Loading...
HomeMy WebLinkAboutMiscellaneous - 19 LITTLE ROAD 4/30/2018 / 19 LITTLE ROAD J 2101096 00.0 l Date..!!? �2 41................. TOWN OF NORTH ANDOVER PERMIT FOR WIRING SSACHU This certifies that � �-�.,,..� .. ... ............ has permission to perform ...... .......vof... / ... wiring in the building of.........Lqfv.!?.z.............................................................................. at ..... ......L.A.-lo........�2-4......................................m....IN North Andover,Mass. ..................... ........... . Fee.....�25.7.......Lic.No. .......... .... ................ ELECTRICAL INSPECTOR Check# 129 82 ( onsmonwea&o f Mamac4ujetts Official Use Only ii Permit No. cc/�� � e1.Jepartmerct ol.�` cc77 ire�ervicea Occupancy and Fee Checked BOARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07] leave blank APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Cod EC),5271 CMR 12.00 (PLEASE PRINT IN INK OR TY E ALS INFORMATION) Date: City or Town of: I', ove—r To the Inspector of Wires: By this application the undersigned gives notice of his or he intention to perform the electrical work described below. Location(Street&Number) ��� _ Owner or Tenant Telephone No. (oil/<�a37 Owner's Address NW+k Is this permit in conjunction with a building permit? Yes Q No ❑ (Check Appropriate Box) Purpose of Building Mount array to roof Utility Authorization No. Existing Service Amps / Volts Overhead ❑ Undgrd❑ No.of Meters New Service Amps / _ Volts Overhead❑ Undgrd ❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Install solar PV array S A,�j e� S L'."A\ [-UJ Completion o the followingtable maybe waived by the Inspector of Wires. p, No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ n- ❑ o.of Emergency Lighting rnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection an Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices g Tons g No.of Waste Disposers Heat Pump Number Tons KW No.ofSelf-Contained p Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local❑ Co n ecti l ❑ Other Connection No.of Dryers Heating Appliances KW SecuritySystems:* No.of Devices or Equivalent No.of Water KW No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications No. f Devices or Equivalent OTHER: G Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: 0 (When required by municipal policy.) Work to Start: / 3 /(v Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE OV RAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE n BOND ❑ OTHER ❑ (Specify:) I certify,under the pains andpenalties ofperjury,that the information on this application is true and complete. FIRM NAME: Northeast Electrical LIC.NO.:A16864 Licensee: Clifford George Signature �. LIC.NO.: (If applicable,enter "exempt"in the license number line) Bus.Tel.No..781.272.4899 Address: 1 North Ave Suite A,Burlington,MA 01803 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent. Owner/Agent PERMIT FEE: $ Signature __ Telephone No. c rf � '�' ,. PROJECT DESCRIPTION Contractor: THIS ROOF MOUNTED PHOTOVOLTAIC (PV) SYSTEM IS TO BE INSTALLED AT THE SINGLE-FAMILY DWELLING IN NORTH ANDOVER, MASSACHUSETTS. REVOLU.SSUN THE ENERGY PRODUCED BY THE PV SYSTEM SHALL BE INTERCONNECTED WITH THE UTIITY GRID THROUGH THE EXISTING ON-SITE ELECTRICAL EQUIPMENT VIA ---1..— A SUPPLY SIDE CONNECTION IN THE MAIN SERVICE PANEL. THIS PROJECT DOES NOT INCLUDE STORAGE BATTERIES. I NORTH AVENUE BURLINGTON,MA 01803 SHEET INDEX SCOPE OF WORK CONSTRUCTION NOTES P:(781)270-6555 T 1.0 COVER (1 5)PV MODULES(TOTAL: 264 SQ. FT.) 1.)CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO w .Ma55achu5etts.Revotusun.com Al.0 51TE PLAN (1) 5.0 kW INVERTER INITIATING CONSTRUCTION. A I.I ROOFS#1, 2, 3, 4: PV LAYOUT (I 5)SOLAREDGE POWER OPTIMIZERS 2)CONTRACTOR 5HALL REVIEW ALL MANUFACTURER INSTALLATION DOCUMENTS PRIOR TO INITIATING CONSTRUCTION. A2.0 MOUNTING ff RACKING METHOD (30)ATTACHMENT POINTS @ 48"O.C. MAX. 3.)ALL EQUIPMENT SHALL BE LISTED BY U.L.(OR EQUAL)AND J5TED FOR E 1.0 ELECTRICAL DIAGRAM (1)AC DISCONNECT, 240 VAC, NEMA 3R IT5 SPECIFIC APPLICATION. 4.)ALL EQUIPMENT 5HALL BE RATED FOR THE ENVIRONMENT IN WHICH IT ENORTH E2.0 SAFETY PLACARDS (1)LOAD CENTER, 240 VAC, NEMA 1 15 INSTALLED. RE51DENCE DI.0 MODULE DATA SHEET (1)PV METER, 240 VAC, NEMA 3R 5.)ALL EQUIPMENT 5HALL BE INSTALLED IN ACCORDANCE WITH THETLE ROAD MANUFACTURER'S INSTALLATION INSTRUCTIONS. VER,MA01845 D2.0 INVERTER DATA SHEET 02_16_0022 pp 6.)ACCESS TO ELECTRICAL COMPONENTS OVER 150 VOLTS TO GROUND DG.0 OPTIIMZER DATA SHEET 5HALL BE RESTRICTED TO QUALIFIED PERSONNEL. Protect Details: 7.)ALL CONDUCTORS 5HALL BE COPPER,RATED FOR GOO VOLT5 AND 4.91 kWstc,5.00 kW AC SITE SPECIFICATIONS 90°C WET ENVIRONMENT.UNLESS OTHERWISE NOTED. OCCUPANCY CATEGORY: II 8.)WHERE SIZES OF JUNCTION BOXE5,RACEWAYS,AND CONDUITS ARE NOT SPECIFIED,CONTRACTOR 5HALL SIZE THEM ACCORDING TO Engmeenng Approval: DE51GN WIND SPEED: 100 MPH APPLICABLE CODE5. PARTS LIST EXPOSURE CATEGORY: B 9.)PV MODULE FRAMES 5HALL BE BONDED TO RACKING RAIL OR BARE COPPER G.E.C.PER THE MODULE MANUFACTURER'S LISTED INSTR SHEE Quantity De5cr1ptlon GROUND SNOW LOAD: 50 P5F T. 15 PV Module 10.)PV MODULE RACKING RAIL 5HALL BE BONDED TO BARE COPPER G.E.C.VIA WEEB LUG,IL5CO GBL-4DBT LAYINLUG,OR EQUIVLENT LISTED 5 Power Optimizer LUG. GOVERNING CODES 1 1.)GROUNDING ELECTRODE CONDUCTOR(G.E.C.)5HALL BE CONTINUOUS 30 QMPV C1a551c Comp Fla5hmg 2014 NATIONAL ELECTRICAL CODE AND/OR IRREVERSIBLY 5PLICED/WELDED. 