Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Building Permit #076-2017 - Exception 7/25/2016
1. N0 RT H qti BUILDING PERMIT �? 4� ,. •6 °L oTOWN NORTH ANDOVER APPLICATION FOR PLAN EXAMINATION Permit NO: Date Received Arlo A Date Issued: �9SSACHUS IMPORTANT:Applicant must complete all items on this page LOCATION Multiple Utility Pole Attachments-See plans provided herein Print PROPERTY OWNER National Grid Print MAP NO: N/A PARCEL: N/A ZONING DISTRICT: N/A Historic District yes no N/A Machine Shop Village yes no TYPE OF IMPROVEMENT PROPOSED USE Residential Non- Residential ❑ New Building ❑ One family ❑Addition ❑Two or more family ❑ Industrial ❑Alteration No. of units: K Commercial ❑ Repair, replacement ❑Assessory Bldg K Others:Wireless telecommunic tion ❑ Demolition ❑ Other utility pole attachments ❑ Septic ❑Well ❑ Floodplain ❑Wetlands ❑ Watershed District ❑Water/Sewer See plans provided herein. Identification Please Type or Print Clearly) OWNER: Name: National Grid Phone: (781)907-3455 II Address: 40 Sylvan Road,Waltham, MA 02451 I CONTRACTOR Name: Phone: (207)642-5751 Kyle Purrington-Wireless Construction, Inc. Address: 40 Blake Road,Standish, ME 04084 Supervisor's Construction License: Exp. Date: CS-103000 09/14/2016 Home Improvement License: Exp. Date: N/A N/A ARCHITECT/ENGINEER Hudson Design Group, LLC Phone: (978)557-5553 Address: 1600 Osgood St., Building 20 North, Suite 3090, Reg. No. N.Andover, MA 01845 FEE SCHEDULE:BULDING PERMIT:$12.00 PER$1000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PER S.F. Total Project Cost: $ 210,000.00 FEE: $ 2,520.00 Check No.: �--d 413-1 y Receipt No.: S Oco 5 z- NOTE: Persons contracting with unre I tered contractors do not have access to the guaranty fund Signature of Agent/Owner Please a li nse attached Signature of contractor Please see attached. BUILDING PERMIT TOWN OF NORTH ANDOVER o �' APPLICATION FOR PLAN EXAMINATION _ ._ ._ pq cocweV..cM`�• Permit No#: Date Received SACHUS Date Issued: IMPORTANT:Applicant must complete all items on this page i LOCATION Print PROPERTY OWNER Print 100 Year Structure yes no MAP PARCEL: ZONING DISTRICT: Historic District yes no Machine Shop Village yes no TYPE OF IMPROVEMENT PROPOSED USE Residential Non- Residential ❑ New Building ❑ One family ❑ Addition ❑Two or more family ❑ Industrial ❑Alteration No. of units: ❑ Commercial ❑ Repair, replacement- 0 Assessory Bldg El Others: ❑ Demolition ❑ Other rI Flodp ainr'`'' ®Wetlan e s F® Wat�re homed t strict ® Sep ❑�111e l ❑ -`-�` DESCRIPTION OF WORK TO BE PERFORMED: Identification- Please Type or Print Clearly OWNER: Name: Phone: Address: Contractor Name: Phone: Email: Address: Supervisor's Construction License: Exp. Date: _ Home Improvement License: Exp. Date: ARCHITECT/ENGINEER Phone: Address: Reg. No. FEE SCHEDULE.BULDING PERMIT.$12.00 PER$1000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PER S.F. Total Project Cost: $ FEE: $ Check No.: Receipt No.: NOTE: Persons contracting with unregistered contractors do not have access to the guaranty fund ti `ianatu�P ®f�lAnt/®���nPr� Si +"'o'^fcontractor� Building Department e required forms to be filled out for the appropriate permit to be obtained. "n is a list of th � The following q Roofing, Siding, Interior Rehabilitation Permits Building Permit Application Workers Comp Affidavit Photo Copy Of H.I.C. And/Or C.S.L. Licenses Copy of Contract Floor Plan Or Proposed Interior Work Engineering Affidavits for Engineered products OTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit Addition Or Decks Building Permit Application Certified Surveyed Plot Plan Workers Comp Affidavit Photo Copy of H.I.C. And C.S.L. Licenses ► Copy Of Contract Floor/Cross Section/Elevation Plan Of Proposed Work With Sprinkler Plan And Hydraulic Calculations (If Applicable) Mass check Energy Compliance Report (If Applicable) Engineering Affidavits for Engineered products OTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit New Construction (Single and Two Family) Building Permit Application Certified Proposed Plot Plan Photo of H.I.C. And C.S.L. Licenses Workers Comp Affidavit Two Sets of Building Plans (One To Be Returned) to Include Sprinkler Plan And Hydraulic Calculations (If Applicable) Copy of Contract 2012 IECC Energy code Engineering Affidavits for Engineered products OTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg. Permit In all cases if a variance or special permit was required the Town Clerks office must stamp the decision from the Board of Appeals that the appeal period is over. The applicant must then get this recorded at the Registry of Deeds. One copy and proof of recording must be submitted with the building application Docg :Buildin Permit Revised 2014 A. Plans Submitted ❑ Plans Waived ❑ Certified Plot Plan ❑ Stamped Plans ❑ TYPE OF SEWERAGE DISPOSAL }. Public Sewer ❑ Tanning/MassageBodyArt ❑ Swimming pools ❑ Well ❑ Tobacco Sales ❑ Food Packaging/Sales ❑ Private(septic tank, etc. ❑ Permanent Dempster on Site ❑ THE FOLLOWING SECTIONS FOR OFFICE USE ONLY INTERDEPARTMENTAL SIGN OFF - U FORM PLANNING & DEVELOPMENT Reviewed On Signature_ COMMENTS CONSERVATION Reviewed on Signature COMMENTS HEALTH Reviewed ori Signature COMMENTS n Zoning Board of Appeals:Variance, Petition No: Zoning Decision/receipt submitted yes Y I Planning Board Decision: Comments Conservation Decision: ►soon: Comments Water & Sewer Connection/signafiure& Date Driveway Permit DPW Town Engineer: Signature: Located 384 Osgood Street t=z 4 FIRE`DEI?ARTMEMT'� Temp Dempster onEsife ;yes kL ted at 1. M ._S x3r' r r� ,-a� r=Fire ®epartment' ignature/date Ta ♦ pus�p �y �+ `;" , �w' a = _ ���� .�ti�, s. ' #{ � a''�1rr�.J 7L77#'J4`"ij'Ar= i�:•�F�.;'N����`t^5�'�, tr'F*`�'���.._ ""'� �i Dimension Number of Stories: Total square feet of floor area, based on Exterior dimensions. Total land area, sq. ft.: ELECTRICAL: Movement of(deter location, mast or service drop requires approval of Electrical Inspector Yes No DANGER ZONE LITERATURE" lies No MGL Chapter 166 Section 21A—F and G min.$1oo-$1000 fine NOTES and DATA— (For department use) i I ❑ Notified for pickup Call Email Date Time Contact Name Doe.Building Permit Revised 2014 Building Department I The following is a list of the required forms to be filled out for the appropriate permit to be obtained. Roofing, Siding, Interior Rehabilitation Permits Building Permit Application Workers Comp Affidavit Photo CoPY Of H.I.C. And/Or C.S.L. Licenses Copy of Contract Floor Plan Or Proposed Interior Work Engineering ,Affidavits for Engineered products OTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit Addition Or Decks Building Permit Application Certified Surveyed Plot Plan Workers Comp Affidavit Photo Copy of H.I.C. And C.S.L. Licenses Copy Of Contract ;rF Floor/Cross Section/Elevation Plan Of Proposed Work With Sprinkler Plan And Hydraulic Calculations (If Applicable) Mass check Energy Compliance Report (If Applicable) Engineering Affidavits for Engineered products OTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit New Construction (Single and Two Family) Building Permit Application Certified Proposed Plot Plan Photo of H.I.C. And C.S.L. Licenses Workers Comp Affidavit Two Sets of Building Plans (One To Be Returned) to Include Sprinkler Plan And Hydraulic Calculations (If Applicable) Copy of Contract 2012 IECC Energy code Engineering Affidavits for Engineered products OTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg. Permit In all cases if a variance or special permit was required the Town Clerks office must stamp the decision from the Board of Appeals that the appeal period is over. The applicant must then get this recorded at the Registry of Deeds. One copy and proof of recording must be submitted with the building application i Doc:Building Permit Revised 2014 I y � OF NORTF. q ` BUILDING PERMIT Z Zb+tt• r-•§ t6 � TOWN OF NORTH ANDOVER o APPLICATION FOR PLAN EXAMINATION '- � Z . Permit No#: Date Received SSACHUS�( Date Issued: IMPORTANT: Applicant must complete all items on this page LOCATION Print PROPERTY OWNER Print 100 Year Structure yes no MAP PARCEL: ZONING DISTRICT: Historic District yes no Machine Shop Village yes no TYPE OF IMPROVEMENT PROPOSED USE Residential Non- Residential ❑ New Building ❑ One family [I Addition El Two or more family El Industrial ❑Alteration No. of units: ❑ Commercial ❑ Repair, replacement- ❑Assessory Bldg ❑ Others: ❑ Demolition ❑_Other _ z peps t Wall - �FIo-odpl`a y1Ne,�,tla,E dsr� . Y7, Distr ctg �, � t ASateSevver±�Y DESCRIPTION OF WORK TO BE PERFORMED: Identification- Please Type or Print Clearly OWNER: Name: Phone: Address: Contractor Name: Phone: Email: Address: Supervisor's Construction License: Exp. Date: _ . Date: J Home Improvement License: Exp. ARCHITECT/ENGINEER Phone: Address: Reg. No. FEE SCHEDULE:BULDING PERMIT:$92.00 PER$9000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PER S.F. Total Project Cost: $ FEE: $ i Check No.: Receipt No.: NOTE: Persons contracting with unregistered contractors do not have access to the guaranty fund ,. ib -- i arf ; Dimension Number of Stories: Total square feet of floor area, based on Exterior dimensions. Total land area, sq. ft.: ELECTRICAL: Movement of Meter location, mast or service drop requires approval of Electrical Inspector Yes No DANGER ZONE LITERATURE: Yes No MGL Chapter 166 Section 21A—F and G min.$100-$1000 fine NOTES and DATA —(For department use) t Ott, �I ❑ Notified for pickup - Date _._....... Doc.Building Permit Revised 2012 Plans Submittedx❑ Plans Waived ❑ Certified Plot Plan ❑ Stamped Plans F TYPE OF SEWERAGE DISPOSAL Public Sewer ❑ Tanning/Massage/Body Art ❑ Swimming Pools ❑ Well ❑ Tobacco Sales ❑ Food Packaging/Sales ❑ Private(septic tank,etc. ❑ Permanent Dumpster on Site ❑ N/A THE FOLLOWING SECTIONS FOR OFFICE USE ONLY 1 INTERDEPARTMENTAL SIGN OFF - U FORM DATE REJECTED DATE APPROVED PLANNING & DEVELOPMENT ❑ ❑ 23(I COMENTS pts w w-e4`f S?LC., P4_rt4 tT bt., tm7 J u N- zo 1(. �al� c c�-[ ► l (�$�(�t7 vel `�'6��s krV k t i 4 5 EV 62 Le CtLnOVS C 0109 ScA�� v�e� A�o'rl �cl �. �n�s o r�,r�e�s Rei �� ()&+rd Jit L4 t% Zbt`o , CONSERVATION ❑ 9y N 4y COMMENTS Refi7 DATE REJECTED DATE APPROVED HEALTH ❑ ❑ COMMENTS Zoning Board of Appeals: Variance, Petition No: Zoning Decision/receipt submitted yes Planning Board Decision: Comments Conservation Decision: Comments • Water& Sewer Connection/Signature& Date Driveway Permit Located at 384 Osgood Street FIRE DEPARTMENT -Temp Dum ster on site yes no Located at 124 Main Street Fire Department signature/date COMMENTS Location /q C®C?, 3% 41 7Z f - No. ' Zu/7 Date • - TOWN OF NORTH ANDOVER Certificate of Occupancy $ Building/Frame Permit Fee Foundation Permit Fee $ Other Permit Fee $ TOTAL $ Check#A d 30552 �� Building Inspector NORT�y '9 Town Of I. 6Andover O .�. 0. No. —� �7 - CD�h ver, Mass, 201 A- COC111C441WIClt y1' 7a ADRATED 1S U BOARD OF HEALTH food/Kitchen PE T LD Septic System THIS CERTIFIES THAT .......... ...... ......................................................................................................... BUILDING INSPECTOR � Foundation has permission to ere .............. ......... buildings on �...��,a` I......................��...... ..�. �... � Rough to be occupied as . ..... Chimney provided that the person accepting this permit shall in every respectconfor to the terms of the application Final on file in this office, and to the provisions of the Codes and By-Laws r lating to the Inspection, Alteration and Construction of Buildings in the Town of North Andover. 04o W4UG_ys PLUMBING INSPECTOR VIOLATION of the Zoning or Building Regulations Voids this Permit. Rough Final PERMIT EXPIRES IN 6 MONTHS ELECTRICAL INSPECTOR U N LESS CONST CTION T Rough Service ... .... .... .......... Final BUILDIN NSP CTOR GAS INSPECTOR Occupancy Permit Required to Occupy Building Rough Display in a Conspicuous Place on the Premises - Do Not Remove Final No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. Burner Street No. Smoke Det. NO oT BUILDING PERMIT 3a ,.;:,. •'..° o� TOWN OF NORTH ANDOVER APPLICATION FOR PLAN EXAMINATION Permit NO: Date Received4A ,SS�ICHUSE� Date Issued: IMPORTANT:Applicant must complete all items on this page LOCATION Multiple Utility Pole Attachments-See plans provided herein Print PROPERTY OWNER National Grid Print MAP NO: N/A PARCEL: N/A ZONING DISTRICT: N/A Historic District yes no N/A Machine Shop Village yes no TYPE OF IMPROVEMENT PROPOSED USE Residential Non- Residential ❑ New Building ❑One family ❑Addition ❑Two or more family ❑ Industrial ❑Alteration No. of units: N Commercial ❑ Repair, replacement ❑Assessory Bldg N Others:Wireless telecommunicz tion ❑ Demolition ❑ Other utility pole attachments ❑ Septic ❑Well ❑ Floodplain ❑Wetlands ❑ Watershed District ❑Water/Sewer See plans provided herein. Identification Please Type or Print Clearly) OWNER: Name: National Grid Phone: (781)907-3455 Address: 40 Sylvan Road,Waltham,MA 02451 CONTRACTOR Name: Phone: (207)642-5751 Kyle Purrington-Wireless Construction, Inca Address: 40 Blake Road,Standish,ME 04084 Supervisor's Construction License: Exp. Date: CS-103000 09/14/2016 Home Improvement License: Exp. Date: N/A N/A ARCHITECT/ENGINEER Hudson Design Group, LLC Phone: (978)557-5553 Address: 1600 Osgood St., Building 20 North,Suite 3090, Reg. No. N.Andover,MA 01845 FEE SCHEDULE.-BULDING PERMIT.$12.00 PER$1000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PER S.F. Total Project Cost: $ 210,000.00 FEE: $ 2,520.00 Check No.: -� 3'I y Receipt No.: <)cp 15 �- NOTE: Persons contracting with unre istered contractors do not have access to the guaranty fund Signature of Agent/Owner Please a li nse attached Signature of contractor Please see attached. Plans Submitted 0 Plans Waived ❑ Certified Plot Plan ❑ Stamped Plans TYPE OF SEWERAGE DISPOSAL Public Sewer ❑ Tanning/Massage/Body Art ❑ Swimming Pools ❑ Well ❑ Tobacco Sales ❑ Food Packaging/Sales ❑ Private(septic tank,etc. ❑ Permanent Dumpster on Site ❑ N/A THE FOLLOWING SECTIONS FOR OFFICE USE ONLY INTERDEPARTMENTAL SIGN OFF - U FORM DATE REJECTED DATE APPROVED PLANNING & DEVELOPMENT ❑ ❑ � �� ' �� COMENTS PEI, gC-e- � ! {HC., '-104ri _bKR_7 -��t' 1 ZO1 , L-J, cc*'Gy...5- )f4 -11T-kc Heko -Tl\%s ko-k i t 4 5 CZ3� rj Lc ca-ndu C&j%q 5c4-c-) v nver- pie-n c -icy. �aju I rtiAc,-Ts Ref CONSERVATION ❑ ❑ qqq— qy COMMENTS DATE REJECTED DATE APPROVED HEALTH ❑ ❑ COMMENTS Zoning Board of Appeals: Variance, Petition No: Zoning Decision/receipt submitted yes Planning Board Decision: Comments Conservation Decision: Comments Water& Sewer Connection/Signature&Date Driveway Permit Located at 384 Osgood Street FIRE DEPARTMENT - Temp Dumpster on site yes no Located at 124 Main Street Fire Department signature/date COMMENTS i CHRISTOPHER A.SWfNIARSKI Direct Dial:603.628.1322 Email:christopher.swiniarski@mclane.com CLANE Admitted in NH and MA 900 Elm Street,P.O.Box 326 MIDDLETON Manchester,NH 03105-0326 T 603.625.6464.6464 F 603.625.5650 June 28, 2016 VIA HAND DELIVERY Mr. Donald Belanger, Inspector of Buildings Town of North Andover 1600 Osgood Street Building 20, Suite 2035 North Andover, MA 01845 Re: Building Permit Application to Attach Small Cell Antennas and Supporting Equipment to Existing Non Municipal Utility Poles Applicant: Cellco Partnership d/b/a Verizon Wireless ("Verizon") Address: Utility Pole # MECO 1460 located in public right of way at 521-623 Dale Street Utility Pole# MECO 31 located in public right of way at 250-336 S. Bradford Street Utility Pole# MECO 4726-5S located in public right of way at 700-850 Dale Street Utility Pole# 5222 located in public right of way at 1 Russett Lane in LLfl �jj , j )tility Pole-#-MEET&3'Co 2/231;<#=I611<located=in.public=rightrof-7way 99- atT494=498'Ipswich50a Utility Pole# MECO 1 located in public right of way at 1-99 Bannan Drive Utility Pole# MECO 2424/1 located in public right of way at 874 Salem Street Dear Mr. Belanger: The purpose of this letter is to deliver the enclosed Building Permit Application to attach small cell antennas and supporting equipment to the seven (7) above-referenced sites. The purpose of the small cell antennae are to strategically address and remedy a significant wireless coverage gap in North Andover. McLane Middleton,Professional Association Manchester,Concord,Portsmouth,N/H�J Woburn,Boston,MA pr Pf McLane.com Mr. Belanger, Inspector of Buildings June 28, 2016 Page 2 Please note that on June 7, 2016, the North Andover Office of the Planning Department approved Verizon's application issuing a special permit for each of the above-referenced sites. As such, Verizon respectfully submits the following materials: 1. $2,520.00 check for the Building Permit Application; 2. Town of North Andover Building Permit Application; 3. Town of North Andover special permit decision; 4. Proof of liability insurance; 5. Workers' compensation insurance affidavit; 6. Photo of CSL license; and 7. Two (2) 11" x 17"plan set per each of the seven (7) sites. Verizon respectfully requests that the Town of North Andover Building Department issue a building permit for this project. Please do not hesitate to contact me with questions. Sincerely, Christop r A. Swiniarski CSW:t 104160\10886779 CHRISTOPHER A.SWINIARSKI Admitted in NH and MA McLane Middleton,Professional Association 900 Elm Street Manchester,NH 03105 { Direct Dial:603.628.1322 *�.f Email christopher.swiniarski@mclane.com IN July 19, 2016 Via Hand Delivery Rebecca Oldham, Planner Town of North Andover 1600 Osgood Street North Andover, MA 01845 RE: Pre-Building Permit Requirements - GRAN Wireless Service Facilities located on existing utility poles, proposed by Cellco Partnership, d/b/a Verizon Wireless ("Verizon") Hello Rebecca: Pursuant to your email to me from July 11, 2016, 1 have enclosed two (2) copies of the recorded special permit decision associated with the above-referenced project, and a check for $10,000.00 to serve as a bond as referenced in the aforementioned decision. With resp[ect to the construction schedule, each installation will take approximately three (3)days, with an anticipated maximum of five (5) days. Verizon contractors will notify you, via email, not less than two (2)days prior to beginning installation. Verizon or its contractors will also notify the property owners abutting each pole two (2) days prior to beginning installation. I trust this information, combined with the building permit applications submitted on July 1, 2016, satisfies the requirements for issuing the permits requested. AS always, please feel free to contact me directly should you have any questions. Thank you. Sincerely, Christopher Swiniarski Attorney for Verizon Wireless 102438\10975050 1 q � C 11'^" ;ORT" )",,' Town of North Andover � �'^E Office of the Plannin De p g Department p 2016 JUN -8 Ali 11: 25 Community Development and Services Division A 1600 Osgood Street ,; 1 OF �'9s"4*I°°Ec North Andover,Massachusetts 01845 P,O< S�cHus MASSM,'Ifl S 1!z NOTICE OF DECISION WIRELESS SERVICE FACILITIES SPECIAL PERMIT Any appeal shall be tiled within(20)days after the date of filing this notice in the office of the Town Clerk. Date: June 7,201.6 Date of Hearings: May 3,2016,May 17,2016, June 7,2016 Date of Decision: June 7,2016 Application of: CELLCO PARTNERSHIP,D/B/A VERIZON WIRELESS C/O McLane&Middleton Premises Affected: Name of Site Address Verizon Wifeless—Lawrence CRAN 11 Turnpike Street Verizon Wireless—North Andover CRAN 20 740 Turnpike Street Verizon Wireless North Andover SC03 222 Great Pond Road Verizon Wireless—North Andover SC05 678-686 Great Pond Road Verizon Wireless—North Andover SC06 692 Great Pond Road Verizon Wireless—North Andover SC07 920 Great Pond Road Verizon Wireless—North Andover SC09 38-112 Salem Street Verizon Wireless—North Andover SC 11 313 Salem Street Verizon Wireless—North Andover SC 12 124-158 Dale Street Verizon Wireless—North Andover SC 13 362-530 Salem Street Verizon Wireless—North Andover SC 14 208-418 Dale Street Verizon Wireless North Andover SC 15 521-623 Dale Street Verizon Wireless—North Andover SC16 250-336 S.Bradford Street Verizon Wireless—North Andover SC 17 700-850 Dale Street Verizon Wireless—North Andover SC 18 250-336 S.Bradford Street Verizon Wireless—North Andover SC20 700-850 Dale Street Verizon Wireless—North Andover SC23 874 Salem Street Verizon Wireless—North Andover SC27 287-361 Chickering Road Verizon Wireless—North Andover SC28 452 Chickering Road Verizon Wireless—North Andover SC29 57-99 Parker Street Verizon Wireless—North Andover SC30 532 Chickering Road Verizon Wireless—North Andover SC32 406 Osgood Street Verizon Wireless—North Andover SC34 722 Osgood Street Verizon Wireless—North Andover SC35 982 Osgood Street Referring to the above petition for a Wireless Service Facility Special Permit,in accordance with the requirements of the North Andover Zoning Bylaw, Sections 8.9 Wireless Service Facilities and Section 2.65 Special Permit Granting Authority,in order to attach disguised Cloud Radio � I I Wireless Service Facilities Special Permit CeIlco Partnership,D/B/A Verizon Wireless June 7,2016 Access Network(C-RAN)antennae,a single 24.2"tall cylindrical canister weighing approximately twenty two(22)pounds,and additional supporting equipment,consisting of a remote radio head,electrical junction box and meter,and fiber optic connections,mounted to twenty four(24)existing utility poles,owned by National Grid,at the locations set forth above. Upon a motion by David Kellogg and a 2nd by Lynne Rudnicki, the Planning Board hereby APPROVES the issuance of a Wireless Service Facilities Special Permit by a vote of S in favor and 0 against. On beh of the North Andover Planning Board John Simons,Chairman Lynne Rudnicki David Kellogg Lora McSherry Peter Boynton 1 2 i i Wireless Service Facilities Special Permit CelIco Partnership,D/B/A Verizon Wireless June 7,2016 The Planning Board herein approves the Special Permit to attach disguised Cloud Radio Access Network (C-RAN) antennae, a single 24.2" tall cylindrical canister weighing approximately twenty two(22)pounds,and additional supporting equipment, consisting of a remote radio head, electrical junction box and meter, and fiber optic connections, mounted to twenty four (24) existing utility poles,owned by National Grid,at the locations set forth above.The Special Permit was requested by Christopher Swiniarski, Attorney for Verizon Wireless. This application and additional documentation as cited herein were filed with the Planning Board on March 8, 2016. The Applicant submitted a complete application which was noticed and reviewed in accordance with Sections 8.3, 8.9, 10.3, and 10.3.1 of the Town of North Andover Zoning Bylaw and MGL c.40A, Sec.9. The Planning Board finds that the applicant has met the following requirements as required by the North Andover Zoning Bylaw Section 8.9: FINDINGS OF FACT: 1. The Applicant's Attorney, Chris Swiniarski, provided testimony that there is an existing substantial gap in coverage in the vicinity of the proposed installation and that the facility is necessary in order to substantially close the gap in coverage. 2. The Town's Wireless Review consultant has reviewed the application and has found that the proposed installation of twenty four(24) utility pole mounted facilities in the public ways is consistent with the overall principles and preferences under the zoning bylaw. (Please see Consultant Review Memo from David Maxson with Isotrope dated April 22, 2016). 3. Per the Town's Wireless Review Consultant findings, the Applicant has provided theoretical RF field calculations, from a certified Radiation Safety Specialist,data for the seven (7) sites that fall below the height exemption to indicate the summation of the proposed Verizon Wireless RF contributions. The Specialist confirmed that these contributions would be well within the established RF exposure guidelines at"the typical facility installation using a nominal height above ground that matches the lowest height proposed (25'6")". (See correspondence from Donald L. Haes, Jr. PH.D., CHP dated May 9,2016). 4. The Telecommunications Act of 1996 prohibits this Board from taking health effects of RF transmissions into account beyond FCC requirements. 5. The Applicant has provided evidence that they have a legal right to install the wireless facility as proposed.(See correspondence from National Grid from Amy Sullivan dated October 20,2015). 6. Adequate and appropriate facilities will be provided for the proper operation of the proposed use. The proposed antennas cables and equipment area are described in detail on the plans and reports referenced herein. 7. The Building Commissioner has determined that the"antenna"is so placed on an existing structure and that the existing structure is a non-conforming structure and therefore wireless facilities and their equipment do not increase their non-conformity. Therefore, 3 i Wireless Sei vice Facilities Special Permit Cellco Partnership,D/B/A Verizon Wireless June 7,2016 the Applicant does not need to petition the North Andover Zoning Board of Appeals for a variance under Section 8.9.3(c)(v)(1).(See determination letter dated December 3,2008). 