Loading...
HomeMy WebLinkAboutMiscellaneous - 17 Bradford Street Ac% Co4(`F(cc -X.TT�r-7l�2 ` . W/1-6 1 J - _ APPLICATION FOR PERMIT TO WE., — NORTH ANDOVER, MASS. �� `�/✓' � l��l. PAGE 1 -T 2 RECORD OF OWNERSHIP (DATE BOOK 'PAGE WAP 446- ,O y C. LOT NO. l�O r' IS F1P0. 93 33ab I I I� r ZONE +,. 1 1. SUB DIV. LOT NO. �} 1 pWIJIE2S P�SSsEK IjotTN 1 1' PURPOSE OF BUILDING LOCATION It SiDrJ SOVTN Q�QAOFOQp S}• OWNER'S NO. OF STORIES SIZE NAME t6N� P ,� PAME.LI� A. Ca N i1-L- _ ¢ OWNER'S ADDRESS BASEMENT OR SLAB \JAR 'YVISM ARCHITECT'S NAME SIZE OF FLOOR TIMBERS IST aZ10,, 2ND o1X 10. 3RD BUILDER'S NAME SPAN I 10 C>C 1 S'� FL A5 M%U//� Ow N E 2 DISTANCE TO NEAREST BUILDING "1 O 1 .}/_. JAC A,dT Lct- BCS-'CIt DIMENSIONS OF SILLS a --�--- DISTANCE FROM STREET 1 POSTS DISTANCE FROM LOT LINES-,!,,,E S REAR gL oo I GIRDERS 1_"x I a ' �p1 R'�°�'�'�1- 1 l8 THICKNESS � AREA OF LOT �3 S(p L4 5q /.�- FRONTAGE�04 mss/ HEIGHT OF FOUNDATION p h SIZE OF FOOTING a � Z��`�� al u-, x all IS BUILDING NEW TO a11r .IB MATERIAL OF CHIMNEY a BUILDING ADDITIONQLC�C. IJ o ''-Vii'-�"'• -IS BUILDING ALTERATION IS BUILDING ON SOLID OR FILLED LAND - # IJ b WILL BUILDING CONFORM TO REQUIREMENTS OF CODE IS BUILDING CONNECTED TO TOWN WATER Y�5 OARD OF APPEALS ACTION. IF ANY IS BUILDING CONNECTED TO TOWN SEWER YES ..t Na1�1r✓ IS BUILDING CONNECTED TO NATURAL GAS LINE y Ej 3 PROPERTY INFORMATION INSTRUCTIONS LAND COST Soo., C'5-' 69 % EE BOTH SIDES EST. BLDG. COST 17 ` FDAEST. BLDG. COST PER SQ. FT. ` i AGE I FILL OUT SECTIONS i - 3 f �� f `;.s•. ,fir DUE FRAME PERMIT S EST. BLDG. COST PER ROOM AGE 2 FILL OUT SECTIONS 1 - 12 {IYE• �w�+ `� SEPTIC PERMIT NO. /v//q t`. �LECTRIC METEPS MUST BE ON OUTSIDE OF BUILDING 4 APPROVED BY _ ATTACHED GARAGES MUST CONFORM TO STATE FIRE REGULATIONS �LANS MUST BE FILED AND APPROVED BY BUILDING INSPECTOR DATE FI ED C Y� BOARD OF HEALTH u SIGNATURE F OWNER OR AUTHORIZED AGENT 411 FEE 21 PLANNING BOARD PERMIT GRANTED -- �. SOARD OF SELECTMEN SUILDING INBPECTOR f= OCCUPANCY R BUILDING RECORD SINGLE FAMILY 12 MULTI. FAMILY STORIES ' APARTMENTS OFFICES LOT SECTION MUST SHOW EXACT r LINES DIMENSIONS OF ~ � EXACT I„-';�� ---..•.; — AND RAGES, ETC. SUP DIMENSIONS OF LOT AND DISTANCE FROM CONSTRUCTION ERIMPOSED. THIS REP BUILDINGS, WITH PORCHES, ,�•:.� LACES PLOT PLAN. GA- ' 2 fOUNDATION CONCRETE r��•,>,, '' 8 INTERIOR FINISH�;.�r,•... ",j �(I CONCR—BI'K. a ? BRICK OR S7 �— PINE ONE r"'.'••: PIERS HARDW p _ X PLA5TER ' '•�y,�=r' DRY_WALL X — f,. ,_Mr,"i 3 UNFIN. K BASEMENT I ,;%' �•�+� AREA FULL FIN. BMi AREA 1.1 {'�V•�'' NO BM'i FIN. AT71C AREA HEA �•� .'•�” FIRE PLACES r;^r•'f� D ROOM � MODERN KITCHEN WALLS CLAP 9 FLOORS � .c"Nra•,,•S;� BOARDS P DROP SIDING B —1 1 2 3 CONCRETE -'=P WOOD SHINGLES —I_ ' q ASPHALT I EARTH ' S DING ASBESTOS SIDING HARD——l D— 1olCOMIAC VERT. SIDING — %.%'r-4;r" ASPH. TILE STUCCO ON M ASONRY coke s,•-.^•q•^c; ON FRAME B I K N MAS N Y ATTIC STRS. d FLOOR 9 �'?; o � it ff,.^ BRICK ON FRAME CONC. IR CINDER BLK. 1 STONE ON MASONRY raw• Z.gff P ,rf p STONE ON FRAME WIRING p } • „^ �r�,- SUPERIORPOOR ADEQUATE NONE 5 Roof GABLE 10 PLUMBING HIP BATH 13 FIX I GAMBREL MANSARD _ FLAT SHE TOILET RM. (2 FIX,I "�''_•'� ASPHALT SHINGLES WATER CLOSET SHINGES LAVATORY KITCHEN 51NK —” TAR 6 GRAVEL NO PI UMBING — �" ROLL FING ROOSTALL SHOWER — _• •.;,r, ;;l MODERN FIXTURES — �"�•�' TILE FLOOR L:`.. %rte,-; 11LE DADO •l:I 6 FRAMING I 11 WOOD JOIN 3 t .� HEATING -� a PIPELESS FURNArE L TIMBER BMS. 6 COL .tr'kr . FORCED HOT AIR FURN. STEEL BMS. COLS. STEAM WOOD RAFTE —_ HOT W T'R OR VAPOR — AIR CONDITIONING RADIANT H'T'G UNIT HEATERS tl 7 NO. OF ROOMS GAS OIL i 1st I3 I ELECTRIC NO HEATING L (•:; (�_ f'''•j7 - 7 I I e Ii ,t oF- t—ik-d Atm : �'•t_4,a 5� �Z� q Sv-rr L�. Cot \ czz� po..-n M�ACO�.J 20 Of O N V .139n L U0 N (�dr 17 fG�STEa� ►-� (F- SFcoc !}� Z3 moo±G. o � Z ooZ� y�►rz.o o� Id ��C FQo�...�T 7AiZ.0 0 ovo a T 198 -- w 4�D'FbT2..D ST�CJr T FORM U - LOT RELEASE FORM +�r, INSTRUCTIONS: This form is used to verify that all necessary approvals/permits from Boards and Departments having jurisdiction have been obtained. This does not relieve the applicant and/or landowner from compliance with any applicable local or state law, regulations or requirements. ****************Applicant fills out this section***************** APPLICANT: -AGVAN P• CA!-ll c L Phone 6S-:& -:56-3q LOCATION: Assessor's Map Number lO'i C Parcel la-1 Subdivision Coo C KA-r VL4 AS-2 Lot;zJ l Street SoyTN 2AbF020 St. Number ************************Official Use Only************************ RECOMMMENDATIONS OF TOWN AGENTS: �y Date Approved U Conservation Administrator Date Rejected Comments Date Approved y Town Planner Date Rejected Comments Date Approved Food Inspector-Health Date Rejected i / Date Approved �5 /�/3 Septic Inspector-Health Date Rejected Comments Te_ a) :' Public Works - sewer/water connections - driveway permit Fire Department oJl c1fl, Received by Building Inspector Date ALG 2 01 ^ i o R r►-i Town .0-�� : dover r. - � 1or dover, Mass., y ref rli( .F wit n AOR/ T E D S 1 ` BOARD OF HEALTH - Food/Kitchen PERMIT T D Septic System BUILDING INSPECTOR THIS CERTIFIES THAT.... Q.. .� �> .. .�r.......................................... Foundation has permission to erectw 0.0..AP*4,.lJPM&fbuildings on jV drvSd A0/.T/-.VAJ l•Xl.�.T! ,Ilr� 7 Rough to be occupied ash/../j1.6'I I f I'/.I. �J L.�».1.. ��... Ci.I.rlR.,�/ IiR/I�+ Chimney provided that the person accepting this permit shall in every respect conform to he terms of the application on file in Final this office, and to the provisions of the Codes and By relatin to the Inspecti ��dd��Qn truction of Buildings in the Town of North Andover. Stvjf ;;. �►/���. RR�I����'FOUNDAT�ON ONLY PLUMBING INSPECTOR REGUUTED BY PAK 114.8-. B.C. VIOLATION of the Zoning or Building Regulations Voids this Permit. Rough PERMIT EXPIRES IN 6 MOIRF __ ME PAIWg' �� (� Final < 6/?el�".`7 O ELECTRICAL INSPECTOR UNLESS CONSTRUCTION STAR�_S <>t Roug►, OR FRAME/BUILDING ar ......... ................. PERMIT f � :.. �..{� - ..,,., Service f BUILDING INSPECTOR ��� Final BATE: —, .FEE PC�'cc ����I'errllit IZe Leirec� to Occ�.ti BuildiriU 1���' py b GAS INSPECTOR la In a Conspicuous Place on the Premises — Do Not Remove Rough Display Y • p Final No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. Burner PLANNING FINAL CONSERVATION FINAL Street No. Smoke Det. SEWER/WATER FINAL DRIVEWAY ENTRY PERMIT t ... - .kry ''".�° "f-��'1t... 'a...'ri h l,r X� F�' � #I� • 3'e,4 + CERTIFIED FOUNDA TION PLAN LOCATED /N m MA. SCALE:/"_ ' DATE: Scott L. Gi/es R.L.S. 50 Deer Meadow Road North Andover,Mass. Lo-r i I 0 o � r 0 L crr t t3 tp S Nov 2 3 ' = Sou-rN �RApFoRD STR�'r / CERTIFY THAT OFFSETS SHOWN ARE FOR THE USE THE OFFSETS OF THE SU/L DING /NSPEC TOR ONLY SHOWN COMPLY AND SUCH USE/S FOR THE G WITH THE ZONING DETERMINATION OFZONING BYLAWS OF CONFORMITY OR NON-CONFORMITY _Wo. 44t�a� WHEN CONSTRUCTED. WHEN BUIL T. l o Zo 93 NOwTM, KAREN H.P.NELSON ?' °� Town Of 120 Main Street, 01845 Di' `°' ! NORTH ANDOVER (508) 682-0483 BUILDING CONSERVATION e@ "p9` DIVISION OF HEALTH PLANNING PLANNING & COMMUNITY DEVELOPMENT December 10, 1993 Mr. John P. Cahill 37 Stonington Street North Andover, MA Re: Lot #17 (565) So. Bradford Street Dear Mr. Cahill: This shall serve as notification that you may backfill the foundation at subject property taking into consideration that it has to be braced in accordance with instructions outlined in our letter dated October 29, 1993 . Yours truly, Walter Cahill , Asst Building Inspector WC:gb c/K. Nelson, Dir. PCD KAREN H.P.NELSON Town of 120 Main Stmt, 01845 DinvtffNORTH ANDOVER (508) 682-6483 BUILDING %; ;;,,::�` CONSERVATION DrvtSION OF 3 PLANNING PLANNING & COMMUNITY DEVELOPMENT October 29, 1993 John P. Cahill . 37 Stonington Street North Andover, MA Re: 565 So. Bradford Street Dear Mr. Cahill: As a result of our findings by way of an on-site inspection of Lot #17 , 565 So. Bradford Street, you are requested to submit the following: a plan approved by this Department showing the profile of the proposed slopes and construction of retaining walls behind the dwelling and, in accordance with the Zoning By- Law, calculations of the amount of fill to be removed from the site. If the profile is not sufficient, you may have to go into a topographical plan to show how you are going to alleviate the problem. After approval, it is suggested that the foundation will have to be braced before any backfilling or work on proposed slopes or retaining walls may proceed. In the best interest of public safety, it is also suggested that you secure the site in order that young children and others are prohibited from gaining entrance to the property. If you have any questions regarding this matter, do not hesitate to contact the office. Yours truly, Walter Cahill , Ass 't Building Inspector WC:gb c/K. Nelson, Dir. PCD Given in Hand on 11/01/93 signed: ' Town of North Andover BUILDING DEPARTMENT Homeowner License Exemption (Please print) DATE oto AO: 'C�3 JOB LOCATION SIoS Soy T�� �2ApFo�O S` " Number Street Address Section of town "HOMEOWNER0 Name Home Phone Work Phone PRESENT MAILING ADDRESS 3-7 sioN'<<.►��o,�L Sf . City/Town State Zip code The current exemption for "homeowners" was extended to include owner -occupied dwellings of six units or less and to allow such homeowners to engage an individual for hire who does not possess a license , provided that the owner acts as supervisor . (State Building Code , Section 109 . 1 . 1 ) DEFINITION OF HOMEOWNER: Person( s ) who owns a parcel of land on which he/she resides or intends to reside , on which there is , or is intended to be , a one to six family dwell- ing , attached or detached structures accessory to such use acid/or farm structures . A person who constructs more than one home in a two-year period shall not be considered a homeowner . Such "homeowner" shall submit to the Building Official , on a form acceptable to the Bulding Official , that he/she shall be responsible for all such work performed under the building permit . (Section 109 . 1 . 1 ) The undersigned "homeowner" assumes responsibility for compliance with the State Building Code and other applicable codes , by-laws , rules and regulations . The undersigned "homeowner" certifies that he/she understands the Town or North Andover Building Department minimum inspection procedures and recuirements and that he/she will comply with said procedures and recuirements . HC 1E01•:.;E7R ' S SIGNATURE ci N. P c, ' APPROVAL OF BUILDING OFFICIAL Nota : Three family dwellings 35 , 000 cubic feet , or larger , will be required to compiv with State Building Cude Section 127 . 0 , Construction ControL . 120 Main Street, 01845 KAREN H.P.NELSON = Town of Director (508) 682-6483 ,. NORTH ANDOVER BUILDING �,' ,0 CONSERVATION ss„""il6 DIVISION OF HEALTH PLANNING PLANNING & COMMUNITY DEVELOPMENT CHIMNEY APPLICATION .AND PERMIT PERMIT # DATE LOCATION / b l l 1 5 � OWNER' S NAME BUILDER'S NAME MASON' S NAME MASON' S ADDRESS MASON' S TELEPHONE_ 4r oo el7 MATERIAL OF CHIMNEY ; INTERIOR CHIMNEY ,./ / � EXTERIOR CHIMNEY^ � NUMBER AND SIZE OF FLUES THICKNESS OF HEARTH //p / Will chimney or fireplace conform to requirements of the code and have rules and regulations _been,_eceived: -s' 7 �. - Location—. CONTR. LIC. # tl,l,,/y r No. -r Date CE 1;07 oc MORTH TOWN OF NORTH ANDOVER ,```" FEEso F p Certificate of Occupancy $ ' ; = Building/Frame Permit Fee $ �,'°�•�° '<� Foundation Permit Fee $ Ss�cMust Other Permit Fee Sewer Connection Fee $ ---- Water Connection Fee $ ----- $ r E UIRED TOTAL �AYED ON THE PREMISES -7 \ Building inspector �I Div. Public Works JOB COLLOPY SHEET NO. / OF ENGINEERING CONSULTANTS CALCULATED BY FAI G DATE 65 Ayer Street METHUEN, MASSACHUSETTS 01844 CHECKED BY DATE (508) 685-8069 SCALE EOt]NhATION 1 . THERETAINING WALL : AND FOOTING CONSTRUCTION IS TO BE BUILT A'. S110WN CYN THE; DESIGN .DRAWINGS . NO CONCRETE SHALL �E PLACED IN !WATER OR ON FROZEN ...........:.............;...........4...........,....... _.... .... .... ..... ... ..... .. ... GROUND. ; ' ' ' ' ` 3 . ALL FINISHED EXCAVATION FORMWr_?RK AND RSIN1aOI CEMENT PLACING SHAL,L`BE I ].SECTE 8 ' CCSLLI1FYNGINEETING BEFORE N.Y -c6Nc.�ET'E.......I ....gt,.#AGED.........E. .I..L.I.R.. .....gy...... g..E...C�WN.E.�./,.0.C�NT.R.ACTC)R.... TO RRCIPEI�LI' N6TI'FY CCyLLQPY ENGINEI RING(1 2 HOUR NOTICE) ... ........ ... TO INSPECT THE ...PLACING DF .THE �ELNYd;RGEME�`NT WILL"NtjLLIFY; ANY:.RES.PC).N.S.I.D. ..L I.TY.....RY......ClbtC)P. '.....ENG IEEE R I..NG.......F.()R... T.H.E.....SAFETY COF SUCH (,C)14 )N. OjJC RETEs .......:..........:.......... ..... ..... ...... ...... ... ..... ...... ... ..... ..... ..... ...... ...... ..... ..... ...... ..... ...... l. ...... C).N ,.RE.T.E.....S .A_L_L.......14.A.�.E.......A.......M.�..N.11.M.UM......._.2-8......D.Ay 6M 'Z.5.�V..E ...5TR.ESS.,....... 9' C OF 3600 PSI .. ...... ..>.. FE)IIR FEET E3F ]3 4G— ILL WILIJ....BE AW)WED AGA INST ;THE WALL AS LONG CONCRETE HAS ADEQUATELY CURED TO 75 % OF ITS SPECIFIED STRENGTH . THIS IS ' A !MINIMUM; OR ...5..D.AYS.'UNDER NORMAL- -TMPERATtRE: CCNDTIC�NS ABC)VE �C)' DEGREES UNLESS ........OTHERWISE__..ACCC)tINTED.....FoRI BY SPECIFIC ADMIXTURES . _.. .............. ...... ...... ..... ..... ..... REI NI'ORGEi�ENT ...........................:..........._... ...... ........ ............... ...._ .........:........................ .. . ............. .................. .. . 1 . ALL: REINFORCING STEEL SHALL ; )NFORM J01 ASTMIA6i5 GRADE 0 ..ANDBH_A.L.L......R.E.. PLAC#D...:I_N...; DAGE 1TH.......THE DESIGN DRA. J.I NGS.......................e...........;............. EXPANSION & CONTROL 30INTH........... . . ....._: ... ...............................:..................... l .: WEAKENED PLANE CONTRACTION Jt)INTS SHC)II ,I> BE PROVIDED AT INTERVAL; OF `'f) FEET ANI) KEYED EXY:ANSIC>N :JC)INTS SHOULD ..: DE ,PRC?V_I.D.ED..A�'. ..EVERY.;_THI_RD CONTRACTION JOINT OR 6C) ;FEET ; ... OR AT . INTERRUPTION� WHERE THE WALL CHANGES DIREC"TION WEAKENED: PANE- ARE °MADE EITHER WITH BUITARLE 2UBLER .ST.RI.PS.....PLACED ..VERTNALLY .FULL HEIGHT IN EACH FACE .... OF THE WALK AND ; LEFT THERE OR 4 ITH WOOD STRIPS SIMILARLY PLA-CED BIIT :EVENTUALLY_ REMOVED AND THE RESULTING SLOT FLL,LEv W'1 H.....MAS.TI.Q: GALILK.Li G..;.._H()RIZQNTAL REINFORCEMENT: ... ... MUST BE 'INTEI�RUI'TED AT EXk'ANSIC)N AND CONTROL JOINTS: vnooucTsaa(slrgrStab)2os1(P&MW)®oh.crclo..Wuma1.Toaa "MTOUFRU I-Maw • I ' CAHitL SES iDE.,,c E .. JOB COLLOPY SHEET NO. OF ENGINEERING CONSULTANTS 65 Ayer Street CALCULATED BY-�NG oarE METHUEN, MASSACHUSETTS 01844 CHECKED BY DATE (508) 685-8069 SCALE �,�— 3 S T I €�t' i�,__r— )=Q F FR I P4 I f-3 #�;� i ........ .............. ................_.... . PREEkli 'fiTC)N OF s. TL............................. .... .... ...s.. ......... 1 . FOR ; PROPER PROTECTION AGAINST FROST ACTICIN, THE BOTTOM ........ ......................:. C)F .. ... . .:...... .. THE RETA;ININQ WALL FOOTING S$A)'1L BASE AN EIEVATI'ON ....._.. WH.I..C.H.... I.. .....A......:M.I.} ItIN ElE......Ft;t1.R.{.. ._ .......FE.E.T.:.....SELC�W....F..I.H..I..SHEB...CRA.DE .......................:. ON HOUSE S IDE! Ok` WALLS. z TH.E......BCT '{�M.....C�.F....FCiC)T ..NG......AN.D...OI�_!... NEA ......L.LIC....SHA.L. ,...._IE.....PLhCED....... ON UNDISTURBED_ _SOI , . ` IF SOIL I'S DISTUI BED, ADEWATE COMPACTION :SHALL' BE PROVIDED: BY PROOFROLL-ING THE; SOIL .IT.H......&......T. }.......1{1.....PASSE.. ..._{jF....... ......_l{.......T.CIN..._V B1 AT{IRY.....R.O. LUER ...T.Cj. ..... DENSIVY THE SOIL; ASD !COMPACT! IT TC) 4.5 1 OF THE MtAXI;MU� .................4............... ... , .......................__............................ . . . . . ........................................................ . t . . . ...:......... DRY; DENSITY AS DETERMINED !BY) ASTM1SPEC' D*-X557WHTGH T5 ......... H.E.....NC ESL. _I_H.D......PRf CT4IR..._TEES._:......T.H.E....BAMS.......FQR.....T.H.E....... .E.T.A..L .LNG....... ........... ..... . .... _ ......`. .... ........_WAL_L..._IJESGN.............5..._THA' A NET ALLUWABf�E BEARING CAPA "ITY C)F ......._......... . .. . ............. ... . .. .. ... ,.... O G E) PULI�IDS ER 5�1[IARE FO()............. (PSF) SAN BE A-.CH EYED.>...B. ............. .................! PRf)PEI...._CC)I�PAC_T..L.O�{.......