l Revenue grade inverter P/N.SEx-AU5000NNR2(for 7600W nvertersE7600A-U5002NNR2). 3 (6I R p d shutdown kit P/N SE1000-1151 Sk - Internet Connection through Ethernet or Wireless ISI-40 version P/N SE-A-USOOONNU4 Ifor 7600W rter:SE7600AU5002NNU4). - Outdoor and indoor installation - Fixed voltage inverter,DC/AC conversion only - Pre-assembled Safety Switch for faster installation r-� II---ttl ffn--11 - Optional-revenue grade data,ANSI C12.1 sfarfsr c I �.1r1 - . USA-GERMANY-ITALY-FRANCE:.-JAPAN-CFIINA-AUSTRAL IA-THE NETHERLANDS-ISRAEL VVWW-SOlaredge.US tiTL-'(rCt3L - 1ui: 7s'�Ti1k 1Vi rr fir' - � 7C'I�'IiI'iLt�+Tf.�'LQ+�-iSvfL'1,-y'Ta-l�f�,rm�fr.7t-_.,�ya� • 'q]*r ,641T.7ttxsi7ti9'Sr*1:.�1GL•1etFGCClhaC:i l THE Irwimmmc unt MODULE TSM-PQ05.18 Mono Multi Solutions DIMENSIONS OF PV MODULE ELECTRICAL DATA C4i STC unU:mm Peak Power Watts-PMAx(WP) 245 250 255 260 941 rpt - ,Power Output Tolerance-PMAx(%) 0-+3 JUNCTION T �t f 1 1 o Maximum Power Voltage (v) 29.9 30.3 30.5 30.6 E- rl,0 U t `eo. �� `Maximum PowerCurrent-t-IlMPP(A) 8.20 8.27 8.37 8,50 NAMEPLATE Open Circuit Voltage-Voc(V) 37.8 38.0 38.1 38.2 Short Circuit Current-Isc(A) 8.75 8.79 8.88 9.00 r ��srnuiNC HOLE41 _ ter»/ DU LE Module Efficiency qm(%) 15.0 15.3 1 15.9 (/`�� STC:Irradiance 1000 W/m',Cell Temperature 25°C.Air Mass AM1.5 according to EN 60904-34-3. Typical efficiency reduction of 4.5%at 200 W/m'according to EN 60904-I. 0 ELECTRICAL DATA.a)NOCT y b IL Maximum Power-PMAx(WP) 182 186 190 193 jL4�yJ Ilt�.ar � I ^Maximum Power Voltage-VMP IV) 27.6 28.0 28.1 28.3 MULTICRYSTALLlNE MODULE 60x3-OUNDIND HOLE Maximum Power Current-IMPP(A) 6.59 6.65 6.74 6.84 ��,}'�TINAi�I }tNT �> ) ,s-DxAwNOLE A A Open Circuit Voltage.(V)-VocIV) 35.1 35.2 35.3 35.4 Short Circuit Current(A)-Isc(A) 7.07 7.10 7.17 7.27 " l .......... ...W....a...____.._._............ ..__._._,w_._..? NOCT:Irradiance at 800 W/m',Ambient Temperature 20°C,Wind Speed I m/s. � p PD05.18 8tz 80 g �J Back View POWER OUTPUT RANGE MECHANICAL DATA i !`'r Solar cells Multicrystalline 156 x 156 mm(6 inches) ._....®.___: / p s Fast and simple to install through drop in mounting solution f �t Cell orientation 60 cells(6 x 10). e GT f d Module dimensions 1650 x 992 x 40 mm(64.95 x 39.05 x 1.57 inches) «s*i+'lL d+ ii - Q Weight 21,3 kg.(47.0lbs) MAXIMUM EFFICIENCY Glass 3.2mm(0.13inches),HighTransmission,ARCoated'Tempered Glass E .�.. - A-A Backsheet - White - - I - ( Good aesthetics for residential applications Frame Black Anodized Aluminium Alloy with Trinamount Groove ' f�,�e Tt� "9 l V CURVES OF PV MODULE(245W) J-Box o rte _ ,. - � � T Cables Photovoltaic Technology cable 4.0 mm'(0.006 inches'). ... - .._ ......... ......... ........... .. ... .... ... ... ._.. ...-..- .._......_......_...... ...... to.m ' 1200 mm(47.2 inches) POWER OUTPUT GUARANTEE 9m 1000WFm; -- -_ 8. ��`.. m 7 Fire Rating Type W/m% Highly reliable due to stringent quality control _6 �6D - - d '..'v-r 30 in-h,1-,1.s :e #5 ,l, IC H and I a lti n I I c wowrm= T _ -- -- As o lel•",eC"7 glgiui rl.,iar14,fOC-ATE:` oXti{ .'EIC l 't C ol;moi; ) is..y ' lOill cgCca , .1L )tet a --£.!(IC-G':IC1 , am 08U W ' TEMPERATURE RATINGS MAXIMUM RATINGS 2m 200w/m' NominalOperaTing Cell Operational Temperature -40-+85°C C P Cl C s `. e IJ I lose ,_.. ' 44°C(*-2°C) Temperature(NOCT) r fr xtic nv,ith o"i,nr1 :Ire.; - 3 Maximum System 1000V DC(IEC) I,, .,.. .It1.,71:0_� c: ✓� :S. .tt Ic?GCI tom lo.