8. The application meets all of the filing requirements of the Wireless Service Facilities By- law Section 8.9, and the filing requirements of Site Plan Review, Section 8.3, with the exception of the waivers granted listed below: Waivers The installation will be constructed according to the Plans, with the following waivers granted by the Town of North Andover Planning Board, according to the provisions of the Town of North Zoning Bylaw. These waivers are hereby granted in consideration of the installation as a pre-existent installation and a co-location: ; 8.9(5)(d)(ii)(4) A map showing the other preexistent and approved wireless service facilities in North Andover and outside North Andover within one mile of its boundary. Applicant may be aware of other carriers but is not in a position to provide a multicarrier inventory. I I 8.9(5)(d)(H)(5) GPS all equivalent system locating by latitude and longitude wireless service facilities.The equipment will be placed on existing utility poles. i 8.9(5)(d)(iii)Siting Filing Requirements.A one-inch-equals-40 feet plan prepared by a Registered Professional Engineer in the Commonwealth of Massachusetts showing the following: (1) Property lines for the subject property. Existing utility poles are on the public way. (2) Property lines of all properties within 300 feet of the proposed location. Existing utility poles are on the public way. (3) Tree cover on the subject property and all properties directly abutting the subject property, by dominant species and average height. This is impracticable on the public way. j (4) Outline of all existing buildings, including purpose (e.g. residential { buildings, garages, Accessory structures, etc.) on subject property and all properties adjacent to the subject property.The level of detail provided in the site documents is sufficient to see the locations in context with nearby buildings and uses. (5) Proposed location of antenna, mount and equipment shelter(s). All equipment will be attached to existing utility poles. I (6)Proposed security barrier, indicating type and extent as well as point of I controlled entry.No security barriers are necessary. (7)Location of all roads,public and private,on the subject property and on all adjacent properties within 300 feet including driveways proposed to serve t the wireless service facility. Site plans submitted are sufficient for the application. (8) Distances, at grade, from the proposed wireless service facility to each building on the vicinity plan. Site plans submitted are sufficient for the application. (9) Contours at each 2 feet AMSL for the subject property and adjacent properties within 300 feet. Site plans submitted are sufficient for the r 4 x ' C - 3 Wireless Service Facilities Special Permit Cellco Partnership,D/B/A Verizon Wireless June 7,2016 application. (10) All proposed changes to the preexistent property, including grading, vegetation removal and temporary or permanent roads and driveways. No changes are proposed. (11) Representations, dimensioned and to scale, of the proposed mount, antennas, equipment shelters, cable runs, parking areas and any other construction or development attendant to the wireless service facility. No changes are proposed. (12) Lines representing the sight line showing viewpoint (point from which view is taken) and visible point (point being viewed) from 'Sight Lines" subsection below.Site plans submitted are sufficient for the application. (13) Location of all wetlands on the subject property and within 100' of the proposed facility as approved by the Conservation Commission. No ground disturbance is proposed. 8.9(5)(d)(iv)Site Lines and Photographs Not applicable. 8.9(5)(d)(v)Design Requirements Not applicable. 8.9(5)(d)(vi) Noise Filing Requirements No noise making machinery involved in the system. 8.9(5)(d)(vri)Radiofrequency Radiation(RFR)Filing Requirements (2) In order to determine compliance with applicable FCC regulations, the applicant shall provide a statement listing the preexistent and maximum future projected measurements of RFR from the proposed wireless service facility,including all co-locators,for the following situations: (a)Preexistent or ambient:the measurement of preexistent RFR.No wireless facilities exist at each location. (b) Preexistent plus proposed wireless service facilities: maximum estimate of RFR from the proposed wireless service facility plus the preexistent RFR environment. No wireless facilities exist at each Iocation. All proposed installations with antenna centerlines greater than or equal to 31 feet 2 inches above ground are exempt from routine evaluation for RFR compliance under federal regulation (Table 1, 47 CFR 1.1307).The following sites do not fall within the FCC exemption: f SC 30,SC 27, SC 17,SC 16, SC 06,CRAN 11,CRAM 20;see finding of facts number two(2). (c) Certification, signed by an engineer, stating that RFR measurements are accurate and meet FCC Guidelines as specified in the Radiofrequency Radiation Standards subsection of this Bylaw. No wireless facilities exist at each location. All proposed installations with antenna centerlines greater than or equal to 31 feet 2 inches above ground are exempt from routine evaluation for RFR compliance under federal regulation (Table 1, 47 CFR 1.1307). The following sites do not fall within the FCC exem tion: SC 30, SC 27, SC 17, SC 16, SC 06, 3 CRAN 11,CRAN 20;see finding of facts number two(2). (3) Applicant must submit a copy of the letter from the Massachusetts Department of Public health approving the site for this facility as required by 5 "F r e !I I Wireless Service Facilities Special Permit j Cellco Partnership,D/B/A Verizon Wireless June 7,2016 3 105 CMR 122.000 requires that the Department of Public Health approve all sites for wireless facilities with respect to emissions. The Massachusetts Department of Public Health no longer requires notifications and approvals under 105 CMR 122.000.(See memorandum dated March 15,2002) 8.9(5)(4) (viii) Federal Environmental Filing Requirements No hazardous materials are proposed. Finally the Planning Board finds that this project generally complies with the Town of North Andover Zoning Bylaw requirements as listed in Section 8.9 but requires conditions in order to be fully in compliance. The Planning Board hereby grants an approval to the applicant provided the following conditions are met: SPECIAL CONDITIONS: 1) Discontinuance Abandonment a) At such time that a licensed carrier plans to abandon or discontinue operation of wireless service equipment, such carrier will notify the Town by certified US mail of the proposed date of abandonment or discontinuation of operations. Such notice shall be given no less than 30 days prior to abandonment or discontinuation of operations. 1n the event that a licensed carrier fails to give such notice, the wireless service equipment shall be considered abandoned upon discontinuation of operations. b) Upon abandonment or discontinuation of use, the carrier shall physically remove the wireless service equipment placed on the site by the carrier within 90 days from the date of abandonment or discontinuation of use. "Physically remove" shall include,but not be limited to: i I i) Removal of antennas,mount,equipment shelters and security barriers installed by the carrier (unless the same will continue to be used by the owner) from the subject property. n ii) Proper disposal of the waste materials generated by the cagier from the site in accordance with local and state solid waste disposal regulations. iii) Restoringthe location of the wireless service facility ty in its condition before the � installation,except that any landscaping and grading shall remain the after-condition. c) The equipment shall be deemed to be abandoned or discontinued if it has not been used j for the purpose for which it was originally constructed for a period of six(6) months or more. Once abandonment or discontinuance has occurred, the carrier shall remove the equipment from the subject property within ninety days. P4 2) After the equipment on the facility is in operation, the Applicant shall submit to the SPGA, within 90 days of beginning operations and at annual intervals from the date of issuance of the Special Permit, current RFR measurements. Such measurements shall be signed and I certified by an RF engineer, stating that RFR measurements are accurate and are in compliance or why the measurements fail to comply with all applicable FCC Guidelines as specified in Section 8.9(5)(d)(vii)RFR Filing Requirements of this Bylaw. h� 6 f t I i Wireless Service Facilities Special Permit Cellco Partnership,DB/A Verizon Wireless June 7,2016 3) The Applicant or their successor in interest shall maintain the wireless service equipment in good condition. Such maintenance shall include, but shall not be limited to, structural integrity of the antennas. 4) Annual Certification Annual certification demonstrating continuing compliance with the standards of the Federal Communications Commission, Federal Aviation Administration and the American National Standards Institute, if required by those agencies,shall be filed with the SPGA by the Special Permit holder. 5) Prior to Issuance of a Building Permit: a) Two(2)recorded copies of the signed,recorded decision and the recorded plans must be delivered to the Planning Department. b) A bond in the amount of ten thousand dollars($10,000) shall be posted for the purpose of insuring that a final as-built plan showing the location of all on-site structures. The bond is also in place to insure that the site is constructed in accordance with the approved plan. This bond shall be in the form of a check made out to the Town of North Andover. This check will then be deposited into an interest bearing escrow account. c) A construction schedule shall be submitted to the Planning Staff for the purpose of tracking the construction. d) The Applicant will inform the direct utility pole abutters of installation. 6) Prior to the final release of security a final as-built plan showing final construction and location of the wireless hardware shall be submitted to and reviewed by the Planning Staff. The Applicant must submit a letter from the architect or engineer of the project stating that the construction and operations substantially comply with the plans referenced at the end of this decision as endorsed by the Planning Board. 7) The provisions of this conditional approval shall apply to and be binding upon the applicant, its employees and all successors and assigns in interest or control. 8) Any revisions shall be submitted to the Town Planner for review.If these revisions are deemed substantial,the applicant must submit revised plans to the Planning Board for approval. 9) This Special Permit approval shall be deemed to have lapsed after three years from the date permit granted unless substantial use or construction has commenced. Substantial use or construction will be determined by the Town Planner. 10)The following information shall be deemed part of the decision: i a) Application Titled: Application for Special Permit Cellco Partnership,D/B/A Verizon Wireless c/o McLane&Middleton 900 Elm Street Manchester,NH 03105 Prepared for: Cellco Partnership,D/B/A Verizon Wireless , 7 i I f Wireless Service Facilities Special Permit Cellco Partnership,D/B/A Verizon Wireless June 7,2016 b) Documentation Submitted: 1 Town of North Andover Planning Board Application for Special Permit; 2 Antenna specifications: Pole Address Engineering Firm Plan Dates s/ Lawrence MA CRAN 11 89 Turnpike Street Drewberry Engineers,Inc. Dated 3/10/2015 Revised 3/27/2015; 8/14/2015; 1/12/2016 N Andover SC03 MA 222 Great Pond Road Hudson Design Group, Dated 7/20/2015 Inc. N Andover SC05 MA 678-686 Great Pond Hudson Design Group, Dated 5/17/2015 Road Inc. N Andover SC06 MA 692 Great Pond Road Hudson Design Group, Dated 7/22/2015 Inc. N Andover SC07 MA 920 Great Pond Road Hudson Design Group, Dated 7/23/2015 Inc. N Andover SC09 MA 38-112 Salem Street Hudson Design Group, Dated 7/20/2015 Inc. N Andover SCI I MA 313 Salem Street Hudson Design Group, Dated 7/22/2015 j Inc. J N Andover SC 12 MA 124-158 Dale Street Hudson Design Group, Dated 7/21/2015 j Inc. s N Andover SC13 MA 362-530 Salem Street Hudson Design Group, Dated 7/20/2015 Inc. N Andover SC14 MA 208-418 Dale Street Hudson j Design Group, Dated 7/17/2015 � Inc. N Andover SC15 MA =521-623e Street Hudson Design Group, Dated 7/22/2015 Inc. F N Andover SC16 MA 250-336 S.Bradford Hudson Design Group, Dated 7/23/2015 b Street Inc. _ E N Andover SC 17 MA 700-580 Dale Stree Hudson Design Group, Dated 7/21/2015 ; Inc. V/ N Andover SC 18 MA 1 Russett Lane Hudson Design Group, Dated 7/20/2015 �— Inc. k { I 8 I C Wireless Service Facilities Special Permit Cellco Partnership,D/B/A Verizon Wireless June 7,2016 �T N Andover SC20 MA C99 Bannan Drive Hudson Design Group, Dated 7/23/2015 8 , _ Inc. N Andover SC23 MA 874 Salem Street Hudson Design Group, Dated 7/23/2015 Inc. N Andover SC27 MA 287-361 Chickering Hudson Design Group, Dated 7/24/2015 Road Inc. N Andover SC28 MA 452 Chickering Road Hudson Design Group, Dated 7/21/2015 Revised Inc. 8/19/2015 N Andover SC29 MA 57-99 Parker Street Hudson Design Group, Dated 7/22/2015 Revised Inc. 10/1/2015 N Andover SC30 MA 532 Chickering Road Hudson Design Group, Dated 7/23/2015 Inc. N Andover SC32 MA 406 Osgood Sheet Hudson Design Group, Dated 7/22/2015 Revised / Inc. 8/9/2015 V N Andover SC34 MA 722 Osgood Street Hudson Design Group, Dated 7/23/2015 Inc. V N Andover SC35 MA 982 Osgood Street Hudson Design Group, Dated 7/23/2015 g g P� Inc. V N Andover MA CRAN 20 740 Turnpike Street Hudson Design Group, Dated 4/28/2015 Inc. 3 Map of all proposed 24 locations; 4 Certified Abutters' List; 5 Review Report,dated April 22,2016,Prepared by David Maxson; 6 Radio Frequency(RF)calculations prepared by Donald L.Haes,Jr.PH.D.,CHP dated May 9,2016; 7 List of proposed North Andover utility pole attachments with existing guy wires. f { Cc: Applicant Abutters i i n s li 9 r i N LAWRENCE MA CRAN11 s NORTH ANDOVER,MA VICINITY MAP u"^ LEASE EXHIBIT POL<LOCATION- �• 2 Ol 12 16 FOR SUBMITTAL OB ,jr, SUBMRTAL Y c - 1r tC 0 0.7/27/15 FOR SUBMRTAL A 03/10/15 I FOR COALNENT 710 4r' J w.n4.rcNT• c" Dewberrgo Dewberry Engineers Inc. ' SN,lFMA'MFFi rnea,.d.m Ina, - . of,t771+NR jr 4W 37.4r � &1 DRAnN Br: aG1 jw -r '�' flENENEU 9n 6A5 w t'. :-.f mQLRm uY: OBR •`^.r- - '_{g� PxOJECi Xwom 30002033 —am 300]0913 #2231-84 S ? '� N 42' 40' 37.42" ,• fcRn,rs ivmmowac z ",.' W 71' 07' 51.50" i soon aisnn.a0 PnoPosm u+Fo9wlmn uor � + ""' socxw ron ou9nr. a. muvuwr rnuumm wm aP:wcaxxl PElmgc "'� _ r,unnsr vmEr: SI9UCRIUL.I"Ya50 um mswu. ''a _ TM6 ooaaro+r a ron wavc PWIPOSES may. �T ron eoxsmuene� TURNPIKE STREET S. Pcm oro T0A0 TO ml[FAOM Dmm N. ANDOVER, MA 01845 Itt9.SeONCE SO9RCe m Iff ^� %M TME a ane Pun a evv trou^,vrsm m+srtn vr�r m VICINITY & AERIAL MAP j AERIAL MAP CN 03/ a AOi4i h 1VP3 0�SE0 GY CCAIXE GRIN SUlC:ors. asumm cu a/ra sue2T ruin LE-1 f LAWRENCE MA CRAN11 i LEASE DCHIBff z o+ 72 18 FOR SUBMaTAL 08 I4 75 FOR SUBMrrrAL ,,. ' « 0 03/27/75 FOR SUBMITTAL N.x A 0.3/10/75 FOR COMM.ENi Ao°V5 FO4Ls. � •1. A NAIIdUI Sim _Z2 1- T f �� zoul N..Dar-uinur iir 3 .T1•W Sim _=� Dewberry Dewberry Engineers lr tQ nN OMAN" � rA� IANiSPCInATON � yw �.. r .n '� "` OKtltfD 8f: Be11. PRe=r"mm SCOO2D23 JD8 NUYOF7C SOQ70D73 ' y'f h.I PML N. #2231-84 e woraTNvs N 42' 40' 37.42" max W 71' 07' 51.50" 1. NORM R APDR=WL L —mis AAD PROPDS:p n+FDRNAnav eR1r AERIAL IMAGE 1uAarsr srncv: SH MN FOR CLVM. :1 1'�tOD•f08 33•stt' TURNPIKE STREET DE/M/1s IDD oN ROAD 4A7)rIDRY O5 64AeA5 POR T2 MASSACXUREr15 ofPMnIDR DF 7T,wsroRr m.DxDUNID w 1=r1v11 0• 1� N. ANDOVER, MA 01845 4 ROAD SDDDNNt RISFD ON STAID FEIMWY UIYgIT SiiET MI£ FOR MASSAOUE/ OPPARI11DYr S 11R�Int6�P®DA}pN DSrAL®DII 1T/11/ri UlDlrt ND.n•W1-1. 1 wa FaNr DASSD Dx txc u aAonnms ROAD TYPE JURISDICTION DFaAwnm T PSL & STATE HIGHWAY LAYOUT cxeo¢n ax m/1 i/IS 0. D°DRNATON OkPIC1D7 ON 11M15 OAA'MOS NAS Nm - SMDS xUNBDE DAEM VE7ERE9 TiROUOX A FWD SURNEY RLVIRIY 8f MASSAGIUSTS REO6TFRFD LAID 8Y@flOR. T. POLE LOGTDx 910'Mi AS APPAO)WAX LE-2 PROPosm Lmsws LAWRENCE NIA Y. CRAN11 Al2W&,'DIA , ✓ 'N'" N ClM' 9OVN EO TO PDl£(Sm ND,E 3) +J�_ CA.OF PnON519 ANfEN.W ,93'-2'(IUWPd) P"uaEia..• uwsl:H rvc LEASE IXHIBfi 9RMKEi(CRa� R r 01 Ex4•Sm V.IRlr P. z h - $ -191'-2'(rcAVD99) PROPOSED lFS5EE5 ' 1/2•cDDx w ,_,.. ( s•u-DUMD tPOLEa""D E.y 2 01/12/16 FOR SUBMRTAL M.(n i0�M'A) tel. P6ari 0SFD LESSEES OB~ T 14/15 FOR SUBMITTAL d' ArouED To nxe --'--�^'--On-.�O'bl'n9 PP•er Line 0 03/27/151 FOR SVBNRTAL na.•..21•'-T-s wG:. A 03/10/151 FOR COMMENT y/ PROPOSED mm" ' nO w 2•U-CUMD PROPDSm ILSErF'9 MOUNTED TO POLE AVIL\•NA tOUN1Ep TO 3) Vlra RnJ Dewberry- 1 TOP OF Pw.E e(SEF NO[E 3) / -p„x Exnilnq Overread iFaea \ PEERED' [�� E OBwberry Engin�aeesa srRcsr .. -' `� I o,n Fav�F'amg Dva.MeO txroa �ORiAworlo IOgS POLE Ebv..30'-Yi AG:. p;T.EySJopp • f 1,. H 4r 4L CRO®/931-91 FNL 6:>AfYAtO (:OORORWES: /�+.•• Ex61M0 n 4r 10'5Ar o.arnem w Tr or suo• E.edeR � aarnaad 3 PROP0.9CD tLS3¢'S 2 PRH2%00 MOVNfEp roe INAIVN sn. JCN 11 POLE(SEE NOTE 3) PROPOSED DETAILED SITE PLAN 2 E awa UIr1Y SCa[Ef 1/1'F FDR 11 rl]' Stu>-UD RYD•) pENEbItD,n': OAS �:. 1'.t'FOR 9•cSf' PROPOSED Ii.. 9TO D® f DL o UIE1ttUPOLE TO GfECNED N': e91t PROPOSED LESSEES P-cr NUMB 50002025 PO�Rm70 CONOLPOp.E 3®HIMSER SOOT091J POLE Ar SODS O PROPOM LE sws LPRIJIY METER"`*"r"ti mm LS MB+OONATE To E,Osmc uru,T POLE #2231-84 ,M 2 SONS OIISTIND M0 PRDPDSZD NPOmtaTror XOT Exie9rp Red SXCNN iClt G.vN1T. Youxee ie PROPOSED LESSWS ` ECRINi[D TO PO,z TS :* ♦yy1 . l EONPYFNT MDUMINO AND DPoEMARCN PE11OwO PNa�w') oRO'M CONODD Srm:COEUI N _s MO oal N I" 4 Tm DCVNENf fi FDR LLSIN.^.PNRP036 PNC.NOr FDR C. urnox wcn POLE N 42. 40' 37.42• - - •�. w MNA CMD mg 2231-91 PDMER uN 1ELL9 1D WNE FlIOM COStwO O.a7iNEMI k coon MM—MM.M.SwIc9 TO OE OErERuoum. cooRoiNArEs: W 71' 07' 51.50'' y, 3 4z 1c Z7 42' 4':` ,¢S "+ 6. SIZE PtM @ ELEVATOM.HASm ON 511E V6R m NTC Or Std' omom E.\•umc wG oN az/2s/1s. \yi`,+G"rC ,� ". 2. tmLnr POLE wwoxu:cs a ncr Oe ewsm w � NFDnEsr sr>&Er. FAA-2D SURVEY. TURNPIKE STREET N. ANDOVER, MA 01845 ,. oNoro war aV o2J23/,s — �•we—� SI�ET TmE a POLE PHOTO & UTILITY POLE#2231-84 PHOTO CONCEPTUAL ELEVATION sr c•X.TS, l CONCEPTUAL POLE ELEVATION srALE:t/�--r F'OR 11N,r 3 sIt2T MPI9ER FOR 22W4' O r r 4' LE-3 LAWRENCE MA CRAN11 ANMM LEASE EXHIBIT • xr 2 01 12 16 FOR SUBMITTAL 1 OB 14 15 FOR SUBMITTAL UtrU1Y PotE 0 03 27/15 FOR SUBa111TAL A 03/10/15 FOR COMMENT 61fi1 m (7a0 TMI _ 'L a SECONMPY • Dewberry- 0. 00wbony Engineers Inc. ' xnaumsmoa 10+N OR uas+ox.0 m:+o aa011N0 Hans,ori.omJom j SM-O J/ � RAx 61TTi£b10 �J.., FiBFR FRONnLWLJ s...�t B.CNNWL RRN [614"RR) F�' P.MLwED ec oAs I FF t • aaNYEPIEP t) F PPGhR NUN6Eh SC:G28]S a s ECUI cz Paz V. 12o/24ov #2231-84 S�PRY� W01mINhhlF4! N 42' 40' 37.42" nPra amaNn MEiQ2 soarer °R0u"o W 71' 07' 51.50" YODEL 11U B4 PPH2n6a-4P AWS Nwcesr srrlar. rr.e, m1SNsioN2 ar'P.+IV.WO WOCMn 55 WS.T/e TCwx6r1 oos TURNPIKE STREET 2t I=(wm1 ePPalep +. mac, aLooPc Po�rnPC nNn oercP N. ANDOVER, MA 01845 ANIENMA��FTtn1'�TaNC GENERAL WIRING DIAGRAM SHEEr IYU a1MFNSI0N6:IOX0•24XW SCJl.E•N.TS. 3 REM'3 SSS' RRH DETAIL � EQUIPMENT DETAILS_ - SGYE N.TS. 2 SENNA DETAIL 1 LE-4 LAWRENCE MA Arraw board ShodawvohWo CRAN11 Arrow hggrJ supporl artfallor O 00 ial W'.facing down) 11"', Sian(xhmrn fach,p Intl) Changea0lo maaago Sign or seaport tnller ® 3u—p' ® Chgnnenlh,g ci wea Tompotary asrrlor LEASE EXHIBIT F:a) Cmi,mchlen ® 7tmommy-Ma—im wamino Bght 1. Au wHSTrtucnex:ralwc,oms�avaaGoc,,un "Cw orvar seuu �MM RAar a umnvy traffic datour 'IUPORART D FCC TMn'IC COMIiet'nr 30eq M.111U.1'Ox kn Of lC Trafgq at odoottInn al mit uHuaRra mune cavmaL m.�(Nu:o7,Artsr P g Re+4oH. -.► Dime.ion of tralna 2 07/12/15 FOR SUT1 L t 1EFlpalwrr 1PA,Ac epFmiCL 2aNE ME Tmlut Truck-m0{a,forl nTOnaalOr 1 W14/15 15 FOR SUBMITTAL APPUGTONa q[SICNB$xgvM FW CCI:QUL � t]ggmr RL,EREMEC ONLY ANq!AE NOT m 0E V9m mR 0 03/27/15 FOR SUBMrTTAL COHBrilUETOH PORP096.fiW1 TRAFFIC £xr rAeaiEFn,�AcwmM xn^.qo�T aiFtlA� � FGpM1-Imglwarnlnpaav(co ^® IYPa 31L1nl:gtlq A 03/10/15 FOR WuIIENT %:R%Ogµwm ar uAss vm rmroR To tFLiO Heol ,1L, cl/ntntnp Ilpht. >. mmHmx�e mmK11c cgr =,w REqumm m l_J APPUueIE%Z AHq Lova.Aaa1L44 c © LonplludlmM charw,elizing tlavico ® y v ACOOF81elE MOI TIE PUNS AND,O,CW 7.q0: De1�8J�i�y LLS[Cf AOW MCGEIS A!a NllpL CRY{=CH WWkaPano �woR�RRw2ers.Ivro AnR,austE SUTE AAa d►-`� LuMnnho Q o a, wxnucrcR swu M.Lvdn AccEss Ar RaoRF,mts PavnmgM mnrklc Ohm ahauld bo Worq unhirkh•tvrploctmxa Im wm mm—d for aong De%vberry Engineers Irk. Y'iH nonR .rAVLr 'ynosTox.uAc7q nroxc 00.•"0x0 m,raaa+o MYSOLS ON TYPICAL APPLICATIONS 1 oruwH ar: ecu R RNPcT 1 Cdald7>E83(e): '� /�w•`kb CMmlan BS: BBA UNE MOM^.,�R. _. i<geean MIOaECr HwBEa 30003923 Ge4mapy M URUtt M-.MERK j1` JCB lanl®OC 9CD,09,3 1gLUC5: L-.'W.R. .,•T .� POLE Ia: A'^:100 R. •�'' aR'WYbaN BM:ICC R. I `04�•A•u ,#2231-84 •`_ I CDOROINATF3: "a tm M TA3£6N-a mRNL'Ll4 ipA I �.1� attgIWMNC TAPFA ILNaTII OT TIE FalfrCp ! °--°0°RAw "v.TACtE cxN uGwc aF)arm N 42' 40' 37.42" cgoes oN 1rwSu AaRuwlex aaeaoc cr W 71' 07' 51.50" THE MU1C0 2m9 mmfRA (H)Rl14WEEA5 MA11M FROM i1R MA55 00r tI +i ars Gr rsRu waSAE ovrwxm cx o,/,z/,2 '1 1 L xEA4'cSr STREEn B.LNpxs,aa4 TURNPIKE STREET N. ANDOVER, AAA 01845 sxEEr TmE LT4TIONARY DIVIDED CLOSURE 2 TRAFFIC MANAGEMENT PLAN EW—m LE-5 222 GREAT POND RD, NORTH ANDOVER, MA 01845 X NORTH ANDOVER MA SC03 w W W J Hudson®� Ds11yn 6m�pue® �mcccc�:n: vr.�nsm nr rtrn�s� CHECKED BY: ,M YR APPROVED BY: DPH SUBMfiTALS 1 aY. W[ T991p1 R iSb 0 /ID/ID OotR W 'JI[WIR' NORTH ANDOVER 1 3, MA SC03 � g 323 GREAT POND RD NORTH ANDOVER.NA 01843 sacs mtc 1rs3' KEY PLAN � KEY PLAN. 1 I SCAE;N.T.S l—N APPROXI"'M LAT: N4Z 41'10.74 COORDDNTEM LONG: W71'08'Da.10' N(I�: LEASE EXH= F_ MME' S OF F INE FJDSTMC THIS LEASE PLAN IS OUGRkMMATIG M NAME AND m STAME ro SUPPORT AMCTHPROPOSED EM IS MiENDED TO PRONDE GENERAL RtFORAAITION = HAS NOT BEEN COMPLETED BY HUDSON DESIGN RIMMING THE LOCATION AND SIZE OF THE X GROUP.LLC.DR*MGS ARE SUBJECT TOCHANGE GE PROPOSED WIRELESS COMMUM nON FACILRY. THE PENDING OUTCOME OF A STRUCTURAL ANALYSIS. SITE LAYOUT WILL BE FINALIZED UPON COMPLETION W OF SITE SURVEY AND FACILM DESIGN- W APPRO)OMATE IAT. N42'41'10.74' Q COORDINATES LANG w7r o8'oR.fo' W J dw— TOP-F PROPosED ANTENNAVnD. ®� ,�G n 168•-0'f(+1L5y PROPOSED LESSEE(1) ' ANTENNA 15.10 X 24.z'H EEEV.�38'-0't(CGU ��c°a".rn''Dx.s.re«arc ,e rmwery 183'-0•t(AMSL) PROPOSED CUSTOM MOUNT TOP OF FIMFO UT1IfY POLE LGN-6.3(AMSQ ra EXISTING GUY WIRE('TYP.) 1 ryC ry •.,: PROPOSED INFATHEtHFAD + �I PROPOSED POWER FROM « b EMSTNG UTILITY POLE /NO 1872PROPOSED FIBER .+ COSTING UTUTY POLE EX6TING UTILITY POLE NO 1872 w UNMARKED .• '++ r .o• * �, A Y :R PROPOSED ROS CONDUT TO METF7t PROPOSED(1)1/2'COOL Q M 2•CONDUIT FROM RIOR CHECKED BY: J% 70 AMENNA I R APPROVED BY-. OPH •i PROPOSED FIBER IN PROPOSED FIBER DEMARC BY 2'U-GUARD DlSTNC UTILITY POLE ( RBQt PROWDElR O IS'AGL UNMARKED SUBMITTALS PROPOSED FIBER «Dt oR m PROPOSED AC/DC CONVERTER (FRONnW&&BACKHAUL) PROPOSED LESSEE PROPOSED RGS CONOUT (1)AWS RRH PROPOSED LESSEE BOA FUSED PROPOSED SAR-0 OISCONNE'CF&SURGE ARRESTOR PROPOSED LESSEE METER o /s/m ma Door a NORTH ANDOVER MA SC03 $� A S'TO 81-8' N ACCORDANCE WITH 1>rz 122 CI&A7 POND RD UOUIREDE1d�el1TS NORM ANDOVER.MA 01543 N -+ ELEV. 0'-O"f ACL "Ln l:• L� 5�ll^a=1�1�'- -_;,,6.� sxm tln6 129'-D=_(AMSC) ELEVATION & PHOTO p, PROPOSED GROUND ROD ELEVATIpNt RAP{11-e e,c !�NuoouR zz.3a scM a 5/B-I'-0 L-x EXISTING PHOTO DETAIL 2 L-2 11x17 SCALE 1/16'1'-0' - SCALE N.T.S L-2 LEASE EXHIBIT yOg; F- THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND AN ANALYSIS OF THE CAPACITY OF THE EXISTING PROPOSED LESSEE(1) In IS INTENDED TO PROVIDE GENERAL INFORMATION STRUCTURE TO SUPPORT THE PROPOSED LOADING ANTENNA 15'°:s24.21N = REGARDING THE LOCATION AND SIZE OF THE HAS NOT BEEN COMPLETED BY HUDSON DESIGN PROPOSED WIRELESS COMMUNICATION FACILITY. THE GROUP.LLC.DRAWINGS ARE SUBJECT TO CHANGE. PROPOSED LESSEE X SITE LAYOUT WILL BE FINALIZED UPON COMPLETION PENDING OUTCOME OF A STRUCTURAL ANALYSIS. OF SITE SURVEY AND FACILITY DESIGN. �1 _ (1)AWS RRH L I Lu DOSTING UTILITY POLE °CY B UNMARKED W 1 J Hudson®® PROPOSED OVERHEAD r- D�aICls GrwwA® WIRES BELOW �I unacoo°:sm nassmxe.:-rtnn nsysss r^ r GREAT p0 D R� �1 4' `\\ 14 5Y `1s'1� • L' - �_ p RRH DETAIL PLAN a o s GRAPHIC SCALP a FST s x 22.54 SCALE: 1`-1•-D l-3 j� 11.17 SCALE:1/z'-T'-O" R � PROPOSED ANTENNA D I•�` 1 PROPOSED LE.(1) W. CHECKED BY: JX ANTENNA 14.1'0%24311 --VO SECONDARY r N APPROVED BY: DPN —FleER SUBMITTALS FIBER FRONiHAUL CRD. &BACKHAUL 0.t MII K:arnl M s ` *� I' � � I �r N� w 'y _ PROPOSED CUSTOM `N 'aie ANTENNA WITHOUT GPS - �F/�/ MouNT NORTH ANDOVER ac/Dc coNvERTER MA SC03 ` ( I � me waxsas: Y'"MrI 60A.SERVICE 222 CREAT POND RD 7/e'-f♦THREADED EOUIPAIETR NORTH ANDOVER.MA 01845. SND FOR ANTENNA I I ETOSIDLG lfITlM POLE 7— _ MOUNTING UNMARKED i MT WASHER I I H LOCK WASHER RADA UNIT sMtt�� SMALL CELL awrENNA oMEMSIONs 471 T1 Wxs D ^N EQUIPMENT DETAILS DDNENSIDNS•15.1-ft24.2' 7/8'-9 Hrx NUT WEIGHT,55 L85 WEIGHT:22 LOS METER SOCKET ` ss¢r uV eTn ANTENNA MOUNTING - ANTENNA DETAII�i RADIO DETAIL 2 DETAIL J GENERAL WIRING DIAGRAM 4 L-3 SCALE N.T.S L, SCALE:N.T.S L-3 SCALE;N.T.S L-O SCALE N.T.S L� plelyl=1-J6714EVA Hudson 0 H . AM ` ". fid' v LAKE COCHICHEWICK M gi NORTI-T `'�� , rl or•csro usarc ANDOVER MSIIN.U11LITY PIUC COUNTRY x,m�OT1lIIv Not r: nq CLUB >.. -.rroacxlu ireseE'aan VMWED Ta cxlsnNe pppp e 5 �✓Y, Or to Rml .' � ® l� IMM EXHIBIT . 1. AN ANALYSIS OF THE CAPACITY OF THE EIOSTING TIES LEASE PLAN IS DIAGRAMMATIC IN NATURE AND m STRUCTURE TO SUPPORT THE PROPOSED LOADING IS INTENDED 10 PROVIDE GENERAL INFORMATION HAS NOT BEEN COMPLEIED BY HUDSON DESIGN RESARDINC THE LOCATION AND 512E OF THE x GROUP.I.I.C.DRAWINGS ARE SUBJECT TO CHANCE PROPOSED WIRELESS COMMUNICATION E7stlLRY. THE PENDING OUTCOME OF A STRUCTURAL ANALYSIS. SITE LAYOUT WILL BE FINALIZED UPON COMPLETION W OF SITE SURVEY AND FACILITY DESIGN. W 2 ANTE D MOANINGS OF FINAL PROVIDED 70 ANDINE ANTENNA MOUNT 70 BE PROVIDED W ENGINEER 0 �_Po�ANTENNA OF RECORD PRIOR 70 CONSTRUCTION. �p UB; N42 47'30S' W �•ELEV 3169"i-_B6.tCMANA7ES: LONG W71.OS'24.4' J $r_DF PBOPX1- AHTEP1Hi --`_ PROPOSED EX 4�•H Hudson® ELEY.'38`6' V.GL) ANTENNA ISA*0DdlDS G70upxa®� 180'-6•t(AfISJ PROPOSED CUSTOM MOUNT it PROPOSED 3'-O'H FIBERGLASS t~ aacm M EXTENSION muw:s•xxu:mum xL:+Zi sxs n' EXISTING PRIMARY uWVXr.wo•w w:Psgale,:a., TOP OF IXISTING UTLM POLE POWER ELEV.=3a-p 3 ACL) E f E EXISTING SECONDARY 176'-O•-(�E E- E '�++...�,_� POWER - I IXI 41'PB M�RY„ EXISTING UTILITY POLE p1659 _ E. fOXiSDNC EXISTING SECONDARY CABL'''��r� PROPOSED WFATNERHFlD POWER "'+. ISTNG ELC j----E E E-L7 EXISTING" �P�ZN OF.VASsgn EXISTING CABLE QZ\ A EL P. EXISTING FIBER o. M' EXISTING TELCO CIV rPROPOSED 0.4 EXISTINGISTING UTILITY POLE1659PROPOSED(1)1/2•COAXPROPOSED FIGS CONDUIT TO METALRN 2•CONDUIT EROM RRH CHECKED BYJXTO ANTENNA FIBER IN l"�R`T�ED EM DPN PROPOSED FIBER DEMARC BY 2•U-GUARD FIBER PROVIDER O 15'ACL SUBMITTALS PROPOSED AC/DC CONVERTER PROPOSED FIBER (FRONMAM&BACKHAUL) _ I f. PROPOSED FIGS CONDUIT PROPOSED LESSEE (1)AWS RRN PROPOSED LESSEE BOA FUSED PROPOSED SAR-O DISCONNECT&SURGE ARRESTOR PROPOSED LESSEE METER A aYTU15 IDAE Iffi IR N ANDOVER SC05 ih*fir a. MA 5'TO IF-6•(AGL) 511E AOEI�s IN ACCORDANCE WITH UTILITY COMPANY ? 