HomeMy WebLinkAboutMiscellaneous - 19 BEAVER BROOK ROAD 4/30/2018 (2) Commonwealth of Massachusetts
Title 5 Official Inspection Form
Not for Voluntary Assessments
r` Subsurface Sewage Disposal System Form
M
A. Certification (cont.)
19 Beaver Brook Road
Property Address
North Andover MA 01845
City/Town State ZipCode
Ron Novello 9/25/07
Owner's Name Date of Inspection
D)System Failure Criteria Applicable to All Systems:
You must indicate"Yes"or"No"to each of the following for all inspections:
Yes No
❑ ® Backup of sewage into facility or system component due to overloaded or
clogged SAS or cesspool
❑ E Discharge or ponding of effluent to the surface of the ground or surface waters
due to an overloaded or clogged SAS or cesspool
❑ ® Static liquid level in the distribution box above outlet invert due to an overloaded
or clogged SAS or cesspool
❑ Z Liquid depth in cesspool is less than 6"below invert or available volume is less
than '/2 day flow
❑ ® Required pumping more than 4 times in the last year NOT due to clogged or
obstructed pipe(s). Number of times pumped:
❑ ® Any portion of the SAS, cesspool or privy is below high ground water elevation.
❑ ® Any portion of cesspool or privy is within 100 feet of a surface water supply or
tributary to a surface water supply.
❑ ® Any portion of a cesspool or privy is within a Zone 1 of a public well.
❑ Z Any portion of a cesspool or privy is within 50 feet of a private water supply well.
❑ ® Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet
from a private water supply well with no acceptable water quality analysis. [This
system passes if the well water analysis, performed at a DEP certified
laboratory,for coliform bacteria and volatile organic compounds
indicates that the well is free from pollution from that facility and the
presence of ammonia nitrogen and nitrate nitrogen is equal to or less
than 5 ppm, provided that no other failure criteria are triggered.A copy of
the analysis must be attached to this form.]
Yes No
❑ ® The system fails. I have determined that one or more of the above failure
criteria exist as described in 310 CMR 15.303, therefore the system fails. The
system owner should contact the Board of Health to determine what will be
necessary to correct the failure.
9.25.07_19BeaverBrookRoad_NorthAndover.doc•11/2004 Title 5 Official Inspection Form:Subsurface Sewage Disposal System
Page 5 of 16