30 Umrac L-Foot 780 CMR, 8th EDITION 12.)ALL JUNCTION BOXES,COMBINER BOXES,AND DISCONNECTS 5HALL BE INSTALLED IN AN ACCESSIBLE LOCATION. 3015/1 6"Lag Screw UNDERWRITERS LABORATORIES(UL)STANDARDS 13.)ROOF ACCESS POINTS 5HALL BE AT A STRONG POINT ON THE 97 Feet of Unlrac SunFrame Rall OSHA 29 CFR 19 10.269 BUILDING AND NOT REQUIRE THE PLACEMENT OF LADDERS OVER LL EXNERIO DE5CRIFTIORFV1510N5 N DATE REV 14.)WORKING SPACE AROUND ELECTRIAL EQUIPMENT 5HALL COMPLY WITH ORIGINAL 12//2015 A - NEC 110.26 �l It � rO - � /�) �/"1 `v5�. � �k;,� CJ�� I '�•-� _.+. r �-y�,_ c �•S � —• ! !]�� ..8.. U II o � I '^ �„ "�` "V-/ �I`l. 1�'� � � ,•y� '�.,t �� uF .�..�.V J'`l. Sheet Title: COVER � � �' ' ( <y \.,� ax S / .� ®?• T`a �/ r,,, L 5heet Number: t� �.°a . ®^ '• \ ,mow �° 9i a ` ,h ' Sheet Srze: i s� ANSI B - 17" x I I" 0DESIGN t DRAFTING BY% /1 . `x • /�/ e,4�L I I O / ::w,�,�ff /�� f 4 �° :.r Y -� „✓ VJOEL HORST /� �� ,,�,i� .;.�,e •� G�.�a 1 �� ,��.: --PISOLAR PARCEL MAP AERIAL MAP VICINITY MAPReviewed#Approved by: n n PROJECT LOCATION s EH Contractor: W REVOLU(SUN I NORTH AVENUE BURLINGTON,MA 01803 140° P:(781)270-6555 www.Massachusettg.F-voW5un.com r PROPERTY — LINEpPV5U[3-APPAY eC — ———— Pro t LOPEZ RE5IDENCE I PV LOAD CENTER Y# 19 LITTLE ROAD NORTFI ANDOVER,MA O 1 845 PV METER Y#2 JOB#:MA02_1 G_0022 AC DISCONNECT INVERTER W/DC DISCONNECTAY#3 Project Details: UTILITY METER MAIN SERVICE PANEL Y#4 I 4.91 kWstc,5.00 kW AC I I Eng,neermg Approval: I I � I I rn I r� o I � � I 3/4"EMT = 37°PITCH I JUNCTION BOX O 35'-7" I OPTIMIZERS REVISIONS UNDER PV MODULES = ORIGINAL ION 1214,2015 uv 37°PITCH I I VENTS I I � I CHIMNEY Sheet Title: I SITE PIAN — 5 1'-5" i heel Number: I / Al .O � beet Slze: DRIVEWAY i ANSI B - 17"x l l" ------ ---------------- 1151G LYMAN ROAD JOEL 6 DRAF ING BY: noRsr CCppd�e�Op w C�G�S CAU gUpo J SEPI OLA I—5 ft—I~10 ft 20 It Reviewed 4 Approved by: SCALE: I"= I O' EH Contractor: REVOLU(SUN �en�r.sma,<ar.�lar. 17-14a'I 1 1 NORTH AVENUE 24"TYP. I 3 54 BURLINGTON,MA 01803 CHIMNEY 230° II 140° P:(781)270-6555 II _II www.MavvAwd5.Revok5un.com it VENTS 24"TYP. II Ii II I -T, 37°�PIrcH II I II III I' I II I II 4'MAX. li I FLASHING II 4'MAX. I II II I I I I Proect: II II I' �I it II h PV MODULE TYP. II I II I L 19 L RESIDENCE I I II (I I ( I I 19 LITTLE ROAD NORTH ANDOVER,MAO 1845 II I I ' RAFTER I I I I JOB#:MA02_16_0022 II IF RACKING RAIL I PV MODULE TYP. II II III III II IiI II 4II IIIII II hIII IIII 4 III, II ProectDetails: fLA5HING 491 kWs c,5.00 kW ACRAFTER RACKING RAIL II II II I II I II II �I �I I II II II I II 6'-1 041 II II I II II II II I II I II I II II II II I I II Englneenng Approval: II II I I I I II I 11 II II I 37°PITCH I _� _LL II II �l I It II II I II II II I j II 1 II ; SAVE ROOF#1F-71 2 ft-�---4 ft�- 8 ft -� ROOF#2 2 ft--I-4 ft��8 ft SCALE: I"=4' SCALE: 1"--4' �24"TYP. 4'MAX. REVISIONS 0-I 0-7'1' 1' D[SCPJPTiON DATC ItEV 4 RIDGE oRwwAL I2PI/2015 A R4'MAX. IDGE II it II PV MODULE TYP. 230° I 37°PITCH II I ( I _ I 40' I II I II II II II I II II RAFTER I I 24"TYP. II II II II II I ee II I 1 II I II I I I I II II I I I I I I ht Title: FLASHING II tl Il II I II II I I I I II II II II II r, II I t 1; PV MODULE TYP. ROOFS#1, 2, 3, 4 RACKING RAIL II II II I� I� I� II II II I II RAFTER P POUT II II II 20°PITCH II �I �I I �I heet Number: ffi II y I II I I I I FLASHING A I . I II II SAVE I�I� I I Sheet Srzc: II Y I RACKING RAIL ANSI B - 17"x I I" II I ESIGN t DRAFTING BY: SAVE JOEL r+oRsr Gpq 00 �Op 6'-104' pop�uppnuooeo I pppopoQoCaoq 0'-32° ISO /R f-2 It-J--4 ft�- 8 ft _� 2 ft-}�4 ft�- 8 ft --� Reviewed L Approved b ROOF#3 ROOF#4 (-� ppr Y: SCALE: 1"=4' 3 SCALE: I"=4' EH STRUCTURAL CALCULATIONS STRUCTURAL CALCULATIONS I I I I I I I I I I Contractor: A5CE 7-10.Ch 30,PART 2 A5CE 7-1 O,Ch 30,PART 2 DE51GN CRITERIA DESIGN CRITERIA I I I II I I I I I REVOLU(SUN AVERAGE ROOF HEIGHT(FT): 25 AVERAGE ROOF HEIGHT(FT): 25 smatter caar ROOF SLOPE: 370 ROOF SLOPE: 20' r--I-I--' I I r--I-I--- I ( r--I-I--- uearwr I I I EXPOSURE CATEGORY: B EXPOSURE CATEGORY: B RAFTER 121 TYP_�( I I I I I I t I NOPTH AVENUE ADJUSTMENT FACTOR(T): 1.00 ADJUSTMENT FACTOR(T): I.00 I I I I I I I I I I j BURLINGTON,MA 01803 TOPOGRAPHIC FACTOR(Kn): 1.00 TOPOGRAPHIC FACTOR(Kn): I.00 I I I I I P:(781)270-6555 DE51GN WIND 5PEED(MPH): 100 DE516N WIND SPEED(MPH): 100 PV MODULE J -- _- -- -- -- -- www.Ma55achu5ett5.Revoiu5m.com REDUCED SNOW LOAD(LE/FT'): 17.06 REDUCED SNOW LOAD FTc, 24.71 S -ARRAY#1 CALCULATIONS 5UB-ARRAY#3 CALCULATIONS UB (L& EFFECTIVE WIND AREA(W): 10 EFFECTIVE WIND AREA(FTW): 10 1 GI'MAK.I I 4-MAK' I I I I I I WIND ZONE: 2 WIND ZONE: 2 ARRAY DEAD LOAD(LEUFT): 2.98 ARPAY DEAD LOAD(LEYFTz): 2.98 PRESSURE DOWNWARD(LWT'): 19.9 PRE55URE DOWNWARD(L4'FT'): 12.5 I I I I I I I I I I Project: PRE55UKE UPWARD(LL/fft;: -25.5 PRESSURE UPWARD(LB/FTz): -34.7 I