Loading...
HomeMy WebLinkAboutMiscellaneous - 1423 SALEM STREET 4/30/2018 (124) INSPECTION CHECKLIST FOR SEPTIC SYSTEMS Yes NO Initis s A. Bottom of Bed 1. Excavation to proper depth 2. With trenches,sides of excavation are beneath B horizon 3. Edge of excavation specified distance from foundation,etc. y' Comments: I B. Retaining Wall j 1. Wall height and width as specified 2. Waterproofed 3. Wall minimum 10'to leaching facility 4. Wall meets specifications of plan Comments: C. Building Sewer ,. C--'6�s fi !) t- �� 1. Pipe diameter minimum 4" U MP 2. Schedule 40 pipe 3. Watertight joints 4. Inlet to tank cemented 5. Slope minimum 0.01 or 1/8"per foot minimum 6. Pipe properly set on compact firm base 7. Pipe Iaid on continuous grade in straight line 8. C:leanouts precede all change in alignment and grade 9. Manholes at any 90°change 10. 10'minimum offset to water line Comments: D. Septic Tank 1. Level 2. 1,500 gal minimum 3. Gas baffle present on outlet 4. Manhole to grade 5. Manholes over center and each tee 6. 3-20"manholes 7. Inlpt tee minimum 12"under invert 8. Outlet tee minimum 14"under invert 9. Outlet line cemented 10. Air space 3"above tees 11. 2''-3"drop from inlet to outlet 12. Pipe set 13. Compact base with 6"of'/4"crushed stone under tank 14. Tank is watertight Comments: