Loading...
HomeMy WebLinkAboutMiscellaneous - 1600 OSGOOD STREET 4/30/2018 (67) 1600 Osgood Street Building#37 i CERTIFICATE OF USE & OCCUPANCY TOWN OF NORTH ANDOVER Date: November 4, 2004 THIS CERTIFIES THAT THE BUILDING LOCATED ON 1600 Osgood Street—Building Regarding: Court Concepts, Inc. MAY BE OCCUPIED AS Batting Cage—Less than 50 people IN ACCORDANCE WITH THE PROVISIONS OF THE MASSACHUSETTS STATE BUILDING CODE AND SUCH OTHER REGULATIONS AS MAY APPLY. Certificate Issued to: Oza Properties, Inc This Certificated of Occupancy Is issued pursuant to the attached CODE SUMMARY 3 Dundee Park 780 CMR Chapter 34,prepared by Jay A.Leradi of the Sullivan Code Group(R.W. Sullivan Engineering), Andover Ma 01810 Dated August 24,2004 VL � Building Inspector Code Consulting Fire Protection Engineering CODE SUM MARY if Sullivan Code Group 780 CMR CHAPTER 34 REPORT R.W.Sullivan Engineering Union Wharf Condominiums 343 Commercial St.,Suite 302 1600 Osgood Street (617)523827chusetts 021og FAX 523-8016 22 Building #37 www.rwsullivan.com North Andover, Massachusetts Date: August 24, 2004 Prepared By: Jay A. lerardi Reviewed By: A. Vernon Woodworth, AIA Introduction Building #37 is an existing single story steel framed building set upon a concrete slab at 1600 Osgood Street in North Andover, Massachusetts. The building was previously utilized for manmade crystal production (Use Group F-2 manufacturing of noncombustible materials)as well as laboratory and offices spaces(Use Group B business). The building contains a mezzanine level used for records storage (Use Group S-1 moderate-hazard storage) and also contains electrical and mechanical equipment including two 2,500 kVA dry-type transformers (Use Group S-2 low-hazard storage occupancies). Based on observations made during our August 20, 2004 walkthrough the building appears to be Type 2C noncombustible unprotected construction. It is our understanding that the proposed work involves tenant alterations to the building and a change in use that will include a showroom for flooring(Use Group M mercantile)as well-as batting cages (Use Group A-3 if used by 50 or more people, Use Group B if used by < 50 people). It is also our understanding that the mezzanine level will not be made. available to the tenant,and therefore,the mezzanine level is not included within the scope of this report.'�The existing mezzanine occupies over 1/3 of the area below(approximately 42%) which exceeds the area limitation for mezzanines (505.3). However, the existing mezzanine is allowed to occupy up to 2/3 the area below for Type 2 buildings containing special industrial occupancies. If the mezzanine were made available to the tenant, the change in use would require this level to be considered a second story. The existing mezzanine only has one means of egress which is permitted for Storage Use Groups with an occupant load below 30 and a maximum travel distance of 100 ft(Table 1017.2). The existing conditions for the existing mezzanine are consistent with 780 Section 102.5.2: "any existing building ...shall be presumed to meet the provisions of the applicable laws, codes, rules or regulations ... in effect at the time such building was constructed or altered and shall be allowed to continue to be occupied pursuant to ` Chapter 34 Report 1600 Osgood Street—Building#37 North Andover,Massachusetts August 24,2004 Page 2 its use and occupancy provided that the building ... shall be maintained in accordance with 780 CMR 103[in a safe, operable, and sanitary condition]." However, a change in use of the mezzanine area could potentially result in a situation requiring a second means of egress to be installed. We would recommend that the existing -mezzanine continue its existing use (storage) and occupancy (normally unoccupied). Due to the large amount-ofar@a required to accommodate a single person per batting cage, it is likely that the occupant:load will be less than 50 people in the batting cage area. ` This 50 person limit is significant in terms of the particular requirements for repairs...or alterations to existing buildings. We would recommend that the tenant be made aware of and comply with this limitation on occupancy in the batting cage area. Massachusetts State Building Code (780 CMR) Requirements Repairs and alterations to this existing building must comply with the requirements of 780 CMR Chapter 