Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Building Permit #586-2016 - 98 LYMAN ROAD 11/12/2015
��Rnrs l�o� Sc>aNnVIED BUILDING PERMIT of N°DTH qti qt 6g � TOWN OF NORTH ANDOVER APPLICATION FOR PLAN EXAMINATION h �O/ Date Received Permit No#: S 6 �7Eo s SqS CHU Date Issued: 171 IMPORTANT: Applicant must complete all items on this page LOCATION Print�T PROPERTY OWNER. nn 1 .0 Year Structure yes o MAP PARCEL-. _ ZONING DISTRICT Historic District yes �no Machine Shop Village yes no TYPE OF IMPROVEMENT PROPOSED USE Residential Non- Residential New Building ❑ One family ❑Addition ❑ Two or more family ❑ Industrial ❑Alteration No. of units: ❑ Commercial ❑ Repair, replacement ❑Assessory Bldg ❑ Others: ❑ Demolition ❑ Other ❑ Septic ❑Well ❑ Floodplain. 0 Wetlands 0. Watershed District ❑Water/Sewer DESCRIPTION OF WORK TO BE PERFORMED: Id ratification- Please Type or Print Clearly OWNER: Name: r Phone: l01 QJ �� �� Address: I A L. ry)m Contractor Name: _-__ Phone: ___ . Email: Address: Supervisor's Construction License: Exp. Date: Horne Improvement License:_._ _,____ _ uvExp. Date. : -_ ARCHITECT/ENGINEER Phone: Address: Reg. No. FEE SCHEDULE:BULDING PERMIT:$12.00 PER$1000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PER S.F. Total Project Cost: $ �..� Q, 0 0 - FEE: $ , S-9 6 Check No.: Receipt No.: `i-cl 4LI NOTE: Persons contractin mith un ' tered contractors not have access to the guaranty fund 5ignafure of A.ent/O nerto _ nature of contractor _ - Building Department The following is a list of the required forms to be filled out for the appropriate permit to be obtained. Roofing, Siding, Interior Rehabilitation Permits o Building Permit Application o Workers Comp Affidavit o Photo Copy Of H.I.C. And/Or C.S.L. Licenses a Copy of Contract o Floor Plan Or Proposed Interior Work o Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit Addition Or Decks Li Building Permit Application o Certified Surveyed Plot Plan L3 Workers Comp Affidavit o Photo Copy of H.I.C. And C.S.L. Licenses o Copy Of Contract ❑ Floor/Cross Section/Elevation Plan Of Proposed Work With Sprinkler Plan And Hydraulic Calculations (If Applicable) o Mass check Energy Compliance Report (If Applicable) o Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit New Construction (Single and Two Family) o Building Permit Application o Certified Proposed Plot Plan o Photo of H.I.C. And C.S.L. Licenses o Workers Comp Affidavit Li Two Sets of Building Plans (One To Be Returned) to Include Sprinkler Plan And Hydraulic Calculations (If Applicable) o Copy of Contract a Mass check Energy Compliance Report o Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg. Permit i In all cases if a variance or special permit was required the Town Clerks office must stamp the decision from the Board of Appeals that the appeal period is over. The applicant must then get this recorded at the Registry of Deeds. One copy and proof of recording must be submitted with the building application Doc:Building Permit Revised 2014 Plans Submitted ❑ Plans Waived ❑ Certified Plot Plan ❑ Stamped Plans ❑ TYPE OF SEWERAGE DISPOSAL Public Sewer & Taming/Massage/Body Art ❑ Swimming Pools ❑ Well ❑ Tobacco Sales ❑ Food Packaging/Sales ❑ Private(septic tank,etc. ❑ Permanent Dumpster on Site ❑ I THE FOLLOWING SECTIONS FOR OFFICE USE ONLY INTERDEPARTMENTAL SIGN OFF - U FORM PLANNING & DEVEL PMENT Reviewed On Signature_ COMMENTS CONSERVATION Reviewed onSi nature' COMMENTS / HEALTH Reviewed on Sig nature IG COMMENTS _______4)t Zoning Board of Appeals: Variance, Petition No: Zoning