Loading...
HomeMy WebLinkAboutMiscellaneous - 1661 GREAT POND ROAD 4/30/2018/ BUILDING H LA : J �G�i Ger P�a ✓�2 . BUILDING FELE Location w/ No. Date e�—q 7—.!? 0e1'I b' • - TOWN OF NORTH ANDOVER • a �� v Certificate of Occupancy $ .» ,r-- { Building/Frame Permit Fee $ Foundation Permit Fee $ Other Permit Fee $ TOTAL $ Check# I c� ,/0' Building Inspector " i Coil]Monwe"lIth of has "Idilasetts Sheet Metal Permit Date: Permit-8 Lstirriated Job Cost: 0 r) Permit Fee: $ Plans Submitted: YES NO ! Flans Reviewed: XIS _ NO � I 13usinc,ss Llccnsc 11 196 Applicant License If Business Infor•nlation: Property Owncr/Job Location Information: Name: J&J Ileatlizg. & Alr Conditioning Na.mc: F� Street: 17 Arlington St.: Street: City/Town: Dracut, MA 018'26 City/Town: North Andover, MA 01845 Telephone: .97.8=454-8197 Telephone: A2. 8', G$''7, 9-G .3_S j Photo I.D. required / Copy of Plloto I.D. attached: . YES /NO j Sln'fClulfinl J-a / M-1-111lxcstricted license t✓ J-2 / M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft. /2-stories ol• less 1Zesii:tc�ztiul:"I Z"t'�iliuly Multi= atllily Condo /TOwnhouscs Other Col�uucl tial: Office__ Retail Industrial Educational 111strtutlonal O eller Square Footage: under 10,0.00 sq. ft. V over 10,000 sq. ft. Number- of Stories: Sheet wetal work to be co111,pletetl: New Work- Y Renovation: HVAC ✓ Nletal Watershed Roofing Kitchen Exhaust System _ -� Metal Chimney /Vents Air Balancing _ Provide detailed description of work to be done: __�<�-,Q,a-/% � i•i�.��•,��_l i�/,:7� l d�� Ul`-"to o r l� -F�,�- ;y U�� s y s T�,�,-, ��� ,INSURANCE COVERAGE: I have a current liability insurance policy or Its equivalentwhich meets the requirements of M.G.L. Ch. 112 Yes No❑ If you have checked Yes, indicate the type of coverage by checking the appropriate box below: A liability insurance policy Other type of indemnity ❑ Bond ❑ OWNER'S INSURANCE WAIVER: I am aware that the licensee does not have the Insurance coverage required by Chapter 112 of the Massachusetts General Laws, and that my gignature on this permit application waives this rcquirement. Check One Only Owner ❑ Agent ❑ Signature of Owner or Owner's Agent By checking this box❑, I hereby certify that all of the details and Information I have submitted(or entered) regarding this appilcatlon aro true and accurate to the best of my knowledge and that all shoot motal work and Installations performed undor the permit Issued for this applicatlon wlll be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Duct inspection required prior to insulation installation: YES NO Pl-oL,vcss lrtspections l�ai.c Comments Final b1spection ]Mite Comments Type of License: By �IGlasler Title ❑ Master-Restricted cityrrewn ❑Joumeyperson Signature of Licensee Permit It _ ❑Journeyperson ResLicted License Number: .> {p Fee$ CI Check at www.mass.c)ov/dpi Inspector Signature of Permit Approval 4 i The Commonwealth ofMassachusetts = u Department of Industrial Accidents I Congress Street,Suite 100 Boston,MA 02114-2017 www.mass.govldia 1Vorkers' Compensation insurance Affidavit: Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. � Applicant Information Please Print Legibly Name (Business/Organization/Individual): J & J Heating & Air Conditioning, Inc. Address: 17 Arlington Street City/State/Zip: Dracut, MA. 01826 Phone #: 978-454-8197 Are you an employer?Check the appropriate box: Type of project(required): l.�1 am a employer with 40 employees(full and/or part-time)."` 7. F1 New construction 2. t am a sole proprietor or partnership and have no employees working for me in 8. ❑ Remodeling i any capacity.(No workers'comp.insurance required.) 3.❑I am a homeowner doing all work myself.[No workers'comp.insurance required.]t 9. ❑Demolition 4.