Loading...
HomeMy WebLinkAboutMiscellaneous - 125 PEACH TREE LANE 4/30/2018 (12) - ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES " A AMPERE 1. THIS SYSTEM IS GRID-INTERTIED VIA A AC ALTERNATING CURRENT UL-LISTED POWER-CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY-RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET-BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. I CURRENT 6. CIRCUITS OVER 250V.TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL-LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS � " ''�� -. � � PV5 THREE LINE DIAGRAM LICENSE GENERAL NOTES Cutsheets Attached GEN #168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION . ELEC 1136 MR OF THE MA STATE BUILDING CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: ZEP SOLAR AHJ: North Andover REV BY DATE COMMENTS REV A NAME DATE COMMENTS UTILITY: National Grid USA (Massachusetts Electric) * * * * CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER-- PREMISE OWNER: DESCRIPTION: DESIGN: JB-0183253 00 BENEFIT OF ANYONE EXCEPT CONTAINED SHALL NOT E USED FOR THE PT SOLARCITY INC., MOUNTING SYSTEM: TENENBAUM, BETSY TENENBAUM RESIDENCE Colleen Collins `SolarC�ty. �•.,� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 125 PEACHTREE LN LOT 13 10.2 KW PV ARRAY A., PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH , 24 St. Martin Drive, Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (40) TRINA SOLAR # TSM-255PDO5.18 Marlborough, MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE L• (650)638-1028 R (650)638-1029 PERMISSION of SOLARCITY INC. SOLAREDGE SE1000OA-USOOOSNR2 (978) 314-7297 COVER SHEET PV 1 12/22/2015 (888)—SOL-CITY(765-2489) www.solarcity.com t. PITCH: 40 ARRAY PITCH:40 MPi AZIMUTH: 161 ARRAY AZIMUTH: 161 MATERIAL: Comp Shingle STORY: 2 Stories PITCH: 40 ARRAY PITCH:40 MP2 AZIMUTH:-161 ARRAY AZIMUTH: 161 MATERIAL: Comp Shingle STORY: 2 Stories o J C J N (E)DRIVEWAY L _ V O N L0 N C e LEGEND Front Of House O (E) UTILITY METER & WARNING LABEL q Inv INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS FD t> DC DISCONNECT & WARNING LABELS �> ® AC DISCONNECT & WARNING LABELS 4 DC JUNCTION/COMBINER BOX & LABELS B DISTRIBUTION PANEL & LABELS Lc LOAD CENTER & WARNING LABELS ACD�,I O DEDICATED PV SYSTEM METER I- J I ' IB '"` Q STANDOFF LOCATIONS Inv O /' """ CONDUIT RUN ON EXTERIOR ACS JgSQ@1 WIL IAI CONDUIT RUN ON INTERIOR - TOMAN GATE/FENCE s3 TRUIJTIIRAL �,, 0 HEAT PRODUCING VENTS ARE RED No.51554 re `! INTERIOR EQUIPMENT IS DASHED G�ST f4 ' �{SNAL SITE PLAN 3/2015 Scale: 3/32" Digitally signed by Jason Toman 01' 10' 21' Date: 2015.12.23 00:32:52-07'00' 3 PREMISE OWNER: DESCRIPTION: DESIGN; CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER J[3-0183253 OO TENENBAUM, BETSY TENENBAUM RESIDENCE Colleen Collins �pl. CONTAINED SHALL NOT BE USED FOR THE SolarC�tyBENEFIT OF ANYONEEXCEPT SOLARCITY INC., MWNTING SYSTEM: �NOR SHALL IT.BE DISCLOSED IN WHOLE OR IN Com Mount T e C 125 PEACHTREE LN LOT 13 10.2 KW PV ARRAY 0 PART IZ OTHERS OUTSIDE THE RECIPIENTS MODULES NORTH ANDOVER MA 01845 „ ORGANIZATION, EXCEPT IN CONNECTION WITH r THE SALE AND USE OF THE RESPECTIVE (40) TRINA SOLAR # TSM-255PDO5.18 St. Martin Drive, Building 2,Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REN DATE Morlborough, MA 01752 PERMISSION OF SOLARCITY INC. INVERTER: 978 314-7297 PV 2 12/22/2015 888.- (�)638-1028 F. (650)638-1029 SOLAREDGE SE1000OA—USOOOSNR2 SITE PLAN ( )_SOL_Cm(765-2489) www.solarcit.com