Decision/receipt submitted yes Planning Board Decision: Comments Conservation Decision: Comments 4 , D �*er & Sewer Connection/si nature& a � � _1Z� 1 y nvewa Permit DPW Town Engineer: Signature:ZEE: iii: f/ E DEPARfiTMENT - t em� ® nes T — 3n T p est ,rso - e iter � — Located Os oo ree (Located at 124'1l\Q treet S Fire Department ignature/dates - � GOMMENTS; f Dimension Number of Stories: Total square feet of floor area, based on Exterior dimensions. Total land area, sq. ft.: ELECTRICAL: Movement of Meter location, mast or service drop requires approval of Electrical Inspector Yes No DANGER ZONE LITERATURE: Yes No MGL Chapter 166 Section 21A—F and G min.$100-$1000 fine NOTES and DATA— (For department use) Notified for pickup Call Email Date Time Contact Name Doe.Building Permit Revised 2014 koRT11 CERTIFICATE OF USE & OCCUPANCY TOWN OF NORTH ANDOVER Permit# 586 (9/26/2016) Date: October 27, 2016 THIS CERTIFIES THAT THE BUILDING LOCATED ON 98 Lyman Road MAY BE OCCUPIED AS Single Family Home ACCORDANCE WITH THE PROVISIONS OF THE MASSACHUSETTS STATE BUILDING CODE AND SUCH OTHER REGULATIONS AS MAY APPLY. Certificate Issued to: Nidia Peguero 98 Lyman Road North A over MA 01845 Building Inspector NORT#1 Of,taD�a11' CERTIFICATE OF USE & OCCUPANCY 7 +DRATaD CHUTOWN OF NORTH ANDOVER Permit# 586 (9/26/2016) Date: October 27, 2016 THIS CERTIFIES THAT THE BUILDING LOCATED ON 98 Lyman Road MAY BE OCCUPIED AS Single Family Home ACCORDANCE WITH THE PROVISIONS OF THE MASSACHUSETTS STATE BUILDING CODE AND SUCH OTHER REGULATIONS AS MAY APPLY. Certificate Issued to: Nidia Peguero 98 Lyman Road North A over MA 0l 845 Building Inspector 0 APPLICATION FOR CERTIFICATE OF OCCUPANCYANSPECTION BUILDING PERMIT #,06 SSACHU`��� ADDRESS/LOCATION OF PROPERTY: �� L vmcLo et�d Map Parcel Lot Number SUBDIVISION: DATE REQUESTED FILED/READY FOR INSPECTION: CLOSING DATE ON PROPERTY: FIVE (5) DAYS NOTICE PRIOR TO CLOSING DATE IS REQUIRED' ALL WORK AND SIGN-OFFS MUST BE COMPLETED WITHIN THIS TIME FRAME. A REINSPECTION FEE OF TWENTY DOLLARS ($20 ,0) WILL BE GED IF THE STRUCTURE DOES NOT MEET ALL APPLICABLE CODE GN APPLICANT SIATURE Permit Issued to: klea Address: L W(ra n c c�CI ROUTING CONSERVATION L1 PLANNING �rpi1�t DPW-WATER METER SEWER CONNECTION Dd DPW MUST INDICATE THAT THE WATER METER HAS BEEN INSTALLED PRIOR TO SUBMITTAL OF THE.000UPANCY/INSPECTION REQUEST SIGNATURE File:Application for OC form revised Jan 2007 r 1 �ORTH - ver No. %k 2V ver, Mass, Q} LAµ. Y coc Hlc NEw.t. ry. A�RATEO � U BOARD OF HEALTH Food/Kitchen PERMIT T LD Septic System THIS CERTIFIES THAT ................ <<:...:. .............. :.`.`. . .................................................................. BUILDING INSPECTOR `.i • Foundation has permission to erect . • ........... buildings on .....: .w�.. S..l ..:� i�4 a1......?• ................................ / � •Rough to be occupied as .............. .! :.. :.. ,.. s�.':.::.:: .:.............:.::`: :.:: ... .,.:...: .:. ................................. 71 U6 •+• •'• Chimney ,7 provided that the person accepting this permit shall in every respect conform to the terms of the application FinalF'�Na�� �' n•�7�,��i on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection, Alteration and Construction of Buildings in the Town of North Andover. P UMBING INSPECTOR Rough VIOLATION of the Zoning or Building Regulations Voids this Permit. � Final aGI PERMIT EXPIRES IN 6 MONTHSICAL S CTOR UNLESS CONSTRUCTION/STARTS Rough DIONService ...,....,-.........