[jI am a homeowner and will be hiring contractors to conduct all work on my property. I will 10 ❑.Building addition ensure that all contractors either have workers'compensation insurance or are sole 11.[:]Electrical repairs Or additions proprietors with no employees. 12.E:]Plumbing repairs or additions 5.❑1 am a general contractor and I have hired the sub-contractors listed on the attached sheet. 13.❑'ROOF repairs These sub-contractors have employees and have workers'comp.insurance.$ 6.F11 We are a corporation and its officers have exercised their right ot'exeinption per MGL c. 14.❑Other 152,§1(4),and we have no employees.[No workers'comp.insurance required.] 'Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. $Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If,the sub-contractors have employees,they must provide their workers'coin p.policy number. I am fan employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: A.I.M. Mutual Insurance Policy#or Self-ins..Lie.#: -800-8006.553-20 .6 Expiration Date: 6/2/17 I Job Site Address:—J&& dCity/State/Zip: / �, Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). O/O7 Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-yea�i pt isonmet ,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against% e violator. A cy of this statement may be forwarded to the Office of Investigations Of the DIA for insurance coverag verification. I do here4[&ar at n&r the ai anti pet: 'lti of perjur that the information provided above is true and correct. Si nature: i Date: , Phone#: 7 — 19 Official use only. Do not write in this area,to be completed by city lir town official. City or Town: Permit/License# I Issuing Authority(circle one): 1.Board of Health 2.Building Departint 3.City/Town Clerk 4. Electrical Inspector 5. Plumbing Inspector 6.Other n Contact Person: Phone#: i i .ac o® CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDD/YYYY) I r 6/2/2016 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS I CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER - NA ME ACT Laurence Hall, CIC Sennott Insurance Agency PHONE (978)$$7_4900 FAX (978)887-2404 C No: 16 South Main Street E-MAIL iarryhall@sennottinsurance.com ADDRESS: T y s BOX 457 INSURERS AFFORDING COVERAGE NAIC# INSURED INURED ld MA 01983 INSURERAGreat American Alliance Ins.Co -INSURER B:Safet iris CO J&J Heating & Air Conditioning, Inc. (NSURERCA.I.M. Mutual Ins Co 17 Arlington Street INSURER D: INSURER E: Dracut MA 01826 INSURER F: COVERAGES CERTIFICATE NUMBER:2016-2017 Renewal Certs REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THF INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS_ AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR JA SUER LTR TYPE OF INSURANCE POLICY NUMBER MMLDDY EFF MMLRD EXP LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 ACLAIMS-MADE OCCUR DAMAGE TO RENTED PREMISES Ea occurrence 300,000 00 PAC6418906-10 6/1/2016 6/1/2017 MED EXP(Any one person) $ 10,000 PERSONAL&ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 POLICY JECT LOC - PRODUCTS-COMP/OPAGG $ 2,000,000 OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT Ea accident $ 1,000,000 ANY AUTO B ALL OWNED _ BODILY INJURY(Per person) $ SCHEDULED AUTOS X AUTOS 2434550 6/1/2016 6/1/2017 BODILY INJURY(Per accident) $ X HIRED AUTOS X AUUTOSWNED PROPERTY DAMAGE $ Per accident I $ X UMBRELLAiLIAB X OCCUR EACH OCCURRENCE $ 2,000,000 EXCESS LI!IB AGGREGATE $ 2,000,000 A CLAIMS-MADE DED RETENTION UM 6418958-09 6/1/2016 6/1/2017 $ WORKERS COMPENSATION I AND EMPLOYERS'LIABILITY Y/N X STATUTE ORH ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $ 1,000,000 C OFFICER/MEMBER EXCLUDED? a N/A (MIf andatory In NH) WMI-800-8006553-2016 6/2/2016 6/2/2017 E.L.DISEASE-EA EMPLOYE $ 1 000 000 yes,describe under DESCRIPTION OF,OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 