I I I I I I I I I LOPEZ RESIDENCE DOWNWARD POINT LOAD(LB): 358 DOWNWARD POINT LOAD(LB): 433I I I I I I I I I I TH 1 9 LITTLE ROAD UPWARD POINT LOAD(LB): 200 UPWARD POINT LOAD(LB): 281 NORO5 ANDOVER,MAO 1845 I I I I I I I I I I JOB#:MA02_I 6_0022 SUB-ARRAY#2 CALCULATIONS EFFECTIVE WIND AP.EA(FT'): ID I I I I I I I I I I Project Details: WIND ZONE: 2kWstc,5.00 kW AC ARRAY DEAD LOAD(LEJFTz): 3.05 PRE55URE DOWNWARD(LE/PT'): 19.9 Engineering Approval: PRESSURE UPWARD(LBrFTz): -25.5 I I I I I I I I I DOWNWARD POINT LOAD(LB): 269 I I I I UPWARD POINT LOAD(LB): 150 I 51-115-ARRAY#4 CALCULATIONS I I I I I I I I I I EFFECTIVE WIND AUA(FTz): 10 L-FOOT r I II II I II I II II I I WIND ZONE: 2 RACKING RAIL ARRAY DEAD LOAD 2.93 PRESSURDOWNWARD(Lwrl): 199 PRESSURE UPWARD(L6TTz): 5III III Ir - -I1--� DOWNWARD POINT LOAD(LB): 447 PL.A5HING- -J 2 UPWARD POINT LOAD(LB): 251 I I I I I I I I I I REVISIONS 6'n+— G'. 32 in +- DCSCRIPriON DATE REV MOUNTING PLAN VIEW oR1Gwu 12/4/2015 A SCALE: I"= 16" / UNIRAC CAP STRIP Iry MODULE NIRAC SUNFRAME RAIL hest Titie: } UNIRAC LFOOT MOUNTING W CMOUNT RACKING METHOD - CLASSIC V551C COMP MOUNt ' �.- Number: P QOOf - (,,.\„ COMPOSRION \ AWMINUMFIASNNIG A2.0 COMZA'0' -� ROOF / beet Size: ANSI B - 17"x I I" /yyb T \ S/IN'552-1/1/W SCREW JOEL t DRAFTING BY: /)/ IN ED W1 THPfAD EMUNK M I(ORICM! JOEL YIORST SEALED W/CHEMUNK M I(OR EOW V.) ,! �C:ppo��CCCCOp > // GCC:U�UUDODG / MOUNTING METHOD MOUNTING DETAIL �I 5CALE: I"= 12" 5CALE: I"=6" SC OL I--Gin-ice 1 2.. 24 m _� �-�/ // 3'n G m + 1 2,n Ke—ed 6 Approved by: j/ Eh --EQUIP.GROUNDING CONDUCTOR -'CIRCUIT CONDUCTOR =FUSE��=CIRCUIT BREAKER (N)=NEW EQUIP. (E)-EXISTING EQUIP. LI -LINE (BLACK) L2 -LINE 2(RED) -NEUTRAL M'hITE) ©-GROUND(GREEN) E0-POSITIVE(RED) E]-NEGATIVE(BLAC Contractor: Array Configuration PV Module Specifications Inverter Specifications Power Optimizer Specifications AC System Summary I�� System:4.905 kWstc,5 kW AC Model Number: SunPower E20.327 Model Number: Solar Edge SES000A-US Model Number: Solar Edge P400 NOMINAL SYSTEM VOLTAGE: 240 VOIts AC R EVOLU(SUN dearer.PmRnGr.polar. Total PV Module Qty:15 Weight: 41.0 lbs Power Rating: 5.00 kW AC Max Input Power: 400 Watts MAX CURRENT PER 690.8(A): 21 Amps Inverter l.D.N Inv## Dimensions: 61.39x41.18x1.81 (in) Nominal Voltage: 240 Volts AC Max Voc: 80 Volts DC MAX CURRENT PER 690.8(8);l 26 Amps I NORTH AVENUE Inverter AC Power(kW): 5.00 Module Power @STC: 327 Watts Max Output Current: 2LO Amps Output Current: 15 Amps BURLINGTON,MA 01803 P:(781)270-6555 PV Power(kWs tc): 4.91 Voc(open-circuit Voltage): 64.9 Volts DC CEC Weighted Efficiency:98.0% Output Voltage: 60 Volts DC wvwv.Massachusetts.f:evduslm.com Module Total Qty: 15 1 Vmp(max-power Voltage): 54.7 Volts DC Maximum DC Voltage: SW Min.String Length: 8 Inverter DC:AC Ratio 0.98 Isc(short-circuit current): 6.46 Amps Inverter Qua ntity: 1 Max.String Length: 25 Stri ng Qty: 1 imp(max-power current): 5.98 Amps Max.String Power: 5250 Watts Q String Length: 15 Mfr Voc Temp Coefficient: -0.27 %/"C j Max Open Circuit Voltage 500.0 Prgect: a Operating Voltage: 350.0 LOPEZ RE51DENCE 2 19 LITTLE ROAD Max Short G Fault Current 17.5 NORTH ANDOVER,MA 01845 Operating Current: 14.0 JOB#:MA02_1 G_0022 Stri IT g Qty: 0 [rqj-t Dctads: TO UTILITY GRID ry String Length: 0 4.91 kW5tc,5.00 kW AC j Max Open Circuit Voltage 0.0 1 Operating Voltage: 0.0 (E)BI-DIRECTIONAL Z -N BA5EMENT I BLDG EXTERIOR l'tALL-- . UTILITY METER Englneenng Approval: Max Sh Ort Circuit Current 0.0 I (N)AC DISCONNECT I-PHA5E,240 V Operating Current: 0.0 SOD D222NRe __ _ POINT OF INTERCONNECTION (N)PV LOAD CENTER (N)PV kVVH METER I Ne0VAc.60A -ON ROOFTOP I IN BASEMENT--- 50 D nOMB16L125 UTIUT,GRADE R uL u5T[D (N)LINE 51DE TAP zaO vu,'zs A 240 vAC,1 W A 15urtA5tE Fac use A5 I ER NEC 240.2 I(B)(I)4 705.12(A) L U5T ET ( sexvlce EOUIPMexr I LENGTh OF TAP CONDUCTORS (N)INVERTER NEMA 3K UL u5TeD 30 A 511ALL NOT EXCEED 10 FT 501AREDGE SESOOO 5 iouTPLT:5.0I,w.2q0 vAc,21 A (E)MAIN SERVICE DISCONNECT 9B 0%CEC-w IGnTfO ffflClfN I 100 A,240 V,2-P MP.3P.UL N5TED.INTERNAL GFDI x AFCI UNGROUNDED,TRANSFORMfRI£55 - - -I I 100 A E)BUS DABS:100 A PV MODULI (N)JUNCTION BOX,eou1PPED wlTn PAnD SnUTDoww NEMA L u5TeD uL usreD Dc- G 30 A I -- DISCONNECT (N)AwG Pn EnaN I (E)MAN SERVICE PANEL SOLAR Gf POWER OPTIMIZER E10xD1NG JUMPER G D Pg00.60 IDC.15A • • I REVISIONS 90.6%WYIGnifD fFf. I91T - 1 q_UL.5TED r. _ _ c _ D`.SCPJPTION DATE REV UOrvDfD TO AWG w66ARE Gu. 2 15 I - - I ORIGINAL 12/4120 15 A ROUNDING CONDUCTOR VIA U MPNUFACTURER SUPPLIED nARDu'ARf STRING (I)PV MODULE PER OPTIMIZER 1 21 (1 5)OPTIMIZER5 CONNECTED IN SERIES I -1 4.905 kWetc TOTAL ROOFTOP IIN 3A5EMENT-- - 1 (E)GROUNDING ELECTRODE 5Y5TEM Sheet Title: WIRE AND CONDUIT 5CHEDULE ELECTRICAL CONE) COND COND GND GND GND CONDUIT CONDUIT E5T. DIAGRAM PV System Maximum Voltage Calculation per NEC 690.7(A) TAG CITY 51ZE TYPE QTY SIZE TYPE SIZE TYPE DI5T. heet Number: Local Record Low Temp: i-18 PC Data Source:I LAWRENCE MUNI Voc Tem 25"C- Voc Voc Number of Termperature DCI 2/5TRING AWG#I O PV-WIRE I AWG#6 BARE CU WA WA 10 P DC2 2 AWG#1 0 TH WN-2 I AWG#1 0 THWN-2 3/4" EMT 70 Sheet Sae: Coefficient x Record +1 = Correction Correction x Voc x Modul es in = Corrected Open Low Temp. Factor Factor Series Circuit Voltage AC 1 3 AWG#10 THWN-2 I AWG#8 THWN-2 3/4" EMT 1 O ANSI B - 1 7"X 1111 0.27%/"C x 43°C +1 =1 1.116 1.116 x 64.9 x 1 =I 72.4 VOILS DC AC2 3 AWG#G THWN-2 I I AWG#8 THWN-2 3/4" EMT 1 '0 DESIGN c DRAFTING Br: CONDUCTORSPECIFICATIONS REQUIREDCONDUCTORAMPACITY AMPACITYCNECKp1 CONDUCTORTEMPERATUREDERATING CONDUIT FILL DERATING CORRECIEDAMPACnYCALCULARON a-12- N2 VOLTAGE DROP JOEL HORST H+¢ CI un' CIRCUR TAG pOTT@ _ OPEPaTING m TEMP RAGE ORIGIN DESRNATON rem x = PAOn MPI'Q 3 -TAKEAMPA dC0�� 00 FpP PF P CO,,,",° 11 -1. ." D PEP PFR PGDx PER FPAT P1« DNDVLTGP GFOP xTvoPOP DC3 NCUOx eOx COPPER P90'C AWG R1031ab0 pm s 15.0001 sin1 GES 15.0 ATX,, P1.25 = 188EGEMPAm 18.8 BA <AGOGO RGOROPNFREF NR rEG32 GN 00'Vn 0.1223 Tf� 1p'O.J6zOa mxN/AOPS °z1.000x AMI A 036FA D1p00F=.c30.4 Nn s mps 10ft 0.11% OCiTi]QQOQ���QO D[2 1 Iu1xvEPTEP COPPER ]5'C AWGN30 35 ams 15.00 1 15.DAmozI x 1.15 =':18.8 am 168 Amps < 35.0 pros 32 1 22 54 06] 1 1.00 35 x 0.6]x ].00 13.5 Amps ]On 0.I9% C�S�C1n vl!T V9R CON-RSPECIFICATIONS x REQUIREDCONDUCTORAMPA[nY AMPA[m CNECK pl CONDUCTORTEMPERATUREDERARNG CONWIT FILLOETU\RNG CORRECTED AMPACIWCALCUTATION O�.. VOLTAGE DROP TAG O�RCGt1IN CIRCUIT.... IRCUR[IESIINATON nR TEMP, TPADF °�® 1 ROE _ R.Un POP z25z PFMAX P _ OPmlr ErrvIPONMFxrrG.2..DPEunxG mxDUROP IM F17 = Reviewed E Approved by: SNVEATEPS 6PD.&N(il(a)-NAAMM21'Q 3 EMTE x 335Am16AES m21.0ixl 1 =;21.0Anp.x 1.25 =:M3Pams 26.3GAsros< 35PAasps 1xDC0Ps.o-0 TE32 zDJO21a o>x03LTDP.3L0LLCO3z 35R xoQ!NI x O1p00E AMPACITY=I 32.9An1ps UTY .,_EE 0.21% EH AC2 aC DISCONNECT sPLICEWIn1EKISTINGCONOUCTORS COPPER ]5'C AWGN6 65 pm 21.0 x ] :21.0 apps x 1.25 =26.3 asps 26,3 asps< 65 Anes OOM(. 32 32 0.91 3 100 65 x 0.94 x L. =1 6L3 I, Ion 0.09% I A 1 - I Contractor: .. REVOLU(SUN M�ilsm:w e • i NORTH AVENUE ,-• aBURLINGTON,MA 01803 • • • • • P:(781)270-6555 REQ'D BY:NEC G90.17 REQ'D BY:NEC 690.31(E)(3) REQ'D BY:NEC 705.12(D)(4) REDD BY:NEC 705.1 2(D)(7) �� REQ'D BY:NEC 690.1 4(C)(2) �� www.Mas5arhv5etts.PevoWsun.com APPLY TO: APPLY TO: APPLY TO: APPLY TO: 4 APPLY TO: D15CONNECT5 EXPOSED RACEWAYS,CABLE TRAYS MAIN SERVICE PANEL PV SYSTEM BREAKER PV SYSTEM AC DISCONNECTS PV LOAD CENTERS COVERS OR ENCLOSURES OF JUNCTION BOXES COMBINER BOXES CONDUIT BODY WJ AVAILABLE CONDUIT OPENING Protect: LOPEZ RE51DfNCIf 15 LITTLE ROAD W11I NORTH ANDOVER,MAO 1645 (�` -• •p, •Zy'p� JOB#:MA02_16_0022 gial -• • • • •- .r�rr• [roJect Details: `7[� .0 a &a 4.91 kW5tc,5.00 kW AC 111 orshly-lyft Wow M-1 REQ'D BY:NEC 690._13(e) � REQ'D BY:NEC 690.5(C) REQO BY:NEC 690.54 Engmeermg Approval: APPLY TO: APPLY TO: APPLY TO: PV SYSTEM DC DISCONNECTS INVERTER PV SYSTEM DISCONNECT WOW Q -. iIrDPT1►• FM V T tivil►• a p 3G ^• �� v�U•1�y�yy��rr• • •- Q3 REVISIONS !. V•J • • • Dt G..I ION DATE REV . ORIGINIJ 12/4/2015 A ©%c lama . REQ'D BY:NEC 690.53 REQ'D BY:NEC 69O.35(F) REQ'D BY:NEC 690.5G(C) APPLY TO: APPLY TO: APPLY TO: INVERTER JUNCTION BOXES,COMBINER BOXES PV SYSTEM DISCONNECT DC DISCONNECTS,INVERTERS heel Title: SAFETY PLACARDS heet Number: E2.0 Sheet Slze: ANSI B - 17"x I I" SIGNAGE REQUIREMENTS JOEL HORST�wG BY: 1.)RED BACKGROUND /�[J 2.)WHITE LETTERING CCOe�� O�Opp 3.)MIN.3/8"LETTER HEIGHT 4.)ALL CAPITAL LETTERS OUQ�gq�oOggq 5.)ARIAL OR SIMILAR FONT 6.)WEATHER RESISTANT MATERIAL,PER UL 969 Remewed k Approved by: EH Contractor: E-SERIES SOLAR •ANELS SUNP.QWER� E-SERIES SOLAR PANELS REVOLU(SUN MOU EN-ZGY.FOR IFP MORE ENERGY.FOR UH7 I NORTH AVENUE _ BURLINGTON,MAO 1803 SUNPOWER OFFERS THE BEST COMBINED POWER AND PRODUCTWARRANTY P:(781)270-6555 1 R r z POWER WARRANTY PRODUCT WARRANTY www.Mas5achusdt5.Revo4nun.com HIGH PERFOfUvWNCE&EXCEUENT DURA8IUTY '°°` 1� E0 osx -------- Project: x SERIES o s 10 1s 9a ss o s ro v�a vo u LOPEZ PE51DENCE 19 LITTLE ROAD Mon errumrbw power:95%Tar rant 5 park C.ombWW Power and Pro"d•bd 25 year cwxoee NORTH ANDOVER,MAO 1545 •20.4%efficiency p q%/yr,b poor 25.1 dwt indodw pow"nplautwo mw.° JOB#:MA02_1 6_0022 Ideal ret vvf"�aPoB et ELECTRIC _DATA OPERATING CONDITION AND MECHAMCALDATA Project Details: fiAe�P°O°IDnmight -®_E19320 �74mp•�re-- --_40°C b+BS'C 1 4.91 kW51,c,5.00 kW AC rowed. Ptdnuwl Powe'+(RnomJ 327W 3204V� Wind;2400 Pa,245 kli/msfram a back .High padolmance E20.327 PANa Power7abrarw +5/-0% +5/-0% I Max trod Soar.5400 Pa,550 k8/ms room ! Deliver excellerll pedonnanae In ted weld Avg.Pant E$ede•.Y" 20.4% 19.8% ~Impxt malabnra 25mm d ander lroR at 23 m/+ Engmeermg Approval: conditions,auchashlghremperatures, HIGHEFFICIENCY6 RobdvdrawNmPP1 547V 54.7v Appwcnc• gaNA _ clouds and law ligld.",2,' Generale,more energy per square malar RoNd Current Qarppl 5.98 A 5.86 A Solar Ca16 96 Monad ici a Marmon Can p Proven value CSerltu rastdenttal panels eameA arae sunpght b ekreMetty, Vonage(Voe) 64.9 V 64.B V� Temp•nd Gera F118h�vonsmtsekn bmpend AnR.pelleawe-- Designed for residential rooftops,E Series pmducirg 36%arae paler per panel,'and 60%more energy per She sClrcuR Cwratt)kdpad 6A6 A 6.24 A juneRon Box IPdS Roved panels doli%w dro fookaos,3bo and equore maker art 25 yaaro''' Mar.Sydem Volkg. 