34. The building previously was used primarily for manmade crystal production which is Use Group r-2 with a Hazard Index of 3. The proposed change in use by the tenant to a showroom (Use,Group M with a Hazard Index of 3) and batting cages (Use Group A-3 with a Hazard Index of 4 if used by 50 or more people, Use Group B with a Hazard Index of 2 if used by<50 people). The change in use group results in a change in ,Hazard.lndex of one.or less and, therefore,the repairs and alterations to this building are subject to the requirements of 780 CMR 3404.0 and 3408.0 (per 3404.1). Our code summary describes the applicable requirements of 780 CMR 3400.0 and is based on the following documents provided by Ozzy Propedlies: • Building No. 37 Partial Floor Plan Equipment Layout(drawing#FPV-106275 dated p .M�. 02/23/02). • Building No. 37 Partial Floor Plan Equipment Layout (drawing #FPV-106275-A dated 04/22/04). • Building Elevations & Misc. Details (drawing #222-81-302, modified 06/15/01). • Building 37 Addition Truck Dock Steel Plan and Details (drawing #FPV108821 modified 01/17/01). 3404.3 New Building Systems All new building systems are required to comply with the code requirements for new construction to the fullest extent practical. However, individual components of an existing building system can be replaced or repaired without requiring the entire system to comply with the code requirements for new construction. Chapter 34 Report 1600 Osgood Street—Building#37 North Andover,Massachusetts August 24,2004 Page 3 Any new interior finish must comply with the following: New Interior Finish Requirements 780 CMR Table 803.4 Requirement Batting Showroom Building Area Cages Eat Stair Class I Class I Exit Access Corridors Class II Class II Rooms&Enclosed Spaces Class III I Class II for ceilin a),Class III for walls (a)—. III permitted merrantile occupancy is 3,000 sf or less gross floor area and on the street level. 3404.5 Number of Means of Egress All floors must be provided with a minimum number of exits as required by the code for new construction. The required number of exits is based on the occupant load of each floor area. It is not possible to provide an accurate occupant load calculation or make a determination if the egress is adequate at this time because the space has not been, partitioned into the designated showroom and batting cage areas. Floor plans indicating the designated showroom and batting cage areas are required in orderto provide a more accurate occupant load calculation as well as to determine if adequate egress is provided. Based on the limited information available at this time, the entire space will be considered for each individual occupancy type in order to make preliminary calculations of occupant load. The occupant load calculations are based on either gross floor area or net floor area, depending upon the specific occupancy type. The total gross floor area is 14,171 sf and the total net floor area is approximately 12,886 sf. Occupancy FloorArea s /Occu pant Floor Area Occupant Load Mercantile 30 gross 14,171 sf 473 Business 100 gross 14,171 sf 142 Unconcentrated Assembly 15 net 12,886 sf 859 The existing building contains 3 exits which can accommodate an occupant load of up to 1,000 (780 CMR Table 1010.2). 3404.6 Capacity of Exits All floors must comply with the code requirements for new construction with regard to exit capacity (780 CMR Section 1009.0). Again, since the occupant load cannot be calculated at this time it is not possible to address this specific requirement. However, the following general guidance can be provided. The egress width per occupant in a sprinklered building Chapter 34 Report 1600 Osgood Street—Building#37 North Andover,Massachusetts August 24, 2004 Air Page 4 containing Use Groups B and M is 0.2 inches per person for stairways and 0.15 inches per person for doors, ramps, and corridors (780 CMR Table 1009.2). These values are also subject to the following minimum dimensions: Egress Component 50 occupants or less Stairways 36" 1014.3 ex 1 Doors 32" (1014.8.1(3)) Exit access corridors 36" 1011.3 2 3404.7 t Signs All exits and exit access routes must be provided with exit signs in accordance with the code requirements for new construction (780 CMR Section 1023.0). 3404.8ress Li htin All exits and exit access routes must be provided with egress lighting in accordance with the code requirements for new construction (780 CMR Section 1024.0). 