�EGHN--i-Q-LLE.S..........T.H.E_!....G{�.LL.r...WNLG L....... S......T.C)..._g.E......................... ..... .... .. . PLA GEh C)N ..THE; HCIUSE SIDS CIF �'H WALI S1C)t1LD` BE CC)MPAC EU .. .....................................,........................ ... AS DESCRIBED ABOVEALSO 3... THE..._F_Q1NDAT_LC)N....._CONTRACTUI�...__IS: RESPONSIBLE FOt� PROVIDING .......... .... ........ ::...... .... TEMPORARY EARTH !StIPPCIRT DIIRING EXCAVAT30N. THE ENCyINEER IS �tC1T RESFt)NSI$LE FOR 4NI EtARTH CC}LLAPSE C)R StIBSEQUENT _ ....................GC I.I�.E..T.LC�N.._W.QVK....REbltTING....FROM....._St1C_H.._COLLAPSE . 4 .......THE` M�4Xi1IlM SC)IL SLOPE BEHIND SHE RETAINING: WALL SHALL, BE .. .0?N ..''.( .. FDOT.. C)�'._.VERTICAL RISE; FOR EACH TWO HORxZC)NTAL FEET) . THIS IS INKEEPING WITH .......... HE ;SITE UR IEY , DESiGhI WC)RK AND-.!" RECOMMENDED .FI A—L- GRADES BY .. ... S.O.CST.T._,..G.L ,E. ..,........ EG_ISTER_EP.I LAND! SURVEYOR., THE SOIL BEHIND .... . THE; WALL; SHOI]LD ON ,Y BE PIACED ;AFTER THE :CONCRETE HAS! F L1LY :.0;Ll.REb......AND HAS ATTAINEI) ._.THE ....DES.LG.N.....C{)MPRESSI..V.E. a.TRE.Nr.TH,.AS......CSL.V.FN......D.E_ON,..:..U.NLESS..AS...STATED OTHERWISE THE: RETAINING WALL". WAti DESIGNED T ) SUPPE)FST_ THE STAPI LOADS...,.W.H:I.0 11; .....AIDE.._T.HE.....E.E..�.tlLT.. C�F..._THE.;...SOIL! EACKEILLED. AGAINCT THE WALE AND IS! NOT t AI'ABLE pW OF WITHSTANDTNG ANY AZ)T3TTI()NAL"'LC)ADS CALKED; BY .S IDING. -CAUSED -1-1— SOIL , StIC"H A, CAUSED BY. A. S.LC)PE...S.TAB.I.LIT..Y !FA.I.LURE,...... IT T THE .RESPONSIBILITY OF THE OWNER AND HIS :SITE ;PREPARATION ��ONTRACT0R TO PREPARE...THE.....STT ...S.C) THAT--THE. EXISTING SOIL IS NC)T IN AN tl.N.ST.AZLE. C: 1NDLT.LUN ..... . PRODUCT 204.1(SM04 SIia17(205.1(PoM)4 a4kr,Gmwk Yat 0101.100tdaMW TOLL FREE IB0623,= � 9 JOB G�yi�G E 5 /DENa E COLLOPY SHEET NO. Z OF ENGINEERING CONSULTANTS CALCULATED BY �/� C DATE /2-1�419 3 65 Ayer Street METHUEN, MASSACHUSETTS 01844 CHECKED BY DATE (508) 685-8069 SCALE .... .. .... ........... ...... .. ..... . ...... mss. s,o �ift D --- - - �: E .......... : o h o ....... ...... _...... .. „ 5„ _ � . ..... ................ 4 _ ... ....... ._ .. . . l........... ... . ��I z 615 _. ll G�1.511.11. x/06 _ .... ... `s. ......-.... ...... .... ...... ..... .... li 1 _. .. ..`;.__.... ........... ...�. ...... ...:...... ................. .. ... .. .... .. ....... :. .......... _. ...... i _ t. 1 _ � ............... ... .......... .......... .. ... .. ....... .. ........... ........ ............... .. ...... _ — f .......... .... ... :_...... .._... s. ......._ ... ; .1— yr....... ......... !/ 7 T�p of __; 5- ........ _ . ...... .. �_.. ... .. G 1 ..... _. t. ... _._ .. ...�t5,5 1>✓TD7-- I 1 ..... . ..... fjvT7"0- 40.- "AA1.0 STL..... ..,....N.. '. ............... ..,. .......... .._ __... ..... .... a KL1( ETwE �� W A-L�- Fri _... _ . .... . 4457�-rT . _. . MiODUCT 2D1-1(&4k 5hxn)205-11FtMl i0 a*,G,*B,MxL C11T1.Ta fty PHgff TIX1 FREE 1-M225-M i - - CO LLO PY SHEET NO. OF. ENGINEERING CONSULTANTSCALCUTATEDBY `l 3 65 Ayer Street DATE METHUEN, MASSACHUSETTS 01844 CHECKED BY DATE (508) 685-8069 SCALE ........ _ ............. i'N'S1D'L''�i9G/C '2 // �YIAK rLL�W/�Bl f S T E _ S /j .......:.... : u E � P ...........:......... .............. ii E L . ........................................ ........... . ......... .......... . .... ............. ...... . ..... .....T,o-w _ _... . f .. : �. ..........:......• .. ..... ..... .... f. ................................................................._...................... ..... ..... ...... ..�..... �......r........... ...... ..... ...... ...... #..y� ..�.....p�� ... ora...................._................................... .... ........................................... ............................�.... ....:... ......:.... :............ .. .... .... ..... ...... ..... ..... ...... .................. .. V�aT r' ! ..........._ ....... ... ..... ...... ...... i I C ',� 2 S • � �a/ Ate• Si�- E' Y y. •r L iT t � G6C : : : ........_ .........................................................._` ..... .... .... .. ........................ ...... ..... ..... n f� (y�.....:..........:.... ...q.... ...... ..... ..... ...... ...... ..... ..... ...... ..... ...... ..... .... ..... ..... ...... ...... ..... ...... ..... 1 ...................................... .............;.........;...._....... .........'... ._:... ..... ...... ..... ..i.....;.. . ....:.... : ................. G ..............:........................... .:.. v :..... ................:..... ..... :... 6er2crg.q! 5`y .. ,. . �j............... ... 0 3=3N ... ...... ...... ..... ...... ............................................................. ...... .... .... ..... ............................ ..... ...... ...... _O L""-- i i �5� ly x7 Z^G / 2' !' ..... Tv0 i OF FCoT/NG .... , y...De.u..� .c� ky. ..�'.�..... .....y.... TaPiT `f........... f'. _i ___............ ...............•.............•..._�..._...........................1.............e i .......o . .. ..... ..... .._. ..... AS......... ..... .......... ...... ...... i ............... ....... �....._.._...... ap { ..:.. $err, 1.$ � .. x" -. . ...... ................:..........................i............................. ...... ...... .. .................. ...r... .... ... ..... .... ...... ............. ..._ ...._ ...... ..__........... .. 2dE�,.. /N. u`. 1 ...;....... _... ........ ..... / ;n opooucrza•i is�w�snNu�:osi���0®�x.c�aoa ws,.oia�.Toaaavrar�rour��aaans"uvo COLLOPY ENGINEERING CONSULTANTS 65 AYER STREET METHUEN, MA 01844 FRANCIS H.COLLOPY REG.PROFESSIONAL ENGINEER i — Residence:(508)685.7969 Office:(508)685-8069 CIVIL STRUCTURAL DYNAMICS �•� OFttq FRANCIS H. COLLOPY December 4 , 1593 20172 NA1- Mr. John Cahill 37 Stonington Street No . Andover, MA 01845 Dear Mr. Cahill : As per your request, I have prepared a structural design for a retaining wall for your residential site on Coventry Lance. , in North Andover, MA . I visited the site on November 30 and again on December 3 , 1993 for the purpose of inspecting the site and to examine the existing soil conditions , and existing contours of the hill behind the proposed residence location. I am enclosing the retaining wall/footing designs for the retaining wall location as shown on the site plan and contour map drawn by Scott Giles , Registered Land Surveyor. The foundation design is based on the proposed design contours shown thereon which assume a final slope of 1 foot vertical rise for each 2 feet of horizontal run . The design is to accommodate a difference in vertical height of the soil elevation at the wall of 8 feet. For proper frost protection, the bottom of the footing is shoran to be at 4 feet below the finished grade on the low side of the wall . The design is based on an allowable soil pressure of 2000 pounds per square foot(psf) which should be able to be attained for the soil on the site if it is properly prepared according to the specifications contained Herein . There are certain critical phases during construction which should be closely adhered to , and any soil preparation and movement should be done by competent contractors who are knowledgeable in this please of construction. �y If you have any questions in this matter, please don' t hesitate to call this office . Sincerely , COLLOPY ENGINEERING CONSULTANT"' Francis H . Coll.opy ,P . E . Structural Engineer Enclosure . 0 COLLOPY ENGINEERING CONSULTANTS 65 AYER STREET METHUEN, MA 01844 FRANCIS H.COLLOPY �• REG.PROFESSIONAL ENGINEER Residence:(508)685-7969 i ii. ' Office:(508)685-8069 CIVIL STRUCTURAL DYNAMICS December 22 , 1993 it OP hA� Mr. D. Robert N icetta FRANCICOLLOPY H. Building Inspector 20172 Town of North Andover 0 120 Main Street North Andover, MA 01845 /ordAt-���` Dear Mr. Nicetta : I am writing in regards to the residential property at the end of Coventry Lane which is owned by Mr . & Mrs . John Cahill of 37 Stonington Street, North Andover . The purpose of this letter is to provide your Office with my recommendations relative to the construction of the retaining wall and the timing of this construction relative to the framing of the residential building itself . At the end of November, I was asked by the Cahills to design a retaining wall which would hold back the earth behind their house site as per the proposed contours as developed by Mr. Scott Giles , Registered Land Surveyor. Before any designs were developed by this Office , I visited the site . Ire fact , at that time , I visited the site on two different occasions , namely on 11/30/93 and 12/3/93 . The purpose of the site visit was to inspect the relative location of the building foundation, and the hill of earth to the rear and sides of the foundation , and to review the existing contours . Subsequently , I designed a retaining wall to hold back 8 feet of earth(actually 12 feet considering the four feet for frost coverage) which was planned to be contoured behind the wall at an upward slope of 1 foot vertical rise per 2 foot horizontal , which is a slope of 26 . 6 degrees . The design package which I provided to the Cahills contained very explicit recommendations and specifications regarding the slope of the earth behind the retaining wall . I indicated that my design was to retain the static loads of "resting soil" and that the wall was not designed to resist any sliding earth mass . I explained in detail to the Cahills that the earth in its present condition(of 11/30 to 12/3) was not stable and had the potential of having a sliding failure under certain 1f Cahill/Coventry Lane Page 2 i conditions , such as when fully saturated or in the presence of running water from above making its way through the soil and developing slippage/failure planes . I pointed out the possibility of the liability involved in the conditions which I saw at that time , and told them that I had a professional obligation to so warn them, and others , that the condition should be rectified as soon as possible . Based on my experience as an expert witness in many court cases , this condition is waiting for an accident to occur and for 5 lawyers to appear on the scene, and nobody will be spared ! ! Based on my observances and my professional opinion, I make the following recommendations : 1 . To regrade the existing slopes away from the building site and to remove the precarious hills immediately adjacent to the foundation, to remove any possibility that a mudslide would move down and damage the foundation, and/or cause serious injury to anybody who might be in the area, such as playing children, etc . 2 . I suggest that some of the earth in the rear could be used to fill in the foundation as per the Giles contours . This would prevent frost damage to the existing foundation and help to alleviate the stability of the hill to the rear. Care has to be taken to offer frost protection on the interior of the foundation wall as well , of course . 3 . I suggest that prior to performing #2 above , that the foundation be properly supported to resist the lateral pressure of the backfilled soil . Any temporary supports should be kept on until the first floor is framed . 4 . I recommend that the retaining wall not be built until the spring when temperatures and other weather conditions would be more favorable . With a wall this length , I have a concern about the quality control of such construction and the possibility of cracks even though we have specified sufficient temperature steel and called for the installation of expansion and control joints along the length. The wall is approximately 150 feet in length and it is not very probable that the careful workmanship and temperature control , which is needed for the proper curing of the concrete , can be guaranteed . Construction of this type during the winter months is asking for trouble , in my opinion . r' Cahill/Coventry Lane Page 3 b 5 . I would think that for the sake of progress , the construction on the house could proceed as long as the hill of earth is pulled far enough back and that safe slopes are developed and maintained until the spring . This would allow the owners to begin to frame the building and make some progress during the winter months . It would be the responsibility of the owners and their earthwork contractor to properly move the earth and to develop safe slopes away from the building. I revisited the site yesterday, December 21 , and observed that some grading had been performed and that some of the immediate earth fill had been used to grade the land level behind the building foundation. I also observed that the precipitous "hill" had been moved back in the rear of the house . The earth on the left side of the building is still fairly close to the foundation and the slope appears to be greater than 45 degrees . It was raining and no work was going on, but I understand that the regrading in this area is in the process of being completed If there any questions regarding these matters , please don't hesitate to contact this office . Sincerely , COLLOPY ENGINEERING CONSULTANTS Francis H . Collopy, P. E . Structural Engineer cc : Mr & Mrs . John Cahill C1. 2 Yy i � I F'o2 a 4-1 L—A A C.�GAI 1" Zo' Uov 22 l4gb S�v-r-r�. G«,5 Qi•L..S. s. P 4"vE� Hour S c7.G. Go..�!E Q TH� JLta � �r�H�LJ D TV-1 fG �dP• TZ�c7T- �!AL.� (LAv E� { . G�- = 2 Z So�•G.7'. S C0 4- / Prrop sm 6 - - a Z :o F 238 . F"•G. 20$.0 232 � 2-30 Zx.s(� • � a ;q 222 To�►J. 2o$.O i i � � 220 2� i �'t�. �i 1G S •, 214 •- ,' � o �` ,��-_ 21.2 � • � z � � � i ` 39•S 2ao.5 FF` t4 ,4 2g� \ \ 148 �`• �\ � ` \` 19 20 a,Q a\ GZJE�E:�1 5 ' + NOV 2 1 c, R '! M - CP-H-0--N-E--C ALL. �e� A.M. FOR DATE TIME P.M. M OF RETLtRNEO PHONE ova Yf7Ltt GALL AREA C E NU E EXTENS N PLEASE CALL. i MESSAG W LL GALL> :AGAIN 77 CAME TO': SEE YOU' 1/V;4CVT51'Q SEE YOU' SIGNED TOPS " FORM4003 PHONE CALL) A.M. FOR DATE TIME P.M. M PHONED OF PHONE 0D AREA CODE NUMBER EXTENSION ' Lt- MESSAGE LMESSAGE !i ASE CA WILL CALL AGAIN, ` GAfl1tE TO;: WAN79,7G1' SEE�Y.QU'; % SIGNED TOPS FORM 4003 rF r� �� � �_ 4 - �� l ��=���'� O N stew���� �� ? l�� ��• R�•t���� fNARON '7HMsAvenue Concord,NH 03301-4803 Tel. 225-0007 ENGINEERING FAX(603)225-0099 INC. October 31, 1994 NOV - 419M Mr. Jack Cahill 37 Stonington Street N. Andover, MA 01810 RE: Recommendations for Segmental Retaining Wall (SRW), Lot 17,Bradford St.,No. Andover, MA Dear Mr. Cahill: The design recommendations contained in this report have been produced at the request of Gilbert Block Co., Laconia,NH, and relate to a segmental retaining wall (modular block) proposed for the above noted location. Project Information: Based on limited information supplied to us(and the attached sketch), it is our understanding that the proposed wall will consist of standard Allan Block concrete masonry units (as manufactured by Allan Block Corp, Edina, MN), and erected in accordance with the Allan Block Retaining Wall System, as described in their Design Manual, and described in the Specifications attached to this report. The wall is assumed to have an exposed height of no greater than 6.0 feet throughout its length, a near-level backfill at the top/rear of the wall (extending a minimum of 15 feet rearward), before sloping upward. There will be no surcharge weight on the level backfill at the top/rear of the wall. The grade at the front of the wall is also assumed to be near-level for a distance of at least twice the height of the wall. No geotechnical borings or specific soils information have been supplied to us. We have, therefore, assumed that the foundation and retained soils (on site) consists of a silty clay soil, with an internal friction angle (phi) of 28 degrees, a net allowable soils bearing capacity of between 2000 PSF and 2500 PSF, and a maximum unit weight (moist) of 125 PCF. Design Recommendations: Based on the information noted above, we are recommending that the soil mass retained behind the wall be reinforced with a Fortrac"3 5/20-20" Geotextile Geogrid (as manufactured by Huesker, Inc., Charlotte, NC), installed in strict accordance with the manufacturer's recommendations, and specifications for the Allan Block Retaining Wall System. The number of layers of geogrid, height of each layer(above the base) and width of each geogrid layer (measured from the rear face of wall) are as recommended in Table 1 following: CIVIL,HIGHWAY,STRUCTURAL ENGINEERING AND SURVEYING Page 2 No. Andover Retaining Wall October 31, 1994 TABLE 1 Height Above Base Geogrid Layer# (feet/block