Loading...
HomeMy WebLinkAboutMiscellaneous - 160 CHRISTIAN WAY 4/30/2018 (2) 160 Christian Way "�'� May-19-00 10: 55A Paul D. Turbide, PE/PLS 978-465-0313 P-03 May 19, 2000 Sandra Star: North Andover Board of Health Administrator Office of Community Development and Services 120 Main Street North Andover,MA 01845 RE: Title V third review for Christian Way Extension, Lot 4 Dear Sandra, I have reviewed the revised design plan(which revises the number of bedrooms from 4 to 5)for the above project with revision date of 01 May 2000. Apparently the house has been built and the septic system installed as per plans with revision date of October 21, 1999. The proposal is to increase the width of the system from 24 feet to 26 feet by adding an additional 1-foot of stone to each edge of the system. An additional I-foot of septic sand is proposed to be placed on both sides of the leaching bed to ensure that top and subsoil are removed and replaced with sand in the 5 foot area around the system. I find that this revision adequately addresses the regulations. I would like to make the following observation. The approved design plan with revision date of October 21, 1999 was designed for 4 bedrooms yet had a proposed leaching bed that was adequate for 547 GPD(3 GPD short of being adequate for 5 bedrooms). To make up for this shortage of 3 GPD the proposal is to disturb the system and lawn to add more area to the leaching bed. The original design had an LTAR of 0.6 gaVSF because TH 98-4-01 had a receiving layer texture of sandy loam which is a Class II soil. If the receiving layer texture of TH 98-04-01 had been a loamy sand, then the soil would have been a Class I soil in which case the LTAR would have been 0.74 gaVSF and the existing system would have been adequate for 674 GPD or 6 bedrooms. I note that TP 984-02 had a receiving layer of loamy sand, and that the older test pits done in 1987 and 1993 would indicate a receiving layer of sand or loamy sand. Thus the existing leaching bed is almost adequate for 5 bedrooms because the existing leaching bed capacity for Class II soils is lacking only 3 GPD, and the soils are almost Class 1 soils. However, to follow the letter of the law, the existing system is not PORT adequate for 5 bedrooms and therefore I believe the proposed revised system will It I adequately address the regulations for 5 bedrooms. ENGINEERINGIf you have any questions or comments please feel free to contact us. Civil Engineers& Land Surveyors Sincerely) ,-e Harris t,M Ne wburyportMA 01951! C./� (978)465-8594 Carlton A. Brown,PEIPLS r ( t E - s Atlantic Engineering & Survey Consultants, Inc. 97 Tenney Street Suite 3 Gcorptown,MA 01833 (978)352-7870 — Fax(978)352-9940 June 15, 2000 Mrs. Sandra Starr North Andover Board of Health 27 Charles Street Noah Andover, Ma. RE: Lot 4 Septic System Revision Brook Farm Dear Sandy: The existing septic system located at the above referenced site has been field inspected by our office today. It has been determined that the existing system 'as previously installed meets the requirements for a five bedroom dwelling. Therefore it is my recommendation that no further action needs to be taken. If you have any questions please feel free to call. Sincerely,, j Thomas C. Mannetta, Jr. Director of Engineering cc:Mangano Development Corp. T0 'd Ob66ZS£80S ONIa33NION3 '3I1Nti11V Wd Lb: £0 00-ST-Nnr wORYH Town ","North Andover Community Development & Services William J. Scott ~ ...:. » • 27 Charles Street Director North Andover, Massachusetts 01845 (978)688-9531 CHU Fax 978-688-9542 Board of July 18,2000 Appeals (978)688-9541 Atlantic Engineering and Survey consultants,Inc. Building Thomas C. Mannetta,Jr. Department 97 Tenney Street, Suite 5 (978)688-9545 Georgetown,MA 01833 Conservation Dear Mr. Mannetta, Department This letter is in regards to Lot 4 Brook Farm aka 160 Christian Way. I am following (978)688-9530Y� g up my conversation that was held with your office