678-666 GREAT POND RD. REOUREMENIS NORTH ANDOVER.MA 01845 li�GROUND SHOTflltt ELL'/. 0'-0"t(ACL) lam �_ 1az'-o•e(AMSC) y =-IL�11. ELEVATION & PHOTO PROPOSED GROUND ROD _ ELEVATION t q Y�Yom• e^.�'�5-a• e'-o• �_^ 22.34 SCALE 3/e"�r-o L-z EXISTING PHOTO DETAIL z L 11.17 SCALE:3/16'1'-0• SCALE N.7S l-2 1 rACr EXHIBIT F THIS LEASE PLAN IS PRDIAGRAMMATIC IN NATURE AND 1, AN ANALYSIS OF THE CAPACITY OF THE EXISTING IS INTENDED TO OVIDE GENERAL INFORMATION STRUCTURE TO SUPPORT THE PROPOSED LOADING REGARDING THE LOCATION AND SIZE OF THE HAS NOT BEEN COMPLETED BY HUDSON DESIGN tf PROPOSED WIRELESS COMMUNICATION FACILITY. THE GROUP,U.C.DRAWINGS ARE SUBJECT TO CHANCE X SITE LAYOUT WILL BE FINALIZED UPON COMPLETION PENDING OUTCOME OF A STRUCTURAL ANALYSIS. O / LL OF SITE SURVEY AND FACDJTY DESIGN. 4 W 2. SHOP DRAWINGS OF FINAL.EXTENSION ANDQ ANTENNA MOUNT TO BE PROVIDED TO ENGINEER QpC� OF RECORD PRIOR TO CONSTRUCTION. W PROPOSEwr FIBERGLASS SEXTENSION Hudson®® VTPl9.v:elH ___ ew�ws.wee:arc:aa ry:na.asm gn 6' PROPOSED LESSEE(1) •,� / ANTENNA 1S'Ou24.214 A EX:S'INO OVERHEAD�d' PROPOSED LESSEE M".RES BELOW (1)AWS RRH 15.1.0 V Z GRAPHI C C AI F RRH DETAIL iL PLAN L� �s } 2 3 FEET ggpo 11x17 SCALE: 1/2•=1•-0•`J t1j�F '/iS '+ PROPOSED ANTENNA I� izu CHECKED BY: JX 4 PROPOSED SECONCAR:' Lti ANTENNA(1) N APPROVED BY: DPH 15.1.44,2'14 —�FtBER SUBMITTALS FIBER FRONTHAUL CRD. ou[ t V j &BACKHAUL 1:. SAR-0 U♦i '__-_� MMC-MNf-NEP ca o al/iT/alwa mla! _ O MOUNTING KIT 3, aalI� SITU NMIFi ANTENNA WITHOUT GPS L y" J ; N ANDOVER SCO5 d r!j Ac/Dc CONVERTER MA PROPOSED 60A SERVICE 678-686 GREAT PO.V➢.R➢. 7/e•-16 THREADED FIBERGLASS EQUIPMENT NORTH ANDOVER.MA 01845 STUD FOR ANTENNA POLE-NP 8 MOUNTING EXTENSION y N FLAT WASHER «� vl¢r vrUt SMALL CELL CANTENNA LOCK WASHER RADIO UNE x' DIMENSIONS:3711xi11YxG'D EQUIPMENT DETAILS DIMENSIONS:15.1•Px24.2- 7/8'-9.HEX NUT WEIGHT..SS LBS WEIGHT:22 LBS METER SOCKET 91EliT xlA'BER ANTENNA MOUNTING r ANTENNA DETAIL �+�. RADIO DETAIL 2 DETAIL / 3, GENERAL WIRING DIAGRAM L�3 SCALE N.T.S L-3 SCALE:N.TS L-3 SCALE:N.T.S L-3 SCALE:N.T.S �L-3 692 GREAT POND RD, NORTH ANDOVER, MA 01845 x N ANDOVER SC06 MA W rn a LAKE W HudsonJ DCOCHICHEWICK p uwesoanrtte� nswG9w7er.ycen �a P.qm� nur�cva.wmus .rnrn aura �p`ZN OF Bryn AN m P, yG - M CI -' 0.47 0 NORTH y ANDOVER �L Inil- • mmmm 0Y: a CLUB APPROVED 99- DaN rpTl SUBMITTALS a Oona e .0 N ANDOVER SCOS MA M M GMT POND RD NORM ANDOVER,Mh 01645 mar Neu 1csY KEY PLAN 4.1 KEY PLAN t mmw�e 333 SCAIE NT,S L-1 APPRO7(M/7E IAT. X42'ti' G OOOAGRNTE3 IDNYl71'cw 14.Y 1g1F; i cAcc rnra,r 1- 1. AN ANALYSIS OF 7HE CAPACDY OF THE EXISTING THIS LEASE PLAN 15 DIAGRAMMATIC IN NATURE AND m STRUCTURE TO SUPPORr THE PROPOSED LOADING IS INTENDO TO PROVIDE.GENERAL INFORMATION = HAS MOT BEEN COMPLETED BY HUDSON DESIGN REGARDING 7HE LOCATION AND.SIZE OF THE k GROUP.LLC.DRAWINGS ARE SUBJECT TO CHANGE PROPOSED TIRELESS COMMUNICAION FACILITY THE PENDING OUTCOME OF A STRUCTURAL ANALYSIS. SITE LAYOUT WILL BE FINALIZED UPON COMPLETION W OF SITE SURVEY AND FACILITY DESIGN. W 2 SHOP DRAWINGS OF FINAL PROVIDED To ANO/OR OR ANTENNA MOM TD 8E FRONDED TO ENGINEER � OF RECORD PRIOR ID CONSTRUCTION. APPROXBIATE W. N47 41'42.8• Q• COOROINA7E5: LANG: W71.OS 14.r .I Hudson TOP OF PROPOSED ANTENNA P `• 4 �. Y k"'�'2"�" � � PT•'i�e—� 2DY-6•f(MISw -4'F, :y a',y.,• Ai, ,t. + 1 IDEv.�3o-B 3 •; 20,•_9•i T PROPOSED LESSEE(1) PROPOSED WEATHERHEAD ANTE"15.1'0%242'H TOP OF EXISTING IlTR7tY POLE PROPOSED CUSTOM MOUNT ELEV.s 26—D t AGL ya �' JT 20D'-0•f(AMSC) .� • - EXISTING GUY WIRE Vy / --� ���`� ExsnNc umm POLE EwsnHc UTILITY POLE S MECO 1669-5 - MECO 1669-5 PROPOSED POWER FROM PROPOSED FIBER FROM - '�• M IMEDNG UTILITY POLE EX6TIlG URLRY POLE /MECO 1689 ACROSS STREET /MECO 1686 ACROSS 51REEr G. 4 PYA f: , 0.4 7 0 PROPOSED RGS CONDUIT TO METER PIN ROPOSED 1 +4 dtECNra W. m UIT FROM RRH TO ANTENNA j n •m PROPOSED FIBER M APPROVED BY: DPH PROPOSED FIBER DEMARC BY 2•U--GUARD ' 3? ;I FIBER PRONDm 0 IV AGL a SUBMITTALS PROPOSED FIBER PROPOSED Ac/DO CONVERTER Al AM eEi o,m.m+ er (FRONII,AUL a B/Z%NFiAUL) 1"..-., PROPOSED RGS CONDUIT - PROSED OS RRH� "T' } w PROPOSED LESSEE BOA FUSED — DISCONNECT R SURGE ARRESTOR SAR—ORESfOR 1 PROPOSED LESSEE METER Q 1 N ANDO OVEERR ASCO6 a 7 MA S'TO 8'-6•(ACL) y�AooAax MUrUrr ACCORDANCE WITH AW ROM 922 CREXT POND R.NA D E RBOIIRENTS SS it 0 2 GROUND LEVEL sm 1,OL �ELU.2 D'-D"f(ACU 171'-0't(AMSL) t ELEVATON & PHOTO M2, 0-1— tir PROPOSED GROUND ROD GRAP141C SCALE 9vz1 wAmu ELEVATION t _ e ��'x-r 5-P g-9• EXISTING PHOTO DETAIL 2 L_2 ,,.34 SCALE 3/8".1'-0' l-2 11:17 SCALE 3/16'-1'-0• SCALE:N.TS L-2 LEASE EYNIRrr THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND 1. AN ANALYSIS OF THE CAPACITY OF THE EIMIMG _m IS INTENDED TO PROVIDE GENERAL INFORMATION STRUCTURE TO SUPPORT THE PROPOSED LOADING t2� REGARDING THE LOCATION AND SIZE OF THE HAS N0T BEEN COMPLETED Elf HUDSON DESIGN ovD PROPOSED WIRflESS COMMUNICATION FACILITY. THE GROUP.LLC.DRAWINGS ARE SUBJECT TO CHANGE Q W SITE LAYOUT WILL BE FINALIZED UPON COMPLETION PENDING OUTCOME OF A STRUCTURAL ANALYSIS. �•¢�AS OF SITE SURVEY AND FACILITY DESIGN. 2. SHOP DRAWINGS OF FINAL EXTENSION ARD/OR W ANTENNA MOUNT TO BE PROVIDED TO ENGINEER (j) OF RECORD PRIOR TO CONSTRUCTION. EXISTING UTILITY POLE G #MECO 669-5 ui Hudson PROPOSED LESSEE(1) ANTENNA 15'ex24.2 H PROPOSED LESSEE t�M1-53 (1)AWS RRH • r 21 �u�E 75.1'0 -n RRH DETAIL PLAN 4 .; rt M SCAI 2FEET N 22x34 SCALE 7'-D' • 11.17 SCALE: 1/Y=i'-o' `yt N,CF S S>`+j I`ANIEL P.�cyG� tJ' PROPOSED ANTENNA �L- o.<1740' f a 3f 0 CHECKED BY: Jx ip PROPOSED SECONDARY —••— e LESSEE ANTENNA i) �-IF --�N APPROVED.BY: DPH ' I 15.1'OIQ4.2HFIBER SUBMITTALS 'f � FIBERCRO. .Iq &BAAa[ I n � I/ - [ SAR- COMMSCOPE ��MC-MNT-TOPoMOUMMG KITANTENNA WITHOUT GPsf NN ANDOVER SC05 6- o AIAA E692 GREAT POND R7/e'-14 THREADED �SEMG UTILITY ENORTH ANDOVER.MA 01845STUD FOR ANTENNA MOU FLAT WAGFIAT WASHEt �a fSMALL CELL CANTENNA LOCK WASHER RADIO UNIT �v�iDIMENSIONS-37Hx111Vx6'DEQUIPMENT DEFAILS 7/9'-9 NIX NUT WEIGHT:SS LBST SMELT MMlSDt ANTENNA MOUNTING - ANTENNA DETAIL 1 RAD1%0 : DETAIL DETAIL GENERAL WIRING DIAGRAM 5 L-3 SCALE:N,T,S L-1 SCALIO N.T.S L-3 SCALE N.T. l-3 SCALE:N.T.S L-3 u -- ANrEw MouvtEo - Cc41NO U[lu fi POLE t - , * G< . , PROPOSU)LESSE1,RFN MOuNiCO 10 L%IR Nf• «` ''} ' a "'"' )"LUY POLI, 4, r ✓ \ E7fIS11NC UULIIY FULE-+""�'"��� \_ 40 qr4 " .; � �,. �-•�,�,,,rY�_ " >_ '"� "' t - 0000 Ml „„ oa ' dNORTH �ANDOVER t OMA SC07 sn 920 CAUT POND RD. I a ,.him,i X11 TDP OF IXISTiNG Ui1Lf1Y POLE �—[ E � 1nlC FYTHIPR \—( AN ANALYSIS OF THE CAPACITY OF TIME EXISTING THIS LEASE PMN 6 DNGRANMATIC IN NATURE AND m ELEV,m I8D'-±(AGM) 4—E E STRUCTURE TO SUPPORT THE PROPOSED LOADIN IS DREImED TO PROME GENERAL INFORMATION IBD'-0"±(AMSC) cr_e E HAS NOT BEEN COMPLETED BY HUDSON DESIGN REGARDING THE LOCATION AND SIZE OF 7HE X GROUP,UC.OPAWINTS ARE SUBJBCf TD CHANGE PROPOSED WIRELESS COMMUNICATION FACILITY. TME EXISTING PENDING OUTCOME OF A STRI1CRIRAL ANALYSIS SITE LAYOUF WILL BE FWILIZED UPON COMPLEMN LLI TOP OF PROPOSER ANTENNA PRIMARY POWER OF SITE SURVEY AND FACILITY DESIGN. W EEV..32-4 3 _ 177'-43(ANSL) PROPOSED LES517<(1) Q �G 0 P ANTENNA 15.1'0 X 243'H APPR070YA7E TAT. M47 42'01.9' ui �E1EY.�331-43 PROPOSED CUSTOM CDOf�NAT}S LONG: VV7T 04''TO"Y' JHudson® 17r-4'±(AMW MOUNT T1 E [ E� DMIQI16lOW c®® I4L b,GM pMf EXISTING 2y .— wstena�oenl:na»a rc�+,tl srsa PROPOSED wEATHEOHEAD71 SECONTWf1'POWER � �,1' 1 - n�waver,waet T+r:Ptl XulSb EXISTING FIBER j f7ISTING TELCO �T-T —r—r 1 " r�EXISTING FIBER PROPOSED(1)1/Y CM IN 2'CONDUIT FROM.RRH TO ANTENNA _hr * PROPOSED FIBER IN 2' �i I CONDUIT !f n .1 Y I EXISTING UTIun POLE T� #29-125/1706 F PROPOSED.RIS CONDUIT TO 13 :A METER 'V, IY{o •� I-II ij " PROPOSE FlMR PROPOSED AO/DC CONVERTER- (PRONTHAUL a BuaauuL) C1kECNEO W. PROPOSED LESSEE APPROVED BY: DPH PROPOSED FIGS CDNOUEr (1)Aws m SUBMITTALS PROPOSED LESSEE BOA FUSED ARRESTOR PROPOSED SAR-0 En ort[ oeomXml m DISCONNECT R SURGE ARRESTOR I I PROPOSED 1E55EE MEIQL Q 8 d o mewls tor¢oleo s 9 0 me NN1s = NORTH ANDOVER S'TO 0'-0'(AGI,) MA SC07 07 ACODRDWC WITH UTILITY COMPANY " `` YII[A0011p9 REQUIR 34M 1 r ti 920 GREAT POND RD. ExisrrNc 41 - NORTH ANDOMA 01005 1UO--CONDUITT, VER"�L,� e,L W LEVEL±(AGM) r- x+ »r ..,i" � G z T.4 m..µ"4' ,.-i.^.,� s¢v lots 145'-0•t N I I—I �-1-.i'" L--Ir I_i I —I t_ s 1 t Itt N x' (AMSU -�I Iii ,,i,- y 1=" I� - ELEVATION do PHOTO PROPOSER I—al 19, L -] GROUND ROD ' a�T N19!>M! GPAPHIG SCALE ELEVATION e 4 1c �FET EXISTING PHOTO DETAIL 22.34 a SCSCAMM: -2 1/2•.1'-O• L-2 --- 11x17 St/4'-1'-0' SC/1E:N7.5 L-2 LCA<P PYNIRR HIM* THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND AN ANALYSIS OF THE CAPACITY OF THE COSTING m IS INTENDED 70 PROVIDE GENERAL INFORMATION STRUCTURE TO SUPPORT THE PROPOSED LOADING REGARDING THE LOCATION AND SIZE OF THE HAS NOT BEEN COMPLETED BY HUDSON DESIGN PROPOSED LESSEE PROPOSED WIRDESS COMMUNICATION FACILITY. THE GROUP.U.C.DRAWINGS ARE SUBIECT TO CHANGE (1)ANS RRM W SITE LAYOUT WILL BE FINALIZED UPON COMPLRNN PENDING OUTCOME OF A SIRUCRIRAL ANALYSIS. OF SITE SURVEY AND FACILITY DESIGN. LJ.I IXSTNG UTILITY POLE U) 1129-125/1706 Q LLI - �Exlsrllx PROPOSED LESSEE(1) E���yANTENNA,5.f'D X DodanG up 24211 QDoftQn G,oupueOV'RHEAD 1Y esCGO�osRY. MIRES BELCW �O` YRnYG`lps �: b.: TY I✓'N izEr • r 4.53' 15.1'e Y` i -r o RRH DETAIL PLAN 4 o s r.RAaHr.S,:j F y TAT u g� 22x34 SCALE: 1'.1""" L-3 F 11x17 SCALE 1/2"=1'-o- p R. PROPOSED AMENNA PROPOSED LESSEE(1) 4` ANTENNA 15.14 X 24.21L f I R CHECKED BY. JX NSECONDARY APPROVED BY: DPH FSER FIBERJ-NGRD. SUBMITTALS &BA •I'R prt oto m SAR-PROPOSED CusmMOUNT 5 r..ANTENNA WTIHOUr GPs I[z { y NORTH ANDOVER AMA SC07 EME920 ANDOGREATVER. POND 01 7/8'-14 THREADED �t � II II i EQUIPMENT NORTH ANDOVER.MA 01845 $ STUD FOR ANTE"MDUNnNO n FLAT WASHER I I I I SMALL CELL CANTIO,NA LOCK WASHER DIMENSIONS:15.1'0.242' 7/B'-9 HEX NUT RADIO UNIT I EQUIPMENT DETAILS WEIGHT.22 LBS DIMENSIONS:37'H.11'MSc6'D I I IEXI57NG U111ltt POLE WEIGHT:55 LBS I J29-125/1706 METER SOCKET sHcn xwgcA ANTENNA MOUNTING �_� ANTENNA DETAIL �� RADIO DETAIL r L, DETAtL 3 GENERAL WIRING DIAGRAM s SCALE:N.T.S L-3 SCALE N.T.S L-1-1 SCALE:N.Ts L-3 SCALE:N.T.S L-3 38-112 SALEM ST NORTH ANDOVER MA 81845 z N. ANDOVER MA SC09 W W N a W J Du 6Hudson umarocauae em�uuerrnns�4mi a�msm •uo0vee wdx5 :Ma4w•aa (�cC�ac�m Br: .uc APP ems+ B1: DPN SUBMITTALS In t4L �� q 0 4/4/1f IW[� J 9R WNt N. ANDOVER MA SC09 30-112 SALEM ST N.ANDOVER Diel 0184S am TU use' KEY PLAN smr wane 1X KEY PLAN t SCALE N.T.S L-t APPR0XWM LAX. NQ AO'58.9 R COORDNAIM LCM Y7r W 2790 H TOP OF PROPOSED ANTENNA fJm, IrAGP FXHIRrT F1EV..32-8 t AN MW.Y515 OF THE CAPACTY OF Tiff E7�IWC THIS LEASE PIAN IS DMGRANMATTC W NATURE AND m 245'-8't(ALISL) INFORMATMIN KOS NOTBEENCOMPLETED BY HUDSON DESIGN REGA IMG THE IS DMININE070�N MID�OF THE _ GROUP,LUT.DRAWINGS ARE SUBJECT TO CHANGE PROPOSED WINDLESS COM IMC01ION FACTUM TIfE PENDING OUTCOME OF A STRUCTURAL ANALYSE. SITE LAYOUT WILL BE FIRRUCED UPON COMPLETION W ELF/.:231__Dmf PROPOSED %z4.2•H OF SITE SURVEY AND pICRlTT DESIGN. N PROPOSED CUSTOM //� MOUNT APPROI4MATE LAM N47 40'SIM' W TOP OF E%ISRNC UTIL.ifY'POLE/ COORDINATES: LANOZ W'/T•09'2T,g0' J ELEV. 30'-0'i(AGC) 243'-0"!(AMSL) Hudson � C PROPOSED(1)1/2'COAX W RRH 2'CONDUIT Will FROM PROPOSED POWER MGM-,-- TO MITINNA ei �.urcn ace,er.:sa POLE 013M EXISTING GUY WIRE PROPOSED WFATHERWAD PROPOSED FIBER FROM -_: POLE#1380 EXISTING PRIMARYL'MOM POWER MECO MECO#1 80-1U`nUTPOLE QUO PROPOSED RGS CONDUIT TO METER j. CABLE UTILITY CABLE PROPOSED FIBER W 2' CONDUR * S- n * EXISTING GUY WIRE 1 PROPOSED FIBER DDAMC o FIBER PROVIDER O 15'AGIL PROPOSED AG/DC CONVERTER (FRONIHAUL&BACIOUIUU i c-iir-�srf RCHECKED BY: PROPOSED RGS CONDUIT ::)•.I;.P S]:,ic+; ' APPROVED BV: DPH PROPOSED I-6M F115ED i (i)AW ED SEE lilt SUBMITTALS DISCONAIM a SURGE ARRESTOR Q aloe p�p11 W PROPOSED LEa^SFE METER p g �l 9 A NryAYm IED Iwc Drat A Se[1u1R] s'M B'-B'(AM -~^ -= - I- N. ANDOVER MA ACCORDANCE WITH LITSCOJ W LDY COMPANY N L REQUIREMENTS J8-112 SALEM ST ANDOVER MA,OIIMS EIEV. 0-0'. im ' l X�T ITLIR y ,, ELEVATION & PHOTO I PROPOSED caTDIDID RDD - arm palmar GRAPHIC ELEVATION �r•y yi..p• El(IST(NG PHOTO DETAIL 2 L-2 29x34 SCALE:3/B'�1'-0" L-2 SCA E:KT.S L-2 11x17 SCALE S/18'�T'-0' LEASE EXHIPIT THIS LEASE PLAN 13 DIAGRAMMATIC IN NATURE AND AN ANALYSIS OF THE CAPACITY OF THE EXITING m IS INTENDED TO PROVIDE GENERAL INFORMATION STRUCTURE TO SUPPORT THE PROPOSED LOADING E%STING 2' REGARDING THE LOCATION AND SIZE OF THE HAS NOT BEEN COMPLETED BY HUDSON DESIGN - X PROPOSED WIRELESS COMMUNICATION FACILITY. THE GROUP,U.C. ONG SPE C.DRAWINGS ARE SUBJECT TO CHANGE W SITE LAYOUT WILL BE FINALIZED UPON COMPLETION PENDING OUTCOME OF A STRUCTURAL ANALYSIS. OF SITE SURVEY AND FACILITY DESIGN. PROPOSED LESSEE W (1)AWS RRH N EXISTING S PROPOSED LESSEE(1) j><9'-2'HT ANTENNA 15.1'OEX 21.2'H a CXISTINT Ul,l EXISTING 4'x12'-2'HT Q'� J U-CONDUR \ "' = Hudson -- Ex+smc�T:uTY POLE Dn1¢,crollp�® E%STING(2) EDGE OF 1/7,bxB'-10-HT CONCUR PAYSMBNT r--C' �OSnNG OVERI!EAD I -) WIRES BE:OW PROPOSED LESSEE(,) _ efIENNA 1S1'e X 2x211 • � 1�434�' GRAPHIC SCAN G LF11Tj RRH DETAIL PLAN 4 D 3 1 x S TEE7 ?x 22.34 SCALE:1'-1'-0' L-3 3 N 11.17 SCALE 1/2`e+'-O' • l+1 PROPOSED ANTENNA +AyL CHECKED BY: JX 0 SECONDARY i k APPROVED BY: DPM FIBER SUBMITTALS PROPOSED CUSTOM FIBER FRONTMAUL- CRD. MOUNT h BACKHAUL Ct btE CCpmRp N • i 0 SAR'- 'u 1 tit u� t I i os o imRyu tort Mla rdm ti ANTENNA WITHOUT GPS N. ANDOVER MA AC/DC CONVERTER SCDB /7 I yl I I I I I I I I GOA SERVICE o 313-112Aooruc ST 7/8'-14 THREADED I EDUIPMFM N.ANDOVER NA,01843 SND FOR ANTENNA ' I I I BITING UTILITY POLE !G MOUNTING FLAT WASHER �a LOCK WASHER �� siaT rlu SMALL '0.24.2 RADa uuR EQUIPMIENT DETAILS DIMENSfO22 13.1'0:242' 7/8'-9 HEX NUT pTUpNSfONS:37�h1i'11'x6'D METER SOCKET WEIGHL.22 LBS WEICHi:33 LBS _ SMLr raomFn ANTENNA MOUNTING ^ ANTENNA DETAIL + RADIO DETAIL 2 DETAIL 3 GENERAL WIRING DIAGRAM �1 L_3 SCALE N.T.S L-3 SCALE SCALE;N.TS L-3 SCALE:N.TS V 1. A l i f' V 4{ I" n IN4 1I ,rl lu IIII.111 1011 1 Ilf � !• ra�'I GcsF1 RuH IQ Ilk l aCQT-r'arr�Q •Y��l A_�4 yQg: 'EASE EXHIBIT F_ AN ANALYSIS OF THE CAPACITY OF THE DOSTING THIS LEASE PIAN IS DIAGRAMMATIC IN NATURE AND m STRUCTURE TO SUPPORT THE PROPOSED LOADING IS ILTDIDFD TO PROVD;E GENERAL INF'ORWOION NAS NOT BEEN COMPLETED BY HUDSON DESIGN RECARDING 111E LOOAnOM AND SRE OF THE 70P OF PROPOSED ANTENNA GROUP,I.I.C.DRWMfGS ARE SUEULCT TO CHANGE PROPOSED MREI—COMMUMGIIDN FACILITY. TE PEND"OUTCOME OF A STRUCR1M ANALYSIS. SITE LAYOUT WILL BE FINALIZED UPON COMPLETION LU �C OF231'-0't(AMSL) OF SITE SURVEY AND FACRIIY DEIGN. LL1 �ElEV.�41�QOPROPOSED LESSEE(1) a 230'-0't(AMSC) ANTE"7&1'0 X 24.21H APPROLOIMTE IAT_ N47 40'44.1' TOP OF IXISRNG URUIY POLE PIROPOSED CUSTOM MOUttf COORDINATES LONG: 071"IDS SW LULU ELEY.=39-6± 229•-G"±(AMSC) � Hudson DO MG PRIMARY' l�dfiT+�;N� Yn Y•, r OE • POWER �IS R� 4• 2 ;gym�5 YlOOEG DS'fPi E E�E� � d ( er¢^.D+ctxaecsm ..Ar-m.� r[uICOVV.M.ctan -:+fi awv. EXISTING CROSS ARIA-" EXISTING UTILITY POLE MECO 1 403 EXISTING FIBER EXISTING FIBER s •'LQ u. w U .1� w' IX EI(ISTING SECOAT)4Rf POWER �_y,.r• A• q.� �.. I ! ..� Y ,�'Y G PROPOSED VANDIERHEID ;H EXISTING CABLEa; QCo ;1 EXISTING FIBER EXISTNC TELCO r_6 \_.,'•+' ,gLIE r 1 EXISTING TELCO 2 EXISTING TELCO �IX •' CHECKED BY. jx PROPOSED RGS CONDUIT ID ME.iDt IN PROPOSED(1)1/Y COAX ./ •'`" i ^° if� I 2'CONDWT FROM RRHPROPOSED � r APPROVED OP}! _DEMARC TO ANTENNA R PROVIDER - ABROVIDER O 1IL PROPOSED OBER IN '• } SUBMfTTALS PROPOSED FIER 'A PROPOSED Ac/Dc CONW]RIDR (FIRONnuuL ESE 8aCg11d1U PROPOSED RCS CONDUIT PROPOSED LESSEE EXISTINGIlfiLftt POLE 91 (1)AWS RRH MECO 1403 - PROPOSED LESSEE 8OA FUSED PROPOSED SUR-0 DISCONNECT&SURGE ARRESTOR PROPOSED LESSEE METER 0 0 m/D/13 los FABI O EXISTING 24x3o SIGN N ANDOVER SCt 1 � MA 0 STD B'�'(AUY) gIS ADO IN ACCORDANCE MIH COMPANY _ RIM REQUIREMENTS 313 SUER A NORM ANDOVER. S 01985 N 0 AIGROUND LEVEL aOa 1TfIL 114Y ELEV. 0'-0"3(pCl) 189'-0'±(ANSI) iL ELEVATION & PHOTO PROPOSED GROUND ROD CALE ELEVATION e 4 Y 9'GRAPHr-e"+r s4" -0 q r, 9 22.37 SCALL 3/1'`1'-0" l-2 EXISTING PHOTO DETAIL 2 -2 77:17 SCALE 3/tfi�1'-0' SCLC NTS l-2 I FACF EXHIBIT THIS VASE PLN IS DIAGRAMMATIC IN NATURE AND AN ANALYSIS OF THE CAPACITY OF THE EXISTING m IS INTENDED TO PROVIDE GENERAL INFORMATION STRUCTURE TO SUPPORT THE PROPOSED LOADING "ISTING OVERHEAD EXISTING URUTY POLE REGARDING THE LOCATION AND SIZE OF THE PROPOSED WIRELESS COMMUNICATION FACILITY. THE GROUNOT BEEN DRAWINGS ARE�EUECT HUDSON OD INCE q,\ X HAS WIRES BELOW 1'MECO ;4C3 SITE LAYOUT WILL BE FlNAU2TED UPON COMPLETION PENDING OUTCOME OF A STRUCTURAL ANALYSIS. y PROPOSED LESSEE(1) Lu OF SRT SURVEY AND FACILITY DESIGN. � ANTEMA 15'ox242?L W PROPOSED LESSEE (n �\ �` (1)�RRTR J Hudson \b� 1mlmmcaorr.rr •s 9`� _ 1M52 RRH DETAIL PLAN 4 GRAFtW SAF fEi't X 22134 SCALE:1'-7'-0' L-3 1} 11.17 SCALE: 1/2'=i'-D' PROPOSED LESSEE(1) R ANTENNA 75.1'0 X 24.2'8 • PROPOSED ANTENNA CHECXED BY: JX SECONDARY APPROVED BY: DPH u FIBER SUBMITTALS FIBER FRONIHAULISOCKU GRD. Ma [atlmxul rn 4 BACKHAUL � Q I SAR-DPROPOSED CUSTOM NJ MOUNTANTENNA WITHOUT GPS N ANDOVER SC)1 Ac/Dc coNVMA 6OA SERVICE 313 SALEM 5T THREMEp EQUIPNEH7 nroRTH aVDOVER,MA OTB05 -%ISYING UiIUIY POLEMOOUNTIINGTUD R ANRMFN ,✓/MECO 1403FIAT WASHER LOCKWISPIER RADIO UNRSMALL CELL CANTENNA DIMENSXNRS:3YH:11-ftSD EQUIPMENT DETAILS DIMENSIONS 15.1bx2kr 7/0'-9 HEX NUT WEIGHT:55 LBS WEICM:22 LBS MLT 91Ri NUIBFP. ANTENNA MOUNTING ANTENNA DETAIL �� RADIO DETAIL i�� DETAIL 3 GENERAL WIRING DIAGRAM LSVQ SCALE:N.TS L-3 SCALE:N.T.S \L-3/ SCALE N.LS L-3 SCALE:N.T,S L-3 � . RARIMI M;I I so wil IL 190 M M Wl liL I mielyf4fiRlsi f •North Andover Ay 'f C%ISTMCCO]0�111ILI0-tt@�FDIC ,y-1 ROCgtE�D UIILIfV ,. r AMENNA:NOU,ATO uCPOLC_ r �Ur�u11Pf'DSED_LESSfaRR`I, 110 IIIID.TD 1D1VSNO ,IYP9LY C. . r ins �Pw "r ,�. IdOrw NORTH ANDOVER SC12 MA .0 .' <r Nom: RFya'eXLARTT F" AN ANALYSIS OF THE CAPACITY OF THE EOSSTHG THIS LEASE PIAN 5 DIAGRAMMATIC IN NATURE AND m STRUCTURE 70 SUPPORT THE PROPOSED LOADING IS INTENDED TO PRm=GENERAL 6NfU1aIAnoN s NO HOT BEEN COMPLETED BY HUDSON DESIGN REGARDING THE LOCA71ON AND SM OF THE X GROUP.LLL DRAWINGS ARE SUBJECT 70 CHANGE PROPOSED WIRELESS ODMMUNOCATION FACMY. THE PENDING OUTCOME OF A STRUCTURAL ANALYSIS. SITE LAYOUT WILL BE FIK4L9 D UPON COMPLETION W OF SITE SURVEY AND FACILITY DESIGK Lu 1 APPROXIMATE W. N42 1 V 495' a 'COCRp IMATE LANG: N4Z OS'41.8' < J Huds 1af� ® uxn-uaunrn TOP OF PROPOSED ANTENNA _ I �• 9 •t( U ____ PROPOSLESSEE(1) N IXISRNCE PROPOSED ANTENNAy CiWIRE, '--0- ANTENNA 15.10 . x 24.2'H 228'-0't(AMSC) PROPOSED CUSTOM MOUNT' 3 s roP'OF EXISTING LNRLRY EL L-1. SO-8 f AG F PROPOSED POWER M EXISTING UTILITY POLE •1 ^'� t - A4 224'-6"t(AMSC) MECO 3970-16 ` -•p ACROSS THE STREET PROPOSED FIBER FROM /+C `.Y' T - 3" yS, �,` t'x".•. DOSTING UTILITY POLE MECO 3970-16 s° PROPOSED WEATHER-EAD ACROSS THE STREET EXISTING GUY WIRE EXISTNG GUY WIRE I P+� EXISTING Unlet POLE #MECO 3970-tM4 L� PROPOSED RGS CONDUIT 7O METER PROPOSED(1) 1/2'COAX IN 2"CONWR FROM RRHI �N:FECiRED BY: JX * TO ANTENNA Y 1 PROPOSED PBFR APPROVED BY: DPH PROPOSED FIBER OFYARC 1W 2'U-GUARD IX6TINC INTutt POLE y n0ER.PMIIDFR O 15'AGL .MECO 397D-84 SUBMITTALS o PROPOSED F13M PROPOSED AC/DC CON10M (FRONTHAUL&BACKHAW PROPOSED LESSEE PROPOSED ROG CONDUIT (1)AWS RRH PROPOSED LESSEE SOA FUSED PRCPOSED SAR-O DISCONNECT&SURGE ARRESTOR PROPOSED LESS4Ti METER ...,. , lR4>p� E NORTH ANDOVER o SC12 MA 5'TO 8•-C ylg AMR= Irf COMPANY s"a.; 124-1513 DILE ST. N� .:�. NORTH ANDOVER.MA 0180.5 REOURtF7AF1NI5 41 GROUND 51Ydf 11" ELEV. 0'-0'3 AGL "L1 11 GJ1c c. I.:y �r 194'-0'b(AIASL) 51 3 J,- -' - ELEVATION & PHOTO aL PROPOSED GROUND ROD ' ELEVATION i GRAS SCALE 2217 SCALE:3/8"-r-o' L-z EXISTING PHOTO DETAIL2 G 111117 SCALE S/16•-1'-0' SCALE N.T.S L-2 LEASE EXHIBIT ,HIS LEASE PIAN IS DIAGRAMMATIC IN NATURE AND AN ANALYSIS OF THE CAPACITY OF THE EXISTING m IS INTENDED TO PROVIDE GENERAL INFORMATION STRUCTURE TO SUPPORT THE PROPOSED LOADING REGARDING THE LOCATION AND SIZE OF THE HAS NOT BEEN COMPLETED BY HUDSON DESIGN PROPOSED WIREI COMMUNICATION FACILITY. THE GROUP.U.C.DRAWINGS ARE SUBJECT TO CHANGE SITE LAYOUT WILL BE FINALIZED UPON COMPLETION PENDING OUTCOME OF A STRUCTURAL ANALYSIS W OF SITE SURVEY AND FACILITY DESIGN.. PROPOSED LESSEE(1) LLI ANTENNA 15'0.242'11 a UJ EIOSTING UTILITY POLE J MECO 3970-84 p--�-, Hudson �..0; Dost4R G'+OUPuc®® 111H.a.DmM.1:1M0 m2�m�ssssss EXISTING OVERHEAD PROLESSEE YAR-S BELOW t i POSED ' t d (1)AWS TMH a 14752* GRAPHIC SCALE i _• }$ RRH DETAIL PLAN 4 D .S1 2 s TIF N 22k34 SCALE- 11.17 CALE,1.17 SCALE 1/2'-1'-0' PROPOSED ANTENNA ' PROPOSED LESSEE(1) CHECKED BY: JX g}� ANTENNA 15.1'0 X 24.2'11 u SECONDARY APPROVED BY: DPH ) -i FIB ER d I r SUSMFITALS FBERCKHAUL UL t; CRD. W SAR_ Li ILJ p Li I F c o RV>e+mat Ioesl R ±aj HWC C", ANTENNA wTHouT GPs 'tT t mom CUSTOM NORTH ANDOVER OL l� AC/DC CONVERTER SC12 MA 1 s:c.IPa1sz GOA SERVICE '0 124-158 DALE ST. r� 7/8'-14 THREADED ( EQUIPMENT NORTH ANDOVER.MA DIM 3 SND FOR ANTENNA I I EXG TING UDL.TTY POLE _ MOUNTING I(( i MECO 3970-84 FLAT WASHER u g SMALL CELL CANiENNA LOCK WASHER RADIO UNIT aMENSIONs 37'EL111Y 6 D EQUIPMENT DETAILS DWENSIONS: 15.1'0.242' 7/8'-9 HEX NUT WEIGHT:55 LBS VIEIOHT:=IBS METER SOCKET srtR AAiEP ANTENNA MOUNTING ANTENSCALE:NNS DETAIL L13 RsAAD1ODETAIL L23 SGLEANT.S l}3 sGLEERAs>MR7NGDIAGRAM L-3 PHR GxI511NC UpL17Y POLE 378.....'. .ir .. ..,� .•��.•`�• FROPOSI'p l4',5CE 'a�«- ti'; .. AMENNA MbUN1Lp YD a y A . Ex,nuGunLrrY POLE ' eximNc uliurY FOLE � ,. R Po+oPOScp LE.'$EE ftRl1—/�� d•�' �+uuHrm>n rxu-rwc + uriiJrY POLE "* r �wm k" 5 y ", ANDOVERN. : K ANDOVER Mk 51845e362-SM SALEM ST TA 1 Nom, IC SE EXHIBIT (� TOP OF1. PROPOSED ANTENNA ELEY.' 8'3(AtISU SNNCNR 7700 SUPPORT THHE�OPOSEDLMOINGGG INTENDED PLO64 IS DIAGRAMMATIC IN MURE AND TO PROVIDE GENERAL INEDRMgtOM 2 RAS NOT BEEN COMPLETED BY HUDSON DESIGN REGARDING1HE LOCATION APO SIZE OF THE X GROUP.LLL MVA ARE SUBJECT TO CHANGE PROPOSED WIRELESS COMMUNIMMM FACILITY. THE PENDING OUTCOME OF A STRUCTURAL ANALYSIS SITE LAYOUT WILL BE FNAL�D UPON COMPLEION W F PROPOSED LESSEE(1) OF SITE SURVEY AND FACaM DESIGN. W Elc'V. S7-B'3(AGI,I ANTENNA 15.1'0%24211 2 SHOP DRAWINGS OF FNA_EXTENSION AND/OR •-6.3(AL15L) RECORDPRIOR PMOUNro BEC NS HU�CTIICK tO ENOAEER OF 'Q APPROplM7E LAh N47 40'32.30 W P 0 EXISTING L(-L) POLE COORDI1N71S TONG: W r O5'43" � J ELEV.a -0•.(ACL) J,� 23303•-0'3(AMSL) Hudson fthGm yam,^E PROPOSED(1) 1/2'COO PROPOSED POWER FROM---- N 2'CONDUIT FROM RRH i,, JW Ya '+•M TO ANTENNA ;"` Ar Ty .q�„, acc o�oasnlfl POLE 02378 1 I�l,= 1►,k1R" yt,n. j"�Y� a.'L.:T xsm vegan ='u- PC WEITHFAHFM .I _ •� r'( U•NAt ! .71, ` i, a.,co+r.w mN.s N•'ttm. E tIr lR EXISTING NOOSE IXSRNC GUY WIRE •' '!j} a (± •Cl �� POWER LINE Ow fDOSTINIS HOUSE PROPOSED FIBER' BER FROM--- 'V~ POLE/237 `^ CABLE WIRE 4J� •N CSO OPOSED FIBER N 2' PROPOSED RMCONDUR TOCI' ,. ExsnNc unuTY #. ' Si SII MEEK EXISTING UTILITY POLE�(— CAB o. Z 0 MECO.#2378-1 �G PROPOSED FIBER DEMARC Bt 'i FIBER PROVIDER O 15'AGL. PROPOSED FIBER PROPOSED AC/DC CONVERTER I (FRONMMX&aAc*Aly CHECKED BY.- ix oosrNc anon POLE , ' PROPOSED RCS CONDOR MECO X2378-1 1 v APPROVED BY•. DPN PROPOSED LESSEE BOA FUSED (1) PROPOSED D !1 �+ •: t r'� � a SUBMITTALS DISCONNMT a SURGE ARRESTOR ^'4':N'1`'� Gml aQ ILoolnrW W PROPOSED LESSEE METER p a m/LI/GS IED IDR DxR x N. ANDOVER MA V TOIN ACCORDANCE�WITH $4 +�:' i SC13 RE�OUREDUPS� 11 _ -••, ' M.ANDOVER VISI DIM � I>• � 'L" r1 GROUND tEVEI T1nI5 . ELEv. - AcU I — I 4--II ' 203'-0't(AMSL) I r-I ❑I�' � I 5 y H3' ELEVATION & PHOTO i t G s PROPOSED GROUND ROD 9T6T IaIfQ EVATION GR�R+IG EL t -0' EXISTING PHOTO DETAIL 21 L-2 11X17 SCALE:N.T.S L-2 11x17 SCALE.3/18'-1'—O' tFAeF EXHIBIT NOTES F THIS LEASE PLAN IS DIAGRAMMATIC IN MATURE AND t,AN ANALYSIS OF THE CAPACITY OF THE EXISTING m IS INTENDED TO PROVIDE GENERAL INFORMATION STRUCTURE TO SUPPORT THE PROPOSED LOADING REGARDING THE LOCATION AND SIZE OF THE HAS NOT BEEN COMPLETED BY FNDSON DESIGN PROPOSED WIRELESS COMMUNICATION FACILNY. THE GROUP,LLC,DRAWINGS ARE SUBJECT TO CHANGE SITE LAYOUT WILL BE FINALIZED UPON COMPLEUON PENDING OUTCOME OF LU A STRUCTURAL ANALYSIS. OF SITE SURVEY AND FACILITY LESSEEY DESIGN. (1)AWS RRH 2. SHOP DRAWINGS OF FINAL EXTENSION AND/OR LU ENNA ANTMOUNT TO BE PROVIDED TO ENGINEER OF RECORD PRIOR TO CONSTRUCTION. PROPOSED LESSEE(1) ANTENNA 15.1'0 X 24.2 W Hudson® - EXISTING UTILITY. POLE T)cilQA C o-P e®. nacammm o n:mal_cava 17' �-.-... EXISTING LOIN HEAD L,A WIR:S BELO"+ 15.1.0 t 2 GRAPHIC SCM F Ua RRH DETAIL PLAN 4 P s 1 2 z CETT ` 111��1 22x34 SCALE: 1"-1'-O' L-3 Qt' d + 11.17 SCALE: t/2'-1'-D• p "+AVI_L P. G • PROPOSED ANTENNA rl 10 PTiOPOSm rECKED BY. _ JX L LESSEE(1) o SECCNDAR`! .( ANTENNA N APPROVED BY: DPH I 15.1'Ox24.2H FIBERSUBMITTALS 4' &9BACKROANMauL caD, xA c+c rsmw rn SAR- C� MGMMSCOPE J MC-MNE-TDP Li T MOUNTING KIT p � ANTENNA WITHOUT GPS it+ {N N. ANDOVER MA 41 O AC/DC CONVERTER SC13 SOAlrc.auus: EOU E 362-53D SALEM ST 7/8'-14 THREADED •1 EQUIPMENTMENTI & N.ANDOVER Mil 01845 J��ESND FOR ANTENNA #237- UTILITY RILE STUD FOR /2378-t FLAT WASHER o I sxrz'r 1� LOCK WASHER "^ suALL CELT_C^JNT`-""A RADIO UNIT EQUIPMENT DETAILS DIMENSIONS:1S1'Ox243- 7/8•-I HOC NUT DIMENSIONS:37'HX1/'wx6'D WtIGHE:22 t85 WEIGIfR 55 LBS METER SOCKET _ sRi Hu1.8ER ANTENNA MOUNTING �_� ANTENNA DETAIL Lt3 RADIO DETAIL L23 DETAILS SCALE.L33 GENERAL SIRING DIAGRAM L-53 208-418 DALE ST. NORTH ANDOVER, MA 01845 x N ANDOVER SC14 MA W LL ry J Hudson � 4 ¢ex tgx:�en umG�u]:fISaR.`.V SI:f'�2:=y'.,,••v o,s.i tin ry'y,us2lp lK. OF ASm v ANLL P. 1A CI A770 !r - r/ CHECKED BY: r J APPROVED BY- UB rTTALS Y-UBMfTTALS � • oVtw Amar N ANDOVER SC14 MA 1oc A1DR6S 208-415 OPLE ST. T10R1i1 ANDOVER,W MM 44T TSII£ 3'Y14.53' �c _..._. _.. KEY PLAN =y41 �Z 1naTnmmm 33 KEY PLAN t 1 SCALE:N.T.S L-1 APPROXIMATE UM! N4Y 40'!