courses) Geogrid Width 1 1.33'/2 3)- 015 2 3.33'/5 41- 011 3 5.33'/8 57- 011 The Geogrid shall be backfilled along its entire width with a free draining sand or sandy-gravel (i.e. "bank run" gravel)with no more than 5% (by weight) passing a#200 sieve (or as specified in the Commonwealth of Massachusetts Dept. of Public Works"Standard Specifications for Highways&Bridges", material M1.04.0 Type a, Sand Borrow). The material shall be placed in lifts of no greater than 8 inches, and compacted to not less than 95% of maximum dry density of the material as determined by Standard AASHTO Test Designation T99 Compaction Test Method C at optimum moisture content. (Alternative: ASTM Test Procedure D1557, Standard Proctor) The material directly behind the wall, extending rearward for a width of 12" and the infill for the block cores shall consist of a free draining granular material, 3/8"-3/4" crushed stone, equivalent to a crushed stone as specified by the Massachusetts DPW, "Standard Specifications" material M2.01.4. The footing (lowest course of block) shall be buried 0.67 feet below finished grade at the face of ;wall. The soil beneath the base course of block shall be excavated 6 inches deep and 24 inches wide, and backfilled with a crushed stone material equivalent to M2.01.04, as defined above, and compacted to 95% relative density(AASHTO T99 or ASTM D1557). --�j cA Geotechnical Engineer shall be retained by the Contractof-to observe placement and compaction of the fill material and placement of the geogrid and submit a report from a certified testing agency, indicating (1) sieve analysis of each granular backfill material used on site (i.e. infill material, drainage stone, base stone), and(2) compaction test results according to AASHTO T99 or ASTM D1557, taken at the height of the geogrid layers, and at 50 ft. - 100 ft. intervals (along the wall). Reports shall be submitted to the Engineer. A perforated 4" under-drain pipe (PVC) shall be placed behind the wall, within the drainage stone, at the level of the ground at the face of the wall, daylighting at either end of the wall, and at 50' intervals along the length of wall, via weep holes. IV c Page 3 No. Andover Retaining Wall October 31, 1994 General Recommendations: The contractor must comply with the latest OSHA regulations relating to the trench and slope excavations and safety, and general construction site safety. Caron Engineering assumes no responsibility for construction site safety. The recommendations supplied in this report-are-based on limited information supplied to us, and represent our professional opinion based on currently accepted engineering practice. If conditions are encountered, materials used, or methods employed other than what we have assumed or stated herein, Caron Engineering should be notified immediately and allowed to review its design recommendations. Any questions should be directed to Caron Engineering Inc. The specifications attached to this report and incorporated by reference, shall be strictly adhered to. Sincerely, CARON ENGINEERING, INC. N OF o DAN EL X LE E U ft 3140 GML J. Levine, PE (Mass. P.E. #31403) Vice President Enclosures cc: Gilbert Block/Laconia, NH Y A94wp\94417\proj info.doc SPECIFICATIONS r }, ALLAN BLOCK '. PART 1 GENERAL and fooling dimensions shown on construction drawings, 1.1 Scope or as directed by the site Engineer. Work Includes furnishing and Installing modular concrete block 2. Foundation soil shall be examined by the Engineer to retaining wall units to the lines and grades designated on the Insure that the actual foundation soil strength meets or construction drawings and as specified herein. exceeds assumed design strength.Soli not meeting the 1.2 Applicable Sections of Related Work required strength shall be removed and replaced with A.Geogrid Wail Reinforcement acceptable material. B.Masonry Wail Reinforcement C. Base 1.3 Reference Standards 1. Base material shall be placed as shown on construction A. ASTM C90-75(1981 rev)Hollow Load Bearing Masonry drawing with a minimum thickness of six Inches.Top of Units base shall be located to allow bottom wall units to be B. ASTM C140-75(1981 rev)Sampling and Testing buried to proper depths as per wall heights and Concrete Masonry Units specifications. C. ASTM 0145-75(1981 rev)Solid Load Bearing Concrete 2. Base materials shall be Installed on undisturbed,native Masonry Units soils or suitable replacement fills compacted to 95%of 1.4 Delivery,Storage,and Handling standard proctor. A. Contractor shall check the materials upon delivery to 3. Base materials shall be compacted to provide.a level hard assure proper material has been received. surface on which to place first course of units.Compaction B. Contractor shall prevent excessive mud,wel cement,and shall be with a mechanical plate compactor to 95%of like material which may affix themselves,from coming In standard proctor. contact with the materials. 4. Base materials shall be to the depth and width shown. Contractor may opt for replacing lop three inches of base C. Contractor shall protect the materials from damage.Dam with an unreinlorced concrete lopping.When masonry aged material shall not be Incorporated Into Ilse project. reinforcement technique Is used,check looting design in PART 2 RETAINING WALL that section for further details. 2.1 Materials D. Unit Installation 1. First course of concrete wall units shall be placed on the A.Concrete Units prepared base with the raised lip facing out and the front 1. Masonry units shall be Allan Block Retaining Wall units as edges light together.The units shall be checked for level and produced by Licensed Manufacturer. alignment as they are placed. ' 2. Concrete wall units shall have minimum 28 day compressive 2. insure that units are in full contact with base.Proper care strength of 3,000 psi In accordance with ASTM C-90.The shall be taken to develop straight lines and smooth curves on concrete shall have adequate freeze-thaw protection with an base course as per wall layout. average absorption rate of five percent. 3. All cavities in and around the base row shall be filled with 3. Exterior dimensions shall be uniform and consistent. "base material"and compacted.Backfill front and back of Maximum dimensional deviations shall be one-half Inch entire base row to firmly tock in place.Check again for level (not Including textured lace).Units are required 10 have an and alignment.All excess material shall be swept from tops of. average facial area of.75 sq..It. units. 4. Retaining wall units shall provide a minimum of 100 pounds 4. Install next course of wall units on lop of base row. total weight per square loot of wall face area.FIII contained Position blocks to be offset from seams of blocks below. within the units may be considered 80%effective weight. Perfect"running bond"Is not essential,but a three-Inch 5. Exterior face shall be textured.Color as specified by average minimum oflsel is recommended.Check each owner. block for proper alignment and level.Fill all cavities B. Base Material In and to an 8'depth behind block with"drainage.fill" 1. Base material shall consist of compacted sands,gravel,or Backfill remaining space behind second course with concrete as shown In the construction drawings.A onalte soils and compact to 95%of standard proctor. minimum of six Inches of compacted base is required. 5. Lay up each subsequent course In like manner.Repeat C. Drainage FIII procedure to the extent of wall height. 1. FIII material for unit cores and for drainage behind well 2.3 Water Management shall consist of tree-draining,granular material.Gradation A. Avoid retaining wall design and Installation which would peril shall Include material to 318 Inch minus with lines limited to pooling and collection of surface runoff above wail. 5%passing If 200 sieve and less than 50%passing 940 B. Adequate provisions to.be made to control surface runoff and sieve. direct around wall ends.Provide swales above and below wall 2. A minimum of 8 Inches of drainage fill must extend behind as permissible to accommodate. the wall to within one tool of the final grade.Cap backfill C. Retaining Well design and Installation to provide maximum with Impervious material. lateral drainage at site as allowed by existing site conditions. E.Backfill D. Provide for additional drainage relief behind retaining walla 1. Material shall be native material unless otherwise specified above 5 feel in height.Install 4-Inch diameter perforated drain in the drawings.When using geogrid for slope reinforcement, tile at wall base and above grade at base of wall.Install tee- soils used to backlill geogrid must comply with standards fittings and outlets through wall surface at no greater than 20 set by grid manufacturer's guidelines. feet on center. 2. Where additional fill is required,contractor shall submit E. Provide for adequate mulch or vegetative ground cover above sample and specifications to the Engineer for approval. and surrounding retaining wall to prevent excessive soil 2.2 Retaining Wall Installation erosion. A. Excavation F. Contain sources of concentrated water flow such as root 1. Contractor shall excavate to Ilia lines and grades shown scuppers,drains and valleys,parking lots,etc...and route on the construction drawings.Contractor shall use caution around wall accordingly. not to over excavate beyond the lines shown,or to disturb the base elevations beyond those shown. B. Foundation Soil Preparation 1. Foundation soil shall be excavated as required for base SPECIFICATIONS . . REINFORCEMENT GEOGRIID PART 1 GENERAL D. Geogrid shall be laid at the proper elevation and orientation 1.1 Scope as shown on the construction drawings or as directed by the Work Includes furnishing and Installing geogrid reinforcement, Engineer. wall fill,and backlill to(lie lines and grades designated on Ilia E. Correct orientation(roll direction)of the geogrid shall be construction drawings and as specified herein.Also Included verified by the contractor. Is the furnishing and installing all appurtenant materials re- F. Follow manufacturers guidelines relative to overlap require- required for construction of Ilia geogrid reinforced soil retaining ments of unlaxlal and biaxial grids. wall as shown on the construction drawings. G. Location and placement of the geogrid Is as shown on the 1.2 Applicable Sections of Related Work drawings.The relative position of the geogrid layers to the A. Section I:Allan Block Modular Retaining Wall Units. height above finished grade must be maintained regardless. 1.3 Reference Standards of the number of units which ere placed below finished A. See specific geogrid manufacturers reference standards. grade. 1.4 Delivery,Storage,and Handling 3.4 Fill Placement and Backfill Placement A. Geogrid A. Wall fill material shall be placed in lifts and compacted as i. Contractor shall check the geogrid upon delivery to assure specified under Section:Modular Concrete Retaining Wall that the proper material has been received. Systems. 2. Geogrid shall be stored above-20 degrees F. B. Backlill shall be placed,spread,and compacted In such a 3. Contractor shall prevent excessive mud,wet cement, manner that minimizes the development of wrinkles In and/or epoxy and like materials which may affix themselves to movement of the geogrid. the gridwork,from coming in contact with the geogrid C. Only hand-operated compaction equipment shall be allowed material. within 3 feet of the wall face. 4. Rolled geogrid material may be laid flat or stood on end D. Backlill shall be placed from the wail rearward to insure that for storage. the geogrid remains taut. PART 1 GRID MATERIALS E. Tracked construction equipment shall not be operated 2.1 Definitions directly on the geogrid.Minimum backfill thickness of 6 A. Geogrid products shall be of high density polyethylene or Inches Is required prlor to operation of tracked vehicles over Polyester yarns encapsulated in protective coating the geogrid.Turning of tracked Vehicles should be kept to a specifically fabricated for use as a soil reinforcement minimum to prevent tracks form displacing the fill and material. damaging the geogrid. B. Concrete retaining wall units are as detailed on the drawings F. Rubber-Ilred equipment may pass,over the geogrid re- and are specified under section:Retalning Wall Units. inforcemenl at slow speeds,lose than 10 MPH.Sudden 2 C. Wall fill Is a free draining granular material as dellned In braking and sharp fuming shall be avoided. section:Modular Concrete Retaining Weil systems as G. The backfill shall be compacted to achieve 95%standard 1 "Drainage Fill"behind the wall. proctor.Sol[tests of the backfill material shell be submitted to D. Backfill Is the soil which Is used as fill for ilia reinforced soil the on-site engineer for review and approval prior to place- mass. ment of any backfill These soil tests shall be performed by E. Foundation soil is the insititu soil. an independent testing agency,or approved on-site lab. 2.2 Products The lest results shall be given to the on-site engineer as A. Geogrid shall be the type as shown on the drawings having soon as possible after testing.The contractor Is fully respons- the property requirements as described within Ilia Ible for achieving the specified compaction requirements. manufacturers specifications. The on-site engineer may direct the contractor to remove and 2.3 Acceptable Manufacturers correctly replace any soil found to be not In compliance with A. A manufacturers product shall be approved by Ilia engineer these specifications. prior to bid opening. PART 3 EXECUTION MASONRY 3.1 Foundation Soil Preparation A. Foundation soil shall be excavated to the lines and grades The design and construction of a Reinforced Masonry Wall System as shown on the construction drawings or as directed by the shall comply with Sections B through D and the provisions of Engineer, chapters 23 and 24 of the 1991 UBC. B. Foundation soil shall be examined by the Engineer to assure that the actual loundallon soil strength meets or exceeds assumed designstrength.th. TECHNICAL SUPPORT C. Over-excavated areas shall be filled with approved compacted Engineering support for projects that fall beyond the scope of , backfill material. these guidelines,contact ALLAN BLOCK CORPORATION at D. Foundation soil shall be proof rolled prior to fill and geogrid 1-8001899-5309 for assistance. placement. 3.2 Wall Erection A. Wall erection shall be as specified under Section I:Retaining Wails. 3.3 Geogrid Installation A. install ALLAN BLOCK wall to designated height of first grid layer,backlill and compact behind wall to depth equal to designed grid length. B. Cut geogrid to designed embedment length(Lgrid)and lay behind wall with cut edge of grid on lop of ALLAN BLOCK to back edge of lip.Extend to back of slope. C. Place next course of ALLAN BLOCK on top of grid and fill block cores with drainage fill to lock in place.Remove slack In grid and stake to maintain tension. ,��. 4"vE.�x' --. F t.' -rNr� �7C_o Pry l".r �.;• Via \ ell t-9 2"x-- 2,44 -- - -- --- 2 ale Z4, G y 232 Z?�i - " l4 \ - t4 2,vo 212 •... .-- � n , 19fd ` � �� \' + �'g i�/ �/ \ - -__--.�---�c�.- -��•'v`l� . • - ' - =ice"'2'-" '.\ - \ `. A-1 IQ 1 7.171 n ` CARON ENGINEERING, INC. 112"If"UM12 Consulting Engineers, Civil & Structural r' 7 Hills Avenue CONCORD, NEW HAMPSHIRE 03301-4804 DATE' �r P,V\ (/J10?0� (603) 225.0007 ATTENT� 0 FAX (603) 225-0099 TO RE: MA wlu� I WE ARE SENDING YOU Attached ❑ Under separate cover via the following items: ❑ Shop drawings ❑ Prints ❑ Plans ❑ Samples ❑ Specifications ❑ Copy of letter ❑ Change order iox3 COPIES DATE NO. DESCRIPTION Li THESE ARE TRANSMITTED as checked below: ❑ For approval ❑ Approved as submitted ❑ Resubmit copies for approval 114 For your use ❑ Approved as noted ❑ Submit copies for distribution �As requested ❑ Returned for corrections ❑ Return corrected prints �Eor review and comment ❑ ❑ FORBIDS DUE 9 19 11 PRINTS RETURNED AFTER LON TO US REMARKS U ")L a Cry t-'s-I trt..