after receiving your letter regarding the septic system at this location,dated June 15,2000. (See attached) If you recall,I requested an Health Department as-built of the septic system be submitted to the Health Department. To date this office has (978)688-954o not received the submittal. It is imperative that we receive the as-built so that this file can be closed. As it Public Health presently stands,the file has approved plans for the expansion of this septic system to Nurse accommodate an 1 I-room home. Your letter indicates that the existing system in ground is (978)688-9543 larger than initially thought and it could handle the increased flow as is,therefore,there would be no work needed to expand this system. These determinations must be shown on an as- Planning built so that we may verify your findings. Without the documentation requested,the Health Department Department is still not clear on the exact size of the septic absorption area. (978)688-9535 Please submit the required information to this office as soon as possible. Thank you for your cooperation in this matter. Sincer ;,..--- san Ford, S Health Inspector Cc: Sandra Starr,Health Director file NORTq Town Of North Andover Of �ti '�•D °pWilliam J. Scott Community Development & Services Director . 27 Charles Street ----- •'''' (978) 688-9531 North Andover, Massachusetts 01845 Sg.ICHUSt Fax 978-688-9542 May 19, 2000 Board of Appeals Atlantic Engineering (978) 688-9541 Tom Marietta 97 Tenney Street Ste. 5 Building Georgetown, MA 01833 Department (978) 688-9545 Re: 160 (Lot 4) Christian Way Conservation Dear Mr. Manetta: Department (978) 688-9530 This letter is to notify you that the proposed plan for the increase of the septic system at the above-referenced site has been approved. This will allow a Health maximum of eleven(11) rooms in the dwelling. Department (978) 688-9540 please call the office at 978-688-9540 if you have any questions. Public Health Nurse Sincerely, (978)688-9543 Planning Department (978) 688-9535 Sandra Starr, R.S., C.H.O. Health Director Cc: Mangano Development Corp. File FORM U - .LOT RELEASE FORM IySTRUC T IONS: This form is used to verify that all necessary approvals/permits from' Boards and Departments having jurisdiction have been obtained. This does not re!ieve the applicant and/er landowner from compliance ��vith any applicable or requirements. � AFFL1CA,�aT FILLS OUT THIS SEC -TIC - A�PucANT A � �1 ►"\t���� PHONE O vU LCCATICN: Assesses M2.0 dumber P.aRCE_� SUEDIVISION LOT (S) STRE=T ���-�`r `�v S T. NUMEER -v OFFICIAL USE ONLY}` RECOMMENDATIONS OF TOWN AGENTS: F-1 NI X41 IR AS e- M-eNj-t " CONSERVATION ADMINISTRATOR DATE APPROVED DATE REJECTED COMMENTS TOWN PLANNER DATE APPROVED DATE REJECTED COMMENTS FOOD INSPECTOR-HEALTH DATE APPROVED DATE REJECTED gEPfi IN PECTOR-HEALTH DATE APPROVED �c? DATE RcJECTED- 3 s 7f? s;z COMMENTS a � 2 � r Co' PUBLIC 'NORKS - S�NERMIATCo NECTIONS DRIVE'NAY PERMIT FIRE DEPARTMENT RECEIVED EY EUILGiNG iNSP`=C T CR DATE Revi<_e-� 9°'im Porier Residence Finish Basement - -- - 14'-0" - � r ? � i WA I Concrete Slab 10'-0" I -- - 33'-0'' — -- - � 1 Window 6 FT Slide Door Window j H2O Heater, Play Room j 1 - - - - - - - Garage 2 -0Direct Vent Hot Air Furnace 7 GLosgT Un-Finished Utility Area Up H2O Bi-Fold Access l Bi-Fold Panell Closet t _JEL Storage _— 8'-0" � Drawing By: Miles Above Design-Build 25 Feb 2000 SEPTIC PLAN SUBMITTAL FORM LOCATION: J (e)O Ch r t5*gr> U-)qy LO+ y Not+V\ Anclux� NEW PLANS: YES $125.00/Plan REVISED PLANS: � `YESi $ 60.00/Plan SITE EVALUATION FORMS INCLUDED: YES% NO J DATE: 1�`oo DESIGN ENGINEER: DATE TO CONSULTANT: If you want your plans expedited, ase submit three plans and included a - stamped envelope with the corre amount of postage to mail plans to Port Engineering. When the submission i 11 in place, route to the Health Secretary. January 13, 1999 Sandra Starr North Andover Board of Health Administrator Office of Community Development and Services 