- 20:- 30.- 40.- ;Temperature CoefficientofP.A. -0.41%/oC Voltage 1000VDC(UL) r,Qc n -.orC 1Cd 71 t I , r r 1 l5 Temperature Coefficient of Voc -0.32%/'C Max Series Fuse Rating 15A at o provide e;l f}11 :S yr eVoitage(V) ., merit eacn nnarke �` ' Certified to withstand challen in environmental TemperatureCoefflaentofIsc 0.05%/oC an COndltlfln5 rP r'r:nt TE J bl.`,pl`0r U C N JiTh Ili b c C k I 'p �"� • 4.;O l'a wind)load - r:.f Trir 7 cS aWARRANTY a: fir F r.Ytn11 :< ; 4C;)Pa n ,,, I•^-1< , fc,building rotes n- IUG•Ii, 0 year Product Workmanship Warranty oelleft seflabopotio�Will) 25 year Linear Power Warranty i cpw bulofs (Please refer to product warranty for details) ¢ cnci:#'rr3r klcir.>7<:rs r��tt c� 1= b 1 i k une -:o.jr Shard cALcc;ess it, CERTIFICATION driving rnar Erioi-jv Tr alhe, LINEAR PERFORMANCE WARRANTY PACKAGING CONFIGURATION ¢' _.._ ._..,.. _� 10 Year Product Warranty'25 Year Linear Power Warranty eLIMD ccus Modules per box:26 pieces �i w l Trina Solar Limited ss IN I Modules per 40'container:728 pieces a.i inDsvio :c:-r1 W00% �w ��-s� _ _ a is 3: far YL}{ Ell-3BWEEE v 90°6 ue fraryr Trtrta So{ar°${(Wept COMPLIANT h`errran{�, CAUTION.READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. paMP4rig "Td o ryId ®2014 Trino Solar Limited.All rights reserved.Specifications included in this datasheet are subject to irmsola L7 80% 'Fir ah-as la change without notice: . Smar_E,orgy rooether Smart Energy q Years 5 10 15 20 25 MPtOW >rina zrz.dslel ®. m_su e r cars O Solar SolarEdge Power Optimizer Ll�J Module Add-On for North America Ll ;! P300 / P350 / P400 SolarEdge Power Optimizer __ __. _ -- - - - �_-P300 t '350 P400 Module Add-On For North America (for 60-cell PV I for -c. .1 PV (for 96 cell PV modules) 11_ modules) L modules) Cpl.... INPUT P300 / P350 / P400 +..._.+ ___.. ` Rated.... DC Powers 300 350 400 W „ • Absolute Maximum Input Voltage(Voc at lowest temperature) 48 .. 80 I Vdc .... . .... ... ... ... ..... .... ... ...... ....... .. ,: - - MPPT Operating Range ._.,,,_..8..48 8 60, ...., ....8.-.80 Vdc_.., Maximum Short Grant Current(Isc) 10 1 Maximum Efficiency. ........ .... .. .. 99.5 ........ .... .. .. Weighted Efficiency Cu .. .. .. ... .. .. ... 98.8.. .. .... .A%c Maximum DC Input rent L. 4 > ..; _ _ ......... ....... . ..Z .... . _..... ._ _ _ _... .. OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) z {C.7�J Output is Adc _ _ �_"Vdc i Maximum Current ' Maximum O tp t Voltage 60 OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer._ _.__ __.._,_—,_— �. _ _ — 1 _ ----_______.._.._.�.._Vdc_ ' \ EMAND _ FCC Part15 Class B IEC61000-6 2,JEC61000-6-3 �� Safety..AR .. .......... . _ .. ... ..-IEC62109 1(class II safety),UL1741 .. ... ..... D COMPLIANCE _ . .._ ..... ... ... .... ... .... _. .. _.... ROHS Yes __ a wia _ INSTALLATION SPECIFICATIONS .. ...... ... .. .. . -- Maximum Allowed System Voltage NS......... ............ ,,.,.__ .. 1000 - "• J , _ -F=.� .i ," Dimensions(W xLx H) ........ .............. .. ,,..,-,., 141_x 212 x40.5/S55x8.34x159,..,..__. ............. Weight(including cables) 50/2.1 Input Connector . MC4/Amphenol/.Tyco ... .. ... _ .. .. _._ .. ..... Out Wire Type/Connector -Double Insulated Amphenol Output Wire Length 0.95/30 j 12/39 ./ft a & , Operating Temperature Range 40 +85/40 +185 'C/'F (, -g s Protection Raring .. . ........ .. .. .... ...._. ,............. .... .. IP65/NEMA4.. __.,. _.. .... - n d sx oowr,afm�mod��—.1— .._.. ....... _. ..-. ....... .._.._- ... .._. w �. Relative Humidity 0 100 % fu i ? PV SYSTEM DESIGN USING A SOLAREDGE THREE PHASE THREE PHASE _ SINGLE PHASE INVERTER 20_8V 480V_ PV[lower optimization at#FIE'module-le Minimum s ring Length(Power Optimizers) B l0 18. it ... . .. ... UptO 25%more energy Maximum Str ng Length(Power Optimizers) ( 25 25 50 Ma imum Power per String 5250 6000 12750 W --Superior efficiency(94.5%) - ... ..... . _.. .... . ...... i.... .. .... .... .�. ... .. .. ... ..�..... .. j - - - - Parallel Strings of Different Lengths or Orientations Yes '+ — Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading ""' ....... "' I......... -- - - Flexible system design for maximum space utilization, — Fast installation with a single.holt i — Next generation maintenance with module-level monitoring - - Module-level voltage shutdown for installer and firefighter safety USA - GERMAN( - rrAI.Y - FRANCE - IAPAN - CHINA ISRAEL - AUSTRALIA www.Sola redge.us Wuc Ft , d1SAPnLtA'�S taT�x"- " �+6v..5���#t�„z ':x ����a a�tuA•a4au5.uf� 4z�zcrraa�.,>ti,� � �+ue x ui++x .r4Z •�. . "tSOlar,City/ I ZepSolar Next-Level PV Mounting Technology ''i<SOlarCity Zep Solar Next-Level PV Mounting Technology Zep System Components for composition shingle roofs x Leveling Foot mcc,tocx � - " Ground Zep r.Wrric.M n Part No.850-1172 ~. • - — ETL listed to UL 467 r Zep Compatible PV Modute t 4411 ' x� Zep Oroovc •'. ' - .... ,.,,.:_•:� Rao[Atiachment _ �: An"ShirrComp Mount y Part No.850-1382 Listed to UL 2582 i Mounting Block Listed to UL 2703 I �Q �,OMPATj e�,� Description - ti • �� PV mounting solution for composition shingle roofs ~F /0 Works with all Zep Compatible Modules A - .MMPPt�v Auto bonding UL-listed hardware creates structural and electrical bond • Zep System has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2" Interlock Ground Zep V2 DC Wire Clip UL LISTED Specifications Part No.850-1388 Part No.850-1511 Part No.850-1448 Listed to UL 2703 Listed to UL 467 and UL 2703 Listed to UL 1565 • Designed for pitched roofs - Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and UL 467 • Zep System bonding products are UL listed to UL 2703 Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain Array Skirt,Grip, End Caps Part Nos.850-0113,850-1421, 850-1460,850-1467 zepsolar.com zepsolar.com Listed to UL 1565 This document does not create any express warranty by Zap Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM •o - : Label Location: Label Location: Label Location: (C)(CB) (� (AC)(POI) ® (DC) (INV) Per Code: Per Code: Per Code: NEC 690.31.G.3 °o No . NEC 690.17.E �'�. � NEC 690.35(F) Label Location: °C�'J ' ° - 0 0 0 TO BE USED WHEN ONE ° °-° ,° INVERTER IS (DC) (INV) UNGROUNDED D p - Per Code: NEC 690.14.C.2 Label Location: Label Location: qr- ° ° ° o' er (POI) DESHKIM -o - (DC) (INV) Per Code: 909M I-° Per Code: D o WO NEC 690.17.4; NEC 690.54 •o o -° NEC 690.53 T."y-yj D �ojyD D O` - D O O = Label Location: ♦ o (DC) (INV) r Per Code: NEC 690.5(C) 0. -o D D Label Location: o Do- (POI) Per Code: NEC 690.64.B.4 TLabel Location: " (DC) (CB) Per Code: s