Loading...
HomeMy WebLinkAboutMiscellaneous - 106 MARBLEHEAD STREET 4/30/2018 106 MARBLEHEAD STREET 210/009.0-0021-0000.0 i 1 1 N21 904 Date...........`...d................ t NCRTM'9 TOWN OF NORTH ANDOVER p PERMIT FOR WIRING ��SSAC/Ius This certifies that ..... rr ' ....�-d.! •- —' has permission to perform wiring in the building of.... ............... ........................ .........................................................,Nbrth Andover,Mass. Fees.'... ...... Lic.N6.� ... .......................... } ELECTRICAL INSPECTOR 10/06/9916:20 50,00 RAID WHITE: ApplicaW06/99 UMURY: Buildirsop*t. PAID PINK:Treasurer ThEOOMM IONW1 A' LTHOI,'MAS.1` MUSED Office Use only DEPARTM VTOFPUBLIC&4FM Permit No. 11?6 BOARD OF FIRE PREVEMYONREGUl 4 TIOAN 527 CMR 12:M Occupancy&Fees Checked UV4PPUCATTONFOR PERI�V.QTTO PERF'ORMELECTRICAL WORK ALL WORK TO BE PERFORMED IN ACCORDANCE WITH THE MASSACHUSSTS ELECTRICAL CODE,527 CMR 12:00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Dates/ �,�,^� Town of North Andover To the inspector of Wires: The undersigned applies for a permit to perform the electrical work described below. Location(Street&Number) /D Owner or Tenant Owner's Address Is this permit in conjunction with a building permit: Yes No (Check Appropriate Box) Purpose of Building 7-,A-j a- Utility Authorization No. d Existing Service 1�-D D Amps/Zo/ 7-46Volts Overhead Underground Q No.of Meters New Service Z-O Amps/Zo/ a Volts Overhead Underground Q No.of Meters Number of Feeders and Ampacity 3120 ty 1 Location and Nature of Proposed Electrical Work -46--p-^� .o�,ceVie- o,"__� C�o> r arract/ — No.of Lighting Outlets No.of Hot Tubs No.of Transformers Total KVA No.of Lighting Fixtures Swimming Pool Above Below Generators KVA ground ground No.of Receptacle Outlets No.of Oil Burners No.ofEmergency Lighting Battery Units No.of Switch Outlets No.of Gas Burners No.of Ranges No.of Air Cond. Total FIRE ALARMS No.of Zones Tons No.of Disposals No.of Heat Total Total No.of Detection and Pumps Tons KW Initiating Devices No.of Dishwashers Space Area Heating KW No.of Sounding Devices No.of Self Contained Detection/Sounding Devices No.of Dryers Heating Devices KW Local Municipal Other Connections No.of Water Heaters KW No.of No.of a Signs Bailasis No.Hydro Massage Tubs No.of Motors Total HP OTHER IIS1Il'd[ICeC PtIlStl�bthet8�[HT1d�SQ�IVI �if'ilHalL3W5 Iha%eaamatLiabtidyknzaroePdLyilt Cor kt CovwdWc nits e*iv2kt YES NO ■f Ilmesknibodvalidptoof iothe0ffi=YES t,/11NO IfyculmedaiWYES,pkm thetypecfooraaWbyd�adalgthe amcbox LTJ INSURANCE BOND O HiER (Pl mSpe*) Esftn*dVaiudE6chcalWoc$ WakloStat 0 hTxy,D 7Z; �y(" RWgh /0 _ 5y rbc FM SigwdutldaMRw1ftmcfpajtay. �'"`�'��-Q �Q" FIRMNAME LiorneNa Doff M �.t�a�. ,1Iioe eNo d Z 3 ... / BtikmTdNo. 979 -_._ Addrm.1..�s �• ' 1 �i �t AIL TdNa OWNER'SRsSURANCEWALVFR;IamawatethattheLiarnedoesesnot staane arilsSt i astacpmedhylVf G Laws anddit.mysigs cnthispem*t nwai�zthiste*imiertt (Please check one) Owner Agent Telephone No. PERMIT FEE For A.M. Date Time P.M. FIWHILE YOU WERE OUT :2�M Of O Phone ❑Fax ❑Mobile Area Code Number Extension TELEPHONED PLEASE CALL CAME TO SEE YOU WILL CALL AGAIN WANTS TO SEE YOU URGENT RETURNED YOUR CALL SPECIAL ATTENTION Me ge la _ /vs-- di Signed 09/20/1999 11:47 50879400'_2 BELAIR & ZIPE70 PAGE 02 09/16/1999 01:04 5086835595 JJ5 WAGE 01 > UTGAaa aur cnarr Dab,: Q�lr Rom._._._, Dnwri poe Cityzown of �'"' I�ssasmsa M,p A VRWArQ ►�..ago , ,e C_. if C)pj fq We 40 w.r,p, /fr '0910C ANrs t.vp/lbse ltiv6t. MAP 49P te:+r it I ,.x• 2 std. X ?r3 4 b g/) - 0 (qS hereby cetti tb�t tlu abo•t Mart�ap Inspeetlsa Plaa�i pvspdtad iar►�s iu eougctlaa�h a ao�v Moetp�a end is nut anta�ded or�xct�cel to It a praperiy line a IWA covey,h ieam bo vied IN atabtishiq featt,btdp.M a bULdiq lima. No rtlportsittility is MINOed to tht t3nz, wnr,vm4mt K buys.Mw(vaatiea of the MOW W44**)w shut herein wer in eettipliLwe willa the lout spplkabw iesim bylaws is c=rea _ 'bo cat<etrMN&with teepW to barimW AmmmW m4WMMA to!at rsaes ar is exempt Eoet vlolatton endorcemeut n www Mass G.L. Itis Vlt Chep.4".aee.7,Wkw oOmwin tbor+rtt bamte.30"t brit s)1ks in a Codd gme ted Zesr:_�.` I IN' laatf en FARM Map Caassnttttity.PwI N„., 2gAA 000*ge r)ewd: job No. r .A Town ®f North Andover AORTN OFFICE OF �?ytt' .o "'e�° COMMUNITY DEVELOPMENT AND SERVICES 027 Charles Street North Andover, Massachusetts 01845 �yq°^•,t� "��y WILLIAM J. SCOTT - SSAc"use Director (978)688-9531 Fax(978)688-9542 December 1, 1999 Mr.&Mrs.Richard L.Heider 106 Marblehead Street North Andover MA 01845 Re: 106-106A Marblehead St Fire Dept Requested Inspection Dear Mr.