1000 V IEC a 600 V UL Conrlaaa• MC4 performance for any bane. Mad.wm Senn Tsar 20A I :�ryame Cbu l black anedisd Adel w HAMA yolk HIGH ENERGY PRODUCTION' PcvnriempCwf. -0.38%/•C Wetgb 18,6 k8—_ Produce more energy per re1ed 1311 Vdbge Tags CoeF. -176.6 mV/•C High year one per(ormonoe delivers 74%more energy per raled Cmmq Temp Cad. 3S oJI%'C TESTS AND Cf1IT01CIQKMdS .j s I Stardom Wb IEC 61215,IEC 61730,LIL1703 watt, This advan age Increases over Woe,pradudrg 20%more -- 1 energy am the first 25 years ro med yaw news.' REFERENCES: am SPR-E20-327 ss a mpmrartahn comenriornl Cloy— 150 90 HSAS 8 001:2 00,6M REVISIONS pont:240W,aPP""•.1.6 mp,15%deripxy, '�. EFTS CompRarlw RoHS,C+HSA518001:2007,1►od beer oescr�vrloN onre rzev 2 PAvok"labs'Suibw•r Shudhv S•dy,•F.6 2013- pV Cycb 3 Typically 7.9%mme emraypor v,dk BEW/DNY fipomirg SurPower gm shy IEC 6y16 OWGiNAL Iv42ois n ' Ydd Repoof Jon 2013. Eng-. I.,pole bear. 4 TwnPaw 0.25%/yr dapodo6on a.I ZAtyrcora.panel Cempeau,7 Sak Spmy Nat IEC 61701 Ward ma Imum aeyrl y) En81""a•d b"P"ilon""^®.'�"8n•d for durohtky. 200 a d-". —Modb 0Wcc1arwn Rab,•swi'awervAdN.paper.Fab Pm lad Pd4.nFk{4�dumd Dagradalion fns looDVb 120Y. a 2013;Jordon,Wk'5udlwwr Ted Report,•NR9.,Od 2012.Engineered for of mold Maw Euray 5•StmNwwer Modula 40-Yew UxM IJIV Sxftwer-hu POW, Ave bbl.Gat 8a 7W,MCS,lR JET.I�AKO,C5q tTC PSEC ._ __., r - Designed b deliver consWeal,trolblafrae 11 ox 9% >w1 P.Rand Wan - 2013.Uedrd lib b 99 our of lOD power opaofel0 M mon than 70%af energy over a very brg hlelime.4' 100x ,dad 6O of d 2600 pude T�rd'n Photon IgaroSanoL rah 2012 Designed for dumblliy ro% 35%. 7 8%mmei wow th n the wave.of th.top 10 pard companies 1.0W The SunPoaer M=eat Solor Cell b the .ox In 2012(151 pwW4102 mnwordes),Phobn 4arrmllonA Mad'2013. beet Tale: onycell Wit ona sold copper founfation. To% � 41Compvadwith LheJap 15manaraaaa &MPaAWWa=*Ro�ww. � 1046 M. PV MODULE VhW*mpervloustothe conoslonand 60% 99SSm�maaAman' apply.Seewwra*f-A—" DATA SHEET sacking that degrade Convenrwnd 50% _ _--- _ 105 of top 8 panel montioduaawae tested by%who%r 6E,'A° pbne(544 0 5 10 15 20 25 Modrb OmabinyW6dM Wide Rgron,'rvsb 2013. heel Number: Year 11 Canpu•dw dh go nortd�control pad.Attie 25+OrimbTOy .I D ,Q 41 Ranked Infamhoferdurabtpylast."" 10% ..._._,_ o00, 48 mm"i 1559 mm� warporlreb201a 100%prover motmined N Atlas 25' Mabwlnw Kuh ,pY yy��w 12 Sbndmd imtCoWiNon(1000wAr'Inadionm AM 14%277. cwrprdunwvoPMDurowyW."1 a% ._. Pawor0wahTamp t 1 13Barad"nwaapeofmmandpmwvdumdurirppodu6m sheetsre: 1 Nou9h"'ad t m,nn. ANSI B - I T x I I" 6% -- Dnawdanen �yn� -�F096 Arwn>ea Wan, DE51GN 4 DRAFTING BY: /t r 4% .-,. .. sow tawugh,and JOEL HOR5T Spam)Rerp- 2% .. Hiahp•rfmmava 1��C1p1"1C1CpCCTs� Y1 i'�Aar�.tm�n.a0ma rl+vvn...�,apa..�mmmjramk.me.ew.x.►a roma. UrJ�o��UaCdoo Y 0% fvao•ddab,..�.wd.ddwbdr.a row tt ad,dq.ad tamawmalar6adve L.fe.r•we4d nada awwmue.n�aaa�N,rdr,�.6xe+w�wam•°'� uoNaamr.r«va.�4mwiue..w.a..a.o.d�d �U4rA�gyOCq/o� Mo�4dSualrOrPpe' Md1o6^shdJdb/idmdnrw•dFabdvyM/we� SEL ISO /1 sunpnvroraorp.00m ar+ Renewed 4 Approved by: Eh Contractor: Single Phase Inverters for North America REVOLUSUN solar_ solar ® o —. SE3000A-US/SE3800A-US/SE5000A-US/SEGOGOA-US/ ® ® • SE7600A-US/SEIOOOOA-US/SE1140OA-US I NORTH AVENUE BURLINGTON,MA 01803 SE3=A-US I SE3BODA-US I SESOODA-US I SE6000A-US I SE7600A-USI SE30000A-US I SE11400A-US P:(75 1)270-6555 OUTPUT SolarEdge Single Phase Inverters . Nominal ACV,welOmPat 3000 36to 5000 fi0W 7600 9980@208V 114W VA WWW.Ma55achU5Ctt5.RCVOlu5Un,C0In ............................. 5400®2O8V ]o8M®2oBV Mac AC Power Output 3301] x350 EDW- - .tl350 12810 VA For North America . ...................... ...................... 5454.[:s9y......... a.9s�9. . ......... -'AC Out Voltage Min-Nam:Max.'" J J 183-208-229 Vac SE3000A-US/SE3800A-US/SE5000A-US/SE6000A-US/ . .................................................................................................................................................... AC OUIPat Voltage MIm.......Mac•' J J J J J J J SE7600A-US/SE10000A-US/SE11400A-US 211-zoo-z6avaa +" ACf a rc Mn N Max .I-*i 60-60.5 with 111 counu ettln 5]60 60.5 Ha Pro t 24 2oav as @ 2oev W..Connmwus Ompnr Curmm lzs '6 2s 314zs A LOPE2 RESIDENCE ............................................ I..............I...?3. =R9y...I................I...............,I...?2�.?9uY...I............................. 19 LITTLE ROAD GFDI Threshold 1 A .._.......................................................................................................................................................................... NORTH ANDOVER.MA 01845 r bol" h4amrodn,Iua"ah ProronJon,Cnunu inn arable mresnpm: re: vM JOB#:MA02_I G_0022 I INPUT - "' as NL simlun nC Pmver STC) ¢0511 Slof1 fi7561 Rlllfl 10)50 1351Y1 T535f1 W Protect Details: 1 ........................1.................................................................................................................................. ........ • atC� , ramtarmm-lens,any!w�ueg..................................................................Y!....................................................................... ........................ I ...............................................................................wD..............................................................vac.... 4.91 kWstc.5.00 kW AC �dsu'._-i Nom.DC Input ValrnyC.............................................................325�O 206V(3i0 240V................................................Vdc.... 16.5 @ 208V 33 @ 208V • S• Max.Input Current'" 9.S ,- 13 18 23 141- Adc,. r. I ......I.15; 24oV I....... ......I..0.5 40V I........ ............................................ n meenn A 1 _ Max.Input 511mk Orcuit Cunem 45 adc.,.. E g g pprova0 ........................................................................................................................................................................ 2 ` Reverse-volare vratecllon .........................................................Yes .,........I...................... ........ I Graund.FaultlwlaHon Detekdon GOOka SenaiHYAy............. ............................................ ............................................................................................................ Masimum Invar4•r EHiclaricY 9%.'/ 98.2 98.3 98.3 9tl I­ ....... 9tl 96 X GCC WciBhtad Clficiency--- --- 97.5 97.5 @ 208V 97 @ 208V ...... 96 9].5 97.5 97.5 96 Ni hmmn Power Cnnsum tin <2.5 <4 W n ADDITIONAL FEATURES Support W CommuniwHon Interlaces RS185,85232, .............................................................................................................. ........................ _.... —I ,. Mvenue Grade Data.AN51[12.3OPHonal"' ........ .................................................................................................................................................................. t Rapid Sh,nShmdown-N[[2014690.12 FuncHorwllty enabled when SolarCdge rapid shmtlown kit is Installed"' STANDARD COMPLIANCE SafetY..........................................................................Ut17a1�U11f998,U11996 i CSA 22:?.................................................... i .... .......................... .......... „ G d Commcnpn Standards IEEE154] STALo part]5 class I PCC B t? INSTALLATION SPECIFICATIONS REVISIONS AC out d i U /AWG 34'millilnurl/]G 6AWG 3/4'mmilnwn 83AWG DESCKIPrION DATE REV ....................... ..../............!............................... ................W... .1........... ........... y' UCInWt rW ti /p ul stdngs/ S/4`minim.6AwG sU n8s/ ORIGINAL 12/4/2015 A ASG 3/4'mirumum/1-2strn8s/166 AWG. ...... „' ..,,,...;6ANlG,,,, - .... ........................... I - Oimenslons with Safety Switch """ ..tNpWs41.........- 30.5.12.5.]2/]1 335x164 775 3 5 2 o......... ......................... ....... .. ......................................... 9 / K.6o min -wghjat.w(tn safe!yswi�cn.......................six/z3:?...............................?:7.1.??:?... ...........MA/.4u.i............. ii�iu�ai.. .... Cmlmg natural eonvecmn ana lnterwl Fan:(nserreplaceame) tan Jus ......................... . .......... The best choice for SolarEdge enabled systems ........... "w�;e........................................................................................... ..pR1 FPpts1.. ........... u <.. daA .................................................................................................................................................................. Integrated arc fault protection(Type 1)for NEC 2011690.11 compliance Min:Max OperaWr6lmroerawre -]3to+140/-25 to•6040 to+60 versionavadable"9 'F/'C heat Title: Ran6P...................................................................................i..................................................................... p Fp pp Superior efficiency(98%) "' 1 V �NVLt\TLI\ ProtttHan RaHn.n...-,,. ..................NEMA 3R -Small,lightweight and easy to install on provided bracket ................... ........ ..................................... .......................................................................... , PPN��waE�r�w DATA SHEET -Built-in module-level monitoring oiuY�:so—sk�oc"w� -Internet connection through Ethernet or Wireless ni0" "� ' heat Number: -Outdoor and indoor installation D2.=0 - Fixed voltage inverter,DC/AC conversion only 1�. - Pre-aFixed voltage Safinverter, Switch for faster installation beet Sae: -Optional-revenuegrade data,ANSI C12.1 �sunsPEc 0 ANSI B - 17"x I III a USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-ISRAEL www.solaredge.us 4 E51GN 4 DRAFTING BY: JOEL tKJP.ST �.-�-' Ct�oaCCe�aCCpo CCidCCU0�000 oe��e:�aaogogvl SER �. Rewewed a Approved by: Eli Contractor. solar - © 0 w(_) Solar ' 0 0 � SolarEdge Power Optimizer REVOLU�SUN Module Add-On for North America �are,.6ma a.aaa. P300/ P320/ P400/ P405 I NORTH AVENUE BUKUNGTON,MAO 1803 SolarEdge Power OptimizerP30P370 P400 P405 P:(781)270-6555 lar 64sNlmedules) (lur hghpower Ilur T2&96ca11 (IarthWfam I 6o-zeI .duks) modues) modules) www.Mas5Whu5etls:Revolu5lm.com Module Add-On For North America INPUT Rated input DC Power"1............................300.......................320.......................40a.......................405..... W P300 P320 P400 / P405 Absolute maximum mPMt Voltage V d8 80 125 Vdc e ..