Label Location: - o ° NEC 690.17(4) © e (D) (POI) [ vim D* o - Per Coder o 0 0 .. ° NEC 690.64.B.4 D ° 0 oD = Label Location: A o (POI) Per Code: Label Location: ° NEC 690.64.B.7 (AC)(POI) D 4� o ' (AC): AC Disconnect © Per Code: D " - (C): Conduit �� NEC 690.14.C.2 (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit Label Location: (INV): Inverter With Integrated DC Disconnect (AC) (POI) (LC): Load Center ° ►� G Per Code: (M): Utility Meter Ur NEC 690.54 (POI): Point of Interconnection CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR �%lr pp 3055 Clearview way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED San Mateo,CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, psi►` T:(650)638-1028 F:(650)638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE Label Set �� SolarCit (888)-SOL-CITY(765-2489)www.solarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. ° 41 CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 874 Salem St ` AC DISCONNECT rJ 1 I 1 I I L� I L-- -J UTILITY INVERTER AND SERVICE DC DISCONNECT --------------- -------- SOLAR PHOTOVOLTAIC——— ARRAY(§) -I L--------------------------J PHOTOVOLTAIC BACK-FED 6RCWT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V JB-0183598-00 JB-0183598 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: Tom NIX \`�•�OI���'�� CONTAINED SHALL NOT BE USED FOR THE JOHN CONIDES John Confides RESIDENCE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: A.,� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 874 SALEM ST 6.63 KW PV ARRAY ►il PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES: NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH ' 24 St. Martin Drive, Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (26) TRINA SOLAR # TSM-255PDO5.18 PAGE NAME SHEET: REV DATE: Marlborough, MA 01752 SOLARCnY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T. (650) 638-1028 F: (650) 638-1029 PERMISSION of SOLMCITY INC. SOLAREDGE SE6000A—USOOOSNR2 6176992091 SITE PLAN PLACARD PV 6 3/23/2016 (BBB)-SOL-CITY(765-2489) www.solaraity.aom GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO TWO (N) GROUND Panel Number: NoMatch Inv 1: DC Ungrounded INV 1 —(1)SOLAREDGE #SE6000A—USO00SNR2 LABEL: A —(26)TRINA SOLAR # TSM-255PDO5.18 GEN #168572 ODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:98 648 073 Inverter; 60 OW, 240V, 97.5%; w/United Disco and ZB,RGM,AFCI PV Module; 255W, 232.2W PTC, 40MM, Black Frame, H4, ZEP, 1000V ELEC 1136 MR Underground Service Entrance INV 2 Voc: 38.1 Vpmax: 30.5 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER �E 150A MAIN SERVICE PANEL E� 10OA/2P MAIN CIRCUIT BREAKER Inverter 1 (E) WIRING CUTLER—HAMMER +DC+10OA/2P Disconnect 3 SOLAREDGE SE6000A—USOOOSNR2 —————MP 2 1x12 (E) LOADS A 1.1 2a.v -------- --------- —————� ~— N DC- 1 2 _ 35A/2P — _ EG2 Dc+ + JA ---- OND --——————————————— GEC ---lN DG G MP 1: 1x14 1 1 ——————————--- G --------------- —————————————————tJ I I N I (1)Conduit Kit; 3/4' EMT _J c EGC GEC 1 I 1 1 1 1 GEC TO 120/240V 1 i SINGLE PHASE I 1 1 1 UTILITY SERVICE 1 I 1 1 1 1 1 1 1 I 1 PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Voc* = MAX VOC AT MIN TEMP POI (1)CUTLER—HAMM�R #BR235 PV BACKFEED BREAKER A (1)CUTLER—HAMMER #DG222URB /� PV (26)SOLAREDGE BP300-2NA4AZS D� Breaker, 35A 2P, 2 Spaces Disconnect; 60A, 