Loading...
HomeMy WebLinkAboutMiscellaneous - 115 HILLSIDE ROAD 4/30/2018 115 HILLSIDE ROAD 210/098.0-0046-0000.0 � l J & V Realty Lot A Hillside Rd. w APPLICATION FOR SEWAGE DISPOSAL INSTALLATION HEALTH DEPARTMENT - NORTH ANDOVER, MASS. I hereb�r make application for a permit for a sewage disposal installation at Lot A Hillside Road I will install this system in ac- cordance with all the laws of the Commonwealth of Massachusetts and regulations of the Board of Health of the Town of North Andover. Further, I will construct the house sewer of bell and spigot pipe, the minimum diameter being 4 inches, and will maintain a minimum grade of 1% until 10 feet pre- ceding the septic tank, where the grade shall not exceed 2%. I will install a con- crete septic tank of 100 in size. A manhole (s) permitting easy cleaning will be provided with removable cover (s) of iron or concrete within 12 inches of the ground surface. I will provide subsurface disposal field with 4 inch perforated or open jointed pif&ad l�id1 in a series of trenches, the bottom of which will pro- vide a minimum of see a ow, lineal (square) feet of effective absorption area. The pipes will be laid on a 6 inch layer of washed gravel or crushed stone ranging in size from 3/4 to 1-1/2 inches (dia. ) and the pipes will be surrounded by similar material to a height of 2 inches above the crown of the pipe. The joints of these pipes will be protected from clogging and before filling the trench, 2 inches of gravel or stone 1/8" to 1/4" (dia.) will be :placed over the course gravel or stone. The disposal field will be installed at a grade of 4 to 6 inches/100 feet. No single tile line will exceed 100 feet in length and in any case, two lines of tile will be installed. A minimum of 6 feet will be maintained between the center lines of the disposal field trenches and the average depth of. trench shall not exceed 36 inches. No part of the installation will be less than 100 feet from any private water supply, 25 feet from any stream, 20 feet from any dwelling or 10 feet from any property line. I further agree not to cover any portion of this installation until approved by the inspection officer, as provided below, and to incorporate any additional requirements th t e, attachecj tto the permit. Plot Plans must be submitted with application. 20x0 ac Ing bed faith 160 feet of lines in bed Bedhovder 5 feet o gravel and 1 foot o ruse stone. DATE 7/26/72 Signa ure of Applic I hereby issue the above permit for the Bo d of Healt of the Town of North Andover, Massachusetts. DATE Signature of Health Agent I have inspected the uncovered system indicated above and find everything done as describe . DATE � � ' 7Z- \ P Signature of n pecting Officer Percolation Test Garbage Grinder BOARD OF HEALTH TOWN OF NORTH ANDOVER, MASS. f`y SLP l .. 4- 1. NAME +v -rt T pr- DATE 7 f.3 - 2. ADDRESS ►'// $,` LOT N0. TEL. i�,/ 3. NO. OF BEDROOMS DEN YES NO 4. GARBAGE GRINDER YES NO �a i 5. SHOW DIMENSIONS OF HOUSE ld� z 6. SHOWS DISTANCES OF HOUSE TO ALL PROPERTY LINES 7. SHOW DIMENSIONS OF LOT 8. SHOW LOCATION AND SIZE OF SEPTIC TANK OR CESSPOOL g. NOTE LOCATION AND DISTANCE OF WELL FROM SEWERAGE SYSTEM 10. SHOW LOCATION OF BROOKS, STREAMS, DITCHES, LEDGE OUTCROP, ETC. 11. SHOW DISTANCE OF SEPTIC TANK OR CESSPOOL FROM HOUSE j I NOTE: LOCAL REGULATIONS SHOULD BE READ CAREFULLY. i t/ w BOARD OF HEALTH OF NORTH ANDOVER, MASSACHUSETTS SEWAGE DISPOSAL DATE 7-15-172 NAME OF APPLICANT J & V Realty - John J. Burke LOCATION Lot A Hillside Road Address of lot no. BUILDING: Dwelling X Other SYSTEM: New X Repair GENERAL DESCRIPTION OF LAND high SUBSOIL: Clay Gravel Sand PERCOLATION TEST minutes per inch. s - - - - - - - - - - - MINIMUM INSTALLATION RECOMMENDATIONS CONCRETE SEPTIC TANK 1 -n,. nn gallon capacity. LEACH FIELD 1h() lineal feet of drain pipe. Bed to be 20 x 40 with 160 feet lines in bed. Bed over 5 feet of gravel and 1 ft. er. stone. s William J. Dr s oll , Engine. Board of Healt