&Mrs.Heider: After inspecting the electrical panels at the above address,I found two(2)violations,which must be corrected immediately. The National Electrical Code 1999 1. Article 100—Definitions Section A General states: O Accessible,readily(readily accessible)capable of being reached quickly for operation -renewal,or inspections without requiring those to whom ready access is requisite to climb over or remove obstacles or to resort to portable ladders,etc. 2. Article 230 Section 72 Access to Occupant In a multiple occupancy building,each occupant shall have access to the occupant's service disconnection means. Please have your electrician apply for a permit at the building department and call for an inspection when the work is complete.Call me at 688-9545. Very truly yours, James DeCola, Electrical Inspector JD.Jrn Return Receipt P 186 642 100 File: 106 Marblehead St O BOARD OF APPEALS 688-9541 BUILDING 688-9545 CONSERVATION 688-9530 HEALTH 688-9540 PLANNING 688-9535 ARTICLL 100—DLPINITIONS 70_19 CHAPTER 1 I Attachment Plug (Plug Cap) (Plug). A device that, by OGeneral insertion in a receptacle, establishes a connection between the conductors of the attached flexible cord and the conduc- tors connected permanently to the receptacle. Article 100—Definitions Automatic. Self-acting,operating by its own mechanism Scope. This article contains only those definitions essential when actuated by some impersonal influence, as, for exam- to the proper application of this Code. It is not intended ple, a change in current strength, pressure, temperature, or to include commonly defined general terms or commonly I mechanical configuration. defined technical terms from related codes and standards. Bathroom. An area including a basin with one or more In general, only those-terms that are used in two or more articles are defined-in Article 100. Other definitions are of the following: a toilet, a tub, or a shower. included in the article in which they are used but may be I Bonding (Bonded). The permanent joining of metallic referenced in Article 100. parts to form an electrically conductive path that will ensure Part A of this article contains definitions intended to electrical continuity and the capacity to conduct safely any apply wherever the terms are used throughout this Code. current likely to be imposed. Part B contains definitions applicable only to the parts of articles specifically covering installations and equipment Bonding Jumper. A reliable conductor to ensure the operating at over 600 volts, nominal. required electrical'conductivity between metal parts required to be electrically connected. A. General Bonding Jumper,Equipment. The connection between two or more portions of the equipment grounding conductor. Accessible(as applied to wiring methods). Capable of being removed or exposed without damaging the building Bonding Jumper, Main. The connection between the structure or finish, or not permanently closed in by the grounded circuit conductor and the equipment grounding I structure or finish of the buildin-. conductor at the service. Accessible (as applied to equipment). Admitting close - Branch Circuit. The circuit conductors between the approach; not guarded by locked doors, elevation, or other final overcurrent device protecting the circuit and the out- effective,means. let(s). t _=?- Accessible, Readily (Readily Accessible). Capable of Branch Circuit Appliance. A branch circuit that sup- being u PP p- . being reached quickly for operation,renewal,or inspections, plies energy to one or more outlets to which appliances are f: . without requiring those to whom ready access is requisite I to be connected, and that has no permanently connected to climb over or remove-obstacles or-to resort to portable lighting fixtures that are not a part of an appliance. ladders, etc. Branch Circuit General Purpose. A branch circuit that Ampacity. The current,in amperes,that a conductor can supplies a number of outlets for lighting and appliances. carry continuously under the conditions of use without ex- "` ceedin its.tem erature satin Branch Circuit, Individual. A branch circuit that sup- di P g• plies only one utilization equipment: ^. ._ Appliance. Utilization equipment, generally other than nindustrial,normally built in standardized sizes or types, that Branch Circuit,Multiwire. A branch circuit that con- sists.installed or connected as a unit to perform one or more of two or more ungrounded .conductors that have a functions such as clothes washing, air conditioning, food potential difference between them,and a grounded conductor g, deep frying, etc. that has equal potential difference between it and each un- grounded conductor of the circuit and that is connected to Approved. Acceptable to the authority having jurisdic- the neutral or grounded conductor of the system. tion. }ABuilding. A structure that stands alone or that is cut off skarel. A generic term for a group of nonflammable from adjoining structures by fire walls with all openings " syn thetic_chlorinated hydrocarbons used as electrical insu- therein protected by approved fire doors. lating.media. Askarels of various compositional types are used:::.Under arcing conditions, the gases produced, while Cabinet. An enclosure designed either for surface Co nststing.predominantly of noncombustible hydrogen chlo- mounting or flush mounting and is provided with a frame, 'riile'can.include varying amounts of combustible gases de- mat, or trim in which a swinging door or doors are or can nding;on the askarel type. be hung. ' ';cul=y`-.