1,000,000 DESCRIPTION SOF OPERATIONS/LOCATIONS/VEHICLES (ACORD 10 ,Additional Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Evidence of Insurance THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE L Hall, CIC/LH2 ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD INS025 ont4nii 1. COMMONWEALTH OF MASSACHUSETTS ' a - • BOARS OE SHEET METAL WC)RKERS, ISSUES THE EOLLOWING LICEN SEASA MASTER UNRE$TRLCTED.: ' ERIE R Ku qE . ARLING N0 &AC DRAC.UT IVA 01826 33� 1568 Q512E3/2018 3 744 IISi F'I; rr7 DRIVER'S LICENSE L , .., 4'i ISS- J CNU 4,NUMBER t�05 03 201E NONE S9965587 M,CXP 3 zo21 05 14 l '`1•� l 17.RFST 1 2 6 1 9 8,0...,. 97 t t7 "rDM NONC sex M a�NGT 6.09...'_ KLINE ..... .. z ERIC RJ. . y y i"1 n 106 MEADOW CREEK DR ' J �9�ilglq i DRACUTMAi 01026 (f t�, 'OU 05.041p 16 Rcv 07 15"2oo9 lo l.c fiwii A, a P C�JUJf SII"lI T y. l 1k;.. .. SHEE1St1 - IS ilJEkajHE �!.'ULL0VUING LICCNSE AS A C31;6.3.IPdr�ti ': GI01 ARD T AVO1 I I- 1J...•: JJ -EATifi`JC AIR CONDITIORIINCv INC : 17 aF�LtNV i Of�l 9�1 PZEd`i „3 D,R GUl', IUTA 01826 19 01111/ Q'P.f� r 12401 Load Short Form Job: 1661 Great pond Rd " wrightsoft Date: Aug 18 2016 Entire House By: J&J Heating and Air Conditioning 17 Arlington st, Dracut,ma 1826 For: TKZ LLC 78 Great Pond Rd, North Andover, MA 01845 Htg Clg Infiltration Outside db (°F) 12 88 Method Simplified Inside db (°F) 68 75 Construction quality Average Design TD (°F) 56 13 Fireplaces 0 Daily range - L Inside humidity (%) 50 50 Moisture difference (gr/Ib) 43 28 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80AFUE Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 OF Total cooling 0 Btuh Actual air flow 861 cfm Actual air flow 861 cfm Air flow factor 0.035 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.91 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) kitchen 180 2217 2163 77 99 hall 60 403 72 14 3 living room 195 3061 2127 106 97 dinning room 225 1541 1175 53 54 stairs 105 597 106 21 5 entry 180 3062 1872 106 85 m bath 108 1688 1050 58 48 laun 72 503 187 17 9 elev 60 419 156 15 7 Loft 264 3373 976 117 44 Bedroom 2 180 2623 3754 91 171 2nd stairs 105 628 252 22 11 1/2 bath 90 538 216 19 10 master bed 330 4216 4802 146 219 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .•_ wri htsoft� 2016-Aug-18 07:48:08 a„s 9 Right-Suite®Universal 2015 15.0.23 RSU05790 Page 1 ACCK ...top\M-J-Copy\Tara Leigh 52 Ciderpress way.rup Calc=MJ8 Front Door faces: N Entire House d 2154 24871 18907 861 861 Other equip loads 8696 2389 Equip. @ 0.93 RSM 19720 Latent cooling 2134 TOTALS 2154 33567 21854 861 861 i Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Aug-18 07:48:08wri htsof ® Right-Suite®Universal 2015 15.0.23 RSU05790 Page 2 ACCA ...top\M-J-Copy\Tara Leigh 52 Ciderpress way.rup Calc=MJ8 Front Door faces: N Building Anal sis Job: 1661 Great pond Rd wrightsoft® y Date: Aug 18 2016 Entire House By: J&J Heating and Air Conditioning 17 Arlington st,Dracut,ma 1826 s • • • i For: TKZ LLC 78 Great Pond Rd, North Andover, MA 01845 11 - • o • • Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 68 75 Elevation: 30 ft Design TD (°F) 56 13 Latitude: 420N Relative humidity (%) Outdoor: Heating Cooling Moisture difference (gr/Ib) 420 7 20 8 Dry bulb (°F) 12 88 Infiltration: Daily range6F) - 72 ( L ) Method Simplified Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ft2 Btuh % of load Walls 3.6 7145 21.3 Glazing 16.7 3102 9.2 Doors 21.7 911 2.7 f Ceilings 1.4 1748 5.2s ` Floors 1.4 1310 3.9 Infiltration 2.6 5701 17.0 '' Ducts 4955 14.8 Piping 0 0 Humidification 5312 15.8 Ventilation 3385 10.1 ° Adjustments 0 ^� Total 33567 100.0 ME=117-1171 Component Btuh/ft2 Btuh % of load Walls 1.0 1966 9.2 w Glazing 43.6 8101 38.0 Doors 10.3 434 2.0 Ceilings 1.3 1572 7.4 Floors 0.3 297 