24OVac, Non—Fusible, NEMA 3R /y PowerBox Optimizer, 30OW, H4, DC to DC, ZEP —(2"578"X'08! Gro qd Rod —(11)CUTLERAMMER #DG10ON6 578 x 8, Copper Ground�Neutral Kit; 60-100A, General Duty(DG) nd (1)AwG #6, Solid Bare Copper —(1)Ground Rod; 5/8' x 8', Copper (N) ARRAY GROUND.PER 690.47(D). NOTE: PER EXCEPTION NO. 2, ADDITIONAL ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE 1 AWG EJB, THWN-2, Black 2)AWG X10, PV Wire, 600V, Black Voc* =500 VDC Isc =15 ADC (1)AWG#8, THWN-2, Red O (1)AWG #6, Solid Bare Copper EGC Vmp =350 VDC Imp=8.63 ADC LLLLLLLL 1 AWG 0, THWN-2, White NEUTRAL Vmp =240 VAC Im —25 AAC (I)Conduit Kit; 3/4'.EMT 70)AWP #8,,THWN72,Green . , EGC/GEC.-(1)Conduit.Kit;.3/4".EMT. ( (2)AWG X10, PV Wire, 600V, Black Voc* =500 VDC Isc =15 ADC CO rT ( ) #6, Solid Bare Copper EGC Vmp =350 VDC Imp=10.07 ADC 1 Conduit Kit; 3/4".EMT CON JB-0183598 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIALTHE INFORMATION HEREIN JOB NUMBER:— SolarCity.CONTAINED SHALL NOT BE USED FOR THE JOHN CONIDES John Conides RESIDENCE Tom Nix /BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 874 SALEM ST 6.63 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES- NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH r 24 St. Martin Drive,Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE 1 (26) TRINA SOLAR # TSM-255PDO5.18 SHEET: REV: DATE Marlborough, MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME T: (650) 638-1028 F: (650)638-1029 PERMISSION OF SOLARCITY INC. INVERTER: THREE LINE DIAGRAM / / SOLAREDGE SE6000A—USOOOSNR2 6176992091 PV 3 23 2016 (BBB)-soL-CITY(765-2489) www.solarcitycom S1 S 1 4" 9'—g„ 1'— (E) LBW 4 13'-9" 1'— (E) LBW B SIDE VIEW OF MP2 NTS SIDE VIEW OF MP1 NTS A MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES MPI X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER I NOTES LANDSCAPE 64" 24" STAGGERED LANDSCAPE 64" 24" STAGGERED PORTRAIT 48" 1$" PORTRAIT 48" 19" RAFTER 2x6 @ 16" OC ROOF AZI 282 PITCH 32 STORIES: 1 RAFTER 2X8 @ 16"OC ROOF AZI 209 PITCH 38 STORIES: 2 ARRAY AZI 282 PITCH 32 ARRAY AZI 209 PITCH 38 C.]. 2x4 @24�� OC Comp Shingle C.I. 2x8 @16"OC I Comp Shingle PV MODULE 5/16" BOLT WITH r INSTALLATION ORDER ' FENDER WASHERS LOCATE RAFTER, MARK HOLE ` cyG A�, LAR130 E. � i ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT D VESA ZEP ARRAY SKIRT (6) HOLE. STRUCTURAL SEAL PILOT HOLE WITH No. 5, 2160 (4) (2) POLYURETHANE SEALANT. `� ZEP COMP MOUNT CNALNb ZEP FLASHING C (3) (3) INSERT FLASHING.--] Digital y Abe De Vera Date:2016.03.23 14:16:26 (E) COMP. SHINGLE (4) PLACE MOUNT. -07'00' (1) (E) ROOF DECKING U (2) INSTALL LAG BOLT WITH 5/16" DIA STAINLESS (5) (5) SEALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES FINSTALL LEVELING FOOT WITH WITH SEALING WASHER (6) BOLT & WASHERS. (2-1/2" EMBED, MIN) (E) RAFTER STANDOFF Si Scale: 1 1/2" = 1' CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE JB-0183598 00 ���� i JOHN CONIDES John Confides RESIDENCE Tom Nix �;;SO�a�Cty BENEFIT OF ANYONE EXCEPT SOLARCIIY INC., MOUNTING SYSTEM: �••,c NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 874 SALEM ST 6.63 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES- NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St. Martin Drive, Building Z Unit 11 THE SALE AND USE OF THE RESPECTIVE (26) TRINA SOLAR # TSM-255PDO5.18 