�S J rl, U r �Y 1 . Nft--,V.A%.s �ajc-t�s4=D lo�_ COPY TO —^� �J RECYCLED PAPER: SIGNED: ��1 C _ Contents:40%Pre-Consumer•10%Post-Consumer If enclosures are not as noted,kindly notify us at once. QUESTIONS & ANSWERS ALLAN BLOCK ENGINEERING RETAINING WALLS • How strong Is an ALLAN BLOCK wall? Allan Block walls can be adapted to meet the structural requirements of any retaining wall site. Walls up to five feet can typically be installed without any reinforcement. Taller walls can be strengthened using conventional masonry techniques or the geogrid reinforced earth method. Site and soil conditions determine the maximum height on any specific project. • How high up can you go? Unreinforced Allan Block walls can be built up to 6 feet high in sandy soils and up to 4 feet in clay soils. Masonry reinforcement works well for walls up to 15 feet high and geogrid re- inforcement can handle walls in excess of 30 feet high. Always consult a qualified engineer on jobs of this scale. • How can I tell If reinforcement is needed? Open the Design Manual to the Gravity Wall page. The chart on the bottom of that page lists the maximum wall heights for unreinforced Allan Block walls. Match your site and soil conditions to those in the chart. If your wall height is greater than the number in the charts you need reinforcement. • How much reinforcement will I need? The amount of reinforcement needed in any project will depend on site and soil conditions and the height of-the wall. The Design Manual has pre-engineered solutions for walls up to 16 feet high for 3 soil conditions and 3 different site conditions. Match the conditions at your project to one of these tables to find approximate reinforcemen-t-requirements. • Do I need an Engineer? Generally we recommend the use of a licensed engineer on projects with taller walls or unusual site conditions. Local building codes may require the use of a licensed engineer for walls above a certain height. Our design charts and tables provide generalized engineering solutions. Each retaining wall site is unique, however, and specific evaluation will provide the most accurate solution. • Who should I call? ALLAN BLOCK CORPORATION provides an on-line engineering service for preliminary engineering on specific projects. Call 1-800-899-5309, or fax the project details including wall heights, site and soil conditions to 612-835-0013. We can provide a preliminary solu- tion free of charge. For final plans and specifications you should contact a local authorized Allan Block Engineer. NOV 1 0 1994 ALLAN BLOCK WALLS ARE ENGINEERED TO LAST! QUESTIONS & ANSWERS ALLAN BLOCK DESIGN RETAINING WALLS • Why three block shapes? Many wall systems try to get by with only one block shape, only to limit design possiblities and finished detail. ALLAN BLOCK's three shapes allow any design or wall configura- tion and every wall can have a truly finished appearance. Curves, comers, angles, steps, and beautiful straight walls–,all the options with ALLAN BLOCK. • What about caps? The raised lip on the top row of every ALLAN BLOCK wall makes an excellent edge to finish to and makes cap blocks unnecessary. By leaving the top blocks partially unfilled, decorative rock or wood mulch can be placed right up to the edge. By filling the top row with planting soil, flowers, ground cover, shrubs or turf can be planted up to the front for a soft green look. If a capped appearance is preferred, matching CAPSTONES can be placed on the top row and attached with a contruction adhesive. • Are curved walls hard to build? Actually, curved walls are just as easy to construct as straight walls. Because there are no pins to align and fit, each row simply adjusts to meet the curve. Design the ends of outside curved walls to wrap into the hill—no cutting or fitting needed. Design the ends of inside curved walls to step down and use corner blocks to finish off each row. • What about color and finish? ALLAN BLOCK is manufactured with a rock face finish for a natural, stone-like quality. Each producer selects one or two "standard"colors to inventory with the natural grey. Special colors can be ordered for an extra charge. Just ask your Dealer for details. • Can you do steps? Just about any type of step arrangement can be designed with ALLAN BLOCK. Stairs built parallel to the.wall face 'follow" the natural 1-1/2 inch set-back of the wall. Stairs built perpendicular to the wall face will widen by 3 inches per step (to account for the set-back on each side wall) as you go up. Design these stairs with intermediate landings to keep stair widths consistent. ALL THE OPTIONS WITH ALLAN BLOCK i QUESTIONS & ANSWERS wr ALLAN BLOCK GEOGRID RETAINING WALLS • What are "Geogrids?" Geogrids are flexible, synthetic meshes which are manufactured specifically for slope stab!- lization and earth retention. These "Grids"are available in a variety of materials, sizes, and strengths. They can be made of high tensile strength plastics or woven, coated polyester yarns. They are typically packaged at the factory in large rolls (10 to 15 feet wide, 2 to 3 feet in diameter, and about 100 feet long). • How do Grids work? As the wall is being built, layers of geogrid are placed at specific heights. These layers of grid run the entire length of the wall and extend to certain lengths behind the wall. The soil is compacted around the grid layers, and the friction that develops interlocks the soil and grid. The layers tie the soil together to create a solid soil mass behind the wall which resists over- turning and sliding. In a way, the grid becomes the structure and the wall becomes a facing. i • How do Grids differ? Grid types vary in many ways. Some grids are made of woven polyester strands coated with plastic. These grids are very flexible, easy to cut and handle. Some concern has been noted over their long-term durability. Some grids are made of extruded, high-tensile plastic. They are stiffer and hard to cut but seem to provide better durability. Some grids are bi- axial—the strength of the strands is equal in both directions. Most grids are uni-axial, the strength of the strands along the roll direction is greater than that of the cross strands. All grids are rated for their strength—their ability to resist deformation (stretching or creep). This strength is rated by the Long-Term-Allowable-Design-Load (LTADL) with values ranging from 500 to 3,000 pounds per linear foot. • How much Grid do I need? To determine the amount of grid for a specific project, you need to know the wall heights, site and soil conditions, and the strength of the grid you will use. Each of these factors can be combined to calculate the number of layers of grid and the length of each layer. The layers are typically spaced 2 to 3 feet apart. The length of the grid--called embedment length--can be as short as 3 feet of in excess of 15 feet. Check the Grid charts in the Design Manual for examples. • How does the Grid connect to the block? Our research and testing has proven that the friction between the grid, the concrete and the granular fill in the block pockets provides more than adequate pull-out resistance. In fact, the pull-out resistance for Allan Block is higher than that of solid concrete and pin-con- nected systems. Cast a fishing lure down a concrete driveway and reel it in. Then cast that same lure down a gravel drive and notice the difference when you reel in. That describes the superior pull-out resistance of a core-filled Allan Block wall. s QUESTIONS & ANSWERS ALLAN BLOCK INSTALLATION RETAINING WALLS • Is compaction necessary? Yes! If you try to build a wall on an unstable base, your wall will settle. Always begin by compacting the wall base. If you try to backfill without compacting as each row is installed, pockets will develop behind the wall which will collect additional water. Uneven settling behind the wall will affect drainage patterns at the surface and create other problems as well. • How much base row should I bury? As a rule, you should bury at least 1 inch of block for every foot of wall height. If there is a slope below the wall or a soft, wet soil condition, you should bury additional blocks to accommodate. • What if the base is on sloped ground? Try to start each wall at the lowest point and work up. It is better to step up the base row than to step down. Install the base row as far as you can until you need to step up. Go back to the starting point and start the second row until it hits the grade and becomes the base row. • Do I need to stack in "Running Bond?" Nol "Running bond" refers to a pattern where the seam between any two blocks falls exactly on the center of the block below. Perfect running bond is not essential for ALLAN BLOCK walls. We do recommend a minimum average offset of 3 inches or more. You can insert half blocks as needed to help maintain some staggering., • Can I cut blocks? ALLAN BLOCKS are just about as easy to cut as timbers—if you have the right tools. We recommend a masonry cut-off saw with a diamond tipped blade. These saws operate just like chain saws and the blades last. You can cut blocks using a masonry blade in a skill saw and a chisel. Score the block with a shallow cut on the front and back and snap in two with light blows on the chisel. The break will be a little rougher but you can still get a good fit. • Can the rock face fit to the smooth lip? There will be some minor irregularity between the coarser rock face and the smooth inside edge of the locking lip as each row is stacked. This does not affect either the structure or appearance of the finished wall. ALLAN BLOCK was designed not to be a precision con- struction product, but a simple, flexible, easy to handle landscape wall system. Take ad- vantage of that simplicity to get maximum production and profits,on every installation. ALLAN BLOCK WALLS MEAN HIGH QUALITY, PRODUCTION, AND PROFIT • Q UESrIOMS &- ANSWERS ALLAN BLOCK VALUE RETAINING WALLS • Will ALLAN BLOCK outlast treated wood? Yes! Treated timber walls typically last about fifteen years or less! ALLAN BLOCK's high strength concrete composition won't rot or decay. There are many examples of masonry construction in your neighborhood built 30, 40, even 50 years ago and still standing. And ALLAN BLOCKS are made three times stronger than standard concrete blocks to provide maximum durability. • Is ALLAN BLOCK more costly than wood? No! When you compare the total cost of treated timbers (including spikes and nails, buried tie-backs, and wasted pieces) to the cost of ALLAN BLOCK, the price per square foot of wall material is comparable. And ALLAN BLOCK walls can be built with fewer skilled crew people, making installation costs lower. • Are heavy concrete systems stronger? No! Tests have proven that ALLAN BLOCK can retain soil as well as heavy, bulky con- crete systems. In fact, when the ALLAN BLOCK cores are filled at the site, they develop the same weight as heavier systems. And the 12 degree set-back on an ALLAN BLOCK wall provides greater leverage and soil resistance than heavy, more vertical systems, and reduces the amount of retained soil. • Is ALLAN BLOCK expensive? Material costs for ALLAN BLOCK are comparable to treated wood, and less than lannon stone, boulders, and other stackable masonry systems. The 12 degree set-back of an ALLAN BLOCK wall means less reinforcement is needed compared to more vertical walls. Lower block costs and lower reinforcement costs. Because ALLAN BLOCK is so easy to handle and install, it is the most cost effective retaining wall system available. And remem- ber, there is nothing cheap about a rotten wooden retaining wall except its looks. • What does ALLAN :BLOCK cost? The price of ALLAN BLOCK will vary somewhat. In general, the material price for contrac- tors averages about $3.50 per square foot. Installed prices vary acco(ding to site and soil conditions, wall heights, and reinforcement requirements. Prices typically range from $9.50 to $16.00 per square foot installed. ALLAN -BLOCK IS YOUR BEST RETAINING WALL INVESTMENT )a� 1 ) r ia. 1 ay t. it1 '+(+e�st dfY-0j;•y�i J.�1 t•:.� :Jr,CS . ,Yrr e . 7, tt ? ,f )7 i;tr 77-7 Jx':Ti} 'i r5 {,�i•�J_71r. !t :Y7 ;`R.(itl {f .r{'F•4 .+ q r• , '• �.�a i!• "',r r �' `l.'{•�,r rll� '� r�''S'•�,v,.�t,py.M1 i" r!',7tY', �.�1'tA: S; '-'I/{•. 15 rir t'J�,!�{r)rl:{jt.�:'t�r7 `•� 7! �4 '{� }!f/ t✓; }r' .s 4i<.;Irtrf' ���'�}9+�sll•i'�,y�;) {i�{, fir' r�i!� �'}, � .1 r'/'1;��" �csr,` r` r;r•Yl1h�+v,' �t ;i'1;- l {i `"; Y�.rW }� 6� FITk�Lf..t�13� �r•�d lr�: Qj �{, r .t] f: , t.r. :%i'.:i•. \ ,fit�j <r:.� t.'1.;. i �. ,-r r I,. •�'FY/�' 't '+ } Y{i�• 51 �l•, l•tr .�h 5!ic, !7} jc'�% ar .r \1 r�..,l :�' •t' 0•'rj+t:�. t �'• r1 �•'•� \ r r 'r,.;�f j f1?;; ��}} qq U�9 >t )1, }f !i 1 + :�• w r t•'• !V>'••{., t}z 5 -P7 7 C 'it� r/'lljr+fyll. �t•....•/Y'.{il !' ••L` t� � 1 1 1 ` •Y.r,', • lt;,.17,jltt) yi)) ��'�`.:,, u \7.r l�t!11rdr t F�.J rJ i� j',r`,r V t =";r. x 51`'0{ /tF"t•'��rtiJ �f,�b,, •i, 1 r, r .+i �c�. [ •'li,r,,)!,�A�M, 1����`�.j)� �i ��b,�.St'EJ �a"•n� "r � :''ft7i\ir1';ir+ l��>�r'':1�y"f��t•{11 t k i !� .,7' � +t,r F ti.r _ t� �. vvj f t�u7r •r�l6(r7• ''�p�/��t��i<,1`br•'l�;`ir':S1 7t /�,ira{t'l.ft1J ,)f t ' r ^�1 , }... �V 7" `�" �►� t 7/1 7'af., ,4;�t�i7 r" t t�?+li 'Li�jJ Jrrt.rt {�'1�:}'f• ''1 ;�4 r�•� V T) 7r SJf 7'r r r tt, r .f ', ;r l; � ;ftY'?✓, { ��Yr.L ./il.�, { �V ,i �f � t, •t� + 7A 2, it Y,�}, 10;f 1 t f\*, r'.' , .. ... ., v'. r �'\�f!$j`.t.3FnA;•5{n}'�"�`r (.° 4' �r}'e!;•; a t t i>.J`�.' "(.l. cYjS ){' r iC th'•'Irf 5{�:•,'•j,.,'i'1'if�r4{S 7 .� /; ' •++.1. ` �jib pl�. 77 ti•t/�1.`t t..fi;1�r{ir Q�ij`•,{r.rkr.:i ti{�{F Iy' f �ii t�.Y��.F�i"��.1\`f r1 !+'J�t t's�, :ty,7 i. r•Mr, 't l�J,�,l.t �'t 5 L 5 ��r�4`.1Y!I ' ty7.��y�' ,�.Y„��.i�i•I r(S�t'.�1,!YA t �.j„ �j�r t�'4"�,T;�;�� -�lin.,+:, I 5 ;'1,{r 1(} ): ,.' t'C .,•t ,.;:\ F t( S t�ij,., ,� `/!�'}j •Fry 7gyi'y5 , kil/ tnJ(�(-tF7.�", ri��,�15`,,y iii �i��P, 1?5'Nt1 (.7r `r, ,It. �.ti•� 4: �, .7p}. a •f, l nS#a! tint 1•(zr..I7•�''l�if�17 , r !•�� t 7fi,'�1h ?y !i�,(G. .{^.tt!",}�n;i�D ./r•ii�2' `� (��z � ; , vrle Y;r rJf lfr` , f Y, fi 7.L4 sa S} v r r s J r; s4 h u l ll 't { , (,�1 s '''rA r.i `),• �i , ,� jr;��.'; ; r;•r[ r�� 7 � ,r Si �` {1 �'1,sr a! �a• i 5 {J•1'• •` ti t +; ° f `7 ' { i , . ��i�� r ;�,r���f���,rf �t '!'�� ���{�l�i�,/)pt'tti,.+���.c �+.,r to`� i ( r,, i W�� �r r 1'• ��` ,.J �����lf•;±w ;,7;11r�!�1������1������rt r'>'y`�t.�gr�•tt .4' ,r c 1 -`.t��j� ,"1 ';f t�} Il• �r "�'l t(r� �, ���' Y ll1 y{�'ill trP '! +i" r� *"°, ra�P�t p4��+6 F 8 'i 7ri1J) p 1 4 .7 a F• i' ;..t L 57<� ' y 4v+ , .f 'I,'i LL 'S• t If � vV/r,��:' 1 "'t 1r7:•, r r ..J t�.} � 1 5i1rA} �'rl }'.1. i•t 1y r ��#t7''+i•. ro'`"�•rw a t `�Nr , 00 X"'l�'} .Z{ r?i r. (t t �y/,i✓'I� •SF *Cr'155�i �V`r.7.�•J! tri•'•�,�fJ4+J '�t{t�s_M.,"`1.2g�� '�`r7 S:'vwNs� +�''r :r!`,r i�5 i{�1 g +I [ �.: 3. !';• Ir l..t} 7 tN ♦ ,�♦ f 1 � � t'M1l.',..1�At"�5,�,+. j t J1; f i.�rtti'1 f ,yf t,�rt �' �,t/3,'Ca %' 'S + . r!t f .c {fiti. �ly;t ,1 t t� ,i,Clr7e`1,5 "`'�i'�i.,,��',e'r:a�l,�;� � , �} •i• i�, ( +1 l .`• 1 Y'. �. 1 v':• � t �1•�\ :� r �1 '' I J.-t'• � l\ �s•'"�:Y K. �r 'w?:+`� p �f r Nt 'l: ,+:t gt i t .f� t �t > !� x ^w � { a• t(�51�\'� X i�,! t :L��f t[,t�+'w."'yac '"", +� '` { :+a � ,. { S:. �r . i 1;7��� 1 . .:�,t. � �t''li.'I,A•{,)�f 4(' -•,,���•7.'�,�•� r,W+....� •:J 5}, +. r trt '. r Pdd � 4'j�F+�t"], � /.,r 11 7 7 4' t!r � � 't t� +,.•`,^7 �t'' r 5 � �`/al z 'i• r � a , 1 ;f 5 R.+\ J!1 � *,�+.7,t '"'r.A'.�'+�, •*...,.,•t..!+ ,i;ii`•r t t r7 p1 ,! , ✓r `{1 k \Y{,i.i.GL r7�,r� y '�' � '�: �""""at•"^•••.,'^--•�'":>t" ,.Yr } . �n��: [1 15, 7\� } ,! .1 p f �5,� �r7 'r { ,rn r f0���`*�`"t-r•�,?yw i :{±1`' � S,, ',►1d 1 5f f { ' J �`, ;`;'s �r" 4��2 ' r .S 7f c+ ,� :'15 [ ' to• � 1 .1t�, •. .� S4r 1��ir,�q,'r�"�'."."'''^"�' r f) ,' t 5 J f , l-. (� t� 1 ��•'� -�C(li. )�t` it IPtr'.•- .""�' r At Y., r t } r •J•` t i t -. r , 1 t ( l l s r ^ r r � t7 (r t +'�yt�f, .'• �• 5 Iy:. Y. t L,rY rr )7 'S"Iv�' tr .!l7 +3 '� r5�i1•:+FSI� :.', .,.. w�•• f �.I r� j .1 -}°i:{5�f�y�h t,1 aJ�r„ 5 f�� I"+" xt3��'li��Y (y5�,l ,YRAAz pct[('{ T1"t f{a'75 7 �3 ;.c���•qr z ,t� +`� 5 r 1,` �t) l�/'�'rf'J•', ( j frl�y �,r?(�f ''.` f St.:rC '4 <'I,S' J"JI}Fitd' S+f,'r ,1r151t f 7(idt/Jr +tJ`h.XJac ift it �•,5�� vrsx 7r.rr ( L{. r rlt tfl�•y . F i_ �7 llt.SiJ Jy7 s �f ftp ;f,r lSl tJ,f/Klpi'� r�• �\�.�,^tV,�_C t' /�7 r 7. +•<S.�i'af{k5r, �,,L Y a :i � .. r if r ! ,t.l r7 iir �ftQ�l(/ 1 1y1 ,t�L! 5t}�1v•• � it'S 1 :tt \�,lr✓�•, `'j 7.,�5�,'7,/1 1.�'rF„`. .tJ Jt '' .... .,5'.lr. 1 ,�n.(r}t `'{ 1. 1 �•. 1 :f rY? `_ r 1 ; v. ;yft•• 7 [ tz}' S, f�f 1 .) ;s fjr�.�t, pr ,r4.• k. 5:'¢�'�{!1',� f r{ S (<7 5 ) C{� 7 Cr. JS r'•' r t f t JI, t 7/.,h;^ � r �. i ,Nf ,1�'r [Iyj,rf t 5i S `p �.t{,{pf1• "tlr. j r )� �. I.tl •!