1.4 Infiltration 0.3 646 3.0 Ducts 3631 17.0 >` Ventilation 0 0 Internal gains 2260 10.6 , Blower 2389 11.2 Adjustments 0 Total 1 21296 100.0 ter- Latent Cooling Load = 2134 Btuh Overall U-value= 0.060 Btuh/ft2--F Data entries checked. WI'1 htsoftm 2016-Aug-18 07:48:08 9 Right-Suit,9 Universal 2015 15.0.23 RSU05790 Page 1 /CC;K'.,.top\M-J-Copy\Tara Leigh 52 Ciderpress way.rup Calc=MJ8 Front Door faces: N F wri9 htsoft Component Constructions Job: 1661 Great pond Rd Date: Aug 18 2016 Entire House By: J&J Heating and Air Conditioning 17 Arlington st, Dracut,ma 1826 For: TKZ LLC 78 Great Pond Rd, North Andover, MA 01845 Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 68 75 Elevation: 30 ft Design TD (°F) 56 13 Latitude: 420N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 42.7 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb (°F) - 72 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area 1.1-value Insul R Htg HTM Loss Clg HTM Gain ft2 Btuh/t2-°F ft2-°F/Btuh Btuh/ft2 Btu Btuh/ft2 Btu Walls 12F-Osw:Frm wall,wd ext,1/2"wood shth,r-21 cav ins,1/2" ne 342 0.065 21.0 3.61 1236 0.99 340 gypsum board int fnsh,2"x6"wood frm,16"o.c.stud se 737 0.065 21.0 3.61 2664 0.99 733 sw 252 0.065 21.0 3.61 911 0.99 251 nw 646 0.065 21.0 3.61 2335 0.99 642 all 1977 0.065 21.0 3.61 7145 0.99 1966 Partitions (none) Windows 2 glazing,clr outr,air gas,wd frm mat,clr innr,1/4"gap,1/8"thk:2 ne 90 0.300 0 16.7 1501 38.0 3423 glazing,clr outr,air gas,wd frm mat,clr innr, 1/4"gap, 1/8"thk; se . 42 0.300 0 16.7 701 48.7 2047 6.67 ft head ht sw 54 0.300 0 16.7 901 48.7 2632 all 186 0.300 0 16.7 3102 43.6 8101 Doors 11 DO:Door,wd s type sw 42 0.390 0 21.7 911 10.3 434 Ceilings 16B-38ad:Attic ceiling,asphalt shingles roof mat,r-38 ceil ins,1/2" 1209 0.026 38:0. 1.45 1748 1.30 1572 gypsum board int fnsh Floors 19A-38bswp:Fir floor,frm fir,10"thkns,hrd wd fir fnsh,r-38 cav 945 0.029 38.0 1.39 1310 0.31 297 ins,tight bsmt ovr ,1 Wrl ht:SOft° g 2016-Aug-18 07:48:08 g Ri ht-Suite®Universal 2015 15.0.23 RSU05790 ACCA ...top\M-J-Copy\Tara Leigh 52 Ciderpress way.rup Calc=MJ8 Front Door faces: N Page 1 wri htsoft Component Constructions Job: 1661 Great pond Rd 9 Date: Aug 18 2016 kitchen By: J&J Heating and Air Conditioning 17 Arlington st,Dracut,ma 1826 For: TKZ LLC 78 Great Pond Rd, North Andover, MA 01845 Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 68 75 Elevation: 30 ft Design TD (°F) 56 13 Latitude: 420N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 42.7 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb (°F) - 72 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain W Btuh/ft2-°F ft2-°F/13tuh BWh/ftz Btu Btu h/ft2 Btuh Walls 12F-Osw:Frm wall,wd ext,1/2"wood shth,r-21 cav ins,1/2" ne 90 0.065 21.0 3.61 325 0.99 90 gypsum board int fnsh,2"x6"wood frm,16"o.c.stud nw 135 0.065 21.0 3.61 488 0.99 134 all 225 0.065 21.0 3.61 813 0.99 224 Partitions (none) Windows 2 glazing,cir outr,air gas,wd frm mat,clr innr,1/4"gap,1/8"thk:2 ne 18 0.300 0 16.7 300 38.0 685 glazing,clr outr,air gas,wd frm mat,clr innr,1/4"gap, 1/8"thk; 6.67 ft head ht Doors (none) Ceilings (none) Floors 19A-38bswp:Fir floor,frm fir,10"thkns,hrd wd fir fnsh,r-38 cav 180 0.029 38.0 1.39 249 0.31 57 ins,tight bsmt ovr' 2016-Aug-18 07:48:08 ,t wrightsoft" Right-Suite®Universal 2015 15.0.23 RSU05790 Page 2 ACCP. ...top\M-J-Copy\Tara Leigh 52 Ciderpress way.rup Calc=MJ8 Front Door faces: N wri htsoft- Component Constructions Job: 1661 Great pond Rd g Date: Aug 18 2016 hall By: J&J Heating and Air Conditioning 17 Arlington st, Dracut,ma 1826 • e e For: TKZ LLC 78 Great Pond Rd, North Andover, MA 01845 Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 68 75 Elevation: 30 ft Design TD (°F) 56 13 Latitude: 420N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 