HomeMy WebLinkAboutMiscellaneous - 10 RUSSETT LANE 4/30/2018 (2)A
N
O
o
b co
o cI
o m
b
o z
PM
0
e
V 4
o Lor � 4 - �aT
a.
�p 30
_Te 54 �Lo-r- tam :.
•_ . _ iG. ifs _ � +(''�'I� � --- - - --'.._ �._: T-
-{-:_._+
tip aid t�t�( (6272
{ _ ...._.... t'i3L•3
1-4
ris
ld
toxo �ia�.ar' .. '�. l\� t`� _.__ •._ _ � •-- - .. ---. .._ .
N
!?4 ..�.._..
1? 4& Id�
CCN OF
FRANK
` C.
GELINAS
pNo. 227380 Q .4 .0
9 �FSSf0NM
t ,C A
PAT
3/tZ li',
3'19 j'13
'�4�t�raS�on
Zo vvti r�
? 4,H a.
f3 off vl
DGGIS f3 A%( A - (r, rA%;I
_Te 54 �Lo-r- tam :.
•_ . _ iG. ifs _ � +(''�'I� � --- - - --'.._ �._: T-
-{-:_._+
tip aid t�t�( (6272
{ _ ...._.... t'i3L•3
1-4
ris
ld
toxo �ia�.ar' .. '�. l\� t`� _.__ •._ _ � •-- - .. ---. .._ .
N
!?4 ..�.._..
1? 4& Id�
CCN OF
FRANK
` C.
GELINAS
pNo. 227380 Q .4 .0
9 �FSSf0NM
t ,C A
r--T
i N
N�j�'�
t
t N q
y
oil •� d .
d• .
o
�
1
s
t
t N q
y
oil •� d .
d• .
Lot 14 Russett Lane
Ben Osgood
1�
APPLICATION FOR SEWAGE DISPOSAL INSTALLATION
HEALTH DEPARTMENT - NORTH ANDOVER, MASS.
I herebyI!8V 1L%'se*t eor a permit for a sewage disposal installation at
. I will install this system in ac-
cordance with all the laws of the Commonwealth of Massachusetts and regulations of
the Board of Health of the Town of North Andover.
Further, I will construct the house sewer of bell and spigot pipe, the minimum
diameter being 4 inches, and will maintain a minimum grade of 1% until 10 feet pre-
ceding the septic tank, wh9i2!;6the grade shall not exceed 29o. I.will install a con-
crete septic tank of in size. A manhole (s) permitting easy cleaning
will be provided with removable cover (s) of iron or concrete within 12 inches of
the ground surface. I will provide subsurface disposal field with 4 inch perforated
or open jointed pipe and laid in a series of trenches, the bottom of which will pro-
vide a minimum of 300 lineal (square) feet of effective absorption area.
The pipes will be laid on a 6 inch layer of washed gravel or crushed stone ranging
in size from 3/4 to 1-1/2 inches (dia.) and the pipes will be surrounded by similar
material to a height of 2 inches above the crown of the pipe. The joints of these
pipes will be protected from clogging and before filling the trench, 2 inches of
gravel or stone 1/8" to 1/4" (dia.) will be placed over the course gravel or stone.
The disposal field will be installed at a grade of 4 to 6 inches/100 feet. No single
the line will exceed 100 feet in length and in any case, two lines of tile will be
installed. A minimum of 6 feet will be maintained between the center lines of the
disposal field trenches and the average depth of trench shall not exceed 36 inches.
No part of the installation will be less than 100 feet from any private water supply,
25 feet from any stream, 20 feet from any dwelling or 10 feet from any property line.
I further agree not to cover any portion of this installation until approved by the
inspection officer, as provided below, and to incorporate any additional requirements
that may be attached to the permit. Plot Plans must be submitted with application.
2 foot gravel bed
DATE 71/6/71
Signature of Applicant
I hereby issue the above permit for the Board of Health of the Town of North
Andover, Massachusetts.
DATE 11/6/71
Signature of Health Agent
I have inspected the uncovered system indicated above and find everything done
as described.
DATE
Signature of Inspecting Officer
Percolation Test 7 Minutes Soil Clay
Garbage Grinder
BOARD OF HEALTH
TOWN OF NORTH ANDOVER, MASS.
N
1.
NAME
OLD NORTH ANDOVER REALTY TRUST DATE JULY 29, .1971
2.
ADDRESS RUSSET LANE LOT NO.� l_ TEL 475-6333
3.
NO. OF BEDROOMS 5 DEN YES NO X
4.
GARBAGE GRINDER YES NO X
5.
SHOW
DIMENSIONS OF HOUSE
6.
SHOW
DISTANCES OF HOUSE TO ALL PROPERTY LINES
7.
SHOW
DIMENSIONS OF LOT
8.
SHOW
LOCATION AND SIZE OF SEPTIC TANK OR CESSPOOL
9.
NOTE
LOCATION AND DISTANCE OF WELL FROM SEWERAGE SYSTEM
10.
SHOW
LOCATION OF BROOKS, STREAMS, DITCHES, LEDGE OUTCROP, ETC.
11.
SHOW
DISTANCE OF SEPTIC TANK OR CESSPOOL FROM HOUSE
NOTE: LOCAL REGULATIONS SHOULD BE READ CAREFULLY.
Two-family House
,j1 ^K
0
0-04
7�'A3��
BOARD OF HEAL'T'H I �
TOWN OF NORTH ANDOVER, MASS. �!
1. NAME_ Old North Andover Raalty Trust DATE
2. ADDRESS Russet Lane LOT NO. 14 TEL.
3. NO. OF BEDROOMS DEN YES NO
4. GARBAGE GRINDER YES NO
5. SHOW DIMENSIONS OF HOUSE
6. SHOW DISTANCES OF. HOUSE TO ALL PROPERTY LINES
7. SHOW DIMENSIONS OF LOT
8. SHOW LOCATION AND SIZE OF SEPTIC TANK OR CESSPOOL
9. NOTE LOCATION AND DISTANCE OF WELL FROM SEWERAGE SYSTEM
10. SHOW LOCATION OF BROOKS, STREAMS, DITCHES, LEDGE OUTCROP, ETC.
11. SHOW DISTANCE OF SEPTIC TANK OR CESSPOOL FROM HOUSE
NOTE; LOCAL REGULATIONS SHOULD BE READ CAREFULLY.
A_. I - '40
BOARD OF HEALTH OF NORTH ANDOVER, MASSACHUSETTS
SEWAGE DISPOSAL
DATE 11/6/71
NAME OF APPLICANT Old North Andover Realty, Trust
LOCATION Lot #111 Russet Lane
Address of lot no.
BUILDING: Dwelling X Other
SYSTEM: New x Repair
GENERAL DESCRIPTION OF LAND High
SUBSOIL: Clay__ Gravel Sand
PERCOLATION TEST 7 minutes per inch.
MINIMUM INSTALLATION RECOMMENDATIONS
CONCRETE SEPTIC TANK 1.2:50; gallon capacity.
LEACH FIELD 3On lineal feet of drain pipe.
21 gravel bed
William J. Driscoll, Engineer
Board of Health