- i 4. COORDItNhS: LONA W71'OV 20 NOTES, tract EXHIBIT 1.AN ANALYSIS OF THE CAPACITY OF THE EXISTING THIS LEASE PLAN IS WSRAMMAMIC IN NATURE AND m STRUCTURE TO SUPPORT THE PROPOSED LOADMD IS INTENDED TO PROVIDE GENERAL INF'ORMAHON HAS NOT BEEN CONPIEIEO BY HUDSON DESIGN REGARDING TINE LOCATION AND SM OF 7HE X GROUP,LLL.DRAWINGS ARE SUBJECT TO CHANGE PROPOSED WIREl COMMUNIOMX FACILITY. THE PENDING OUTCOME OF A STRUCIIMAL ANALYSE SITE LAYOUT Will.BE FINALIZED UPON COMPLETION W TOP OF PROPOSED ANTENNA OF SITE SURVEY AND FACUTY DESIGN. W 4 - 2. SHOP DRAWINGS OF FRUL EXTENSION AND/OR 228'-8 f(AMSC) ANTENNA MOUNT TO BE PROVIDED TO ENGINEER OF Q RECORD PRIOR TSI CONSTRUCTION. CF PROPILSFD AFl7EHIK__ PROPOSED LESSEE(1) APPP0DtD41TE LAT. N4T 40'54.4' W ELlV.2 40-6'3(/CGU COORDINATTS: LANK W71'Or 29.4' (1JJSLa ANT(NNA 15.1'A X 242'H Hugon 00212n rroupm * PROPOSED 5•—o'H FmFRGULLS of EXTENSION r�, �L, e�b�AP011fEI E%157ING PRIMARY ica•om.vrt�o �'� TOP OF IXISTING UMITY POLE POWER ELEV.�34-D t ACL 221'-0'3(ANSL) _ sf i�. E �� C E E � •^�y h EXISTING UTILITY POLE MECO§1426 EXISTING SECONDARY ,* - PROPOSED WEOTIIETEHEAD POWERR +� . E OF EXI . p AN EL P. STING CABLE GJ, M `- EXISTING FIBER CI - :H2 EXISTING FIBER 0.4 7ZQ � - Q, CS I m EXISTING TELCO - $ PROPOSED RGS CONDUIT TO METER PROPOSED(1)1/2'COAX �," IN Y CONOIRT FROM RRH LITE I� CHECKED NT: JX �+ TO ANIM'M -f. '.. APPROVED BY: OWE PROPOSED FIBER IN _ � �I. PROPOSED FIBER D 15' U-UARD A C FIBER PROVIDER O 1s'AGI.L �• , SUBMITTALS PROPOSED AC/DC CONVERTER PROPOSED FIBER(FRONMAUi'A vcE alsnwa rt PROPOSED EL eAclwAUL,) PROPOSED RGS CONOIJIT PROPOSED (t)AMS RRH .. PROPOSED LES 60A FUSEDPROPOSED SAR-O DISCONNECT'h SURGE ARRESTOR I' PROPOSED L103FE METER � I 1 o mMN In¢t� w zq N ANDOVER SC14 MA S'TO IN�CO 206-418 DALE ST. REOUQtEl.U74i5 q NORTH ANDOVER.MA DIM 3 41 0 �EELEV. LEVER(AGC) RM 157'-O'3(AMSC) ELEVATION &. PHOTO PROPOSED GROUND ROD GRAPHIC 5fiLE - a1¢T A1Aev ELEVATION e P-4'x'-e' s'-e e'-o• L-� 22n34 SCALE-3/ -D' L-z EXISTING PHOTO DETAIL 2 G 1107 SCALE 3/15".V-0' SCALE:N.T.S L-2 F41 SF�HIBIT NGI6: F- IM IM LEASE PLAN IS WGRAMMATIC IN NATURE AND 1.AN ANALYSIS OF THE CAPACITY OF THE E)USnNG m IS INTENDED TO PROVIDE GENERAL NFORMATCN STRUCTURE TO SUPPORT THE PROPOSED LOADING PROPOSED 5'-0'H REGARDING THE LOCATION AND SITE OF THE HAS NOT BEEN COMPLETED BY HUDSON DESIGN FlBERGLA55 EXTENSION PROPOSED WIRELESS COMMUNICATION FACRJTY. THE GROUP,LLC,DRAWINGS ARE SUBJECT TO CHANCE X SITE LAYOUT WILL BE FINALIZED UPON COMPLEnDN PENDING OUTCOME OF A STRUCTURAL ANALYSIS W OF SITE SURVEY AND FACILITY DESIGN. PROPOSED LESSEE(1) 2. SHOP DRAWINGS OF FINAL EXTENSION AND/OR ANTENNA 1S'ft24.211 W ANTENNA MOUNT TO BE PROVIDED TO ENGINEER OF RECORD PRIOR TO CONSTRUCTION. PROPOSED LESSEE (1)AWS RRH �v42 J t V f w\ O w Hudson ®. w Du3Tf \w w- r4Rir,'V11 L••-,L.Q NW�`M..vw Sfvf EXISTING OVERHEAD % 1YRES FLOW 4 . 1�475S 15.1'm RRH DETAIL PLAN * q� 1 z FEET 22ftJ4 SCALE: 1"�1'-0' l-3 11.17 SCALE:1/2"e1'-O' .rf OF r'14, �` � `ate'• ?.F NL„u S. • PROPOSED ANTENNA I 1 CI - ` ! CHECKED BY: Jx ! LESSEE(1) 'a SECONDARY N APPROVED BY: ANTENNA(1DPH 15.1'044,27H 'FIBER SUBMITTALS . FIBER FRONTHAUL GRD. &BACKHAUL En' m SAR-O i� (� COMMSCOPE 5 MC-MNT-IOP o u Inu uemf t l f O MOUNTING KR arc Niue ANTENNA WITHOUT GPS ;:�"� N N ANDOVER SC 14 d _ AC/DC CONVERTER MA � 9fE 4DCIfL4 PROPOSED BOA 5?11,CE o 2DB-418 CALF ST. r�L 7/8--14 THREADED Yt _------FIBERGLASS LIP ENT NORTH ANDOVER,MA D7845 3 SND FOR ANTENNA POLE-TDP _ MOUNTING EXTENSION S 1 FIAT WASHER o I sf[cr trnt LOCK WASHER RADIO UNIT A^ SMALL CELL CANNA DIMENSIONS:37TL01Wx6ro EQUIPMENT DETAILS DIMENSIONS: 15.1'#x24.V 7/8'-9 HEX NUT WEIGHT:55 LBS WEIGHT:22 LBS METER SOCKET SNEET 1fLVBLP ANTENNA MOUNTING - ANTENNA DETAIL RADIO DETAIL z DETAIL GENERAL WIRING DIAGRAM L_3 SCALE:N.TS l-3 SCALE N.T.S L-3 SCALE:N.TS L-3� SCALE:N.T,S `-J 521 -623 DALE STREET, NORTH ANDOVER, MA 01845 x N ANDOVER SC15 MA W N F` J dson D.19.Gfoup.. Ilh:wID1MA0CH0 lL�SS1.1131f1 w:1p6 1 0 y�2 AMEL P. yG //ycl Co.4 7 0 /ONPS CHECKED BY: JX APPROVED BY: DPH SUBMITTALS Q ioc mrt oaoslo+ m no TmM/n fax ms o N ANDOVER SC15 r MA " st2•od¢as, 521-623 DALE STREET NORM ANDOVER IM 01845 Yui " ro.:. s11m lmc KEY PLAN /1d5Y 11 K� 7 7 \\\N HEY PLAN 1 SCALE N.TS L-1 APPROocDU17E IAT. N47 41 0&Z' COORDINATES: IDNC: Vail 04'49.5' tl� 1 rL EX01®IT 1.AN ANALYSIS OF THE CAPACITY OF THE EXISTING THIS LEASE PIAN Is ova AMLNATC IN NATURE AND m SIRUCIUHE TO SUPPORT THE PROPOSED LOADING IS IAENDED TD PROVIDE GENERAL NFORMATION HAS NOr BEN COMPLETED BY HUDSON DESIGN REGARDING THE LOCATION ANO SIZE OF THE X PE OUICOME�OFF A STRGS ARE UU13JECT TO CRHRN.ANAL SRREE IA�YO FTNALQm UPON COWIkTiOtHE W OF SHE SURVEY AND FACILITY DESIGN. W 2 SHOP fXHAW1NC5 OF FINAL gr7r ON AND/OR ANTENNA MOUNT TO BE PROVIDED TD F]1GRlEETt OF RECORD PRIOR TD COWSIRUCRON. AFPROXIMAIE LAT: N47 41'OTR' Q COOROhBATES LONG: WPr OW 49.5• .W.f �T'OP w PRDT+osm ANTENNA Hudson 272-0 t yF r-0-* FS9EE Eif�LA'1ENNA-_ PROPOSED L (1) •ort ,t;a'Y , _+G." t r; � F1EV._23'-C}(AMS* ANTENNA 15.1•*X 24.2'H Fes} �j IMARY PO.YER rc N>X azm i PROPOSED S'-0•H FIBERGLASS ExtENSION u i . s E E E 3 Y s TOP OF OOSTiNG URLRY POLE ' 224'-6't(AMSL) EXiSf1NG PRM/•A1'POWER "L y�' /� •+ ,,.+ PROPOSED WEATHERHEAD SnNG SECONDARY POWER A p�`t{OF 4f4, EX STING CUY WIRE l�. EXIS NG CABLE .� Q2�� ANIEL P '# Lt: EXISTING FIBER • ycl x -EXISTING TELCO 0 $', Q PROPOSED ROS CONDUIT TO METER PROPOSED(1)1/2-COAX ON Gj CONDUIT FROM RRH ♦ �•. }I CHECKED B'h—�� AE TO D ,r APPROVED BY. DPP —PROPOPOED SFIBER RN ... '^ '1 H PROPOSED FIBER DEMARC E1Y 2•U—GUARD IXISYING UTILf1Y POLE i FIBER PROVIDER O 15'AGL ECO 46O � Y SUBMITTALS PROPOSED FIBER Xa as °�' • PRorosm Ac/Dc cDNVERTER (FRDNTTHAUL x DrclOuuL) � � PROPOSED RGS CONDUIT PROPOSED LESSEE (1)AWS RRH PROPOSED LESSEE OOA FUSED _ PROPOSED SAR—O DISCONNECT R SURGE ARRESTOR PROPOSED LESSEE METIER a vpYn Nam n srrc mum N ANDOVER SC15 EXISTING URLRY POLE ME MA 5'TO fl•-8•(AI.'L,) MECO x 1410 M ACCORDANCE W71H Snf ADp� MREO IRFEDAIF?1I9 3 aW DALE ANDOVER.I 0 NORM 1845 0 ELEV.N_OOL3(ACL) 1 llT- ,o,y aa,m,mz 194'-0"3(AMSL) u I' � I- � Jx i ELEVATION & PHOTO PROPOSED GROUND ROD amxT rAn+eOt ELEVATION ZUM SCALE: e 3/ _t'.0- L-2 EXISTING PHOTO DETAIL_/21 ,1X17 SCALE'3/,6•_,'-p' SCALE,H.T.S L-2 tFMM F EXHIBIT NOTES THIS LEASE PLAN 5 DIAGRAMMATIC IN NATURE AND 1.AN ANALYSIS OF THE CAPACITY OF THE DOSTBIG m IS INTENDED TO PROVIDE GENERAL INFORMATION STRUCTURE TO SUPPORT THE PROPOSED LOADING REGARDING THE LOCA71ON AND SIZE MPLETED BY HUDSON DESIGN PROPOSED WIRELESS COMMUNICATION DFACILM. THE GROUF IKE HAS�LL.DRAWL NG SUBJECT TO CHANCE �S X. SITE LAYOUT WILL BE FINAUZED UPON COMPLETION PENDING OUTCOME OF A STRUCTURAL ANALYSIS Off' x OF SITE SURVEY AND FACILITY DESIGN. IUj 2. SHOP DRAWINGS OF FINAL DaENSION AND/OR W ANTENNA MOUNT TO BE PROVIDED TO ENGINEER OF PROPOSED S'-0'H Ito RECORD PRIOR TO CONSTRUCTION. FIBERGLASS DRENSION Q J Hudson ,a EYWI N WIRES BELOW RH.EAD �` PROPOSED LESSEE(H ANTENNA 15'ax242'H PROPOSED LESSEE 0. (1)AWS FIRM `75.1'0 ' �, p a f.R4PHlf-GfAle RRH DETAIL PLAN �. FEEI Tix17 SCALE: i/2'=1'-0' OF 1,4S, a. API E_ P. s • 1I PROPOSED ANTENNA c. It i CHECKED BY; UK ;p Y PROPOSED W) H SECONDARY k AFRENNA APPROVED BY; D?H 15.1'0.24,2H RBER SUBMITTALS I FIBER FRONTHAUL GRD, m as m &BACKHAUL SAR-0 r COMMSCOPE S J MC-MNT-TOP oa o m/n/n IwifA� v MWNfING KIT � M ANTENNA WITHOUT GPS `.p. N ANDOV R SC15 AC/DC CONVERTER MA y PROPOSED 60A SERVICE 521-623 DALE STREET L 7/8'-14 THREADED �)A. FIBERGLASS EQUIPMENT NORTH ANDOVER MA 01845 FOR ANTENNA POLE-TOP ]� MOUNTING EKTENSION J N I J�jSIUD FLAT WASHER rt LOCK WASHER RADIO UNIT SMALL CELL CMTIENNA DIMENSIONS;37'Hxit'Wx6b EQUIPMENT DETAILS DIMENSIONS 15.1'0x24.2' 7/B'-9 HEX NUT WEIGHT;55 LBS WEIGHT:22 LBS METER SOCKET sarttr/AA16b! ANTENNA MOUNTING ANTENNA DETAIL RAD10 DETAIL 2 DETAIL �3� GENERAL WIRING DIAGRAM 5 �_3 SCALE:N.T.S l-3 SCALE:N.T.S L-3 SCALE:N.T.S SCALE N.T.S L-3 250-336 S. BRADFORD ST, NORTH ANDOVER, MA 01845 X NORTH ANDOVER SC16 MA W a Hudson �uvw:o.vniur,�o rc�:nrt�ss•sv a . w . Ir vo CNEmNm 87: JX APPROVED M DPM ' SUBMrrrALS r .1 •! � o /iymt tOfi mer d �y gg • �` - M� ♦ NORTH ANDOVER �. � SC16 MA S.BPADMRD NOM 250-M6ANDOVM MA 01545 KEY PLAN 14!53* �i �z an na�n X KEY PLAN 1 r SCALE N.T.S L-1 APPR AMM IAT: NAY R COORDMATM- IANO: N71' 28.01' • LEASE E n-fl AN ANALYSIS OF THE CAPACITY OF THE DaSTING THIS LEASE PIAN IS DIAGRAMMATIC IN NATURE AND m STRUCTURE TO SUPPORT THE PROPOSED LOADING IS INTENDED TO PROVIDE GENERAL INFORMATION HIS NOT BEEN CCMPLETED BY HUDSON DESIGN REGARDING THE LOCATION AND SIZE OF THE X GROUP.LAO.DRAWINGS ARE SUBJECT TO CHANGE PROPOSED WIRELESS COMMUNICATION FACILITY. THE PENDING OUTCOME OF A STRUCTURAL ANALYSIS SITE LAYOUT WILL BE FINALIZED UPON COMPLETION W j OF SITESURVEY AND FACILITY DESIGN. ILIA) cn APPROXIMATE ur N42 41'24.58- W �COORDINATES: LONl2 vr7r o4'2B.o1- AAAI Hudson 0. mm u.cmmrw.�scam ra.r..as.� TOP OF PROPOSED ANTENNA 187'-0•t(MISE) G eE(�OPOSLT ICmmmB____ PROPOSED LESSEE(1) — _F1EV.-31•-O•=(Af,U ANTENNA 15.1.0 X 242'N. IXRINC UiILRY POLE 188'-0•t(/MA) PROPOSED CUSR)M MOUNT MECO�S7 TOP OF EXISTING 1BUTILITY POLE ELEV.=I8- 2 A •� 4'-8.2 (AMSL) PROPOSED 1YFATIIERNFAD PROPOSED POWER FROM EXISTING UTILITY POLE MECO/SO LOCATED ACROSS THE STREET rl /-EXISTING UTILITY UNE RDSIIN INE t - 4 1 --,X6J1N,(iUii Ell; PROPOSED FIBER FROM 0337NO VMMJTY POLE \ MECO#30 LOCATED ACROSS THE SIREDEXISTING UTILITY LINE \ '; -'Y '.EXSTINC'UTIUIY LINE: EXISTING GUY MIRE PROPOSED(1)1/2-COAX IN 2- IXISTWC GVY,HIRE„ ; CHECKED BY: +A .N CONDUr FROM RAN TO ANTENNA PROPOSED RGS CONDUIT TO METER b N APPROVEDPROPOSED FIBER IN BY: DPH 0 2'U-GUARD PROPOSED FIBER DFMARC BY H FIBER PROVIDER o 15'ACL , SUBMITTALS 1q •i PROPOSED FIEFA PROPOSED AC/DC CONVERTER Ox o0T Art (FR6MHAUL t BACKHAUL) PROPOSED LESSEE PROPOSED RGS CONDUIT (1)AWS RRH �—EXISTING 3-0 z 3'-6•PIPE PROPOSED SAR-0 PROPOSED LESSEE 60A FUSED ° DISCOMiECT Y SURGE APRESTOR 4 0 O PROPOSED LESSEE MM /iVlel TOS MW s 6 _ sri wwe a EXISTING SIGNS ��� NORTH ANDOVER (TD BE RELOCATE - AS NEEDED) e'-a•(Ica) t�.�, a,•W SC16 MA N AOCORDANCE WITH UR UIRDJQlis COMPANY REQy ! 911E ACORM EXISTING UnUTY �I ) _ x ~ ! - NORTH ANDOVERBMA 01"S E MECO N 41 POL - 2 O � GROUND LE`/0. �+ .t T IT .i +s.1 t ELEV. 0'-O.2(AGUy1 � 1) L I r �` .,� 4. +1'. .; ,�A;•.°` 1MET 1}IIE t 55'-0•f(AMSu - ���� ELEVATION & PHOTO PROPOSED GROUND ROD ELEVATION LE EEi P -RAPN c e1F srczr xu� E xSCALAE:3 i'-4`Yi' Si' 8'-0' /e'-1•-D- L-2 EXISTING PHOTO DETAIL 2 L-2 11x17 SCALL 3/18'°1-• SCALL N.T.S L-2 IFASF FYHISIT THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND AN ANALYSIS OF THE CAPACITY OF THE D(ISTING - CO S INTENDED TO PROVIDE GENERAL INFORMATION -STRUCTURE TO SUPPORT THE PROPOSED LOADING \rte 7(IST.NC OVERHAD REGARDING THE LOCATION AND SIZE OF THE HAS NOT BEEN COMPLETED BY HUDSON DESIGN / PROP SED SED WIRELESS COMMUNICATION FACILITY. THE GROUP,U.C.LCDRAWINGS ARE SUBJECT TO CHANGE W:RES 3'LOW SITE UYOUT WILL BE FINALIZED UPON COMPLETION PENDING OUTCOME OF A STRUCNRAI ANALYSIS. W OF SITE SURVEY AND FACILITY DESIGN. `v PROPOSED LESSEE \ 9� Uj (1)AWS RRH EXISTING OVERHEAD U) VARES BELOW [_ W J PROPOSED LESSEE(1) /-EXISTING OYERHEAO Hudson ANTENNA 15'Ox24.2'N y� / V,7RES S�CW COACn G_pue® MMEOGSOTI#S1lilLftt POLE \b\' n xrni::,,°f„�:I.�s`0 i i:•¢ns%v d�v� \w •. Al \\\\ Ja 13YY Q, f q GRAPHIC ICA'F =z RRH DETAIL PLAN I�� 1 t 2 3 FEET 'S N 22x34.SCALE 1°-1'-0' f! 1107 SCALE: 1/2.-1.-0. � R • PROPOSED ANTENNA PROPOSED LESSEE(1) CHECKED BY: Ux ANTENNA 15.1'0%24.2'H z SECONDARY li APPRdrD BY: DPI( e IIP. FIBERFIB FRONTHAUL SUBMITTALS 2_ &BACKHAUAUL CRD. W[ e6aVtol i Q . SAR-O 1 �� N4 0 /t]%0 IGtt OCR d -� PROPOSED CUSTOM w srT Hvuc ANTENNA WITHOUT GPS -,;Z4 MOUNT NORTH ANDOVER a 1� 1 AC/DC CONVERTER SC16 UA I mL ADCRTSf L y SCA SUMCE 250-336 S BRADFORD Sr. 7/B'-14 THREADED p9/J EOUIPMEYT NORTH ANDOVER,MA 01845 SND FOR ANTENNA UTILTIY POLE MCUNTiFlG I I I MECO X31 a FLAT WASHER �d SMALL CELL CANTENNA LOCI(WASHER RADIO UNIT �� sxc 7P� DIMENSIONS 37'Hbn1'WxsD EOUIPMENT DETAILS DIMENSIONS 15.1'0x242' 7/B'-B HEX NUT WEIGHT:55 LBS WECHT:22 LBS METER SOCKET SIRET NWIDflI ANTENNA MOUNTING - ANTENNA DETAIL 1 RAD10 DETAIL � DETAIL �� GENERAL WIRING DIAGRAM s '/S� SCALE N.T.S l-3 SCALE N.T,S L-3 SCALE N.TS -� SCALE:N.T.S L-3 -3 700-850 DALE ST NORTH ANDOVER MA 01845 — N. ANDOVER MA SC17 W W a LU Hudson ANNIEL P. �G M CI goo..4 7 0 arfa®D er: IDPWWM evc DPH ad SUBMITTALS a ea mown a s¢W6 N. ANDOVER MA SC17 mcg MAM DALE Sr w.AWDDVM wti MO .ms mic KEY PLAN s � ..n wu� EY PLAN t LM: wr 0.11=.,c- L-1 aoonort EM =A- wrr 00 uom Nam, I nm EXHBa F 1.AN ANALYSIS OF THE CAPACITY OF THE E'70iRNG THIS LEASE PLAN IS DNGRNAAATIC IN NATURE AND m STRUCTURE TO SUPPORT THE PROPOSED LOADING IS INTENDED TO PROVIDE GENERAL INFORMKRON HA.S NOT BEEN COMPLETED BY HUDSON DESIGN REGARDING THE UICA71014 AND SUE OF THE X PENDING 0rU-=£A S,RU,,URAL ANALY... SITE FINALIZED UVRELESS UPPON OOMP TOE W OF SITE SURVEY AND FACILITY DESIGN. LLL AN SHOP DRAWINGS OF FINAL EXTENSION AND/OR ANTENNA RIO RT TO N TRCADED TD ENdNEER of Q RECORD PRIOR TO CONSTRUCTION. APPR070MA7E IAT: N42 41'27.10' W cooROTNATEs: l Lori: 1Y7r o4' wto• J TOP° PROPOSED P1^ +A Hudson - ELF/. 26-63= Oas06 GTK � PROPOSED LESSEE(1) r 4 �moxacoaen r<Pr»:n.su E1EY._18u51-62 ANTENNA 15.1'0 X 24.2•N �.... •#. N T• w �T * auro�on wii'u�a"" Pic l%1 v..ene (AMSL) f t TOP OF EXISTI ELEV.m 2a'–0'3 NG U(ADL)DLTIY POLE '� 7 184'-0.±(AMSC) 1 t PROPOSED POWER F=---__ POLE/4736 —e COSTING GUY WIRE PROPOSED WEATHI]tHEAD 1 EXISONG CUY , PROPOSED(1)1/2'004X r FIR POSED FIBER FROM i IN 2'CONDUR FROM RRI1 DI NG GUY Y E POLE 14726 ; TO ANTENNA 4c h k ,! 9G PROPOSEDRGS CONDUIT TO i PCMETER OEIDUIT FIBER IN 2' �I, cyq� �ti i` AN EL P. f 3i' �• ,� .° oM cl UTILITY PROPOSED FIBER DEMARC BY MECON14726-55 POLE •�,'[tW'" 0.4 7 Q IN FIBER PROVER O IS'AGL PROPOSED FIBER �DItlAIG 'oI ii PROPOSED AC/DC CONVERTER (FRONTHWL R BACIOIHTL) * CHECKED BY: Jtt ,I PROPOSED RGS CONDUIT E%ISRNG UTILITY POLE MECO_4726-55 PROVED BY-, DPH PROPOSED LESSEE PROPOS LESSEE BOA FUSED (1)AWS RRH SUBMITTALS DISCONNECT 6:SURGE ARRESTOR I ,mc a6 o�A>w a PROPOSED LESSEE METER O q p-0 m N. ANDOVER MA IN AW-e W r: _ y SC77 UTILITY OOMPANY REOU6tEA1FNi5 700-BSO DALE ST o_ �,• N ANDOVER MA.01645 k ^� GROUND LEVEL ' ELEV._o ro'3 AGIa "S I I-1 I CI I , I f 1=1 I l r r, slur itOa 6D-D f(AMSC) wafl iELEVATION & PHOTO GROUND ROD .. _� ... �-+ slat Nm14p! .QwHlC SCALE L-2 ELEVATION , q Y-4'7�-i• 5 ..0• EXISTING PHOTO DETAIL _12, 11.1722,Z4 SCALE-3/6'_1'–O' l-2 I� SCALE:KT-S l�-2 11x17 SCALE S/76•_1'-0' I EACF EXHIBIT NOS; F- THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND 1.AN ANALYSIS OF THE CAPACITY OF THE ECISRNG m IS INTENDED TO PROVIDE GENERAL INFORMATION STRUCTURE TO SUPPORT THE PROPOSED LOADING - REGARDING THE LOCATION AND SIZE OF THE HAS NOT KEN COMPLETED BY HUDSON DESIGN X PROPOSED WIRELESS COMMUNICATION FACILITY. THE GROUP.U.C.DRAWINGS ARE SUBJECT TO CHANGE SITE LAYOUT WILL BE FINALIZED UPON COMPLETION PENDING OUTCOME OF A STRUCTURAL ANALYSE. OF SITE SURVEY AND FACILITY DESIGN. PROPOSED LESSEE(1) LIJ 2. SHOP DRAWINGS OF FINAL EXTENSION AND/OR EXISTING UTILITY POLE ANTENNA 15.1'0 X 24.2'H W ANTENNA MOUNT TO BE PROVIDED TO ENGINEER OF ch RECORD PRIOR TO CONSTRUCTION. EDGE OF PAVEMENT Q I. LU EIfISTIVG OVERHEAD 1 WIRES BELOW U PROPOSED LEE Hudson » -- (1)AWS RRH TkMOIt�xLOVp�e® air-wx«rv+ F."PSG*-�egS'14::'art Yr tt l^r1F1:9 •<rnla.�m 0.—1 VALE ST. �I - ^' RRH DETAIL PLAN 4 r.RAPHI-<r.AtE S t 2 3 HET ` NACNE 22x34 SGVE: -_ NORTH itx17 SCALE: 1/2'=1'-0' 4 AN!EL P. y PROPOSED ANTENNA U CI`.'_ I:o.4 7c6 i Sslt2"u�L�•t' CHECKED BY: JX, NI PROPOSED N SECCNpA{i'! LESSEE(1) APPROVED BY: DPM S ANTENNA ,! 15.1'044.2wk SUBMITTALS FIBER FRONTHAUL GRD. @BACKHAUL � ¢x axL tt'L6xitl1 m 5! COMMSCOPE �a �mns Iu uaT 0— mc-{ MITT-TOP n� MOUNTING KB `A mE ANTENNA"BOUT CPS N. ANDOVER MA AC/DC CONVERTER SC17 �.. � 6OA SERVICE 7005-850 MALE ST 7/6'-14 THREADED +il EOUIPLIENT N.ANDOVER MA Dim SND FOR ANTENNA MOUNTING v FLAT WASHER Ex6NNG UTILITY POLE c n f SHALL CELL CANIENNA LOCK WASHER MECO 44726-SS NT T ;SE RADID�T EQUIPMENT DETAILS DIMENSIONS:15.1'0x24.2' 7/8'-9 NIX NUT DItAEN6NDNs:37rytx77'Wx6'D METER SOCKT_T WEIGHR 22 LBS WEIGHT:55 LBS SKET IuuBLF ANTENNA MOUNTING — ANTENNA DETAIL 1 RAD10 DETAIL 2 DETAIL GENERAL WIRING DIAGRAM 5 L-3 SCALE:N.TS L-3 SCALE:N.T.S L-7 SCALE:N.T.S `-� SCALE N.T.S l-3 1 Hudson �•,�� ",` 1 fi . - a �. +alb' •'"` �� , . — �-=;�- �G, f t. j AX + x 3 uuFosF,n EK40 U111.I1Y VyUMI:n x 1 I.nVD IxOV _+ t>�♦ ' h IIIfI IIY Ixpll! , t ,... a �•.1 4 r ~� .. _ OIA- NDI`DIDTPpF%Is11Nn Gk hm I _ r - h .r x' s 1 l NOTES: LEASE Emsfr 1.AN ANALYSIS OF THE CAPACITY OF THE EXISTING THIS LEASE PLAN IS DUGRAMMATTC IN NATURE AND m S111UCIIIRE TO SUPPORT THE PROPOSED LOADING IS INTENDED TO PROJNE METAL INFORMATION HAS NOT BEEN COMPLETED BY HUDSON DESIGN REGARDING THE LOCATION AND SIZE OF THE X GROUP.LLL DRAWINGS ARE SUBJECT TO CHANGE PROPOSED WIR&ESS COMMMCATION FACRTHE lIY. T PENDDlG OUTCOME OF A STRUCTURAL ANALYSIS. SITE LAYOUT WILL BE FINALIZED UPON COMPLETION IL NOP OF PROPOSED ANTENNA OF SITE SURVEY AND FACILITY DESIGN. UJI 2. SHOP 2DS'-8't VI SL) �— ANTENNA MOVANT'TO BE PROVIDED TD ENGIIFf AND/ORGS OF FINAL EXTENSION OF N �F OF-P _ PEDPo���(1) RECORD PRIOR TO CONSRtUCIION. ApPRO7OgATE UT_ N47 41'41A' W ELEV.-40'-0't(AGIJ ANhTJNA 18.1•A X 24.211 COORDINATES; LONG W71'04'023' J 2W-8't(AMSC) c�ls,.o� * E"TaqD 5-011 FlBEH61A95rg. unGiorpuen®s I e oamwG PmMARr aiwn�rrwV.aain � POWER E E E E TDP DF DGSTING U T PON£ EXRTINC PRIMARY ELEV.=34-D t ACL r POWER 19B'-0't(AMSL) II 4 � C UTILITY POLE NG 52 Dc szzz i �XrM'C SECONDARYIXISTRIG SECONDARY PROPOSED WETHERHEAD �WER POWER OF M.QS�cep '�•...,;,,..�•-"'-•-�.+, *,,n. ExanNO CABLE �= AN EL P. F EXISTING CABLE - ^^+.�,,,` IXKTING+FBER CI po.4 7 D Exisnwr FIBERi ,p EXISTING UTILITY POLE—,Nr 5222 � tQ(tIAL \ g PROPOSED RGS COLmUT 70 METER PROPOSED(1)1/2•COAX * IN SANT FROM RRH EXISTING U CONDUIT o> .y.t CH�Br 'w ,.1 APPROVED BY; PROPOSED FIBER IN $ - �' PROPOSED Flur eDDAARC BY 2'U- •§- "'', H' Y z:' SUBMITTALS FIBER PROMDER o 15'AUL i PROPOSED AC/DC CONVERTER (FRp�Fl&FIBER PROPOSED RGS.CONDUIT PROPOSED LFA L•. II (1)AWS RRH 1 PROPOSED LESSEE GOA FUSEDL__ PROPOSED SAR-0 DISCONNECT&SURGE ARRESTOR PROPOSED LESSEE METER h D ml1MD Lela mm >t f SITE NAS EXISTING CABINET N ANDOVER SCAB Fs MA 0 S'TO S'V(AGC) y LL ''.. - DrTE A� THACCORDANCE WITH _ RUSSM LN. UTILICf COMPANY - '1'� NORTH(ANDOVER.MA DIM REQUIREMENTSLL .p,�..--"'•"'*' ' GROUND LEVEL ELEV. m 0'-Df AGC) "�:.11l'-U-SL -il�l5�1'.i�fr 5 ,Z:' A a .9«• e 164'-0't(AMs0 ELEVATION & PHOTO PROPOSED GROUND ROD twm xuLrOL �-� G�.PwC«�� L-2 ELEVATION /_1 q 1'-t'7-0' s'-A' e'-o' _ - - . 22a3a SCALE 3/e'-1-0• L�z EXISTING PHOTO DETAIL �1 1107 SCALE 3/18•.1'-0• SCALE:KT.S L-2 LEASE rnnn __-- - - VIES: _ r-- THIS LEASE PUN IS DIAGRAMMATIC IN NATURE AND 1.AN ANALYSIS OF THE CAPACITY OF THE EXISTING (]] IS INTENDED TO PROMDE GENERAL INFORMATION STRUCTURE TO SUPPORT THE PROPOSED LOADING REGARDING THE LOCATION AND SIZE OF THE HAS NOT BEEN COMPLETED BY HUDSON DESIGN X PROPOSED WIRELESS COMMUNICATION FACILITY. THE GROUP,U.C.DRAWINGS ARE SUBJECT TO CHANGE SITE LAYOUT WILL BE FINALIZED UPON COMPLETION PENDING OUTCOME OF A STRUCTURAL ANALYSIS. OF SIE SURVEY AND FACILITY DESIGN. PROPOSED S'—OM Z W 2. SHOP DRAWINGS OF FINAL EXTENSION AND/OR FIBERGLASS EXTENSION uj ANTENNA MOUNT M BE PROVIDED TO ENGINEER OF E— RECORD PRIOR TO CONSTRUCf10N. PROPOSED LESSEE(1) W sQ ANTENNA 15'0x24.2H rnLLJ PROPOSED LESSEE a� J (t)AWS RRH ( r.p s T\ Hudson®� `9(ISTtNG OVERHEAD ���® WIRES BELOW �'""�xrtstcrn uCX s;. w,.rxo.u.aa.s rn�zela. DALE ST. Q75.t'a RRH DETAIL PLAN 4 s 6z.PHI c^SIF 3� I1 x34 SCALE: 1 2--1.— L-3 T� N 11%17 SCALE: i/2�-1'-0' y ri OF ,/Is, R /_ PROPOSED ANTENNA CIF CHECKED BY. Jx PROPOSED o SECONDARY LESSEE(I) N APPROVED BY., DPH A ANTENNA 75.1'ox24.2'HJZ: Fem SUBMITTALS U RBER ORD. 8 BACar. aNt ¢xmmx tx �'•'j SAR-0 '�S�COMMSCOPE c—C-MNT-TOPoNMOIMTNG KRANTENNA WITHOUT GPSwN ANDOVER SC18 AGMA t4 60 s RUSSETT LN. THREADED Y .a PROPOSED ENORTI ANDOVER,MA 0!845 SND FOR ANTENNA FIBERGLASS MOUNTING POLE—TOPEXTENSIONMT WASHER ISMALL CELL CANTENNA LOCK WASHER RADIO taJRtDIMENSIONS:37'Hx7+YWx8'D EQUIPMENT DETAILS DIMENSIONS: 15.1'ax24.2' 7/8'-9 HEX NUT WEIGHT:55 LBSWEIGHT:22 LBS _ S�£Q l9MBOt ANTENNA MOUNTING ANTENNA DETAIL + RADIO DETAIL 2 DETAIL 3 GENERAL WIRING DIAGRAM SCALE N.T.S L-3 SCALE N.TS L-3 SCALE:N.T.S L—} SCALE N.T.S L-3 1 -99 BANNAN DR., NORTH ANDOVER, MA 01845 X N ANDOVER SC20 MA LU .r a W J ©® Fnbq 9KMMm[9A P�FA�SSD �LMLGYV.wwatl� Mt:nn]1650n Hudson ��P`tH OF d3as� Q2 A EL P. KGs tit � CI 0.4 ; 0 • CNkT=S* J% ® APPMWW en Mi SUBMITTALS na eova or a ins men a sx wine N ANDOVER SC20 MA mcg t_M iM womtt narEri.ten 01045 • m¢r tmc t«• KEY PLAN �� wea wrneo� 33 N KEY PLAN t SCALE KTS �_, APPRMOMgM IAT' WX 40' COORDWAIM La1G xsr or 1o.9II' r FAST FYUIPEE 1.AN ANALYSIS OF THE CAPACITY OF THE EXISTING THIS LEASE PUN IS DIADRAMIANIC IN NATURE AND m STRUCNRE TO SUPPORT THE PROPOSED LOADING IS INTENDED TO PROWDE GENERAL IN ORMATION = WAS NOT am COMPLETED BY HUDSON DESIGN REGARDING INE LOCATION AND SME OF THE X GROUP.LLC.DRAWINGS ARE SUBJECT TD CHANGE PROPOSED WIRELESS COMMUMCATIDN FACIIIY. THE PETmiNG OUTCOME OF A STRUCTURAL AN-IMS. SITE LAYOUT WILL BE FDANILM UPON OOMPLERON W OF SITE SURVEY AND FACILITY DESIGN I.LI 2. SHOP DRAWINGS OF FINAL EXTENSION AND/OR ANTENNA NWHf 70 BE PROVIDED 70 ENtANFQR OF F:) RECORD PRIOR TD CON5IRUCNON. APPRDXINMTE LAT: N{Z AO'ZS.6B' W CODRDRLAhS LONG W7P o5� J TOP OF PROPOSED ANTENNA Hudson ®� 238'-0'3(/NASI-) PkOMM ANIAINA PROPOSED LESSEE(1) It61 a:'..000:rrtll F1EV.-38'-o't(AOL) ANTENNA 15.1'0 x 24.Y1-1 T _._ eus�ca+emL.vm mo av t*•gv.nm r...wurnr.m�o•us wnp:pmma 237'-0'3(/'/AST-) PROPOSED S' OSED -0l1 FIBERGLASSS "SION1 `11 GG_ONDA_„ D v _ EXISTING PRIMARY POWER r E E 1 TOP OF EX=KC UTILITY POLE ELEV.. 28-83 AG EXISTING GW WIRE s+�E?(ISTING—CD 230'-6't(AMSL) POWER sE..—Rr w _. A {OF &p PROPOSED WFATHERHFAD `} 'aA 2 E E -�* ANIEL P. Gf L i M OtiSNNO TELCD o CI ~ "' I o.4 7 0 NAL � EXISTING GUY WIRE CHECKED HY: J% PROPOSED RTS CONDUIT TO METER PROPOSED(1)//2'COAX IN 2' .ROVED BY: DPH CONDUIT FROM RRH TO ANTENNA 'A PROPOSED FIBER DEAARC BY 7 22'UO UARD IN � SUBMITTALS S, FIBER PROVIDER O 15'AGI. PRnPosED FIBER '�' p0C °�'� ■ PROPOSED AC/DC CONVERTER (FRONTHAUL&BACKML) PROPOSED RGS CONDUIT PROPOSED LLQ (1)AWS RRH PROPOSED LESSEE GOA FUSED PROPOSED SAR-0 " DISCONNECT&SURGE ARRESTOR PROPOSED LL4SEE METER O F� _ A Lara oatX b IX1571NC UDLfiY ( .-- N ANDOVER SC20 POLE MECO 01 MA 5'TD ' 'CAWva AI1911Effi M ADCORDANCWITH EXISTNC LrnLrY POLE 1-99 BANDYN DR. UTILITY COMPANY REQUIREMENTSq MECO t NORRI ANDOVER.M4 DIMS .S* b CROUNO LEVEL TTM ELEV.-0-0 (AGL) - I r r 201'-D'=(Aust) �_ I i._ n ELEVATION & PHOTO J-T -- 4 PROPOSED GRWND ROD ELEVATION GRAPHIC SSB s¢r roneDr 21.37 SCALE 3/8--1'-0- EXISTING0 L-z PHOTO DETAIL L-2 11z17 SCALE 3/t 6'a X'-0' SCALE N.T.S 1,t2 LEASE EXHIBIT NOTES: O¢• THIS LEASE PIAN S DIAGRAMMATIC IN NATURE AND I.AN ANALYSIS OF THE CAPACITY OF THE EXISTING •J IS INTENDED TO PROVIDE GENERAL INFORMATION STRUCTURE TO SUPPORT THE PROPOSED LOADING REGARDING THE LOCATION AND SIZE OF THE HAS NOT BEEN COMPLETED BY HUDSON DESIGN X PROPOSED WIRELESS COMMUNIGUPO FACILITY. THE GROUP,LLC.DRAWINGS ARE SUBJECT TO CHANGE 0� SITE LAYOUT WILL BE FINALIZED UPON COMPLENON PENDING OUTCOME OF A STRUCTURAL ANALYSE. d. Lu OF SITE SURVEY AND FACR.IIY DESIGN. 2. SHOP DRAWINGS OF FINAL EXTENSION AND/OR EXISTING OVERNEAD WIRES BELOW Cn ANTENNA MWNT TO BE PROVIDED 7D FNGMEER OF Q RECORD PRIOR TO CONSTRUCTION, EXISTING UTILITY POLE - a J MECO gI Hudson®@ PROPOSED LESSEE(1) `a - ANTENNA 15'0x242`H / r`.upacm :mttlrtx Ts+.Tlsm:sn EXISTING OVERHEAD ' `` ola5 ralaca. 1.1LRc5 BELOW •• 9 -�°" PROPOSED LESSEE I V52'Sl 9 (1)AWS RRH �z RRH DETAIL LAN a ;FEET15.1'0 ` N 2204 SCALE: �i ,.,- ',��� 11x17 scAt< /2 CF�N CF ,/4, A oEL ' 'G td PROPOSED ANTENNA CIV_ t an.4 . 6151 c• �'� Af~w Et"' +- PROPOSED CHECKED BY: _x J' LESSEE(1) — �NA 0 SECONDARY ( 1SI1�aQ0.217 N APPROVED BY: DPH, v _ I FIBER I FIBER FRONrHAUL SUBMITTALS B BACKHAUL e'A Ka m b �' � sAR D u r COMMSOOPE r I MO-MNT-TOP >' I O MOUMING KR oa Nim•uAsc amr a Ki ti :11ti j ;N N ANDOVER SC20 ANTENNA WITHOUT GPS �.. AC/DC CONVERTER MA -�- FIBERGLASS ISM SERVICE 0 1-99 BANNAN DR. it POLE-TOP EQUIPMENT NORTH ANDOVER,MA 0:844 L EXTENSION 7/8'-14 THREADED a�'r SND FOR MIENNA ��1 a I MOUMING RADIO UNIT -v, sxm TYIIE FIAT WASHER DIMENslous:37'Nx111YxB`D EQUIPMENT DETAILS SMALL CELL CANTENNA LOCK WASHER WEIGHT:55 LBS METER SOCKET WEIGHT- 15.1"6X14.2" 7/e'-s HU Nur wExxrr:22 LBS se•Er rAA4cR ANTENNA MOUNTING - ANTENNA DETAIL I RADIO DETAIL DETAIL GENERAL WRING DIAGRAM 5 SCALE:NTS SCALE-N.T.S SCALE NT.S SCALE:N.TS L-J 874 SALEM ST, NORTH ANDOVER, MA 01845 w N ANDOVER SC23 MA y a LU HudsonJ iao¢coonx.m uo.aswn�auae Sp[ah:9f •..owe�..0 ous rn nmswcw i �a�1H OF S� A, EL P. M � CI ~ o. 7 O mmcm 9r. ix APPROVED Br_ DPH SUBMWALS me oo�m� n mrm v as wm N ANDOVER SC23 MA sa.mnrm 874 WEN ST MOM ANDMMI ,NA 01845 air tma KEY PLAN KEY PLAN t airw�mw SUI.E:KT.S L-1 APPRO%.116E EAI: Nor,DEA1: 07.8 L-1 ICMM7T OC M.D- NOTES- LEASE E]MIRR TOP OF PROPOSED ANTENNA m 1.AN ANALYSIS OF THE CAPACITY OF THE EXISTING THIS LEASE PLAN IS DDARAMVATIC IN NATURE AND 178'-O'3(kmW STRUCTURE TO SUPPORT THE;PROPOSED LOADNG IS INTENDED TO PROVIDE GENERAL INFORMATION PROPOSED 1E55EE(1) WAS NOT BEEN COMPLETED BY HUDSON DE9GN REGARDING THE IDCATICN AND SIZE OF THE X OF PROPOSED ANTENNA ANTENNA 15.1'0 X 24,291 GROUP.LL.C.ORAWIIGS ARE SU4IECT TO CHANGE PROPOSED WIRELESS COAWIN IQkMON FACILITY. INE EI£/. ST—0 tt(AGL�� PENDING OUTCOME OF A STRUCTURAL ANALYSIS SITE LAYOUT WILL 5E FINAIZED UPON COMPLETION L OF SITE SURVEY AND FACILITY DESIGN. 177-0'f(AMSL) 2. 940P DRAWINGS OF FINAL CCFETALONAND/pR - 111 XOP OF EXISTING UTILITY POLE ANI MOUNT TO BE PROVIDED TO EN=CF N ELEV.-31'-6"f(AGS EXISTING UTILITY POLE STR RECORD PRIOR TO CONUCNON APPROIIMATE LAT: N42.40'07.6' Q 175'-6 (POISE) MECO#2424/1 COORDINATES LANG. W7r 04'4w PRO y�� J 10 ANTENNA 1/2'COAX Hudton IN 2 ,C ®® CONDOR FROM RRH I I Yr MECO POLE iP 2424 ON j f ( �y`.. I '•' 'rw c° '.ern�.� kw m,;,, SALEM STREET PROPOSED WFATNFRFEAD PROPOST9 FIBER FROM MECO POLE#2424 ON •4 r .f ,' 4'. SUSTREET E I T TG NOUS ¢OWER_ ! . . �DLISTINC HOUSE POWER UNE PM ME RGS CONDOR r TER +M` O H �`tH OF *A l EXISTING UTILITY UNE ,:,y • N VTI..-LI 3 AN M P. 'H EXISTING GUY WIRE « ,t. 0. 7�0 PROPOSED FIBER M 2• 4�• +��•' - ,per CONDUITPROPOSED FIBER DENARC BY e A•". ;� S>s`•l ��E�� ' orUL FIBER PRODDER O ts'AGL I PTNOEWSiD FIBER I (FRONHMUL h BACKHAUL) r PROPOSED AC/OC CONVERTER I `_, ' ( DUSTING UTILITY CHECKED BY. .AT POLE MECD 02424/1 's1, • r - PROPOSED RGS CONDOAPPROVED BY. DPH R •e. � � I PRO ( �1)ANS DL s+s �- SUBMITTALS PROPOSED LESSEE 60A FUSEL OLSCONNECT d SURGE ARRESTOR , PROPOSED LESSEE METER Q SAR-0 SED . ISI0 Ot/NLAl Rt tT4[®f D 9R NVRS N ANDOVER SC23 MA S.TO W-r(PGL) INUTILITY A=RDwMM COMPANY AIL AOnffSS REQUIREMENTS 41 41 NORTH 874 SAE Hq 01815 GROUND LEVEL 311w tell D.EV.