42.7 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L } Method Simplified Wet bulb (°F) - 72 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft2 Btuh/ftz-°F ft2-°F/Btuh Btu h/ft2 Btu Btuh/ftz Btu Walls 12F-Osw:Frm wall,wd ext,1/2"wood shth,r-21 cav ins,1/2" nw 45 0.065 21.0 3.61 163 0.99 45 gypsum board int fnsh,2"x6"wood frm,16"o.c.stud Partitions (none) Windows (none) Doors (none) Ceilings (none) Floors 19A-38bswp:Fir floor,frm fir,10"thkns,hrd wd fir fnsh,r-38 cav 60 0.029 38.0 1.39 83 0.31 19 ins,tight bsmt ovr 08 wrightsoft" Right-Suite®Universal 2015 15.0.23 RSU05790 2016-Aug-18 07:age Page 3 3 ACCP, ...top\M-J-Copy\Tara Leigh 52 Ciderpress way.rup Calc=MJ8 Front Door faces: N wri htsoft Component Constructions Job: 1661 Great pond Rd 9 Date: Aug 18 2016 living room By: J&J Heating and Air Conditioning 17 Arlington st,Dracut,ma 1826 For: TKZ LLC 78 Great Pond Rd, North Andover, MA 01845 IN 1� • e • e Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 68 75 Elevation: 30 ft Design TD (°F) 56 13 Latitude: 420N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 42.7 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb (°F) - 72 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain W Btuh/ft2-1F ft2-°FBtuh MOM Btu Btuh/112 Btu Walls 12F-Osw:Frm wall,wd ext,1/2"wood shth,r-21 cav ins,1/2" ne 99 0.065 21.0 3.61 358 0.99 98 gypsum board int fnsh,2"x6"wood frm,16"o.c.stud se 117 0.065 21.0 3.61 423 0.99 116 nw 72 0.065 21.0 3.61 260 0.99 72 all 288 0.065 21.0 3.61 1041 0.99 286 Partitions (none) Windows 2 glazing,clr outr,air gas,wd frm mat,clr innr,1/4"gap,1/8"thk:2 ne 36 0.300 0 16.7 600 38.0 1369 glazing,clr outr,air gas,wd frm mat,clr innr,1/4"gap, 1/8"thk; 6.67 ft head ht Doors (none) Ceilings (none) Floors 19A-38bswp:Fir floor,frm fir,10"thkns,hrd wd fir fnsh,r-38 cav 195 0.029 38.0 1.39 270 0.31 61 ins,tight bsmt ovr wrightsoft°' Right-SuiteO Universal 2015 15.0.23 RSU05790 2016-Aug-18 07:48:08Page 4 ACCK ...top\M-J-Copy\Tara Leigh 52 Ciderpress way.rup Calc=MJ8 Front Door faces: N Component Constructions Job: 1661 Great pond Rd wrlghtsoft� Date: Aug 18 2016 dinning room By: J&J Heating and Air Conditioning 17 Arlington st,Dracut,ma 1826 MEMEEMEMEMEEM For: TKZ LLC 78 Great Pond Rd, North Andover, MA 01845 Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 68 75 Elevation: 30 ft Design TD (°F) 56 13 Latitude: 420N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr Ib) 42.7 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb (°F) - 72 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft2 Btuh/(t2-°F ft2-°F/Btuh Btuh/ftz Btu Btuh/ft2 Btu Walls 12F-Osw:Frm wall,wd ext,1/2"wood shth,r-21 cav ins,1/2" se 117 0.065 21.0 3.61 423 0.99 116 gypsum board int fnsh,2"x6"wood frm,16"o.c.stud Partitions (none) Windows 2 glazing,clr outr,air gas,wd frm mat,clr innr,1/4"gap,1/8"thk:2 se 18 0.300 0 16.7 300 48.7 877 glazing,cir outr,air gas,wd frm mat,clr innr,1/4"gap,1/8"thk; 6.67 ft head ht Doors (none) Ceilings (none) Floors 19A-38bswp:Flr floor,frm flr,10"thkns,hrd wd flr fnsh,r-38 cav 225 0.029 38.0 1.39 312 0.31 71 ins,tight bsmt ovr ti wri htsoft' 2016-Aug-18 07:48:08 9 Right-Suite@ Universal 2015 15.0.23 RSU05790 Page 5 /�CPa ...top\M-J-Copy\Tara Leigh 52 Ciderpress way.rup Calc=MJ8 Front Door faces: N wrightsoft- Component Constructions Job: 1661 Great pond Rd Date: Aug 18 2016 stairs By: J&J Heating and Air Conditioning 17 Arlington st, Dracut,ma 1826 I For: TKZ LLC 78 Great Pond Rd, North Andover, MA 01845 Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 68 75 Elevation: 30 ft Design TD (°F) 56 13 Latitude: 420N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 42.7 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb (°F) - 72 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft2 