(VPc at lowest temperature).............................................. .. ................................................................ ............. ® MDPT Operon&Range 8-48 .......................8:80....... ...12:S:105 Vdc s .. ........................................... ..... ' . Max u Short Circ n Current(Ise) 10 11 30 Adc 1rc� ..... ...............................................................I................................................ .......... i ? Pro ecc Maximum DC In ut Current 12.5 13.75 12 5 Adc J ...................................................................... ........... .. © Maximum ElfiaegcY r cs,: v "'... : Wel hied Ethaency645 ... LQ IE * ,4, .......................................... % LITTLE ROA_ DD..._.. .................................................. .......% .............................................................. NORTH NDITVEMA0 Overvolta a Category 11JOBN.MA02_16 0022 OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) > .. r Maximum Output Current............. ..... .......... .......... 60.... ................is...................... Maximum Output Voltage ...1 ..........................Adc Vdc Protect Details 85 OUTPUT DURING STANDBY OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) 4.91 kWstc,5.00 kW AC © Safety Output Voltage per Power 1 Vdc Optimizer STANDARD COMPLIANCE Engmeenng Approval. .............. - FCC PartlS Class B,.IEC63000-6-2,)EC61OW-6.3 .......,. ..................................................................... .............. .... .. .............................. .Safety............ ....... IEC621091(dass,11 safety),.UL3741............................. .......... ............ ......................................... .. .. t �181t� RoHS Yes 4 � INSTALLATION SPECI FICATI0NS �""`" Max mum Allowed 5 tem Volta a 1000 Vdc .. ...!...................Ys............6....................... ............Phos..and a lmi........................................ ... ... _' Cnm anhle inverters All SnlarEd a Sin IP Phase and Three Phase IIfVPriPrt / 128x 152x35/ 128x 152 z48/ Dtmensions(W xLzH) 128x 152 x 27.5Sz 5.97x 1.08 Sx5.97x1.37 5x 5.97 x 1.89 mm in ........................ ................................................................................................................................................. Weight(mdudmg rabies).....................................770/}:? ......930.(LOS..,............930/2.05 gr/.Ib.... .. ........................ .. ............ . •- ,Input Connector .....I........................................MC4 Compatible...... '•, '• Output Wire Type/Connector Double Insulated MC4 Compatible - -r Out ut Wae Le h 095/30 } 1.2/39 m ft .,. .Operating Temperatpre Range,.,.,.,, ,,,,,-40..+85.(.40_:+185..,.... ... ,;C/'F.,., REV1510N5 ........ ............. • ; Protection Rating ......... ......... ......... ,,,...._-IP68%.NEMA6P .............. DE5CMMOn DATE Rev ` Relative Humidity .......... .....................................0 100 76,,,,,. ORIGINAL 12/4/2015 A �� '� �. - -°'Nu05iCporarMtlM moOWe MOEWa of DD to�Snpouvrloleran[a rllowN. PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE 208V THREE PHASE 480V A SOLAREDGE INVERTERm Minimum String Length g 10 18 _(PPwer.OPNmlzers). ...................................................................................................................................... PV ower optimization at the module-level Maximum String Length P P (Power 0 t mixers 25 25 50 ............P.......)....................... ......................................................................................................... Up to 25%more energy Maximum Power per String 5250 6000 , „......12750 W Sheet Title:pT T,,t-7Cp .................g..... ................ Yes...... ......... ............................. �I 1 IIVIIGLI� Parallel Strings of Different Lengths Superior efficiency(99.5%) or Orientations .................................................................................................................................................................... Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading nenx+uewmmmawuswnn Dxwwwwxn/Drao.o o.,[.vmu DATA SHEET — Flexible system design for maximum space utilization — Fast installation with a single bolt D6. Next generation maintenance with module-level monitoring Module-level voltage shutdown for installer and firefighter safety Sheet 5¢e: ANSI B- 17" x I I" TIN USA GERMANY - ITALY FRANCE JAPAN CHINA - ISRAEL - AUSTRALIA www.solaredge.US JOEL HOR5T CC o0poeaoOp` ��F1e�Q�ugC.Cis EPISOLA Renewed k Approved by: Eh 11 r � Contractor: REVOLU(SUN I NORTH AVENUE BURLINGTON,MA 01803 140° P:(781)270-6555 www.Ma5wchu5dt5.Revolu5un.com JEJOB OPEZ RESIDENCE 1 9 LITTLE ROAD ANDOVER,MA O 1845 #:MA02 I G0022 177tc, 5.00 kW AC Engineenng Approval: REVISIONS DE5CRMON DATE I REV ORIGINAL 12/4/2015 A heel Title: OPTIMIZER 5HEET Shcet Number: heet 5,— AN51 B - 17"x I I" E51GN 4 DRAFTING BY: JOEL HORST VOl^pC�C9 gu'�OUUMo50q ISO AR Reutewed<Approved by: EH The Commonwealth oj'Massacltusetts _ Department of Industrial Accidents Office of Investigations ' 1 Congress Street,Suite 100 Boston, MA 02114-2017 jwvw.nwss gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name(Business/Organization/Individual): Northeast Solar Services Inc Address:I North Ave Suite A City/State/Zip:Burlington/MA/01803 Phone#:781 -'270-6555 Are you an employer?Check the appropriate box: Type of project(required): 1. ✓❑ I am a employer with.12 4. ❑ I am a general contractor and I employees(full and/or part-time):* have hired the sub-contractors 6: E]New construction 2.