-O-Ot ACL "�ldilhJdll —111—II IL- 144'-D"f(AMSL) J �I�1 i=.I �T=� �IC=1�, II=1 ELEVATION & PHOTO I I PROPOSED `. GROUND ROD - 9eT mlteol �� SIG SCA F ELEVATION / 1 \ �Y�•y�e• S'-4' 6'-D' EXLSTING PHOTO DETAIL 2 \ -2 22.34 SCALE'3/8"-1'-0" L-2-2 SGJ.E:N.TS l-2 11.17 SCALE.3/16•-i'-D' LEASE EXHIBIT NODS: � THIS LEASE PIAN.IS DWISTI CRAMMATIC IN NATURE'AND 1.AN ANALYSIS OF THE CAPACITY OF THE EXNG j/ m IS INTENDED TO PROVIDE GENERAL INFORMATION STRUCTURE TO SUPPORT THE PROPOSED LOADING REGARDING THE LOCATION AND S2E OF THE HAS NOT BEEN COMPLETED By HUDSON DESIGN K PROPOSED WIRELESS COtAAUNICATON FACILITY. THE CROUP,LLC.DRAWINGS ARE SUBJECT TO CHAN LV SITE LAYOUT WILL BE FINALIZED UPON COMPLETION PENDING OUTCOME OFA STRUCTURAL ANALYSES. OF SITE SURVEY AND FACILITY DESIGN EXISTING UTILITY POLE 2 SHOP DRAWINGS OF FINAL EXTENSION PND/OR �; UJI ANTENNA MOUNT TO BE PROADED TO ENGINEER OF c VECO 02424/1 RECORD PRIOR TO CONSTRUCTION. a _� PROPOSED LESSEE(1) Q ANTENNA 15.1'0 X 242'11 LLI PROPOSED 6 - ( R` J Hudson oT � DmIan Grmp=�s UaKGT'P.aH.YW. .F'�12h.^.M 0 �--�'� TTT---------EXISTING GVERHEAD WIRES BELOW •r 9� 1i, 4 CST SPA C^ai c w4 RRH DETAIL PLAN 4 p I 2 3 FEET z E'� 22X34 SCALE zz 11.17 SCALE I/2'=/•-o' `�`;� 'kS r .. PROPOSED ANTENNA f `S`^tlAt c 4� - LESSEE PROPOSED) ANT�LA ct EacD ar. 1K I 15.1'6 24.2'H � a .y A N SECONDARY (i1i1i( A� APPROVED BY: DPH i ?FIBER SUBMITTALS FIBER FRONTHAULlSDCI(Er ORO. ad occ oco� m &BACKHAUL * �•: I COMMSCOPE STAR-0 . MC—MNi—TOP uouNTNc KT a m/w.artvac—! � � 67 N ANDOVER SC23 ANTENNA wrrHouT cps EXIsr.4 UDL VAc/Dc cDNYMA POLE BOA SERVICE 874 SALEM ST *I EOUIPMENT KORTH ANDOVER.MA 01845 7/8'-14 TFRZ2EADEDMSTUD OUNTING NdiENNA.TFAT WASHER RADIO UNT EQUIPMENT DETAILS SMALL CELL CANT. LOCK WASftiRDIMENSIONS:37*Hx11•VVXB'D ME DIMENSIONS:I5.1'MQ42' 7/8'-9 XIX NUT WEIGHT:55 LBS WEIGHT:22 LBS s ZT ANTENNA MOUNTING L_3 ANTENNA DETAIL L13 Rs� e A010 DETAIL La SCALE-- �3a GENERAL WIRING DIAGRAM Hudson .H, -- - _ - -00rp ,�—, •, � + "stay "`..�r � �ti�' ntnroer.n vowrn e n^,I I,nrou '• r brg[p Ir'rr IYI nNo wow,role�IccuBrn; y� ti • "f E IINiNG TNn .S YI iUTILITY •01 f, 1 ~icy„ _ 7. r I ii1U lrnl ll'r 5 Rtopo:.r0 It. M>3uurro m cM;•nN,. �DOO trul.m rglr. e MaDa ' + N ANDOVER MA 77.c287-381 CK%XERM RD jy l 0 NONE WASE FtMIRR AN ANALYSIS OF THE CAPACITY OF THE EXISONG THIS LEASE PLAN IS DUCRMDIATIC IN NATURE AND m STRUCTURE TO SUPPORT THE PROPOSED LOADING IS INTENDED TO PROVIDE GENERAL INFORMATION = HIS NOT BETON COMPLETED BY HUDSON DESIGN REGARDING THE LOCATION AND SIZE OF THE X GROW,LLC.DRAWINGS ME SUBJECT TO CHANGE PROPOSED WRELESS COMMUNICATION FACILITY. THE PENDING OUTCOME OF A STRUCTURAL ANALYSIS. SITE LAYOUT WILL BE FW4U2ED UPON cOEPlET10N W OF SITE SURVEY AND FACILITY DESIGN. W TOP OF PROPOSED ANIIIOU. N -��e t APPROXIMATE UT: N42'41' ED 13.1' a 220'-8't SU PROPOSLESSEE(1) COOROUVATES`. LONG: W71'07'16.1• J O PROPOSED MT � A TEMFU I&VO X 21.211 ELEV..29'-8-3(AOL) •, • Hudson 219'-r:h(AMSQ PROPOSED CUSTOM MOUNT _ 'N TOP OF 6'fING UnLTiY POLE EXISTING GUY WIRE ElEV. 28'-0 3 AMU PROPOSED POWER FROM 218'-0't(AMSU ME X2712 r C n,ipc�•[yk m Y1d rima jrr ACROSS PROPOSED WFAIHERHDDPROPOSED FIBER FROM MECO POLE E2'712 `^,fpy r• j, ACROSS STREET .: IXISTLW CLAY WIRE ,,•x � '•". EXISTING UTILITY POLE -•�VA •. ..; .+- MECO 42712/21204 • V G C PROPOSED RGS CONDURT PROPOSED(1 1/Y COAX - 70 METER �Y )FROM RIM ANTEMNA EXISTING GUY WIRE N a1PUUIT EIDER 8i 2'COND bl * PROPOSED FIBER DEMARC SY G Im r . 19, ro FBM PROVIDER O 16'AGL IPROPOSED FIBER + � o PROPOSED Ac/DC CONVERTER EZIsTNG unuTY-POLE CHECIED BY: Jx 1 MECO 82712CONDUIT9a PROPOSED RGS CONDUIT - - - Sk. - APPRWEb BT: DPH PROPOSED LESSEE SUBMITTALS PROPOSED LESSEE 80A FUSED (1)AWS RRH R ,z DISCONNECT k SURGE ARRESTOR PROPOSED LESSEE METER OW-0. ^.. L i c - t.. P W/t1113 M 186[00trf � ' ; SRIE Alli_ ' N ANDOVER SC27 3r,TO B.-6.(AW 4_.__ MA M ACCORDANCE WITH J ,• UTILITY COMPANY ... REQUIREMENTS N ttt y;, y � _,.-R 28718I CH=NICKERIMG RD 4, NORTH MAWER,LIA Dim GROUND LEVEL ,Y ELEV.=D—D t ACL I Lit I I I� 190'-0'3(AMSU •I df .I II�''y - ar t e ,... —� NOT f( i �' t "r r� g ELEVATION & PHOTO —II Jj rJIEILI ' + r } PROPosED 4� 'at GROUND ROD ELEVATION t ELL STALE:3/e'=t"-D' L-z 0 1'-4'.7-8' s a' a'-a' EXISTING PHOTO DETAIL 2 L-2 11z1 7 SCALE.3/18'.1'-0' SCALP:N.TS L-2 LEASE FMBIT Nph. THIS RAS LEASE PIAN IS DIAGWTIlC IN NATURE AND AN ANALYSIS OF THE CAPACITY OF THE EXISTING Ln 6 INTENDED i0 PROVIDE GENERAL INFORMATION STRUCTURE TO SUPPORT THE PROPOSED LOADING REGARDING THE LOCATION AND SIZE OF THE HAS NOT BEEN COMPLETED BY HUDSON DESIGN PROPOSED WIRELESS COMMUNICATION FACILrTY. THE GROUP,LLC.DRAWINGS ARE SUBJECT TO CHANGE EXISTING UTILITY POLE W SITE LAYOUT WILL BE FINALIZED UPON COMPLETION PENDING OUTCOME OF A STRUCTURAL ANALYSIS. MECC / OF SITE SURVEY AND FACILITY DESIGN. 612712 21284 w PROPOSED LESSEE(1) a ANTENNA 15.1'0 X 20.211 W PROPOSED LESSEE (1)AWS RRH Hudson ® H S C m .r:r�arara. 0 m a �. 'T 1 -� :.1 PROPOSED LESSEE(1) ANTENNA 15.1'0%20.211 - �jE RRH DETAIL PLAN < p s 11 2 7 T1ET 22.34 SCALE: JZ �� 11.17 SCALE: y 1x• PROPOSED ANTENNA a •� CHECKED EM i7 �A 01 SECONDARY N I I APPROVED.BY: DPH E > JC FIBER PROPOSED CUSTOM FIBER GRD. SUBMITTALS MOUNT &BACc�1' P SAR-O �,"-� c dANTENNA WIHOUT GPs N ANDOVER SC27 ACMA E%ISrNIG UTILITY POLEM_OO#2712/21284 287-361 CHICKERING RD 7/B'-14 THREADED EONCRTH ANDOVER,MA 01845 STUD FOR ANT"7 MOUNTINGIFLAT WASHERLOCK WASHERsMAL CELL CANTENNA RADIO UNIT EQUIDIMENSIONS:15.10.24.2" 7/8"-9 HU NUT DIMENSx1P16:37H.11Yh wElcHr:u Iss wElcnr ss Igs • T WYpER ANTENNA MOUNTING �_� �ANNTEN'NS DETAIL r�i\ RADIO DETAIL L23 scA�Au�.s L3J GENERAL WIRING DIAGRAM L53 452 CHICKERING RD., NORTH ANDOVER, MA 01845 N ANDOVER SC28 MA Lu co W Hudson K yy � � r:.•can!wm.c v iraar.:a. ANIEL P, �'yG ct _ I OL— AV rowu.� a11f .? ' CHECKED SY:INC JX , '. '• rOVEO BY: DPH SUBMITTALS OAL a®o. m �i ro f r� ; w sa wmo N ANDOVER SC28 MA 452 CHICKERING NO01 RTH ANDOVER.NA 07845 7 � 2015 81ING SNRT.". lest' KEY PLAN U �o ��� �Z SNRT MVI®1 X KEY PLAN �L SCALE N— L-1 APPROXWE M N42 41']Z80' R COORIDIWIM LONG *71'Ur faeD• NOM' LEASE EXHIBIT h 1.AN ANALYSIS OF THE CAPACUY OF THE EJOSTING THIS LEASE PLAN IS DWIRXA 'NIC IN NATURE MID m STRUCTURE TO SUPPORT THE PROPOSED LOADNG IS INTENDED TO PROVIDE GENERAL D!F'ORMATN]N WAS NOT BEEN COMPLETED BY HUDSON DESIGN REGARDING 11HE LOCATION AND SEVE OF THE X GROUP,U.C.DRAWINGS ARE SUBJECT TO CHANGE PROPOSED WORDLESS COMMUNICATION FACILITY. THE PENDING OUTCOME OF A STRUCTURAL ANALYSIS. SITE LAYOUT WILL BE FINALIZED'UPON COMPLETION LLI OF SITE SURVEY AND FACITM DESIGN. LU 2 SHOP DRAWINGS OF PROVIDED EXTENSION MID/OR ANTENNA PRIOR MOUNT Tb N PROVIDED TO ENGINEER OF Q RECORD PRIOR 70 CONSiRUCRON. APPROfOW7E IAT: M47 41'3240' LLL COORDRUOFS: LONG: Vl7r 07'13.60' ...1 TOP OF PROPOSED ANTENNAtt Hudson ELEV.-38'-10"± `tt'•'R'CO OoaORG ® 400'-1077(AWL) 4_]' iN ELEV.-F35-Bt ANTENNA I¢ liveaclmn�i raxm: -s by arca 1GD'-8't(ANSI.) PROPOSED LESSEE(1) TOP OF IXSTING UTILITY POLE ANTENNA.120'/X 2B.71N rucp:ala..•.a� ELEv.®34-D t AG _ IXSING SECONDARY 196'-D"}(AMSJ POWER O Tn EXISTING UTILITY POLE - 93500 IX6TINC SECONDARY POWER C ' ELEV.�29-0 ACL �.EXISTING SECONDARY 193'-D-S(AMSC) POWER IXISTNG UTILITY POLE PROPOSED WFiATHERHFAD 9 350D 4 FA��N OF d;qs ANT E1 P. � • r' CI PROPOSED FIBER(T.&D) - r a 4 720 { PZ< I1r 0 n PROPOSED RGS CONDUIT TO MEIFR PROPOSED(1)FROM COAX ! CHEam ft ,At * M YAC FROM RRH PROPOSED FITTER IN APPROVED BY: DPN PROPOSED FIBER DEMARC BW Y U-GUARD SUBMITTALS FIBER PROVIDER O 15'ACL. PROPOSED AO/OG CONVERTER PROPOSED FIBER xor. oR mwld e (FR mmx h WXNAUL) PROPOSED RGS CONDUIT PROPOSED LESSEE (1)AYES RW1 PROPOSED LESSEE 60A FUSED PROPOSED SAR-0 - DISCONNECT k SURGE ARRESTOR t 0qwD IRYOT 1101 mYpm 6 PROPOSED LESSEE ME1EIt t e Vn txa N ANDOVER SC28 S - MA S'TO B'-6'(ADtJ � _ s11C A0f9Esx IN ACCORDANCE WITH REMENTS unuTYOUI CO -' - 452 CHECKERING RD NORTH ANDOVER,UA 07845 N LL,l b GROUND LEVEL 51�f YA1£ ELEV. 0-0 (Act.) L 164'-0 (AMSC) '� � i - MIL r - - ELEVATION & PHOTO GROUND ROD GRAPHIC _1 m1Ea1e11�n C SCALE ELEVATION 1 Yi' L-2�n 2D134 SCALE 3/6'-t'-D- L-4 EXISTING PHOTO DETAIL 2 L G 71.17 SCALE 3/16'-1'-0' SCALE N.LS l-2 LEASE FYMINR LL r THIS LEASE PUN IS DIAGRAMMATIC IN NATURE AND I.AN ANALYSIS OF THE CAPACITY OF THE EXISTING / m IS INTENDED TO PROVIDE GENERAL INFORMATON STRUCTURE TO SUPPORT THE PROPOSED LOADING PROPOSED LESSEE REGARDING T11E LOCATION AND SIZE OF THE HAS NOT BEEN CONPUEiED BY'HUDSON DESIGN (1)AWS RRH 3 X PROPOSED WIRELESS COMMUNICATION FACILITY. THE GROUP,LLC.DRAWINGS ARE SUBJECT TO CHANGE r SITE LAYOUT WILL BE FDIALIZED UPON COLIPLEDON PENDING OUTCOME OF A STRUCTURAL ANALYSIS. EXISTING��. 7 x OF SITE SURVEY AND FACILITY DESIGN. POLE#3500TI S W 2. SHOP DRAWINGS OF FIX EXTENSION AND/OR N ANTENNA MOUNT TO BE PROVIDED TO ENGINEER OF (BELOW ANTENNA) RECORD PRIOR TO CONSTRUCTION. PROPOSED LESSEE Q (1)ANTENNA '`-'�\ C7 W 120'ex28.7"H J EXIST NG OVERHEAT '\ � jI / C Hudson WIRES BELOW ��-- DCIIpD 6foUpee® a � I�o•.:ooarnr: - I I.rcmme%�u.'taex["'a tm+AIL^-L'O _nmlama� _. • �� s3 ta52' • � Ei RRH DETAIL PLAN �a1 r.RA_ PHIC i� 12.0"0 Y a 12x34 SCALE: t'.1'-0' 4 ±'!�TETT 11x17 SCALE: 1/2"-1'-O" { ANIEL P J, LA. '• PROPOSED ANTENNA C - �` �IGAJAI I {N CHECKED BY: JX SECCNOAR" APPROVED BY: DPH G ( PROPOSED LESSEE(1) IF-Ml-UL FIBER SUBMITTALS + ANTENNA 12.0'0 X 2&7'H FIBER GPM t 4 &BACSAR-0lb Is e ia�COMMSCOPEMC-MNT-TOPMOUNTING 10T ; N ANDOVER SC28 AMA COMMSCOPE BO452 CHICKERMG RO MC-MNT-TSA EONORTH ANDOVER,MA 01845 MOUNTING KRPOLE EX+STINGUTIL'T`'SMUL CM ANTtSNNA RADIO UNIT EOUIPMENT DETAILS COMMSCOPE NH3600SdA ' DIMENSIONS 12.0'0 x 2&711 WEIGHT:27 LBS _ aIm rs®t ANTENNA MOUNTING ANTENNA DETAIL RADIO DETAIL z DETAIL GENERAL WIRING DIAGRAM I�� L_3 SCALE:N.T.S l-3 SCAL N.S l-3 SCALE N.T.S �L-3 1 SCALE:N.TS A L=;T m_ z 57-99 PARKER ST. NORTH ANDOVER MA 01 845Lu N ANDOVER SC29 MA W J Hudson +'.�nasssn by �j v oANIEL P. �J+ CI o. 7 0 CHMM Em. APPROVED sr: DPH SUBMITTALS ' r rx ooc goy m f 9R raMC N ANDOVER SC29 MA � ,A v¢AODkF33: 57-99 PARKER ST K ANDOVER MA,07895 kv _ sw=7R,d tss7 KEY PLAN W X KEY PLAN t r StJ LE:N.T.S L_, Ar.►i�.lAlE tAT. L-1 vnr GY 2 7.zz' 32'-11't 31'-8't 30'-0't �o pO m�p 1 ✓� 1 0'� l a 1�1 _ t yy yy o y gg 1 � A � a• � k I I I' CC ulHO t s_o: �v L� 1Fs N e b 10't(IfU(8MOM EOUIPYElR) 1 jig 1.5 M MIA X N d 0 IN I s �aIRV, t � Z Z � z LEASE EXHIBIT r Z 9 gggg" A " t?ditgA!r � Z N foo' 3� 3 N F e 0 co e a LEASE EXHIBIT NOTES, THIS LEASE PIAN IS DIAGRAMMATIC IN NATURE AND 1.AN ANALYSIS OF THE CAPACITY OF THE DDSDNG _ IS INTENDED TO PROVIDE GENERAL MFORMATIDN STRUCTURE TO SUPPORT THE PRCPOSED LOADING PROPOSED FIBER&POWER REGARDING THE LOCATION AND STLE OF THE HAS NOT BEEN COMPLETED BY HUDSON DESIGN PROPOSED WIRELESS COMMUNICATION FACILITY. THE GROUP,U.C.DRAWINGS ARE SUBJECT TD CHANGE A y � #°� X SITE LAYOUT WILL BE FINAIRED UPON COMPLETION PENDING OUTCOME OF A SO2UCTURAL ANALYSIS. a\ I3] OF SITE SURVEY AND FACIJIL'DESIGN. 2. SHOP DRAWINGS OF FINAL ONENSION AND/OR a L3J ANTENNA MOUNT TO N PROVIDED TO ENGINEER CF (n RECORD PRIOR TO CONSTRUCTION, LU 4 Q MSTING UTILITY POLE MECOi14464 V' 's Hudson D"6-Gmup- �coWa.`comz+s, PROPOSED LESSEE(1) ro.a.s�xxe sn na m-sva ANTENNA 12.0'0x2fl.7'H PROPOSED LESSEE (1)AWS RRH' �. PROPOSED CONCEALFAS UNIVERSAL CANTENNA SLEEVE L .s s /1111'2T�� 1�1,, � •RAPHtr Graf c 12.0'e - a41�j'ES RRH DETAIL PLAN 4 D 5 1 i 3 Im 11V 22x34 SCALE:t"-t'-0" l-3 ' rX 11.17 SCALE 1/2'=1'-0- C`ANI__ P. 4 • PROPOSED ANTENNA G �� .4 D �7_0 ff � SSfQNIX- r. CHECKED BY: J% --r6SECONDARY N APPRGVED BY: DPH ( I FflER SUBMITTALS FIBER FRONTHAOL CRD. &BACKHAUL nd. 0sII smvlop d UNIVERSAL CAHIENNA SLEEVE >. R (AS REQUIRED) SEAR—D u vu—i a w j 1 w/nVa r«uxu CONCFALFAB WIDE DIDIAMETER POLE—TOPOL. N vrt ww N ANDOVER SC29 AC/OC CONVERTER MA � i m Acox� COMMSCOPE ;j'•rA,+ GOA SERVICE 57-99 PARKER ST + MC—MM—TS/ >�' EQUIPMENT & N.ANDOVER M4,O7B45 --MSMOUNTING KIT EXISTPOLE G UTILITY J POLE 'I i \6 94R:IRS RADIO UNI WALL CELL W MMA DIREI19IONs:s7 LRx17 wxsro I I I I oN EQUIPMENT DETAILS COMMSCOPE N113WOS—DG—EDM 65 LBS 11 DIMENSIONS:12.0'0 x 28.7, METER SOCKET WEIGHT`27 Las ANTENNA MOUNTING _ s,TCR,AhIOFA DETAIL ANTENNA DETAIL t RADIO DETAIL 2 s51 :N.T.S Lia GGEENERAsL WIRING DIAGRAM L-3 SCALE N.TS L-3 SCALE N.T.S L-3 532 CHICKERING RD. NORTH ANDOVER, MA 01 845 X N ANDOVER SC30 MA W u - J �J Hudson®� dig � x xr APPR W Sri DPH f SUBMrrrALS. m om �m a { • r ' e omro�� N ANDOVER SC30 C MA tV NORTH ANDOVER MA�O1845 j46 KEY PLAN 7457 x KEY PLAN jRL St.AL£N.TS L-1 APPR07Q1MTE IAT: N42 il'422' L COMMUM IDNL. vr"07't02' 2lDIE IEASE EVUIPIT AN ANALYSIS OF THE CAPACITY OF THE EXISTING THIS IESE PUN LS DNGRAWWW IN NATURE AND m STRUCTURE TO SUPPORT THE PROPOSED LOADING IS INTENDED 7D PROWDE GENERAL TNPORWTIDN HAS NOT BEEN COMPLETED BY HUDSON DFSIGIN REGARDING THE LOCATRDN Atm SQE OF THEU.r_DRAWINGS ARE X PFNOAIG COMMUNICK1130H FACILITY. THE OUTCOME OF A STRUCNR L ANATO L SITE LAYOUT PROPOSED WILL BE FINALIZED UPON COMPLETION W OF SITE S MEY AND FALTLBY DESIGN. w CIO APPROXIMATE IAT. NIS 41'42.2- TEs: LONG; wn-oY toz' J Hudson D N EXISTING SECONDARY POWER raRae.arn.sc.x. u R%dsha TDP- AN PROPOSED IEMNA �,�...�•'• '--^amu• —" PROPOSED I (1) - t4B'-8't CAMEL) ARIQ/NA 15.1•o x 24.27N TDP OF IX-0ISTNG (AGN UillUf'!POLE PROPOSED CUSTOM MOUNT ELEV.-28 t N 147--0"3(AMSL) FX(ISTNC SECONDARY POWER EXISTING TELCO EXISTING TELCO PROPOSED WFAHfrRHEAD FIBER r # UTILITY POLE MEXISTING - - MECOCO}4825 EXISTING FIBER _ PROPOSED(1)1/2'COAX IN z'CONDUIT FROM ARM M PROPOSED RCS CONDUIT TO METER TO ANTENNA I"•: + 1. Y ,N PROPOSED Flom IN � +y+..w �.+... CHECKED or. ix R o PROPOSED FIBER DEMARC BY 2•U-SUMO I NI FIBER PROADER O iS AGA. r`" APPROVED BY: DPH PROPOSED AC/DC COWFRTQN PRO((FRO�L FIBER BACgWUL) N +�._ ._ ... SUBMITTALS N PROPOSED RCS CONDUIT I PROPOSED LESSEE - DISCONNECT&SURGE ARRESTOR PROPOSED LESSEE BOA FUSED —PROPOSED SAR-0 PROPOSED 1E55EE METER SiIE rvJR` 5•TO �- N ANDOVER SC30 IN ACCORDANCE AKTNN - .•r '•""`"` REQUIREMENTS COMPANY S . NA MECO 4825 �.. SEE AOOIm` 532 CHICKERDIG RD, R NORTN ANDOVER,MA 01845 �CEOlMO LEVELU ELE� V.a'D 0 3(ACL) ritr- �jr 719'-0`t(AMSL) �E1� SIQiT Mae PROPOSED GROUND RDD ELEVATION & PHOTO ELEVATION 22.34 SCALE:3/e'-1'-G' L-z EXISTING PHOTO DETAIL 2 11x77 SCALE 3/16'st'-0• SCALE NLT_S L-2 GiK LYMIBR �; PROPOSED LESSEE THIS LEASE PLAN IS DIAGRAMMATIC N NATURE AND AN ANALYSIS OF 71GE CAPACITY RO THE EIO LOADING (1)AWS RRH m R INTENDED TO PROVIDE GENERAL I OF TH RON HAS SNOT S EM SUPPORT THE PROPOSED DESIGN REGARDING THE LOCATION AND SIZE OF THE HAS NOT BEDI COMPLETED BY HUDSON DESIGN PROPOSED WIRELESS C061ANICA71ON FACILITY. THE GROUP,LLC.DRAWINGS ARE SUBJECT TO CHANGE DaS TING U1Rltt POLE EXISTING CVERHEAD x SITE LAYOUT WILL BE FINAUZED UPON COMPLETION PENDING OUTCOME OF A STRUCTURAL ANALYSIS. MECO#4825 WIRES BELOW W OF SITE SURVEY AND FACILITY DESIGN. PROPOSED LESSEE(1) LU . ANTENNA 15'Ox24.2H a,�--> cnQ J a Hudson Dei z� I�>xxxa:nm O. A <: \\\ A I 652' • &1 "' RRH DETAIL PLAN i �ox��g 2zx3a scALE: i—I—o L-3 PROPOSED LESSEE Y 11x17 SCALE 1/2'-1'-0' 24.2-H 4. . ANTENNA 15.1'0%24.2 yR N _ _ PROPOSED ANTENNA Q CHECKED BY: JX e SECONDARY APPROVED BODPH FIBER SUBMITTALS FIBER FRONTHAUL- -- CRD. tom m ;- &BACKHAUL n PROPOSED CUSTOM MOUNT J S> a a/mV.vis mm Ire hat �Y. �.. HHS ANTENNA WITHOUT GPS } N ANDOVER SC30 d I I ACAC CONVERTER MA !/( src AnaNes J.� `as, 60A SERVICE 532 CHICKEMG RD. 1J 7/8'-14 THREADED rl EOUIPMENT Ra NORTH ANDOVER,MA 0184S MOU3 SND FOR FLAT WA "—DaSTING G UTILITY POLE 11 FIAT WASHER MECO#4825 0 I vKLr m1X LOCK WASHER RA00 UNIT CELL CANTENNA orMLaSIONs:3rHx11wx6ro - EQUIPMENT DETAILS DIIISIMONS 15.1"0x24.2" 7/8"-9 MDL NUT WEIGHT:55 LBS WEIGHT-22 L85 METER SOCKET ANTENNA MOUNTING _ SHFET 14meN ANTENNA DETAILALE RADIO DETAIL 1 2 DETAIL SCALE:N.T.S �� GENERAL WIRING DIAGRAM 5 L_3 L-3 SCN.T.S �� SCALE N.T.S L-3 SCALE:N,T.S L-3 l • ! 1 0 r H G .1 ' S 4 �� �F�Dpb`st r t t f a A4TEN n u ar r u. F7lISTiv.uh . uruc r � ti �r �-�P.,ROPDSff NPI, 1'IOUNIfto, lo17 z ) ti r 44 CifMA 405 OSGOOD ST.ROM ANDOYM.WA Ola" AllT; n, M1 s Wk.. NOTES, LFASF EXHIBIT 1.AN ANALYSIS OF THE CAPACITY OF TFRE EXISTING THIS LEM PIAN IS DIAGRAI®DOIC IN NATURE AND m STRUCTURE TO SUPPORT THE PROPOSED LOADING IS INTENDED TO PROVIDE GENERA-INFORMATION HAS NOT BEEN COMPLETED BY HUDSON DESIGN REGARDING THE LECTION AND SIZE OF THE X GROUP,LLD.DRAWINGS ARE SUBJECT TO CHANGE PROPOSED WIRELESS COMMlROCATION FACIIIIY. THE PENDING OUTCOME OF A SIAUCRNLL ANALYSIS. SIZE LAYOUT WILL BE FINALIZED UPON COMPLETION W OF SM SURVEY AND FACILITY DESIGN. w 2 SNAP MOUNT T O OF FOUL E TO ENI AND/OR ANTENNA MOUNT m BE PROVIDED m ENGRffETi OF Q RECORD PFM TO CONSTRUCTION. ATiNOXiMATE LAT: N42 41'.45.10• COORDINATES LANG W7r D8'8O9D• Lu a6tApPY1CP,Y:UIEb00 IL fY.X'�,yya Hudscm M/.wWVF..WOYW {U_PT� EDP OF PROPOSED ANTENNA 1J3'-10'3 T/1L/SI) OF PROPOSED ANTENNA EXISTING GUYWRE EI.EV.-31-8 3PROPOSED LESSEE(1) 132'-8'3 moANTENNA 12.0'V X 21t7'H LOP OF EXISTING UTTLPY POE ELEV--30-D':t(ACL) ACL - 131'-O'3(AMSL) EXISTING UTILITY POLE EXISTING GUYWIRE OECD#947-84 `��F f PROPOSED WEA NERNEAD �FP�' `s9c EXISTING UTUTY POLE AN cL P. yf PROPOSED POWER FROM MECD#947-84 EXISTING UTILITY MMMDfR4-54 ACROSS STREET EXISTING CUTWIRE - CI PROPOSED FEER FROM o.4 720 EXISTING UTILITY POLE \\\ 947-84 ACROSS �- 'r... ` r- �.: ��'rSTSTREETt10 \4�� r. Ssip �� PROPOSED RGS OONDUT m METER PROPOSED(1)1/2-COAX �,vx CHECKED er. 3x IN 2'CONDUIT FROM RRN _ a IGX6TNG GUt WIRE m ANTENNA E i APPROVED BY: DPH 'a m 718--5'3(AMSL) n n o EXISTING CUYWIRE SUBMITTALS M PROPOSED AC/DC CONVERTER mt r4 o,t>a,d Po PROPOSED RGS CONCUR LESSEE Si (1)�AIVS�RRH ,1. PROPOSED LESSEE BOA FUSED PROPOSED SAR-0 DISCONNECT&SURGE ARRESTOR 't An1/u rsr c4yOAs ,¢ PROPOSED IESSl7:METER � [' 0 WJ7f/IS W� JI Y� 91F ttA,P: �+ N ANDOVER SC32 :4 MA IN ACCORDANCE S To ////y tuTE AtM64 UTILITY COMPANY Y' 408 OSGOOD St NORTH REQUIREMENTS Eb A✓DOVER,MA 01845 'O CROMND um LEVEL ".,�AtAst►. s -Y f I 514E71 EIEv.>0-0'f(AIL) �•• u � r T 01'-0'a(AMSL) 'yi�^I�F 'L I�1'�-iY +.'w.+r`y'- w3 �_ ra d ELEVATION 8c PHOTO PROPOSED GROUND RDD ,a.. . ELEVATION ' "A+C'aCA- ""LF 22W SCALE 3/a'-t'-o' L-2 EXISTING PHOTO DETAIL 2 11.17 SCALE 3/18'-1'-0' SCALE N,TS L-2 L-2 LEASE E(mw NOS: PROPOSED LESSEE F � THIS LEASE PUN 13 DIAGRAMMATIC IN NATURE AND 1.AN ANALYSIS OF THE CAPACITY OF THE DRSRNG (1)AWS RRH m IS INTENDED TO PROVIDE GENERAL INFORMATION STRUCTURE70SUPPORT THE PROPOSED LOADING PROPOS®LESSEE(1) _ REGARDING THE LOCATION AND SIZE OF THE HAS NOT BEEN COMPLETED BY HUDSON DESIGN PROPOSED WIRELESS COMMUNICATION FACILITY. THE GROUP,LLC.DRAWINGS ARE SUBJECT TO CHANGE ANTENNA 12'�x2&7'H /a X SITE LAYOUT WILL BE FMAUZED UPON COMPLETION PENDING OUTCOME OF A STRUCTURAL ANALYSIS. OF SITE SURVEY AND FACILITY DESIGN. ,M1 g LL! 2. SHOP DRAWINGS OF FINAL DMOON AND/OR DUSTING LFTLITY POLE W ANTENNA MOUNT TO BE PROVIDED TO ENGINEER OF MECO#947-84 r N RECORD PRIOR TO CONSTRUCTION. (BELOW ANTENNA) a. % Lu EXISTING UTILITY POLE Hudson® MECC$947-64 �, TbMCP Gmp— lb rvlTxm et ra:a:w p5 cavus +c ra ass w .• y �y 1d52 A _ �Y\►I W� • + 94 2 RRH DETAIL PLAN r4 D raAPwC SC LE 3 FEET T 12.o'4 -: _ 22x17 S 11.17 SCCAALE:1/2r;-D' L-3 0.Uf . ANIEL m sO '• PROPOSED ANTENNA ' _ o.4v7i C �S7�r.!!L m I � CHECKED BY: JX !!rr 'A•• S E C O ND A R Y APPROVED H1. DPH PROPOSED LESSEE(t) FIBER SUBMITTALS ANTENNA 1200 X 2&7'H FIBER FRONHAUL GRD. .k BACKHAUL dR m 0 4�1 SAR-O ' �bA r' n g o W w.uat mmvmeaAc a rCOMMSCOPE H 9RC uwc ! `�f !! MC�KnNc N ANDOVER SC32 e AC/CC CONVERTER MA j _._ z srl.00a5s COMMSCOPE _ 0 60A SERVICE 406 OSGOOD ST.NORTH MOUNTING 51 EOUIPMER ANDOVER,MA 07845 MOUNTING AOT - rr EXISTING UnuTY PaE �6 t � sa[r anc SMALL CELL wTENw RADIO UNIT wti EQUIPMENT DETAILS COMMSCOPE NH3600S-DG-FOM DIMENSIONS:37'Hx11'WY6b METER SOCKET DPIENSIONS:12O'o x 26.7'H Ay�,IT.NS L� WEIGHT:Z7 LBS vrcLT Nw eu ANTENNA MOUNTING - ANTENNA DETAIL 1 RADIO DETAIL 3 DETAIL �N GENERAL WIRING DIAGRAM s -fS� SCALE:N.T.S L-3 SCALE:N.T.S L-3 SCOL E N N.T.S L-3 SCALE. L-3 L-3 } >. f AM�rp� - - CAN 4AU MStING=UTIUIY I'AS�A 6P'�5E Rtill �' 1 TV inY,vALM •>w MA 7M OSC=ST 1 - t 0 NOTES,. 1 FACR FYMRR �' 1.AN ANALYSIS OF THE CAPACITY OF THE EXISTING THIS LEASE PLAN IS OIAGRAMIAVC IN NATURE AND m STRUCTURE TO SUPPORT THE PROPOSED LOADING IS INTENDED TO PROVIDE GENERAL INFORMATION HAS NOF BEEN COMPLETED BY HUDSON DESIGN REGARDINGUPTHE LOCATION AND SDE OF THE X GROUP.LLD.DRAWINGS ARE SUBJECT TO CHANGE -PROPOSED VARE ESS COMMUNICATION FACHJTY. THE • PENDING OUTCOME OF A STRUCTURAL ANALYSIS. SITE LAYOUT WILL BE FINALIZED UPON COMPLETION LU TOP OF PROPOSED ANTENNA OF SITE SURVEY AND FACUTY DESIGN. ElEV.-41'-*'* 2 SHOP DRAVACS OF Il 1.EXTENSION AND/OR LLJ 2ffY-0't(AMSC) ANTENNA MOUNT ID BE PROVIDED TO ENGINEER OF Q RECORD PRIOR TO CONSIRIICIIDN. OF PROPOSED ANTENNA PROPOSED LESSEE(1) APPROXIMATE IAT: N4T 4Y 222' LUET.EV. 10-0 t - ANTENNA 15.1'0 X 24211 COORDINATES LONG: Vf7T Or 01.0' J 2D8'-O"t(AMSu Hudson PROPOSED 5'PT HIGH FIBERGLASS EXTENSION ICECOC vrtn me m IDLE s� - v.ravrte�onu •ALPma.sn TOP OF EXISTING UTILITY POLE - ELEV. 13- t ACl IXISING PRIMARY199'-6't.(AMSC) POWER EXISTING PRIMARY -EXISTING;UTILITY POLE POWER MECO#907 EXISTING SECONDARY r"r" PROPOSED WEATNERHEAD POWER �.."`'�• H DF MISS4 EXISTING UTILITY LINEEXISTING POWER ��. ANIEL P. cy oJ, PROPOSED RI;S CONDOR TO SECONDARY�' METER !._.' _ - - o. cl EXISTING BIER . .41 4 ;x MLE UTUTILITYl ;I PROPOSED IaBFR RI 2' PROPOSED(1)1/2'COAX EXISTING CHECKED ETY: JX, CONDUIT TO2�NA FROM 8101 _ APPROVED BY: DPH Al FIBER PROVIDER O 1�s,A� SUBMITTALS PROPOSED FMER PROPOSED AG/OC CONVERTIR (FROXHINUL�&BACKHAUU ® PROPOSED RGS CONDOR PROPOSED LESSEE 80A PROPOSED LESSEE 8FUSED (I)AWS RRH DISCONNECT&SURGE ARRESTOR PROPOSED LESSMITER O PROPOEEED -+ o aeaYD we Ht7�mor rr sAR-o _ N ANDOVER SC34 3 }IIA O S.TOF(.-) IN ACCORDANCE WITH � IDC ADORE$ UTLITY COMPANY "' REOUIRENEMM S 722 OSFA NORANDOVERER,.MA 01645 HH '"&.'l " b EXLtiTINC 11TRJ1Y a` CROUPA.* POLE MECO 907 sr�T llrtC�.T EIEV.NO�O'-0 3 AGL, I. I, 166'-0't(AMSTJ 'l 1'I"j E .'� ELEVATION & PHOTO PROPOSED ,: GROUND RODAll sRi RrAHlDt GRAPHIC ELEVATION 1 p� Cd EXISTING PHOTO DETAIL 2 L-2 2334 SCALE 3/8"x/-O' L-2 SGV.E:N.TS l-2 11x17 SCALE 3/16'1'-O' LFACG EXHIBIT THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE ANO 1.AN ANALYSIS OF THE CAPACITY OF THE EXISTING m INTENDED TO PROVIDE GENERAL INFORMATION STRUCTURE SUPPORT THE PROPOSED LOADING REGARDING THE LOCATION AND SIZE OF THE HAS NOT BEEN COMPLETED BY HUDSON DEIGN PROPOSED WIRELESS COMMUNICATION UPON FCOMPL THE CROUP,LLC.ORE OF ARE SUBJECT TD CHANGE W SITE LAYOUT WILL BE FINALIZED UPON COMPLETION PENDING OUTCOME OF A STRUCTURAL ANALYSIS. OF SITE SURVE'!AND FACILITY DESIGN. W 2. SHOP DRAWINGS OF FINAL£%TENSION AND/OR I� LU ANTENNA MOUNT TO BE PROVIDED TO ENCMEER OF Q RECORD PRIOR TO CONSTRUCTION, LU Hudson I � EXISTING OVERHEAD) WIRES BELOW PROPOSED LESSEE . s+o c�n�nn�sss (t)AWS RRH .�woFs.waun ue.+la s>a. IfPROPOSED 5'FT HIGH FIBERGLASS EXTENSION .• �' '�. � - PROPOSED LESSEE(1) 9�+T ANTENNA 15,1'0 X 24.2'H t s.t'ego RRH DETAIL PLAN 4 o s 1 z 2 FEET - 22x34 SCALE: 1'-1'-0' L-3 �.LIF dgq _ x 1107 SCALE: 1/2-=r—o• AN'EL P. �✓ 0 w j PROPOSED ANTENNA I , �, o.4 !20 IZZ CHECKED BY: JX SECONDARY APPROVED BY: OPH r PROPOSED I LESSEE(t) A- 'FIBER ANTENNA SUBMITTALS 15.1'ee24.2H FIBER FROHrRkUL CRD. &BACKHAUL m. Ort 0^SPYId u' 3 Q ( I SAR-O c t y5 c �I� oa m/zVn ru 0xc m•f r COMMSCOPE MC-MNf-TOP '..� -; O MOUNTING IOT t N ANDOVER SC34 d •` AL/OC GOHVERTER MA ANTENNA WITHOUT GPs _ mC Aca�a: sM" GOA SERVICE 722 DSGOCO ST •� "' EOU1PMDliT NORTH ANDOVER.MA 01845 �S 7/8'-14 THREADEDFIBERGLASS3 SND FOR ANTI" POLE-TOP �j} o MOUNTWG EXTENSION FIAT WASHER RSO DNR EQUIPMENT DETAILS SMALL CELL GMENHA LOCK WASHER DIMENSIONS.37'Hx111Vx8'D DIMENSIDNS:15.1'0x242' 7/8'-B"a NUT WEIGHT.NS LBS METER SOCKET WEMW..22 LBS 9ttC1 NIA®ER ANTENNA MOUNTING — ANTENNA DETAIL 1 RADIO DETAIL z DETAIL �3 GENERAL WIRING DIAGRAM 5 L-3 SGL£:N.T.S l-3 SCALE L-3 N.T.S SCALE N.T.S l-3 SCALE:N.T.S L-S 982 OSGOOD ST. NORTH ANDOVER, MA 01845 X N ANDOVER SC35 MAtu Q Hudso Lli "©O au as oexvxac nrznr.:.n w�.w+er.auwvs .cr�aa.mr i Vr M,gs'S9 AN El P. o cl + o.4 7 0 �S9ff�CKm 6'�: ,oI APPROVED BY: ow SUBMITTALS •cc e�irr� a aAJP P e /ryn mer r �rac N ANDOVER SC35 MA sm lammm 682 0SMW ST. MOM ANWVVL W OIM sm m= KEY PLAN �� ��� nai■naa N KEY PLA7SN t L-1 r SG(£.N. l-1 �ppamny��c UT. LD *" Orr 1E.E0• 1 R � �COOROCHII6�'� � NG 1Y71'QY 0536' NOTES, ILRSF Fymnwr 1�- 1.AN.ANALYSIS OF Off CAPACITY OF THE DaSIM THIS LEISE PLAN IS DIAGRAMMATIC IN NIOURE AND m STRUCTURE 10 SUPPORT THE PROPOSED LOADING IS INTENDED TO PROWDE GENERA.INFORMATION WAS NOT BEEN 00MPIETBX BY HUDSON DSR! REGIRROING THE LOCATION AND SUE OF TIT X PENDIGROUPNG OUTCOME OF A STRUCTURAL LLC,ORKWINGS ARE SUBJECT ANALYS'TOIS. SITE LAYOUT PROPOSED WILL FINALIZED N COMPLETION OF SITE SURVEY AND FACDJTT DESIGN, A SHOP DRAWINGS OF PROVIDED EDj j N AND/OR ANTENNA RIO RF 10 N PROVIDE TO ENGINEER OF < RECORD PRIOR TO CONsiRUCIfOW (Q COOAPPRDINATEATES: IAA: X4Tw7r 47 OS3r cMrrmATT-s tnru: wir DY ossa• J IJ (•IUCIS011 ..- Gaoupuc® TOP OF PROPOSE ANiQINA -17 t _ mcco¢mrr 179'-11.3(AMSC) �pgSTMG_GU'MARE.,,. A G OF PRai+OSLD 1 ,v F1EK�31'-B•S( PROPOSED LESSEE(1) I //� •• t78'-9'3 V(AUSL)A65L) ANTENNA 12 0 X 2a.7'N TOP OF IM-P UTILITY POLE .R J ELEV.�10-Ot AG m 777'-D•3(AMSC) PROPOSED SECONDARY POWER EIEV.-25-9 i / 17Y-9•f(AMSC) / a�P�jN OF dogs WEkMIERHEAO PROPOSED POWER FROM—"/ a��m� �/ F A m P. �G EXISTING UmTTY POLE MECO 83DO7 ACROSS sr. PROPOSED FIBER FROM f CI EXISTING UiIIDY POLE rmDPosm F BFR ACROSS ST. �EIEV.�19'-0't(ACIPtJCISTINC.,GU.YWIRE ,M 188•-6't.(AMSL) PROPOSED(1)1/2'COAL .�; S57gyp�EtG IN 2'CONDUIT FROM RRH N PROPOSED RGS CONDUIT TO.METER TO ANTENNA n I PROPOSED FIBER IN CHECKED BY: JX c PROPOSED FIBER DEUARC BY 2'U-GWRD J APPROVED BY. DPN FIBER PROVIDER O 15'ACL 9 PROPOSE AC/W CONVERTER PROPOSED FIBER (FRONLNwL a aACRNAILIQ SUBMITTALS PROPOSED RGS CONIUM PROPOSED 1OSED !, ' ExRTNC UTq.ttt POLE �� s PROPOSED LESSEE 80A FUSE f MECO Ig3007 DISCONNECT a SURGE ARRESTOR PROPOSED SAR-O PROPOSED LESSEE METER •1f � wmns u�lu m.ns a � srt NuR s To e'-a•(A� N ANDOVER SC35 IN ACCORDANCE Wfi}I AAA UTUM COMPANY REOUIREVENfs982 OSGGOID y me Aoaus * c o a NO AM YVER.MAT01845 0 �CROUND ' ELEV.