%.... ;.....,�. ,:.::5-�:................................... Fin u ` BUILDING INSPECTOR GAS INSPECTOR Occupancy Permit Required to Occupy Building Roug Ql Display p in a Conspicuous Place on the Premises — Do Not Remove Final n �� No Lathing or Dry Wall To Be Done FIRE DEPARTM Until Inspected and Approved by the Building Inspector. Burner Street No. �j�- Smoke Det./ 07116 1 t �a. F_ '1 0 MI: R'THpAuc . )ve" _ No. N %kt , `4t �. h ,,, ver, Mass, f7 <ANe - COCNICHlW1CK A0RRreD OP0V� S S U BOARD OF HEALTH Food/Kitchen PERMIT T LD Septic System THIS CERTIFIES THAT ................ .......... ` :. .. .::. .................................................................. BUILDING INSPECTOR has permission to erect .............. buildings on �4w:�<...:. Foundation p ............ .... ..... .. ................................ ton f . , Rough to be occupied as .............. ... .::. . ..`............. .: ... .... ...:. ' ... '................................... .�. ��` .: .rs < s.�.: Jam° c 'OL ' Chimney c provided that the person accepting this permit shall in every respect conform to the terms of the application Final on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection, Alteration and 6L- FOVA& fn.t?- Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR Rough { VIOLATION of the Zoning or Building Regulations Voids this Permit. Final rGI PERMIT EXPIRES IN 6 MONTHSICAL�VS CTOR UNLESS CONSTRUCTIOWSTARTS Rough Service / <— ...... ........ .�. L`: ..v �... ................................... Fin u BUILDING INSPECTOR GAS INSPECTOR Occupancy Permit Required to Occupy Buildinm Roug Display in a Conspicuous Place on the Premises — Do Not Remove Finalrz No Lathing or Dry Wall To Be Done FIRE DEPARTM Until Inspected and Approved by the Building Inspector. Burner Street No. Smoke Det 0 �7 1� 4 C4, Home Energy Rating Certificate Property HERS Nidia Peguero Rating Type: Confirmed Certified Energy Rater: Roy Chatalbash 98 Lyman Rd Rating Date: 10/14/16 Rating Number: SEA3672C North Andover,MA 01845 Registry ID: 110820526 Estimated Annual Energy Cost HERS Index: 64 Efficient Home Comparison: 36%Better Use MMBtu Cost Percent Heating 47.1 $1515 49% General information Cooling 8.2 $161 5% Conditioned Area 2396 sq.ft. House Type Single-family detached Hot Water 4.0 $257 8% Conditioned Volume 23512 cubic ft. Foundation More than one type Lights/Appliances 22.5 $1186 38% Bedrooms 4 Photovoltaics -0.0 $-0 -0% Service Charges $0 0% Mechanical Systems Features Total 81.8 $3119 100% Heating: Fuel-fired air distribution,Natural gas,92.0 AFUE. Heating: Fuel-fired air distribution,Natural gas,92.0 AFUE. Criteria Cooling: Air conditioner,Electric,13.0 SEER. This home meets or exceeds the minimum criteria for the following: Duct Leakage to Outside 127.00 CFM25. Massachusetts Residential New Construction Program* Ventilation System None Massachusetts Stretch Energy Code' Programmable Thermostat Heat=Yes;Cool=Yes 'Compliance is determined by the rater. Building Shell Features Ceiling Flat R-38.0 Slab None Sealed Attic NA Exposed Floor R-30.0 Vaulted Ceiling R-38.0 Window Type U-Value:0.300,SHGC:0.290 Above Grade Walls R-21.0 Infiltration Rate Htg:1954 Clg:1954 CFM50 Foundation Walls R-0.0 Method Blower door test Rating Team Sustainable Energy Analytics Lights and Appliance Features 4 Militia Drive,Suite 6 Percent Interior Lighting 90.00 Range/Oven Fuel Natural gas Lexington,MA.02421 Percent Exterior Lighting 100.00 Clothes Dryer Fuel Electric 781-652-8282 Refrigerator(kWh/yr) 691 Clothes Dryer EF 3.01 Energystar@sea.us.com Dishwasher Energy Factor 0.46 Ceiling Fan(cfm/Watt) 0.00 Certified Energy Rater: REM/Rate-Residential Energy Analysis and Rating Software v14.6.4 This information does not constitute any warranty of energy cost or savings.