❑ I am a sole proprietor orpartner- listed on the attached sheet. 7. F1 Remodeling ship and have no employees These sub-contractors have g. ❑Demolition an work in for me in aci employees and have workers' g Y tY 9. ❑Building addition [No workers'comp. insurance comp. insurance.$ required.] S. ❑ We area corporation and its 10.❑Electrical repairs or additions 3.❑ I am ahomeowner doing all work officers have exercised their 11.❑Plumbing repairs or additions myself [No workers'comp: right of exemption per MGL 12.❑Roof repairs insurance required.]t c. '152;it(4),and we have no employees. [No workers' 13. ✓ OtherSolar PV comp. insurance.required.] .*My applicant that checks box#1 must also fill out the section below showing their workers'compensation,policy information. t Homeowners who submit this affidavit indicating they are doing all work and.then hire outside contractors must submit a new affidavit indicating such. #Contractors that check this box must attached an additional.sheet showing the name of the subcontractors and state whether or hot those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I ani attemployer tlint is providing workers'compp'etrsatiort iiLvurance for my employees: Belmv is flee policy and job site information. Insurance Company Name:Federated Mutual Insurance Company Policy#or Self-ins.Lic.#:9884086 _ Expiration Date:1/08/2016 Job Site Address: 11 t _ City/State/Zip:A AJ6y r Attach a copy of the workers'compensation policy declaration page(showing"the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. Ido leer cerci under the o mand penaldesgUgd that the. orm don provided above is true and correct Si e: 1 ---- � Phone#:781-270-4899 Official use only. Do not write in this area,to be completed by city or town ofif ciaL City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector Contact Person: Phone#: DATE(M MIDWYYYY) '4 "® CERTIFICATE OF LIABILITY INSURANCE 01/08/10'15 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW,THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: if the certificate holder is an ADDITIONAL INSURED,the polWies)must be endorsed.If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsements. PRODUCER CONTACT CLIENTCONTACT CENTER FEDERATED MUTUAL INSURANCE COMPANY HOME OFFICE:P.O.BOX 328 PA�C No Ext:888.933.4949 FAX No):507446-4664 OWATONNA,MN 55060 EDpAIEss:CLIENTCO ACTCENTER FEDINS.COM INSURERS AFFORDING COVERAGE NAIC A INSURER A.FEDERATED MUTUAL INSURANCE COMPANY 13935 INSURED 297.673.6 INSURER B: NORTHEAST ELECTRICAL INC,NORTHEAST SOLAR SERVICES INC INSURER C: 1 NORTH AVE BURLINGTON,MA 01803 INSURER D: INSURER E: INSURER F. COVERAGES CERTIFICATE NUMBER:54 REVISION NUMBER:2 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE S L UBR POLICY NUMBER POLICY EFF POLICYMMIDDrimm iDERP LIMITS GENERAL LIABILITY EACH OCCURRENCE $1.000,000 X COMMERCIALOENERALUABILITY DAMAGES RENTED $100,000 CLAIMS-MADE N OCCUR MED EXP(Any one person) EXCLUDED A Y N 9884064 12/31/2014 12/31/2015 PERSONAL&ADV INJURY $1,000,000 GENERAL AGGREGATE $2,000,000 OEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OP AGO $2.000.000- POLICY PO- LOC AUTOMOBILE LIABILITY MBINED SINGLE LIMIT $1,000, 0 X ANY AUTO BODILY INJURY(Per person) A AU OS AUTOSNED U�D Y N 9884085 12/31/2014 12/31/2015 BODILY INJURY(Per acddenQ HIRED AUTOS NON-OWNED ROPERTY DAMAGE AUTOS X UMBRELLA LIAR X OCCUR EACH OCCURRENCE $5.000.000 A EXCESS LIAB CLAIMS-MADE N N 9864067 12/31/2014 12/31/2015 AGGREGATE $51000,000 DED RETENTION WORtCERSCOMPENSATION X WCSTATU• OTH- AND EMPLOYERS'LIABILITY Y/N TORY LIMITS ER ANY PROPRIETORIPARTNERIEXECUTIVE I I E.L.EACH ACCIDENT $1;000,000 A OFFICERIMEMBER EXCLUDED? u N I A N 9884086 12/31/2014 12/31/2015 -- (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $110001000 If yea,describe under El DISEASE-POLICY LIMIT DESCRIPTION OF OPERATIONS below 1 $1•000.000 DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(Attach ACORD 101,Additional Remarks Sdkadule,U more space Is required) THE CERTIFICATE HOLDER IS AN ADDITIONAL INSURED SUBJECT TO THE CONDITIONS OF THE ADDITIONAL INSURED BY CONTRACT ENDORSEMENT FOR GENERAL LIABILITY. THE CERTIFICATE HOLDER IS AN ADDITIONAL INSURED SUBJECT TO THE CONDITIONS OF THE ADDITIONAL INSURED BY CONTRACT ENDORSEMENT FOR BUSINESS AUTO LIABILITY. CERTIFICATE HOLDER /�` 1 j CANCELLATION ©� 6 v t'Y� �� 2 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE © 1988-2010 ACORD CORPORATION.All rights reserved. ACORD 26(2010105) The ACORD name and logo are registered marks of ACORD t [1 � ♦ Ifs ` ' .� �' l 9 T r 4 gl L 1 'Yi a h, w �..r