�S "o rI2I CmPOM:—ROUND r747'-0•t(AMSC) � RODfl l:, ELEVATION & PHOTO ELEVATION 7 GoePN-�S..S'a q P-4•x'-E' x14 SCALE'3/B'-7'-0' L-2 EXISTING PHOTO DETAIL 2 11SL-2 17at7 SORE 3/76.1'-0' SCALE WTS L-2 LFeCF FYNIM NOTES: THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND 1.AN ANALYSIS OF THE CAPACITY OF THE DOSTING - m IS INTENDED TO PROVIDE GENERAL INFORMATION SRUCIURE TO SUPPORT THE PROPOSED LOADING REGARDING THE LOCATION AND SIZE OF THE HAS NOT DEEM COMPLETED BY HUDSON DESIGN - X PROPOSED WIRELESS COMMUNICA710N FACILITY. THE GROUP,I.I.C.DRAWINGS AitE SUBJECT TO CHANGE W SITE LAYOUT WILL BE FINAUZEO UPON COMPLETION PENDING OUCTU TCOME OF A STRURAL ANALYSIS. PROPOSED LESSEE i OF SITE SURVEY AND FACD.RY DESIGN. (1)AWS RRH 2. SHOP DRAWINGS OF FINAL WENSION AND/OR W ANTENNA MOUNT TO 8E PROVIDED TO ENGINEER OF RECORD PRIOR TO CONSTRUCTION. EXISTING UTILITY POLE• \� ' J MECO#3007 `SOC Hudson ® PROPOSED LESSEE(1) a f, ANTENNA 12'Os28J?I \ O ®a^.,omae.n ux e PROPOSED Y PO PCWER FROM UTILITY POLE a\ ACROSS STREET RRH DETAIL PLAN a SRno..z_:er_elo 12.0'0 — z'z i 22x34 SCALE: 1 lFEET 2--`)'"11x17 SCALE- 1/2"®1'-0' L-3 F`5 S,Sa ANIEL P. MCf�^ OPROPOSED A'VIENNA CI •o.4 720 r N 11. CHECKED BY: UX r' _ PROPOSED LESSEE(1) JF- K_ —�N SECONDARY �I ANTENNA 12.0'ex28.7-M APPROVED BY: DPH FIBER ! I FIBER CRD. SUBMITTALS &aAClat MTr t�utox SAR-00 8 >v T N vdyCOMMSCOPE Op MOUNTINGTMT �rt"5D}NN ANDOVER SC35 ACMA CDMMSCOPE 1 1 60 882 OSGGOD ST. MC—MHT—TSI y( EQNORTHANDOVER, MA 01845 MOUNTING KR =l(ISTINC UTWTYPOLEJ6RADIO UNrr +SMwi CELL ANTENNA EMm.37'Nrtt'Wxsro EQUIDIMESIOSE NH3600S-DG-FOM � 55 LBS OUIENSIONS:72.0'o K 28.7H TTE7GNf1:27 LDS ANTENNA MOUNTING _ SMkEti•NNlflEk ANTENNA DETAIL + RADlO DETAIL 2 DETAIL �� GENERAL WIRING DIAGRAM S L-3 SCALE N.T.S L-3 SCAM N.T.S L-3 SCALE:N,T.S L-3 SCALE N.TS L-3 ' =&"t a 191:4 : , • : .. G f%!.lint l IY •llt,� lKl iIN:l II IIY fent I' rr Y •. ••! VA ao.- Ea P,h d�• Ihti CV1bCR r AN ANALYSIS OF THE CAPACITY OF THE DOSING ANG LEASE PLN 5 6IAGRAMMA=IN NATURE APD m SIRUCRNRE TO SUPPORT DE PROPOSED LOADING IS WrENDED TO PROVIDE GENERAL INFORMATION HAS NOT BEEN COMPLETED BY HUDSON DESIGN REGARDING THE LOCATION AND SIZE OF THE X GROUP.LLC.ORAIRNGS ARE SUBJECT TO CHANCE PROPOSED WIRELESS COEMINICA7ION FACRRY. THE TOP OF PROPOSED ANTENNA PENDING OUTCOME OF A STRUCTURAL ANALYSIS. SITE LAYOUT WILL BE FRW.TIID UPON COMPLETION W -B".-37-a 3 VGQ OF SIVE SURVEY AND FACILITY DESIGN. uj 268'-6.3"SL) N ELEV.TOF 30 M. ENt1AHTA __ PROPOSED LESSEE(1) APPRDXNATE LAT. N42 39'42.17' J ELEV.-TDP OF DfISTiNc llI1LIIY PO zaANTENNA 16.tY X 242•H CDORDIIATM' LDNG-- Mt'Ca'3554' MOUNT ®p PRSED g15TOY ® . TNC LE PROPOO Hu&on ELEV.-29'-0'*!(AAM 266'-0't(AMSC) acn am ' xmxcH=iawrr_nwsxm IC Prn_sxvm EXISTING POWER Kn+oaax u.,lw ncrmav,n� i EXISTING GUY WIRE - PROPOSED WFATHERHEAD PROPOSED FIBER (TED) PROPOSED(1)1/2-COAX IN Y CONDUIT FROM RRH EXISTING GUY WIRE TO ANTENNA , Lt P��N OF V4S'('4' EXISTING Inns UTRRY POLE AN EL P. KGs .H I PROPOSES FIBER W Y UUi o.4 7 0 i CONDUIT n o �STES�0\•aE4. .H USED RCS CONDUIT R PROPOSED FIBER PROPOSED AC/DC CONVERTER (FRONTNAUL @ BACKWWy - f CHECKED BY: U% PROPOSED LESSEE (.. APPROVED SV DPH PROPOSED RGS CONDUIT (1)ANS RRH - r SUBMITTALS I PROPOSED Umm GOA Rm DISCONNECT @ SURGE ARRESTOR PROPOSEDUSSEE METER PROPOSED O sAR-0 ,`i +`.Wi r yid + s Dy r j, f NORTH ANDOVER MA IN ACCORDANCE WITH 1S. ,""q t; )%�. . w CRAN20 UTILITY COMPANY REQUIREMENTS >m Acox� 740 TURNPIKE ST. * NORTH ANDOVER MA DIM 0 G uND LEVEL. .rte• ks "�" Wi�. 9Ra TRYT ELEv. 237-D'i(AMSC) I -il I Mill'I Cl� :�- , / + , �Il�a ' IInpx� ", .. '� ELEVATION 8c PHOTO GROUND ROD ELEVATION 1 f.D.p•+P•e_r.�e �, __�TEE'T SCA ETiNG PHOTO DETAIL x L-2 22x34 SCALE 1/2-1-0• L-2 SCALE N.TS L-x 11x77 SCALE 1/4"-1'-0' t cecF FYNIRrt yGg: F THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND AN ANALYSIS OF THE CAPACITY OF THE DOSITNG m 6 INTENDED TO PROVIDE GENERAL INFORMATION STRUCTURE TO SUPPORT THE PROPOSED LOADING REGARDING THE LOCATION AND SIZE OF THE HAS NOT BEEN COMPLETED BY HUDSON DESIGN PROPOSED WREIESS COMMUNICATION FACILITY. THE GROUP,LLC,DRAWINGS ARE SUBJECT TO CHARGE SITE SIE LAYOUT WILL BE FINALIZED UPON COMPLETION PENDING OUTCOME OF A STRUCTURAL ANALYSIS. LV OF SITE SURVEY AND FACILITY DESIGN. LLI EXISTING OVERHEAD DDSTING vnLTP!POLE N 'ARES BELOW /1515 Q LU PROPOSED LESSEE(1) J ANTENNA 15.1'0 x 24.2°H Hudson®® 'b 1 PROPOSED LESSEE (1)AWS RRH 75.1"0 j 77T 14.52• = U y��a i&Uao RRH DETAIL PLAN a D 5 CRA__PNK�5"t'•�c ' FEET ` x I"- 23x34 SCALE: t'-t'-0' l-3 OF PROPOSED LESSEE(1) J1 11x17 SCALE: 1/2'-1'-O' � EtiS ANTENNA 15.1.0 x 24.2'H f o ?A,NIa P. PROPOSED ANT-.ML 7 0 I I � 1STE `4� t CHECKED BY: —� 4SECONDARY APPROVED BY: DPH FBEa SUBMITTALS i k a,BA FRONTHAUL CRO, Nu :Ax ntrA rn 1 � � &BACKHAUL c SAR-0 c u E6 / PROPOSED CUSTOM MOUNT J lu �? a H/10/:�IaI tuu pMmt u+ ArnENNA wmor cPs 1 NORTH ANDOVER MA b AC/DC CONVERTER CRAN20 j� II I• I�Ij i zR Aarsss: I I 60A SER ICE 740 TURNPIKE ST. �S L 7/8'-14 THREADED '`I (I ILII IIII� I EOIRPM.ENT NORTH ANDOVER,MA 01845 3 STUD FDR ANTENNA I I I I I I o _ FLA�TWASHER I I I I I I ( e 1 LOCK WASHER ENSI cEll W4,2 RADIO uNlr I I ILII I( I I EQUIPMENT DETAILS DIMENSIONS:15.1'9x242' 7/B'-9 HIX NUT DtlAENSIONS`.37'HAt 1'Wt6"D PETER SOCKET WEIGHT:22 LBS WEICFff:18 LBS I 1 I I I 10, Ex11S7NG UTII.IIY POLE s etT Mwsm ANTENNA MOUNTING — ANTENNA DETAIL �� RAD lO DETAIL �z� DETAIL 3 GENERAL WIRING DIAGRAM 5 L-3 SCALE N.TS L-3 SCALE N.T.S LL-J SCALE:N.T.S l-3 SCALE:N.T.S L-3 WIRECON-01 TELLIS ACOROw DATE(MMIDD/YYYY) CERTIFICATE OF LIABILITY INSURANCE 9/16/2015 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: Norton Insurance Agency PHONE FAX 275 US Route 1 AIC No Ext:(207)829-3450 AIC No): (207)829-6350 Cumberland Foreside,ME 04110 ADDRESS: INSURER(S)AFFORDING COVERAGE NAIC# INSURER A:Maine Employers Mutual Ins. 11149 INSURED INSURER B:MEMIC Indemnity Wireless Construction,Inc INSURERC: 40 Blake Road INSURER D: Standish,ME 04084 INSURER E INSURER F: _ COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR I TYPE OF ISRANCE ADDL BR POLICY EFF POLICY EXP NU LTR INSD WVD POLICY NUMBER MMIDD/YYYY MMIDD/YYYY LIMITS COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ CLAIMS-MADE r_1 DAA D PREMISES Ea occurrence $ MED EXP(Any one person) $ PERSONAL 8 ADV INJURY $ GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ POLICY❑ PRO JECT F-1 LOC PRODUCTS-COMP/OP AGG $ OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ Ea accident ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED tid P BODILY INJURY(Per accident) $ AUTOS AUTOS ( ) HIRED AUTOS NON-OWNED PROPERTY DAMAGE $ AUTOS Per accident UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED I I RETENTION$ $ WORKERS COMPENSATION X PER I OTH- AND EMPLOYERS'LIABILITY STATUTE ER A ANY PROPRIETOR/PARTNER/EXECUTIVE YIN 1810097681 09/19/2015 09/19/2016 E.L.EACH ACCIDENT $ 1,000,000 OFFICER/MEMBER EXCLUDED? N/A (Mandatory in NH) E.L.DISEASE-EA EMPLOYE $ 1,000,000 If Yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 1,000,000 B Workers Compensation 5101800218 09/19/2015 09/19/2016 NH,VT,CT,MA 1,000,000 DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Douglas Wright,Stanley Brown,&Michael Sullivan are excluded from Workers Compensation as permitted by statute. It is the insured's intent to provide a Waiver of Subrogation on the policies indicated in the column above when required by written contract only if the insured is awarded the contract. With respect to the Waiver of Subrogation,a 30 day notice of cancellation will apply in favor of Verizon Wireless. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Verizon Wireless THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. 400 Friberg Parkway Westborough,MA 01581 AUTHORIZED REPRESENTATIVE ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD • The Commomvealth of Massachusetts Department of Industrial Accidents Office of Investigations '. 600 Washington Street Boston,MA 02111 ' www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name(Business/Organization/Individual): WIRELESS CONSTRUCTION, INC. Address: 40 BLAKE ROAD,STANDISH, ME 04054 City/State/Zip: STANDISH, ME 04034 Phone#: 207-642-5751 Are you an employer?Check the appropriate boa: Type of project(required): 1.❑x I am a employer with 50 4. ❑ I am a general contractor and I employees(full and/or part-time). have hired the sub-contractors 6. ❑New construction 2.❑-1 am a sole proprietor or partner- listed on the attached sheet. 7. ❑Remodeling ship and have no employees These sub-contractors have g. ❑Demolition working for me in any capacity. employees and have workers' 9. ❑Building addition [No workers' comp.insurance comp.insurance.t required.] 5. ❑ We are a corporation and its 10.0 Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.❑Plumbing repairs or additions myself. [No workers'comp. right of exemption per MGL 12.❑ Roof repairs insurance required.]t c. 152,§1(4),and we have no employees. [No workers' 13.❑ Other comp.insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. f Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. $Contractor that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp,policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: Maine Employers Mutual Itis. Policy#or Self-ins. Lic.#: 5101800218 Expiration Date: 09/19%2016 Job Site Address: N/A City/State/Zip: N/A Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the painsandpenalties of perjury that the information provided above is true and correct Si attire: a l Date: Phone Official use only. Do not write in this area,to be completed by city or town official City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person• Phone#• IM Massachusetts-Department of Public Safety Board of Building Regulations and Standards Construction SuperAisor License: CS-103000 KYLE W PURIN4;4'ON ' 31 Morse Cemeteiy Roa Greene ME 04239 Expiration Commissioner 09/14/2016 i r 521 =623 DALE STREET, NORTH AMA 01845 X1 N ANDOVER SC15 MA W ch LLJa Hudson Design Groupuc 1600 OSGOOD SIREEI BUILDWG 20 NORM,5lNE 3090 TEL:19781557-&W N.ANDOVER,MA01845 FAX:1978)336-5586 0 O < 'ANJEl P. yG� • 0 ml 1 J -� o.4u zu CHECKED BY: JX • APPROVED BY: DPH 0 ► *` SUBMITTALS raEv. DATE oEsaePnaN Br • 0 07/22/16 IEISE Dwsrt CP SITE NAME ' N ANDOVER SC15 f MA .�., _ • SfTE ADDRESS: '= 521-623 DALE STREET NORTH ANDOVER, MA 01845 o r •• SHEET 7mE KEY PLAN 14 53' Uj m§ w A Z SHEET NUMBER N KEY PLAN 1 _ SCALE: N.T.S L-1 APPROXIMATE LAT: N47 41' 06.2" 6)k COORDINATES: LONG: W71' 04' 49.5" NOTES LEASE EXHIBIT r 1. AN ANALYSIS OF THE CAPACITY OF THE EXISTING THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND m STRUCTURE TO SUPPORT THE PROPOSED LOADING IS INTENDED TO PROVIDE GENERAL INFORMATION HAS NOT BEEN COMPLETED BY HUDSON DESIGN REGARDING THE LOCATION AND SIZE OF THE GROUP, LLC. DRAWINGS ARE SUBJECT TO CHANGE PROPOSED WIRELESS COMMUNICATION FACILITY. THE W PENDING OUTCOME OF A STRUCTURAL ANALYSIS. SITE LAYOUT WILL BE FINALIZED UPON COMPLETION 2. SHOP DRAWINGS OF FINAL EXTENSION AND/OR OF SITE SURVEY AND FACILITY DESIGN. W ANTENNA MOUNT TO BE PROVIDED TO ENGINEER OF Q RECORD PRIOR TO CONSTRUCTION. APPROXIMATE LAT: N47 41' 06.2" W COORDINATES: LONG: W71' 04' 49.5" J TOP OF PROPOSED ANTENNA ELEV.= 38'-0 t AGL Hudson 232'-0-f (AMSL) , Design Gr0Upuc D kS OF PROPOSED EN ANTNAt- ELEV.= 37'-0-t (AGL) PROPOSED LESSEE (1) '- 231'-0.3 (AMSL) ANTENNA 15.1'0 X 24.2"H _ y• i y I600 OSGOOD STREET ST IM RY POWER a f - BUILDING 20 NORTH,SURE 3090 TEL(978)557-5553 N.ANDOVER,MAOI Bas FAX:(9781336.5586 I !f y (EXISTING GUY WIRE 1 w PROPOSED 5'-0"H FIBERGLASS `t EXTENSION - EE E r,. 1f 4 t, 1, i. EXISTING SECONDARY POWER . hTOP OF EXISTING UTILITY POLE At ' 11 �ELEV.= 3 0':_ (AGL) ± 224'-6"t (AMSC) EXISTING PRIMARY POWER /`_ x„EXISTING CABLE ' PROPOSED WEATHERHEAD - - -- �' EE�E � `-EXISTING SECONDARY POWER EXISTING GUY WIRE EXISTING CABLE EXISTING TELCO r \J,` EXISTING FIBER d lo.4J7i� .. .�-•a`r`� � �, � i��' ,. -p�Lv ,pct H EXISTING TELCO �� A c cPROPOSED (1) 1/2- COAX PROPOSED FIGS CONDUIT TO METER IN 2- CONDUIT FROM RRHCHECKED BY: JX n TO ANTENNA } PROPOSED FIBER IN "� �' APPROVED BY: DPH F PROPOSED FIBER DEMARC BY 2” U-GUARD EXISTING UTILITY POLE + ` FIBER PROVIDER O 15' AGL MECO //1460 SUBMITTALS O r, PROPOSED AC/OC CONVERTER PROPOSED FIBER KV. DATE OESOWTI011 ITT (FRONTHAUL & BACKHAUL) PROPOSED FIGS CONDUIT PROPOSED LESSEE (1) AWS RRH - PROPOSED LESSEE 60A FUSED PROPOSED SAR-0 DISCONNECT & SURGE ARRESTOR .- PROPOSED LESSEE METER ' � o m/zz/1s LEASE MWca W 9L SITE NAME: 'a N ANDOVER SC15 W EXISTING UTILITY POLE MA 5' TO 8'-6- (AGC) MECO #1460 m SITE ADDRESS: IN ACCORDANCE WITH 521-623 DALE STREET UTILITY COMPANY NORTH ANDOVER, MA 01845 REQUIREMENTS a O tiGROUND LEVEL ": - _:` -. '�- .�;,M� SHEET TITLE ELEV. = 0'-0"t (AGL) a ELEVATION & PHOTO 194'-0"t (AMSL) - -41 PROPOSED GROUND ROD ' . SHEET NUMBER ELEVATION 1 GRAPHIC SCALE 1'-4" 2'-8" 5'-4" 8'-0" L-2 n 22x34 SCALE: 3/8"=1'-0" L-2 �EXISTING PHOTO DETAIL 2 G 11x17 SCALE: 3/16"-1'-O" SCALE: N.T.S L-2 LEASE EXHI8d NOTES: THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND 1. AN ANALYSIS OF THE CAPACITY OF THE EXISTING m PROVIDEIS INTENDED TO REGARDING THE LOCATION AND GENERAL ZE NOF THE TION �UNOT RBEEN COMPLETED BY HUDSON DESIGNG PROPOSED WIRELESS COMMUNICATION FACILITY. THE GROUP, LLC. DRAWINGS ARE SUBJECT TO CHANGE x SITE LAYOUT WILL BE FINALIZED UPON COMPLETION PENDING OUTCOME OF A STRUCTURAL ANALYSIS. W OF SITE SURVEY AND FACILITY DESIGN. W 2. SHOP DRAWINGS OF FINAL EXTENSION AND/OR "H '-O ANTENNA MOUNT TO BE PROVIDED TO ENGINEER OF PROPOSED 5 (n RECORD PRIOR TO CONSTRUCTION. FIBERGLASS EXTENSION Q W J Hudson Design Groupuc 9 � I c j 1600 OSGOOD STREET BUILDING ZO NORiH,SURE 3090 TEL 19781 557-5553 N.ANDOVER,MA 01845 FAX:19781336-5586 EXISTING OVERHEAD oN WIRES BELOW pN� PROPOSED LESSEE (1) /av ANTENNA 15"044.2"1-1 a" PROPOSED LESSEE (1) AWS RRH 1453' lit ~ p GRAPHIC SCALE z RRH DETAIL PLAN 4 0 .5 1 2 3 TEEr Jlj 2204 SCALE: 1"=l'-O' L-3 11x17 SCALE: 1/2"=1'-0" \� ^✓Gq, •, +� o i M111EL F. ,• �I � MM « PROPOSED ANTENNA J . I - IO.4J7LJ CHECKED BY: JX PROPOSEDeo m SECONDARY N + LESSEENA(1) — N JAPPROVED BY: DPH 4, IANTE 15.1"0x24.2"H eFIBER SUBMITTALS FIBER FRONTHAUL GRD. & BACKHAUL w REV. 14TE of DwnoN BY SAR-0 p c� lb +" U N r > Cr COMMSCOPE a-� MC-MNT-TOP a a o m/zz/Ts Dow DIP 1 O MOUNTING KIT N o +�.I JERTER SITE NAMEANTENNA WITHOUT GPS ; N ANDOVER SC15 AC/DC CONVMA SITE ADDRESS: z ±<@D > 0\ 11-71 60A SERVICE 521-623 DALE STREET 7/g"-14 THREADEpFIBERLASS EQUIPMENTNORTH ANDOVER, MA 01845 STUD FOR ANTENNA POLE-TOP MOUNTING EXTENSIONFLAT WASHERSHEET TITLE LOCK WASHER RADIO UNIT SMALL CELL CANTENNA DIMENSIONS: 37"Hx11'Wxs"D EQUIPMENT DETAILS DIMENSIONS: 15.1"0x24.2" 7/8"-9 HEX NUT WEIGHT: 55 LBS WEIGHT: 22 LBSMET SHEET NUMBER ANTENNA MOUNTING = ANTENNA N EENNS DETAIL L 13 RADIO DS TAIL L23 DETAIL S L33 GENERAL WIRING DIAGRAM L53 L_3 H 521 =623 DALE STREET NORTH ANDOVER MA 01845 X N ANDOVER SC15 IIIA W cn a J Hudsonj. Design Groupuc 1600 01GOOD STREET BUILDNG 20 NORTH,SURE 3090 TEL:X978)557-5553 N.ANDOVER,MA 0IBd5 FA%:�978�336.5586 Q O , �O O -•-• . G L ANIEL P. tiG I a4J7L0 CHECKED BY: JX • APPROVED BY: DPH Q � SUBMITTALS stv. a>E I oEsaaarrorr BY xl• .. 0 07/22/15 LEA&MW CP SLTE NAME: N ANDOVER SC15 MA A SrrE ADDRESS: 521-623 DALE STREET NORTH ANDOVER, MA 01845 o •• `�.. SHEET TRLE KEY PLAN 1144 �_� i W m0 �Z �r:Z SHEET NUMBER N KEY.PLAN 1 SCALE: N.T.S L-1 APPROXIMATE LAT: N42' 41' 06.2" COORDINATES: LONG: W71' 04' 49.5" NOTES.; I FAQF t 3tularr 1. AN ANALYSIS OF THE CAPACITY OF THE EXISTING THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND m STRUCTURE TO SUPPORT THE PROPOSED LOADING IS INTENDED TO PROVIDE GENERAL INFORMATION HAS NOT BEEN COMPLETED BY HUDSON DESIGN REGARDING THE LOCATION AND SIZE OF THE X GROUP, LLC. DRAWINGS ARE SUBJECT TO CHANGE PROPOSED WIRELESS COMMUNICATION FACILITY. THE PENDING OUTCOME OF A STRUCTURAL ANALYSIS. SITE LAYOUT WILL BE FINALIZED UPON COMPLETION W OF SITE SURVEY AND FACILITY DESIGN. W 2. SHOP DRAWINGS OF FINAL EXTENSION AND/OR ANTENNA MOUNT TO BE PROVIDED TO ENGINEER OF Q RECORD PRIOR TO CONSTRUCTION. APPROXIMATE LAT: N47 41' 06.2" W COORDINATES: LONG: W71' 04' 49.5' J ELEV TOP OF PROPOSED ANTENNA t Hudson D .= 38—0 AGL 232'-0"t (AMSL) a r ; r fi r _ Design Groupuc -0.��F ELEV.= 37'-0't (AGL) PROPOSED LESSEE (1) (jj 231'-0't (AMSL) ANTENNA 15.1"0 X 24.2"H �.. j ;/' 16MOSGOOD STREET i 3 / EXIIS ,RY POWER X � BUILDING 20 NORTH,SURE 3090 TEL(978)557-5553 N. rtl 7,i '. ` N.ANDOVER,MA 01845 FAX:1978)336-5586 C I EXISTING GUY WIREto I PROPOSED 5—0.H FIBERGLASS 'r EXTENSION A E E E —� ' R ,i1. �} EXISTING SECONDARY POWER TOP OF EXISTING UTILITY POLE ay t �ELEV.= 30'-6"t (AGL) EXISTING PRIMARY POWER 'S :� LE 224'-6"t (AMSL) EXISTING CAB ,,, PROPOSED WEATHERHEAD - — E E E ;" r �, EXISTING FIBER STING SECONDARY POWER j 0 �� ��i EXISTING GUY WIRE I J EXISTING CABLE n • �- \' I AINILL P. G r ' EXISTING TELCO s cI'J EXISTING FIBER =i r" a ' FC/.STS, ., ;I EXISTING TELCO - �A)AL �`>G• 0„s° o PROPOSED RGS CONDUIT TO METER —PROPOSED (1) 1/2' COAX T, CHECKED BY: JX IN 2' CONDUIT FROM RRH rll TO ANTENNA �F PROPOSED FIBER IN APPROVED BY: DPH H 2" U—GUARD v.: ' PROPOSED FIBER DEMARC BY EXISTING UTILITY POLE FIBER PROVIDER O 15' AGL MECO #1460 , I SUBMITTALS 0 M PROPOSED AC/DC CONVERTER PROPOSED FIBER +x atE (FRONTHAUL & BACKHAUL) PROPOSED RGS CONDUIT PROPOSED LESSEE (1) AWS RRH PROPOSED LESSEE 60A FUSED PROPOSED SAR-0 DISCONNECT & SURGE ARRESTOR PROPOSED LESSEE METERO a 07/22/15 LEASE DHBIT CP LU d SITE NAME: 01 N ANDOVER SC15 EXISTING UTILITY POLE p MA MECO #1460 5' TO 8'-6' (AGL) m ' SITE ADDRESS: IN ACCORDANCE WITH 521-623 DALE STREET REQUIREMENTS UTCOMPANY NORTH ANDOVER, MA 01845 v i O tiGROUND LEVEL x,^ . -._.__, SHEEP TITLE ELEV. = 0'-0"t (AGL) 1 194'-0"t (AMSL) SII!I, I II II—I1- , ELEVATION & PHOTO I I� � , II �_I . PROPOSED GROUND ROD SHEET NUMBER ELEVATION 1 GRAPHIC SCALE 22x34 SCALE: 3/8"=1'-0' L-2 0 1—a" 2—a° s'-4' a'—o' EXISTING PHOTO DETAIL 2 L-2 11x17 SCALE: 3/16"=1'—O" SCALE: N.T.S L-2 LEASE EXHIBR NOTES; THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND 1. AN ANALYSIS OF THE CAPACITY OF THE EXISTINGIS INTENDED TO PROVIDE m REGARDING THE LOCATION AND GENERAL ZINFORMATION E OSTRUCTURE HAS NOTRBEEN COMPLETED BY HUDSON DESN LOADING �j`vR��� PROPOSED WIRELESS COMMUNICATION FACILITY. THE GROUP, LLC. DRAWINGS ARE SUBJECT TO CHANGE x SITE LAYOUT WILL BE FINALIZED UPON COMPLETION PENDING OUTCOME OF A STRUCTURAL ANALYSIS. �Q' W OF SITE SURVEY AND FACILITY DESIGN. W 2. SHOP DRAWINGS OF FINAL EXTENSION AND/OR " '-0H ANTENNA MOUNT TO BE PROVIDED TO ENGINEER OF PROPOSED 5cn RECORD PRIOR TO CONSTRUCTION. FIBERGLASS EXTENSION a W J Hudson D Design GroupLLC 7 T 1 I 1600 OSGOOD STREET BUILDING 20 NORTH,SURE 3090 TEL(978)557-5553 N.ANDOVER,MAO 1845 FAX:(978)336-5586 EXISTING OVERHEAD O" ` WIRES BELOW O" '� PROPOSED LESSEE (1) ANTENNA 15"044.2"H O" PROPOSED LESSEE (1) AWS RRH 1453' • -,, _ \_115.1"O :' y p GRAPHIC SCALE �6z4 w z RRH DETAIL PLAN 4 0 .5 1 2 3 FEEL ,N' 22x34 SCALE: 1"=l'—O" L-3 I 11x17 SCALE: 1/2"=1'-0" ` iF » C C'A`JIr F'. /gin PROPOSED ANTENNA I l0 4 )7i CHECKED BY: JX C-4 PROPOSED m SECONDARY 4 LEESSEENA(1) 2 — ?N APPROVED BY: DPH 15.1"0x24.2"H eFIBER SUBMITTALS FIBER FRONTHAUL GRD. fi. & BACKHAUL Uj REV' DE oMCwPnox ar 3 a$ SAR-0 p Z, 04 ' COMMSCOPE /zz/ MC—MNT—TOP N j o m Ts terse DINSr cr NJ tjI� O MOUNTING KIT _Tn ,.. s SITE NAME: ANTENNA WITHOUT GPS N ANDOVER SC15 AC/DC CONVJERTER MA , z SITE ADDRESS: -� Z I 60A SERVICEo 521-623 DALE STREET 7/B'-14 THREADED FIBERGLASS EQUIPMENT NORTH ANDOVER, MA 01845 STUD FOR ANTENNA POLE—TOP MOUNTING EXTENSION_ CL FIAT WASHERSHEET TRUE LOCK WASHER RADIO UNI MALL CELL CANTENNA DIMENSIONS: 37'Hx11"Wx8"DEQUIPMENT DETAILS. DIMENSIONS: 15.1"0x24.2" 7/S -9 HEX NUT WEIGHT: 55 LBS WEIGHT: 22 LBS — METOCKE SHEET NUMBER ANTENNA MOUNTING = ANTENNA DETAIL 1 RADIO DETAIL 2 DETAIL 3 GENERAL WIRING DIAGRAM / 1 L-3 SCALE: N.T.S L-3 SCALE: N.T.S L-3 SCALE: N.T.S L-3 SCALE: N.T.S L-3 1-- 250=336 S. BRADFORD ST, NORTH ANDOVER , MA 01845 x NORTH ANDOVER SC16 MA W cn a w Hudson � Design GToupuc 1600 OSGOOD STREET '"+ BUIl01NG ZO NORTH,SURE 3090 TEL:�978�557-5553 N.ANDO`7ER.MA OI815 FAXa978�336-5586 I� Ak e n y Ir ,r t _ x • CHECKED BY: JX APPROVED BY: DPH .• � SUBMITTALS I•:V. DME o ar r OO o /23/2Dl LksE DHOff a SrrE NAME., NORTH ANDOVER nlw SC16 MA SffE ADDRESS: ,i 250-336 S. BRADFORD ST. r a NORTH ANDOVER. MA 01845 -. ,� �'' y� .�. U O O •• SHEET TITLE a✓T KEY PLAN =1�45�'3�''W ) :3� ZD Z�f5 0 z SHEET NUMBER N KEY PLAN SCALE: N.T.S L-1 APPROXIMATE LAT: N42' 41' 24.58" ` COORDINATES: LONG: W71' 04' 29.01" Ngm LEASE EXHIBIT AN ANALYSIS OF THE CAPACITY OF THE EXISTING THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND m STRUCTURE TO SUPPORT THE PROPOSED LOADING IS INTENDED TO PROVIDE GENERAL INFORMATION HAS NOT BEEN COMPLETED BY HUDSON DESIGN REGARDING THE LOCATION AND SIZE OF THE X GROUP, LLC. DRAWINGS ARE SUBJECT TO CHANGE PROPOSED WIRELESS COMMUNICATION FACILITY. THE W PENDING OUTCOME OF A STRUCTURAL ANALYSIS. SITE LAYOUT WILL BE FINALIZED UPON COMPLETION OF SITE SURVEY AND FACILITY DESIGN. W APPROXIMATE LAT: N47 41' 24.58" W COORDINATES: LONG: Ill 04' 29.01" J Hudson D Design Grotl 1600 OSGOOD STREET BUILDING 20 NORTH,SUITE 3090 TEL:197815575553 N.ANDOVER,MA 01845 FAX:197813365586 TOP OF PROPOSED ANTENNA = 187'-0"t (AMSL) BOE PROPIl ANTEyyg_ _ PROPOSED LESSEE (1) El".- 31'-0"t (AGL) ANTENNA 15.1"0 X 24.2H EXISTING UTILITY POLE 186'-0"t (AMSC) ,MECO #31 PROPOSED CUSTOM MOUNT TOP OF EXISTING UTILITY POLE ELEV.= 29'-6"t (AGL) I 184'-6"t (AMSL) PROPOSED WEATHERHEAD PROPOSED POWER FROM EXISTING UTILITY POLE MECO #30 LOCATED ACROSS THE STREET EXISTING UTILITY LINE /� EXISTING UTILITY LINE EXISTING UTILITY LINE PROPOSED FIBER FROM EXISTING UTILITY POLE) EXISTING UTILITY LINE MECO #30 LOCATED ACROSS THE STREET EXISTING UTILITY LINE__! EXISTING GUY WIRE } �i 'y M G EXISTING GUY WIRE CHECKED BY: JX PROPOSED (1) 1/2" COAX IN 2- _H CONDUIT FROM RRH TO ANTENNAa { PROPOSED RGS CONDUIT TO METER , APPROVED BY: DPH M1 * PROPOSED FIBER IN o 2" U-GUARD PROPOSED FIBER DEMARC BY +I FIBER PROVIDER O 15' AGL \ SUBMITTALS M 0 I PROPOSED FIBER ,`-. " REV' °"N oElimpri0N fff b PROPOSED AC/DC CONVERTER N (FRONTHAUL de BACKHAUL) PROPOSED RGS CONDUIT PROPOSED LESSEE (1) AWS RRH EXISTING 3"0 x 3'-6" PIPE PROPOSED SAR-0 PROPOSED LESSEE 60A FUSED r DISCONNECT do SURGE ARRESTOR J y' o / /�T W PROPOSED LESSEE METER s - ®�I r , � _ SITE NAME, NORTH ANDOVER w EXISTING SIGNS IL (TO BE RELOCATED SC1 E MA AS NEEDED) 5' TO 8'-6" (AGL) ''' IN ACCORDANCE WITH UTILITY COMPANY REQUIREMENTS .. ( SITE nooREss: is � � 250-336 S. BRADFORD ST. " NORTH ANDOVER, MA 01845 S EXISTING UTILITY rr it POLE MECO #31 GROUND LEVEL p e SHEET TITLEELEV. 0'-O"t (AGL) 1� ELEVATION & PHOTO PROPOSED GROUND ROD SHEET NUMBER ELEVATION �� GRAPHIC SCALE 22x34 SCALE: 3/8"=1'-0" L-2 Q 1-a' 2-s• 5-4" s-a" EXISTING PHOTO DETAIL 2 L-2 11x17 SCALE: 3/16"=1'-0" SCALE: Ill L-2 LEASE EXHIBIT N Qi zp THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND AN ANALYSIS OF THE CAPACITY OF THE EXISTING ,/ m IS INTENDED TO PROVIDE GENERAL INFORMATION STRUCTURE TO SUPPORT THE PROPOSED LOADING \� EXISTING OVERHEAD / REGARDING THE LOCATION AND SIZE OF THE HAS NOT BEEN COMPLETED BY HUDSON DESIGN WIRES BELOW PROPOSED WIRELESS COMMUNICATION FACILITY. THE GROUP. LLC. DRAWINGS ARE SUBJECT TO CHANGE x SITE LAYOUT WILL BE FINALIZED UPON COMPLETION PENDING OUTCOME OF A STRUCTURAL ANALYSIS. W OF SITE SURVEY AND FACILITY DESIGN. W PROPOSED LESSEE (1) AWS RRH EXISTING OVERHEAD V) WIRES BELOW Q W J PROPOSED LESSEE (1) EXISTING OVERHEAD Hudson p ANTENNA 15'0x24.2"H yo WIRES BELOW Design Group= EXISTING UTILITY POLE 160003GNG 20 GREE RTH(� TEL:f9781 557-5553 MECO #31 \ \ NU1ANiDOVER.MA 01845SURE 3090 FAX:(978)3365586 Awl O 14!53 15.1'0 z RRH DETAIL PLAN 4 D 5 GRAPHIC SOLE 3 FEET d.M1 1 K 22x34 SCALE: 1"=1'-0" L-3 1107 SCALE: 1/2"=1'-0" L " + • e PROPOSED ANTENNA f PROPOSED LESSEE 1 ( ) CHECKED BY: JX C-4 ANTENNA 15.1'0 X 24.2"H 0 SECONDARY N N APPROVED BY: DPH FIBER SUBMITTALS FIBER FRONTHAUL GRD. & BACKHAUL � REV• are DEsclarnon er 3 s i SAR-0 92 ,r a s > .w f CN +. 1 a. 0 FASE E1/23/201 IM is •Iy.i 1 d N N w' " PROPOSED CUSTOM SIM NAME ANTENNA WITHOUT GPS �; x MOUNT JERTER NORTH ANDOVER AC/DC CONVSC16 MA Z SITE ADDRESS: 60A SERVICEo 250-336 S. BRADFORD ST. EQUIPMENTwNORTH ANDOVER, MA 01645 7/8'-14 THREADEDSTUD FOR ANTENNA ( I EXISTING UTILITY POLE MOUNTINGMECO #31 FIAT WASHER SHEET TITLE LOCK WASHER RADIO UNITEQUIPMENT DETAILS SMALL CELL CANTENNA DIMENSIONS: 37'Hx11'Wx6"0DIMENSIONS: 15.1"0x24.2" 7/8"-9 HEX NUT WEIGHT: 55 LBS WEIGHT: 22 LBS — . ME SHEET NUMBER ANTENNA MOUNTING —� ANTENNA DETAIL 1 RADIO DETAIL a DETAIL 3 GENERAL WIRING DIAGRAM 5 SCALE: N.T.S L-3 SCALE: N.T.S L-3 SCALE: N.T.S L-3 SCALE: N.T.S L-3 H 250=336 S. BRADFORD ST, NORTH AMA01845 xl NORTH ANDOVER SC16 MA w cn a w _ J Hudson � Design Groupuc t 1600 0SGOOD STREET ^� BUILDING 20 NORTH,SUITE 3090 TEL:(978 557-5553 N.ANDOVER,MA 01845 FAX:�978)3365596 '• lilt`i w i " t ° S � r • CHECKED BY: JX •'• • APPROVED BY: DPH .• _ . SUBMITTALS �{ REV. ELATE I U6CPoPN7N BY a >s _ b G� �e o /v/ter E:•OBf as . t �'',T , •..+�"E' x O SrrE NAME: NORTH ANDOVER -}` SC 16 MA SITE ADDRESS: 250-336 S. BRADFORD ST. „• C7 NORTH ANDOVER, MA 01845 s } a v w a o •• SHEET TITLE KEY PLAN =145'3'W Z� Z SHEET NUMBER N KEY PLAN 1 SCALE: N.T.S L-1 APPROXIMATE LAT: N47 41' 24.58' `— COORDINATES: LANG: W71' 04' 29.01' LEASE EXHIBIT = AN ANALYSIS OF THE CAPACITY OF THE EXISTING THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND m STRUCTURE TO SUPPORT THE PROPOSED LOADING IS INTENDED TO PROVIDE GENERAL INFORMATION HAS NOT BEEN COMPLETED BY HUDSON DESIGN REGARDING THE LOCATION AND SIZE OF THE GROUP, LLC. DRAWINGS ARE SUBJECT TO CHANGE PROPOSED WIRELESS COMMUNICATION FACILITY. THE W PENDING OUTCOME OF A STRUCTURAL ANALYSIS. SITE LAYOUT WILL BE FINALIZED UPON COMPLETION OF SITE SURVEY AND FACILITY DESIGN. W U) APPROXIMATE LAT: N4Y 41' 24.58" W COORDINATES: LONG: W71' 04' 29.01" J Hudson *D Design Groupuc 1600 OSGOOD STREET BUILDING 20 NORTH,SUITE 3090 TEL:197815575553 N.ANDOVER,MA 01845 FAX:19781336-5586 TOP OF PROPOSED ANTENNA = 2- t L 187'-0"f (AMSL) E PROPOSED-ANTENN _ _ PROPOSED LESSEE (1) ELEV.