©1985-2016 Noresco,Boulder,Colorado. The Home Energy Rating Standard Disclosure for this home is available from the rating provider. RESNET Home Energy Baling a standard Disclosure For home located at: 98 Lyman Rd City: North Andover State: MA 1. PX The Rater or Rater's employer is receiving a fee for providing the rating on this home. 2. ❑ In addition to the rating, the Rater or Rater's employer has also provided the following consulting services for this home. A. Mechanical system design B. Moisture control or indoor air quality consulting C. Performance testing and/or commissioning other than required for the rating itself D. Training for sales or construction personnel E. Other(specify below) 3. The Rater or Rater's employer is: A. The seller of this home or their agent B. The mortgagor for some portion of the financial payments on this home C. An employee, contractor or consultant of the electric and/or natural gas utility serving this home 4. The Rater or Rater's employer is a supplier or installer of products, which may include: Installed in this home by: OR is in the business of: HVAC Systems Rater Employer Rater Employer Thermal Insulation Systems Rater Employer Rater Employer Air sealing of envelope or duct systems Rater Employer Rater Employer Windows or window shading systems Rater Employer Rater Employer Energy efficient appliances Rater Employer Rater Employer Construction (builder, developer, construction contractor, etc.) Rater Employer Rater Employer Other(specify below): Rater Employer Rater Employer I attest that the above information is true and correct to the best of my knowledge. As a Rater or Rating Provider I abide by the rating quality control provisions of the Mortgage Industry National Home Energy Rating Standard as set forth by the Residential Energy Services Network(RESNET).The national rating quality control provisions of the rating standard are contained in Chapter One 4.C.8. of the standard and are posted at http://resnet.us/standards/RESNET_Mortgage_Industry_National_HERS_Standards.pdf. The Home Energy Rating Standard Disclosure for this home is available from the rating provider. Roy Chatalbash 7482231 Rater's rdlame Certification# October 18, 2016 `Ra er's Signa I ure f Date RESNET Form 0300-2 REM/Rate- Residential Energy Analysis and Rating Software v14.6.4 This information does not constitute any warranty of energy cost or savings. 0 1985-2016 Noresco, Boulder, Colorado. tkORTH TOWN OF NORTH ANDOVER OFFICE OF . BUILDING DEPARTMENT 'a1600 Osgood Street,Building 20, Suite 2035 North Andover,Massachusetts 01845 1SgACH�SE� Gerald A.Brown Telephone(978)688-9545 Inspector of Buildings Fax (978)688-9542 HOMEOWNER LICENSE EXEMPTION BUIDING PERMIT APPLICATION Please print DATE: JOB LOCATION: I L,Ymn Number S eet Address Map/Lot r c 9%21- r7 0L4_ (0 ()S'$ HOMEOWNER L Name Home Phone Work Phone PRESENT MAILING ADDRESS City Town State Zip Code The current exemption for"homeowners"was extended to include owner occupied dwellings of one or two family dwellings and to allow such homeowners to engage an individual for hire who does not possess a license, rop vided that the owner acts as supervisor. DEFINITION OF HOMEOWNER Person(s)who owns a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one-or two-family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. (780 CMR Section 110.R5.1.2) The undersigned"homeowner"assumes responsibility for-compliance