3404.9 Height and Area Limitations Since the proposed work will include a change in use,the height and area of the building is required to comply with the code requirements for new construction. The following tables show the building does meet the height and area limitations for this existing construction Type 2C separated mixed use building containing Use Groups B and M: eight and Area Limitations Code Reference Use Group BIM Height Area Table 503 2 Stories(30') 9,600 Section 504.2 +1 Story(20') Sprinkler Height Increase Section 506.2 Street Frontage Increase Section 506.3 + 19,200 ft Sprinkler Area Increase Section 506.4 Multistory Area Decrease(N/A) Total Allowed 3 Stories(50') 28,800 ff Actual Size Height and Area 1 Story(35') 14,171 Chapter 34 Report 1600 Osgood Street—Building#37 North Andover,Massachusetts August 24,2004 Page 5 Sepamted4ibmd-Use: The B and M Use Groups will require a 2 hour rated fire separation per 780 CMR Table 313.1.2. 3404.12 Fire Protection Systems The following fire protection systems, are required to be upgraded or, provided in accordance with 780 CMR Chapter 9 in the substantially altered or renovated areas over 12,000 ft2: Sprinkler System (780 CMR 904.2) Fire Protective Signaling System (780 CMR 918.5) • - Fire Extinguishers (780 CMR 920.2(1)) A substantial alteration is defined as work, which is major in scope and expenditure when compared to the work and expenditure required for the installation of a fire protection system (780 CMR Section 3401.0). The existing ceiling level sprinkler system was hydraulically calculated to deliver 0.30 gpm/sf over a 2,500 sf design area (corresponds to Extra Hazard Group 1 per NFPA 13) to flow 1429.40 gpm at 61.70 psi residual pressure at the base of the riser. The ceiling level sprinklers have a maximum coverage area of 100 sf. The existing sprinklers provided underneath the mezzanine area were designed by the pipe schedule method for Ordinary Hazard with a maximum sprinkler spacing of 130 sf. This information was obtained from sprinkler design documents contained in the storage cabinet for replacement sprinkler heads at the sprinkler riser. 3404.13 Enclosure of Stairways The existing open stairway to the mezzanine level is not required to be enclosed per 780 CMR 713.3 exception 4(exempts floor openings between a mezzanine and the floor below from being enclosed by a shaft). 3404.18 Accessibility for Persons with Disabilities Alterations to public areas of the building must comply with the requirements of the Massachusetts Architectural Access Board Regulations (521 CMR). For existing building alterations the requirements of 521 CMR are based on the cost of the proposed work: A. If the cost of the proposed work is less than$100,000,only the new work Chapter 34 Report 1600 Osgood Street—Building#37 ` North Andover,Massachusetts August 24,2004 Page 6 must comply. B. If the cost of the proposed work is greater than $100,000 then all new work must comply and the existing building must include an accessible public entrance, toilet room, telephone and drinking fountain (if public phones and drinking fountains are provided) (521 CMR Section 3.3.1(b)). C. If the cost of the proposed work is greater than 30%of the full and fair cash value of the existing building,the entire building is required to fully comply with 521 CMR (521 CMR Section 3.3.2). It is not possible at this time to determine the degree to which the new work will need to comply with accessibility requirements as the cost of the new work has not been provided. Therefore, the following guidance is provided under the assumption that all new work must comply in full with the requirements of 521 CMR. The ADA Guidelines are not enforced by the Commonwealth of Massachusetts, they can only be enforced through a civil lawsuit or complaint filed with the U. S. Department of Justice. Compliance with the ADA Guidelines is also triggered by renovations to the existing buildings. All renovations to the building must be made to ensure that, to the maximum extent feasible, the altered portions of the facility are readily accessible to and usable by individuals with disabilities(28 CFR Part 36 Section 36.402(a)). Alterations made to provide an accessible path of travel to altered areas and accessible facilities(i.e. provide