Btuh/ft2-°F ftz"FBtuh Btuh/112 Btu Btuh/ft2 Btu Walls 12F-Osw:Frm wall,wd ext, 1/2"wood shth,r-21 cav ins,1/2" se 63 0.065 21.0 3.61 228 0.99 63 gypsum board int fnsh,2"x6"wood frm,16"o.c.stud Partitions (none) Windows (none) Doors (none) Ceilings (none) Floors 19A-38bswp:Flr floor,frm flr,10"thkns,hrd wd flr fnsh,r-38 cav 105 0.029 38.0 1.39 146 0.31 33 ins,tight bsmt ovr ti 2016-Aug-18 07:48:08wri htsoft Right-Suite®Universal 2015 15.0.23 RSU05790 Page 6 19GCk ...top\M-J-Copy\Tara Leigh 52 Ciderpress way.rup Calc=MJ8 Front Door faces: N fVf wri htsoft- Component Constructions Job: 1661 Great pond Rd 9 Date: Aug 18 2016 entry By: J&J Heating and Air Conditioning 17 Arlington st,Dracut,ma 1826 For: TKZ LLC 78 Great Pond Rd, North Andover, MA 01845 Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 68 75 Elevation: 30 ft Design TD (°F) 56 13 Latitude: 420N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 42.7 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb ( F) - 72 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft2 Btuh/ft2-°F ft2-°F/Btuh Btuh/V Btu Btuh/ft2 Btu Walls 12F-Osw:Frm wall,wd ext,1/2"wood shth,r-21 cav ins,1/2" se 108 0.065 21.0 3.61 390 0.99 107 gypsum board int fnsh,2"x6"wood frm,16"o.c.stud sw 75 0.065 21.0 3.61 271 0.99 75 all 183 0.065 21.0 3.61 661 0.99 182 Partitions (none) Windows 2 glazing,clr outr,air gas,wd frm mat,clr innr,1/4"gap,1/8"thk:2 sw 18 0.300 0 16.7 300 48.7 877 glazing,clr outr,air gas,wd frm mat,clr innr,1/4"gap, 1/8"thk; 6.67 ft head ht Doors 11 DO:Door,wd sc type sw 42 0.390 0 21.7 911 10.3 434 Ceilings (none) I Floors 19A-38bswp:Fir floor,frm fir,10"thkns,hrd wd flr fnsh,r-38 cav 180 0.029 38.0 1.39 249 0.31 57 ins,tight bsmt ovr t a 2016-Aug-18 07:48:08WPI htsoft Right-Suite®Universal 2015 15.0.23 RSU05790 Page 7 ACCP, ...top\M-J-Copy\Tara Leigh 52 Ciderpress way.rup Calc=MJ8 Front Door faces: N wrightsoftComponent Constructions Job: 1661 Great pond Rd m bath Bate: Aug 18 2016 By: J&J Heating and Air Conditioning 17 Arlington st,Dracut,ma 1826 i For: TKZ LLC 78 Great Pond Rd, North Andover, MA 01845 ns • e • e Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 68 75 Elevation: 30 ft Design TD (°F) 56 13 Latitude: 420N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 42.7 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb (°F) - 72 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft2 Btuh/ftl-°F ft2-°F/Btuh Btuh/ftz Btu Btuh/ft2 Btu Walls 12F-Osw:Frm wall,wd ext,1/2"wood shth,r-21 cav ins,1/2" ne 72 0.065 21.0 3.61 260 0.99 72 gypsum board int fnsh,2"x6"wood frm,16"o.c.stud nw 63 0.065 21.0 3.61 228 0.99 63 all 135 0.065 21.0 3.61 488 0.99 134 Partitions (none) Windows 2 glazing,cir outr,air gas,wd frm mat,clr innr,1/4"gap,1/8"thk:2 ne 12 0.300 0 16.7 200 38.0 456 glazing,clr outr,air gas,wd frm mat,clr innr,1/4"gap, 1/8"thk; 6.67 ft head ht. Doors (none) Ceilings 16B-38ad:Attic ceiling,asphalt shingles roof mat,r-38 ceil ins,1/2" 108 0.026 38.0 1.45 156 1.30 140 gypsum board int fnsh Floors (none) Wri ht:SOft 2016-Aug-18 07:48:08 9 Right-Suite®Universal 2015 15.0.23 RSU05790 ACCA ...top\M-J-Copy\Tara Leigh 52 Ciderpress way.rup Calc=MJ8 Front Door faces: N Page 8 wri htsoft- Component Constructions Job: 1661 Great pond Rd 9 Date: Aug 18 2016 laun By: J&J Heating and Air Conditioning 17 Arlington st, Dracut,ma 1826 For: TKZ LLC 78 Great Pond Rd, North Andover, MA 01845 d • • Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 68 75 Elevation: 30 ft Design TD (°F) 56 13 Latitude: 420N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 42.7 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb (°F) - 72 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain W Btuh/ft2-°F ft2-°F/Btuh Btuh/112 Btu Btuh/ft2 Btu Walls 12F-Osw:Frm wall,wd ext,1/2"wood shth,r-21 cav ins,1/2" nw 42 0.065 21.0 3.61 152 0.99 42 gypsum board int fnsh,2"x6"wood frm,16"o.c.stud Partitions (none) Windows (none) Doors (none) Ceilings 16B-38ad:Attic ceiling,asphalt shingles roof mat,r-38 ceil ins,1/2" 72 0.026 38.0 1.45 104 1.30 94 gypsum board int fnsh Floors (none) wrightsoft' Right-SuiteO Universal 2015 15.0.23 RSU05790 2016-Aug-18 07:48:08Page 9 .