with State Building Code and other applicable codes,by-laws,rules and regulations. The undersigned"homeowner"certifies that e understands the Town of North Andover Building Department minimum inspection procedures and requ' ents and that he/she w' c ply with said procedures and requirements. HOMEOWNERS SIGNATURE At APPROVAL OF BUILDING OFFICIAL Revised 8.2015 Form Homeowners Exemption BOARD OF APPEALS 688-9541 CONSERVATION 688-9530 HEALTH 688-9540 PLANNING 688-9535 Enter construction cost for fee cal - North Andover Fee Calculation Construction Cost $) 2850010-00 m $ - $ 3,420.00 Plumbing Fee $ 427.50 Gas Fee 100 comm. $a 11001.00 Electrical Fee $ 427.50 Total fees collected $ 4,375.00 98 Lyman Road 586-2016 on 11/12/2015 Reconstruction of Home r 1 tkORTH c . : ver 0 : . T •j• b ,� oh ver, Mass, 1AZ 1,12d COCNIC.1WICK y1' X1,95 R�reo �Pa,�gS U BOARD OF HEALTH Food/Kitchen PERMIT T LD Septic System THIS CERTIFIES THAT ........... C ................................................................. BUILDING INSPECTOR z has permission to erect .......................... buildings on ..... /. �yi... <.Y... .. ................................... Foundation Rough to be occupied as ............... ... 1........ � vrr. t�`..r. ! .... ................................... Chimney provided that the person accepting this permit shall in every respect conform to the terms of the application Final on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection, Alteration and Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR VIOLATION of the Zoning or Building Regulations Voids this Permit. Rough Final PERMIT EXPIRES IN 6 MONTHS ELECTRICAL INSPECTOR UNLESS CONSTRUCTI TART_ S Rough Service ........ ...... ... . .. ..................................... Final BUILDING INSPECTOR - GAS INSPECTOR Occupancy Permit Required to Occupy Buildinz Rough Display in a Conspicuous Place on the Premises — Do Not Remove Final No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. Burner Street No. Smoke Det. e t - CREScheck Software Version 4.6.2 NJ/ Compliance Certificate Project Peguero Residence ADDITION Energy Code: 2012 IECC Location: North Andover, Massachusetts Construction Type: Single-family Project Type: Addition Climate Zone: 5 (6322 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 98 Lyman Road Luis& Nidia Peguero North Andover, MA 01845 98 KLyman Road Hankey Designs North Andover, MA 01845 P.O. Box 93 781.704.6758 N.Salem, NH 033073 n.peguero@comcast.net 603.490.0258 . trade-off Compliance: 0.0%.Better Than Code Maximum UA: 68 Your UA: 68 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly or U-Factor UA Ceilings Second Floor: Cathedral Ceiling 175 49.0 0.0 0.022 4 Front Walls First Floor:Wood Frame, 16" o.c. 100 21.0 0.0 0.057 5 Door: Glass 20 0.320 6 Left Walls First Floor:Wood Frame, 16"o.c. 180 21.0 0.0 0.057 9 Windows:Vinyl/Fiberglass Frame:Double Pane with Low-E 7 0.320 2 Door: Solid 18 0.400 7 Back Walls First Floor:Wood Frame, 16"o.c. 100 21.0 0.0 0.057 4 Windows:Vinyl/Fiberglass Frame:Double Pane with Low-E 7 0.320 2 Door: Glass 18 0.320 6 Front Walls Second Floor: Wood Frame, 16" D.C. 76 21.0 0.0 0.057 4 Windows:Vinyl/Fiberglass Frame:Double Pane with Low-E 7 0.320 2 Left Walls Second Floor:Wood Frame, 16"o.c. 126 21.0 0.0 0.057 7 Back Walls Second Floor:Wood Frame, 16" o.c. 68 21.0 0.0 0.057 4 Floor First Floor:All-Wood joist[Truss:Over Unconditioned Space 175 30.0 0.0 0.033 6 Project Title: Peguero Residence ADDITION Report date: 11/09/15 Data filename: C:\Users\Mike\Dropbox\Project Files\98 Lyman Rd ADDITION MA 11-9-15.rck Pagel of 9 + e + Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2012 IECC requirements in REScheck Version 4.6.2 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Mic a ,C GGi�(Ol? ��.A�rL 11-9-15 Name-Title Signature Date Project Title: Peguero Residence ADDITION Report date: 11/09/15 Data filename: C:\Users\Mike\Dropbox\Project Files\98 Lyman Rd ADDITION MA 11-9-15.rck Page 2 of 9 t l REScheck Software Version 4.6.2 Inspection Checklist Energy Code: 2012 IECC Requirements: 100.