_•tlJd.w. +1r" � r j f t'c��t yJ01'7�K•. i s R �� V ��.Z 'f 5 I �J'�ff�'s ' yrFN ,��7 •C715 Ct7l YF %1 7 l t77` l' S1. ' 1 (� .t r x, _c ; •1^r 5J'l 7 rr _._,_._ .. ui ;1 � s r { ;r t 1 \� ; Ll+n,1 7 .:,°•-"""".��-_ ,. .._._...__.__-__. _ /' � • f, r .;i � ,Iii ) � 0 � � r,� . {y I.�l C7 �,.• 17.. r IJ :1`r "�.➢li �CSt�I 1117'���,' � ....-.. _. 7 J_:J._ rr,l /�a+f h� •1��'•,,�>� /7 t r,y ! rr71',{ t ,7` �" 5 f .y 1A, r!f/t ,$�r J �• jaJ.3„�IJ f(p" , b:•tr 9 • 1 f ./a '.F �. r ,,;..!'! 'da rl r�1a: 1 f, j511 'Aj f friar❑ � "^4i'Lr1s.j 0 , j r / : r t h},I,.'Z y'.J�/•-t`!! !f r x,f�+G.l�, r/' ,u.Ff ) d �'/•� a �Jr, ! ' .H" ! j ' J r �•f.� t'rr�ft:f.7�J'�IS af.!r✓,...� :l )-j '� ',r f R :•'£ 1 � � i � Y � S >� 1 tl` I s)s•17,.l rrl.j�f7t7<1 }A7t J •.g: r 7Lr +f, / :!i• '�'. , ..J 1a� �r ��' / }'� t '� (, � Orf f rr, {�rr t.,• `r 7 � T r 1•+ � y�- 3� w l��'�y:if'a('�'•(ple�'/7'.Y 4 �� i'i.,y�rt7')�1`'ta xf, 7�i f.{ is{).r 1/ f r� do ,. ! - 7- 7 �: �, jr�r f tr73/a.(,i7y���f,�t 5•. (+ 1 ,,,V fi t t ( xf lrl ,ft•( 1 q, J x 1, {b. Jl, f�(�\} Z p,SyY.'t tj � 1'♦•ii I t,(({.1,11I C(h 1d} 15f y ) t lV�Y_j15'1Jr �I.�j •"l. lei r• 2 �i';(`l�i', ? ryf� i"'f r�.7"5 stlr� raj Jy��.�+�,{• 4 f.. ,,_n h�,,, `�`v ,,�[/- `'•P�S''4���tvi(Ct f{r�"�l' '':� {F..4� .t. t}�l'l�/�{)+e `�1 it��.y:•t(+a• �.[`t'J�® t t(•'`ti 57'r � -r 4 Vit' " "'r r'' rf!'. '� �',�r& r sJt•+ti 7 ( 5l17 Y-. t +t• Eri' 'x' 1�'V 7 r f�,L '\ �"+�fl:L'ifJ,,'��:�' •ya ..�s ,�+11:�II �' �,i��fl1 r,}�'�'1` 3�,#•�;l/..�a �51�r�t"C' S?l. ��,,rp��. ,- :jam A?1...ti'',;.Nr; r, �'fY; ,�' � '� .�iy7yr`�ad� _+ ;µst}:fd'� �F7+ l��l•(,�(s,l.'r�.�:,f1 r�' Itv�i Jt r f'�(iI J•I R y .,�„" �.� ,,;_ � t�v t{ i t�f,Y J.�t�jltjfy;1 '9C•. it ,J1.(+�,,lr- 1f� ,S!"i5 ',^{�dr rJ J,��.f)f�aif�� ..>>r 31 ,fig ....,.,,.`..�r:4:f:rtr,." r5. .._� ... .....f•. ,r r: �+r , v{- '}- ,F `, '(i' �j, �'rl �73(� '• '�m� �'7�� L��f�� P)'j'r ft,�1'7 u.lsry],.t.•,Q� .,.i, .. y��� s. 0 %�s�A � u , >•� �i"1 f' 1 t� �'+n f tr.F Yr :.`/ rl�� a! Y�.r} ,r yr�S r ' ���""f,i{Cf t +'"nr(Ji sly 7 ♦. ati v.1 ^�t f(rt•�l i . is ;t E / Ivy }",[/�1, ` Y/,.��/•r{�i�`f� ,;" " lc� � 'r,�j:l�' 4.jY+.t`t`�.tr.`1' ". 1,.` J.Itq `r``• �i.wYf F+`4 JI�,���,� fFf�s a �r}1"2A ;f t/Lr1�'�!jtGti ` .{t �. 7 •��,. tri - __ ` {'t ., 'i t!{�f{9JJ'� ''.5 Al •�r�!`u .,.;... �G+�sii.� ry'y' .' (• Y j `ir""q",�' (I f ly r 1./••1:'=�-(r- n*+1 —� 7 f Jrrrr�� Y. S� tf�)ir,. tee..�.. •l Jilt �:Aj�'f. {_ ,� �''� .•+-:c.,u.•.!•'.4:.I Y� f (5 / ,.•I 1' --•—_�._-_. '7♦t f t r' ,�r.'r �.,. -lm+lis;'4 '1,x� r�-•�..�.",'sf i U`'!R!:nF'•}r t,,.'• i _.+ y ;'� +.+....�'. d,7 ,. ve'•!I � f)T'J'ri (p;•`• � r ' `3j7 s ' a< Yt n.'4w>l.r f a Ub 7 if,.. r t �' " � •` �' w{w,a - Pa rg�•S,l r -r i22+! ���� .. t� 7r'C'`°r' �•: 1',(�S{p� 5,`{,•t'S�? � •l' .. r f r r i 7 r�'S�'(�{ 7 i.;+7-y �°* C.'t a- �y?..f�••f{".t i�{a 1 C1Y ` ' •:1 r i r 7 t'• [ Y. ri '•N4 l !�'f ��f j�;M:#`�r�,�� 1 f '' / j 7 ti r, 7 ��J ) �7 !`�f� +!r"; >; �� r� 7� � �>�r r 1 t � �' b 7. i < i i 5, it r!!. . s i•�. �7�,St�t.1 >{'C""u'{+4. �, ✓1'!,f"A� lS5l�Y r��:�^I, ' •[! 1 Y f( � y v �pp•� t3.{�ri21{�k!'�,�7 1it'J/it f1,rf` /577t'd l� f f' � �t ) I V 575 1 /f.d Yti r, f r7 f ,cy t� i :r. J ',� ), tl.r ,1� ,f � � .7 r.i• J 1. ,d. 1'•�: N'i"y �IiY � I •s�. (5 g_"r ��yy ��StY' Nov 10 1994 Welcome to ALLAN BLOCK. We have put this Design Manual together to provide you with a handy reference guide for the design and installation of ALLAN BLOCK retaining walls. Inside you will find a broad array of information to help you develop a quality solution for your retaining wall project. Since we began building ALLAN BLOCK walls in 1986, we have learned a great deal about our product and its capabilities. With over five million square feet of retaining walls installed, we can provide you with a complete package — product, price and service — to answer your retaining wall needs. Thanks for selecting ALLAN BLOCK. Robert Allan Gravier AL1 nV TABLE OF CONTENTS • PRODUCT OVERVIEW A quick reference on basic ALLAN BLOCK information and engineering advantages. Pages 2-3 • DESIGN GUIDELINES Nq1 PANT Evaluate your job site and develop a plan for each retaining wall. Pages 4-5 / f • INSTALLATION GUIDELINES Tips on basic installation, plus a complete library of construction details, including stairway installations and water applications. Pages 6-11 • SYSTEM OPTIONS -- Pick the wall system to match your site.Choose from Gravity, Geogrid,or Masonry. H `'- Pages 12-19 8 • APPENDIX Use the handy forms in this section to specify, design and OMRMT DE"PAD order material for each wall project ` Pages 20-24 nV AV This manual covers a wide array of retaining wall situations. If your project falls outside the scope of the information provided, our trained wall experts are available for specific project assistance. Simply phone 1-800 899-5309 for help on your specific wall project. i PRODUCT OVERVIEW yy' PRODUCT SPECIFICATIONS cf STANDARD BLOCK GENERAL •Coverage............................ .75 sgft/block 13 blocks/10 sq.ft. !; •Weight........55 lbs/block •Set Back.............................. 1-1/2"/block '1-- 7-5/8" 12°from vertical 6-7/8" ALLAN BLOCK WALL TYPICAL SECTION e!5-5/8„-s/8y � OPTIONAL CAPSTONE ANGLE BLOCK •Weight........45 lbs/block /( ALLAN BLOCK 6-7/8 22.5' 7-5/8 BACKFILL i � H �\ � DRAINAGE FILL qq 15-5/8" tl -5/$ \� / UNDISTURBED CORNER BLOCK Y suecRAOE •Weight........50 lbs/block B °'' `' • COMPACTED I' � �?�s%� sd GRANULAR BASE 6-7/1 8' 7-5/8' ' 7-5/8j3-5/8"/ CAPSTONES •Capstones are available at most locations. Call your nearest ALLAN BLOCK Dealer for specifications. " n� "Note: Weights are approximate. Dimensions may vary due to rock face finish. ah INSTALLATION OVERVIEW PLAN Begin your retaining wall project by developing an accurate plan of the site. Locate all lot lines, utilities, building structures, driveways and parking areas. Note any permanent r trees or vegetation. Indicate the drainage patterns and site 0 contours. Identify the soil type and classification, and note slopes above and below the wall location. Indicate dimensions and elevations in the area of the proposed wall. A careful site analysis will help in the design process. DESIGN With the site layout and analysis complete, you can begin the design of the retaining wall. Develop a layout that will maximize drainage and direct the flow of water around the wall and away from buildings and structures. Select a reinforcement option for taller walls using the manual. As you develop the wall layout, be sure to consider the job site conditions for material and equipment access. Try to minimize the excavation and hauling of soil and fill. And of course, develop a wall design that FP reflects the style and character of the surrounding landscape. BUILD With the design complete, use the order form in the back of this manual to calculate and order the materials for your project.The basic construction techniques are outlined in the 15Y' following section of this manual. Begin the construction of the retaining wall at the lowest point and work upwards.Always build on stable, well compacted ground. By spending some extra care and preparation on the base and bottom row of block, the rest of the wall construction will go smoothly. As each new row of block is stacked, take a moment to make minor adjustments in alignment and leveling. t: 2 . . PRODUCT OVERVIEW ALLAN BLOCK ENGINEERING The Allan Block Retaining Wall System combines basic engineering W=WEIGHT OF WALL principles with a construction form known and used worldwide for over 75 W years—masonry block. Developed by a Civil Engineer in 1985, over five million square feet have since been installed throughout North America providing structurally sound solutions on a wide variety of difficult sites. H From drawing board to job completion, Allan Block Corporation provides P. = ACTIVE SOIL the level of service needed to see each project through. For projects that PRESSURE fall beyond the scope of this manual, call the ON-LINE ENGINEERING B number — 1/800-899-5309. Our trained personnel stand by to provide Pp RSA.: preliminary engineering and construction details as needed. When RS=SLIDING RESISTANCE specific working drawings and on-site engineering are required, access Pp =PASSIVE SOIL RESISTANCE our nationwide network of licensed geotechnical experts. ENGINEERING ADVANTAGES INCLINED WALL SURFACE Retaining walls are engineered to counteract the forces and pressure from a sliding wedge of soil that exists behind that SLIDING WEDGE wall. This "sliding wedge" is the soil that extends beyond the 12 SLIDING COMPARISON natural angle of repose for that soil type. When the wall WEDGE VERTICAL WALL ALLAN BLOCK surface is inclined at an angle of 12°—the slope of an ALLAN WALL BLOCK wall —the size of that wedge is greatly reduced. And 45'+ /2 so is the amount of soil being retainedl That significant FAILURE reduction in the size and weight of the "Sliding Wedge" yields PLANE lower soil pressures on the wall, lower reinforcement requirements, and greater system potential. HOLLOW CORE SYSTEM ALLAN BLOCK'S hollow core system provides numerous advantages over solid wall HOLLOW CORE SYSTEM products.The lower unit weight allows for easier installation at the site, and less g*GEOGRID ITIVE DRAINAGE chance for back injuries from lifting heavier products. Once the core is filled with granular material the ALLAN BLOCK takes on the same unit mass as a solid block, SITIVE GRANULAR providing equal retaining ERLOCK p g q g potential. The granular infill material creates a "drainage zone"within the wall and reduces the amount of drainage fill required behind the wall. And the granular material provides a positive interlock between the blocks, and a INTERLOCK positive interlock with geogrid reinforcement fabrics. nV AL1 SYSTEM OPTIONS ALLAN BLOCK walls can be adapted to meet the structural requirements of any retaining wall site. Lower profile walls can often be built without any reinforcement using the Gravity System. Taller walls can be strengthened with either Geogrid or Masonry.To;select the best system for your project turn to pages 12 through 19. ALLAN BLOCK WALL-GRAVITY SYSTEM ALLAN BLOCK-GEOGRID SYSTEM ALLAN BLOCK- MASONRY SYSTEM TYPICAL SECTION TYPICAL SECTION TYPICAL SECTION OPTIONAL CAP BLOCK OPTIONAL CAP BLOCK ALLAN BLOCK OPTIONAL CAPSTONE ALLAN BLOCK D ALLAN BLOCK DRAINAGE VERTICAL BARS BACKFILLED H FILL GEOGRIDS BOND N {{ BEAM DRAINAGEDRAINAGE FILL DRAIN TILECONCRETE FILL AS NEEDED D3 GROUT '• AIN TILE AS NEEDED UNDISTURBED B SOIL B COMPACTED g FOOTING COMPACTED GRANULAR GRANULAR BASE T CONCRETE FOOTING • BASE �w 3 fi DESIGN GUIDELINES ah SITE ANALYSIS Your retaining wall design must begin with a proper site analysis. The conditions at the job site will determine wall « � heights and locations, as well as reinforcement requirements. Use the guidelines below to assist in your wall design. SOILS Soil conditions behind and below each retaining wall have a direct effect on the strength needed in that retaining wall. For proper wall design it is critical to make an accurate soil analysis at the site. SOIL FRICTION SLIDING BEARING EQUIVALENT The pressure from the soil behind the wall will vary a ANGLE COEFFICIENT CAPACITY FLUID great deal depending on the soil type. In general, a wall TYPE O PRESSURE built in clay soils will require more strength and reinforcement than a wall of the same height built in FIRM CLAY 260 .40 2,000 Ib/sq.ft. 60 Ib/cu.ft. sandy soils because the clay exerts more pressure on the wall. SILTY CLAY 280 .45 2,500 Ib/sq.ft. 50 Ib/cu.ft. Check the soil type and conditions at the base of each MIXED SILTS 300 .50 3,000 Ib/sq.ft. 40 Ib/cu.ft. wall for adequate "bearing pressure." The soil below a wall needs to be strong enough to support the weight of f SANDY SILTS 320 .55 3,500 Ib/sq.ft. 35 Ib/cu.ft. the wall resting on it. If the soil is in a moist or wet condition, extra precautions may be required to provide a ,Q CLEAN SANDS 34° 60 4,000 Ib/sq.ft. 30 Iblcu.ft. stable base. 3 !; Use the soil classification chart above to identify the basic properties of the soil at your site, and refer to the pre engineered charts in this manual for construction guidelines. ab n� SLOPES When the grade above a retaining wall is sloped, the extra soil being retained will add pressure to the wall. Extra SLOPE 2 reinforcement will be required to compensate. Slopes are often W�LE I identified by the horizontal run to vertical rise, and typically vary SLOPE IL BELOW from five to one to two to one. WALL ii When the grade below the retaining wall slopes down and away K3 I from the wall, care should be taken to properly lock the base of the t 2 } wall in place. For slopes up to 3 to 1, bury 2 inches of block for every foot of wall height. For slopes steeper than 3 to 1, bury three inches of base block for every foot of wall height. r lob ab SURCHARGES Any added pressure applied above a retaining wall is called a "surcharge." Parking lots, streets, swimming pools, and building foundations are common examples. This added pressure needs to be considered when engineering the retaining wall. Surcharges are calculated in pounds per square foot (psf). A SURCHARGE typical design value for parking lots is 250 psf. 0 u ab a TERRACES Terracing a hillside often provides for improved aesthetics and easier installation than a single tall wall. If the distance between terraces is too small, however, the upper walls will exert added pressure on the lower walls and create an unstable condition. s When the distance between two terraces is less than two times the height of the lower wall, the design should be evaluated for overall stability. 4 DESIGN GUIDELINES loll t WATER MANAGEMENT Retaining walls should always be designed with consideration given to the management of water at the retaining wall site. Proper grading and drainage planning will ensure a quality wall solution. aa� GRADING Develop a grading plan that routes water around the walls as much as the site will allow. Provide swales above and below the wall as HIGH POINT permissible to accommodate. Avoid retaining wall designs which permit pooling and collection of surface runoff above the wall. Contain sources of concentrated water flow such as roof scuppers, downspouts, roof drains and valleys, and route them around the wall ends accordingly. i alb ah DRAINAGE { Water that can not be directed around the retaining wall must flow over or through the wall. A good drainage system can be integrated into the ALLAN BLOCK wall to manage that flow of water. ALLAN BLOCK walls are actually vertical "french drains". The granular material used in the block cores and immediately behind the wall creates a drainage zone which allows water to flow down through the wall and out at the base. Drain tile and outlets should be added on taller, reinforced walls to '"'"" -A" \� ;41 handle the larger volume of water moving through the wall. OUTLETS DRAIN TILE a� a� WATER SITES ALLAN BLOCK walls can be built on sites where water is present at the base of the wall. Lakeshores, holding ponds, stream beds and even sea wall applications are all easily handled with a few modifications to standard construction. These sites typically require a closer inspection of the soil conditions and engineering requirements. DESIGN CRITERIA FOR WATER APPLICATIONS Foundation Strength TYPICAL SECTION Walls built in sites with moist or saturated soils often have poorOPTIONAL CAPSTONE soil conditions at the wall base, and will often require additional stabilization to provide a proper foundation. ALLAN BLOCK Wall Reinforcement BACKFILL ,` When water penetrates the backfill soils behind a wall, the soil • GEOGRID becomes saturated and heavy. This increase in "hydrostatic .• r.,. . WA t. T pressure" ER LINE VARIES will r .. P require added reinforcement m the wall to •• � FILTER FABRIC compensate. Water Movement DRAINAGE Walls built in water applications often have some movement in RIP RAP FILL DRAIN TILE the adjacent water. Stream beds flow"' along the l base. Wave e action at lakeshores and sea walls moves water up to and away from the wall face. This water movement causes a suction like � force which can scour the soils away from the wall foundation. COMPACTED GRANULAR BASE Retention ponds rise and fall with each rainfall. Added drainage WITH GEOGRID may be required to aid in the removal of water from behind the REINFORCEMENT wall as the pond level recedes. ALLAN BLOCK walls built in water applications should be carefully designed with these conditions in mind. Turn to page 11 for recommended construction techniques. Be sure to contact an ALLAN BLOCK representative or qualified engineer for your specific design. 