PAGE NAME SHEET: REN DATE Marlborough, MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T: (650)638-1028 F: (617 638-1029 PERMISSION of sotARCITY INC. SOLAREDGE SE6000A—USOOOSNR2 6176992091 STRUCTURAL VIEWS PV 3 3/23/2016 (888)-SOL-CITY(765-2489) www.solarcity.com PITCH: 38 ARRAY PITCH:38 MP1 AZIMUTH:209 ARRAY AZIMUTH: 209 MATERIAL: Comp Shingle STORY: 2 Stories PITCH: 32 ARRAY PITCH:32 MP2 AZIMUTH:282 ARRAY AZIMUTH: 282 MATERIAL: Comp Shingle STORY: 1 Story MPl Inv AC ® - I LEGEND A Front Of House c Q (E) UTILITY METER & WARNING LABEL 'ss INVERTER W/ INTEGRATED DC DISCO B b �` * q�y� Inv & WARNING LABELS o A - �- a� \ DC DISCONNECT & WARNING LABELS No. 52166 b �� � AC DISCONNECT & WARNING LABELS S��tsTaat G5 DC JUNCTION/COMBINER BOX & LABELS Digitally signed by Abe De Vera iEIDRrVEWAY Date:2016.03.2314:15:54-07'00' O DISTRIBUTION PANEL & LABELS STAMPED SIGNED Lc LOAD CENTER & WARNING LABELS E STRUCTURAL ONLY O DEDICATED PV SYSTEM METER j STANDOFF LOCATIONS - CONDUIT RUN ON EXTERIOR -- CONDUIT RUN ON INTERIOR GATE/FENCE Q HEAT PRODUCING VENTS ARE RED 874 Salem St L- "J INTERIOR EQUIPMENT IS DASHED SITE PLAN Scale:1/16" = 1' 01' 16' 32' xvIk ho wwwo S CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: JB-01 83598 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE JOHN CONIDES John Confides RESIDENCE ^,Tom Nix BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 874 SALEM ST 6.63 KW PV ARRAY VSolarCity. PART TO OTHERS OUTSIDE THE RECIPIENTSMoouLEs NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St. Martin Drive, Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (26) TRINA SOLAR # TSM-255PDO5.18 PAGE NAME: SHEET: REV. DATE: Marlborough, MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T. (650)638-1028 F: (650) 638-1029 PERMISSION OF SOLARCTY INC. SOLAREDGE SE6000A—USOOOSNR2 6176992091 SITE PLAN PV 2 3/23/2016 (BBB)-SOL-CITY(765-2489) www.solarcity.com f ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5: I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 SITE PLAN h" PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS I' LICENSE GENERAL NOTES PV5 THREE LINE DIAGRAM Cutsheets Attached I GEN #168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION ELEC 1136 MR OF THE MA STATE BUILDING CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. Mliyl 'l MODULE GROUNDING METHOD: ZEP SOLAR AHJ: North Andover REV BY DATE COMMENTS REV A NAME DATE COMMENTS UTILITY: National Grid USA (Massachusetts Electric) * * * * CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: JB 00 PREMISE OWNER: DESCRIPTION: DESIGN: ��\ CONTAINED SHALL NOT BE USED FOR THE JOHN CONIDES John Conides RESIDENCE Tom NIX BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: S NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type c 874 SALEM ST 6.63 KW PV ARRAY ►� oar y PART OTHERS OUTSIDE THE RECIPIENTS MODULES: NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH , THE SALE AND USE OF THE RESPECTIVE (26) TRINA SOLAR # TSM-255PDO5.18 24 St. Martin Drive, Building 2, Unit 11 EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: Marlborough, MA 01752 SOLARCITY EQUIP PERMISSION OF SOLARCITY INC. INVERTER: T: (650)638-1026 F: (650)636-1029 SOLAREDGE SE6000A—USOOOSNR2 6176992091 COVER SHEET PV 1 3/23/2016 (866)-SOL-CITY(765-2489) www.solarcitycom