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions &Req.ID 103.1, ;Construction drawings and ❑Complies ;Requirement will be met. 103.2 :documentation demonstrate ❑Does Not [PRl]1 :energy code compliance for the :building envelope. ❑Not Observable ; ❑Not Applicable 103.1, ;Construction drawings and ❑Complies ;Requirement will be met. 103.2, ;documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR311 ;lighting and mechanical systems. ❑Not Observable ,U ;Systems serving multiple ❑Not Applicable :dwelling units must demonstrate ;compliance with the IECC ; !Commercial Provisions. ; 302.1, ,Heating and cooling equipment is{ Heating: Heating: ;❑Complies ;Requirement will be met. 403.6 !sized per ACCA Manual S based : Btu/hr Btu/hr I❑Does Not [PR2]2 ion loads calculated per ACCA Cooling: Cooling: ;❑Not Observable J `Manual j or other methods ; Btu/hr Btu/hr :❑Not Applicable I approved by the code official. Additional Comments/Assumptions: 1 JHigh Impact(Tier 1) 12 IMedium Impact(Tier 2) 13 Low Impact(Tier 3) Project Title: Peguero Residence ADDITION Report date: 11/09/15 Data filename: C:\Users\Mike\Dropbox\Project Files\98 Lyman Rd ADDITION MA 11-9-15.rck Page 3 of 9 , section # Foundation Inspection Complies? Comments/Assumptions & Req.ID 303.2.1 A protective covering is installed to ;❑Complies ;Requirement will be met. [FO11]2 :protect exposed exterior insulation :❑Does Not land extends a minimum of 6 in. below 'grade. :❑Not Observable; 1 ;❑Not Applicable 403.8 ;Snow-and ice-melting system controls;❑Complies ;Requirement will be met. [FO12]2 linstalled. ;❑Does Not A� ;❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 12 IMedium Impact(Tier 2) 13 ILow Impact(Tier 3) Project Title: Peguero Residence ADDITION Report date: 11/09/15 Data filename: C:\Users\Mike\Dropbox\Project Files\98 Lyman Rd ADDITION MA 11-9-15.rck Page 4 of 9 section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, ;Door U-factor. U- U- ;❑Complies ;See the Envelope Assemblies 402.3.4 CDoes Not table for values. [FR1]1 I 1❑Not Observable ❑Not Applicable 402.1.1, ;Glazing U-factor(area-weighted U- ; U- ;❑Complies ;See the Envelope Assemblies 402.3.1, average). QDoes Not ;table for values. 402.3.3, 1 402.3.6, ![-]Not Observable 402.5 ;❑Not Applicable [FR2]1 303.1.3 ;U-factors of fenestration products ❑Complies ;Requirement will be met. [FR4]1 :are determined in accordance ❑Does Not va ;with the NFRC test procedure or ❑Not Observable ;taken from the default table. ❑Not Applicable 402.4.1.1 ;Air barrier and thermal barrier ❑Complies ;Requirement will be met. [FR23]1 :installed per manufacturer's ❑Does Not instructions. ❑Not Observable ; ❑Not Applicable 402.4.3 ;Fenestration that is not site built ❑Complies ;Requirement will be met. [FR20]1 :is listed and labeled as meeting ❑Does Not 1AAMA/WDMA/CSA 101/I.S.2/A440 : :or Observable or has infiltration rates per NFRC 1400 that do not exceed code ❑Not Applicable ;limits. 