5 d y INSTALLATION GUIDELINES ` GETTING STARTED { By using the proper tools and materials and by following the Basic Installation Guidelines, construction of Allan Block walls can be simple and cost effective. i BASIC TOOLS OPTIONAL TOOLS MATERIALS •Wheel barrow • Mechanical compactor .Base .........................Compactible granular material •Shovels •Skidsteer loader (eg: 3/4" minus\road base) •String line •Power cutoff saw gg y • Level •Transit •Drainage Fill.............(ege3/8ain3/4'�c uslar hed stone) • ial Hand compactor •Maul •Geogrid •Capstone adhesive •Brick hammer •Drain file •Sand S nV nV CONSTRUCTION �+ BASE PREPARATION Begin by excavating a shallow trench along the planned flocation of each new wall, being careful not to over excavate. The trench must be deep enough to accommodate a layer of compacted granular base material and the amount of base block required below grade to lock the wall in place. Base material should consist of compactible granular material, (e.g. 3/4" minus road base). For walls up to four feet high a 3-inch deep by 18-inch wide layer of compacted base will be sufficient. For taller walls, a 6-inch by 24-inch base is 3" to 6"7Q,FOR EACH FOOT �I` recommended. Plan to bury one inch of base block for each OF WALL HEIGHT foot of wall height. 18" TO 24" BASE INSTALLATION Place the proper amount of base material in the trench. Rake it smooth and level, and compact by hand or by mechanical � tamper to 95% Standard Proctor. All walls should be constructed on stable, well compacted ground to prevent major settling. Place the first row of Allan Block on the compacted base with the raised lip facing out and the front edges tight together. Level each block from side to side and front to back. Carefully back fill around the base block and in the block pockets with base material and pack to lock in place. Check the level often and sight down the base course for straight lines and smooth curves. ADDITIONAL COURSES Sweep the excess material from the tops of the first row of the blocks. Position the new row of block on top of the first row so the seams are offset from the blocks below. Perfect "running bond" is not essential, but a three inch minimum off set is recommended. Check each block for proper alignment and o level. Sand can be used to "shim up" the low spots and smooth out straight lines and curves. Fill the block cavities and immediately behind the block 6 to 8 inches with free draining granular material (3/8" - 3/4"crushed stone). Back fill the remaining space behind the second course with on site .� soils and compact. Lay up each subsequent course in the like manner until the wall is complete. 6 4 INSTALLATION GUIDELINES STEPPING UP Always begin your wall construction at the lowest possible point and "step-up" with the base. A string line and line level will keep each new row of blocks on track. STEPPING DOWN When the top of your wall needs to"step-down"use corner blocks at the end of each row to provide a perfect finish. LEFT HAND RIGHT HAND CORNERS CORNERS e t, •.l1• M Wim, AL1 AL1 TOPPING OFF The ALLAN BLOCK SYSTEM provides a wide variety of options for finishing off the top of each wall. The raised lip on the row makes an excellent edge to finish to, and makes cap blocks unnecessaryl By leaving the top blocks partially unfilled, decorative rock or wood mulch can be placed right up to the edge.By;filling the top row of blocks with planting soil,flowers shrubs or ground cover can be planted right up to the front to give the wall a soft green look. If a capped appearance is preferred,matching capstones can be placed on the top row and attached with a construction adhesive. CAPSTONES w AV 111111646 Al 7 'INSTALLATION GUIDELINES CURVESy Serpentine and curved walls are built by combining Allan Block's special angle block with the standard block. Inside curves are simply built by placing the front face of the standard block edge to edge and fanning the block to form the required curve. Outside curves with a soft flow(radius>6 ft.)will give the best fit and smoothest appearance. Soft outside curves are formed by alternating angle blocks and standard blocks. For tighter outside curves(radius <4 ft.) all angle blocks are required. To calculate the number of angle blocks needed in a curved wall see the order sheet on page 22. OUTSIDE CURVE OO OD O � O INSIDE CURVE 0 [10 CORNERS o n� n� CORNERS • Inside Corners are constructed by modifying standard blocks. • Outside Corners are constructed using the special Remove half of the raised lip from a standard block (they can be "corner blocks." Alternate right and left handed blocks chiseled off but a masonry saw cut works best). Lay the modified block on each course to obtain a perfect corner. perpendicular to another standard block with the lips lined up and complete the base row. On each successive row, simply reverse the I position of the modified block to obtain an interlocked corner. k REMOVE LIP ,Agtxj STEP 1 STEP 2 n ah h ANGLES With some simple modifications to standard and angle blocks,inside and outside angles can be built.Some cutting and fitting will be required to make tight fitting seems. Properly built,the blocks will overlap and interlock at the angle. INSIDE ANGLE REMOVE SIDE OF OUTSIDE ANGLE u REMOVE ANGLE BLOCK CUT ANGLE BLOCK LIP OLINE UP RAISED LIPS O 00 [11 O1-1 STEP 1 STEP 1 INSIDE ANGLE OUTSIDE ANGLE OVERLAP STANDARD ALTERNATE BLOCK BLOCK POSITIONS ON ®® ®® lo® INSERT HALF NEXT ROW ANGLE BLOCK ALTERNATE BLOCK POSITIONS STEP 2 ON NEXT ROW STEP 2 8 INSTALLATION GUIDELINES all _ 1; PLANTING Installing plant material above an Allan Block wall is effective TREE PLANTING and easy. Uncapped walls can accommodate smaller plantings right up to the front lip. GROUND COVER PLANT MATERIAL ALLAN BLOCK PLANTING SOIL DRAINAGE FILTER FILL FABRIC TREE TOPSOIL SOD TREE GUARD SHRUBBERY PLANTING PLANT SOIL MULCH o MATERIAL ROOT ALLAN MULCH BARRIER BLOCK PLANTING DRAINAGE SOIL FILL DRAINAGE qi FILL ALLAN BLOCK ah a� FENCING & RAILINGS Several options are available for design and installation of PIPE RAILING/CHAIN LINK fencing and railings above an Allan Block wall. In areas of heavy traffic above taller walls, railings may be required for safety. PIPE RAILING WOOD FENCE ALLAN BLOCK CONCRETE DRAINAGE FILLED FILL CORE GUARD RAIL WOOD POST WITH FENCE TREATED WOOD RAIL OPTIONAL WITH LAG SCREWS CAP BLOCK COUNTERSUNK ALLAN TREATED BLOCK7., WOOD POST CRUSHED STONE ALLAN OPTIONAL OR CONCRETE BLOCK CAP BLOCK DRAINAGE DRAINAGE CONCRETE FILL ° FILL 9 .a INSTALLATION GUIDELINES STAIRS Building stairs with Allan Block is simple and effective. By following some basic construction techniques a variety t of configurations can be built to best match your site. nah BASIC INSTALLATION Step One — Prepare granular base and install first course of INSTALL UPSIDE- REMOVE LIP Allan Block at location of first riser. Be sure to DOWN bury enough block to lock in place Step Two — Place Allan Blocks upside down at location of second riser and level with top of first riser. , o Backfill in and around the first riser and buried block and compact thoroughly. 4 Step Three — Install the second riser on top of the buried G block. Some cutting may be required to fit the block to the adjacent walls. • a CHECK Step Four — Install the next row of buried block. Backfill and FOR LEVEL i continue. e r. 1 BURIED UNDISTURBED BACK FILL SURFACE UPSIDE-DOWN SOIL COMPACTED TREATMENT BLOCK :..... GRANULAR BASE :...: 'p ' COMPLETE nV nV DESIGN OPTIONS PARALLEL STEPS r 'i Parallel Steps will follow the natural set back of an Allan Block wall. To maintain a constant stair.width, remove lip off of the blockj.L where each riser intersects with the wall. ^;ALLAN BLOCK Perpendicular Steps will increase in width by 3 inches on each COPING STONE riser due to the set back on each side. Some cutting and fitting will HARD SURFACE be required. Intermediate landings will help control and balance stair width. y ,y Free Flowing Steps are built independent of a wall system and follow the natural contour of the grade. Use corner block. Use X' corner blocks to finish off the ends of each step. PERPENDICULAR FREE FLOWING STEPS r STEPS GA, ris r 10 INSTALLATION GUIDELINES WATER APPLICATIONS To build ALLAN BLOCK walls in water sites, use the basic construction techniques outlined below. Every retaining wall built in a water site will have its own unique set of site and soil conditions. These walls should be carefully designed for proper performance. Check with Allan Block Corporation or a qualified engineer ah ah FOOTING DESIGN A footing analysis may be required to insure proper stability. If SHORE LINE PROTECTION soil conditions at the wall base are poor, unstable, or frequently saturated, the footing will need added strength to prevent settlement or movement of the wall. OPTIONAL CAPSTONE OPTION ONE - Drape a sheet or filter fabric in the trench and up the slope behind.lnstall a granular base using clean ALLAN BLOCK material (no fines) graded from 3/8" - 3/4". Place the granular BACKFILL base material in the trench a minimum of 12" deep x 24"wide ` GEOGRID and compact. Install a strip of geogrid as needed to provide Q added reinforcement. WATER LINE VARIES ' FILTER FABRIC OPTION TWO - Install a lean concrete spread footing with0" t'r' :•" wire mesh or steel reinforcement. Wet set the base course of DRAINAGE Allan Block to provide a positive interlock. FILL OPTION THREE On water sites with significant water RIP RAP DRAIN TILE movement, the footing should be designed for scour protection. Consider a vertical footing design with steel reinforcement and a ? . shear key. Construct the footing to a significant depth below the COMPACTED water table to prevent scour. GRANULAR WITH GEOGRID SE BLOCK PLACEMENT REINFORCEMENT Install the base course and additional courses of Allan Block in the same manner used for standard construction. DRAINAGE FILL FILTER FABRIC Use a clean granular material:with no fines for the drainage By installing a filter fabric in the base trench and up the slope, fill.On sites where all or parts of the wall will be submerged, you can prevent the on site soils from migrating into the granular the depth of the drainage fill should be increased. base and drainage fill. DRAIN TILE RIP RAP On wall sites with vertical water movement, such as retention Install a layer of rip rap (large granular stone material 6" —8" in ponds, install drain tile and outlets just above the low water size) at the wall base. Walls built in sites with significant water line. Always provide adequate drainage from behind walls movement should have a minimum layer of 18". built in water applications. nVab RETENTION POND STREAM BED WITH SCOUR PROTECTION OPTIONAL CAPSTONE OPTIONAL CAPSTONE ALLAN BLOCK HIGH WATER ELEVATION BACKFILL ALL BLOCK BACKFILL v V v '�• GEOGRID HIGH WATER ELEVATION ;;•:;; GEOGRID :,• . FILTER FABRIC FILTER FABRIC STANDING WATER DRAINAGE FILL ELEVATION e DRAIN TILE RIP RAP DRAIN TILE RIP RAP V DRAINAGE �: BOTTOM COURSE FILL ` REINFORCED GROUTED 2x4" SHEAR KEY CONCRETE SPREAD FOOTING STREAM BED REINFORCED CONCRETE WET SET ;' TOE FOOTING - 3000 PSI BASE COURSE REBAR if , a u� SYSTEM OPTIONS a i 'r ALLAN BLOCK WALLS can be adapted to meet the structural requirements of any retaining wall site. Choose the system that best meets the requirements of your retaining wall site from the three options below. r I aah GRAVITY WALL SYSTEM ALLAN BLOCK GRAVITY SYSTEM A wall that relies solely on its own weight to stand up is called a TYPICAL SECTION "Gravity Wall."Allan Block combines basic engineering principles and simple mechanics to make a great gravity wall. ALLAN BLOCK OPTIONAL CAPSTONE 21 Each Allan Block weighs just 55 pounds when set in place, but 111=III over 90 pounds when the cores are filled -the same as heavier, 11- COMPACTED bulkier products. The 1.5 inch set back on each row of blocks ••1111—I1�1 BACKFILL creates maximum leverage for the ninety pounds — more H =11 leverage than vertical walls. And the same set back provides an — DRAINAGE added benefit by significantly reducing the amount of soil that .• T FILL t+ needs to be retained. Lower soil pressures, greater leverage, I UNDISTURBED and equal weight at the site - these simple principles let Allan III SOIL Block outmuscie heavier,costlier, and bulkier products. B COMPACTED i Check the GRAVITY WALL CHART on page 13 to find the GRANULAR Y, maximum recommended heights for Allan Block walls for various BASE site and soil conditions. ah ah GEOGRID SYSTEMS ALLAN BLOCK GEOGRID SYSTEM P When wall heights and soil conditions exceed the gravity TYPICAL SECTION potential of an Allan Block wall, geogrid fabrics can be integrated -OPTIONAL CAP BLOCK to provide the required additional strength. Geogrids are LLAN synthetic meshes that are manufactured with high tensile BLOCK GRID strength and designed specifically for slope stabilization and earth retention. By placing layers of geogrid at specific lengths of DRAINAGE embedment behind the wall, frictional forces develop between H FILL GEOGRIDS the soil and the grid to create a unified soil mass. This soil mass provides the additional resistance needed to offset the pressures DRAIN TILE , from the slope being retained. Geogrids are available in a variety AS NEEDED 2 3 of types and sizes. The amount of grid required on any specific project will depend on the site conditions, wall heights, andCOMPACTED strength of the grid being used. Check the GEOGRID CHARTS GRANULAR on pages 15-17 for more information and pre-engineered BASE solutions. A ah MASONRY SYSTEM ALLAN BLOCK MASONRY SYSTEM When wall heights and soil conditions exceed the gravity TYPICAL SECTION potential of an Allan Block wall, traditional masonry OPTIONAL CAP BLOCK reinforcement techniques can be employed to provide thewxw required additional strength. Calculations and design techniques ALLAN BLOCK for this method follow accepted ACI masonry standards and VERTICAL BARS existing UBC design criteria, while including the benefit of an inclined Allan Block wall. A footing is designed to an appropriate BOND size. Vertical steel rod reinforcement is placed through the cores H BEAM DRAINAGE of the blocks and grouted. The rod reinforcement is located as CONCRETE FILL the site conditions and wall heights require. Unreinforced unit GROUT �P cores are filled with free-draining granular fill as each course is AIN TILE AS NEEDED installed. This reinforcement technique is particularly useful on FOOTING job sites where geogrids are not feasible or cost effective. Check B �A REINFORCEMENT the MASONRY CHART on page 19 for more information and T CONCRETE FOOTING � pre-engineered solutions. 12 W i SYSTEM OPTIONS K!r.1 f10IAAQ GRAVITY WALLS _I A wall that relies solely on its own weight to stand up is called a "gravity wall."Allan Block functions as a gravity wall to heights as high as six feet, depending on the site and soil conditions. To find the maximum height of an unreinforced Allan Block wall (a gravity wall) for any specific project, match the conditions.at the site to those in the table below. ah all ALLAN BLOCK GRAVITY SYSTEM Allan Block combines basic TYPICAL SECTION engineering principles and simple mechanics to make a great gravity wall. Each Allan Block OPTIONAL CAPSTONE weight just 55 pounds when set in place but over 90 pounds when the cores are filled. The 1.5 inch set back on each row of blocks creates maximum leverage for ALLAN BLOCK o °. ° i��i��ii��ii �\ that 90-plus pounds to offset the soil pressure. That same set back • ° ° \�\\\\ r /� provides an added benefit by H o - ° \\�� �� r COMPACTED significantly reducing the amount BACKFILL of soil being retained. ° \ r DRAINAGE FILL Allan Block functions as a gravity \��\��� r wall up to specific heights. These • i�yi�yi /yy� heights are determined by site \ and soil conditions. B comparing ° ° /��\\�\r� (ice UNDISTURBED the resistive force from the o° SUBGRADE leveraged 90-pound Allan Blocks r / with,the soil pressure exerted by various soil types and site COMPACTED o r r conditions, maximum GRANULAR BASE unreinforced wall heights can be calculated. Check the Gravity Chart below for those heights. ALLAN BLOCK GRAVITY WALL HEIGHTS Recommended Maximum Wall Heights-In Feet Unreinforced ALLAN BLOCK Walls CONDITIONS ABOVE RETAINING WALL SOIL TYPE 0 LEVEL 5 TO 1 4 TO 1 3 TO 1 2 TO 1 150 psf 250 psf SLOPE SLOPE SLOPE SLOPE SLOPE SURCHARGE SURCHARGE FIRM CLAY 260 3.5 3.0 2.5 2.0 1.5 2.5 2.0 SILTY CLAY 280 4.0 3.5 3.0 2.5 2.0 3.0 2.3 MIXED SILTS 300 4.5 4.0 3.5 3.0 2.5 3.5 2.5 SILTY SAND 320 5.0 4.5 4.0 3.5 3.0 4.0 3.0 CLEAN SAND 340 5.5 5.0 4.5 4.0 3.5 4.5 3.5 If the wall heights at your project exceed those recommended in the table above,reinforcement will be needed. Select from the Geogrid or Masonry system options in the following section of the manual. 