• -_ � a ATIO.NAL ELECTRICAL CODE 4>_.{ 1999 Edition ARTICLE_'10—SERVICES 76-67 permitted to be located remote from the other disconnectin> ?? means. f 20. In no case shall the ratin-g- be lower than specified in = (a), (b), (c). or (d). (b) Additional Service Disconnecting Means. The one or (a) One-Circuit Installation. For installations to supply more additional service disconnecting means for fire pumps, only limited loads of a single branch circuit th permitted by Section 230-2 shall be installed sufficiently r: ce for legally required standby,or for optional standby services f' disconnecting means shall have a rating of not less than serv115 Y amperes. remote from the one to six service disconnecting means for - ? normal service to minimize- the possibility of simultaneous interruption of supply. (b) Two-Circuit Installations. For installations consisting _ of not more than two 2-wire branch circuits, the service • disconnectingmeans shall have a rating (c) Access to Occupants. In amultiple-occupancy build- ing,each occupant shall have access to the occupant's service amperes. disconnecting means. Exception: In a multiple-occupancy building where electric (c) One-Family Dwelling. For aone-family dwelling, the service disconnecting means shall have a.rating of not less service and electrical maintenance are provided by the build- than 100 amperes, 3-wire. _ ing management and where these are under continuous building management supervision, the service disconnecting (d) All Others. For all other installations, the service dis-_ _ means supplying more than one occupancy shall be permit- tedconnecting means shall have a rating of not less than 60 s" to-be accessible to authorized management personnel amperes. onl y ' 230-80. Combined Rating of Disconnects. Where the ser- 1 230-74. Simultaneous Opening of Poles. Each service g means consists of more than one switch vice disconnecting k disconnect shall simultaneously disconnect all ungrounded or circuit breaker, as permitted by Section 230-71, the com- , ,. service conductors that it controls from the premises wiring bined ratings of all the switches or circui stet breakers used system.- shall not be less than the rating required by Section 230-79. 230-75. Disconnection of Grounded Conductor. Where 230-81. Connection to Terminals. The service conductors O the service disconnecting means does not disconnect the shall be connected to the service disconnecting means by grounded conductor from the premises wiring pressure connectors,clamps,or other approved means. Con- shall other means P -,� shall be provided for this purpose in the service equipment. nections that depend on solder shall not be used. «- A terminal or bus to which_all grounded conductors can be attached by means of pressure connectors shall be permitted 230-82. Equipment s for this purpose. _ - Connected to the Supply Side of Ser- k ` In a multisection switchboard, disconnects for the I pere Drs oto be co Only the following equipment shall be l nected to the supply side of the service I° grounded conductor shall be permitted to be in any section disconnecting means: f� othe switchboard, provided any such switchboard section is marked. 230-76. Manually or Power Operable. The service dis- (1) Cable limiters or other current-limiting devices II (2) Meters nominally rated not in excess of 600 volts,pro- connecting means for ungrounded service conductors shall consist of either (1) a manually operable switch or circuit Qided all metal housings and service enclosures are I' -rounded in accordance with Article 250 9 R breaker equipped with a handle or other suitable operating C means or. 2 a power-operated switch or circuit breaker (3) Instrument transformers (current and voltage), high- € n provided the switch or circuit p breaker can be opened by impedance shunts, surge-protective devices identified _ f _ - hand in the event of a power supply failure. for use on the supply side of the service disconnect, l _ t ~ load management devices, and surge arresters 230-77. Indicatin The service disconnecting means shall (4) Taps used only to supply load management devices, position. circuits for stand-by power systems, fire pump equip- plainly indicate whether it is in the open or closed 't ment, and fire and sprinkler alarms, if provided with service equipment and installed in accordance with 230-79. Rating of Service Disconnecting requirements for service-entrance conductors € Means. The ser- (5) Solar photovoltaic systems or interconnected electric vice disconnecting means shall have a rating not less than �the load to be carred,determined in accordance with Article power production sources (See Articles 690 or 705 as 4 applicable.) tr' k NATIONAL ELECTRICAL CODE I 1999 Edition k 1 'A