HomeMy WebLinkAboutMiscellaneous - 125 PEACH TREE LANE 4/30/2018 (12) - ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES
" A AMPERE 1. THIS SYSTEM IS GRID-INTERTIED VIA A
AC ALTERNATING CURRENT UL-LISTED POWER-CONDITIONING INVERTER.
BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS.
CONC CONCRETE 3. A NATIONALLY-RECOGNIZED TESTING
DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN
EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3.
(E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING
EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION,
FSB FIRE SET-BACK A SIGN WILL BE PROVIDED WARNING OF THE
GALV GALVANIZED HAZARDS PER ART. 690.17.
GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE
GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY
HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5.
I CURRENT 6. CIRCUITS OVER 250V.TO GROUND SHALL
Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B).
Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER
kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR
kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC
LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E).
MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN
(N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY
NEUT NEUTRAL UL LISTING.
NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE
OC ON CENTER UL-LISTED LOCATION PROVIDED BY THE
PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING
POI POINT OF INTERCONNECTION HARDWARE.
PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE
SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS.
S STAINLESS STEEL
STC STANDARD TESTING CONDITIONS
TYP TYPICAL
UPS UNINTERRUPTIBLE POWER SUPPLY
V VOLT
Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX
Voc VOLTAGE AT OPEN CIRCUIT
W WATT
3R NEMA 3R, RAINTIGHT PV1 COVER SHEET
PV2 SITE PLAN
PV3 STRUCTURAL VIEWS
PV4 UPLIFT CALCULATIONS
� " ''�� -. � � PV5 THREE LINE DIAGRAM
LICENSE GENERAL NOTES Cutsheets Attached
GEN #168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION .
ELEC 1136 MR OF THE MA STATE BUILDING CODE.
2. ALL ELECTRICAL WORK SHALL COMPLY WITH
THE 2014 NATIONAL ELECTRIC CODE INCLUDING
MASSACHUSETTS AMENDMENTS.
MODULE GROUNDING METHOD: ZEP SOLAR
AHJ: North Andover
REV BY DATE COMMENTS
REV A NAME DATE COMMENTS
UTILITY: National Grid USA (Massachusetts Electric)
* * * *
CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER-- PREMISE OWNER: DESCRIPTION: DESIGN:
JB-0183253 00
BENEFIT OF ANYONE EXCEPT
CONTAINED SHALL NOT E USED FOR THE PT SOLARCITY INC., MOUNTING SYSTEM: TENENBAUM, BETSY TENENBAUM RESIDENCE Colleen Collins `SolarC�ty.
�•.,�
NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 125 PEACHTREE LN LOT 13 10.2 KW PV ARRAY A.,
PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES NORTH ANDOVER MA 01845
ORGANIZATION, EXCEPT IN CONNECTION WITH , 24 St. Martin Drive, Building 2, Unit 11
THE SALE AND USE OF THE RESPECTIVE (40) TRINA SOLAR # TSM-255PDO5.18
Marlborough, MA 01752
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE L• (650)638-1028 R (650)638-1029
PERMISSION of SOLARCITY INC. SOLAREDGE SE1000OA-USOOOSNR2 (978) 314-7297 COVER SHEET PV 1 12/22/2015 (888)—SOL-CITY(765-2489) www.solarcity.com
t.
PITCH: 40 ARRAY PITCH:40
MPi AZIMUTH: 161 ARRAY AZIMUTH: 161
MATERIAL: Comp Shingle STORY: 2 Stories
PITCH: 40 ARRAY PITCH:40
MP2 AZIMUTH:-161 ARRAY AZIMUTH: 161
MATERIAL: Comp Shingle STORY: 2 Stories
o
J
C
J
N
(E)DRIVEWAY
L _
V
O
N
L0
N
C e
LEGEND
Front Of House O (E) UTILITY METER & WARNING LABEL
q Inv INVERTER W/ INTEGRATED DC DISCO
& WARNING LABELS
FD
t> DC DISCONNECT & WARNING LABELS
�> ® AC DISCONNECT & WARNING LABELS
4
DC JUNCTION/COMBINER BOX & LABELS
B DISTRIBUTION PANEL & LABELS
Lc LOAD CENTER & WARNING LABELS
ACD�,I O DEDICATED PV SYSTEM METER
I- J
I ' IB
'"` Q STANDOFF LOCATIONS
Inv O /' """ CONDUIT RUN ON EXTERIOR
ACS JgSQ@1 WIL IAI CONDUIT RUN ON INTERIOR
- TOMAN GATE/FENCE
s3 TRUIJTIIRAL �,, 0 HEAT PRODUCING VENTS ARE RED
No.51554 re `! INTERIOR EQUIPMENT IS DASHED
G�ST f4
' �{SNAL SITE PLAN
3/2015 Scale: 3/32"
Digitally signed by Jason Toman 01' 10' 21'
Date: 2015.12.23 00:32:52-07'00' 3
PREMISE OWNER: DESCRIPTION: DESIGN;
CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER J[3-0183253 OO TENENBAUM, BETSY TENENBAUM RESIDENCE Colleen Collins �pl.
CONTAINED SHALL NOT BE USED FOR THE SolarC�tyBENEFIT OF ANYONEEXCEPT SOLARCITY INC., MWNTING SYSTEM: �NOR SHALL IT.BE DISCLOSED IN WHOLE OR IN Com Mount T e C 125 PEACHTREE LN LOT 13 10.2 KW PV ARRAY 0
PART IZ OTHERS OUTSIDE THE RECIPIENTS MODULES NORTH ANDOVER MA 01845
„
ORGANIZATION, EXCEPT IN CONNECTION WITH r
THE SALE AND USE OF THE RESPECTIVE (40) TRINA SOLAR # TSM-255PDO5.18 St. Martin Drive, Building 2,Unit 11
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REN DATE Morlborough, MA 01752
PERMISSION OF SOLARCITY INC. INVERTER: 978 314-7297 PV 2 12/22/2015 888.- (�)638-1028 F. (650)638-1029
SOLAREDGE SE1000OA—USOOOSNR2 SITE PLAN ( )_SOL_Cm(765-2489) www.solarcit.com