13 s, SYSTEM OPTIONS GEOGRID REINFORCEMENT �1 Geogrids are flexible, synthetic meshes which are manufactured specifically for slope stabilization and earth retention. These"grids" _ are available in a variety of materials, sizes, and strengths. They can be made of high tensile strength plastics or woven polyester yarns. They are typically packaged at the factory in rolls. The grids d are rated by Long-Term Design Strength with values ranging from 500 pounds to 3,000 pounds per linear foot. I When wall heights exceed those listed in the Maximum Wall Height Chart for Unreinforced Allan Block Walls, on page 13, geogrid can be added to provide a stable wall condition. Layers of geogrid inserted between the blocks and extending behind the wall interlock with the soil mass. This mass uses its own weight and cohesion to resist both the sliding and overturning pressures from the slope being retained. The granular material in the block pockets provides a positive connection between the layers of geogrid and the Allan Block wall and locks the two systems together. In effect, the grid becomes the structure for the slope and the Allan Block Wall a structural facing. The specific location of grid layers and the actual length of embedment of the grid will depend on the site conditions,wall heights, and Long-Term Design Strength of the grid being used. Check the pre-engineered Geogrid Charts on pages 15-17 for general design solutions. ah nV r 9 .0 C L LAYER 7 &.44 L � 4 LAYER 7 ��.•M LAYER 2 yL LAYER 1 LAYER I � LAYER 1 INSTALLATION Site Preparation - Excavate behind wall location for a distance equal to the designed embedment length of the ALLAN BLOCK GEOGRID SYSTEM 4 grid. Store soil for placement on grid. TYPICAL SECTION Base Wall -Construct Allan Block wall following standard OPTIONAL CAP BLOCK guidelines up to designated :height of first grid layer. �— Backfill and compact. ALLAN BLOCK GRID Grid Placement - Cut section of grid to designated NJ' DRAINAGE embedment length. Lay cut edge of grid on top of Allan Block to back edge of lip and extend to back of slope. H FILL GEOGRIDS Place next course of Allan Block on top of Grid and fill block cores to lock in place. Pull grid taut to back of slope and stake to hold in place. DRAIN TILE AS NEEDED D3 Backfill - Place layer of drainage fill to 8-inch depth 2 behind Allan Block. Place on-site soils on remainder of geogrid working from wall towards slope. Compact to 95% ° ° 1 COMPACTED of Standard Proctor. B o ° ` GRANULAR Completion - Install additional courses of Allan Block. Backfill and compact in seven-inch lifts up to designated height of next layer of grid. Install second layer of grid and backfill. Install additional layers of grid and Allan Block in like manner to top of wall. 14 Y ALLAN BLOCK GEOGRID SYSTEM _ The pre-engineered table belowrovides an accurate P estimate for geogrid reinforcement. To use the table follow these simple steps; 1. Make sure the soil conditions at your site match the description in ALLAN BLOCK GEOGRID SYSTEM the top of the table TYPICAL SECTION 2. Select the site condition (Case A, B,or C)that most closely resembles your project site. 3. Choose the wall height needed for your site and read across to OPTIONAL CAP BLOCK find the number of grid layers, embedment length and grid locations. ALLAN BLOCK GRID DESIGN PARAMETERS DRAINAGE FACTORS OF SAFETY ASSUMED WEIGHTSH FILL GEOGRIDS Sliding = 1.5 Earth Backfill = 120 lbs/cu.ft. Overturning =2.0 Filled weight of Grid Pullout = 1.5 ALLAN BLOCK= 120 lbs/cu.ft. DRAIN TILE ,. Grid Rupture = 1.5 Onsite soils - 1201bs/cu.ft. AS NEEDED D3 2 GENERAL SOILS Proper drainage provided. Cohesion = 0 B e ) COMPACTED Grid meets ASTM D-4595 Bearing Capacity>3,500 psf GRID GRANULAR Design Strength> 1,000 lbs/ft(LTADS) ie-Tensar UX 1400, BASE Miragrid 5T, Stratagrid 300, Fortrac 35/20-20 This table should be used for estimating grid quantities for projects which match the site and soil descriptions provided,and only for projects which use grid strengths of 1000 lbs/ft or higher. SOIL CONDITIONS • • o , • Soil Types: Coarse to medium sands, clean sand and gravel SITE CONDITIONS H B TOTAL No.OF Lgrid D1 D2 D3 D4 D5 D6 D7 ft ft GRID LAYERS ft NUMBER OF BLOCK COURSES ABOVE BASE CASE A 6 .7 - Level slope above wall 7 8 1 3.5 6 8 •9 2 4.0 4 8 9 1.0 2 4.5 4 8 10 1.0 3 5.0 4 8 12 12 1.0 4 6.0 3 7 11 15 14 1.0 5 7.0 3 7 11 1;5 19 16 1.5 6 8.0 1 5 9 13 17 21 CASE B 5 ,6 1 4.0 5 Surcharge above wall 6 .7 2 4.0 4 7 ITTIIl nT psi 7 8 2 4.0 4 8 8 .9 3 4.5 4 7 11 9 1.0 3 5.0 4 8 12 r10 1.0 3 6.5 3 7 11 12 1.0 5 7.0 2 6 10 14 18 14 1.5 6 8.0 1 1 4 8 12 16 20 CASE C 5 .6 1 4.0 4 2 to 1 slope above wall 6 8 2 4.5 4 7 2 7 .9 2 5.5 4 8 I 8 1.0 3 7.0 4 7 11 9 1.0 3 7.5 3 7 11 A 10 1.0 4 8.0 2 6 10 14 12 1.0 6 9.5 1 4 8 12 16 20 14 1.5 7 10.5 1 4 7 11 15 18 21 The above information provides general guidelines for the use of the Allan Block Wall system. The suitability of this information and its use for any specific job shall be determined by the user. Actual project details, designs and specifications should be obtained from a qualified professional engineer for each specific project. No provision or analysis for global stability. 15 1 ALLAN BLOCK GEOGRID SYSTEM The pre-engineered table below provides an accurate estimate for geogrid reinforcement. To use the table follow these simple steps;. 1. Make sure the soil conditions at your site match the description in ALLAN BLOCK GEOGRID SYSTEM the top of the table TYPICAL SECTION 2. Select the site condition (Case A, B,or C)that most closely resembles your project site. OPTIONAL CAP BLOCK 3. Choose the wall height needed for your site and read across toe�m oil find the number of grid layers,embedment length and grid ALLAN locations. BLOCK RID DESIGN PARAMETERS DRAINAGE FACTORS OF SAFETY ASSUMED WEIGHTS H FILL GEOGRIDS Sliding = 1.5 Earth Backfill = 120 lbs/cu.ft. Overturning =2.0 Filled weight of AIN illE Grid Pullout = 1.5 ALLAN BLOCK= 120 lbs/cu.ft. DRAIN D3 Grid Rupture= 1.5 Onsite soils = 120 lbs/cu.ft AS 2 GENERAL SOILS Proper drainage provided. Cohesion = 0 B COMPACTED Grid meets ASTM D-4595 Bearing Capacity>3,000 psfGRANULAR GRID BASE Design Strength> 1,000 lbs/ft(LTADS) ie-Tensar UX1400, Miragrid 5T, Stratagrid 300, Fortrac 35/20-20 I This table should be used for estimating grid quantities for projects which match the site and soil descriptions provided, and only for projects which use grid strengths of 1000 lbs/ft or higher. SOIL CONDITIONS • • o Soil Types: Uniform to welld sands, sandy silts s SITE CONDITIONS H B TOTAL No. OF LgHd D1 D2 D3 D4 D5 D6 D7 ft ft GRID LAYERS ft NUMBER OF BLOCK COURSES ABOVE BASE CASE A 6 .7 1 3.0 5 Level slope above wall 7 8 2 3.5 3 7 8 .9 2 4.0 4 8 y 9 1.0 3 4.5 4 8 12 10 1.0 3 5.0 4 8 12 j 12 1.0 5 6.0 2 6 9 13 17 14 1.0 6 7.0 1 4 8 12 16 20 16 1.5 7 8.5 1 4 8 12 16 20 24 CASE B Surcharge above wall 5 .6 2 4.5 2 6 6 .7 2 4.0 3 7 250 psf 7 8 3 4.5 3 7 11 ITTITl 8 .9 3 5.0 3 7 11 9 1.0 3 5.5 3 7 11 10 1.0 4 6.5 3 6 10 14 12 1.0 5 7.0 1 5 9 13 17 14 1.5 7 8.5 1 4 8 11 15 18 1 21 CASE C 5 .6 2 4.0 2 5 2 to 1 slope above wall 6 ' 7 2 6.0 3 7 2 7 .8 2 6.5 3 7 11 8 .9 3 7.53 6 10 9 1.0 3 8.5 3 7 11 10 1.0 4 11.5 2 6 10 14 12 1.0 6 14.0 1 4 1 7 10 13 17 The above information provides general guidelines for the use of the Allan Block Wall system. The suitability of this information and its use for any specific job shall be determined by the user. Actual project details, designs and specifications should be obtained from a qualified professional engineer for each specific project. No provision or analysis for global stability. 16 ALLAN BLOCK GEOGRID SYSTEM The pre-engineered table below provides an accurate estimate for geogrid reinforcement. a To use the table follow these simple steps; 1� 1. Make sure the soil conditions at your site match the description in ALLAN BLOCK GEOGRID SYSTEM the top of the table TYPICAL SECTION 2. Select the site condition (Case A, B,or C)that most closely resembles your project site. OPTIONAL CAP BLOCK 3. Choose the wall height needed for your site and read across to find the number of grid layers, embedment length and grid ALLAN locations. BLOCK RID DESIGN PARAMETERS DRAINAGE FACTORS OF SAFETY ASSUMED WEIGHTS H FILL GEOGRIDS Sliding = 1.5 Earth Backfill = 120 lbs/cu.ft. Overturning =2.0 Filled weight of Grid Pullout = 1.5 ALLAN BLOCK= 120 lbs/cu.ft. DRAIN nl_E D3 Grid Rupture= 1.5 Onsite soils 120 lbs/cu.ft. AS NEEDED Z GENERAL SOILS Proper drainage provided. Cohesion = 0 B COMPACTED Grid meets ASTM D-4595 Bearing Capacity>2,500 psf ' `' GRANULAR GRID BASE Design Strength> 1,000 lbs/ft(LTADS) ie-Tensar UX1400, Miragrid 5T, Stratagrid 300, Fortrac 35/20-20 This table should be used for estimating grid quantities for projects which match the site and soil descriptions provided,and only for projects which use grid strengths of 1000 lbs/ft or higher. SOIL CONDITIONS o Soil Types: Uniform to well-graded silts, sandy and silty clays H B TOTAL No.OF Lgrid D1 D2 D3 D4 D5 D6 D7 SITE CONDITIONS ft ft GRID LAYERS ft NUMBER OF BLOCK COURSES ABOVE BASE CASE A 5 .6 2 4.0 2 5 Level slope above wall 6 .7 2 4.0 3 7 7 .8 2 4.0 3 7 8 .9 3 4.5 3 7 11 9 1.0 3 5.0 3 7 11 10 1.0 4 6.0 3 6 10 14 12 1.0 5 7.0 1 3 7 11 15 14 1.5 6 8.0 1 3 7 11 15 19 CASE B 5 .6 2 4.5 2 5 Surcharge above wall 6 .7 2 5.0 3 7 250 psf 7 .8 3 4.0 3 6 9 fITTi7 8 .9 3 6.5 2 5 9 9 1.0 4 7.0 2 5 9 12 10 1.0 5 7.5 2 5' 8 11 14 12 1.0 6 8.5 1 4 8 11 14 17 14 1.5 7 10.0 1 4 8 11 14 18 1 21 CASE C 5 .6 2 4.0 2 5 2 to 1 slope above wall 6 .8 2 4.5 3 7 2 7 .9 3 5.5 3 6 9 11 8 1.0 3 6.0 3 7 10 9 1.0 3 7.0 3 7 11 10 1.0 4 7.5 2 6 10 14 \P 12 1.0 5 10.0 1 5 9 13 17 14 1.5 7 12.0 1 4 8 11 14 18 21 The above information provides general guidelines for the use of the Allan Block Wall system. The suitability of this information and its use for any specific job shall be determined by the user. Actual project details, designs and specifications should be obtained from a qualified professional engineer for each specific project. No provision or analysis for global stability. 17 SYSTEM OPTIONS MASONRY REINFORCEMENT Allan Block Retaining Walls can be reinforced with the same proven techniques used for conventional masonry walls. This i method, often referred to as a "cantilevered wall", relies on a reinforced footing and vertical pilasters to counteract lateral earth pressures. These walls combine the natural stability of an Allan Block Wall with the tensile strength of the steel rods in pilasters, and the mass of soil resting on the heel of the footing to resist overturning. The design and construction of these walls follow the guidelines outlined in current ACI Standard and existing UBC design criteria (ACI 318-89), while factoring in the benefit of an inclined Allan Block wall. This reinforcement technique is particularly useful on sites where geogrids are not feasible or cost-effective. Physical site limitations such as lot lines, adjacent buildings, or mature trees may prevent the excavation required for grid reinforcement. Or the cost of additional excavation and backfill, (plus the cost of the grid) may prove too high. Masonry reinforcement provides an excellent alternative for those occasions. The specific footing size and steel location depends on site and soil conditions, and wall heights. Check the pre-engineered Masonry Chart on page 19 for design sample solutions. n� n� M ly, S BOND BEAM VERTICAL BARS DOWELS ZA REINFORCED FOOTING INSTALLATION Site Preparation — Excavate area at base of wall to ALLAN BLOCK MASONRY SYSTEM accommodate footing width (W), and to depth below final TYPICAL SECTION grade equal to footing thickness (T) and buried block (B). In heavy clay add a 6-inch layer of granular base below footing. Footing — Form and pour concrete footing according to size OPTIONAL CAP BLOCK and specifications. Include steel reinforcement as required. Follow NCMA TR-49 for details. ALLAN BLOCK Wall base — Install first course of Allan Block on top of VERTICAL BARS a footing per wall layout. Set blocks so that the dowels are BOND located at the backs of the block pockets. Fill all block cores H BEAM not containing vertical bars with granular fill, taking care to keep the "pilaster' cores clean. Backfill to lock in place and DRAINAGE compact. Set next course of Allan Block with seams in CONCRETE FILL running bond,and backfill in like manner. GROUT DRAIN TILE AS NEEDED Grout — Set additional courses to height of first bond beam. FOOTING Install bond beam blocks for full length of wall. Place vertical B REINFORCEMENT bars(sized and spaced according to specs) in hollow cores toA� ' top of footing and extend above top block at least 30 bar T CONCRETE FOOTING diameters. Place bond beam bars per specs. Fill all hollow cores and entire bond beam course with concrete grout. LiW Completion — Continue wall construction in similar lifts to top of wall. 18 ALLAN BLOCK MASONRY SYSTEM ah - The following information has been prepared according to current ACI Standards and Chapters 24(Masonry)and 26(Reinforced Concrete)of the 1991 Uniform Building Code(ICBG).The table below provides an accurate estimate for masonry reinforcement. To use the table follow these simple steps. 1. Make sure the soil conditions at your site match the description in the top of the table 2. Select the site condition (Case A, B, or C)that most closely resembles your project site. ALLAN BLOCK MASONRY SYSTEM 3. Choose the wall height needed for your site and read across to TYPICAL SECTION find the footing dimensions,vertical bar sizes and bond beam OPTIONAL CAP BLOCK requirements and locations. NOTE: Footing reinforcement design per local engineering requirements ALLAN BLOCK VERTICAL BARS DESIGN PARAMETERS BOND . ` FACTORS OF SAFETY ASSUMED WEIGHTS H BEAM Sliding = 1.5 Earth Backfill = 120lbs/cu.ft. DRAINAGE Overturning = 2.0 Filled Allan Block = 120lbs/cu.ft. CONCRETE FILL ALLOWABLE STRESSES Reinforced Allan Blk.= 135lbs/cu.ft. GROUT Masonry:f'm =3000 psi Reinforced Concrete = 150lbs/cu.ft. AIN TILE AS NEEDED Allan Block SOILS:Allowable soil bearing=2000 psf FOOTING Concrete:f'c =3000 psi Soil to footing friction=.55 B REINFORCEMENT' per ACI -301 Passive soil equivalent fluid IrA Reinforcement: pressure=300 pcf at toeT 6 t: CONCRETE FOOTING =40,000 psi#4 bars and buried depth. 60,000 psi#5&#6 bars GROUT: Per ASTM C-476 f'c=2500 psi Maximum aggregate size 3/8" 'DESIGN PER LOCAL ENGINEER STEEL BAR PLACEMENT:3"from back of block solid grout all cells with reinforcement. SOIL CONDITIONS Wiolllu.,l Soil Types: Uniform to well-graded fine sands, sandy silts SITE CONDITIONS H BOF B T W A VERTICAL BARS BOND BEAM BARS ft COURSES ft ft ft ft SIZE CELL SPACING SIZE I COURSE SPACING CASE A Level slope above wall 3'-11" 8 8" 1011 21-8" 8" #4 EVERY 7 CELLS (2) #5 EVERY 4 COURSES 5'-1" 10 8" 10" 3'-2" 8" #5 EVERY 7 CELLS 2 # 5 EVERY 5 COURSES 6'-3" 12 8" 10" 3'-9" 8" #5 EVERY 4 CELLS 2 #5 EVERY 6 COURSES T-4" 14 8" 10" 4'-4" 8" #5 EVERY 3 CELLS 2 #4 EVERY 5 COURSES 8'-6" 16 8" 10" 5'-0" 8" #5 EVERY CELL (2) #4 EVERY 7 COURSES 9'-6" 18** 10" 12" 5'-6" 8" #5 EVERY CELL (2)#4 EVERY 7 COURSES 4 CASE B Surcharge above wall 3'-11" 8 8" 10" 3'-2" 6" #5 EVERY 4 CELLS (2) #5 EVERY 6 COURSES 250 psf 5'-1" 10 8" 10" 4'-0" 6" #5 EVERY 2 CELLS 2 #4 EVERY 7 COURSES FITM 6'-3" 12 8" 10" 4'-9" 6" #5 EVERY CELL (2) #4 EVERY 7 COURSES T-4" 14 8" 10" 5'-4" 6" #5 EVERY CELL (2) #4 EVERY 7 COURSES 8'-4" 16** 10" 12" 5'-10" 6" #6 EVERY CELL 2 #4 EVERY 7 COURSES 9'-6" 18** 10" 12" 6'-8" 6" #6* EVERY CELL (2) #4 EVERY 7 COURSES CASE C 2 to 1 slope above wall 3'-11" 8 8" 10" 3'-2" 6" #4 EVERY 4 CELLS 2 #5 EVERY 5 COURSES 11 2 51-11, 10 8" 10" 4'-0" 6" #5 EVERY 4 CELLS 2 #5 EVERY 8 COURSES 6'-3" 12 8" 12" 4'-10" 6" #5 EVERY 2 CELLS 2 #4 EVERY 7 COURSES T-4" 14 8" 12" 5'-10" 6" #5 EVERY CELL 2 #4 EVERY 7 COURSES 8'-2" 16 12" 12" 6'-6" 6" #5 EVERY CELL 2 #4 EVERY 7 COURSES N 9'-0" 18** 16" 11211 7'-2" 6" #6 EVERY CELL 2 #4 EVERY 7 COURSES **Soil Bearing Exceeds 2,000 PSF * Requires Special Inspection Per UBC The above information provides general guidelines for the use of the Allan Block Wall system. The suitability of this information and its use for any specific job shall be determined by the user. Actual project details, designs and specifications should be obtained from a qualified professional engineer for each specific project. No provision or analysis for global stability. 