402.4.4 IC-rated recessed lighting fixtures ❑Complies ;Requirement will be met. [FR16]2 sealed at housing/interior finish ❑Does Not sand labeled to indicate<_2.0 cfm ❑Not Observable leakage at 75 Pa. ❑Not Applicable 403.2.1 ;Supply ducts in attics are R- R- :[]Complies ;Requirement will be met. [FR12]1 :insulated to >_R-8.All other ductsI R R_ :❑Does Not lin unconditioned spaces or I ❑Not Observable ;outside the building envelope are ; ; insulated to >11-6. ;❑Not Applicable ; 403.2.2 ;All joints and seams of air ducts, ❑Complies !Requirement will be met. [FR13]1 lair handlers, and filter boxes are []Does Not sealed. []Not Observable ❑Not Applicable 403.2.3 IBuilding cavities are not used as ❑Complies ;Requirement will be met. [FR15]3 iducts or plenums. []Does Not ❑Not Observable ❑Not Applicable 403.3 ;HVAC piping conveying fluids R- R- ;❑Complies ;Requirement will be met. [FR17]2 labove 105 4F or chilled fluids 1 1 :❑Does Not below 55°F are insulated to >_R- 3. Q ; ; ;❑Not Observable j❑Not Applicable 403.3.1 ;Protection of insulation on HVAC ❑Complies ;Requirement will be met. [FR24]1 piping. ❑Does Not 1 ❑Not Observable ❑Not Applicable j 403.4.2 ;Hot water pipes are insulated to R- R- ;❑Complies ;Requirement will be met. [FR18]2 1>_R-3. :❑Does Not ❑Not Observable ❑Not Applicable 1 lHigh Impact(Tier 1) 12 IMedium Impact(Tier 2) 13 JLow Impact(Tier 3) Project Title: Peguero Residence ADDITION Report date: 11/09/15 Data filename: C:\Users\Mike\Dropbox\Project Files\98 Lyman Rd ADDITION MA 11-9-15.rck Page 5 of 9 section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 403.5Automatic or gravity dampers are ❑Complies ;Requirement will be met. [FR19]2 ,installed on all outdoor air ❑Does Not intakes and exhausts. []Not Observable I � ❑Not Applicable Additional Comments/Assumptions: 1 JHigh Impact(Tier 1) 12 IMedium Impact(Tier 2) 13 ILow Impact(Tier 3) Project Title: Peguero Residence ADDITION Report date: 11/09/15 Data filename: C:\Users\Mike\Dropbox\Project Files\98 Lyman Rd ADDITION MA 11-9-15.rck Page 6 of 9 Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions &Req.ID 303.1 ;All installed insulation is labeled ❑Complies ;Requirement will be met. [IN13]2 ;or the installed R-values []Does Not ,provided. ❑Not Observable ; ❑Not Applicable 402.1.1, ;Floor insulation R-value. R- R- ;❑Complies ;See the Envelope Assemblies 402.2.6 ;❑ Wood ;❑ Wood :❑Does Not table for values. [IN1]1 ❑ Steel ❑ Steel ;❑Not Observable ❑Not Applicable 303.2, ;Floor insulation installed per ❑Complies ;Requirement will be met. 402.2.7 :manufacturer's instructions, and ❑Does Not [IN2]1 :in substantial contact with the �i ;underside of the subfloor. []Not Observable ; ❑Not Applicable 402.1.1, ;Wall insulation R-value. If this is a; R- R- ;❑Complies ;See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the E] Wood ;r-1Wood ;❑Does Not table for values. 402.2.6 ;wall insulation on the wall I❑ Mass ❑ Mass ;❑Not Observable 1 [IN3]1 exterior,the exterior insulation ❑ Steel F] Steel ❑Not Applicable !requirement applies(FR10). 303.2 ;Wall insulation is installed per ❑Complies ;Requirement will be met. [IN4]1 manufacturer's instructions. ❑Does Not []Not Observable []Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 12 IMedium Impact(Tier 2) 13 Low Impact(Tier 3) Project Title: Peguero Residence ADDITION Report date: 11/09/15 Data filename: C:\Users\Mike\Dropbox\Project Files\98 Lyman Rd ADDITION MA 11-9-15.rck Page 7 of 9 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, ;Ceiling insulation R-value. ; R- ; R- ;❑Complies ;See the Envelope Assemblies 402.2.1, ;❑ Wood j❑ Wood ;❑Does Not table for values. 402.2.2, !