accessible toilet facilities) are not required if the cost exceeds 20% of the total cost of the alteration (28 CFR Part 36 Section 36.403(f)). However, if the cost to meet these accessibility requirements does exceed 20%, alterations are still required to the maximum extent that the area can be made accessible without exceeding the 20%criteria(28 CFR Part 36 Section 36.403(g)). The ADA also contains less stringent dimensional requirements for some building elements in an existing building where it is infeasible to meet the requirements for new construction (ADA Section 4.1.6). -The existing entrance requires alteration in order to comply with the requirements for accessibility per 521 CMR 25.1. The vestibule, if retained in the alteration process, will require a minimum of 48" of clear space plus • the width of the door swinging into the vestibule space (521 CMR 25.3) in order to be accessible. .The-existing toilet rooms may require alteration in order to comply with ADA • Chapter 34 Report 1600 Osgood Street—Building#37 North Andover,Massachusetts August 24, 2004 Page 7 requirements as described in 521 CMR 30 for public toilet rooms. An accessible toilet room must provide at least 60" of clear floor space for wheelchair turning. A standard accessible toilet stall shall be at least 60" wide and 72" deep (521 CMR 30.6) and grab bars must be provided in accordance with 521 CMR 30.8. Th'a ADA requires a N467 drinking fountain when only 1 drinking fountain is N rovided on a floor (ADA Section 4.1.3(10)). However, 521 CMR only requires a drinking fountain that meets the requirements for a "lo" drinking fountain. 521 CMR 36.1.1 states that a"hi-lo"drinking fountain can be used if only one drinking fountain is provided on a floor but does not require it be used. 3404.19 "Bnergv Conservation? Ordinary repairs such as like-kind replacement of broken windows, broken doors, or broken skylights in an existing building are allowed without complying in full with the energy code. However, any window replacement that includes new jambs or new jamb liners does not qualify as an ordinary repair and must comply with 780 CMR 3407. The existing roof/ceiling assembly is not required to comply with current energy code requirements unless the existing roofing material is stripped off the roof deck (780 CMR 3407.4.3). 3408.0 Structural Requirements fOt`E s rtb"uildinps Buildings constructed under a permit issued prior to January 1, 1975 shall comply with 780 CMR 3408.0 and the building code applicable at the time the permit was issued. The provisions of 3408 will prevail should a conflict , in requirements with the previous building code rise. A registered professional engineer in structural engineering will be required to perform a structural analysis of the existing structural members and systems per 780 CMR 3408.3.2. The seismic hazard category of the building must be assigned once the occupant load and construction budget - have been determined (780 CMR 3408.1). J:\7780-00XO1'Building 37 Chapter 34 Report.doc Nicetta, Robert From: Ellen J Keller[ekeller@ozzyproperties.com] Sent: Tuesday, September 28, 2004 5:42 PM To: 'Bob Nicetta' Subject: FW: Building#37 Code Summary Building 37 Chapter 34 Report.... Bob, Please review the attached Chapter 34 which you requested. I will call you later this week to discuss. Thanks. Ellen J Keller VP-Commercial Real Estate Ozzy Properties, Inc. 3 Dundee Park Andover, MA 01810 phone: (978)475-4569 fax: (978)475-4638 motile: (978)423-1319 —Original Message From: Jay lerardi [mailto:jai rv,/sullivan.com] Sent: Thursday, August 26, 2004 9:03 AM To: ekellerc@ozzyproperties.com Subject: Building#37 Code Summary Ellen, I've attached our code summary for the existing Building#37 for your review. Feel free to contact our office should you have any questions or wish to discuss this report. Thanks, Jay Ierardi R.W. Sullivan, Inc. M/E/P/FP Engineering Code Consulting Union Wharf, Unit 302 343 Commercial Street Boston, MA 02109 JAI@RWSullivan.com Phone 617-523-8227 X 274 Fax 617-523-8016 Visit our Website at: hftp://vwwv.RWSullivan.com This communication is confidential and intended only for the recipient(s)in accordance within the scope of business. If you have received this communication in error, please delete it and notify us immediately. R.W. Sullivan, Inc. is not responsible for any undetectable alteration,