120 Main Street North Andover, MA 01845 RE: Title V second review for Christian Way Extension, Lot 4 Dear Sandra, I have reviewed the revised design plan for the above project with revision date of 11 December 1998. I find all my original concerns have been addressed except for the following. As per 310 CMR 15.221(2)there must be a 6" stone base beneath the d-box and the septic tank. The plans correctly have added"310 CMR 15.221(2)" and have added a six inch base beneath the d-box and septic tank on the plans, but they still call for"gravel" instead of"stone". The word"gravel' should be deleted and the word "stone" put in its place. (If this minor change is made, I do not need to review this plan again.) If you have any questions or comments please feel free to contact us. Sincerely Carlton A. Brown,PE/PLS PORTIti ENGINEERING Civil Engineers& Land Surveyors One Harris Street Newburyport,MA 01950 (978)465-8594 Atlantic Engineering & LETTER OF TRANSMITTAL Survey Consultants, Inc. Land Surveyors- Civil Engineers - Planners 97 Tenney Street — Suite 5 Georgetown, MA 01833 (978)352-7870 — Fax(978)352-9940 Transmittal To: N. Andover Board of Health Job No: A0004-10 Date: 5/3/00 Ref: Lot 4 Christian Way Attention: WE ARE SENDING YOU X Attached Under Separate Cover Reports Letter Original Plans Forms X Prints Specifications Copies Date Description 3 5/1/00 Revised Plan of Proposed Sewage System(5 Bedroom) THESE ARE TRANSMITTED as checked below: For your use Approved as submitted Resubmit copies for approval X For Approval Approved as noted Submit As Requested Returned for corrections Return corrected prints For Review and comment Other Initial C:\Win2000 Correspondence\Brook Farm\TR Lot 4 Brook BOH 050300.wpd FORM U - LOT RELEASE FORM I�ISTRUCTICNS: This form is used to verify that all nec-ssary approvals/permits from Ecards and Departments having jurisdiction have been obtained. This does not relieve the applicant and/er landowner from compliance with any applicable or requirements. AF1✓LICANT FIL_S OUT TH1S SFCTiON�""**�'`�'`�`�***-`���� � Mr _ ArFL!CAI`a T A-�L � \I LCIS PHONE LCCA T 10 N: ass2sz&s map dumber 1 C� l� F,4RCE_� SUSDIVISION LOT (S) STRL=T �1�R-�-S �J ST. NUMEER 1 (v OFFICIAL USE ONLY RECOMMENDATIONS OF TOWN AGENTS: i N I lSr` IR ws M-e NJ cCNSERVATIGN ADMINISTRATOR DATE APPROVED DATE REJECTED COMMENTS TOWN PLANNER DATE APPROVED. DATE REJECTED COMMENTS FOOD INSPECTOR-HEALTH DATE APPROVED / DATE REJECTED cEFT IN PECTOR-HEALTH DATE APPROVED DATE REJECTED 3TC COMMENTS o z �"� '`^� „" S bx c_o�e_ C�'U'L 7 ►"ovw� S es>L, ;t zvov�eZ +-•L/G��C' ��oae� PUELIC WORKS -SENERMIATE. CONNECTIONS DRIVE'NAY PERP411T FIFE DEPAiT'IENT F,E'.EtVE, EY EUILr1NG iNSPECTCR DATE FORM U - LOT RELEASE FORM INS,T»UCTICNS: This form is used to verity that all necessary 2perovals/permits from Boards and Departments having jurisdiction have been obtained. This does not relieve the applicant and/or landowner from compliance with any applicable or requirements. `*AFFLICANT FiL!S OUT THIS APPLICANT_ T w% M#,j%6At%,a PHCNE LOCATION: Map Num, ber / PARCEL SUEDIVISION 13QAlck FAtZ M LSf LOT (S) STREET 0,ha 4sAn Mtgy E x-f S T. NUMEER t* OFriCIAL USE ONLY * R COMMEND T 10 S OF TOWN AGENTS: .DecK C NSERVATION ADMINISTRATOR DATE APPROVED 1 C,I lnj� i L DATE REJECTED COMMENTS �t�L�t t e TOWN PLANNER DATE APPROVED DATE REJECTED COMMENTS FOOD INS ECTOR-_EALTH DATE APPROVED DATE REJECTED SE..'TIC INSPECTOR-HEALTH DATE APPROVED DATE REJECTED COMMENTS PUELIC WORKS -ScNER/WATER CONNECTIONS DRIVEWAY PERPAIT FIRE DEPAR7MEN7 RECE!VE, EY EUILDitlG iidSPECTCR DA I Revised ctc im V 182.77' 3$oA-21 �� aW A-19 A-22 A-20 � A-18 2S. 6� A-23 �R �\ A-17 A-24 � i LOT 4 \ 80,344 S.F. �G. A-16 !Q A-25 �\ _A-15 I I PROPOSED �\ I I 12'x21' DRAINAGE DECK ��� F-ASEMENT A-26 • p 108122 ip I io 11 I p,N O 1 9 i J 2 I I -n I � � O I 149.05 F A-29 m I PROPOSED DECK ADDED TO PLAN JAN. PLAN OF LAND A 7LANTIC ENGINEERING & IN I SURVEY CONSUL TANTS INC.