❑ Steel ❑ Steel ;❑Not Observable 402.2.6 [Fill' ;❑Not Applicable 303.1.1.1, ;Ceiling insulation installed per ❑Complies ;Requirement will be met. 303.2 manufacturer's instructions. ❑Does Not [F1211 ;Blown insulation marked every ;300 ft2. ❑Not Observable ❑Not Applicable 402.2.3 ;Vented attics with air permeable ❑Complies ;Requirement will be met. [FI22]2 linsulation include baffle adjacent ❑Does Not :to soffit and eave vents that ;extends over insulation. ❑Not Observable ; I ❑Not Applicable 402.2.4 ;Attic access hatch and door ; R- ; R- ;,[]Complies ;Requirement will be met. [F1311 insulation >_R-value of the !❑Does Not adjacent assembly. :[]Not Observable ❑Not Applicable 402.4.1.2 ;Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = I❑Complies ;Requirement will be met. [FI17]1 Iach in Climate Zones 1-2,and I !❑Does Not I<=3 ach in Climate Zones 3-8. ;❑Not Observable ; ❑Not Applicable 403.2.2 ;Duct tightness test result of<=4 cfm/100 ; cfm/100 I❑Complies ;Requirement will be met. [FI411 :cfm/100 ft2 across the system or ft2 ft2 ❑Does Not to <=3 cfm/100 ft2 without air ;handler @ 25 Pa. For rough-in ,❑Not Observable ; tests, verification may need to ; ;❑Not Applicable ; ;occur during Framing Inspection. 403.2.2.1 ;Air handler leakage designated ❑Complies ;Requirement will be met. [FI24]1 :by manufacturer at<=2%of []Does Not design air flow. ❑Not Observable ; []Not Applicable 403.1.1 ;Programmable thermostats ❑Complies ;Requirement will be met. [FI9]2 installed on forced air furnaces. ❑Does Not ❑Not Observable I ❑Not Applicable 403.1.2 ;Heat pump thermostat installed ❑Complies ;Requirement will be met. [FI10]2 on heat pumps. ❑Does Not ❑Not Observable []Not Applicable 403.4.1 (Circulating service hot water ❑Complies ;Requirement will be met. [FI11]2 Isystems have automatic or ❑Does Not :accessible manual controls. ❑Not Observable []Not Applicable 403.5.1 !All mechanical ventilation system ❑Complies ;Requirement will be met. [FI25]2 ;fans not part of tested and listed ❑Does Not +HVAC equipment meet efficacy I air flow limits. ❑Not Observable ; ❑Not Applicable 404.1 ;75%of lamps in permanent ❑Complies ;Requirement will be met. [FI611 !fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. ;Does not apply to low-voltage ❑Not Observable , ❑Not Applicable lighting. , 1 JHigh Impact(Tier 1) 12 IMediurn Impact(Tier 2) 13 Low Impact(Tier 3) Project Title: Peguero Residence ADDITION Report date: 11/09/15 Data filename: C:\Users\Mike\Dropbox\Project Files\98 Lyman Rd ADDITION MA 11-9-15.rck Page 8 of 9 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions &Req.ID 404.1.1 ;Fuel gas lighting systems have ❑Complies ;Requirement will be met. [F[23]3 no continuous pilot light. ❑Does Not j ❑Not Observable ❑Not Applicable 401.3 iCompliance certificate posted. ❑Complies ;Requirement will be met. [FI7]2 ❑Does Not 4 I ❑Not Observable ❑Not Applicable 303.3 ,Manufacturer manuals for ❑Complies ;Requirement will be met. [FI18]3 (mechanical and water heating ❑Does Not ;systems have been provided. ij ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 JHigh Impact(Tier 1) 2 Medium Impact(Tier 2) 13 Low Impact(Tier 3) Project Title: Peguero Residence ADDITION Report date: 11/09/15 Data filename: C:\Users\Mike\Dropbox\Project Files\98 Lyman Rd ADDITION MA 11-9-15.rck Page 9 of 9 2012 IECC Energy Efficiency Certificate Insulation . Above-Grade Wall 21.00 Below-Grade Wall 0.00 Floor 30.00 Ceiling / Roof 49.00 Ductwork (unconditioned spaces): Glass& Door Rating U-Factor SHGC Window 0.32 Door 0.32 Cooling Heating System: Cooling System: Water Heater: Name: Date: Comments