19 SPECIFICATIONS ALLAN BLOCK PART I GENERAL and footing dimensions shown on construction drawings, 1.1 Scope or as directed by the site Engineer. Work includes furnishing and installing modular concrete block 2. Foundation soil shall be examined by the Engineer to retaining wall units to the lines and grades designated on the insure that the actual foundation soil strength meets or construction drawings and as specified herein. exceeds assumed design strength.Soil not meeting the 1.2 Applicable Sections of Related Work required strength shall be removed and replaced with A.Geogrid Wall Reinforcement acceptable material. B.Masonry Wall Reinforcement C. Base 1.3 Reference Standards 1. Base material shall be placed as shown on construction A. ASTM C90-75(1981 rev)Hollow Load Bearing Masonry drawing with a minimum thickness of six inches.Top of Units base shall be located to allow bottom wall units to be B. ASTM C140-75(1981 rev)Sampling and Testing buried to proper depths as per wall heights and Concrete Masonry Units specifications. j C. ASTM C145-75(1981 rev)Solid Load Bearing Concrete 2. Base materials shall be installed on undisturbed native I Masonry Units soils or suitable replacement fills compacted to 95%of j 1.4 Delivery,Storage,and Handling standard proctor. i3. Base materials shall be compacted to provide a level hard A. Contractor shall check the materials upon delivery to assure proper material has been received. surface on which to place first course of units.Compaction B. Contractor shall prevent excessive mud,wet cement,and shall be with a mechanical plate compactor to 95%of ` like material which may affix themselves,from coming in standard proctor. f contact with the materials. 4. Base materials shall be to the depth and width shown. C. Contractor shall protect the materials from damage.Dam- Contractor may opt for replacing top three inches of base aged material shall not be incorporated into the project. with an unreinforced concrete topping.When masonry reinforcement technique is used,check footing design in that section for further details. PART 2 RETAINING WALL 2.1 Materials D. Unit Installation 1. First course of concrete wall units shall be placed on the A.Concrete Units 1. Masonry units shall be Allan Block Retaining Wall units as prepared base with the raised lip facing out and the front produced by Licensed Manufacturer. edges tight together.The units shall be checked for level and 2. Concrete wall units shall have minimum 28 day compressive alignment as they are placed. strength of 3,000 psi in accordance with ASTM C-90.The 2. Insure that units are in full;contact with base.Proper care concrete shall have adequate freeze-thaw protection with an shall be taken to develop straight lines and smooth curves on average absorption rate of five percent. base course as per wall layout. 3. Exterior dimensions shall be uniform and consistent. 3. All cavities in and around the base row shall be filled with Maximum dimensional deviations shall be one-half inch "base material"and compacted.Backfill front and back of (not including textured face).Units are required to have an entire base row to firmly lock in place.Check again for level average facial area of.75 sq..ft. and alignment.All excess material shall be swept from tops of 4. Retaining wall units shall provide a minimum of 100 pounds units. total weight per square foot of wall face area.Fill contained 4. Install next course of wall units on top of base row. within the units may be considered 80%effective weight. Position blocks to be offset from seams of blocks below. 5. Exterior face shall be textured.Color as specified by Perfect"running bond"is not essential,but a three-inch owner. average minimum offset is recommended.Check each block for proper alignment-and level.Fill all cavities B. Base Material 1. Base material shall consist of compacted sands,gravel,or in and to an 8"depth behind block with"drainage.fill" 1 Backfill remaining space behind second course with concrete as shown in the construction drawings.A minimum of six inches of compacted base is required. onsite soils and compact to 95%of standard proctor. 5. Lay up each subsequent course in like manner.Repeat C. Drainage Fill 1. Fill material for unit cores and for drainage behind wall procedure to the extent of wall height. shall consist of free-draining,granular material.Gradation 2.3 Water Management shall include material to 3/8 inch minus with fines limited to A. Avoid retaining wall design and installation which would permit 5pooling and collection of surface runoff above wall. %passing#200 sieve and less than 50%passing#40 j sieve. B. Adequate provisions to be made to control surface runoff and 2. A minimum of 8 inches of drainage fill must extend behind direct around wall ends.Provide swales above and below wall the wall to within one foot of the final grade.Cap backfill as permissible to accommodate. with impervious material. C. Retaining Wall design and installation to provide maximum lateral drainage at site as allowed by existing site conditions. E.Backfill 1. Material shall be native material unless otherwise specified D. Provide for additional drainage relief behind retaining walls in the drawings.When using geogrid for slope reinforcement, above 5 feet in height.Install 4-inch diameter perforated drain soils used to backfill geogrid must comply with standards tile at wall base and above grade at base of wall.Install tee- set by grid manufacturer's guidelines. fittings and outlets through wall surface at no greater than 20 2. Where additional fill is required,contractor shall submit feet on center. sample and specifications to the Engineer for approval. E. Provide for adequate mulch or vegetative ground cover above and surrounding retaining wall to prevent excessive soil 2.2 Retaining Wall Installation erosion. A. Excavation F. 1. Contractor shall excavate to the lines and grades shown Contain sources of concentrated water flow such on the construction drawings.Contractor shall use caution scuppers,drains and valleys,parking lots,etc...and route roof not to over excavate beyond the lines shown,or to disturb around wall accordingly. the base elevations beyond those shown. B. Foundation Soil Preparation 1. Foundation soil shall be excavated as required for base 20 SPECIFICATIONS REINFORCEMENT I GEOGRIID PART 1 GENERAL 1.1 Scope D. Geogrid shall be laid at the proper elevation and orientation Work includes furnishingand installing as shown on the construction drawings or as directed by the g geogrid reinforcement, Engineer. wall fill,and backfill to the lines and grades designated on the E. Correct orientation(roll direction)of the geogrid shall be construction drawings and as specified herein.Also included is the furnishing and installing all appurtenant materials re- verified by the contractor. F. Follow manufacturers guidelines relative to overlap require- required for construction of the geogrid reinforced soil retaining ments of uniaxial and biaxial grids. wall as shown on the construction drawings. G. Location and placement of the geogrid is as shown on the 1.2 Applicable Sections of Related Work drawings.The relative position of the geogrid layers to the A. Section 1:Allan Block Modular Retaining Wall Units. height above finished grade must be maintained regardless 1.3 Reference Standards of the number of units which are placed below finished A. See specific geogrid manufacturers reference standards. 1.4 Delivery,Storage,and Handling grade. A. Geogrid 3.4 FIII Placement and Backfill Placement A. Wall fill material shall be placed in lifts and compacted as 1. Contractor shall check the geogrid upon delivery to assure that the proper material has been received. Specified under Section:Modular Concrete Retaining Wall 2. Geogrid shall be stored above-20 degrees F. Systems. B. Backfill shall be placed,spread,and compacted in such a 3. Contractor shall prevent excessive mud,wet cement, manner that minimizes the development of wrinkles in and/or epoxy and like materials which may affix themselves to the gridwork,from coming in contact with the geogrid movement of the geogrid. material. g g C. Only hand operated compaction equipment shall be allowed 4. Rolled geogrid material may be laid flat or stood on end within 3 feet of the wall face. for storage. D. Backfill shall be placed from the wall rearward to insure that PART 1 GRID MATERIALS the geogrid remains taut. E. Tracked construction equipment shall not be operated 2.1 Definitions directly on the geogrid.Minimum backfill thickness of 6 A. Geogrid products shall be of high density polyethylene or inches is required prior to operation of tracked vehicles over Polyester yarns encapsulated in protective coating the geogrid.Turning of tracked vehicles should be kept to a specifically fabricated for use as a soil reinforcement minimum to prevent tracks form displacing the fill and material. damaging the geogrid. B. Concrete retaining wall units are as detailed on the drawings F. Rubber-tired equipment may pass over the geogrid re- and are specified under section:Retaining Wall Units. enforcement at slow speeds,less than 10 MPH.Sudden C. Wall fill is a free draining granular material as defined in braking and sharp turning shall be avoided. section:Modular Concrete Retaining Wall systems as G. The backfill shall be compacted to achieve 95%standard "Drainage Fill"behind the wall. proctor.Soil tests of the backfill material shall be submitted to D. Backfill is the soil which is used as fill for the reinforced soil, the on-site engineer for review and approval prior to place- mass. ment of any backfill These soil tests shall be performed by E. Foundation soil is the insititu soil. an independent testing agency,or approved on-site lab. 2.2 Products The test results shall be given to the on-site engineer as A. Geogrid shall be the type as shown on the drawings having soon as possible after testing.The contractor is fully respons- the property requirements as described within the ible for achieving the specified compaction requirements. manufacturers specifications. The on-site engineer may direct the contractor to remove and 2.3 Acceptable Manufacturers correctly replace any soil found to be not in compliance with A. A manufacturers product shall be approved by the engineer these specifications. prior to bid opening. PART 3 EXECUTION MASONRY 3.1 Foundation Soil Preparation A. Foundation soil shall be excavated to the lines and grades The design and construction of a Reinforced Masonry Wall System as shown on the construction drawings or as directed by the shall comply with Sections B through D and the provisions of Engineer. chapters 23 and 24 of the 1991 UBC. B. Foundation soil shall be examined by the Engineer to assure that the actual foundation soil strength meets or exceeds assumed design strength. TECHNICAL SUPPORT C. Over-excavated areas shall be filled with approved compacted backfill material. Engineering support for projects that fall beyond the scope of D. Foundation soil shall be proof rolled prior to fill and geogrid these guidelines,contact ALLAN BLOCK CORPORATION at placement. 1-800/899-5309 for assistance. 3.2 Wall Erection A. Wall erection shall be as specified under Section l:Retaining Walls. 3.3 Geogrid Installation A. Install ALLAN BLOCK wall to designated height of first grid layer,backfill and compact behind wall to depth equal to designed grid length. B. Cut geogrid to designed embedment length(Lgrid)and lay behind wall with cut edge of grid on top of ALLAN BLOCK to back edge of lip. Extend to back of slope. C. Place next course of ALLAN BLOCK on top of grid and fill block cores with drainage fill to lock in place. Remove slack in grid and stake to maintain tension. 21 ♦ A� The information in this yr: manual has been carefully compiled by the ALLAN ♦ '�I BLOCK CORPORATION and to the best of our knowledge accurately represents ALLAN BLOCK � product use in the applications which are j illustrated. Final I determination of the suitability of any information .1T w . or material for the use contemplated and its manner of use is the sole i responsibility of the user. 1r:i*.• ti ?Y, � m?f - -t. i THE ALLAN BLOCK WARRANTY ALLAN BLOCK INC., warrants to its customers that each ALLAN BLOCK will meet or exceed current ASTM standards on compression,strength,and absorption for a period of up to 20 YEARS from the date of shipment. If an ALLAN BLOCK does not meet these standards, and as a result causes a retaining wall to fail.ALLAN BLOCK INC.will, upon notification in writing from from the customer,and verification of such cause,ship the appropriate number of replacement units to the customer's address,free of charge. Neither ALLAN BLOCK INC. nor the manufacturer shall have any further obligations under this warranty,either for replacement costs or any other costs associated with the reconstruction of the customer's wall. This warranty does not apply to blocks which are damaged upon delivery, blocks which are affected by unusual sight or soil conditions, blocks not manufactured in accordance with manufacturer's Product Control; Standards, the design or structure of any ALLAN BLOCK walls,or any blocks not installed in strict accordance with ALLAN BLOCK INSTALLATION GUIDELINES. Warranty information shall be sent to Allan Block,Inc., 7400 Metro Blvd.,Suite#185,Edina,MN 55439.Phone 612/835-5309. 24 � v , MASSACHUSETTS UNIFORM APPLICATION FOR PERMIT TO 00 GASFITTING � (Print or Type) NORTH ANDOVER Mass. Date � _ Building Location Zp7 Permit # / J'6r" Owners Name �dl,,.</ 69,026 ��b • New 'PI Renovation Replacement Plans Submitted �] y FIXTURES N 9(�, z vs rn Q d V 47 f' S N LU O W < ¢ a 0 ' Q Z h d W W 1- W O 0. Q W Q w W-e � r F- sn > 4 N cc N d V w at 4 cc O In to W ty1 cn W J Z < a s a a W f. w U s c2 is a �. z P z Z 4 W a Q G Q m O Z taJ O N Z Q Ll > C W 2 < O O W O tat E- O 0 Cr > Q a t- O SU1j-8SMT, e BASEMEMT ISTFLOOR I G1 2ND FLOOR 3Rn FLOOR 4TH FLOOR 5TH FLOOR 6TH FLOOR TTI! FLOOR LLT_H FLOOR (Print or Type) _ Check one: Certificate Installing Company Name Corp. Address Partner. Firm/Co. Business Telephone:;!!�;De 772-' 7722- , Name of Licensed Plumber or Gas Fitter Aele Insurance Coverage: Indicate the type of insurance coverage by checking the appropriate box: Liability insurance policy [�? Other type of indemnity Q Bond E( Insurance Waiver: I , the undersigned, have been made aware that the licensee of this application does not have any one of the above three insurance coverages. Signature of owner/agent of property Owner 0 Agent 1 hereby certify that all of the details and information 1 have submitted (or entered)in above application are true and accurate to the best of my knowledge and tttat all ptumbing Work and lnstaUations petfotmed under Permit itteed for this application willbe in compliance with all pertlneat provisions of tho Massachusetts State Gas CUde and Chapter 142 of tho General Laws. By TYPE LICENSE: Plumber Title Gasfitter Signature of Licensed Master Plumber or Gasfitter City/Town: JourneymanZd L�D APPROVED (OFFICE USE ONLY) License Number Date... ..'... ..f....... ,,Of?TN TOWN OF NORTH ANDOVER Of t,.co ,e 14.0 0 PERMIT FOR GAS INSTALLATION, SSACHUSEtty vJ This certifies that . . . . . . . . ... . . . has permission for gas installation . . . . . . ... . . . in the buildings of . . ,. tf ..r%' . j. . . . . . . . . . . .... . . . at .� :,r. . �� . . "�!fr•. �-(/. .3/`­ ., North Andover, Mass. Fee. Z. . . . . Lic. No."?t,i.. .t.) . . . . . . . . . . . . . . . . . . . . . . . . . . GAS INSPECTOR WHITE:Applicant CANARY:Building Dept. PINK:Treasurer GOLD: File