�� ...top\M-J-Copy\Tara Leigh 52 Ciderpress way.rup Calc=MJ8 Front Door faces: N wri htsoft- Component Constructions Job: 1661 Great pond Rd g Date: Aug 18 2016 elev By: J&J Heating and Air Conditioning 17 Arlington st, Dracut,ma 1826 For: TKZ LLC 78 Great Pond Rd, North Andover, MA 01845 ,10 Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 68 75 Elevation: 30 ft Design TD (°F) 56 13 Latitude: 420N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 42.7 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb (°F) - 72 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft2 Btuh/ftz-°F ft2-°FBtuh Btuh/ft2 Btu Btuh/ftz Btuh Walls 12F-Osw:Frm wall,wd ext,1/2"wood shth,r-21 cav ins,1/2" nw 35 0.065 21.0 3.61 126 0.99 35 gypsum board int fnsh,2"x6"wood frm,16"o.c.stud Partitions (none) Windows (none) Doors (none) Ceilings 166-38ad:Attic ceiling,asphalt shingles roof mat,r-38 ceil ins,1/2" 60 0.026 38.0 1.45 87 1.30 78 gypsum board int fnsh Floors (none) n2016-Aug-18 07:48:08 wrightsoW Right-Suite®Universal 2015 15.0.23 RSU05790 Page 10 ACCK ...top\M-J-Copy\Tara Leigh 52 Ciderpress way.rup Calc=MJ8 Front Door faces: N Component Constructions Job: 1661 Great pond Rd wrightsoft Date: Aug 18 2016 Loft By: J&J Heating and Air Conditioning 17 Arlington st, Dracut,ma 1826 For: TKZ LLC 78 Great Pond Rd, North Andover, MA 01845 Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 68 75 Elevation: 30 ft Design TD (°F) 56 13 Latitude: 420N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 42.7 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb (°F) - 72 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft2 Btuh/ftz°F W-T/Btuh Btuh/ft2 Btu Btuh/ft2 Btu Walls 12F-Osw:Frm wall,wd ext,1/2"wood shth,r-21 cav ins,1/2" se 27 0.065 21.0 3.61 98 0.99 27 gypsum board int fnsh,2"x6"wood frm,16"o.c.stud sw 108 0.065 21.0 3.61 390 0.99 107 nw 198 0.065 21.0 3.61 716 0.99 197 all 333 0.065 21.0 3.61 1203 0.99 331 Partitions (none) Windows (none) Doors (none) Ceilings 16B-38ad:Attic ceiling,asphalt shingles roof mat,r-38 ceil ins,1/2" 264 0.026 38.0 1.45 382 1.30 343 gypsum board int fnsh Floors (none) 2016-Aug-18 07:48:08wri htsofRight-Suite®Universal 2015 15.0.23 RSU05790 Page 11 ACCK :.:top\M-J-Copy\Tara Leigh 52 Ciderpress way.rup Calc=MJ8 Front Door faces: N wri htsoft Component Constructions Job: 1661 Great pond Rd 9 Date: Aug 18 2016 Bedroom 2 By: J&J Heating and Air Conditioning 17 Arlington st, Dracut,ma 1826 For: TKZ LLC 78 Great Pond Rd, North Andover, MA 01845 I ME i , Magi • • • e Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 68 75 Elevation: 30 ft Design TD (°F) 56 13 Latitude: 420N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 42.7 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb (°F) - 72 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain 112 Btuh/V°F ft2-°F/Btuh Btu h/111 Btu MON Btuh Walls 12F-Osw:Frm wall,wd ext,1/2"wood shth,r-21 cav ins,1/2" se 84 0.065 21.0 3.61 304 0.99 84 gypsum board int fnsh,2"x6"wood frm,16"o.c.stud sw 69 0.065 21.0 3.61 249 0.99 69 all 153 0.065 21.0 3.61 553 0.99 152 Partitions (none) Windows 2 glazing,clr outr,air gas,wd frm mat,clr innr,1/4"gap,1/8"thk:2 sw 36 0.300 0 16.7 600 48.7 1754 glazing,clr outr,air gas,wd frm mat,clr innr, 1/4"gap,1/8"thk; 6.67 ft head ht Doors (none) Ceilings 1613-38ad:Attic ceiling,asphalt shingles roof mat,r-38 ceil ins,1/2" 