Loading...
HomeMy WebLinkAboutMiscellaneous - 1423 SALEM STREET 4/30/2018 (73) �r CHECKLIST FOR NORTH ANDOVER SEPTIC SYSTEM PLANS N&M Job 1770/ 59 The following is a checklist that incorporates all Title 5 and local regulations for septic plans. Name of Applicant: 10'74?eZ P /G t- Name of Designer: Plan Date: /A n a .Z-Revision Date: Z- Date of Review: ® _ Property Address: i¢Z? 7` Map: /06 Lot: BOH Reviewer: �/` /140 Type of Plan(new orpgra . Number of Bedrooms in Assessor's Records: gpd)Garbage Disposal Allowed: General Information: N.A.=North Andover Septic Regulations Other numbers refer to Title 5 �OK problem N/A Street number and map/lot-220(4)(u) Maximum scale of 1 "=40'for plot plan-220(4) ��-- Maximum scale of 1 "=20'for profile and component details-220(4) Legal boundaries of the facility being served-220(4)(a) i/ Names of abutters from recent tax map- NA 8.02j Number of bedrooms,design.calcs.,-NA 8.02i Name&address of record owner&applicant- NA 8.02k Name&address of designer-NA 8.021 Holder and location of all easements-220(4)(b) Date plan drawn&any revision date- NA 8.02m All dwellings and buildings,existing and proposed--220(4)(c) Location of all existing or proposed impervious areas-220(4)(d) All distances on site plan-NA 8.03a-c Elevation of proposed driveway-NA 8.02t Location and elevation of foundation drain-NA 8.02y Location and dimensions of the system incl.reserve(new const.)-220(4)(e) Limits of excavation of leach area on site plan-NA 8.02z Locus plan-220(4)(t) (Not to scale) North arrow-220(4)(g) Existing and proposed contours-220(4)(g). Locations and logs of deep holes-220(4)(h) Locations and logs of percolation tests-220(4)(i) L____ Date(s)of soil testing-220(4)(h)&(i) Existing grade elevation of each deep hole-220(4)(h) Elevation of percolation tests-N.A. 8.02n _ Name of approving authority representative-220(4)(h)&(i) Name of soil evaluator-220(4)0) Soil logs and perc test logs match BOH records Locations of waterlines,drains,and subsurface utilities-220(4)(m) SCC Observed and adjusted g.w.elevation in the vicinity of the system-220(4)(n) Complete profile of the system to scale-220(4)(o),NA 8.02c Cross section of leaching facility-NA 8.02w (Not to scale) Location of benchmark(s)within 50-75 feet of facility-220(4)(q) CN Note listing all variance requests with proper citations-220(4)(p) Local upgrade approval request form submitted-403(1) Original R.S./P.E.stamp,signature&date-220(1)&(2) If P.E.,discipline specified within stamp. MGL C. 112 s. 81M sfc. supplies(w/in 400'),pub. wells(w/in 250'),pvt.wells(w/in 150')-220(4)( Location of watercourses,wetlands,wells,etc.Win 150'of system-NA 8.02r d Wetland disclaimer-NA 8.02s RLS plan reference&certification required(prop line setbacks)-220(3) Use approvals/standards checked for I/A system-DEP docs., 2 Perc rate>30 MPI-not allowed for.new,LUA for u ade- 245(1)&('3) P e r c rate>60 MPI-must use modified tight tank or UA technology-245(4) Proposed system qualifies as"shared" system-002(definitions) Flow is over 2,000 gpd-No R.S.allowed-220(1) .�' Design flow was set in accordance with code-203 Existing system location and note on proper abandonment-354 Leaching facility at least 1' above Base Flood elevation-NA 9.05 f/ All piping Sch 40 minimum-NA 10.01 Basement floor minimum F above groundwater elevation-NA 5.04 �--` Foundation drain present with elevation-NA 8.02y On-site Soil and Groundwater Review OK Problem N/A �— Proper deep observation hole logs on plan-220(4)(h) All deep holes and peres shown,including aborted tests-NA 8.02n Soil evaluation forms submitted within 60 days of field work-018(2) Proper percolation test log-220(4)(i) Ample deep observation holes in primary disposal area(minimum 2) - 102(2) Ample deep observation holes in secondary disposal area(minimum 2)- 102(2) Ample perc testing(one in each disposal area,3 in prim.>2,000 gpd)- 104(4) �--'~ Deep hole testing conducted within two years-NA 7.05 Hole Identification Numbers: ground elevation el. acceptable soil el. Leach facilitv invert el. J ground water el. `s refusal el. bottom of leach facility el. thickness of acceptable soil before&after soil R&R separation to groundwater a/ separation to refusal soil classy perc rate �%- loading rate septic tank below g.w.table (yes or no) pump tank below g.w.table (yes or no) I.f in fill 4/ -255(l) Setback Distances(Given in feet) 15.21 1 YES NO Is the lot in the Lake Cochiewick Watershed? NA 6.00&5.02 OK Problem N/A Septic Tank Leach Facility ,t"✓. Property line 10 10 v Cellar wall 10 20 2 I