Loading...
HomeMy WebLinkAboutMiscellaneous - 200 Marblehead Roadi Harry Bottrquin �LD Martleridge Rd. APPLICATION FOR SEWAGE DISPOSAL I BTALIATION HEALTH DEPARTMENT - NORTH ANDOVER, IHSS. I hereby make application for a permit for a sewage disposal installation at Marble ge Road "I will install this system in ac- cordance with all the laws of the Commonwealth of Massachusetts and regulations of the Board of Health of the Town of North Andover. Further, I will construct the house sewer of bell and spigot pipe, the minimum diameter being 4 inches, and will maintain a minimum grade of 1% until 10 feet pre- ceding the septic tank, where the grade shall not exceed 2%. I will install a con- crete septic tank of .750 gales, in size. A manhole (s) permitting easy cleaning will be provided with removable cover (s) of iron or concrete within 12 inches of the ground surface. I will provide subsurface disposal field with 4 inch perforated or open jointed pipe and laid in a series of trenches, the bottom of which will pro- vide a minimum of 160 4&W(square) feet of effective absorption area. The pipes will be laid on a 6 inch layer of washed gravel or crushed stone ranging in size from 3/4 to 1-1/2 inches (dia.) and the pipes will be surrounded by similar material to a height of 2 inches above the crown of the pipe. The joints of these pipes will be protected from clogging and before filling the trench, 2 inches of gravel or stone 1/8" to 1/4" (dia.) will be placed over the course gravel or stone. The disposal field will be installed at a grade of 4 to 6 inches/100 feet. No single tile line will exceed 100 feet in length and in any case, two lines of tile will be installed. A minimum of 6 feet will be maintained between the center lines of the disposal field trenches and the average depth of trench shall not exceed 36 inches. No part of the installation will be less than 100 feet from any private water supply, 25 feet from any stream, 20 feet from any dwelling or 10 feet from any property line. I further agree not to cover any portion of this installation until approved by the inspection officer, as provided below, and to incorporate any additional requirements that may be attached to the permit. Plot Plans must be submitted with application. DATE April 271 1960 ig ture of Appli t I hereby issue the above permit for the Board, of Health of the Town of North Andover, Massachusetts. DATE_ S' ature of Health Agent I have inspected the uncovered system indicated above and find everything done as described. DATE , �k u � 1p Percolation Test 1 min* Soil Gravel Garbage Grinder 4, Na�_ OAK - Signature o nspecting Officer April 30, 1960 Miss Mary Sheridan R• N. Health Agent Board of Health North Andover, Mass' Dear Miss Sheridan: order to determine the d An e�.nation was made as requested in sal of sewage on the of the soil for the subsurfaJ• disPOBo ' suitability � building site of Harry Marbleridge R° eneral The land in g is high. d a 1 -minute area is of gravel content an The subsoil in the conducted• percolation test was © a11on concrete Septic tank be It is recommended that a 75Eget of drain PiPe- installed together with 160 line truly yours, Very am J. Dr co]l Willi 4a WJD:hd • K • u