180 0.026 38.0 1.45 260 1.30 234 gypsum board int fnsh Floors (none) 2016-Aug-18 07:48:08 wrightsofit' Right-Suite®Universal 2015 15.0.23 RSU05790 Page 12 ACCT, ...top\M-J-Copy\Tara Leigh 52 Ciderpress way.rup Calc=MJ8 Front Door faces: N Component Constructions Job: 1661 Great pond Rd WrightsOft� p Date: Aug 182016 2nd stairs By: J&J Heating and Air Conditioning 17 Arlington st,Dracut,ma 1826 � e o • For: TKZ LLC 78 Great Pond Rd, North Andover, MA 01845 Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 68 75 Elevation: 30 ft Design TD (°F) 56 13 Latitude: 420N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 42.7 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb (°F) - 72 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ftz Btuh/ft2-°F ft2-°F/Btuh Btuh/ft2 Btu Btuh/rtz Btu Walls 12F-Osw:Frm wall,wd ext,1/2"wood shth,r-21 cav ins,1/2" se 49 0.065 21.0 3.61 177 0.99 49 gypsum board int fnsh,2"W'wood frm,16"o.c.stud Partitions (none) Windows (none) Doors (none) Ceilings 16B-38ad:Attic ceiling,asphalt shingles roof mat,r-38 ceil ins,1/2" 105 .0.026 38.0 1.45 152 1.30 137 gypsum board int fnsh Floors (none) wri htsoft' 2016-Aug-1807:48:08 9 Right-Suite®Universal 2015 15.0.23 RSU05790 Page 13 ACCA ...top\M-J-Copy\Tara Leigh 52 Ciderpress way.rup Calc=MJ8 Front Door faces: N wri htsoft- Component Constructions Job: 1661 Great pond Rd 9 1/2 bath Bate: Aug 182016 By: J&J Heating and Air Conditioning 17 Arlington st,Dracut,ma 1826 { For: TKZ LLC 78 Great Pond Rd, North Andover, MA 01845 Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 68 75 Elevation: 30 ft Design TD (°F) 56 13 Latitude: 420N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 42.7 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb (°F) - 72 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft2 Btuh/ft2-°F ft2-°FBtuh Btuh/112 Btuh Btuh/ft2 Btu Walls 12F-Osw:Frm wall,wd ext,1/2"wood shth,r-21 cav ins,1/2" se 42 0.065 21.0 3.61 152 0.99 42 gypsum board int fnsh,2"x6"wood frm,16"o.c.stud Partitions (none) Windows (none) Doors (none) Ceilings 166-38ad:Attic ceiling,asphalt shingles roof mat,r-38 ceil ins,1/2" 90 0.026 38.0 1.45 130 1.30 117 gypsum board int fnsh Floors (none) wrightsoft" Right-Suited 2016-Aug-18 07:48:08 Universal 2015 15.0.23 RSU05790 Page 14 ACCk ...top\M-J-Copy\Tara Leigh 52 Ciderpress way.rup Calc=MJ8 Front Door faces: N htsoftx wri Component Constructions Job: 1661 Great pond Rd Dae: Aug9 t 18 2016 master bed By: J&J Heating and Air Conditioning 17 Arlington st, Dracut,ma 1826 For: TKZ LLC 78 Great Pond Rd, North Andover, MA 01845 Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 68 75 Elevation: 30 ft Design TD (°F) 56 13 Latitude: 420N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 42.7 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb (°F) - 72 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain W Btuh/ft2-°F ft2-°FBtuh Btuh/ftz Btu Btuh/rtz Btuh Walls 12F-Osw:Frm wall,wd ext,1/2"wood shth,r-21 cav ins,1/2" ne 81 0.065 21.0 3.61 293 0.99 81 gypsum board int fnsh,2"x6"wood frm,16"o.c.stud se 130 0.065 21.0 3.61 470 0.99 129 nw 56 0.065 21.0 3.61 202 0.99 56 all 267 0.065 21.0 3.61 965 0.99 266 Partitions (none) Windows 2 glazing,clr outr,air gas,wd frm mat,clr innr,1/4"gap,1/8"thk:2 ne 24 0.300 0 16.7 400 38.0 913 glazing,clr outr,air gas,wd frm mat,clr innr, 1/4"gap,1/8"thk; se 24 0.300 0 16.7 400 48.7 1170 6.67 ft head ht all . 48 0.300 0 16.7 801 43.4 2082 Doors (none) Ceilings 1613-38ad:Attic ceiling,asphalt shingles roof mat,r-38 ceil ins,1/2" 330 0.026 38.0 1.45 477 1.30 429 gypsum board int fnsh Floors (none) ti wri htsoftA 2016-Aug-18 07:48:08 9 Right-Suite®Universal 2015 15.0.23 RSU05790 ACCK ...top\M-J-Copy\Tara Leigh 52 Ciderpress way.rup Calc=MJ8 Front Door faces: N Page 15