Loading...
HomeMy WebLinkAboutMiscellaneous - 26 VILLAGE GREEN DRIVE 4/30/2018 (2)DATE: 603-893-4260 NEW ENGLAND RADON, LTD. 1-800-637-2366 373 Main Street Salem, New Hampshire 03079 LABORATORY ANALYSIS RESULTS, 9 October 1, 1988 RADON RESULTS FOR: Terry Nevans Village Green Condos North Andover, MA 01845 TEST SITE: D j e,rmoun 26 Village Green Drive North Andover, MA 01845 Code No.Cp i/L Location 6739 4.3 Basement The result of this measurement indicates that there is 'the potential that you may have a radon problem. The EPA recommends that follow-up tests be conducted when the screening test result is 4 pCi/L or above to give you a better idea of the average radon concentration in your home. In most cases the screening measurement is not a reliable measure of the average radon level to which you and your family are exposed. It is -however, an effective way of separating those houses which may have a problem from those that do not. We recommend that you make follow-up measurements before ,you make any decisions about whether to undertake major efforts to correct the potential problem. Follow-up measurements should be made in at least two lived in areas of ,your home. If your home has lived-in areas on more than one floor, ,you should make measurements in a room on each of the floors. An example is to take a mesurement in the living' -room of the first floor and another in a second -floor bedroom. Because of the seasonal variation of radon levels, measurements should be made during each of the seasons. If you.have a private well, we also recommend that you test your water for radon contamination.