= 31'-0"f (AGL) ANTENNA 15.1"0 X 24.2'H EXISTING UTILITY POLE 186'-0"f (AMSL) PROPOSED CUSTOM MOUNT MECO X31 TOP OF EXISTING UTILITY POLE ELEV.= 29'-6"t (AGL) 1 184'-6"t (AMSL) PROPOSED WEATHERHEAD .1 \ 5 PROPOSED POWER FROM EXISTING UTILITY POLE MECO X130 LOCATED ACROSS THE STREET EXISTING UTILITY LINE /�__ EXISTING UTILITY LINE , EXISTING UTILITY LINE PROPOSED FIBER FROM EXISTING UTILITY POLE) EXISTING UTILITY LINE MECO #30 LOCATED ACROSS THE STREET EXISTING UTILITY LINE, EXISTING GUY WIRE EXISTING GUY WIRE JX PROPOSED (1) 1/2" COAX IN 2" CHECKED BY: � ;I CONDUIT FROM RRH TO ANTENNA PROPOSED RGS CONDUIT TO METER �jAPPROVED BY:PROPOSED FIBER IN �r DPH M o 2" U-GUARD PROPOSED FIBER DEMARC BY ~� -H FIBER PROVIDER O 15' AGL SUBMITTALS M o PROPOSED FIBER REV. DATE DESUPTIN BY I `�� m PROPOSED AC/DC CONVERTER (FRONTHAUL do BACKHAUL) PROPOSED RGS CONDUIT PROPOSED LESSEE i (1) AWS RRH _ I EXISTING 3"o x 3'-6' PIPE PROPOSED SAR-0 1 PROPOSED LESSEE 60A FUSED r DISCONNECT do SURGE ARRESTOR10 07/23/20 qLEAM COW A I r PROPOSED LESSEE METER ®pl a srrE NAME. RTH N0 w EXISTING SIGNS , ANDOVER 2 (TO BE RELOCATED ~ ^`_1` AS NEEDED 5' TO 8'-6" (AGL) f T �! ,. SC 16 MA IN ACCORDANCE WITH � ' m UTILITY COMPANY SITE ADDRESS: J REQUIREMENTS E r� 250-336 S. BRADFORD ST. NORTH ANDOVER, MA 01845 v EXISTING UTILITY a POLE MECO #31Zr f �. GROUND LEVEL ! A. r ,4* ,-• SHEET TTiEE ELEV. 0'-O"± (AGL) 1 — I ��L1=11r c u, 3 �7a 155'-O"f (AMSL) II— j1 ELEVATION & PHOTO PROPOSED GROUND ROD SHEET NUMBER 1 GRAPHIC SCALE ELEVATION 0 1'-4" 2'-8' 5'-4' 8'-0" L 2 22x34 SCALE: 3/8"=1'—O" L-2 EXISTING PHOTO DETAIL 2 11x17 SCALE: 3/16"=1'-0" SCALE: N.T.S L-2 LEASE EXHIBIT ZLOIE; 4p THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND AN ANALYSIS OF THE CAPACITY OF THE EXISTING IS INTENDED TO PROVIDE GENERAL INFORMATION STRUCTURE TO SUPPORT THE PROPOSED LOADING 9 EXISTING OVERHEAD REGARDING THE LOCATION AND SIZE OF THE HAS NOT BEEN COMPLETED BY HUDSON DESIGN WIRES BELOW PROPOSED WIRELESS COMMUNICATION FACILITY. THE GROUP, LLC. DRAWINGS ARE SUBJECT TO CHANGE , x SITE LAYOUT WILL BE FINALIZED UPON COMPLETION PENDING OUTCOME OF A STRUCTURAL ANALYSIS. �j� OF SITE SURVEY AND FACILITY DESIGN. PROPOSED LESSEE W ae rP� (1) AWS RRH / EXISTING OVERHEAD V♦ WIRES BELOW Q W PROPOSED LESSEE (1) l\� EXISTING OVERHEAD Hudson D ANTENNA 15'0x24.2"H Np WIRES BELOW Design Group= EXISTING UTILITY POLE 16000SGOODSIRE Er BUILDING 3090 TEL:(978)557-5553 MECO #31 N.ANDO`/ERN MA018e5E336-55865 FAX:1978) Fb\y0 14 15.1"0 * � �� 53' ✓' l? Lj r z RRH DETAIL PLAN 4 5 GRAPHIC SOLE 3 FEET 22x34 SCALE: 1"=1'-0` L-3 + 11x17 SCALE: 1/2 6 + a E ! PROPOSED ANTENNA l l `4- PROPOSED LESSEE1 ( ) CHECKED BY: JX iv i ANTENNA 15.1"0 X 24.2"H p Nr "0 SECONDARY APPROVED BY: DPH N FIBER SUBMITTALS FIBER FRONTHAUL GRD. & BACKHAUL uj REV' DATE DESCIFIION sr 3 a y SAR-0 go � s > f 0 J o 04 1 0 P7/D/2011LUSE D088&flu .6 li i qt N N u PROPOSED CUSTOMJERTER srtE NAMeANTENNA WITHOUT GPS � r MOUNT NORTH ANDOVER AC/DC CONVSC 16 MAZ SITE ADDRESS: 60A SERVICEO250-336 S. BRADFORD ST. 7/8"-14 THREADED EQUIPMENT NORTH ANDOVER. MA 01845 STUD FOR ANTENNA I I EXISTING UTILITY POLE MOUNTINGMECO X31FLAT WASHER SHEET mLE LOCK WASHER RADIO UNITEQUIPMENT DETAILS SMALL CELL CANTENNA DIMENSIONS: 37"Hx11'1Wx6"DDIMENSIONS: 15.1"0x24.2" 7/8"-9 HEX NUT WEIGHT: 55 LBS WEIGHT: 22 LBSMETERSOCKET SHEET NUMBER ANTENNA MOUNTING �_ ANTENNA DETAIL 1 RADIO DETAIL 2 DETAIL 3 GENERAL WIRING DIAGRAM____l l `{+ SCALE: N.T.S L-3 SCALE: N.T.S L-3 SCALE: N.T.S L-3 SCALE: N.T.S L-3 F- 700=850 DALE ST NORTH ANDOVER MA01845 X1 N. ANDOVER MA SC17 W W Q � J Hudson Design Groupuc±<tD 1600 OSGOOD STREET BNLOWG 23 NORTH,SURE 3090 TEL)978)557-5553 N.ANDOVER,MA 01845 FAX:)978)336-5586 V C` C ANIIEL P. KGs s �,hAl'1 cI --.-• fO FFGIS i'S �` '• CHECKED BY: JX €, ..•_• ._ ? APPROVED BY: DPH "• t SUBMITTALS � •. �� REV. DATE DESOWEN ev 1. D 07/21/15 RSR UEM MW I JV ... SITE NAME: N. ANDOVER MA SC17 SITE ADDRESS: 700-850 DALE ST N. ANDOVER MA, 01845 •• SHEET TTI E KEY PLAN 14'S3S3'W ?� Z SHEET NUMBER N KEY PLAN 1 _ SCALE: N.T.S L-1 APPROXIMATE LAT: N47 41' 27.10" ` COORDINATES: LONG: W71' 04' 14.70" NOTES 1 FA-RF_ EXHIBIT = 1. AN ANALYSIS OF THE CAPACITY OF THE EXISTING THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND m STRUCTURE TO SUPPORT THE PROPOSED LOADING IS INTENDED TO PROVIDE GENERAL INFORMATION HAS NOT BEEN COMPLETED BY HUDSON DESIGN REGARDING THE LOCATION AND SIZE OF THE GROUP, LLC. DRAWINGS ARE SUBJECT TO CHANGE PROPOSED WIRELESS COMMUNICATION FACILITY. THE PENDING OUTCOME OF A STRUCTURAL ANALYSIS. SITE LAYOUT WILL BE FINALIZED UPON COMPLETION W OF SITE SURVEY AND FACILITY DESIGN. W 2. SHOP DRAWINGS OF FINAL EXTENSION AND/OR ANTENNA MOUNT TO BE PROVIDED TO ENGINEER OF a RECORD PRIOR TO CONSTRUCTION. APPROXIMATE LAT: N47 41' 27.10" W COORDINATES: LONG: W71' 04' 14.70" J TOP OF PROPOSED ANTENNA Hudson ELEV. = 26'-6-:k AGL Design Group= 186'-6"f (AMSL) OF PROPOSED ANTENNA PROPOSED LESSEE (1) / 16W OSGOOD STREET 25'-6 t(AGLANTENNA 15.1'0 X 24.2'H r y'' BUILDING M NORTH,SURE 3090 TEC 19781557-5553 ELEV. _ rT. 165, 6"f (AMSC) r O�..• • a .Ff (• - N.ANDOVER,MA 01845 FAX:197813365586 TOP OFEXISTING UTILITY POLE ELEV. = 24' (AGL) r$k ✓ 184'-0"t (AMSL) g ^ ' �• '�' 'i PROPOSED POWER FROM , POLE #4726 E i � I EXISTING GUY WIRE 4 PROPOSED WEATHERHEAD I +' 1, ,., EXISTING GUY WIRE j i PROPOSED (1) 1/2" COAX S I ; PROPOSED FIBER FROM IN 2" CONDUIT FROM RRH EXISTING GUY WIRE d " QF �,POLE #4726 TO ANTENNA �S I I = �2 ax .}. �. 1t'.I ""-4. •{_� T r"r '.- `�� L1�\SEL I PROPOSED FIBER IN 2" PROPOSED RGS CONDUIT TO I ' CONDUIT Y METER III 1 EXISTING UTILITY POLE r..', try f ' s•' `+• o. J7LO PROPOSED FIBER DEMARC BY I MECO #4726-5S FIBER PROVIDER O 15' AGL i ` F P �O n. F• �O /ST E m PROPOSED FIBER o PROPOSED AC/DC CONVERTER (FIRONTHAUL do BACKHAUL) ;, a fO I CHECKED BY: JX N C4 PROPOSED RGS CONDUIT I EXISTING UTILITY POLE MECO #4726-5S ' APPROVED BY: DPH N j PROPOSED LESSEE PROPOSED LESSEE 60A FUSED (1) AWS RRH SUBMITTALS DISCONNECT do SURGE ARRESTOR I 1 4, REV. DATE I Br PROPOSED LESSEE METERPROPOSED O SAR-0 h � iL F61-711711 FOR lEIISE DHIF jv SITE NAME: N. ANDOVER MA 5' TO 8'-6" (AGL) - SC 1 7 IN ACCORDANCE WITH UTILITY COMPANY REQUIREMENTS 41' SITE ADDRESS: o O 700-850 DALE ST N. ANDOVER MA, 01845 GROUND LEVEL ELEV. = 0'-0"t (AGL) I I—__ SHEET TTT1E 160'-O"± (AMSL) 1—�I I-1 (—�I _I I CL I =1 I—I 1-1 I I - ELEVATION & PHOTO PROPOSED GROUND ROD r.; ` SHEET NUMBER GRAPHIC SCALE ^ ELEVATION 0 1'-4" 2'-6" 5'-4" 8'-0" EXISTING PHOTO DETAIL 2 2 22x34 SCALE: 3/8"=1'-0" SCALE: N.T.S L-2 11x17 SCALE: 3/16"=1'-0" LEASE EXHIBIT NOT; THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND 1. AN ANALYSIS OF THE CAPACITY OF THE EXISTING m IS INTENDED TO PROVIDE GENERAL INFORMATION STRUCTURE TO SUPPORT THE PROPOSED LOADING REGARDING THE LOCATION AND SIZE OF THE HAS NOT BEEN COMPLETED BY HUDSON DESIGN PROPOSED WIRELESS COMMUNICATION FACILITY. THE GROUP, LLC. DRAWINGS ARE SUBJECT TO CHANGE x SITE LAYOUT WILL BE FINALIZED UPON COMPLETION PENDING OUTCOME OF A STRUCTURAL ANALYSIS. W OF SITE SURVEY AND FACILITY DESIGN. PROPOSED LESSEE (1) 2. SHOP DRAWINGS OF FINAL EXTENSION AND/OR EXISTING UTILITY POLE ANTENNA 15.1'0 X 24.2H W ANTENNA MOUNT TO BE PROVIDED TO ENGINEER OF (n RECORD PRIOR TO CONSTRUCTION. EDGE OF PAVEMENT Q W EXISTING OVERHEAD I y J WIRES BELOW �i PROPOSED LESSEE Hudson (1) AWS RRH DesignGroupuc oN 1600 OSGOOD STREET BUILDING 20 NORTH.SURE 3090 TEL(978)557-5553 N.ANDOVER,MA 01845 FAX:(978)3365586 i DALE ST �. . ��1 T 151'0 ;' /vORy GRAPHIC SCALE RRH DETAIL PLAN tl 4 0 .5 1 2 3 FEET SCALE: MNORTH`'}�` 11 x 17 SCA E: 1/21_10-0" L-3 P\ N v Pit S`s/In C1ANIEL P. r ,rn 1 PROPOSED ANTENNA V c).4 )7 0 �v CHECKED BY: JX' N 1 N PROPOSED N SECONDARY APPROVED BY: DPH LESSEE (1) FIBER t 15•�xx224.2'H SUBMITTALS I FIBER FRONTHAUL GRD. & BACKHAUL KV' DATE Tf C>I �,�'•`� 3 J i~l SAR-0 p UN r• > f - IJ { " COMMSCOPE o a 0 07/21/15 raR U!A%E(M ry rr w ,w MC-MNT-TOP a N i MOUNTING KIT SITE NAME: ANTENNA WITHOUT GPS I ;L j N. ANDOVER MA AC/DC CONVERTER SC 1 7 z SITE ADDRESS: Z1_ 700-850 DALE ST EQUIPMENT SERVICE N. ANDOVER MA, 01845 7/8'-14 THREADED STUD FOR ANTENNA > _ MOUNTING g EXISTING UTILITY POLE } FLAT WASHER nTtE MECO #4726-5S N LOCK WASHER SMALL CELL CANTENNA RADIO UNIT EQUIPMENT DETAILS DIMENSIONS: 15.1"0x24.2" 7/8--9 HEX NUT DIMENSIONS: 37'Hx11'Wx6"D WEIGHT: 22 LBS WEIGHT: 55 LBS METER SOCKET SHEET NUMBER ANTENNA MOUNTING = SCALE: SCALE: NTENNA DETAIL L 13 RADIO DETAIL L23 DETAI Ts L33 GENERAL WIRING DIAGRAM L! \ L-3 H 700=850 DALE ST NORTH MA 01845 ANDOVER X1 N. ANDOVER MA SC17 W W N Q W J Hudson D Design Group= 1600 OSGOOD STREET +t BUILDING 20 NORTH,SURE 3090 TEL:[978I 557-5553 ' - N.ANDOVER.MA 01845 FAX:(978(3365596 ,. to him Sir �. C1AVEL R G 00 o rl\f • da.4J7zJ 0 r �•�• � !`r, rev • r CHECKED BY: JX ,,,-° �" _ .-•.• • *�- APPROVED BY: DPH SUBMITTALS REV. DATE DBOUTI0N BY 0 07/21/15 FOR VA%E7D98R I JV SITE NAME: N. ANDOVER MA ' SC 17 SITE ADDRESS: 700-850 DALE ST N. ANDOVER MA, 01845 • B t •• SHEET TITTLE 1KEY PLAN � ZZ SHEET NUMBER N KEY PLAN 1 _ SCALE: N.T.S L-1 APPROXIMATE LAT: N42' 41' 27.10' COORDINATES: LONG: W71' 04' 14.70' NOTES; LEASE EXHIRIT = 1. AN ANALYSIS OF THE CAPACITY OF THE EXISTING THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND m STRUCTURE TO SUPPORT THE PROPOSED LOADING IS INTENDED TO PROVIDE GENERAL INFORMATION HAS NOT BEEN COMPLETED BY HUDSON DESIGN REGARDING THE LOCATION AND SIZE OF THE X GROUP, LLC. DRAWINGS ARE SUBJECT TO CHANGE PROPOSED WIRELESS COMMUNICATION FACILITY. THE PENDING OUTCOME OF A STRUCTURAL ANALYSIS. SITE LAYOUT WILL BE FINALIZED UPON COMPLETION W OF SITE SURVEY AND FACILITY DESIGN. W 2. SHOP DRAWINGS OF FINAL EXTENSION AND/OR ANTENNA MOUNT TO BE PROVIDED TO ENGINEER OF Q RECORD PRIOR TO CONSTRUCTION. APPROXIMATE LAT: N47 41' 27.10' W COORDINATES: LONG: W71' 04' 14.70' J TOP OF PROPOSED ANTENNA HtJdSOI1 ELEV. = 26--6-* AGL Design Groupuc D 186'-6't (AMSL) OsPROPOSED ANTENNAPROPOSED LESSEE (1) ft 4 „ 16CO OSGOOD STREET 25'-6" BUILDING 20 SUITE 30 TEL 1978)557-5553 15.1'0 X 24.2"H N.ANDOVFR,MA01845 FAX:1978133b5586185'-6"f (AMSL) TOP OF EXISTING UTILITY POLE ;, ELEV. = 24'-0"t (AGL) 184'-O"t (AMSL) y PROPOSED POWER FROM i o POLE 4726 S E EXISTING GUY WIRE " EXISTING PROPOSED WEATHERHEAD - I � 4va � ,,�, ,! ' WIRE 5 ri i PROPOSED (1) 1/2" COAX t ' I PROPOSED_FIBER FROM IN 2" CONDUIT FROM RRH 0 , I ' TO ANTENNA T EXISTING GUY WIRE - 1 POLE X4726 I � { s CSA\IEL PROPOSED RGS CONDUIT TO j PROPOSED FIBER IN 2' o ra- 1 METER I I I CONDUIT _ - � 'MYt- I "`' I .. ' { EXISTING UTILITY POLE 'O.¢J7LU PROPOSED FIBER DEMBY i MECO #4726-55 ��I:,TE� FIBER PROVIDER O 15'' A AGL cO m PROPOSED FIBER a, io iI PROPOSED AC/DC CONVERTER I (FRONTHAUL & BACKHAUL) a fO I CHECKED BY: JX .n EXISTING UTILITY POLE a of PROPOSED RGS CONDUIT MECO #4726-5S � APPROVED BY: DPH I c j PROPOSED LESSEE 1 (1) AWS RRHas SUBMITTALS PROPOSED LESSEE 60A FUSED eE DISCONNECT & SURGE ARRESTOR I I -��- aEv. uve DEsaawlaH rn PROPOSED LESSEE METER PROPOSED O SAR-0 0 07/21/15 FOR IEt%DWBR JV ' SITE NAME: N. ANDOVER MA 5' TO 8'-6" (AGL) : !�� - � SC 1 7 IN ACCORDANCE WITH UTILITY COMPANY REQUIREMENTS it $ti SITE ADDRESS: 700-850 DALE ST N. ANDOVER MA, 01845 14 GROUND LEVEL ' ELEV. = 0'-0"f (AGL) t SHEET 160'-O"± (AMSL) 1-1 I I I I—�I{_�i CI I—I (—I I—I I i x _ H TM.F d I 1-I i-1 I I� 11=1!1-I 11-I f =f I!_I 11=1I 11-1i I -� ELEVATION & PHOTO !1- a PROPOSED �o GROUND ROD SHEET NUMBER GRAPHIC SCALE L ^ ELEVATION 1 0 1'-a' 2'-e' S'-a' s'-o' EXISTING PHOTO DETAIL / L , LJ 22x34 SCALE: 3/8"=1'-0" L-2 SCALE: N.T.S L-2 11x17 SCALE: 3/16"=1'-0" LEASE EXHIBIT NOTES; THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND 1. AN ANALYSIS OF THE CAPACITY OF THE EXISTING m IS INTENDED TO PROVIDE GENERAL INFORMATION STRUCTURE TO SUPPORT THE PROPOSED LOADING REGARDING THE LOCATION AND SIZE OF THE HAS NOT BEEN COMPLETED BY HUDSON DESIGN PROPOSED WIRELESS COMMUNICATION FACILITY. THE GROUP. LLC. DRAWINGS ARE SUBJECT TO CHANGE x SITE LAYOUT WILL BE FINALIZED UPON COMPLETION PENDING OUTCOME OF A STRUCTURAL ANALYSIS. W OF SITE SURVEY AND FACILITY DESIGN. PROPOSED LESSEE (1) 2. SHOP DRAWINGS OF FINAL EXTENSION AND/OR EXISTING UTILITY POLE ANTENNA 15.1'0 X 24.2'H W ANTENNA MOUNT TO BE PROVIDED TO ENGINEER OF RECORD PRIOR TO CONSTRUCTION. EDGE OF PAVEMENT Q J EXISTING OVERHEAD = Hudson WIRES BELOW i K PROPOSED LESSEE Design Groupuc (1) AWS RRH 1600 OSGOOD STREET SULDING 20 NORTH,SURE 3090 TEL 1978)557-5553 N.ANDOVER.MA 01845 FAX(9781336-&W DALE ST rJ 1 s 15 1"0 v � NOR/Y GRAPHIC SCALE RRH DETAIL PLAN 4 0 .5 1 2 3 FEET i A1A01v }� 22x34 SCALE: 1"=1'-0" L-3 �. /u CT/ Cr t' i NORTH 11 x 17 SCALE: 114"=1'-0" SSS A0,11 E L G. PROPOSED ANTENNA--,,,,,,, rI� !O.4 7L0 v1 CHECKED BY: JX C-4 N N SECONDARY PROPOSEDAPPROVED BY: LESSEE DPH FIBER 1 ? 15.1�'Oxx224.2"H SUBMITTALS FIBER FRONTHAUL GRD. £, ( & BACKHAUL � DATE OMCFAnM Be 3 & r 4 SAR-0 0 r U V) ' O COMMSCOPE o as 0 07/21/15 MR LEA%MW w ar or MC-MNT-TOP N N y may¢ MOUNTING KR Srre NAME: ANTENNA WITHOUT GPS i N. ANDOVER MA ! AC/DC CONVJERTER SC 1 7 +� z SRE ADDRESS: v Z to 60A SERVICEo ' 700-850 DALE ST 7/8"-14 THREADED EQUIPMENT N. ANDOVER MA 01845 STUD FOR ANTENNA MOUNTINGFLAT WASHER EXISTING UTILITY POLE SHM TRLE LOCK WASHERMECO #4726-5SSMALL CELL CANTENNA RADIO UNIT EQUIPMENT DETAILS DIMENSIONS: 15.1"0x24.2' 7 8 -9 HEX NUT DIMENSIONS: 37"Hx11Wx6"DWEIGHT: 22 LBS WEIGHT55 LBS METER SOCK SHEET NUMBER ANTENNA DETAIL / 1 RADIO DETAIL 2 DETAIL ANTENNA MOUNTING 3 GENERAL WIRING DIAGRAM �� L-3 SCALE: N.T.S L-3 SCALE: N.T.S L-3 SCALE: N.T.S L-3 SCALE: N.T.S L-3 •to • . m A , • . A ' : .. • Hudson Design Groupuc160D OSCOOD STREET BUILDING 20 NORTH,SUITE 3D90 Ta:1978)557-5553 s , _ ' y 1. 4 f�75* +r . c 9 M. '- ,' :�: � ' � ,�, �• d nib � � � � � �, " e PROPOSED LESSEE ' ANTENNA MOUNTED TO EXISTING UTILITY POLE ,. a ETING OLE a r, XIS G TILIIY P .i, c ' EXISTING UTILITY POLE NG'5222 PROlOSEDeLESSE4 MOUNTEDTOEXISTING UTILITY POLE a x SITE NAME. • r! b RI } ��' s ` '= •-'7- N ANDOVER "rMA At SffE ADDRESS: Z" NORTH ANDOVER, MA 01845 Ir .. 3r - a s b , •v tw ©,2015 GOOGLE APPROXIMATE LAT. N42' 41' 41.8'a COORDINATES: LONG: W71' 04' 02.3" NOTES LEASE EXHIBIT = 1. AN ANALYSIS OF THE CAPACITY OF THE EXISTING THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND m STRUCTURE TO SUPPORT THE PROPOSED LOADING IS INTENDED TO PROVIDE GENERAL INFORMATION HAS NOT BEEN COMPLETED BY.HUDSON DESIGN REGARDING THE LOCATION AND SIZE OF THE GROUP, LLC. DRAWINGS ARE SUBJECT TO CHANGE PROPOSED WIRELESS COMMUNICATION FACILITY. THE W PENDING OUTCOME OF A STRUCTURAL ANALYSIS. SITE LAYOUT WILL BE FINALIZED UPON COMPLETION TOP OF PROPOSED ANTENNA OF SITE SURVEY AND FACILITY DESIGN. W ELEY.= 41 '- t (AGL) ANTENNA MOUNT TO BE PROVIDED SHOP DRAWINGS OF FINAL EDTOSIENGINEEON ROOF Q 205'-8"t (AMSC) RECORD PRIOR TO CONSTRUCTION. ��F_PROPOSED_ANTENNA _ PROPOSED LESSEE (1) [APPROXIMATE LAT: N47 41' 41.8" JEl EV.= 40'-6"t (AGL) ANTENNA 15.1"0 X 24.2"H ORDINATES: LONG: W71' 04' 02.3" 204'-6"t (AMSL) �� Hudson H PROPOSED 5'-0"H FIBERGLASS - �, Design Groupuc � EXTENSION I EXISTING PRIMARY POWER 1600 OSGOOD STREET BUILDING 20 NORTH,SURE 3090 TEL:19781557-5553 ±*D '4 N.ANDOVER,MA01845 FAX:197813365586 0 �- E E E E-� q5 TOP OF EXISTING UTILITY POLE ELEV, 34'-0"t (AGL) �\ �POWER EXISTING PRIMARY 198'-O"t (AMSL) EXISTING UTILITY POLE ` NG 5222 EXISTING SECONDARY EXISTING SECONDARY PROPOSED WEATHERHEAD POWER POWER GFS N OF *, S(, E E E EXISTING CABLE O ANIEL P_ EXISTING CABLE � EXIST `` - EXISTING FIBER F < H NGEXISTING 2 UTILITY POLE I �•i��OPdA;i TVA) PROPOSED RGS CONDUIT TO METER PROPOSED (1) 1/2" COAX CHECKED BY: JX IN 2" CONDUIT FROM RRH z TO ANTENNA EXISTING U-CONDUIT i APPROVED BY: DPH PROPOSED FIBER IN 2" U—GUARD PROPOSED FIBER DEMARC BY .'` SUBMITTALS FIBER PROVIDER O 15' AGL ` PROPOSED AC/DC CONVERTER PROPOSED FIBER Y 1 > � a" "�(y'� I� � DATE � N BY (FRONTHAUL do BACKHAUL)PROPOSED Y _ PROPOSED RGS CONDUIT (1) AWS RRSEE �. 4 PROPOSED LESSEE 60A FUSED PROPOSED SAR-0 DISCONNECT & SURGE ARRESTOR PROPOSED LESSEE METER o 07/20/15 VA%INHIBIT I urs a SITE NAME: EXISTING CABINET N ANDOVER SCS 8 MA 5' TO 8'-8" (AGL) g ~'.* EXISTING CABINET SITE ADDRESS: IN ACCORDANCE WITH �� `" NORTH 1ARUSSETT LN. NDOVER, MA 01845 UTILITY COMPANY REQUIREMENTS v - GROUND LEVEL SHEET T� ELEV. = 0'-0"t (AGL) I — rPOSED I- 164'-O" (AMSL) ELEVATION & PHOTO IPRUND ROD SHEET NUMBER ELEVATION 1 GRAPHIC 5CALE 22x34 SCALE: 3/8"=1'-D" L-2 4 1'--9' 2'-s'_ s'-a" 8.GRAPHIC EXISTING PHOTO DETAIL 2 L-2 11x17 SCALE: 3/16"-1'-0" SCALE: N.T.S L-2 LEASE EXHIBIT NOTES: F.. THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND 1. AN ANALYSIS OF THE CAPACITY OF THE EXISTING m IS INTENDED TO PROVIDE GENERAL INFORMATION STRUCTURE TO SUPPORT THE PROPOSED LOADING REGARDING THE LOCATION AND SIZE OF THE HAS NOT BEEN COMPLETED BY HUDSON DESIGN PROPOSED WIRELESS COMMUNICATION FACILITY. THE GROUP, LLC. DRAWINGS ARE SUBJECT TO CHANGE x SITE LAYOUT WILL BE FINALIZED UPON COMPLETION PENDING OUTCOME OF A STRUCTURAL ANALYSIS. PROPOSED 5'-0"H a W OF SITE SURVEY AND FACILITY DESIGN. FIBERGLASS EXTENSION W 2. SHOP DRAWINGS OF FINAL EXTENSION AND/OR ANTENNA MOUNT TO BE PROVIDED TO ENGINEER OF RECORD PRIOR TO CONSTRUCTION. PROPOSED LESSEE (1) W Q ANTENNA 15"0x24.2"H w PR POSED LESSEE : � J Hudson 1 AWS RRH 7 ```�� ' � D OH ON ON_ON Design Groupuc 1600 OSGOOD STREET EXISTING OVERHEAD BUILDING 20 NORTH,SURE 3090 TEC 19781557-5553 WIRES BELOW N.ANDOVER,MA 01845 FAX:19781336-5586 6 DALE ST. GRAPHIC SCALE Z?fj'�Z RRH DET: 1"PLAN L43 a 5 1 2 3 FEET 11x17 SCALE: 1/2"=1'-0" OF PROPOSED ANTENNA i k i II.�.4. 7�C.. /STERE—�' c;- �n" �I i CHECKED BY: JX 10 N + PROPOSED 0 SECONDARY N 1 LESSEE (1) =N APPROVED BY: DPH, ANTENNA FIBER 15.1"0x24.2H SUBMITTALS FIBER FRONTHAUL GRD. & BACKHAUL w REv. DATE 0MORFIaw By w 3 ' SAR-0 p co '1 O �J COMMSCOPE o a o m/m/1s L t:wert MR d MC—MNT—TOP N 7 j`-'t O MOUNTING KIT (' SITE NAME: ANTENNA WITHOUT GPS N ANDOVER SC18 f AC/DC CONVJERTER MA ! !� •" SITE ADDRESS: Z 60A SERVICEo 1 RUSSETT LN. 7/8"-14 THREADED 61 PROPOSED EQUIPMENT � NORTH ANDOVER, MA 01845 STUD FOR ANTENNA FIBERGLASS POLE—TOP%q MOUNTING EXTENSION FLAT WASHER SHEET TITLE LOCK WASHER RADIO UNff SMALL CELL CANTENNA EQUIPMENT DETAILS DIMENSIONS: 37"Hx11"Wx6"D DIMENSIONS: 15.1'0x24.2" 7/8"-9 HEX NUT WEIGHT: 55 LBS WEIGHT: 22 LBS METERSK SHEET NUMBER ANTENNA MOUNTING ANTENNA DETAIL 1 RADIO DETAIL2 DETAIL 3 GENERAL WIRING DIAGRAM 5 L-3 SCALE: N.T.S L-3 SCALE: N.T.S L-3 SCALE: N.T.S L-3 SCALE: N.T.S L-3 r, a, * M � Hudson D 1 � R� • q Design Groupuz lot x p 4 } .G • ONORTH,SUrr 3090 TEL: . _ - '. � N ANDOVER,MA01845 FAX:[9781336-5586 01 All rn tz c a y r• } e ti � TM h x r W *. PROPOSED LESSEE , „ ' ANTENNA MOUNTED TO * «?N r EXISTING UTILITY POLE ,�. EXISTING UTILIPOLE EX S TY a 1 + EXISTING UTILITY POLE NG '5222 . .- ,, a ...•,• =-w '' . OPO SED eLESSEERRHa �mO� + MOUNTED'#TOJEXISTING f �� lliTY POLE , x71 - -- , 4f MA - 'w l NORTH ANDOVER, • 1845 n k r Am 4 „ s 015GOOGLE a NOTES LEASE EXHIBIT 1. AN ANALYSIS OF THE CAPACITY OF THE EXISTING THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND m STRUCTURE TO SUPPORT THE PROPOSED LOADING IS INTENDED TO PROVIDE GENERAL INFORMATION HAS NOT BEEN COMPLETED BY HUDSON DESIGN REGARDING THE LOCATION AND SIZE OF THE X GROUP, LLC. DRAWINGS ARE SUBJECT TO CHANGE PROPOSED WIRELESS COMMUNICATION FACILITY. THE PENDING OUTCOME OF A STRUCTURAL ANALYSIS. SITE LAYOUT WILL BE FINALIZED UPON COMPLETION W TOP OF PROPOSED ANTENNA OF SITE SURVEY AND FACIL17Y DESIGN. OF FINAL ELEV= f AAL ANANSIR W 205'-6"t (AMSC) NTENMOUNT TO BE PROVIDED TO ENGINEER OF Q RECORD PRIOR TO CONSTRUCTION. QF PROPOSED ANTENNA _ PROPOSED LESSEE (1) APPROXIMATE LAT: N42' 41' 41.8" W ELEV.= 40'-6"t (AGL) COORDINATES: LONG: W71' 04' 02.3' J 204'-6"t (AMSC) ANTENNA 15.1"A X 24.2"H IN PROPOSED 5'-O"H FIBERGLASS `�- DeDesign IK�SO11 � EXTENSIONCID H I EXISTING PRIMARY POWER 1600 OSGOOD STREET BUILDING 20 NORTH,SURE 3090 TEL:19781557-5553 �--- E E E E N.ANDOVER,MA 01865 FAX:19781336-5586 o TOP OF EXISTING UTILITY POLE ELEV.= 34'-0"t (AGC) POWER G PRIMARY 198'-0"t (AMSL) EXISTING UTILITY POLE NG 5222 POWER EXISTING SECONDARY _ EXISTING SECONDARY OF f PROPOSED WEATHERHEAD POWER ` �, ,5� `, c E E E - - _ [ ANIIEL P. iG EXISTING CABLE O S EXIST BER �I L EXISTING CABLE 11ff l� :H - EXISTING FIBER co -i �Or.r STE `v, EXISTING UTILITY POLE rN/L PROPOSED RGS CONDUIT TO METER PROPOSED (1) 1/2" COAX IN 2' CONDUIT FROM RRH CHECKED BY: JX TO ANTENNA EXISTING U-CONDUIT +. ' PROPOSED FIBER IN APPROVED BY: DPH . s> PROPOSED FIBER DEMARC BY 2" U-GUARD FIBER PROVIDER O 15' AGL SUBMITTALS DATE DMC17FO By PROPOSED AC/DC CONVERTER PROPOSED FIBER (FRONTHAUL do BACKHAUL) ' PROPOSED RGS CONDUIT PROPOSED LESSEE (1) AWS RRH PROPOSED LESSEE 60A FUSED PROPOSED SAR-0 DISCONNECT do SURGE ARRESTOR 0 07/20/15 LEASE MIST J.PROPOSED LESSEE METER 0 � W CL SLTE NAME: EXISTING CABINET Q N ANDOVER SC18 pp� MA 5' TO 8'-6" (AGL) O SrTE ADDRESS: IN ACCORDANCE WITH mr,; rs EXISTING CABINET 1 RUSSETT LN. UTILITY REQUIREMENTSY < NORTH ANDOVER, MA 01845 o - - 0GROUND LEVEL SHEET TRIS ELEV. = 0'-0"t (AGL) I— 1=. I 1 164'-0"t (AMSL) I I I (— ELEVATION & PHOTO -II—I�1I ����T �I�11= ;II�IrF PROPOSED GROUND ROD SHEET NUMBER ELEVATION " GRAPHIC SCALE 22x34 SCALE: 3/8"=1'-0" L-2 EXISTING PHOTO DETAIL 2 L-2 11x17 SCALE. 3/16"=1'-0 SCALE: N.T.S L-2 LEASE EXHIBIT NOTES: - THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND 1. AN ANALYSIS OF THE CAPACITY OF THE EXISTING m IS INTENDED TO PROVIDE GENERAL INFORMATION STRUCTURE TO SUPPORT THE PROPOSED LOADING REGARDING THE LOCATION AND SIZE OF THE HAS NOT BEEN COMPLETED BY HUDSON DESIGN PROPOSED WIRELESS COMMUNICATION FACILITY. THE GROUP, LLC. DRAWINGS ARE SUBJECT TO CHANGE X SITE LAYOUT WILL BE FINALIZED UPON COMPLETION PENDING OUTCOME OF A STRUCTURAL ANALYSIS. PROPOSED 5'-0"H a W OF SITE SURVEY AND FACILITY DESIGN. FIBERGLASS EXTENSION W 2. SHOP DRAWINGS OF FINAL EXTENSION AND/OR ANTENNA MOUNT TO BE PROVIDED TO ENGINEER OF RECORD PRIOR TO CONSTRUCTION. PROPOSED LESSEE (1) W Q -- ANTENNA 15"Ox24.2"H SIJ ( PROPOSED LESSEE i �� ,..I Hudson 1 AWS RRH j D I ON ON ON—ON Design GtoUpuc EXISTING OVERHEAD 1600 OSGOOD STREET WIRES BELOW BUILDING 20 NORTH,SUITE 3090 TEL:19781557-5553 N.ANDOVER,MA 01845 FAX:(978)336-5586 Ark 4 d DALE ST. 14'53' 15.1"0 y\ 1 W= GRAPHIC SCALE 11� RRH DETAIL PLAN 4 D 5 1 2 3 FEET I—Z 22x34 SCALE: 1`1= '-0" L-3 11x17 SCALE: 1/2"=1'—O" y,N CiF '1�4S, ANIEL P. 0. IV, 1 a e PROPOSED ANTENNA CIV 11 4, 0 I �n FCGI�T1 acv o CHECKED BY: JX N 1 PROPOSED SECONDARY N LESSEE (1) 1 — N APPROVED BY: DPH ANTENNA 15.1"0x24.2"H FIBER SUBMITTALS FIBER FRONTHAUL GRD. & BACKHAUL w REV. 01 EDMORPTOBy 3 SAR-0 0� .. vIn ! 0 J ' * COMMSCOPE �a o a�/zo/Is LEASE DHBR 4A MC—MNT—TOP c�•i 1"* +" O MOUNTING KIT V' SITE NAME: ANTENNA WITHOUT GPS i N ANDOVER SC18 } AC/DC CONVJERTER MA Z SITE ADDRESS: 60A SERVICE0 1 RUSSETT LN. 7/8"-14 THREADED PROPOSED EQUIPMENTJ NORTH ANDOVER, MA 01845 STUD FOR ANTENNA FIBERGLASS POLE—TOPMOUNTINGEXTENSIONFLAT WASHER SHEET TILE LOCK WASHER RADIO UNIT SMALL CELL CANTENNA EQUIPMENT DETAILS bIMENSIONS: 37"Hx11"Wx8"DDIMENSIONS: 15.1"0x24.2' 7/8"-9 HEX NUT WEIGHT: 55 LBS WEIGHT: 22 LBS METO SHEET NUMBER ANTENNA MOUNTING ANTENNA DETAIL 1 RADIO DETAIL 2 DETAIL GENERAL WIRING DIAGRAM 5 �_3 SCALE: N.T.S L-3 SCALE: N.T.S L-3 SCALE: N.T.S L 3 SCALE: N.T.S L-3 F- 494=498 IPSWICH ROAD, NORTH ANDOVER , MA 01845 x N ANDOVER SC19 MA W cn a Hudson Design Gaoupuc 16000SGOODSTREET ** BUILDING 20 NORTH.SUITE 3090 TEL:(978)557555) N.ANDOVER,MAO 1845 FV:(978)3365586 AL Ll 1 "1 s < w. ° r � �IR�lif III - & • ._: ,,» � .� ��-. � ° CHECKED BY: JX APPROVED BY: DPH •• ! SUBMITTALS DUE DEWW11011 er ff * , *W IT x v I i LE'A8E DHErFSITE NAME CP ? ': u > NAND , OVER SC19 MA SITE ADDRESS: 494-498 IPSWICH RD NORTH ANDOVER, MA 01845 ' r: "' i« ; �:.�'e f ai<"' r, O <. •• SHEET TITLE r w < KEY PLAN =14! ce 5454 W Qy� z KEY PLAN 1 SHEEP NUMBER � N SCALE: N.T.S L-1 I APPROXIMATE LAT: N47 41' 50.1' COORDINATES: LONG: W71. 03' 01.9' LEASE EXHIR r TOP OF PROPOSED ANTENNA AN ANALYSIS OF THE CAPACITY OF THE EXISTING THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND m ELEV.= 44'- t AGL STRUCTURE TO SUPPORT THE PROPOSED LOADING IS INTENDED TO PROVIDE GENERAL INFORMATION HAS NOT BEEN COMPLETED BY HUDSON DESIGN REGARDING THE LOCATION AND SIZE OF THE 196'-0'f (AMSC) GROUP, LLC. DRAWINGS ARE SUBJECT TO CHANGE PROPOSED WIRELESS COMMUNICATION FACILITY. THE Uj QF PROPOSEDNT AENNA _ PROPOSED LESSEE (1) PENDING OUTCOME OF A STRUCTURAL ANALYSIS. SITE LAYOUT WILL BE FINALIZED UPON COMPLETION W ELEV.= 43'-0"t (AGL) ANTENNA 15.1'0 X 24.2'H OF SITE SURVEY AND FACILITY DESIGN. W 195'-D't (AMSL) PROPOSED CUSTOM MOUNT Q it PROPOSED 3'-0'H FIBERGLASS APPROXIMATE LAT: N42' 41' 50.1" W t-IkTOP OF EXISTING UTILITY POLE `j EXTENSION COORDINATES: LONG: W71' 03' 01.9" LU ELEV.= 38'-6"t (AGL) v 190'-6"f (AMSL) Hudson p ? E E E Design Group= PROPOSED WEATHERHEAD -E E E E E � _ ,. qa _ 160005GOOD STREET #F T BUILDING 20 NORTH,SUITE 3090 TEL:1978)5575553 7 ' N.ANDOVER,MA 01845 FAX:(978)3365586 t ... ........ EXISTING PRIMARY POWER - EXISTING UTILITY POLE i NET&T Co #2/231 S _ #1611 EXIST) ,PRIMARY POWER EXISTING UTILITY POLE {T. EXISTING TELCO # NET&T Co 2/231 #1611 4j `o EXISTING FIBER 1 I C I —H } . I 00 PROPOSED (1) 1/2" COAX ;� CHECKED BY: JX PROPOSED RGS CONDUIT TO METER IN 2" CONDUIT FROM RRH APPROVED BY: DPH TO ANTENNA v T, PROPOSED FIBER DEMARC BY PROPOSED FIBER IN > TI~ `'' FIBER PROVIDER O 15' AGL 2" U-GUARD SUBMITTALS t r r� REV. DATE DESCRIPTION er PROPOSED AC/DC CONVERTER PROPOSED FIBER (FRONTHAUL & BACKHAUL) PROPOSED RGS CONDUIT PROPOSED LESSEE I (1) AWS RRH - - PROPOSED LESSEE 60A FUSED PROPOSED SAR-0 DISCONNECT & SURGE ARRESTOR PROPOSED LESSEE METER ° 0 07/22/15 1 VkSE CHBIT ct' SrTE NAME: CL •_ N ANDOVER SC 19 W yx• -0 MA o 5' TO 8'-6" (AGL) om SrtE ADDRESS: IN ACCORDANCE WITH s - - 494-498 IPSWICH RD UTILITY COMPANY NORTH ANDOVER, MA 01845 REQUIREMENTS a c~ 0 EGROUND LEVEL "y. SHEET TrfLE LEV. = 0' (AGL) I 152-0"t (AMSL) _ l I�l I 'ps - - = t ELEVATION & PHOTO PROPOSED GROUND ROD - - - SHEET NUMBER 1 GRAPHIC SCALE ELEVATION 0 1'-4• 2'-8' 5'-4' 8'-0" �_n 22x34 SCALE: 3/8"=1'-0" L-2mould EXISTING PHOTO DETAIL 2 G 11x17 SCALE: 3/16"=1'-0" SCALE: N.T.S L-2 LEASE EXHIBIT N F. THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND AN ANALYSIS OF THE CAPACITY OF THE EXISTING m IS INTENDED TO PROVIDE GENERAL INFORMATION STRUCTURE TO SUPPORT THE PROPOSED LOADING REGARDING THE LOCATION AND SIZE OF THE HAS NOT BEEN COMPLETED BY HUDSON DESIGN PROPOSED WIRELESS COMMUNICATION FACILITY. THE GROUP, LLC. DRAWINGS ARE SUBJECT TO CHANGE x SITE ESLAYOUT WILL BE ITE SURVEY AND FACILITY DESIGN.COMPLETION PENDING OUTCOME OF A STRUCTURAL ANALYSIS. IPSWICH RD LLI W m a EDGE OF PAVEMENTLU PROPOSED 3'—0"H Hudson p FIBERGLASS EXTENSION Design GroupLLc PROPOSED LESSEE (1) AWS RRH PROPOSED LESSEE (1) 1600 OSGOOD STREET ANTENNA 15"0x24.2"H BUILDING 20 NORTH,SUITE 3090 TEL:(978)557-5553 i �- N.ANDOVER,MA 01845 FAX:(978)336-5586 % _ T �` ON � 04 ON � *' 1454' •,� RF. L) p GRAPHIC SCALE Z Z RRH DETAIL PLAN 4 0 .5 1 2 3 FEET ,,* N 22x34 SCALE: 1"=1'—O" L-3 ". PROPOSED LESSEE (1) 11x17 SCALE: 1/2"=1'-0" I ANTENNA 15.1'0 X 24.2"H PROPOSED ANTENNA I aa; CHECKED BY: JX C-4 Llj N SECONDARY APPROVED BY: DPH FIBER SUBMITTALS FIBER FRONTHAUL GRD. & BACKHAUL Uj a�rE DEsc 3 SAR-0 p z )p t PROPOSED CUSTOM > . / MOUNT N J 'I "` \a 0 W/zz/1a WASE EMW CP lu S Ll � I N� t�: s' I �N SITE NAME ANTENNA WITHOUT GPS i N ANDOVER SC19 AC/DC CONVJERTER MA SITE ADDRESS: 60A SERVICEp 494-498 IPSWICH RD EQUIPMENT NORTH ANDOVER, MA 01845 0\ 7/8"-14 THREADED to MOUNTING ANTENNA PROPOSED 3'-0"H FIBERGLASS EXTENSION FLAT WASHER SHEET TnU LOCK WASHER RADIO UNIT SMALL CELL CANTENNAEQUIPMENT DETAILS DIMENSIONS: 37"Hx 11'YVX6"D DIMENSIONS: 15.1"0x24.2" 7/8"-9 HEX NUT WEIGHT: 55 LBS WEIGHT: 22 LBS — METER SOCKET SHEET NUMBER ANTENNA MOUNTING ANTENNA DETAIL / \ RADIO DETAIL 2 DETAIL 3 GENERAL WIRING DIAGRAM L-3 SCALE: N.T.S L-3 SCALE: N.T.S L-3 SCALE: N.T.S L-3 SCALE: N.T.S L-3 H 494=498 IPSWICH ROAD , NORTH ANDOVER , MA01845 N ANDOVER SC19 MA W cn J Hudson Design Groupac 1600 OSGOOD STREET BUILDING YD NORTH,SURE 3090 TEL)978)557-5553 t: N.ANDOVER,MA 01845 FAX:)978)336-5586 4 91111111777 4 's �,. CHECKED BY: JX • k + t APPROVED BY: DPH a'Y rev. WEDExwrraHOf SUBMITTALS 414- �r w S P E It o 07/22/15 UASEoouar OR SrrE NAME, jc D V R �x N AN O E SC19 4 � MA lipK SrrE ADDRESS: 494-498 IPSWICH RD x 1 NORTH ANDOVER. MA 01845 ±n ` �• •• SHEET TITLE KEY PLAN ZJ'v 5454'W Qy��z KEY PLAN 1 SHEET NUMBER � N SCALE: N.T.S L-1 APPROXIMATE LAT: N47 41' 50.1" ` COORDINATES: LONG: W71. 03'.01.9" 1 FACE_ EYwLLaLr TOP OF PROPOSED ANTENNA AN ANALYSIS OF THE CAPACITY OF THE EXISTING THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND m ELEV.= 44-0 t AGL STRUCTURE TO SUPPORT THE PROPOSED LOADING IS INTENDED TO PROVIDE GENERAL INFORMATION HAS NOT BEEN COMPLETED BY HUDSON DESIGN REGARDING THE LOCATION AND SIZE OF THE x 19196'-0't (AMSL) GROUP, LLC. DRAWINGS ARE SUBJECT TO CHANGE PROPOSED WIRELESS COMMUNICATION FACILITY. THE OF PROPOSTENNA _ PROPOSED LESSEE (1) PENDING OUTCOME OF A STRUCTURAL ANALYSIS. SITE LAYOUT WILL BE FINALIZED UPON COMPLETION W ED AN ELEV.= 43'-O't (AGL) ANTENNA 15.1"0 X 24.2'H OF SITE SURVEY AND FACILITY DESIGN. W 195'-0't (AMSL) PROPOSED CUSTOM MOUNT 4i PROPOSED 3'-O"H FIBERGLASS APPROXIMATE LAT: N42' 41' 50.1' W TOP OF EXISTING UTILITY POLE 0 EXTENSION COORDINATES: LONG: W71' 03' 01.9' J ELEV.= 38'-6"t (AGL) D 190'-6"t (AMSC) Hudson E E E Design Groupac E E E PROPOSED WEATHERHEAD 1600 OSGOOD STREET 4 BUILDING20 NORTH,SURE 3090 TEL(978)557-5553 N.ANDOVER,MA 01845 FAX:(978)336-5586 +77.° EXISTING PRIMARY POWER EXISTING UTILITY POLE --�— f NET&T Co #2/231 E S #1611 "K EXISTING PRIMARY POWER I 4 EXISTING UTILITY POLE * ; # NET&T Co 2/231 EXISTING TELCO #1611 I o EXISTING FIBER 00I CHECKED BY: JX PROPOSED (1) 1/2 COAX I '' zw- PROPOSED RGS CONDUIT TO METER IN 2' CONDUIT FROM RRH TO ANTENNAAPPROVED BY: DPH 4, PROPOSED FIBER IN , PROPOSED FIBER DEMARC BY 2' U-GUARD IN `' SUBMITTALS FIBER PROVIDER O 15' AGL #F DATEL>ESCPoPIION ar PROPOSED AC/DC CONVERTER PROPOSED FIBER L (FRONTHAUL & BACKHAUL) PROPOSED RGS CONDUIT L PROPOSED LESSEE (1) AWS RRH PROPOSED LESSEE 60A FUSED PROPOSED LESSEE METER � PROPOSED SAR-O DISCONNECT & SURGE ARRESTOR R o 07/22/15 ILEASE MUST re W SITE NAME d, N ANDOVER SC 19 MA a — "I A —.1 5' TO 8'-6' (AGL) m T SITE ADDRESS: IN ACCORDANCE WITH - - 494 H R UTILITY COMPANY fL NORTH ANDOVER, MA 0 845 REQUIREMENTS ak, r":.r t ;L _ AGROUND LEVEL " +. SHEEP TITLE ELEV. = 0'-07'f (AGL) 11=j1� I jI 152-0"t (AMSC) 'y- ELEVATION & PHOTO 1—�_, I- _I �I III �* c -�.. c ll PROPOSED GROUND ROD SHEET NUMBER ELEVATION 1 GRAPHIC SCALE 0 1'-4" 2'-8' T-4' 8'-0" ��n 22x34 SCALE: 3/8'=1'-O" L-2 EXISTING PHOTO DETAIL �� G 11x17 SCALE: 3/16"=1'-0" SCALE: N.T.S L-2 LEASE EXHIBIT N THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND AN ANALYSIS OF THE CAPACITY OF THE EXISTING m IS INTENDED TO PROVIDE GENERAL INFORMATION STRUCTURE TO SUPPORT THE PROPOSED LOADING REGARDING THE LOCATION AND SIZE OF THE HAS NOT BEEN COMPLETED BY HUDSON DESIGN x PROPOSED WIRELESS COMMUNICATION FACILITY. THE GROUP, LLC. DRAWINGS ARE SUBJECT TO CHANGE SITE LAYOUT WILL BE FINALIZED UPON COMPLETION PENDING OUTCOME OF A STRUCTURAL ANALYSIS. jpS�PICH RD w OF SITE SURVEY AND FACILITY DESIGN. W Q EDGE OF PAVEMENT J PROPOSED 3'-0"H Hudson I, FIBERGLASS EXTENSION Design Groupuc PROPOSED LESSEE (1) AWS RRH PROPOSED LESSEE (1) 1600 OSGOOD STREET ANTENNA 15"0x24.2"H BUILDING 20 NORTH,SUITE 3090 TEL:(978)557-5553 N.ANDOVER.MA 01&5 FAX:(978)336-5586 i i 1 1 I OH OH OH OH ON 0!1 ON ON 1 7 t ' � q Fl { �J 0# ® _ _ 14*54 Of GRAPHIC SCALE 15'1"o - Z z RRH DETAIL PLAN 4 0 .5 1 2 3 FEET J1r 2204 SCALE: 1"=1'-0" L-3 1107 SCALE: 1/2"=1'-0" 1 PROPOSED LESSEE (1) ti 1 ANTENNA 15.1'0 X 24.2"H w � `c s F { PROPOSED ANTENNA f CHECKED BY: JX iv Im SECONDARY — ?N APPROVED BY: DPH N FIBER SUBMITTALS 1 FIBER FRONTHAUL GRD. & BACKHAUL w REV. DATE DL MPMN at 0 3 SAR-0 p cD PROPOSED CUSTOM a r MOUNT v r CN J ` Y i d F. 01/22/15 V"Dim CP l9) I 0=i aw SITE NAME: ANTENNA WITHOUT GPS �I, i N ANDOVER SC19 AC/DC CONVJERTER MA Z SRE ADDRESS: 60A SERVICEo 494-498 IPSWICH RD 7/8"-14 THREADED ) EQUIPMENT NORTH ANDOVER, MA 01845 STUD FOR ANTENNA MOUNTINGPROPOSED 3'-0"H0 FIBERGLASS EXTENSIONFLAT WASHER SHEET TITLE LOCK WASHER RADIO UNITSMALL CELL CANTENNA DIMENSIONS: 37"Hx11"Wx6D EQUIPMENT DETAILS DIMENSIONS: 15.1"0x24.2" 7/8"-9 HEX NUT WEIGHT: 55 LBS WEIGHT: 22 LBS METERS SHEET NUMBER ANTENNA MOUNTING ANTENNA DETAIL 1 RADIO DETAIL z DETAIL 3 GENERAL WIRING DIAGRAM L-3 SCALE: N.T.S L-3 SCALE: N.T.S L-3 SCALE: N.T.S L-3 SCALE: N.T.S L-3 H 1 =99 BANNAN DR . , NORTH ANDOVER , MA 01845 X N ANDOVER SC20 NIA W cn a W Hudson p Design GroupLLc r 1600 OSGOOD STREET BUILDING 20 NORTH,SUITE 3090 TEL:(9M557-5553 N.ANDOVER,MA 01845 FAX:X9781336-5586 ak "�rz•� sf r�" \A f ANIF1 P. /�Gn I lo.4 720 A 2 xa_ S/Oml I ENS. �O CHECKED BY: JX APPROVED BY: DPH SUBMITTALS •• , REV. WE DESfAla,1@, sr .. '• 0 37/23/2015 IFUE DOER a SITE NAME: r N ANDOVER SC20 .` MA SRE ADDRESS: 1-99 BANNAN DR. , NORTH ANDOVER, MA 01845 O � 0 , O E •• SHM7 TITLE KEY PLAN 14!5 '� �0 ZD?� Z SHEET NUMBER N KEY PLAN 1 _ SCALE: N.T.S L-1 APPROXIMATE LAT: N42' 40' 23.68' ` COORDINATES: LONG: W71' 05' 30.92' NOTES: LEASE EXHIRIT 1. AN ANALYSIS OF THE CAPACITY OF THE EXISTING THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND m STRUCTURE TO SUPPORT THE PROPOSED LOADING IS INTENDED TO PROVIDE GENERAL INFORMATION HAS NOT BEEN COMPLETED BY HUDSON DESIGN REGARDING THE LOCATION AND SIZE OF THE GROUP, LLC. DRAWINGS ARE SUBJECT TO CHANGE PROPOSED WIRELESS COMMUNICATION FACILITY. THE PENDING OUTCOME OF A STRUCTURAL ANALYSIS. SITE LAYOUT WILL BE FINALIZED UPON COMPLETION W 2. SHOP DRAWINGS OF FINAL EXTENSION AND/OR OF SITE SURVEY AND FACILITY DESIGN. W ANTENNA MOUNT TO BE PROVIDED TO ENGINEER OF Q RECORD PRIOR TO CONSTRUCTION. APPROXIMATE LAT: N47 40' 23.68" W COORDINATES: LONG: W71' 05' 30.92" J TOP OF PROPOSED ANTENNA Hudson ELEV.= 3 -0 f AGL Design Groupnc 238'-O"t (AMSC) OF ROPOSED NTENNA 160003GOOD STREET PROPOSED LESSEE (1) - - ANTENNA 15.1"p X 24.2"H ELEV.= 36'-D"f (AGL) BUILDING 20 NORTH, SURE 3090 TEL:19781557-5553 237'-0"t (AMSL) -- N.ANDOVER,MA 01845 FAX:197813365586 EXTENSION EXISTING PRIMARY POWER ESED 5'-0'H FIBERGLASS yyy EXISTING SECONDARY POWER EXTENSION rr,�`� � ' EXISTING PRIMARY F R E E POWE F ti TOP OF EXISTING UTILITY POLE ELEV.= 29'-6"f (AGL) EXISTING GUY WIRE EXISTING TELCO 230'-6"t (AMSL) POWER EXISTING SECONDARY OF + SS PROPOSED WEATHERHEAD . E E— EXISTING FIBER f ANIFI P. c CIV EXISTING TELCO 1o.4WG0 T T T T T T EXISTINGr/J I t GUY WIRES FF S n J� o EXISTING FIBER Ckll I -H Y f- p EXISTING GUY WIRE II, CHECKED BY: JX PROPOSED RGS CONDUIT TO METER PROPOSED (1) 1/2" COAX IN 2" CONDUIT FROM RRH TO ANTENNA APPROVED BY: DPH PROPOSED FIBER IN PROPOSED FIBER DEMARC BY i 2" U-GUARD /' SUBMITTALS FIBER PROVIDER O 15' AGL I / m PROPOSED FIBER y my. MTE or-owl10F1 or N PROPOSED AC/DC CONVERTER (FRONTHAUL & BACKHAUL) PROPOSED RGS CONDUIT PROPOSED LESSEE t1 (1) AWS RRH PROPOSED LESSEE 60A FUSED PROPOSED SAR-0 1 ' I DISCONNECT & SURGE ARRESTOR 11 0 7/73/201 IFASE D01Btf JS PROPOSED LESSEE METER 0 w ' af _ SITE NAME: W � - - EXISTING UTILITY N ANDOVER SC20MA POLE MECO #1 0 5' TO 8'-6" (AGL) m C7 SITE ADDRESS: IN ACCORDANCE WITH EXISTING UTILITY POLE 1-99 BANNAN DR. UTILITY COMPANY REQUIREMENTS a MECO #1 NORTH ANDOVER, MA 01845 v 1 O GROUND LEVEL S+EETTE ELEV. = m 0'-0"t (AGL) 201'-0"t (AMSL) =IT '' ELEVATION & PHOTO �_..'OPOSED GROUND ROD SHEET NUMBER ELEVATION 1 GRAPHIC SCALE 0 1'-4' 2'-8" 5'-4' 8'-0' L-2 22x34 SCALE: 3/8"=1'-O" L-2 EXISTING PHOTO DETAIL 2 11x17 SCALE: 3/16"=1'-O" SCALE: N.T.S L-2 LEASE EXHIBIT NOTES �4 THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND 1. AN ANALYSIS OF THE CAPACITY OF THE EXISTINGIS INTENDED TO PROVIDE / m E TO SUPPORT THE PROPOSED LO REGARDING THE LOCATION AND GENERAL ZE NOF TH TION �UNOT RBEEN COMPLETED BY HUDSON DESIGN G PROPOSED WIRELESS COMMUNICATION FACILITY. THE GROUP, LLC. DRAWINGS ARE SUBJECT TO CHANGE / x SITE LAYOUT WILL BE FINALIZED UPON COMPLETION PENDING OUTCOME OF A STRUCTURAL ANALYSIS. 02 W OF SITE SURVEY AND FACILITY DESIGN. EXISTING OVERHEAD 2. SHOP DRAWINGS OF FINAL EXTENSION AND/OR WIRES BELOW / Cn ANTENNA MOUNT TO BE PROVIDED TO ENGINEER OF /o Q RECORD PRIOR TO CONSTRUCTION. EXISTING UTILITY POLE J MECO #1 / Hudson D a Design GroupLLc PROPOSED LESSEE (1) ANTENNA 15"0x24.2H 1600 OSGOOD STREET BUILDING 10 NORTH,SURE 3090 TEL:19 781 557-5553 N.ANDOVER,MA 01845 FAX:19781336-5586 EXISTING OVERHEAD WIRES BELOW cra PROPOSED LESSEE • ,p1 14!5 (1) AWS RRH 9 � U Z` • t y o GRAPHIC SCALE 0, Z RRH DETAIL PLAN 4 0 .5 1 2 3 FEET Jlj 22x34 SCALE: 1"=1'-0" L-3 0\ 11x17 SCALE: 1/2"=1'-0" �, OF /*s, PAI IFI P. KGs �t PROPOSED ANTENNA C CI`� Io.4 )7' 0 '�Or �FG1S TC � r � PROPOSED CHECKED BY: JX M1. LESSEE (1) m SECONDARY ANTENNA ? - ?N APPROVED BY: DPH iv 1 15.1"Ox24.2"H N I FIBER SUBMITTALS FIBER FRONTHAUL GRD. & BACKHAUL w REV. a'TE DESCRp ON Ilf Qom°' SAR-O p UP COMMSCOPE o MC-MNT-TOP 04 _ O MOUNTING KIT o a a /�s/�I V"Mw Ii � N c=if - SITE NAME: lu Llt, N ANDOVER SC20 c4_ AC/DC CONVJERTER MA ANTENNA WITHOUT GPSy 4� # SITE ADDRESS: PROPOSED Z 60A SERVICEo 1-99 BANNAN DR. r+ POFIBLE-TOP EQUIPMENT NORTH ANDOVER, MA 01845 POLE-TOP EXTENSION 7/8'-14 THREADED STUD FOR ANTENNAMOUNTINGRADIO UNIT �ME FLAT WASHER DIMENSIONS: 37"Hx11"Wx6"D EQUIPMENT DETAILS LOCK WASHER WEIGHT: 55 LBS SMALL CELL CANTENNA METER SOCKET DIMENSIONS: 15.1"0x24.2' 7/8'-g HEX NUT WEIGHT: 22 LBS SHEET NUMBER ANTENNA MOUNTING —� ANTENNA DETAIL G RADIO DETAIL z DETAIL 3 GENERAL WIRING DIAGRAM 5 SCALE: N.T.S SCALE: N.T.S L-3 SCALE: N.T.S L-3 SCALE: N.T.S L-3 H 1 =99 BANNAN DR . , NORTH ANDOVER , MA01845 X1 I N ANDOVER SC20 MA W cn W J Hudson b Design GroupacRL D 1600 OSGOOD STREET ., BUILDING ZONORTH,SUITE 3090 TEL(978)557-5553 - N.ANDOVER,MAO 1945 FAX:(978)336-5586 f, r O A IBJ':F I P. G1 10 at � I 4�7�0 �O AS'iSTt�FO SSiot4A� �pC CHECKED BY: JX APPROVED BY: DPH SUBMITTALS t�., --•-• • FO. [ATE DESCFAMM Bi • • • - .• o /as/zm LEASE E:aW Is SFE NAME: NAN DOVER SC20 MA ,a SITE ADDRESS: 1-99 BANNAN DR. NORTH ANDOVER, MA 01845 o „ .. - a_- O 1 •• SHEET Trr E KEY PLAN 1452 Uq_ �C) Z�? Z SHEET NUMBER H KEY PLAN 1 _ SCALE: N.T.S L-1 APPROXIMATE LAT: N42' 40' 23.68- COORDINATES: LONG: W71' 05' 30.92' ' NOTES; LEASE EXHIBIT 1. AN ANALYSIS OF THE CAPACITY OF THE EXISTING THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND m STRUCTURE TO SUPPORT THE PROPOSED LOADING IS INTENDED TO PROVIDE GENERAL INFORMATION HAS NOT BEEN COMPLETED BY HUDSON DESIGN REGARDING THE LOCATION AND SIZE OF THE X GROUP. LLC. DRAWINGS ARE SUBJECT TO CHANGE PROPOSED WIRELESS COMMUNICATION FACILITY. THE W PENDING OUTCOME OF A STRUCTURAL ANALYSIS. SITE LAYOUT WILL BE FINALIZED UPON COMPLETION OF SITE SURVEY AND FACILITY DESIGN. W 2. SHOP DRAWINGS OF FINAL EXTENSION AND/OR ANTENNA MOUNT TO BE PROVIDED TO ENGINEER OF Q RECORD PRIOR TO CONSTRUCTION. APPROXIMATE LAT: N42' 40' 23.68" LU COORDINATES: LONG: W71' 05' 30.92' Hudson TOP OF PROPOSED ANTENNA Design Groupuc D ELEV.= 37-0 f AOL 238'-0't (AMSL) -PROPOSED ANTENNA _ _ PROPOSED LESSEE (1) 1600 OSGOOD STREET ELEV.= 36'-0't (AGL) ANTENNA 15.1'0 X 24.2"H BUILDING 20 NORTH,SURE 3090 TEL:19781557-5553 237'-0-* (AMSL) ---- N.ANDOVER.MA 01845 FAX:(978)336-5586 .PROPEXISTING PRIMARY POWER EXTENSION SED 5'-0'H FIBERGLASS SS EXISTING SECONDARY POWER EXTEN EXISTING PRIMARY R E E POWEf ti TOP OF EXISTING UTILITY POLE ELEV.= 29'-6"f (AGL) EXISTING GUY WIRE EXISTING TELCO 230'-6"t (AMSL) i EXISTING SECONDARY OF r, POWERS.S' PROPOSED WEATHERHEAD �� 9% E E j \ C'ANI 1 P. GJ EXISTING FIBERIV Z i 1 �f i c Cll\� EXISTING TELCO T T T � 6 g, 11 o.4 7 0 T T --� �� �� T a EXISTING GUY WIRES F�r f,ti p * EXISTING FIBER p EXISTING GUY WIRE CHECKED BY: JX m PROPOSED FIGS CONDUIT TO METER PROPOSED (1) 1/2' COAX IN 2' CONDUIT FROM RRH TO ANTENNA \ APPROVED BY: DPH PROPOSED FIBER IN PROPOSED FIBER DEMARC BY 2' U-GUARD SUBMITTALS FIBER PROVIDER O 15' AOL ate a PROPOSED FIBER DECRI1710 BY PROPOSED AC/DC CONVERTER (FRONTHAUL do BACKHAUL) `\� PROPOSED FIGS CONDUIT PROPOSED LESSEE (1) AWS RRH 7' PROPOSED LESSEE 60A FUSED PROPOSED SAR-0 1 DISCONNECT do SURGE ARRESTOR PROPOSED LESSEE METER 10 /za/zoT overt is w a. SITE NAME N ANDOVER SC20 EXISTING UTILITY w MA POLE MECO #1 5' TO 8'-6' (AGL) m SITE ADDRESS: IN ACCORDANCE WITH EXISTING UTILITY POLE 1-99 BANNAN DR. UTILITY COMPANY REQUIREMENTS < MECO #1 NORTH ANDOVER, MA 01845 v O GROUND LEVEL SHEET TITLE ELEV. = 0'-0"f (AGL) 1 I ISI(—�1 j1- 20t'-0"t (AMSL) I I I i I�I ELEVATION & PHOTO lw=II ,,I �IIIIT I" PROPOSED GROUND ROD SHEET NUMBER ELEVATION 1 GRAPHIC SCALE 0 1'-4' 2'-8' 5'-4° 8'-0' �_Gn 22x34 SCALE: 3/8"=1'-O" L-2 EXISTING PHOTO DETAIL 2� 11x17 SCALE: 3/16"=1'-O" SCALE: N.T.S L12 LEASE EXHIBIT NOTES THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND 1. AN ANALYSIS OF THE CAPACITY OF THE EXISTING IS INTENDED TO PROVIDE GENERAL INFORMATION STRUCTURE TO SUPPORT THE PROPOSED LOADING REGARDING THE LOCATION AND SIZE OF THE HAS NOT BEEN COMPLETED BY HUDSON DESIGN / PROPOSED WIRELESS COMMUNICATION FACILITY. THE GROUP, LLC. DRAWINGS ARE SUBJECT TO CHANGE �A SITE LAYOUT WILL BE FINALIZED UPON COMPLETION PENDING OUTCOME OF A STRUCTURAL ANALYSIS. e W OF SITE SURVEY AND FACILITY DESIGN. EXISTING OVERHEAD Uj 2. SHOP DRAWINGS OF FINAL EXTENSION AND/OR WIRES BELOW / ANTENNA MOUNT TO BE PROVIDED TO ENGINEER OF e a RECORD PRIOR TO CONSTRUCTION. Ljj EXISTING UTILITY POLE J MECO #1 / Hudson D Design Groupuc PROPOSED LESSEE (1) ANTENNA 15"0x24.2H 1600 OSGOOD STREET BUILDING N7 NORTH,SURE 3090 TEL 19781557-5553 N.ANDOVER,MA 01845 FAX:19781336-5586 EXISTING OVERHEAD WIRES BELOW 014 OM l } f PROPOSED LESSEE (1) AWS RRH t 145Uj 2' Z 0 o GRAPHIC SCALE �� z RRH DETAIL PLAN 4 0 .5 t 2 3 FEET N 22x34 SCALE: 1"=1'-0" L-3 11x17 SCALE: 1/2"=1'-0" OF f c t o J f ANIFI P. i�G^ MY �. 0 PROPOSED ANTENNA ` CIl` /7Q,� 4 S 0, PROPOSED CHECKED BY: JX ji LESSEE (1) O SECONDARY j ANTENNA ?N APPROVED BY: DPH N 15.1'0x24.2"H N Y FIBER SUBMITTALS FIBER FRONTHAUL GRD. & BACKHAUL RD- WE DESa " � ' � 3 a SAR-O p 0 '.' U V7 # c COMMSCOPE o i 1 MC-MNT-TOP N O MOUNTING KIT ,CL 0 r�u/pT LEM OHM � M f. NN 0 SITE NAME: @ N ANDOVER SC20 AC/DC CONVJERTER MA ANTENNA WITHOUT GPS 0 SITE ADDRESS: ° PROPOSED Z 60A SERVICEo 1-99 BANNAN DR. _ FIBERGLASS EQUIPMENT NORTH ANDOVER, MA 01845 � POLE-TOP EXTENSION 7/8"-14 THREADED STUD FOR ANTENNA SHEET TITLEMOUNTINGRADIO UNIT FLAT WASHEREQUIPMENT DETAILS DIMENSIONS: 37"Hx 11'111x6"D LOCK WASHER WEIGHT: 55 LBS SMALL CELL CANIENNA METER SOCKET DIMENSIONS: 15.1'0x24.2" 7/8"-9 HEX NUT WEIGHT: 22 LBS SHEET NUMBER ANTENNA MOUNTING �_� ANTENNA DETAIL 1 RADIO DETAIL 2 DETAIL 3 GENERAL WIRING DIAGRAM 5 SCALE: N.T.S L-3 SCALE: N.T.S L-3 SCALE: N.T.S L-3 SCALE: N.T.S L-3 0 Hudson D Design - " 16M OSGOOD STREET BUILDING 20 NORTH,SUrTE 3090 TEL:(978 557-5553 N.ANDOVER.MAO]845 FAX:(9781 336-55M zt- Y 3_ } s u t Y„r � t 4 v(M rte..,........ . _, • �• ! r �° .� .t_ a�_ , ,f� . ■ *� a w� s" ,;, ; —"�. . r., -• � .d;•~ PROPOSED LESSEE � ANTENNA MOUNTED TO It EXISTING UTILITY POLE 1 { A>, v. EXISTING-UTILITY POLE nMECO#24241 .y r a w„ �.€ w, PROPOSED LES i x 9 '— M NTEDTO EXISTING c '- a LI E _ ow jr L �., � r '' T�`'• ._�� '�� � °"' "ate+. t = e, I 'M,a r EXISTING'.UTILITY POLE MECO#242" 4� � -•'`��`•. 'r � -- -77 : 4 ■--- SITE NAME. ' v N ANDOVER MA s¢+. 4874 SALEM ST 1r ; SITE ADDRESS: >. NORTHD• a MAP DATA-c 2015:GOOGLE;EARTH COORDINATES:'APPROXIMATE LAT: N42' 40' 07.6" NOTES 1. AN ANALYSIS OF OF E)USTING • • • STRUCTURE TO SUPPORT THE PROPOSED LOADING •a• • • • • • ••• • HAS NOT • a• BY HUDSONDESIGN • • • • • • • • a• a aGROUP, DRAWINGS ARE SUBJECT TO CHANGE • • • a • • • i��`i PENDINGOUTCOME OF . • •• • • 2. SHOPDRAWINGS OF EXTENSION AND/OR •- • -• ` ANTENNA MOUNTTO BE • • • TO ENGINEER OF RECORD PRIOR TO CONSTRUCTION. • •• • • •. • I • • • • sos. I�t v y , fir, s+,•, f kHudson !D Desig•-�A u,.4 �fM� y Y° ,�;YEN. - `7 M.. 1600 �. -••• a• • �y`��Y�T ���� ` �� ,�� w�s�'A� �"J '.+`r•g,rfe �•1�`y irx 1 -•-• • -• �� � ti r, b,N�'"t'sar� . t�.,x. �� :'��• "��ii��x ;r.S'17%' �,, P -3• • z A t��.+�- YYf i j✓y�e' -i A,' `�it�•'aj;+e"�,ty� �;.:- •*r C}�, � j -•-• • .�1� •r J�y' 'R t'!`�� � .�' '* a Vii}""4i'� ,�pi�d 'r-rJ'y Y�y� ,�.,,= � -• • --•-• . • - - H s '��� }, �yµ!it �� � ,y_y.� � �""-�r''�_ `� +��� �b.s +. �`��st'ri �^ *' ?� � -•-• pli �'t �.L.+ �� ,.v �/�a, JS Ft d.4'r''Y}Ag�,,yw< ti:.� ,r, .�:..a7� �>i:. ��I -� •se!. k L..., x"43 �� :,�a' l�'{�" is''+ ?1[I,fs. T +w. ,�1�y�t tr...v7:sa - -•-• • • • � "=F+ ,f �"'A f�, $�:. •1 � � ' � �c s?;.aY 's+.t �,aig��, ��+�kwM4 �'d`.[aP�r� -• • • . _ I r } '+'_",�" \ .� ,,7 � >�+ c*'1+1R s�-sn,,,.� �a•.� +e 't p'a'•+,.a4., -�y _,�♦,- ,+ -••• • e,: .r *-+' .n ,'. r+ `?; } �t'f7' k. 'fd �y� 2.ata n. wA. W. PROPOSED SAR— • •� u"+f,•i3r t `` �� K4' 4. r t• J i; 41 xt.r r'. S/f� yy, • '7.s. ,.y.° ,r^a �_-- a, NINE 4 p r r SITE NAME-* �-r �� <��i�'1/! '��' -v ivy • ,�,,. ,' ��. �<" ��W' ,s�`k '07i_.r\ r..JF.'F .y�.{ `` f � dsi i1/.�.�` '� +I ` r✓d° frt. �''- s • ar ri 1, to • tr s H 1 • �{,� ` /cR/� �.� ms`s,�/ ; y - W. •-• • SrrE ADDRESS: , •ic f' 4, .. • � ♦' tet. I 874 SALEM ST NORTH ANDOVER, MA 01845 i'. f .� s- y a • •ti` '\tom. e �.��rfs, war+«;, ��.•� � �' � • • • N: �* ..>S a tit • • •• ffi s •',» , SHEET NUMBER LEASE EYHIRIIT NOTES: THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND 1. AN ANALYSIS OF THE CAPACITY OF THE EXISTING m IS INTENDED TO PROVIDE GENERAL INFORMATION STRUCTURE TO SUPPORT THE PROPOSED LOADING REGARDING THE LOCATION AND SIZE OF THE HAS NOT BEEN COMPLETED BY HUDSON DESIGN PROPOSED WIRELESS COMMUNICATION FACILITY. THE GROUP, LLC. DRAWINGS ARE SUBJECT TO CHANGE x SITE LAYOUT WILL BE FINALIZED UPON COMPLETION PENDING OUTCOME OF A STRUCTURAL ANALYSIS. W OF SITE SURVEY AND FACILITY DESIGN. EXISTING UTILITY POLE W 2. SHOP DRAWINGS OF FINAL EXTENSION AND/OR �. ANTENNA MOUNT TO BE PROVIDED TO ENGINEER OF m MECO #2424/1 RECORD PRIOR TO CONSTRUCTION. �'v -- � PROPOSED LESSEE (1) Q r ANTENNA 15.1'0 X 24.2H W o I I i PROPOSED LESSEE J (1) AWS RRH Hudson Design Group= 4R f tr 1600 OSGOOD STREET BUILDING 20 NORTH,SURE 3090 TEL:(9781557-5553 VN.ANDOVER,MA 01845 FAX:(978)336-5586 EXISTING OVERHEAD �--} WIRES BELOW S 4 14'52' GRAPHIC SCALE al "0 s LU RRH DETAIL PLAN 4 0 .5 1 2 3 FEEr _ > > y 22x34 SCALE: 1"=l'-O" L-3 0F &IG A �Z ~z 1107 SCALE: 1/2"=1'-0" P S9 L-AI\:IEL P. Gn • �Ji � , � ���,1 1. e -6 PROPOSED ANTENNA Cy CIV 4 • S 0.4 )7iC IT ' PROPOSED /ONP,_ E LESSEE (1) ANTENNA CHECKED BY: JX a 15.1"Ox24.2"H SECONDARY 'N JAPPROVED BY: DPH dFIBER C4 SUBMITTALS FIBER FRONTHAUL GRD. & BACKHAUL Li REV' WE BY t 0z ► ' COMMSCOPE SAR-O U N MC-MNT-TOP MOUNTING KIT o> w 04 I 0 0 0 07/23/15 MRLM EXHIBIT CP SITE NAME NJ Ll N ANDOVER SC23 t AC/DC CONVERTER MA ANTENNA WITHOUT GPS + EXISTING UTILITY 1 POLE o cF Z SITE ADDRESS: 60A SERVICE o 874 SALEM ST EQUIPMENT NORTH ANDOVER, MA 01845 1 > 1_ 7/8'-14 THREADED N a STUD FOR ANTENNA MOUNTING 'c':)-a. NEET TITLE FIAT WASHER ww10 UNIT EQUIPMENT DETAILS LOCK WASHER SMALL CELL CANTENNA DIMENSIONS: 37"Hx11"Wx6"D METER SOCKET WEIGHT: 55 LBS DIMENSIONS: 15.1"0x24.2" 7/8"-g HEX NUT WEIGHT: 22 LBS - SHEET NUMBER ANTENNA MOUNTING �_� ANTENNA DETAIL 1 RADIO DETAIL 2 DETAIL 3 GENERAL WIRING DIAGRAM SCALE: N.T.S L-3 SCALE: N.T.S L-3 SCALE: N.T.S L-3 SCALE: N.T.S L-3 _ .•- p k 4 . y BUILDING0 7 N.ANDOVER,MA01945 FAX:(978)336-5586 F ._ ' f WAL d 4. J - x w < r AT. 1Lrrc ..a , ;_ r �„ •+w.+rd:.r�" e r � t. -J• F .Q' Mv'<.i. .n,� s'` w! _. 1 as - ' ^m^ _--} '�^v. ,« ��,� •!; PROPOSED LESSEE q ANTENNA MOUNTED TO I/ t EXISTING UTILITY POLE r ** ��« . , ,,t_ EXISTING UTILITY POLE . ' _ ' :�' saMECO#2424/1 , .', ac LESS E,, ' 'JFa a + «` MOUNTED,—TO EXISTING' UTIGTY POLE U. < a x r ; t *� t 4 EXISTING UTILITkY POLE ',. 'f MECO#242 - 4` .. _.� .__+'__ _- _;-' .. • ._._ - .,>e--"� = _. w; '' ..;;may,"., ■--- t r a y c SITE NME* MA b o WE ADDRIM: a 874 SALEM ST NORTH ANDOVER, MA 01845 MAP DATA©-2015,GOOGLE EARTH L%z4bl Q Ul I Ike] ,. • 7 • 1. AN ANALYSIS OF OF EXISTING THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND • STRUCTURE TO SUPPORT THE PROPOSED LOADING IS INTENDED TO PROVIDE GENERAL •- • '•-• • HAS NOT • 7• BY HUDSONDESIGN REGARDING • • • SIZE OF • '•'• 7• 7 7GROUP. DRAWINGS ARE SUBJECT TO CHANGE PROPOSED WIRELESS COMMUNICATION • `` PENDING OUTCOME OF - ANALYSIS. • • UPON COMPLETION OF SITE SURVEY AND FACILITY DESIGN. 2. SHOP DRAWINGS OF EXTENSION AND/OR •- • -• 1 rANTENNA MOUNTTO BE PROVIDED TO ENGINEER OF RECORD PRIOR TO CONSTRUCTION. APPROXIMATE LAT: N4Z 40' 07.6* ' SHY, I • • ••• • ru ?i* Iks t�+ !��T;+rb Ir ' iy. ??•n r f fir} • • , Design 1 M i y . �'ixG��p� ,�, I 3 j"6: Y '•�.l} '✓� +�d�/t>� � �4tU�i'` `r�'L'��'��y '�drr•,.�".� �aG ; '"��� c� ��,,;e1�,11��'t'�'��J4„•��. 1� �x r �,:riN� LTJ �'y'k�yp+ �e��r !T� •'• • '• 7 • H a + '��S ���f i � Y' k ..: s�E" • it �% • •• • .. � {'+' n ,��I\ r� fit �.• �•/ ^ ,�,I. �r'� - _ _ s �y,}�: •111'^^' ,./yt �i�.,�:' Y � t �'� �. y�Jl�� • • mss-,r r • .i '4#4- s *.�4Civ ..1�'r%; -,. F ��3*T•�rsA'� f• .E . + ,r. t.'h rW'�Ls�A"�,i' i' "JY+ 1��� •4-`R.�; ry�,;r, _ C !� li �, ,�.fj`a-*.s.➢ .G. ,� .,'f 4 ':��:� -4 •St._ �$. a ��a.Qht� / � � ,41 � I J#$,t .!•� '•* rt1". ` �.�°�� �.s�ia ¢���;`Xl�' �p� Mf��,G� � /' •-• • `� ,M Lc �u'R/ct +� oqf 5 i �y£•�q_3�. .. a ?mob' / / •'• • :7- •7 . 'H �r�� 31, r . Y,l +may,. ,. ,i� tv... pis• d �•L¢ rpm: ",rio,r „r�,3r” w+ ••• • f x.'4..9 "q ��•r,� ,� y�ww+'�• ,� „ 4 �h '• tea'+ ��C&a 2 +^..• ki � .3.( 1 �! ♦ i� r ` S� — K. Wll V, IWA +W Y III II '�',. vk} 'e�x`'�'�y�`�! r Y� x 'SEs. ..^h F,�I �y�++{u a!t+F.,y ,..`.•'M�y}'�' ,r r F''x s �--- ..•.• 7• • PROP _••• 7• 444iff 1�$ �.� •T- # �J,i,4, ice .- �� 4 fey 1 ,, x' - .01.AR "1T , `k.E _,�,• ��,a� 1{t,-, .. 1�4.D fW� .� -JF' fY.. + 3. .,r. k-K .L ✓::. ■-_-_. c �� ��,di !�°,`• ,F��41ir�'�i` r- - � � 3�'•-'•".• �T,y-�"*9 � �. •vat �''a`r '0�® r/ ' SrrE ADDRESS: 874 SA _ -,; r.� t .^.' r I� 4 -'r •�i�. 'f y<" w'. .. SITE NAME., MA _ • »• 1♦�..*4 Yw1 � u,�rgiyrf� '•/ -` �.'F... j/Y .* y.y ',1• LEM ST NORTH ANDOVER, MA 01845 Jto rt„ w £ -'' �=jf/ . .. inti t-- w , ya' .,I . �S•3` J v ,,� t�` ,+ �� _• • • • — I - j'_r'J x � ii•` N MSV /�►�1. !,' `� I y���� SHEET ELEVATION & PHOTO '• • '•• ,. -.�. it { a-J,: L. 4 J. .} SHEET &. 10 LEASE EXHIBIT NOTES: - - - - THIS LEASE PLAN IS DIAGRAMMATIC IN NATURE AND 1. AN ANALYSIS OF THE CAPACITY OF THE EXISTING m IS INTENDED TO PROVIDE GENERAL INFORMATION STRUCTURE TO SUPPORT THE PROPOSED LOADING REGARDING THE LOCATION AND SIZE OF THE HAS NOT BEEN COMPLETED BY HUDSON DESIGN PROPOSED WIRELESS COMMUNICATION FACILITY. THE GROUP, LLC. DRAWINGS ARE SUBJECT TO CHANGE x SITE LAYOUT WILL BE FINALIZED UPON COMPLETION PENDING OUTCOME OF A STRUCTURAL ANALYSIS. w OF SITE SURVEY AND FACILITY DESIGN. 2. SHOP DRAWINGS OF FINAL EXTENSION AND/OR y EXISTING UTILITY POLE LU ANTENNA MOUNT TO BE PROVIDED TO ENGINEER OF MECO #2424/1 I) RECORD PRIOR TO CONSTRUCTION. �w '— PROPOSED LESSEE (1) Q r p ANTENNA 15.1'0 X 24.2'H W �O PROPOSED LESSEE J (1) AWS RRH Hudson r Design Groupuc qQ rt r r rr, 0 1600 OSGOOD STREET BUILDING 20 NORTH,SUITE 3090 TEL:(978)557-5553 UN.ANDOVER,MA 01945 FAX:1978)336-5586 51 ±*D EXISTING OVERHEAD �! WIRES BELOW �4 w 14'52' GRAPHIC SCALE 1s 1"0 j `—'z� I w� RRH DETAIL PLAN 4 0 s 1 2 3 FEET p 22x34 SCALE: 1"=l'—O" L-3 QF iqq Z H-z 11x17 SCALE: 1/2"=1'-0" ['AfJIF L o 1�,-_; •^ �_ t � i PROPOSED ANTENNA PROPOSED UrdA� LESSEE (1) ANTENNA CHECKED BY: JX 11 15.1"0x24.2"H 2N SECONDARY APPROVED BY: DPH s N N f FIBER .�P .� SUBMITTALS FIBER FRONTHAUL GRD. / & BACKHAUL Lj REV- DATE DMCF MON er s a # � COMMSCOPE SAR-O U N MC—MNT—TOP L a, MOUNTING KIT > •+ 0 d 10 07/23/15 FOR LEASE DHW CP If 79 �� NJ-TF- SRE NAME N ANDOVER SC23 AC/DC CONVJERTER MA ANTENNA WITHOUT GPS ' • +' EXISTING UTILITY POLE o SITE ADDRESS: ST a 60A SERVICEQ 874 NORTH ANDOVER,MA 01845 I EQUIPMENT 7/8"-14 THREADED STUD FOR ANTENNA W) T- _ MOUNTING SHEET TmE FLAT WASHER RADIO UNIT EQUIPMENT DETAILS LOCK WASHERMETSOCKE SMALL CELL CANTENNA DIMENSIONS: 37'Hx11`Wx6"D DIMENSIONS: 15.1"0x24.2" 7/8"-9 HEX NUT WEIGHT: 55 LBS WEIGHT: 22 LBS SHEET NUMBER ANTENNA MOUNTING �—A ANTENNA DETAIL 1 RADIO DETAIL 2 DETAIL 3 GENERAL WIRING DIAGRAM 5v{ SCALE: N.T.S L-3 SCALE: N.T.S L-3 SCALE: N.T.S L-3 SCALE: N.T.S L-3